Loading...
HomeMy WebLinkAboutNCS000571_MONITORING INFO_20200302MTO STORMWATER DIVISION CODING SHEET NCS PERMITS PERMIT N0. DOC TYPE ❑FINAL PERMIT MONITORING REPORTS ❑ APPLICATION ❑ COMPLIANCE ❑ OTHER DOC DATE ❑ P � u u � v YYYYMMDD (n DUKE ENERGY February 25, 2020 NC Dept. of Environmental Quality Attention: Central Niles Division of Water Resources 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Duke Energy Carolinas, LLC Duke Energy Carolinas, LLC Rogers Energy Complex 573 Duke Power Road Mooresboro, NC 28114 RFr,;=1N/=D MAR 02 2'10 GEN I r"L i-ILE,9 D" SECTION NPDES Stormwater Discharge Monitoring Report for: Rogers Energy Complex - NCS000571 — Cleveland / Rutherford Counties Year 5 — Period 1 DMR Submittal — <lanuary 2020 DMR Dear Sir or Madam: In accordance with Part III, L(2) of the above referenced NPDES Stormwater permit.. the original and one copy of the Stormwater Discharge Outfall (SDO) monitoring report for part of the Year 5 — Period 1 (January) are attached. A summary of analytes reported at concentrations above the permit benchmarks for the January 2020 sampling event is provided below: Permitted Outfall Date Sampled Analyte Reported Concentration Permit Benchmark SWO04 1/24/2020 Zinc 0.231 rn T/1 0.126 mg/1 SW005 1/24/2020 Zinc 1 0.135 m r/l 1 0.126 mg/l Please direct any correspondence or questions concerning the Rogers Energy Complex NPDES Stormwater Program to Steve Hodges at (828) 657-2339. "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Sincerely, c David P Barnhardt General Manager 11 Rogers Energy Complex - Cliffside Stearn Station Fossil/1-lydro Generation - Carolinas Coal Generation Electronic w/attachment: Robert Wylie Andrew Stroud USPS Tracking Number: 7017 1450 0000 3876 8436 Raleigh Central Office (original plus one copy) 5TORMWATER DISCIIARGE OUTFALL (SDO) MONITORING REPORT Permit Number NCS000571 SAMPLES COLLECTED DURING CALENDAR YEAR: 2020 ('Phis monitoring report shall be received by the Dkkian no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY NAME Roger's Energy Cum))Iex - Clitfside Steam Station (:Ol1N"n* RIITHERFORD PERSON COLLECTING SAMPIX(5) leremv Vanwvk - Cardno & Steve Hodges - Duke PHONE NO. 028) 657-2339 CERTIFIED LABORATORY(S) Dukc Encrg_} Lab # 248 Sheah Environmental Sera ices, Inc. Lah # 329 SIGNATURE, OF PERNIFFT'EE OR DESIGNEE REQUIRED ON PAGE, 3 Part A: Specific.%lonitoring Requirements Outfall No. Date Sample Collected 50050 00400 01077 01002 01022 01012 0027 01034 Total Flow (if app.) Total Rainfall pl I Silver, Total (as AU) Arsenic, Total (as As) Boron. Total (as B) Beryllium, Total (as lie) Cadmium, Total (as Cd) Chromium, Total (as Cr) moldd/vr MG inches SI m L m L m L mg/1, m L m L S%V(K)1 1/2412020 NIA 1.22 7.2 <0.0002 0.00115 <0.05 <0.001 <0.001 <0.001 SWOt14 1/24/2020 NIA 1.22 7.2 SN1005 1112412020 NIA 1.22 7.3 SWO15 - 13 1/2412020 N/A 1.22 <0.0002 0.00107 <0.05 <0011 <0.001 <0.001 SW017 i12412020 N/A 1.22 7.2 <0.0002 <0.001 <0.05 <0.001 <0.001 <0.001 SWOINA 1/24/2020 N/A 1.22 7.8 <0.0002 0.00139 <0.05 <0.001 <0.001 0.00167 SWO01 W112020 NIA 0.6 S%VO04 1/31/2020 NIA 0.6 Outfall Date 01042 01067 01051 01097 01147 01059 01092 71900 CO530 No. Sample Collected Copper, Total (as Cu) Nickel, Total (as Ni) Lead, Total (as Pb) Antimony, Total (as Sb) Selenium, Total (as Se) Thallium, Total (as Ti) Zinc, Total (as Zn) Mercury,'fotal Method 1631 E : Solids, Total Suspended- Concentration mo/ddl yr m L m L Mgt[, m L mgIL m L m L n L Mgt], S1►'001 1/24/2020 0.00107 <0.001 <0.001 <0.001 <0.001 <0.0002 0.124 2.27 <2.5 nolel SNvFD04 1/24/2020 0.0087 <0.001 0.231 6.63 24 note I SWOOS 1/24/2020 0.00265 <0.001 0.135 2.91 30 note 1 S«1015 - 13 1124/2020 0.Ix0136 0.00143 <0,001 <0.001 <0.001 <0.0002 <0,005 1.61 8.4 note 1 SW017 1/24/2020 <0.001 <0.001 <0.001 <0.001 <0.001 <0.0002 0.007 3.43 18 note 1 SWOINA 1/24/2020 0.00208 0.00154 <0.001 <0.001 <0.001 0.0002 0.010 5.92 18 note I SW001 U31/2020 8.6 S%N'004 1/31/2020 3.1 Form SWU-247, fast revised 7/6/2016 Permit Number NCS000571 Page 1 of 1 Qutfall Dale 00556 No. Sample Collected Oil & Grease molddlyr MIYO. SWO01 112412010 SN'004 1124/2020 <5 SN1005 1/24/2020 <5 SWO15- 13 1/24/2020 SN'017 1/24/2020 SWO18A 112412020 SWOM 1/31/2020 SN'004 113112020 Note l - TSS samples were received at the lab with ice with in the sample container. TSS will be resampled at nett opportunity. Benchmark ezceedances include Zinc, Total (as Zn) at SW005 Benchmark mceedances include Zinc. Total (as Zn) at SR'004 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil pet month? yes (if yes, complete Part B) Part B: %rehicle Maintenance Activity Monitoring Requirements 110 Outfall Date 50050 00556 00530 00400 Total Flow (if Total Rainfall Oil & Grease (if Nan -polar Total Suspended pH New Motor Oil No. Sample Collected applicable) appl.) O&CITPH Solids Usage (Method 1664 SGT•HEA1), if appl. molddlvr MG inches M90Inagn unit atlmo I STORM EVENT CHARACTERISTICS: Mail Original and one copy to: Date OI12412010 Division of Rater Quality Total Event Precipitation (inches): 1.22 Arm Central Files Event Duration (hours): (only if applicable — see permit.) 1617 Mail Scrvice Center Raleigh, North Carolina 27699-1617 (if more than one storm event was sampled) Date 0113112020 Total Event Precipitation (inches): 0.6 F%ent Duration (hours): (only if applicable — see permit) "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquin of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are signk ' ant penalties for submitting false information, including the possibility of fines and imprisonment for knowing vialalian,E' } z7 z 12.E 6 (Signature of Permittee) (Date) ' Permit Number NCS000571 Form SWU-247, last revised 7/6/2016 Page 1 of 1