Loading...
HomeMy WebLinkAboutSWA000065_(1)Gardner Mini Storage-Cover_2/21/2020VICINITY MAP No Scale SHEET INDEX-- 1 COVER SHEET 2. SITE PLAN 3. EROSION CON7190L PLAN 4. CONSTRUCTION DETAILS 5. DETAIL SHEET 6. NCG01 SHEET 1 7. NCG01 SHEET 2 PUBLIC UTILITIES NOTES (HRW) 1. 3/4" WATER METER IS REQUESTED TO BE INSTALLED BY COUNTY HRW FORCES 2. LOCATION OF WATER METER AND AND BACK FLOW PREVENTER ARE SHOWN ON SITE PLAN SHEETS 1 AND 2 3. PUBLIC WATER SHALL BE USED. PLANS SHALL BE REVIEWED AND APPROVED BY HRW BEFORE CONSTRUCTION BEGINS 4. THE EXISTING 16-INCH WATER MAIN ALONG HWY 210 IS SHOWN ON THE SITE SHEETS 1 AND 2 5. ATTACHED IS NCDOT DRIVEWAY PERMIT. THERE ARE NOT WIDENING IMPROVEMENT ON NC 210 IN THE SITE AREA AS PART OF THIS PROJECT 6. THERE NO OFFICE PLANNED FOR THE SITE, THEREFORE NO SEWER IS NEEDED OR REQUESTED. NO NEED FOR FUTURE SEPTIC IS ANTICIPATED 7. SYSTEM DEVELOPMENT FEES SHALL BE PAID PER HRW&S USE ORDINANCE. 8. UTILITY IMPROVEMENTS MUST BE DESIGNED AND INSTALLED IN ACCORDANCE WITH LATEST HARNETT COUNTY AND STATE REQUIREMENTS 9. THE ENGINEER OF RECORD SHALL SUBMIT A MATERIAL LIST TO HRW WITH ENGINEER APPROVAL THAT THE MATERIALS MEET HRW SPECIFICATIONS 10. THE ENGINEER OF RECORD SHALL SUBMIT ALL ENGINEERING FINAL DOCUMENTS PRIOR TO HRW APPROVAL OF WATER EXTENSIONS. 11. ALL HARNETT COUNTY EXISTING AND PROPOSED EASEMENTS SHALL CONVEYED AND RECORDED AND NOTED ON THE PROPOSED PLAT PRIOR TO ACTIVATION OF THE UTILITY SYSTEM 12. PROFESSIONAL ENGINEER (PE) SHALL PROVIDE HRW WITH A SET OF AS -BUILT RECORD DRAWINGS (IN MYLAR, BOND AND DIGITAL FORMATS), THE P.E. THAT THE TAPS AND ASSOCIATED UTILITIES WERE INSTALLED IN ACCORDANCE WITH APPROVED PLANS MARKED AS "RELEASED FOR CONSTRUCTION" 13. THE DEVELOPER SHALL PROVIDE HRW A COST STATEMENT INDICATING THE COST TO INSTALL THE WATER LINES (MATERIALS AND LABOR) THAT WILL SERVE THIS SITE. 14. THE UTILITY CONTRACTOR SHALL PROVIDE HRW WITH A ONE (1) YEAR WARRANTY ON THE WATER UTILITIES TO COVER ANY AND ALL REPAIRS DUE TO POOR WORKMANSHIP, DEFECTIVE MATERIALS OR ANYTHING THAT DOES NOT MEET HRW STANDARDS AND SPECIFICATIONS AT THE TIME THE WORK WAS PERFORMED TO INSTALL THE WATER UTILITIES. 15. NO SERVICES SHALL BE ACTIVATED UNTIL ALL UTILITIES ARE APPROVED IN ACCORDANCE WITH STATE REGULATION AND THE LATEST HRW RULES AND REGULATIONS One 3/4" water meter is proposed for the site. with estimated water usage of 400 g/d. Water usage is basically for occasional washing_ and/or watering NOTE: THERE IS NO WETLAND ON THE PROPERTY AS DETERMINED BY CIVIL AND STRUCTURAL ENGINEERING SERVICES, PLLC i I I I � I 1 I I I . 1. I ►► I ►• 1 F H I ►. I u W/6" GV undergro nc� � ►; cable '+ > I 16" AC Water Main I 1' I 111 ►� 1 1 ' r 11 I , U 1' I , 1� I'� I 1+ � I ►11 1� 1 I CP ►. 11 I �+ 3/4" WATER METER I '+ SEE STANDARD ►I DETAIL 1� I' BACKFLOW I I ►; PREVENTER ICIP 1+ (RPZ) 1 /4" Febco I II �. or type ►f by HCPU 1 u � I1; I 11 I ►1 I ►1 I + 1� Note to contractor: Before starting digging or grading, call to located all underground utilities NOTES " OTES: 1. FOR GRADING AND WATER, SEE SHEET 2 AND DETAIL SHEETS 2. FOR EROSION AND SEDIMENT CONTROL, SEE SHEET 3 OPEN SPACE S7-01? E METAL BU/LD/NG STORAGE METAL BU/LD/NG M/N/ STORAGE METAL BU/LD/NG OPEN Y SPACE I I I I Y I OUTDOOR STORAGE AREA j DETENTION II j POND LEGEND I X X SILT FENCE I I0 0 CHAIN LINK FENCE I �� E-----F--- GRASS SWALE I I TYPE D' BUFFER TOP OF DAM - - RIGHT OF WAY � STORM PIPE BUFFERS AND LANDSCAPING A) BUFFERS FOR THIS SITE SHALL MEET REQUIREMENT OF SECTION 9.0 OF HARNETT COUNTY UDO. B) ALL BUFFER TYPES SHALL INCLUDE THE FOLLOWING IN ADDITION TO THE SPECIFIC BUFFERING REQUIREMENT • A STAGGERED ROW OF LARGE MATURING TREES, SPACED NOT MORE THAN 30 FEET APPART; AND • LOW -GROWING EVERGREEN SHRUBS, EVERGREEN GROUND COVER, OR MULCH COVERING THE BALANCE OF THE BUFFER AREA TYPE A BUFFER 1. MINIMUM WIDTH OF 15' (APPLIES TO SIDES AND REAR PROPERTY LINES) 2. OPTION 1: A ROW OF EVERGREEN SHRUBS PLACED NOT MORE THAN FOUR(4) TO SIX (6) FEET APART WHICH WILL GROW TO FORM A CONTINUOUS HEDGE OF AT LEAST SIX (6) FEET IN HEIGHT WITHIN TWO (2) YEARS OF PLANTING; OR 3. DEVELOPER CAN OPT FOR 2 OR OPTION 3. REFER TO SECTION 9.1.8 (B) TYPE D BUFFER 1. MINIMUM WIDTH OF 15 FEET (APPLIES TO PROPERTY LINES ADJACENT TO PUBLIC RIGHT-OF-WAY OR AS OTHERWISE NOTED WITHIN THIS ORDINANCE 2. OPTION 1 A ROW OF EVERGREEN SHRUBS, 10 SHRUBS FOR EVERY REQUIRED LARGE MATURING TREE, PLACED NOT MORE THAN FOUR (4) FEET APART WHICH WILL GROW TO FORM A CONTINUOUS HEDGE OF AT LEAST SIX (6) FEET IN HEIGHT WITHIN TWO (2) YEARS OF PLANTING; OR 3. DEVELOPER CAN OPT FOR 3 (OPTION 2) . REFER TO SECTION 9.1.8 (E) OWNER, ENGNEER AND SURVEYOR OWNER TRAVIS SCOT WESTER 3631 NC 210 N LILLINGTON, NC 27546 PLANNING NOTES 1. LAND USE: MEDIUM DENSITY RESIDENTIAL 2. HOURS OF OPERATION: GATE WILL REMAIN CLOSED AND ACCESS VIA PRIVATE CODE 3. CONDITIONAL USE PERMIT # BOA1906-0003 APPROVAL DATE 7/18/19 4. WATERSHED PERMIT# SNIA1908-0003 APPROVAL DATE 9/9/19 5. REFER TO LANDSCAPE BUFFER NOTES ON SHEET 2 OF PLANS 6. THERE SHALL BE NO BUSINESS ACTIVITY SALE, SERVICE, OR REPAIR ACTIVITIES, OTHER THAN RENTAL OF THE STORAGE UNITS CONDUCTED WITHIN THE STORAGE FACILITIES 7. NC 210 IS ON THE HARNETT COUNTY COMPREHENSIVE TRANSPORTATION PLAN 8. THIS DEVELOPMENT IS WITHIN ONE MILE OF VOLUNTARY AGRICULTURAL DISTRICT 9. LIGHTING SHALL BE LOCATED IN SUCH A MANNER AS TO PREVENT DIRECT GLARE AND LIGHTING ON ADJACENT PROPERTY OR INTO THE PUBLIC RIGHT(S)-OF-WAY. ALL FLOOD LIGHTS SHALL BE INSTALLED SUCH THAT THE FIXTURES SHALL BE AIMED DOWN AT LEAST 45 DEGREES FROM VERTICAL 10. NO OFFICE SHALL BE INSTALLED ON SITE, THEREFORE NO NEED FOR ON SITE SEWER. IF A SEPTIC SYSTEM SHALL BE USED IN THE FUTURE, A SOIL REPORT IS NECESSARY FOR APPROVAL 11. SOLID WASTE: ROLLING TRASH CAN SHALL BE KEPT ON SITE TO BE ROLLED BY OWNER TO THE STREET SIDE ON PICKUP DAY THE SITE SHALL COMPLY TO TO STORM WATER STATEMENT ARTICLE X, SECTION 2.5 OF THE HARNETT COUNTY UDO FEMA FLOOD HAZARD STATEMENT: Lot shown on this plat is not located within the FEMA Flood Hazard "Zone AE" as shown on FEMA map No. 3720066000J Effective Date: 10/03/2006 TEL: (910) 890-3403 Property is located in Watershed DEVELOPER: JOE GARDNER District IV, Protected 1116 TYSINGER RD LILLINGTON, NC 27546 TEL: (910)891-9600 ENGINEER: CIVIL AND STRUCTURAL ENGINEERING SERVICES, PLLC (BUSINESS LICENSE # P-0537) SAMIR W. BAHHO, PE (LICENSE # 16941) 4612 KAPLAN DRIVE, RALEIGH, NC 27606 TEL: (919) 851-1642 FAX: (919) 854-1960 CELL: (919) 621-0628 BACASESPLLC@GMAIL. COM SURVEYOR STANCIL & ASSOCIATES , P.A. C-0831 AS THE OWNER OF RECORD, I HEREBY, CONSENT TO THE PROPOSED DEVELOPMENT SHOWN ON THIS SITE PLAN AND ALL REGULATIONS AND REQUIREMENTS OF THE HARNETT COUNTY ORDINANCES. DATE OWNER SIGNATURE 98 Depot Street, P.O. Box 730 , Angier, North Carolina 27501 Tel- (919 639-2133 Fax- (919) 639-2602 Email- stancilsurvey@gmail.com Existing Impervious Area: 0.00 Proposed Impervious Area: 108900 SF. Or 2.5 Acres Proposed Impervious Area: 50.0% Plan revised to address RDB comments (11/12/2019) August 06, 2019 :4. rA1• i f w 16'9�1 o+�o, •« a a w w o WC\��LO w qa�a W w C\2 Pq � x E, rr�� �1 Cn o� U O U J J cfl LO LO ZN C) Z E-, W � W Z o Q N C) x o 0Z O M C� G a r~ U w w a Z m V J z N E O e V l O ca a W N =D W �D � z 0 rz U 40 � s N w o ij Q a ~ N N owl z" DATE: -10-2019 SCALE: 1 "--40' DESIGNED: SW8 CHECKED: SWS DRAWN: SWJ APPROVED: SW8 SHEET: SI TE PLAN 1 OF 4 CAD FILE:GMS PROJECT NO: 2019.0.3