Loading...
HomeMy WebLinkAboutNCS000096_COMPLETE FILE - HISTORICAL_20191106STORMWATER DIVISION 60DING SHEET- -... RESCISSIONS. PERMIT NO. DOC7YPE COMPLETE FILE -HISTORICAL DATE OF RESCISSION YYYYMMDD A ALBEMARLEG Kings Mountain Facility 348 Holiday Inn Drive Kings Mountain NC 28086 November 1, 2019 Central Files - Stormwater 1617 Mail Service Center Raleigh, NC 27699-1617 RE: Semiannual Stormwater Discharge Summary Report Albemarle — Permit NCS000096 Kings Mountain, Cleveland County, NC Certified Mail 7016 2070 0000 1239 6927 Dear Sir or Madam: RECEIVED NOV 0-6 2019 CI NYRAL FILES DWR SECTION Please find attached a Semi -Annual Stormwater Discharge Outfall (SDO) Monitoring Report for the Albemarle facility located in Kings Mountain, North Carolina. This report was prepared in accordance with the site's General Stormwater Permit effective on November 1, 2009 and covers the Monitoring Period of May 2019 — October 2019. Based on the sampling results summarized herein, it appears that the site has met its benchmark goals during the reporting period, with one exception: A pH of 9.20 was measured at outfall 005A on October 13, 2019, slightly higher than the' benchmark range of 6.0 — 9.0 units. An additional representative rain event was monitored on 10121/19, which produced results within the benchmark range. In accordance with Tier One requirements as outlined in our permit, we performed a facility inspection on October 16, 2019 and conducted other investigations to determine the probable cause of this event. We have seen higher pH at this outfall in the past and believe the primary cause was calcium carbonate "mud" byproduct migrating from the indoor loading bay onto the adjacent outdoor concrete pad. In response to the prior event, we implemented measures to improve our containment of this mud, including engineering controls to reduce migration, and a cleaning schedule for the outdoor concrete pad. These measures have largely been effective, and we believe they will continue to be adequate under normal circumstances. We believe the primary cause of the 10/13/19 pH result was that the rain event of October 13 occurred after an unusually long drought — it was the first representative rain event since August 27, 2019 (47 days). This prolonged time allowed material to accumulate in cracks and crevices on the concrete pad. Our inspection and investigation did not reveal any other obvious factors that would have contributed to the elevated pH. In addition, subsequent monitoring of a representative rain event on 10/21/19 (and a non -representative rain event on 10/16/19), showed pH within the AALBEMARLE 0 Kings Mountain Facility 348 Holiday Inn Drive Kings Mountain NC 28086 benchmark range. For these reasons we believe our current management practices are effective. However,,we have undertaken a three-phase project to further reduce the possibility of calcium carbonate byproduct migration from the area where it is produced to areas that can affect stormwater. • Phase 1 — completed September 2019 — provide a closed tank to receive process washes, which eliminates oversplash in the indoor collection bay and migration out of it to the concrete pad • Phase 2 — planned for 1 Q 2020 — install equipment to dry and pelletize the calcium carbonate material. The calcium carbonate material is currently produced as a sludge which makes containment within the indoor bay more challenging • Phase 3 — consider installing conveyances and a silo to receive and transfer dried calcium carbonate material, rather than discharging it to an open dumpster Should you have any questions or need additional information related to this data, please con ct John Kuhn at 704-734-2708. J nKVa SE M STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number NCS000096 FACILITY NAME Albemarle, Kings Mountain PERSON COLLECTING SAMPLE(S) -. D v- �� ^ CERTIFIED LABORATORY(S) 7 _ Lab # 140 Lab # Part A: Specific Monitoring Requirements SAMPLES COLLECTED DURING CALENDAR YEAR: 1)1019 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Cleveland PHONE NO. (704) 739-2501 aREO ATURE OF PERMITTEE OR DESIGNEE UIRED ON PAGE 2. Outfall No. Date Sample Collected 50050 50030 00400 Total Flow if a Total Rainfall Total Suspended Solids pH mo/dd/yr MG inches m /l unit �o ,. t9 a.C- "P_ __7 .Ot 1 ops Fr f r3 1 0.31 to , 5 f 61. � G .aU oc> f +3 r O. Ofv _ S f lJ.1 `7.59 Egos O. 30 D .9 g.-7-7 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? ()yes (if yes, complete Part B) {� fir (0bL0llk e�vE.%} "A's 4%Z l.rS 111 vQJ SJS n n Part B: Vehicle Maintenance Activity Monitoring Requirements Outfall No. Date Sample Collected 50050 00556 00530 00400 Total Flow (if applicable) Total Rainfall Oil & Grease (if appl.) Non -polar O&GITPH (Method 1664 SGT-HEM), if appl. Total Suspended Solids pH New Motor Oil Usage mo/ddl r MG inches mg/1 mo unit al/mo Form SWU-247, last revised 611212015 Page I of 2 STORM EVENT CHARACTERISTICS: Date id 13 I dt Total Event Precipitation (inches): Q•Sf Event Duration (hours): S (only if applicable — see permit.) (if more than one storm event was sampled) Date r0 i 'i Total Event Precipitation (inches): o -9S Event Duration (hours): 7 (only if applicable — see permit.) Mail Original and one copy to: Division of Energy Mineral and Land Resources Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant penalties for submitting false information, including t>e possibility of fy)1s W imprisonment for knowing violations." (Signature of Permittee) (Date) i3 +`l ii tss %0`t 00 P_LR `' — r\c^ Ivat thy, IV'`I V 3cD e S-e,-C:1-A rl n o.�9 •� V S-7 11r- Form SWU-247, last revised 611212015 Page 2 of 2