Loading...
HomeMy WebLinkAboutNCS000580_MONITORING INFO_2019100271,71-.,o STORMWATER DIVISION CODING SHEET NCS PERMITS PERMIT NO. (�JLS 0() 0 u DOC TYPE 0 FINAL PERMIT MONITORING REPORTS ❑ APPLICATION ❑ COMPLIANCE ❑ OTHER DOC DATE 90 I "I (0 YYYYMMDD DUKE ENERGY® PROGRESS File: Mayo 12520-R NC Department of Enlironmental Quality Division of Water Qua ity ATTENTION: Central Files 1617 Mail Service Cen er Raleigh, North Carolin i 27699-1617 September 27, 2019 E�la �l-V OCT O'P fi;9 Mayo Steam Plant Duke Energy Progress 10660 Boston Road Roxboro, NC 27574 C1=NTR,� ... 1-ES DLJRc1 :�T'IC:�''' Subject: 15A N. C. Admin. Code 213.0506 Mayo Electric Generating Plant National Pollutant Discharge Elimination System Stonnwater Permit NCS000580 Stonnwater Discharge Outfalls 002, 006A and 010 Monitoring Report Dear Sir or Madam: In accordance with Part III. Section E2 of NPDES Stormwater Permit Number NCS000580, enclosed is the year 3, August 2019 Stormwater Discharge monitoring report for Outfalls 002 and 010 for Duke Energy Progress, LLC. - NPDES Stormwater Permit Number NCS000580. To note, Outfalls 002 and 010 are in tiered status and there were no rain events for August during normal business hours. I certify-, under penalq of law, that this docuunent and all attachments were prepared under my direction or supervision in accordance with a system desigrned to assure that qualified personnel properly gather and evaluate the information submitted. fused on m'y inquiry of the person or persons rvho manage the system, or those persons directly responsible for ��athering the information, the infin-mation submitted is, to the best 4my knowledge and belief; true, accurate, and complete. 1 am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Please contact Ms. Lori Tollie at (336) 854-4916 if there are any questions concerning the data in this submittal. Sincerely, Tom Copolo- Manager Mayo Electric Generating Plant Enclosures LPW/Ipw STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number: NCS000580 SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY NAME Mayo Electric Steam Plant PERSON COLLECTING SAMPLE(S) Joseph Heath Slade CERTIFIED LABORATORY(S) Duke, Shealy Lab# 248 & 329 Mayo Plant Lab Lab #_5064_ Part A: Specific Monitoring Requirements COUNTY Person PHONE NO. (336) 597-7398 SIGNATURE OF PERM ITTEE OR DESIGNEE REQUIRED ON PAGE 3. Outfall 'No. Date 1 Sample Collected i '00400 39516 01119 00981 71901 01092 - 00530 Total Rainfall'. pH; PCBs Copper' Total- Selenium Total Mercury Total = Zinc -Total TSS Non=Polar Oil & Grease mo/dd/ r inches I Standard 99A m m m m MgA m Benchmark 6-9. Detected 0.010 0.056 N/A' 0.126 100 15 002 NO FLOW See Comments 010 NO FLOW See Comments Outfall Additional Priority Pollutant Metals' 00999 01079 00978 00998 01113 011t8 01074 01114 01268 00982 No. Boron Ag' As Be Cd' Cr' Ni' Pb' Sb TV- mg/1 mg/l mg/1 mg/l mg/l mg/l mg/l Eng/I mg/1 mg/1 Benchmark N/A(monitor only) 0.0003 0.34 0.065 0.003 0.9 0.335 0.075 0.09 NIA (monitor only) 002 010 Form SWU-247, last revised 21212012 Page I of 3 Footnotes: Permit # NCSOOOS80N(Part II Paae 7 of 15) 4. For each sampled measureable storm event, the total precipitation must be recorded. An on -site rain gauge is required. Where isolated sites are unmanned for extended periods of time, a local rain gauge reading may be substituted for an on -site reading. 5. These parameters shall be monitored only if coal or coal ash is transported through the drainage areas of these outfalls during the semi-annual monitoring period in Table 2. Footnotes: Permit # NCS000580 ( Part II Page 9 of 15 ) 1. Hardness- dependent. Benchmark based on translation of dissolved value into total recoverable with an assumed hardness of 25 mg/I and a total suspended solids (TSS) concentration of 10 mg/I. 2. Values above the North Carolina water quality standard for mercury (12 ng/1) should be noted on the DMR but do not trigger Tier responses. Concentrations infield blanks or method blanks associated with the sample may be subtracted from the results for that sample, as long as all documentation of the adjustment is provided with the DMR. 3. If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6- 9. Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? yes _X_no (if yes, complete Part B) Part B: Vehicle Maintenance Activity Monitoring Requirements Outfall No. Date Sample Collected 50050 00556 00530 00400 Total Flow (if applicable) Total Rainfall Oil & Grease (if appl.) Non -polar O&G/TPH - (Method 1664 SGT-HEM), if appl. Total Suspended Solids pH - New Motor Oil Usage mo/dd/ r MG inches MO mgA unit gaurno Form SWU-247, last revised 21212012 Page 2 of 3 Comments: • Outfall 0111: Tier One: No rain events for August during normal business hours. • Outfall 002: Tier Two: No rain events for August during normal business hours. STORM EVENT CHARACTERISTICS: Date Total Event Precipitation (inches): Event Duration (hours): (only if applicable — see permit.) (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): (only if applicable — see permit.) Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of t _ O4�e'1 f ti (Date) Form SWU-247, last revised 21212012 Page 3 of 3 T fe DUKE ENERGYe PROGRESS File: Mayo 12520-R NC Department of Environmental Quality Division of Water Quality August 27, 2019 Mayo Steam Plant Duke Energy Progress 10660 Boston Roar! Roxboro, NC 27574 ATTENTION: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 'SEP a-3 zags r1c ,E Subject: 15A N. C. Admin. Code 2B CE'iTR,gt, .0506 D� ��C1,;ILE5 Mayo Electric Generating Plant National Pollutant Discharge Elimination System Stormwater Permit NCS000580 Stormwater Discharge OutfalIs 002, 006A and 010 Monitoring Report Dear Sir or Madam: In accordance with Part III. Section E2 of NPDES Stormwater Permit Number NCS000580, enclosed is the year 3, July 2019 Stormwater Discharge monitoring report for Outfalls 002, 006A and 010 for Duke Energy Progress, LLC. - NPDES Stormwater Permit Number NCS000580. 1 certify, under penalty of law, that this docurncrrt and all attachments were prepared raider nry direction or supervision in accordance with a systear designed to assure drat qualified personnel properly �>ather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible forgathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, card complete. 1 am aware that there are, significant penalties for submitting false infonnatinn, including the possibility of fares and imprisonment for knowing violations. Please contact Ms. Lori Tollie at (336) 854-4916 if there are any questions concerning the data in this Submittal. Sincerely, Tom Copolo- Manager Mayo Electric Generating Plant Enclosures LPW/Ipw STORM WATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number: NCS000580 SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY NAME Mayo Electric Steam Plant PERSON COLLECTING SAMPLE(S) Joseph Heath Slade CERTIFIED LABORATORY(S) Duke, Shealy Lab# 248 & 329 _iMayo Plant Lab Lab #_5064_ Part A: Specific Monitoring Requirements COUNTY Person PHONE NO. (336) 597-7398 SIGNATURE OF PERMITTEE OR DESIGNEE REQUIRED ON PAGE 3. Outfall No. Date + Sample Collected 00400 39516 01119 00981 71901 01092-' 00530, Total Rainfa114 pH' PCBs Copper' Total Selenium Total iVlercury- Total Zino Total TSS Non -Polar . Oil & Grease mo/dd/ r inches Standard RgA m m m m m m Benchmark 6-9 Detected 0.010 0.056 NIA' 0.126 100 15 002 07/23/19 @ 13:46 2.03 6.53 <0.40 0.0144 <0.001 0.0000143 0.018 237 <5.0 006A 07/23/19 @ 11:55 2.03 6.47 0.00459 <0.001 0.00000855 0.007 5 <5.0 010 07/23/19 @ 10:15 2.03 6.33 0.0153 <0.001 0.0000416 0.028 324 <5.0 Outfall Additional Priority Pollutant Metals' 00999 01079 00978 00998 (11113 01118 01074 01114 01268 00982 No. Boron' Ag' As Be " Cd' Cr' Ni' Ph' Sb TV mg/I mg/I mg/l mg/I mg/I mg/I mg/I mg/I mg/I mg/) Benchmark N/A(monitor only) 0.0003 0.34 1 0,065 0.003 0.9 0.335 0.075 0.09 N/A (monitor only) 002 <0.05 <0.0002 <0.001 <0.001 <0.001 0.0155 0.00718 0.0038 <0.001 <0.0002 t106A <0.05 <0.0002 <0.001 <0.001 <0.001 <0.001 0.00138 <0.001 <0.001 <0.0002 010 <0.05 <0.0002 0.00109 <0.001 <0.001 0.0221 0.01 t3 0.00838 <0.005 1 <0.0002 Form SWU-247, lass revised 22/2012 Page 1 of 3 Footnotes: Permit # NCS000580 (Part II Paae 7 of 15) 4. For each sampled measureable storm event, the total precipitation must be recorded. An on -site rain gauge is required. Where isolated sites are unmanned for extended periods of time, a local rain gauge reading may be substituted for an on -site reading. 5. These parameters shall be monitored only if coal or coal ash is transported through the drainage areas of these outfalls during the semi-annual monitoring period in Table 2. Footnotes: Permit # NC5000580 (Part Ih Page 9 o1 15 ) 1. Hardness- dependent. Benchmark based on translation of dissolved value into total recoverable with an assumed hardness of 25 mg/I and a total suspended solids (TSS) concentration of 10 mg/l. 2. Values above the North Carolina water quality standard for mercury (12 ng/1) should be noted on the DM R but do not trigger Tier responses. Concentrations infield blanks or method blanks associated with the sample may be subtracted from the results for thatsample, as long as all documentation of the adjustment is provided with the DMR. 3. If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6- 9. Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? _ yes _X_no (if yes, complete Part B) Part B: Vehicle Maintenance Activity Monitoring Requirements Outfall No. Date - Sample Collected 50050 00556 00530 00400 Total Flow (if applicable) Total Rainfall Oil & Grease (if appl.) Non -polar O&G1TPH (Method 1664 SGT-HEM), if appl. Total Suspended Solids pH New Motor Oil Usage mo/dkr MG inches mgA mgn unit aUmo Form SWU-247. last revised 212!?012 - Page 2 of 3 Comments: Footnote 2: Permit # NCS000580 (Part II Pa,,,e 9 of 15) • Mercury value for outlall 002 on 07/23119 was 14.3 ng/l which is over the North Carolina water quality standard for Mercury of 12 ng/l_ • Mercury value for outfall 010 on 07/23/169 was 41.6 null which is over the North Carolina water quality standard for Mercury of 12 nu/1. • Copper values for 002 and 010 were over the benchmark value of 0.010 mg/I. • TSS values for 002 and 010 were over the benchmark value of 100 mg/l. • Revision made to permit to include new 002. Permit was amended and signed on 3/21/19. STORM EVENT CHARACTERISTICS: Date _06/1812019-06/19/2019 Total Event Precipitation (inches): 2.03 Event Duration (hours): _9.5_ (only if applicable — see permit.) (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): (only if applicable — see permit.) Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Forin SWU-247, last revised 21212012 Page 3 of 3 (Signature of (Date) Form SWU-247, Iasi revised 21212012 Pa-ce 4 of 3