Loading...
HomeMy WebLinkAboutNCG050346_COMPLETE FILE - HISTORICAL_20180323STORMWATER DIVISION CODING SHEET RESCISSIONS. PERMIT NO. DOC TYPE 5� COMPLETE FILE - HISTORICAL DATE OF RESCISSION ❑ p� �� U3� J YYYYMMDD Find Permit Related Permits � E Waiver Outfall Comments ' History r Inspections [ Incidents r Enforcements r Violations Details 1 Details 2 Billing Events Reg. Activities Eff. Guidelines Affiliations Reviewers Permit: tJCG050346 Version: 3.0 Status: Inactive Event Type 1 Event Date Due Date Comment Last Updated By, UpdateD... lit rescinded 12/12/2018 FRO (M.Lawyer) has confirmedthat ... Bethany.Georg... 1121121201 8 iit.Annual Fee it Annual Fee 1110612018 11/0712017 1210V2018 12101/2017 --'FRO{tv1. Lawyer) has coniirmed�thatcompany is out of business and no longer operaBng in this building. The operation has been replaced by a new company that will appyfor a separate permit. Efforts to contact the previous . :owners have not been successful. nit Annual Fee 11/0212016 12t011_016 iit.Annual Fee iitAnnual Fee 1110312015 1110612014 1210112015 12/01/2014 lit Annual Fee Ti0512013 1210112013 bimsprod.cron 11/0512013 lit issued 06/01/2013 —__ bim_sprod.cron___ O610A/2013 Details... cation received 05/21/2013 bimsprod.cron 0/2212013 ication reviewed 05/21/2013 bimsprod.cron 0512212013 matic Renewal Started 05/21/2013 oimsprod.cron 05122/2013 Remove nit Drafting Initiated bimsprod.cron 05122/2013 ewal due bimsprod.cron 05122/2013 nit Annual Fee 1 11210112019 1 bimsprod.cron 11/0612018 Compliance Events History <Back t_Je�l- Finish CI e Joyner, Melissa From: Joyner, Melissa Sent: Friday, March 23, 2018 11:17 AM To: 'pfj412@gmail.com' Subject: Fex Straw Manufacturing Inc. Rescission Request Form Attachments: Rescission Request Form.pdf Importance: High Dear Mr. Payerl: This email is In reference to the former Fex Straw Manufacturing, Inc. facility which is no longer in operation, located at 191 Magna Blvd., in Lumberton, Robeson County, North Carolina. Please complete the attached Rescission Request Form and mail it to the address on the form. This form is required to be submitted because the facility's NPDES Stormwater General Permit NCG050346 no longer needs to be maintained since the facility has ended its operations. Thank you in advance for doing so. Please feel free to contact me with any questions at (910) 433-3384. Kind Regards, Melissa Joyner Melissa Joyner Environmental Specialist Division of Energy, Mineral and Land Resources Department of Environmental Quality (910) 433-3384 office melissa.joyner@ncdenr.gov 225 Green Street, Suite 714 Fayetteville, NC 28301-5043 .''Nothing Cornpares� Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Violations I r Details 1 r Details 2 r(`�=Billtng.:.. r Events .Reg -Activities r Eff. Guidelines r Affiliations r Reviewers I Permit: CGD50346 Version: Status' dve, Facility IFex Straw Mlanufacluring Billing Contact ompkins, Brenda Ftnd'Per... Find Qrg... Ftaint.. County Address 1: 191 Magna Blvd Title: -� obeson Fee Category: tormwater4astewaier discharge COCs " Address 2. "�- l Phone: 910j 671-4141 . Bill Monih:' Orig Billed: 12222005 - City: umbeiton • State: NC. ZIP: 12 - December, P - - _- @) Normal 0 Fast Track .C) Express Review. Invoice Type Period Year 'Fe-riodBegin IPeriod End Billing Montti I DueDate I invoice # I Amount I Paid Balance Status. Permit Annual Fee 2017 12/01/2017 11/3012018 December 12/07/2017 2017PR009898 S100.00 50.00 Overdue Permit Annual Fed 2016 12/01/2016 11130/2017 December ' ` 12102/2016 ° 2016PR009890" <b160.OQ l &4`9'9� $j 9p] Overdue', Permit Annual Fee 2015 12/012015 11/302016 December 121032015 2015PR010264 5100.00 15100-00 1M_jMPajdPermit Annual Fee 2014 12/012014 111302015 December 12/062014 2014PR010138 $100.00 $10000 Permit Annual Fee 2013 12/01/2013 11/302014 December 12/052013 2013PR009798 $l90_09J Permit Annual Fee 2012 12/012012 111302013 December 12/062012. 2012PR010952 $10000J $1¢090J Permit Annual Fee 2011 12/012011 11(302012 December 12/02/2011 2011PR009944 $100.00 $100.00Permit Annual Fee 2010 12/012010 111302011 December 12/092010 2010PR011075 Reprint Invoice Enter Payments... Maintain Invoice.. - Back Next ,_ Finish 3�.��n�So{�rnhl3�y'en� 3.�1•!8 �iSSa� p�,iNlzQ�mw`b T e(' owf a Sc rCG�rFeT '[Yav"� y wc�s also adlc Va entif v �,rer e.i„V21� NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY INVOICE Annual Permit Fee II I2I III16 II II II III9II8I I9I 0 II Overdue This annual fee is required by the North Carolina Administrative Code. It covers the administrative costs associated with your permit. It is required of any person holding a permit for any time during the annual fee period, regardless of the facility's operating status. Failure to pay the fee by the due date will subject the permit to revocation. Operating without a valid permit is a violation and is subject to a $10,000 per day fine. If the permit is revoked and you later decide a permit is needed, you must reapply, with the understanding the permit request may be denied due to changes in environmental, regulatory, or modeling conditions. Invoice Number: 2016PR009890 Permit Number: NCG050346 Robeson County Fex Straw Manufacturing Brenda Tompkins Fax Straw Manufacturing Inc 191 Magna Blvd Lumberton, NC 28360 Annual Fee Period: 2016-12-01 to 2017-11-30 Invoice Date: 11Y0212016 Due Date: 12/0212016 Annual Fee: $100.00 Notes: 1. You may pay either by mail with check/money order OR by electronic payment (eCheck or Credit Card)., 2. If payment is by check/money order, please remit payment to: NCDEQ - Division of Energy, Mineral and Land Resources Attn: Stormwater Billing 1612 Mail Service Center Raleigh, INC 27699-1612 3. If payment is electronic, please see httb://deg.nc.gov/stormwater-epayments to pay electronically. Payments by eCheck will debit your checking account. Credit card transactions will incur a convenience fee. 4. Please include your Permit Number and Invoice Number on all correspondence. 5. A $25.00 processing fee will be charged for returned checks in accordance with North Carolina General Statute 25-3-512. 6. Non -Payment of this fee by the payment due dale will initiate the permit revocation process. 7. Should you have any questions regarding this invoice, please contact the Annual Administering and Compliance Fee Coordinator at 919-707-9220. (Return This Portion With Check) ANNUAL PERMIT INVOICE Invoice Number: 2016PR009890 Permit Number: NCGO50346 Robeson County Fax Straw Manufacturing Brenda Tompkins Fox Straw Manufacturing Inc 191 Magna Blvd Lumberton, NC 28360 III2I III1III II II II D I9II8II9I II II Overdue Annual Fee Period: 2016-12-01 to 2017-11-30 Invoice Date: 11/2/2016 Due Date: 12/2/2016 Annual Fee: $100.00 Check Number: NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY INVOICE Annual Permit Fee II I2I III1I II II I I II II I9I I8I I9II8I II Overdue This annual fee is required by the North Carolina Administrative Code. It covers the administrative costs associated with your permit. It is required of any person holding a permit for any time during the annual fee period, regardless of the facility's operating status. Failure to pay the fee by the due date will subject the permit to revocation. Operating without a valid permit is a violation and is subject to a $10,000 per day fine. If the permit is revoked and you later decide a permit is needed, you must reapply, with the understanding the permit request may be denied due to changes in environmental, regulatory, or modeling conditions. Invoice Number: 2017PR009898 Permit Number: NCGO50346 Robeson County Fax Straw Manufacturing Brenda Tompkins Fax Straw Manufacturing Inc 191 Magna Blvd Lumberton, NC 28360 Annual Fee Period: 2017-12-01 to 2018-11-30 Invoice Date: 11/07/2017 Due Date: 12/07/2017 Annual Fee: $100.00 Notes: 1. You may pay either by mail with check/money order OR by electronic payment (eCheck or Credit Card). 2. If payment is by check/money order, please remit payment to: NCDEQ - Division of Energy, Mineral and Land Resources Attn: Stormwater Billing 1612 Mail Service Center Raleigh, NC 27699.1612 3. If payment is electronic, please see htte:lldeo.nc.gov/stormwater-eoayments to pay electronically. Payments by eCheck will debit your checking account. Credit card transactions will incur a convenience fee. 4. Please include your Permit Number and Invoice Number on all correspondence. 5. A $25.00 processing fee will be charged for returned checks in accordance with North Carolina General Statute 25-3-512. 6. Non -Payment of this fee by the payment due date will initiate the permit revocation process. 7. Should you have any questions regarding this invoice, please contact the Annual Administering and Compliance Fee .Coordinator at 919-707-9220. (Return This Portion With Check) IIIIIIIIIIIIII IIIIIIIIIIIIII * 2 0 1 7 P R 0 0 9 8 9 8 ANNUAL PERMIT INVOICE Overdue Invoice Number: 2017PR009898 Permit Number: NCG050346 Robeson County Fax Straw Manufacturing Brenda Tompkins Fax Straw Manufacturing Inc 191 Magna Blvd Lumberton, NC 28360 Annual Fee Period: 2017-12-01 to 2018-11-30 Invoice Date: 11/7/2017 Due Date: 12/7/2017 Annual Fee: $100.00 Check Number: Georgoulias, Bethany From: admin@ncdenr.gov Sent: Thursday, June 27, 2013 10:41 AM To: SVC DENR.stormwater Subject: Confirmation for Renewal of DWQ Stormwater NPDES General Permit ** Do not reply to this e-mail as it is from an unmonitored mailbox. ** Thanks for renewing your permit using our on-line option. No further action is necessary. The new General Permit is available for printing from our website at littp:Hportal.ncdenr.0r�z/web/wq/ws/su/ . If you have questions, please contact Bethany Georgoulias at bethany.eeor,ouliasn.ncdenr.gov phone (919) 807-6372 or Bradley Bennett at bradlev.bennettnncdenr.eov phone (919) 807-6378. If you forgot to print your Certificate of Coverage you can resubmit the data and print another copy. This COC is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated October 15, 2007 (or as subsequently amended.) The General Permit authorizes discharges of stormwater and specifies your obligations for discharge controls, management, monitoring, reporting, and record keeping. Please review the new permit to familiarize yourself with all of the changes. Parts III and IV contain the Standard Conditions, including Compliance and Liability, Reporting, Monitoring and Records requirements; Operation and Maintenance obligations; and Definitions. Your facility has six months from receipt of the COC to update its Stormwater Pollution Prevention Plan (SPPP) to comply with changes in SPPP requirements. Other changes are effective immediately. Please note that Tier 3 Actions (if applicable) are triggered by four benchmark exceedances beginning on the effective date of the renewal permit and do not count prior exceedances. Please visit our website above to review the new General Permit carefully. Your coverage under the General Permit is transferable only through the specific action of DWQ. This permit does not affect the legal requirements to obtain other permits which may be required by DENR, nor does it relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. CONFIRMATION DETAILS Permit Number: Effective Date: Expiration Date: Organization Name: Facility Name: Admin Region: County Name: Regulated Activity: Receiving Stream Name: Receiving Stream Class: Basin: Facility Address: NCG050346 6/ 1 /2008 5/31 /2013 Fex Straw Manufacturing Inc Fex Straw Manufacturing Fayetteville Robeson Apparel/Leather/Rubber/Printing/Misc manufacture Jacks Branch WS-IV;Sw Lumber 191 Magna Blvd Facility City: Facility State: Facility Zip: Affiliation Type: Fax Number: Work Phone Number: First Name: Middle Name: Last Name: Email: Lumberton NC 28360 Owner (910)671-1138 (910)671-4141 Brenda Tompkins bethany.aeoreoulias,,ncdem-.aov 10 Michael F. Easley, Governor William G. Ross Jr., Secretary Noah Carolina Department of Environment and Natural Resources Coleen H. Sullins; Director Division of Water Quality September 25, 2008 Brenda Tompkins Fex Straw Manufacturing 191 Magna Blvd Lumberton, NC 28360 Subject: COMPLIANCE EVALUATION INSPECTION Fex Straw Manufacturing Inc Fex Straw Manufacturing NPDES Stormwater General Perm it-NCG050346 Robeson County Dear Ms. Tompkins: On September 22, 2008, 1, Michael Lawyer.from the Fayetteville Regional Office of the Division of Water Quality, conducted a site inspection at the Fex Straw Manufacturing facility located at 191 Magna Blvd in Robeson County, North Carolina. A copy of the Compliance Inspection Report is enclosed for your review. Your time and assistance provided during the inspection is greatly appreciated. Stonnwater from this facility drains to Jacks Branch, a Class WS-IV;Sw stream located in the Lumber River Basin. The site visit and file review revealed that the subject facility is covered by NPDES Stormwater General Permit-NCG050346. Accordingly, the following observations were noted during the Division of Water Quality inspection: 1) Stormwater Pollution Prevention Plan (SPPP) A Stonnwater Pollution Prevention Plan (SPPP) has been developed, recorded, and properly implemented. Yes ■ No ❑ 2) Qualitative Monitoring Qualitative monitoring has been conducted and recorded in accordance with permit requirements. es ■ No ❑ Other Observations: Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. Nail Carolina ,11Vnlurally North Carolina Division of Water Quality 225 Green Street, Suite 714 Fayetteville, NC 28301-5043 Phone (910) 433-3300 Customer Service Internet: www tc,vateroualitv.ore Fax (910) 486-0707 1.877-623-6748 An Equal OpponunitylAffrmative Action Employer- 50% Recycled110% Post Consumer Paper Please be advised that violations of the NPDES General Permit are subject to a civil penalty assessment of up to $25,000 per day for each violation. If you or your staff has any questions, comments, or needs assistance with understanding any aspect of your pernut, please do not hesitate to contact me at (910) 433-3329. Sincerely, Michael Lawyer Environmental Specialist Enclosure cc: FRO=Surface Water.Protect�7 N S-Assista e & Compliance Oversight Unit DWQ Central Files Compliance Inspection Report Permit: NCG050346 Effective: 06/O1/08 Expiration: 05/31/13 Owner: Fex Straw Manufacturing Inc SOC: Effective: Expiration: Facility: Fex Straw Manufacturing County: Robeson 191 Magna Blvd Region: Fayetteville Lumberton NC 28360 Contact Person: Brenda Tompkins Title: Office/Finance Manager Phone: 910-671-4141 Directions to Facility: Exit 17 off 1-95, NW on NC72 for -3.5 miles, left on Lowe Rd. for -0.2 miles, right on Magna Blvd. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): On -site representative Brenda Tompkins Phone: 910-671-4141 Related Permits: Inspection Date. 09/22/2008 En. Ti e: 12:45 Exit Time: 02:35 PM Primary Inspector: Mike Lawyer Phone: 910-433-3300 E 3329 40'p,.rc-.l : Belinda S Henson Phone: 910-433-3300 ExSJ2T Reason for Inspection: Routine Inspection Type: Compliance Evaluation 3324� Permit Inspection Type: Apparel/Printing/Paper/Leather/Rubber Stormwater Discharge COC Facility Status: ■ Compliant p Not Compliant Question Areas: ®Storm Water (See attachment summary) Page: 1 Permit: NCGO50346 Owner - Facility: Fex Straw Manufacturing Inc Inspection Date: 09/22/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Inspection conducted with time and assistance provided by Ms. Brenda Tompkins, Office/Finance Manager. Reviewed the facility's Stormwater Pollution Prevention Plan (SPPP), which is well detailed and easy to follow. A minor revision was discussed with Ms. Tompkins concerning the new Qualitative (Visual) Monitoring schedule and requirement that it be performed after a representative storm event. Monitoring records were available from previous years of permit coverage. After the SPPP and records review, a tour of the facility was conducted both inside and outside. Facility has a'perimeter ditch that conveys stormwater from the property at two outfalls both located adjacent to Magna Blvd, one at the entrance to the facility and the other near the compost pile. At the time of inspection, facility appeared to be in full compliance with the conditions of the NCG050000 general stormwater permit. Page:2 Permit: NCGO50346 Owner • Facility: Fox Straw Manufacturing Inc Inspection Date: 09/22/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ D D D # Does the Plan include a General Location (USGS) map? ■ D n D # Does the Plan include a "Narrative Description of Practices'? ■ D D D # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ n D D # Does the Plan include a list of significant spills occurring during the past 3 years? ■ D # Has the facility evaluated feasible alternatives to current practices? ■ D D n 4 Does the facility provide all necessary secondary containment? D D ■ D # Does the Plan include a BMP summary? ■ D D D # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ D D D # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ D D D # Does the facility provide and document Employee Training? ■ D D D # Does the Plan include a list of Responsible Party(s)? ■ D D D # Is the Plan reviewed and updated annually? ■ D 0 D # Does the Plan include a Stormwater Facility Inspection Program? ■ D D D Has the Stormwater Pollution Prevention Plan been implemented? ■ D D D Comment: All liquid material storage tanks are located indoors except for a diesel tank, which holds less than 660 gallons, but is double -walled and under a breezeway roof. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ D D D Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? D D ■ D # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? D D ■ D Comment: Vehicle and equipment maintenance is performed by an outside contractor who takes away all used oil. Also, less than 55 gallons of new motor oil is used per month, which waives the analytical monitoring requirement. Permit and Outfalis Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ D D D # Were all outfalls observed during the inspection? ■ D D D # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ Page: 3 Permit: NCG050346 Owner - Facility: Fex Straw Manufacturing Inc Inspection Date: 09/22I2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine At Has the facility evaluated all illicit (non stormwater) discharges? m L 0 fl Comment: Facility has two outfalls, both located adjacent to Magna Blvd. Page:4 O July 17, 2008 Brenda Tompkins Fex Straw Manufacturing Inc 191 Magna Blvd _ Lumberton, NC 28360 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality Subject: NPDES Stormwater Permit Coverage Renewal Fex Straw Manufacturing COC Number NCG050346 Robeson County Dear Permittee: In response to your renewal application for continued coverage under stormwater General Permit NCG050000 the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater General Permit. This permitis reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated October 15, 2007 (or as subsequently. amended.) The following information is included with your permit package: • A new Certificate of Coverage • A copy of stormwater General Permit NCG050000 • A copy of a Technical Bulletin for the General Permit • Five copies of the Discharge Monitoring Report (DMR) Form • Five copies of the Qualitative Monitoring Report Form The General Permit authorizes discharges of stormwater only, and it specifies your obligations with respect to stormwater discharge controls, management, monitoring, and record keeping. Please review the new permit to familiarize yourself with all the changes in the reissued permit. . The more significant changes in the General Permit since the your last Certificate of Coverage include the following: • Permit cover page - Coverage is expanded to include industrial activities similar to the categorically identified industries. • Part. I Section A - This part explains that the No Exposure Exclusion from permitting option may be available to the permittee. • Part II Section A - Several minor expansions and clarifications of the required content of the Stormwater Pollution Prevention Plan have been added. Please be sure that your plan is updated to comply with the new requirements. • Part It Section B - Qualitative monitoring must now be conducted during a representative storm event. • Part II Section B - The permittee is required to keep a written record of his response to problems identified by his qualitative monitoring observations. • Part II Section C - For facilities with vehicle maintenance activities using more than 55 gallons of new motor oil per month, new provisions require that discharges from the vehicle maintenance areas be sampled twice per year, and that the sampling results be compared to new numerical benchmark values. (The previous cutoff concentrations have been eliminated.) • Part II Section C - For facilities with vehicle maintenance activities using more than 55 gallons of new motor oil per month, new provisions require the permittee to execute Tier One and Tier Two response actions, based on the first benchmark exceedence (Tier One) and the second consecutive benchmark exceedence (Tier Two). Tier Two requires that the permittee institute monthly monitoring instead of twice -per -year monitoring, until three consecutive monitoring events show no benchmark exceedences. • Part II Section C - This part contains a new provision that four exceedences of any particular benchmark will trigger increased DWO involvement in the permittee's stormwater management and control actions. DWQ may direct the permittee to apply for an individual permit, or may direct the implementation or installation of specific stormwater control measures. o ` NhCarolina .1 ahrrally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service Internet. h2o.encstate.nc.uslsulstoonwatechtml 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-9612 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer- 50% Recycled110% Post Consumer Paper Permit Reissuance Letter — Permit NCG050346 Page 2 Your coverage under the General Permit is transferable only through the specific action of DWQ. This permit does not affect the legal requirements to obtain other permits which may be required by DENR, nor does it relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Bill Diuguidof the DWQ Stormwater Permitting Unit at (919)807-6369. Sincerely, for Coleen H. Sullins cc: DWQ Central Files Stormwater Permitting Unit Files FayettevilleRegional Office STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG050000 CERTIFICATE OF COVERAGE No. NCG050346 STORMWATER DISCHARGES NATIONAL POLLUTANT. DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Fex Straw Manufacturing Inc is hereby authorized to discharge stormwater from a facility located at Fex Straw Manufacturing 191 Magna Blvd Lumberton, NC Robeson County to receiving waters designated as Jacks Branch, a class WS-IV;Sw waterbody in the Lumber River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, and VI of General Permit No. NCGO50000 as attached. This certificate of coverage shall become effective July 17, 2008. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day July 17, 2008. for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission W A rF/ 0 Michael F. Easley, Governor 9 William G. Ross Jr, Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality December 22, 2005 ®ENR-FRO Ms. Brenda Tompkins JAN 0 5 2006 Fex Straw Manufacturing 191 Magna Boulevard ®WQ Lumberton, North Carolina 28360 Subject: General Permit No. NCG050000 Fex Straw Manufacturing, Inc. COC No. NCG050346 — Robeson County - ---- -- ---- — --..._ — Dear Ms. Tompkins: In accordance with your application for a discharge permit received on November 21, 2005, we are forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated May 9, 1994 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be . required by the Division of Water Quality or permits required:by the Division of Land Resources, Coastal Area Management Act or any other federal or local governmental permit that may be required. . If you have any questions concerning this permit, please contact Bethany Georgoulias at telephone number (919) 733-5083 ext. 529. Sincerely, ORIGINAL SIGNED BY KEN PICKLE Alan W. Klimek, P.E. cc: Fayetteville Regional Office Central Files Stormwater Permitting Unit Files N""o��n Carolina �vaturally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service Internet: h2o.encstate.nc.us 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-2496 1-877-623-6748 An Equal Opportunity/ARumalive Action Employer— 50% Recycled110% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCGO50000 CERTIFICATE OF COVERAGE No. NCGO50346 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended,- - Fex Straw Manufacturing, Inc. is hereby authorized to discharge stormwater from a facility located at Fex Straw Manufacturing, Inc. 191 Magna Boulevard Lumberton Robeson County to receiving waters designated as an unnamed tributary to Jacks Branch, a class WS-IV Sw water_ in the Lumber River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, and VI of General Permit No. NCG050000 as attached. This certificate of coverage shall become effective December 22, 2005. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day December 22, 2005. ORIGINAL SIGNED BY KEN PICKLE for Alan W. Klimek, P.E., Director Division of Water Quality By the Authority of the Environmental Management Commission LOCATION MAP: Latitude:34°39'7' NCG050346 Longitude:79°6'3" Facility r> �y�=5 >i County: Robeson, NC Fex Straw Location F' ' _ Stream Class: WS-1V Sw Manufacturing, Inc. Receiving Stream: UT to Jacks Branch Sub -basin: 03-07-51 (Lumber River Basin) cffolc Z MALE 1ad,000 Re: NOI from 17ex Straw Manufacturing - NCG050346 Subject: Re: NOI froth I'ex Straw Manufacturing - NCG050346 From: Belinda Henson <Belinda.l-lenson a ncmni1.net> Date: Mon, 19 Dec 2005 16:32:26 -0500 To: Bethany Gcorgoulias <bcthany.georgoulias a nenIail.nct> Bethany, Thanks for your email reminder. I actually had this on the top pile of my to do list. I do not see any issues with this facility. You can move forward with the COC. Thanks and Merry Christmas. Belinda Bethany Georgoulias wrote: Belinda, I just wanted to touch base before leaving for the holidays later this week since I'll be out for a little while. If there are no concerns with this facility, I can issue this COC before the Christmas holiday, but if you'd like us to hold it longer for any staff review, no worries. Thanks, BG -------- Original Message -------.- Subject: NOI from Fex Straw Manufacturing - NCGO50346 Date: Fri, 09 Dec 2005 13:41:34 -0500 From: Bethany Georgoulias<bethany.georgoulia.s@ncmail.net> To: Belinda Henson <Bel inda. Henson@ncmail.net> Hi, Belinda, We've received an NOI from Fex Straw Manufacturing, Inc. for the GP for Miscellaneous Manufacturing (NCGOS) for their facility in Lumberton-. The site manufactures straw for horse bedding (? I'd never heard of that. before! Those are either some posh horses, or I just never thought about how horses need bedding :P). The site discharges stormwater to a UT to Jacks Branch, classifies WS-IV Sw waters. Attached is a copy of the NOI for the appropriate staff. Does the FRO have any concerns with issuing a COC to this facility? Thanks, BG Belinda S. Henson Regional Supervisor NC DENR-Division of Water Quality Surface Water Protection Section Fayetteville Regional Office (910)486-1541 1 01,1 12/19/2005 4:51 PM O Brenda Tompkins 191 Magna Blvd. Lumberton, NC 28360 Dear Ms. Tompkins: ®ENR—F °"' Michael F. Easley Governor NOVnC V 2 8 2005 William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources n Ii�1I �� Alan Klimek, P.E. 1� Acting Director Division of Water Quality November 22, 2005 Subject: Application No. NCG500629 Fex Straw Manufacturing Inc. Robeson County This is to acknowledge receipt of the following documents on November 21, 2005: X Completed Notice of Intent (Application form), Engineering Proposal (for proposed control facilities), X Request for certificate of coverage _X_ Application processing fee of $80.00. X Engineering Economics Alternatives Analysis, Engineering Plans and Specifications Local Government Signoff, Source Reduction and Recycling, Interbasin Transfer, Service and repair receipts. The items checked below are needed before review can begin: Completed Notice of Intent (Application Form), Engineering proposal (see attachment), Application Processing Fee of $50.00, Delegation of Authority (see attached), Biocide Sheet (see attached), Engineering Economics Alternatives Analysis, Engineering Plans and Specifications Local Government Signoff, Source Reduction and Recycling, Interbasin Transfer, Other: ern NCDENR Customer Service Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 1 800 623-7748 F WATF \O�O 9oG Michael F. Easley Governor P William G. Ross Jr., Secretary > North Carolina Department of Environment and Natural Resources O Y Alan Klimek, P.E. Acting Director Division of Water Quality This application has been assigned to Sergei Chernikov (919/733-5083) Ext. 594 of our NPDES Unit for review. You will be advised of any comments, recommendations, questions or other information necessary for the review of the application. - I am, by copy of this letter, requesting that our Regional Office Supervisor prepare a staff report and recommendations regarding this discharge. If you have any questions regarding this application, please contact the review person listed above. cc: Fayetteville Regional Office ©gin NCDENR Customer Service 1 800 623-7748 Sincerely //, �� 7� Sergei Chemikov, Ph.D. Environmental Engineer H NPDES-West Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 T ' •, Division of Water nuolit), / Water Quality Section NCDENRNational Pollutant Discharge Elimination System a. P. RE NCGO50000 NOTICE OF INTENT FOR AGENCY USE ONLY Year Mnmh Dnv c"'iificale of Cmei�e/ _ fheak Amount 1'ennii Assi neJ w OKO✓qOl-t, (1 National Pollutant Discharge Elimination System application for coverage under General Permit NCG050000: STORMWATER DISCHARGES associated with activities classified as: SIC 23 Apparel and Other Finished Products Made from Fabrics -in(] Similar Maier I P= - fats SIC 265 Paperboard Containers and Boxes - SIC 267 Converted Paper and Paperboard Products SIC 27 Printing, Publishing and Allied Industries SIC 30 Rubber and Miscellaneous Products (except as specified below) NOV 2 1 2005 SIC 31 Leather and Leather Products (except as specified below) SIC 39 Miscellaneous Manufacturing Industries ' The following activities are specifically excluded from coverage under this General Permit: ------ SIC 301 Tires and Inner Tubes SIC 311 Leather Tanning and Finishing O `q ' Standard Industrial Classification Car cat ¢i (Please print or type) > v 1) Mailing address of owner/operator: tinn !! L Name _Fex Straw Manufacturing Inc. Street Address _191 Magna Blvd. City _Lumberton State _NC_ ZIP Code _28360 Telephone No. _(910) 671-4141 Fax: _(910) 671-1138 2) Location of facility producing discharge: Facility Name Facility Contact Sheet Address City County Telephone No. Address to which all permit correspondence will be mailed _Fex Straw Manufacturing Inc. _Ms. Brenda Tompkins _191 Magna Blvd. Lumberton Stale NC ZIP Code 28360 _(910) 671-4141 3) Physical Location Information: Fax: _(910) 671-1138 Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). _Exit 17 off 1-95, NW on NC-72 for -3.5 miles, Left on Lowe Road for -02 miles, Right on Magna Blvd._ (A copy of a county map or Uses quad sheet with facility clearly located on the map is iequiicd lu be submitted will his applicalion) 4) This NPDES Permit Application applies to which of the following : O New or Proposed Facility Date operation is to begin Page 1 of 3 SWU-220-10170E NCG050000 N.O.I. V�p 9 Existing 5) Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: 3 9 9 9 6) Provide a brief narrative description of the types of industrial activities and products manufactured at this facility: _Manufacturing of horse bedding from straw 7) Discharge points / Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater from the property? _One What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater discharges end up in? Jacks Branch Creek If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). _NA 8) Does this facility have any other NPDES permits? CI No RI Yes If yes, list the permit numbers for all current NPDES permits for this facility: _Applied for NCG500000 9) Does this facility have any Non -Discharge permits (ex: recycle permits)? ® No ❑ Yes If yes, listthe permit numbers for all current Non -Discharge permits for this facility: 10) Does this facility employ any best management practices for stormwater control? ❑ No ® Yes If yes, please briefly describe: _Covered storage, Secondary containment of ASTs, Inspections 11) Does this facility have a stormwater Pollution Prevention Plan? ❑ No 19 Yes If yes, when was it implemented? _July 2005 12) Are vehicle maintenance activities occurring at this facility? ® No ❑ Yes 13) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? ® No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? 19 No ❑ Yes Page 2 of 3 SWU-220-101701 NCG050000 N.O.I. c) Is this facility a Large Quantity Generator( 1000 kg. or more of hazardous waste generated per month) of hazardous waste? ® No ❑ Yes d) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor:_ Vendor address: 14) Certification: North Carolina General Statute 143-215.6 b (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission iniplemen ing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $10,000, or by imprisonment not to exceed six months, or by both. ( I S U.S.C. Section 1001 provides a punishment by a fine of not more than $10.000 or implisonntent not more than 5 years, or both, for a similar offense.) I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit, I certify that I am familiar with the information contained in this application and That to the best of my knowledge and belief such information is true, corn te, and accurate. Printed Nor 1e of Person Signing: f-Qn -cA0. 1 o rnp K �S Title: C)f�-'4�& 1Aci x ceii- ofApplicant)'� (Date Signed) Notice of Intent must be accompanied by a check or money order for $80.00 made payable to: NCDENR Final Checklist This application will be returned as incomplete unless all of the following items have been included 29 Check for $80 made payable to NCDENR P� This completed application and all supporting documents ® Copy of county map or USGS quad sheet with location of facility clearly marked on map Mail the entire package to: Slormwater and General Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Page 3 of 3 S W U-220-101701 74 :7 $Pita NORTHWEST LUMBERTON QUADRANGLE LUMBERTON, NORTH CAROLINA, 1993 T y1 17ICINITY AfAP urmtser DRAWnc Eml"�Fml DAM 0/11104 � sc� N.t l J-arrJ—ms I— Ars -J_ PREPMEO FOR: FZX STRAW JUNUFACTUBING e 19/ Afg� Blvd L.bt.n, NC 28360 PREPMM aamFIGURE 1 ^ fit. 1. -•_ 1 I .,. r A 1 V 1 1 �� ��� nA1 r t_. S� I I� ,�• �. sr u �� _ VvX x• ♦ b ` �,.}��, �r \\� ��� \ � ',i � � I�\\� g ,yI ,',� rya% / �\ ♦X .♦ `✓ (/ 1'ai F Imo.. (�7 `2 �.._/u"! / \ rt SjY'*•4 `i .:) � / \ •) - rt � /—�.'__-./V> .ti �.., l (�(-.r---y. ¢ OF/1 x � �� r' ^— 1 � Isa, lam, 4 • ti r `��� �`fJ 7 r �� / vr1.y v v, ' In Q• 2' hi �' ^ iUl r '"t 44, :♦ .. 1 S •� •1 fig y i 1�� Q151. ` �'J• �V'a�FF#��1��'�";�`�� t���< ����' � �f� a�'� A ��I �fl ���n� r s S� 9�\ �'"d•%`.f*'*x^Ne,: 1n}k tr ry 5 b 1 r• 5 r . i r +T�1 +k�u'+ M9 x y %p 1r n, fir` r'",#ag'^+xl �'ue ypyy(ryl 1 %-�\ "�'+r �S✓� k t �+x� k�'i�yq 'S 'yT a. ♦ 54hx 1 � J f/ � � � ,.t�'y / arY ' ..� v b ailf �sx'w'�7 �y`♦ �' ,�i._ x. L�"af' �.� It x n :.� I.F 1 ti ,r J. r�,;3- 'L?` a ♦"� // vy3,,� aa" �� � � �� �f i x ,�`" r Al �� ✓r ,ry �� _� 14�1 � 1♦ 77 n._ �\ .- ./.��. �.. �T ,._. x _', A\-.',_ 1 .. /7•�S"� ,1. .` d.,-.�. >n..'Td, ?+_�p:. :�_.� � `ei Division of Water- Quality / iWater Quality Section NCDENR Nation ktTojlujarMVj�sch!arge Elimination System Nanx Cwou,u Cvugn¢x+w ' i Exvigoxx[rrt •vo Nawu Ne�wgep NCG500000 W USE ONLYeivedth Doai Covers eAmountD.oO 6�4� ned to NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under General Permit NCG500000: Non -contact cooling water, cooling tower and boiler blowdown, condensate, exempt stormwater, cooling waters associated with hydroelectric operations and similar wastewaters (Please print or type) 1) Owner/operator: Company Name: _Fex Straw Manufacturing Inc. Contact Person: _Ms. Brenda Tompkins Street Address: _191 Magna Blvd. City: _Lumberton State: —NC_ ZIP Code: 28360 Telephone No.: _(910) 671-4141 Fax: _(910) 671-1138 2) Location of facility producing discharge: Facility Name: Contact Person: Street Address: City: County: Telephone No.: State: ZIP Code: Fax: 3) Permit Contact (complete this section if permit contact is different from facility contact) : Contact Person: Street Address: City: County: Telephone No.: 4) Physical location information: State: ZIP Code: Fax: A copy of an USGS quad map or county map with the facility clearly located on the map IS REQUIRED to be submitted with this application. Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection): _Exit 17 off 1-95, _NW on NC-72 for —3.5 miles, Left on Lowe Road for —0.2 miles, Right on Magna Blvd. 5) This NPDES permit application applies to which of the following: Newor.Proposed - ❑ Modification Please describe the modification: ❑ Renewal Please specify existing permit number and original issue date: swu-212-080102 Page 1 of 4 NCG500000 N.O.I. 6) Does this facility have any other NPDES permits, including stormwater general permits? ❑ No ® Yes If yes, list the permit numbers for this facility: _Applied for NCGO50000 7) What is the nature of the business applying for this permit? _Manufacturing horse bedding from straw 8) Description of Discharge: a) Total number of discharge points that convey wastewater from the property, including ditches, pipes, channels, etc.: One b) What type of wastewater is discharged and from which discharge points? ❑ Non -contact cooling water Discharge point(s) # : ❑ Boiler Blowdown Discharge point(s) # : ❑ Cooling Tower Blowdown Discharge point(s) # : ❑ Condensate Discharge point(s) #: ® Other Discharge point(s) #: _001 (Please describe "Other") : _Steam Condensate c) Approximate volume of discharge for each discharge point (in GPD): #1: _80 gal of condensate_ #2: #3: #4 9) Please check the type of chemical added to the wastewater for treatment for each separate discharge point (if applicable, use separate sheet) ❑ Biocides Name: Manuf.: Cl Corrosion inhibitors Name: Manuf.: ❑ Chlorine Name: Manuf.: ❑ Algaecide Name: Manuf.: ❑ Other Name: Manuf.: If any box above, other than none, was checked, a completed Biocide 101 Form and manufacturers information, including MS/DS sheets on the additive IS REQUIRED to be submitted with the application for the Division's review. 10) Discharge Frequency: a) The discharge is: ❑ Continuous ® Intermittent i) If the discharge is intermittent, describe when the discharge will occur _During operating hours (8016 hours per day) ❑ Seasonal ii) If seasonal check the month(s) the discharge occurs: ❑ Jan. ❑ Feb. ❑ Mar. ❑ Apr. ❑ May ❑ Jun. ❑ Jul. ❑ Aug. ❑ Sept. ❑ Oct. ❑ Nov. ❑ Dec. b) How many days per week is there a discharge? _Five 11) Receiving waters: a) What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility wastewater discharges end up in? If the site wastewater discharges to a separate storm sewer system (4S), name the operator of the 4S (e.g. City of Raleigh) : _Jacks Branch Creek b) Stream Classification (WS-IV, NSW, etc.) : Jacks Branch Creek feeds into Lumber River which is CSw Page 2 of 4 S W U-212-080102 NCG500000 N.O.I. c) Is the discharge directly to the receiving water? ❑ Yes (9 No If no, a site map with the pathway to the potential receiving waters clearly marked IS REQUIRED to be submitted with the application. This includes tracing the pathway of the storm sewer to the discharge point, if the storm sewer is the only viable means of discharge. 12) Is there any type of treatment being provided to the wastewater before discharge (i.e., retention ponds, settling ponds, etc.)? ❑ Yes 2 No If yes, please include design specifics (i.e., design volume, retention time, surface area, etc.) with submittal package. Existing treatment facilities should be described in detail. Design criteria and operational data (including calculations) should be provided to ensure that the facility could comply with the requirements of the General Permit. The treatment shall be sufficient to meet the limits set by the general permits. Note: Construction of any wastewater treatment facilities requires submission of three (3) sets of plans and specifications along with the application. Design of treatment facilities must comply with the requirements of 15A NCAC 2H .0138. If construction applies to this discharge, include the three sets of plans and specifications with this application. 13) Pollutants: Please list any known pollutants that are present in the discharge, per each separate discharge point (if applicable, use separate sheet) : _None 14) Alternatives to Direct Discharge: Address the feasibility of implementing each of the following non -discharge alternatives : a) Connection to a Regional Sewer Collection System b) Subsurface disposal (including nitrification field, infiltration gallery, injection wells, etc.) c) Spray irrigation The alternatives to discharge analysis should include boring logs and/or other information indicating that a subsurface system is neither feasible nor practical as well as written confirmation indicating that connection to a POTW is not an option. It should also include a present value of costs analysis as outlined in the Division's "Guidance For the Evaluation of Wastewater Disposal Alternatives". 15) Additional Application Requirements: For new or proposed discharges, the following information MUST BE INCLUDED in triplicate with this application or it will be returned as incomplete. a) 7.5 minute series USGS topographic (quad) map (or a photocopied portion thereof) with discharge location clearly indicated. b) Site map. If the discharge is not directly to a stream, the pathway to the receiving stream must be clearly indicated. This includes tracing the pathway of a storm sewer to its discharge point. c) If this application is being submitted by a consulting engineer (or engineering firm), include documentation from the applicant showing that the engineer (Or firm) submitting the application has been designated an authorized Representative of the applicant. d) Final plans for the treatment system (if applicable). The plans must be signed and sealed by a North Carolina registered Professional Engineer and stamped -"Final Design -Not released for construction". Page 3 of 4 SWU-212-080102 NCG500000 N.O.I. e) Final specifications for all major treatment components (if applicable). The specifications must be signed and sealed by a North Carolina registered Professional Engineer and shall include a narrative description of the treatment system to be constructed. certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: of Applicant) North Carolina General Statute 143-215.6 b (1) provides that: p1C � ns 1 I - ►IJ-os ^(Date Signed) Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $10,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment not more than 5 years, or both, for a similar offense.) Notice of Intent must be accompanied by a check or money order for $80.00 made payable to: NCDENR Mail three (3) copies of the entire package to: Stormwater and General Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Final Checklist This application will be returned as incomplete unless all of the following items have been included: ® Check for $80 made payable to NCDENR ® 3 copies of county map or USGS quad sheet with location of facility clearly marked on map N 3 copies of this completed application and all supporting documents NA ❑ 3 sets of plans and specifications signed and sealed by a North Carolina P.E. ® Alternatives analysis including present value of costs for all alternatives Note The submission of this document does not guarantee the issuance of an NPDES permit Page 4 of 4 SW U-212-080102 Attachment 1 Alternatives to Direct Discharge Surface discharge followed by overland flow to a receiving water has been determined to be the best alternative for the discharge of this steam condensate. There is no Regional Sewer Collection System available in the area so that option is not available. Due to the small volume of the discharge (80 GPD) the installation of a subsurface disposal system with the associated permitting requirements is not practical or cost effective. There are no crops on the site that require irrigation and the elevated temperature of the water when discharged at the site is not appropriate for irrigation. The overland path that the discharge must follow before entering a water body is long enough to allow the majority of the water to infiltrate naturally and to cool to ambient temperature. Attachment 1 Alternatives to Direct Discharge Surface discharge followed by overland flow to a receiving water has been determined to be the best alternative for the discharge of this steam condensate. There is no Regional Sewer Collection System available in the area so that option is not available. Due to the small volume of the discharge (80 GPD) the installation of a subsurface disposal system with the associated permitting requirements is not practical or cost effective. There are no crops on the site that require irrigation and the elevated temperature of the water when discharged at the site is not appropriate for irrigation. The overland path that the discharge must follow before entering a water body is long enough to allow the majority of the water to infiltrate naturally and to cool to ambient temperature. Attachment 1 Alternatives to Direct Discharge Surface discharge followed by overland flow to a receiving water has been determined to be the best alternative for the discharge of this steam condensate. There is no Regional Sewer Collection System available in the area so that option is not available. Due to the small volume of the discharge (80 GPD) the installation of a subsurface disposal system with the associated permitting requirements is not practical or cost effective. There are no crops on the site that require irrigation and the elevated temperature of the water when discharged at the site is not appropriate for irrigation. The overland path that the discharge must follow before entering a water body is long enough to allow the majority of the water to infiltrate naturally and to cool to ambient temperature. YoJ No P. i �f4 I F.- V ., r