Loading...
HomeMy WebLinkAboutSW6191203_SW Report_20200131STORMATER IMPACT ANALYSIS for GLEN MEADOW SUBDIVISION PHASE 2 Submittal to: TOWN OF ANGIER, NORTH CAROLINA Submittal date: 9/20/2019 1/30/2020 Owner / Developer: SMITH-STAFFORD, LLC. 246 Valleyfield Lane Southern Pines, NC 28387 Contact: Bob Stafford Phone: (910) 692-9801 Prepared by: J THOMAS ENGINEERING, INC. CIVIL ENGINEERING & PLANNING 143 Charlotte Avenue, Suite 104 Sanford, North Carolina 27330 919-777-6010 phone www.jthomasengineering.com RE Project #: 19-017 DDS Project# 2019-13 a Zola TABLE OF CONTENTS SECTION I. EXISTING CONDITIONS PAGE A. PROPERTY....................................................................................................I B. WATERSHED.................................................................................................2 C. JURISDICTIONAL WATERS............................................................................2 D. FEMA FLOOPLAIN.......................................................................................2 E. SOILS............................................................................................................2 II. AGENCY STORMWATER REQUIREMENTS A. TOWN OF ANGIER.......................................................................................2 B. NCDEQ........................................................................................................2 III. PROPOSED IMPROVEMENTS A. PROJECT DESCRIPTION...............................................................................3 B. LAND DISTURBANCE AND EROSION CONTROL.........................................3 C. IMPERVIOUS SURFACE................................................................................3 D. DRAINAGE AND STORMWATER MANAGEMENT.......................................4 APPENDICES A. Calculations for: Minor System Culvert BMP Swale Erosion Control B. Drainage Area Maps: Post Drainage Area Erosion Control Drainage Area C. Wetland Impact Map D. Soil Survey Map E. FEMA FIRM Map F. USGS MAP EXISTING CONDITIONS A. PROPERTY The proposed project is on an existing 10.1 AC tract (PIN 067-95-6622) in Harnett County and within the Town of Angier ETJ. This 10.1 AC property is zoned R-10 and is located adjacent to the previously constructed Glen Meadows Phase 1 project. The property is currently undeveloped and wooded (except for a sewer outfall line that was installed for the Phase 1 of Glen Meadow) with no impervious surfaces. There has been no change in use after July 25, 2002. The following is a summary of the adjacent properties: To the north, an existing single family subdivision (zoning R-10) To the south, an existing single family subdivision (zoning R-10) To the west, an existing single family subdivision (zoning R-10) To the east, existing farm land (zoning R-30) See Figure 1 below for an aerial view of the property for the proposed Glen Meadows Phase 2 project (Site). Figure 1: Aerial view of pre -developed site Stormwater Impact Analysis - Glen Meadow Subdivision Phase 2 Page 1 1 5 B. WATERSHED The site is located in the Black River Watershed and Cape Fear River Basin. The NCDEQ Stream Index for Black River is 18-68-12-1. The NCDEQ Classification for Black River is C, Sw. C. JURISDICTIONAL WATERS There are two (2) jurisdictional streams located on the site. These streams are USGS `blue lines' (see Appendix F). There is also approximately 4.7 AC of jurisdictional wetlands located on the site (see Appendix C for location of jurisdictional streams and wetlands in relation to the project). D. FEMA FLOODPLAIN There are no FEMA mapped floodplains located on the site per FIRM Panel 3720067400K, effective date Oct. 3, 2006 and 3720068400K, effective date May 2, 2006. See Appendix E for FEMA FIRM maps. E. SOILS Refer to Appendix D for the NRCS map showing anticipated on -site soils. II. AGENCY STORMWATER REQUIREMENTS A. TOWN OF ANGIER Section 9.4 `Stormwater Management' of the Angier UDO details the requirements for managing stormwater from new construction sites. B. NCDEQ Stormwater Impact Analysis - Glen Meadow Subdivision Phase 2 Page 2 1 5 Harnett County is a `tipped' county and new projects located within the county must meet NCDEQ Post Construction Stormwater Phase 2 regulations. Site requirements for stormwater control are different if the proposed development is `high density' (greater than 24% impervious) or `low density' (less than 24% impervious). III. PROPOSED IMPROVEMENTS A. PROJECT DESCRIPTION The proposed project, which will be developed in a single phase, will create fifteen (15) single family lots (min 10,000 sf). The proposed project will extend Glen Meadow Drive approximately 2,000 LF terminating in a cul-de- sac. The design follows the Preliminary Plat that was recently approved by the Town of Angier. As part of this project, public water and sewer utilities will be extended to serve the new lots. B. LAND DISTURBANCE AND EROSION CONTROL The proposed disturbed area for the proposed project is 5.41 AC +/-. A NCDEQ Land Disturbance (Erosion Control) Permit will be obtained prior to beginning work. Within this limit of disturbance, 0.49 AC of jurisdictional wetlands and 81 LF of jurisdictional streams will be impacted. See Appendix C for the `Wetland Impact Map'. A USACE 404 Permit and NCDEQ 401 Certification for the proposed impacts will be obtained by the owner prior to beginning work. C. IMPERVIOUS SURFACE The proposed amount of impervious surfaces for this project total 2.43 AC. This includes pavement and curb & gutters in the public R/W and driveways and rooftops on each lot. This proposed amount of impervious surfaces results in a percent impervious (or built -upon) of 23.9% of the total property area. The proposed amount of impervious surfaces is based on a maximum amount of 4,646 SF of impervious area on each lot. Stormwater Impact Analysis - Glen Meadow Subdivision Phase 2 Page 3 1 5 D. DRAINAGE AND STORMWATER MANAGEMENT i. Roadway Drainage - Minor System The proposed roadway will have curb and gutter. Catch basins in the gutter line will provide the roadway drainage. Catch basins were spaced based on gutter spread not exceeding one-half lane width during a 4 in/hr storm (NCDOT guidelines). The minor pipe system is sized based on 10-year storm flow not exceeding the hydraulic capacity of each pipe segment (as open channel flow, that is, non -pressure flow). ii. Roadway Drainage - Culverts Three (3) culverts will be installed along the roadway to convey drainage from one side of the road to the other. These culverts were sized based on conveying the 25-year storm with headwater not exceeding 1.2 Hw/D (NCDOT guidelines). Culvert # 1 is a double barrell culvert consisting of 1 A and 1 B. Culvert# 1 A (24" diameter) located within a jurisdictional stream will be partially buried into the stream channel bottom to help off -set environmental impacts. Because it is partially buried, the hydraulics were analyzed assuming a 18" diameter (NCDOT guidelines). Culvert #113 (36" diameter) has been analyzed to convey the additional upland drainage to the south side of the proposed roadway. iii. BMP Swales As stated in Section III. C. above, proposed impervious is less than 24% and, therefore is classified as `Low Density' per NCDEQ regulations. Per NCDEQ guidance, BMP swales are proposed to receive runoff collected by the catch basins in the road system to help treat the runoff before being discharged to the jurisdictional waters. These swales have a longitudinal slope of 0% to encourage infiltration and a level berm to help prevent concentrated flow from entering the jurisdictional wetlands. There are four (4) proposed BMP swales, each with a minimum length of 100 LF. Stormwater Impact Analysis - Glen Meadow Subdivision Phase 2 Page 4 1 5 iv. Methodology and computations Refer to Appendix C for storm drainage and stormwater management computations. Hydrologic computations were based mainly on the Rational Method except for Culvert #lA & #1 B that was analyzed using the NCDOT Method (Urban Drainage).. Rainfall intensity was determined based on data of the closest rainfall gauge listed on the NOAA website. Drainage areas were delineated based on a combination of field and LIDAR topography. Stormwater Impact Analysis - Glen Meadow Subdivision Phase 2 Page 5 1 5 Upstream Node Downstream Node Upstream Inlet C Upstream Inlet Area (acres) Upstream Intensity' (in/h) Pipe Diameter (in) Material Pipe Length (ft) Capacity (Full Flow) (ft3/s) Total Pipe Flow (ft'/s) Total System Flow (ft3/s) Slope (ft/ft) Invert (Upstream) (ft) Invert (Downstream) (ft) Inlet* Elevation (Rim) (ft) (4) Elevation (Invert) (ft) Inlet Type Bypass Target Gutter I=4 in/hr (ft3/s) (3) Gutter Flow (Total Intercepted) (ft3/s) Gutter Flow (Total Bypassed) (ft3/s) CB 601 (2) FES 600 0.65 0.90 7.62 15 Class III RCP 12.00 4.50 4.46 4.46 0.0042 311.55 311.50 CB 601 (2) 313.52 (2) ANGIER STD: STRM_03.02 2.34 2.34 0.00 CB 501 (2) FES 501 0.65 0.90 7.62 15 Class III RCP 12.00 4.50 4.46 4.46 0.0083 310.60 310.50 CB 501 (2) 313.52 (2) ANGIER STD: STRM_03.02 2.34 2.34 0.00 CB 402 (2) CB 401 0.65 0.43 7.62 15 Class III RCP 26.00 7.50 2.13 2.13 0.0115 311.45 311.15 CB 402 (2) 314.95 311.45 ANGIER STD: STRM_03.02 CB 202 1.12 0.86 0.26 CB 401 (2) FES 400 0.65 0.28 7.62 15 Class III RCP 22.00 15.64 1.39 3.52 0.0091 310.70 310.50 CB 401 (2) 314.95 310.70 ANGIER STD: STRM_03.02 CB 201 0.73 0.61 0.12 FES 301 (1) FES 300 0.30 2.03 8.46 15 Class III RCP 62.00 7.96 5.15 5.15 0.0047 311.00 310.71 FES 301 (1) - - NCDOT FLARED END SECTION - - - CB 202 (2) CB 201 0.65 0.33 7.62 15 Class III RCP 26.00 7.50 1.63 1.63 0.0115 309.44 309.14 CB 202 (2) 312.44 309.44 ANGIER STD: STRM_03.02 0.86 1.12 0.00 CB 201 (2) FES 200 0.65 0.33 7.62 15 Class III RCP 22.00 12.45 1.63 327 0.0091 308.70 308.50 CB 201 (2) 312.44 308.70 ANGIER STD: STRM_03.02 0.86 0.98 0.00 HW 101A (1) HW 100A JCDOTMETHOIJCDOTMETHOIJCDOTMETHOI 36 Class III RCP 51.00 46.90 46.90 33.80 0.0157 308.90 308.10 HW 101A (1) - - NCDOT 838.02 - - HW 101B (1) HW 100B JCDOT METHOI JCDOT METHOI JCDOT METHOI 24 Class III RCP 51.00 20.60 20.60 61.20 0.0157 307.90 307.10 HW 101B (1) NCDOT 838.02 Notes 1 Cross Pipe Sizing is based on 25-yr Storm 2 Storm System Sizing based on 10-yr Storm 3 Gutter Spread Calculations based on Storm Intensity of 4 in/hr 4 CB (Catch Basin) Rim Elevation is Back of Curb 5 Gutter Spread Width is measured from Edge of Pavement NCDOT Method Chart C200.1 NC Hydrologic Contours I Example: Hydrologic Contour 5.0 Drainage Area 35 ac Small Area — Full Business Q10=39A.4=55 cfs O z O U_ 0 O J O 0 M 4 — — — 3 CORRECTION FACTOR FOR DEVELOPMENT APPENDIX C 200 800 60 50 CFS 20 cn — U 10 8 6 4 K 1 &I 0111 46 AC 50 40 'L6 W 30 U 20 Q a W w 10 w c� Q z 5 0 FREQUENCY FACTORS 1 Q2 = Q10 x 0.50 Q 5 Q 10 x 0.75 _= Q25 = Q10 x 1.35 Q25 = 50 CFS X 1.0 X 1.35 Q50 = x 1.85 Q25=67.5 CFS Q100 = Q10 x 2.15 Q 500 = Q10 x 3.10 C200.3 URBAN RUNOFF CHART (REVISED) Culvert Report Hydraflow Express Extension for AutoCADO Civil 3D0 2009 by Autodesk, Inc. Culvert #1A Invert Elev Dn (ft) = 308.10 Pipe Length (ft) = 51.00 Slope (%) = 1.57 Invert Elev Up (ft) = 308.90 Rise (in) = 36.0 Shape = Cir Span (in) = 36.0 No. Barrels = 1 n-Value = 0.012 Inlet Edge = Projecting Coeff. K,M,c,Y,k = 0.0045, 2, 0.0317, 0.69, 0.5 Embankment Top Elevation (ft) = 314.00 Top Width (ft) = 43.00 Crest Width (ft) = 400.00 Elev (ft) 315.00 314.00 313.00 312.00 311.00 310.00 309.00 308.00 307.00 0 Culvert 11A Tuesday, Nov 26 2019 Calculated using NCDOT Method Calculations Q m i n (cfs) = 48.70 Qmax (cfs) = 48.70 Tailwater Elev (ft) = Normal Highlighted Qtotal (cfs) Qpipe (cfs) Qovertop (cfs) Veloc Dn (ft/s) Veloc Up (ft/s) HGL Dn (ft) HGL Up (ft) Hw Elev (ft) Hw/D (ft) Flow Regime = 48.70 = 48.70 = 0.00 = 8.46 = 8.46 = 310.38 = 311.18 = 312.50 = 1.20 = Inlet Control 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Cir Culvert HGL Embank Hw Depth (ft) 6.10 5.10 4.10 3.10 2.10 1.10 0.10 -0.90 -1.90 75 Reach (ft) Culvert Report Hydraflow Express Extension for AutoCADO Civil 3D0 2009 by Autodesk, Inc. Culvert #1 B Invert Elev Dn (ft) = 307.10 Pipe Length (ft) = 51.00 Slope (%) = 1.57 Invert Elev Up (ft) = 307.90 Rise (in) = 18.0 Actual pipe size 24" per NCDOT Shape = Cir Guidelines Analyze at 18" Span (in) = 18.0 pipe is Buried in Stream No. Barrels = 1 n-Value = 0.012 Inlet Edge = Projecting Coeff. K,M,c,Y,k = 0.0045, 2, 0.0317, 0.69, 0.5 Embankment Top Elevation (ft) = 314.00 Top Width (ft) = 43.00 Crest Width (ft) = 400.00 Elev (ft) 315.00 314.00 313.00 312.00 311.00 310.00 309.00 300.00 307.00 306.00 Culvert#1B Tuesday, Nov 26 2019 Calculated using NCDOT Method Calculations Q m i n (cfs) = 18.80 Qmax (cfs) = 18.80 Tailwater Elev (ft) = Normal Highlighted Qtotal (cfs) Qpipe (cfs) Qovertop (cfs) Veloc Dn (ft/s) Veloc Up (ft/s) HGL Dn (ft) HGL Up (ft) Hw Elev (ft) Hw/D (ft) Flow Regime = 18.80 = 18.80 = 0.00 = 10.64 = 10.64 = 308.60 = 309.99 = 312.51 = 3.07 = Inlet Control 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Cir Culvert HGL Embank Hw Depth (ft) ,.10 6.10 5.10 4.10 3.10 2.10 1.10 0.10 -0.90 -1.90 75 Reach (ft) Culvert Report Hydraflow Express Extension for AutoCADO Civil 3D0 2009 by Autodesk, Inc. CULVERT #2 Invert Elev Dn (ft) = 310.71 Pipe Length (ft) = 62.00 Slope (%) = 0.47 Invert Elev Up (ft) = 311.00 Rise (in) = 15.0 Shape = Cir Span (in) = 15.0 No. Barrels = 1 n-Value = 0.012 Inlet Edge = Projecting Coeff. K,M,c,Y k = 0.0045, 2, 0.0317, 0.69, 0.5 Embankment Top Elevation (ft) = 314.60 Top Width (ft) = 43.00 Crest Width (ft) = 200.00 Elev (ft) 315.00 314.00 313.00 312.00 311.00 310.00 309.00 0 CULVERT #1 B 5 10 15 20 25 30 35 40 45 50 55 - Cir Culvert HGL Embank Wednesday, Nov 20 2019 Calculations Qmin (cfs) = 5.15 Qmax (cfs) = 5.15 Tailwater Elev (ft) = Normal Highlighted Qtotal (cfs) = 5.15 Qpipe (cfs) = 5.15 Qovertop (cfs) = 0.00 Veloc Dn (ft/s) = 4.20 Veloc Up (ft/s) = 4.20 HGL Dn (ft) = 311.96 HGL Up (ft) = 312.25 Hw Elev (ft) = 312.44 Hw/D (ft) = 1.15 Flow Regime = Inlet Control 60 65 70 75 Hw Depth (ft) 4.00 3.00 2.00 1.00 0.00 -1.00 -2.00 80 85 Reach (ft) BMP Swale #■ 1 => DA # DSW#1 Calculate Flow - Rational Method 10-Vr Storm Q10 = CIA Q25 = 6.04 Channel Slope=1 0.00 Channel Depth= 1.00 Side Slopes= 6.00 Veloci = 0.54 Channel Linin¢ Shear Calculation C= 0.65 1= 7.62 in/hr A= 1.22 ac T=yds y= 62.4lbs dwete .1.24 ft T= 0 Ibs/ft2 s= 0 ft/ft Temporary=R,G DS75 Permanent= Bermudagrass Dissipation Swale # 2 => DA # F SW#2 Calculate Flow - Rational Method 10-Vr Storm Q10 = CIA Q25 = 5.84 Channel Slope= 0.00 Channel Depth= 1.00 Side Slopes= 6.00 Velocity - Channel Linin¢ Shear Calculation C= 0.65 1= 7.62 in/hr A= 1.18 ac T=yds y= 62.4lbs Overflow into Wetlands s/ft2 dwate .1.22 ft Overflow into Wetlands T= 0 lb s= 0 ft/ft Temporary= NAG DS75 Permanent= Bermudagrass BMP Swale #■ 3 => DA # DSW#3 Calculate Flow - Rational Method 10-Vr Storm Q10 = CIA Q25 = Channel Slope=1 Channel Depth] Side Slopes= Velocity= Channel Unin¢ Shear Calculation T=yds y= 62.4lbs dwate� 1.1 ft 0 Ibs/ft2 s= 0 ft/ft Temporary=R,G DS75 T= 4.16 0.00 1.00 6.00 0.47 C= 0.65 1= 7.62 in/hr A= 0.84 ac Permanent= Bermudagrass BMPSwale# 4 =>DA# F SW#4 Calculate Flow - Rational Method 10-Vr Storm Q10 = CIA Q25 = 5.80 Channel Slope= 0.00 Channel Depth= 1.00 Side Slopes= 6.00 Velocity - Channel Unin¢ Shear Calculation C= 0.65 1= 7.62 in/hr A= 1.17 ac T=yds y= 62.4lbs Overflow into Wetlands s/ft2 dwate .1.22 ft Overflow into Wetlands T= 0 lb s= 0 ft/ft Temporary= NAG DS75 Permanent= Bermudagrass FES600 Pipe Syste Flow FES 6 0 BMP Swale #1 Subcat Reach on Link BMP Swale #1 BMP #1 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 3 Reach FES600: Pipe System Flow FES 600 Hydrograph Avg. Plow bepth=1.06' ❑ Inflow 4.46 cfs I I I I I I I I I I I I I I I I ❑outflow -- -- -- -- -- -- -- -- W[aX Ve�':�.7-�-fry-- 4 3 2.31 cfs Caplacityr=4.46 cfs N U 3 -- 0 LL I I I I I I I I I I I I I I I 2 I I I I I I I I I I I I I I I I I I I I I I 1 12 13 14 Time (hours) BMP Swale #1 BMP #1 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 4 Summary for Pond 1 P: BMP Swale #1 Inflow = 4.46 cfs @ 1.05 hrs, Volume= 4.396 of Outflow = 3.35 cfs @ 1.25 hrs, Volume= 3.270 af, Atten= 25%, Lag= 12.1 min Primary = 3.35 cfs @ 1.25 hrs, Volume= 3.270 of Routing by Stor-Ind method, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs / 2 Peak Elev= 312.04' @ 1.25 hrs Surf.Area= 2,200 sf Storage= 1,231 cf Plug -Flow detention time= 182.8 min calculated for 3.270 of (74% of inflow) Center -of -Mass det. time= 5.9 min ( 756.7 - 750.8 ) Volume Invert Avail.Storage Storage Description #1 311.00' 1,231 cf Custom Stage Data (Prismatic)Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 311.00 262 0 0 312.00 2,200 1,231 1,231 Device Routing Invert Outlet Devices #1 Primary 312.00' 145.0' long x 2.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 3.50 Coef. (English) 2.54 2.61 2.61 2.60 2.66 2.70 2.77 2.89 2.88 2.85 3.07 3.20 3.32 Primary OutFlow Max=3.26 cfs @ 1.25 hrs HW=312.04' (Free Discharge) L1=Broad-Crested Rectangular Weir(Weir Controls 3.26 cfs @ 0.53 fps) BMP Swale #1 BMP #1 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 5 Pond 1 P: BMP Swale #1 Hydrograph C1 Inflow 4.46 cfs ❑ Primary I I I I I I I I I I I TTaI 1ZO4Ir -- -- -- -- -- -- Peak! Ere�r-- 4 Storage= ',1,231 cf 3.35 cfs 3 N U p LL 2 -i-----i-- j---T --j --j-----------i-- j--T--j --j-----------T 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) FES500 Pipe Syste Flow FES 5 0 BMP Swale #2 Subcat Reach on Link BMP Swale #2 BMP #2 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 3 Reach FES500: Pipe System Flow FES 500 Hydrograph I I I I I I I I I I I I I I I I I I I I I I ❑Inflow ❑ Outflow 4.46 cfs--------II-- -- -- -- -- --------I-- Avg. F,10W IIIDph=1 00,' - 4 Marx 1Vel=�.7,'2 fps II II II II II II II II II II II II II II II II II ---I-- -- -- - - ------I-- -- --I----------- -- -- ^ S=0.0042 7' N 2 U 3 -- 0 LL 2 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) BMP Swale #2 BMP #2 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 4 Summary for Pond 2P: BMP Swale #2 Inflow = 4.46 cfs @ 1.05 hrs, Volume= 4.396 of Outflow = 5.91 cfs @ 1.15 hrs, Volume= 7.663 af, Atten= 0%, Lag= 6.0 min Primary = 5.91 cfs @ 1.15 hrs, Volume= 7.663 of Routing by Stor-Ind method, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs / 2 Peak Elev= 312.08' @ 1.15 hrs Surf.Area= 1,740 sf Storage= 968 cf Plug -Flow detention time= (not calculated: outflow precedes inflow) Center -of -Mass det. time= 3.4 min ( 754.1 - 750.8 ) Volume Invert Avail.Storage Storage Description #1 311.00' 968 cf Custom Stage Data (Prismatic)Listed below Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 311.00 196 0 0 312.00 1,740 968 968 Device Routing Invert Outlet Devices #1 Primary 312.00' 100.0' long x 2.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 3.50 Coef. (English) 2.54 2.61 2.61 2.60 2.66 2.70 2.77 2.89 2.88 2.85 3.07 3.20 3.32 Primary OutFlow Max=5.91 cfs @ 1.15 hrs HW=312.08' (Free Discharge) L1=Broad-Crested Rectangular Weir(Weir Controls 5.91 cfs @ 0.72 fps) BMP Swale #2 BMP #2 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 5 Pond 2P: BMP Swale #2 Hydrograph J4.,s ❑Primary Peak'Eilev-3'12.d81 t�rag=�8'e FES200 Pipe Syste Flow FES 2 0 BMP Swale #3 Subcat Reach on Link BMP Swale #2 BMP #3 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 3 Reach FES200: Pipe System Flow FES 200 Hydrograph I I I I I I I I I I I I I I I I I I I I I I ❑Inflow h ❑ Outflow 3.28 cfs-----'-- -- -- -- - ---'---'---'----kvg-Flo,�A/-IDOpth=0�74 - 3 Marx 1Vell=�.72 fps L=12.Q' LL I I I I I I I I I I I I I I I I I I I I 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) BMP Swale #2 BMP #3 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 4 Summary for Pond 3P: BMP Swale #3 Inflow = 3.28 cfs @ 1.05 hrs, Volume= 3.235 of Outflow = 2.46 cfs @ 1.25 hrs, Volume= 2.406 af, Atten= 25%, Lag= 12.1 min Primary = 2.46 cfs @ 1.25 hrs, Volume= 2.406 of Routing by Stor-Ind method, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs / 2 Peak Elev= 309.04' @ 1.25 hrs Surf.Area= 1,750 sf Storage= 987 cf Plug -Flow detention time= 182.9 min calculated for 2.406 of (74% of inflow) Center -of -Mass det. time= 6.0 min ( 756.8 - 750.8 ) Volume Invert Avail.Storage Storage Description #1 308.00' 987 cf Custom Stage Data (Prismatic)Listed below Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 308.00 224 0 0 309.00 1,750 987 987 Device Routing Invert Outlet Devices #1 Primary 309.00' 118.0' long x 2.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 3.50 Coef. (English) 2.54 2.61 2.61 2.60 2.66 2.70 2.77 2.89 2.88 2.85 3.07 3.20 3.32 Primary OutFlow Max=2.40 cfs @ 1.25 hrs HW=309.04' (Free Discharge) L1=Broad-Crested Rectangular Weir(Weir Controls 2.40 cfs @ 0.51 fps) BMP Swale #2 BMP #3 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCADO 10.00-20 s/n 07811 © 2017 HydroCAD Software Solutions LLC Page 5 Pond 3P: BMP Swale #3 Hydrograph 11 Inflow 3.28 cfs ❑ Primary I I I I I I I I I I I T �' 3 $tJ,oraga=987 cf 2.46 cfs w 2 3 0 LL I I I I I I I I I I I I I I I I I I I I I I 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) FES400 Pipe Syste Flow FES 4 0 BMP Swale #4 Subcat Reach on Link BMP Swale #2 BMP #4 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 3 Reach FES400: Pipe System Flow FES 400 Hydrograph I I I I I I I I I I I I I I I I I I I I I I ❑Inflow ❑ Outflow 3.53 cfs /01V�. FlowID p h=0;7g' --II-----I-- -- -- T - - 'I - -'I --'ll -- - -- ---#AarXVe[=�.72fps - 3 S;=0.0042 7 - - I---- - L - - 1 - - L - - L - - L - - - - -I- - -I- 3 2 o � LL I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) BMP Swale #2 BMP #4 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 4 Summary for Pond 4P: BMP Swale #4 Inflow = 3.53 cfs @ 1.05 hrs, Volume= 3.482 of Outflow = 3.46 cfs @ 1.05 hrs, Volume= 3.485 af, Atten= 2%, Lag= 0.0 min Primary = 3.46 cfs @ 1.05 hrs, Volume= 3.485 of Routing by Stor-Ind method, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs / 2 Peak Elev= 311.05' @ 1.05 hrs Surf.Area= 652 sf Storage= 61 cf Plug -Flow detention time= (not calculated: outflow precedes inflow) Center -of -Mass det. time= (not calculated: outflow precedes inflow) Volume Invert Avail.Storage Storage Description #1 311.00' 1,308 cf Custom Stage Data (Prismatic)Listed below Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 311.00 585 0 0 312.00 2,030 1,308 1,308 Device Routing Invert Outlet Devices #1 Primary 311.00' 135.0' long x 2.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 3.50 Coef. (English) 2.54 2.61 2.61 2.60 2.66 2.70 2.77 2.89 2.88 2.85 3.07 3.20 3.32 Primary OutFlow Max=3.44 cfs @ 1.05 hrs HW=311.05' (Free Discharge) L1=Broad-Crested Rectangular Weir(Weir Controls 3.44 cfs @ 0.55 fps) BMP Swale #2 BMP #4 Type/1 24-hr 10-Year Rainfall=5.17" Prepared by Toshiba Printed 1/13/2020 HydroCAD®10.00-20 s/n 07811 ©2017 HydroCAD Software Solutions LLC Page 5 Pond 4P: BMP Swale #4 Hydrograph 11 Inflow 3.53 cfs 10 Primary 3.46 cfs I I I I I I I I I I I I IPeak ElevTT311I 1.051 -----I-- (1 ' 3 to roge=61 e N U 3 2 0 LL I I I I I I I I I I I I I I I I I I I I I I I 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) Skimmer Basin # 1 Calculate Flow - Rational Method 10-Yr Storm 25-Yr Storm Q10 = CIA C= 0.5 Q10 = CIA C= 0.5 1= 7.62 1= 8.46 Q2 = 4.4577 A= 1.17 010 = 4.9491 A= 1.17 Calculate Required Surface Area SA=Q10 x 325 sf/cfs 010 = 4.9491 cfs SA= 1608.458 Side Slopes = 2 :1 Pond Depth= 2 ft Basin Dims Top = 20 x 100 = 2000 sf Bottom = 12 x 92 = 1104 sf Volume Required VR=Ax1800 cf/ac A= 1.17 VR= 2106 Volume Proposed VP=((Top Area + Bottom Area)/2)xD Top= 2000 Bottom= 1104 VP= 3104 D= 2 OK Weir Sizing Per AutoCad Hydraflow Software L= 10 ft D= 1.5 ft dwater= 0.29 ft 025= 4.9491 cfs Velocity= 1.57 ft/s Weir Lining Shear Calculation T=yds y= 62.4lbs dwater= 0.29 ft T= 0.18096 Ibs/ft2 s= 0.01 ft/ft Skimmer Sizing Calculate Dewater Time Qd=V/Td V= 2106 Td= 3 2-5 days typ Qd= 702 Calculate Orifice Diameter D=sgrt((Qd/(2310sgrt(h))) Qd= 702 h= 0.75 D= 0.513012 Use 4 " Skimmer v 0.5 Orifice Skimmer Outlet Protection #7 New York Method 8.06.5 Manual Diameter of Barrel = 4.00 " La= 1.32 Use 7.5 ft Velocity= 2.36 ft/s W= 1 Use 3.0 ft Zone= 1 Stone Diameter= Class A Skimmer Basin # 2 Calculate Flow - Rational Method 10-Yr Storm 25-Yr Storm Q10 = CIA C= 0.5 Q10 = CIA C= 0.5 1= 7.62 1= 8.46 Q2 = 9.9822 A= 2.62 Q10 = 11.0826 A= 2.62 Calculate Required Surface Area SA=Q10 x 325 sf/cfs Q10 = 11.0826 cfs SA= 3601.845 Side Slopes = 3 :1 Pond Depth= 2 ft Basin Dims Top = 35 x 105 = 3675 sf Bottom = 23 x 93 = 2139 sf Volume Required VR=Ax1800 cf/ac A= 2.62 VR= 4716 Volume Proposed VP=((Top Area + Bottom Area)/2)xD Top= 3675 Bottom= 2139 VP= 5814 D= 2 OK Weir Sizing Per AutoCad Hydraflow Software L= 10 ft D= 1.5 ft dwater= 0.47 ft 025= 11.0826 cfs Velocity= 2.07 ft/s Weir Lining Shear Calculation T=yds y= 62.4lbs dwater= 0.47 ft T= 0.29328 Ibs/ft2 s= 0.01 ft/ft Skimmer Sizing Calculate Dewater Time Qd=V/Td V= 4716 Td= 3 2-5 days typ Qd= 1572 Calculate Orifice Diameter D=sgrt((Qd/(2310sgrt(h))) Qd= 1572 h= 0.75 D= 0.767689 Use 4 " Skimmer v 0.8 Orifice Skimmer Outlet Protection #7 New York Method 8.06.5 Manual Diameter of Barrel = 4.00 " La= 1.32 Use 7.5 ft Velocity= 2.36 ft/s W= 1 Use 3.0 ft Zone= 1 Stone Diameter= Class A Temporary Diversion/Berm # 1 => DA # TD 1 Calculate Flow - Rational Method 25-VrStorm Q25=CIA C= 0.50 1= 7.78 in/hr Q25= 3.89 A= 1.00 ac Channel Slope= 1.00 Channel Depth= 1.50 Side Slopes= 3.00 Veloci = 3.90 Soil Tvpe @ am Slopes= 0-10% A Channel Lining Shear Calculation T=yds y= 62.4lbs dwate,- ft T= 0.4056lbs/ft2 s= ft/ft Temporary= Permanent= Temporary Diversion/Berm #111111V => DA # T�-2--1 Calculate Flow - Rational Method 25-VrStorm Q25 = CIA Q25 = 3.42 Channel Slope= 4.00 Channel Depth= 1.50 Side Slopes= 3.00 Veloci = 3.44 Soil Type @ sandy loam Channel Linin¢ Shear Calculation C= 0.40 1= 7.78 in/hr A= 1.10 ac Slopes= 0-10% T=yds y= 62.4lbs dwate,- ft T= 1.19808lbs/ft2 s= ft/ft Temporary= Permanent= Temporary Diversion/Berm # 3 => DA # TD 3 Calculate Flow - Rational Method 25-VrStorm Q25 = CIA Q25 = 1.98 Channel Slope= 1.00 Channel Depth= 1.50 Side Slopes= 3.00 Veloci = 3.90 Soil Tvpe @ am Channel Lining Shear Calculation C= 0.50 1= 7.78 in/hr A= 0.51 ac Slopes= 0-10% T=yds y= 62.4lbs cl.,, ft T= 0.31824 Ibs/ft2 s= ft/ft Temporary= Permanent= Temporary Diversion/Berm #11F4 => DA # Calculate Flow - Rational Method 25-VrStorm Q25 = CIA Q25 = 1.77 Channel Slope= 1.00 Channel Depth= 1.50 Side Slopes= 3.00 Veloci = 3.44 Soil Type @ sandy loam Channel Linin¢ Shear Calculation C= 0.40 1= 7.78 in/hr A= 0.57 ac Slopes= 0-10% T=yds y= 62.4lbs dwate,- ft T= 1.22304lbs/ft2 s= ft/ft Temporary= Permanent= Temporary Diversion/Berm # 5 => DA # TD 5 Calculate Flow - Rational Method 25-VrStorm Q25 = CIA Q25 = 3.50 Channel Slope= 0.50 Channel Depth= 1.50 Side Slopes= 3.00 Veloci = 3.90 Soil Tvpe @ am Channel Lining Shear Calculation C= 0.50 1= 7.78 in/hr A= 0.90 ac Slopes= 0-10% T=yds y= 62.4lbs dwater- 0.72 ft T= 0.22464 Ibs/ft2 s= .005 ft/ft Temporary= Permanent= Temporary Diversion/Berm #11F 6 => DA # Calculate Flow - Rational Method 25-VrStorm Q25 = CIA Q25 = 4.36 Channel Slope= 1.00 Channel Depth= 1.50 Side Slopes= 3.00 Veloci = 3.44 Soil Type @ sandy loam Channel Linin¢ Shear Calculation C= 0.40 1= 7.78 in/hr A= 1.40 ac Slopes= 0-10% T=yds y= 62.4lbs dwate, - ft T= 0.42432lbs/ft2 s= ft/ft Temporary= Permanent= Outlet Protection #1 New York Method 8.06.5 Manual Q= 4.46 cfs Pipe Diameter 12 in La= 5 Velocity= 4.53 ft/s W= 3.75 Zone= 1 Stone Diameter= Class A Outlet Protection #2 New York Method 8.06.5 Manual Q= 4.46 cfs Pipe Diameter 15 in La= 7.5 Velocity= 5.19 ft/s W= 3.75 Zone= 1 Stone Diameter= Class A Outlet Protection #3 New York Method 8.06.5 Manual Q= 3.27 cfs Pipe Diameter 15 ft La= 7.5 Velocity= 6.99 ft/s W= 3.75 Zone= 2 Stone Diameter= Class B Outlet Protection #4 New York Method 8.06.5 Manual Q= 3.52 cfs Pipe Diameter 15 ft La= 7.5 Velocity= 5.31 ft/s W= 3.75 Zone= 1 Stone Diameter= Class A Outlet Protection #5 New York Method 8.06.5 Manual Q= 67.5 cfs Pipe Diameter 60 in (24" & 36"pipes) La= 32 Velocity= 10.25 ft/s W= 12 Zone= 3 Stone Diameter= Class 1 Outlet Protection #6 New York Method 8.06.5 Manual Q= La= 5 W= 3.75 Stone Diameter= Class A 5.15 cfs Pipe Diameter 15 in Velocity= 5.13 ft/s Zone= 1 SHEET FLOW — ✓ \ I \ �G 100 FT I \ / I SHALLOW CONCENTRATED FLOW / \ ✓ \ 957 FT J I CHANNEL FLOIW 721 FT Tc FLOW LINE I (TYP) Tc=22.8 MIN 46.24 AC j II DA#301 2.03AC JI312 '.'.'. ••'.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•••.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•'.•.•.•.•.'.•..'..'.'.'.'.'.'.'.'.'.'.'.•.••'•'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.' /.:'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.� 1 I 0 / I y� .:.:.:.:.:.:.:.:.:.:.�' '..'.;.;;.;.;.•.;.;.;.;.;.;.;.;.;.;.;.;.;.;..;.;.;.;.;.;.;.; I I 1 I I I :.:.:.:.:.:.:.:.:.:.� /� w l I /. I I I A # 2:':':':':':':':':':':':'..':':':':':':':':':':':':':':':'.' 4 1 I 2 AC I I':':':':':':':':':':':':':':':':':':':':':':':':':'.':':':':':':':':':':':':':':':':':':':':':':. .:.:.:: I I / I DA# DA#40 I i 0.68 I I / DSW#1 I 1 I 1.22 AC Is:.:.:.:.:.:.:.:.:.:.:.:.:.:.::.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:...... II I ...............................� o _i I \ I J\ / / / S y3 312 / D W # 4 /1.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:..:.:.'.'.'.'.'.•.•.•.'.:.' I 1 I .. ..... ... .84 A : '::::::'''' \ I I / ................. 1. 7 AC I /•:•:•:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.::•:•:•:•:•:•:':':.:...:.;.;.;.;.;.;.;.;.;.;.;.;.;.;.;.;.;.;.;..: ::::::::::::::::::::::.::::::::::::::::::: I I o0 .:::: I I / I \ I .............. �............................. \ ........... . ........................ ::::: I SW :::::::: / / �- .: I J I ...............................y I / /�I/ \ I I I I I II o 100 0 50 100 200 SCALE: 1" = 200' J THOMAS ENGINEERING, INC. CIVIL ENGINEERING & PLANNING 143 Charlotte Avenue, Suite 104 Sanford, North Carolina 27330 (919) 777-6010 phone www.jthomasengineering.com license no. C-3389 PROFESSIONAL ENGINEER'S SEAL z a 0 WZ i J 20 a o� wa (D2: 3V Q a W 01 zw '—' � �a � a arc ow 0 W0 = z 2:Q cic a IL Z w Oz W z W_ �a � cic W J o Z Z a Z W J REVISIONS AGENCY REVIEW ONLY Scale: Drawn by: 1"=100' MTB Sheet: Designed by: JRT x 18 Reviewed by: 1 RT of Project Number: Date: JTE #:19-017 DDS#: 2019-13 SEPT 2019 U N I I :==: r �: ......... .......: .�. I i r.. i T.�Tr %: i : TTr Tr:. ............rrrrrrrr Tr Tr r T r.........r. rT TTTTTTTTTTTTTTTTTTTTTTTTTT... TTTTTTTTTT �/ Tr✓y DA #TD 2 1.1 AC v �\ • .. . ..:,. —° !i 1 =! 0 •i i' a • ••• / .......... TEGTIO4#2,', Q OUTLET PROTECTION #4 REFER TO SHEET 6 .....Y.T.T.T.T.T.T.TTTTTTTTTTTTTTT %/ OUTLET PRO EC #6 T REFER TO S EET 6 '. .. . _ - T y /T \ v 9 w PA #SK 2 µ.62 AC I_ 20 f=T=. :\ / rr. ,: .. i. .......................... .T A TD 6 �... .T T..................r. T .r. /. . 1. AC T = fir. = �: t / . I. T .....'.'.'.'.'.'.'.'.'.'�.TTTTTTTTT rram.................... . V 1 W is /TrT .................. /.T !' //= / I I z 0 �v 50 0 25 50 50 SCALE: 1" = 50' J THOMAS ENGINEERING, INC. CIVIL ENGINEERING & PLANNING 143 Charlotte Avenue, Suite 104 Sanford, North Carolina 27330 (919) 777-6010 phone www.jthomasengineering.com license no. C-3389 PROFESSIONAL ENGINEER'S SEAL z O _ a 0 W z m i J 20 Ja 0� 0� a �V W 0= zw Ocl� VA o�. Ua O a QW zw p Lu0 = �z 00 a z pz W W W a w oC 1 J 0 z z a z W J REVISIONS AGENCY REVIEW ONLY Scale: Drawn by: 1"=50' MTB Sheet: Designed by: JRT x 17 Reviewed by: J RT of Project Number: Date: JTE #:19-017 DDS#: 2019-13 SEPT 20, 2019 NOTES: 1. WETLAND DE LIN EATED BY OWN ERS CONSULTANT, HAL OWEN&ASSOCIATES, INC DEC. 2003. 2. THE WETLANDS WERE DELINEATED IN 2003 AS PART OF THE ARMY CORP ACTION # 2003-01155. PE WET1AN SDE N 1irvN' PER WET LENDS DELIN FATION SURVEY DEC. 22A2 US COE ACTION# 2003-01155 80.27' I I 436�8_ _ / N870 34' 10"W I — 92.08' l— � 131.18' 50.00' / 303.58' � 78.60' N89° 08' 48"W L N89, 08' 48"W FREIR\N89° 05' 03"W N89° 05' 03"W N89° 06' 05"W N89° 8.6 05"W l ................................... l ;;;;;;;;; ;;;;;;;;;;;;;;;;; S25° 19�30 E �.. .:.................... I I I r..................................................................... t................................................... I / ................... roR�PREs I I / I i /62.6 ..•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.• i �. ( I \ I I / rrW•:•:•:•:•:•:•:•:•:•:•:•:•:•:•:•:•:•:•:•::r':•:•:•:•:•:•:•:•:•:•:•:•:••.•.1vAaLRPCRESEQVE.•.•.•.•.•.•.•.•.•.•.•. 5 \ ° 17' 16 s r>nirs I I 1 j ........... • BIUPLINPS'CP.EAT1•fT]•R ... �: ••:�.•.•.•.•:•••• � . ` o/'cF .•:V 905.. 1s sza 6F I 1 1 / ........... (y (L7\ i "�"'i:.=." "• '.'PFR'USLS3.@UHD'MEP,•,•,• o.ze AC 1•"•• •' ••••• V I 0.32n BLUE LINE TREA (TYP 10.z ) .. 124r]R6 SF ) .. �:.'.' I PER U S QU D MAP GLEN EADOW — j.;.;.;.. :aot169PEREg4(#TS / I \ i as a \ 1 UN/gNAM A:':':':':':':':':':':':':':':':':' •.'.T..;.;.;.;.; ..• UN-WAMEtl.. ..� I 1 RCP CULVE T fI . PY .•4r'•Y�PEi I') 11o,e 1— / / 5b / I :.:.:.:.:.:.:..:.:.:.:.:.:•.;.;.;.;.;.;.;.;.;.;.;.;.;.;.;.;.'.'.'.'.;.4•$4 .*.1;•WCa: 4$;:;:;:;:;.•'•.•.•.......•.•.••....A.. EPTFr.•.•.•.% R\ 1 Ac / / PH I WN{N'� Y�PPR ' ' '/' ' ' ' ': .'.;.'.'.'... W LAND IMP CI AI? #2 / N O /13 w I �' 0 AC .."E 6KARV•STREA"BMAACT � r / � � �.•.•.SfWE1�CiyCRSERM1EWC;f1USCAL'L4TICYU.;• �:• \ /� �J1i � � / //:;:�:�:�:�:�:.�:�:�:�:�:�:�:�:�:�:�:�:�:�:�:�:�:�: n Qf' ................• •........... ;n7R s / :'P1aTilBFSER VE':':':':':'•' 19G2.0 UEKF".'. 1`1 SS W • ••'�'• • i •.•:•:•1�0'iaB04E:pR'.BCP.•. ••. �} ..... W .,-. S / ....... � MFgo S T" I O� :•:;.�:•:•.......•.. 'Rr�"'�rt•$$..... / 1.arPc•.•.•.•.•.•.•.•.•. �t N -ter ..�.-e�.�.•.....•... SS (p .•..... �/ — W� ��� I 'I 320 /�� / / :':'1Nf[C'i CN:•:•:•:•:•:•:•: �f' 315 co W o _ o 72° 45' 07"W I o z3 Ac / 14 — W NEApO ;'4:;' P �, R1*y I f l,•.'.' .'.' / 12,1—F / SLOP STABPLIZATION (T P) —1 Al %YG N� .PR L RY HOVN R •I'.'. / — PROPOSED IjOADtn� / V T �'•'•' •••• •••• 6LE ADOVJ DRIVE TEM RP.RY NAGII ]SBIN ( EGET/#TED) 13 �0 55 � •••• ..•.•.• \ / — — •••• I I I NAME"'•••%:::•••:•••• / PERPNENT VEQETATE (BERM AGRASS) O OCF / w \ ::::•.•. 99osF l M •:•:.:.:.:%.... :o:2sAr T ........_.............................. n e'u�e.Lzme s°mEawr «+� •: •. ry SF o I \// ✓ ..'•..••..;•7.•..:•..:•..::..::..::..::..:•-:.rn.d..:4:.•K .:.Zs:t;•v:•�:'•1.;••••;•:;•:;;.gNpb�U�ds sI:rdb4:NE.A;�3.b;N.A;.n;.e;.OA6:•I•.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:. \/ \ / / MIX RPM MI... ;;;;;;;. .O ej. / / / .• T ...•J.•'....SLOP.E.STA@3LYZATIQN.;]•%P)•.'.'.'.I.AS '� .. I :;:•:;•;.;:;:•.:: P�IR/iRj'NNs.]SBNiVkG£rF'CEDS• ••• •;•.5::':':' :':':':'.;i:'.':':':':'•'• ;.;:•%j\ \ / P �iQY,�:�PGETAt�P:debR«1�phGRA5S1•:'•:•:•:•:•i:`.•'r.?':•:•:•:•:•:•:•:•:•i:;i :•.v l I l I ) sis — / / / . •• G I 1349.79' I I I I I I S88° 38' 31 "E NOTES: 1. WETLAND DELINEATED BYOWNERS CONSULTANT, HAL OWEN&ASSOCIATES, INC DEC 2003. 2. THE WETLANDS WERE DELINEATED IN 2003 AS PART OF THE ARMY CORP ACTION # 2003-01155. 3. WETLAND IMPACTS AS PROPOSED IN THESE CONSTRUCTION PLANS WILL BE PERMITTED BY OWNER'S CONSULTANT, HAL OWEN&ASSOCIATES, INC. NO WORK WITHIN THE WETLANDS SHALL BEGIN UNTIL BOTH US COE PERMIT AND NCDEQ CERTIFICATION IS OBTAINED. WETLANDS SUMMARY TOTAL PROJECT WETLANDS: 203,405 SF (4.67 AC) TOTAL PROPOSED WETLAND IMPACTS: 21,493 SF (0.49 AC) TOTAL PROPOSED STREAM IMPACT: 88 IF TOTAL TEMPORARY STREAM IMPACT: 6 IF 100 0 50 100 200 SCALE: 1" = 100' J THOMAS ENGINEERING, INC. CIVIL ENGINEERING & PLANNING 143 Charlotte Avenue, Suite 104 Sanford, North Carolina 27330 (919) 777-6010 phone www.jthomasengineering.com license no. C-3389 PROFESSIONAL ENGINEER'S SEAL Z 0 a WZ m i J Q OC O 3u W Q 3 G a Q 2 x Z J Q a z W W w o Z a W Y REVISIONS 2019.1120 - USACE Comment AGENCY REVIEW ONLY Scale: Drawn by: 1"=100' MTB Sheet: Designed by: JRT Reviewed by: 3 of 9 JRT Project Number: Date: JTE #:19-017 DDS#: 2019-13 SEPT 20, 2019 0 35o 31' 36" N ■ 705100 705200 Soil Map —Harnett County, North Carolina, and Wake County, North Carolina 705300 705400 70MM 7055600 705700 7058M 1�a,,,.mML_.a■_ I I AL "7%Ik6.C� 1.E w A. ... • D a Ow. - f . rh I Map may not be valid at this scale. 35o 31'14"N 1 y Ie '"1 r...'• .r .1 AL 705100 705200 705300 705400 705500 705600 705700 0 a Map Scale: 1:4,690 if printed on A landscape (11" x 8.5") sheet. ` Myers N 0 50 100 200 300 A0 200 400 800 1200 Map projection: Web Mercator Gomer000rdinates: WGS84 Edge tics: UTM Zone 17N WGS84 USDA Natural Resources Web Soil Survey Conservation Service National Cooperative Soil Survey 705900 1 705800 705900 0 a 706000 35o 31' 36" N a 8 r PW35o 31' 14" N 706000 m a 8/9/2019 Pagel of 4 Soil Map —Harnett County, North Carolina, and Wake County, North Carolina MAP LEGEND Area of Interest (AOI) 0 Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot 0 Landfill A. Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip o Sodic Spot Spoil Area Stony Spot fb Very Stony Spot V Wet Spot 4� Other M� Special Line Features Water Features Streams and Canals Transportation — Rails . 0 Interstate Highways US Routes Major Roads Local Roads Background D6 Aerial Photography MAP INFORMATION The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Harnett County, North Carolina Survey Area Data: Version 15, Sep 10, 2018 Soil Survey Area: Wake County, North Carolina Survey Area Data: Version 17, Sep 10, 2018 Your area of interest (AOI) includes more than one soil survey area. These survey areas may have been mapped at different scales, with a different land use in mind, at different times, or at different levels of detail. This may result in map unit symbols, soil properties, and interpretations that do not completely agree across soil survey area boundaries. Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Oct 29, 2014—Dec 9, 2017 USDA Natural Resources Web Soil Survey 8/9/2019 Conservation Service National Cooperative Soil Survey Page 2 of 4 Soil Map —Harnett County, North Carolina, and Wake County, North Carolina MAP LEGEND MAP INFORMATION The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shiftina of map unit boundaries may be evident. USDA Natural Resources Web Soil Survey 8/9/2019 Conservation Service National Cooperative Soil Survey Page 3 of 4 Soil Map -Harnett County, North Carolina, and Wake County, North Carolina Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI Bb Bibb soils, frequently flooded 4.5 4.0% DoA Dothan loamy sand, 0 to 2 percent slopes 0.2 0.1 % DoB Dothan loamy sand, 2 to 6 percent slopes 31.6 28.3% FaB Fuquay loamy sand, 0 to 6 percent slopes 17.3 15.5% GoA Goldsboro loamy sand, 0 to 2 percent slopes, Southern Coastal Plain 4.9 4.4% Ly Lynchburg sandy loam, 0 to 2 percent slopes 19.7 17.6% NoB Norfolk loamy sand, 2 to 6 percent slopes 4.2 3.8% NoC Norfolk loamy sand, 6 to 10 percent slopes 13.4 12.0% Ro Roanoke loam, occasionally flooded 4.3 3.8% W Water 1.9 1.7% WaB Wagram loamy sand, 0 to 6 percent slopes 2.0 1.8% WaC Wagram loamy sand, 6 to 10 percent slopes 4.8 4.3% Subtotals for Soil Survey Area 108.9 97.4% Totals for Area of Interest 111.8 100.0% Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI FrB Fuquay loamy sand, 0 to 6 percent slopes 1.0 0.9% GoA Goldsboro sandy loam, 0 to 2 percent slopes 0.9 0.8% GrC Gritney sandy loam, 6 to 10 percent slopes 1.0 0.9% RaA Rains sandy loam, 0 to 2 percent slopes 0.0 0.0% Subtotals for Soil Survey Area 2.9 2.6% Totals for Area of Interest 111.8 100.0% USDA Natural Resources Web Soil Survey 8/9/2019 Conservation Service National Cooperative Soil Survey Page 4 of 4 2070000 FEET 2080000 FEET 650000 FEET 78°45'30"W 78°45'0"W 78°44'30"W 78°44'0"W 650000 FEET 262.0 soa w � ' p ' a �eP •_ . � +• �.,-. '�' U r 35°32'0"N 2y3 s •' ,� . UNIINCOO RPORATED AREAS �"'�e� ' � � � 70 68 Ra +, ■ 1• V :. saa 248.9 �'� � • 17' .;�;;� ve i :�` _ Rp � i � - ,v., . _ZI �} ' ryn ..1 � � � � r,il W7!! lilrw:. �, • � _'; ti i y.. .. +' � M � 1� Moore L-n •. • e. '. - •, . ■ - _ a�: _ , r , � +. '1 1 •t a � ' '�'A Tm Q' ya 1 - Angel.Pla¢e44! Ln �yJy r Nerills creek Henderso„ r tLi [. �s- _ _ • c rI. � - �, , � . � �- NG�IIDR_ ETJ •fir ,� �Ha Vh prm _ . . . .,w :; • ,`r Krrrr.��. �,.er'�'� -- �ya�.Ct 7�52;2 ,,� a .. !S� Y 2b2 RNI T UNhNCOO RPORATED AREAS �� '� 35°31'30"N4 If I �i I: ' jr•� 35°31'30"N r Brii iti, eAhe ° �w ;"�•. ti�� �'L�'��Oa•.<a�=�+'► al; ,ma F• r - NGI�ER ETJ ► { + ; y 401 eadom Dr G) � , 4� Or S I E _ 70522 eSt.Rid9e 40* s9 'GIIb..olMor, an i;°ab� ed r i 9 yMcle� n � m Whetstone Dr r " 55�7 Ch'arcoat n 232.E sas ' - .� { f.• A�cn �. Coats;Cir; k' s ') . 'ry m Y �1�+}. Y •,gyp/ /'�( ,`� � ^`�� _ _ � / , _ r h : `A^ ►1 •'1 - • y' E Julia St ' ►t' - 35°31'0"N 35°31'0"N W D '��i f !d �►1 ,., , 1 � ' �[ 'fli++�;e r . ` y51.�.• ..+ f• • t �td,r ' 2 8 upree ono R n E Roy St- _ r K TOO ' • F a�/s, � - � '' Neills aw N �iIl�-SIR ETJ �`I � � of � , Creek Ne+ills Cree-k '' } �. y u. � f J /VJGAG in 228,g Tributes 1 o� 1 .' '►, _' . � • � �} z E Wray St N Y �� 4 d, E "orth st ANGIIER o Dora St �J a W Dora St ram, �!T Black s? o i F • ;y; , ; River ll •� � Ma -ir Lester t cha/yb - a 1. ;sr.. r �•5• I^ T , ..r Jill St ° , - .; 7 x _ L II W Wimberly Sty -,Q 1, Circle Dr-01 Ar �, "W CUttS Sty ! _— Cutt�; St Y 1 Kay Ln R ` 41 �' WS il liFifi I rm t d St' 1� � � E Smithfield St � i w wi//i a 55 ' F m *R 640000 FEET 35°30'30"N - = Z + 35°30'30"N 640000 FEET 78°45'30"W 78°45'0"W 78°44'30"W 78°44'0"W 2070000 FEET 2080000 FEET PEIA6 CC d'•r_ 1,;m rECHNICRLPAFITNEA This digital Flood Insurance Rate Map (FIRM) was produced through a unique cooperative partnership between the State of North Carolina and the Federal Emergency Management Agency (FEMA). The State of North Carolina has implemented a long term approach to floodplain management to decrease the costs associated with flooding. This is demonstrated by the State's commitment to map flood hazard areas at the local level. As a part of this effort, the State of North Carolina has joined in a Cooperating Technical State agreement with FEMA to produce and maintain this digital FIRM. FLOOD HAZARD INFORMATION NOTES TO USERS SCALE SEE FIS REPORT FOR ZONE DESCRIPTIONS AND INDEX MAP THE INFORMATION DEPICTED ON THIS MAP AND SUPPORTING DOCUMENTATION ARE ALSO AVAILABLE IN DIGITAL FORMATAT HTTP://FRIS.NC.GOV/FRIS Without Base Flood Elevation (BFE) With BFE or Depth zone AE, AO, AH, VE, AR SPECIAL FLOOD Regulatory Floodway HAZARD AREAS • 0.2% Annual Chance Flood Hazard, Areas of 1% Annual Chance Flood with Average Depth Less Than One Foot or With Drainage Areas of Less Than One Square Mile Future Conditions 1% Annual Chance Flood Hazard OTHER AREAS OF Area with Reduced Flood Risk due to Levee FLOOD HAZARD See Notes OTHER Areas Determined to be Outside the AREAS 0.2% Annual Chance Floodplain ------------- Channel, Culvert, or Storm Sewer Accredited or Provisionally Accredited GENERAL Levee, Dike, or Floodwall STRUCTURES Non -accredited Levee, Dike, or Floodwall BM5510 X North Carolina Geodetic Survey bench mark BM5510 ® National Geodetic Survey bench mark BM5510<81 Contractor Est. NCFMP Survey bench mark 012 1•$-2— Cross Sections with 1% Annual Chance Water Surface Elevation (BFE) a- - - - - Coastal Transect — - - - - - Coastal Transect Baseline Profile Baseline Hydrographic Feature OTHER Limit of Study FEATURES Jurisdiction Boundary For information and questions about this map, available products associated with this FIRM including historic versions of this FIRM, how to order products or the National Flood Insurance Program in general, please call the FEMA Map Information eXchange at 1-877-FEMA-MAP (1-877-336-2627) or visit the FEMA Map Service Center website at http://msc.fema.gov. An accompanying Flood Insurance Study report, Letter of Map Revision (LOMR) or Letter of Map Amendment (LOMA) revising portions of this panel, and digital versions of this FIRM may be available. Visit the North Carolina Floodplain Mapping Program website at http://www.ncfloodmaps.com or contact the FEMA Map Service Center. Communities annexing land on adjacent FIRM panels must obtain a current copy of the adjacent panel as well as the current FIRM Index. These may be ordered directly from the Map Service Center at the number listed above. For community and countywide map dates refer to the Flood Insurance Study report for this jurisdiction. To determine if flood insurance is available in the community, contact your Insurance agent or call the National Flood Insurance Program at 1-800-638-6620. Base map information shown on this FIRM was provided in digital format by the North Carolina Floodplain Mapping Program (NCFMP). The source of this information can be determined from the metadata available in the digital FLOOD database and in the Technical Support Data Notebook (TSDN). ACCREDITED LEVEE NOTES TO USERS: If an accredited levee note appears on this panel check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1-percent-annual-chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. PROVISIONALLY ACCREDITED LEVEE NOTES TO USERS: If a Provisionally Accredited Levee (PAL) note appears on this panel, check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1-percent-annual-chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To maintain accreditation, the levee owner or community is required to submit the data and documentation necessary to comply with Section 65.10 of the NFIP regulations. If the community or owner does not provide the necessary data and documentation or if the data and documentation provided indicates the levee system does not comply with Section 65.10 requirements, FEMA will revise the flood hazard and risk information for this area to reflect de -accreditation of the levee system. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. LIMIT OF MODERATE WAVE ACTION NOTES TO USERS: For some coastal flooding zones the AE Zone category has been divided by a Limit of Moderate Wave Action (LiMWA). The LiMWA represents the approximate landward limit of the 1.5-foot breaking wave. The effects of wave hazards between the VE Zone and the LiMWA (or between the shoreline and the LiMWA for areas where VE Zones are not identified) will be similar to, but less severe than those in the VE Zone. Limit of Moderate Wave Action (LiMWA) COASTAL BARRIER RESOURCES SYSTEM (CBRS) NOTE This map may include approximate boundaries of the CBRS for informational purposes only. Flood insurance is not available within CBRS areas for structures that are newly built or substantially improved on or after the date(s) indicated on the map. For more information see http://www.fws.gov/habitatconservation/coastal barrier.html, the FIS Report, or call the U.S. Fish and Wildlife Service Customer Service Center at 1-800-344-WILD. CBRS Area Otherwise Protected Area Map Projection: North Carolina State Plane Projection Feet (Zone 3200) Datum: NAD 1983 (Horizontal), NAVD 1988 (Vertical) 1 inch = 500 feet 1:6,000 0 250 500 0 75 150 PANEL LOCATOR 1,000 Feet Meters 300 i CHATHAM COUNTY r 1 0626 _ ✓ \F0604 0624 LEE COUNTY 9548 WAKE COUNTY JOHNSTON COUNTY 0602 1 0622 1 0642 1 0662 1 0682 1 11602 9680 1 0600 1 0620 1 0640 1 0660 1 0680 1 1600 �,.1 1620 9588 1 0508 1 0528 1 0548 1 0568 9566 1 9586 1 0506 1 0526 1 0546 1 0566 9564 1 9584 1 0504 1 0524 HOKE COUNTY i CUMBERLAND COUNTY 1506 1 1 .- 1546 15044 1524 z 7 SAMPSON COUNTY i f; I`f NORTH CAROLINA FLOODPLAIN MAPPING PROGRAM NATIONAL FLOOD INSURANCE PROGRAM cc FLOOD INSURANCE RATE MAP NORTH CAROLINA 0 y. PANEL 0674 x a+vo sti�4 FEMA a Panel Contains: wt� COMMUNITY CID PANEL SUFFIX ANGIER, TOWN OF 370522 0674 K r'r V r HARNETT COUNTY 370328 0674 K WAKE COUNTY 370368 0674 K 0 _0 U. 0 Z MAP NUMBER 3720067400K MAP REVISED 10/03/06 660000 FEET 640000 FEET 2080000 FEET 2080000 FEET rE:3ZSYHi1�i�l re-z'P [d ITiTA rE:�yx�l�►�a� rE:3ty1 INTiTA rE:3Zy11110TI /E:3Z11110111 TJ 78°43'30"W 78°43'0"W 78°42'30"W 78°42'0"W 78°41'30"W 78°41'0"W 78°40'30"W FLOOD HAZARD INFORMATION SEE FIS REPORT FOR ZONE DESCRIPTIONS AND INDEX MAP THE INFORMATION DEPICTED ON THIS MAP AND SUPPORTING F Without Base Flood Elevation (BFE) _ 1 07 With BFE or Depth z-one AL, AU, AN, Vt, AR SPECIAL FLOOD Regulatory Floodway HAZARD AREAS 0.2% Annual Chance Flood Hazard, Areas of 1% Annual Chance Flood with Average Depth Less Than One Foot or With Drainage Areas of Less Than One Square Mile Future Conditions 1% Annual Chance Flood Hazard OTHER AREAS OF Area with Reduced Flood Risk due to Levee FLOOD HAZARD See Notes OTHER Areas Determined to be Outside the AREAS 0.2% Annual Chance Floodplain ------------- Channel, Culvert, or Storm Sewer Accredited or Provisionally Accredited GENERAL Levee, Dike, or Floodwall STRUCTURES I I I I I I I I I I I I I Non -accredited Levee, Dike, or Floodwall BM5510 X North Carolina Geodetic Survey bench mark BM5510 ® National Geodetic Survey bench mark BM5510<81 Contractor Est. NCFMP Survey bench mark 012 1,8-2— Cross Sections with 1% Annual Chance Water Surface Elevation (BFE) a- - - - - Coastal Transect — - - - - - Coastal Transect Baseline Profile Baseline Hydrographic Feature OTHER Limit of Study FEATURES Jurisdiction Boundary NOTES TO USERS For information and questions about this map, available products associated with this FIRM including historic versions of this FIRM, how to order products or the National Flood Insurance Program in general, please call the FEMA Map Information eXchange at 1-877-FEMA-MAP (1-877-336-2627) or visit the FEMA Map Service Center website at http://msc.fema.gov. An accompanying Flood Insurance Study report, Letter of Map Revision (LOMR) or Letter of Map Amendment (LOMA) revising portions of this panel, and digital versions of this FIRM may be available. Visit the North Carolina Floodplain Mapping Program website at http://www.ncfloodmaps.com or contact the FEMA Map Service Center. Communities annexing land on adjacent FIRM panels must obtain a current copy of the adjacent panel as well as the current FIRM Index. These may be ordered directly from the Map Service Center at the number listed above. For community and countywide map dates refer to the Flood Insurance Study report for this jurisdiction. To determine if flood insurance is available in the community, contact your Insurance agent or call the National Flood Insurance Program at 1-800-638-6620. Base map information shown on this FIRM was provided in digital format by the North Carolina Floodplain Mapping Program (NCFMP). The source of this information can be determined from the metadata available in the digital FLOOD database and in the Technical Support Data Notebook (TSDN). ACCREDITED LEVEE NOTES TO USERS: If an accredited levee note appears on this panel check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1-percent-annual-chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. PROVISIONALLY ACCREDITED LEVEE NOTES TO USERS: If a Provisionally Accredited Levee (PAL) note appears on this panel, check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1-percent-annual-chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To maintain accreditation, the levee owner or community is required to submit the data and documentation necessary to comply with Section 65.10 of the NFIP regulations. If the community or owner does not provide the necessary data and documentation or if the data and documentation provided indicates the levee system does not comply with Section 65.10 requirements, FEMA will revise the flood hazard and risk information for this area to reflect de -accreditation of the levee system. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. LIMIT OF MODERATE WAVE ACTION NOTES TO USERS: For some coastal flooding zones the AE Zone category has been divided by a Limit of Moderate Wave Action (LiMWA). The LiMWA represents the approximate landward limit of the 1.5-foot breaking wave. The effects of wave hazards between the VE Zone and the LiMWA (or between the shoreline and the LiMWA for areas where VE Zones are not identified) will be similar to, but less severe than those in the VE Zone. Limit of Moderate Wave Action (LiMWA) COASTAL BARRIER RESOURCES SYSTEM (CBRS) NOTE This map may include approximate boundaries of the CBRS for informational purposes only. Flood insurance is not available within CBRS areas for structures that are newly built or substantially improved on or after the date(s) indicated on the map. For more information see http://www.fws.gov/habitatconservation/coastal barrier.html, the FIS Report, or call the U.S. Fish and Wildlife Service Customer Service Center at 1-800-344-WILD. CBRS Area Otherwise Protected Area SCALE Map Projection: North Carolina State Plane Projection Feet (Zone 3200) Datum: NAD 1983 (Horizontal), NAVD 1988 (Vertical) 1 inch = 1,000 feet 1:12,000 0 500 1,000 2,000 Feet Meters 0 150 300 600 PANEL LOCATOR i CHATHAM COUNTY 1 0626 _ ✓ \F0604 0624 LEE COUNTY 9548 WAKE COUNTY JOHNSTON COUNTY 0602 1 0622 1 0642 1 0662 1 0682 1 11602 9680 1 0600 1 0620 1 0640 1 0660 1 0680 1 1600 �,.1 1620 9588 1 0508 1 0528 1 0548 1 0568 9566 1 9586 1 0506 1 0526 1 0546 1 0566 9564 1 9584 1 0504 1 0524 HOKE COUNTY i CUMBERLAND COUNTY 1506 1 1 .^ 1546 15044 1524 z 7 SAMPSON COUNTY i f; i 2100000 FEET 78°40'0"W 660000 FEET 35°33'30"N 35°33'0"N 35°32'30"N 35°32'0"N 35°31'30"N 35°31'0"N 35°30'30"N 640000 FEET 78°40'0"W 2100000 FEET PEIX, SCC'O"PE�FTII IG TECHNIC.4LPAATIJEA This digital Flood Insurance Rate Map (FIRM) was produced through a unique cooperative partnership between the State of North Carolina and the Federal Emergency Management Agency (FEMA). The State of North Carolina has implemented a long term approach to floodplain management to decrease the costs associated with flooding. This is demonstrated by the State's commitment to map flood hazard areas at the local level. As a part of this effort, the State of North Carolina has joined in a Cooperating Technical State agreement with FEMA to produce and maintain this digital FIRM. NORTH CAROLINA FLOODPLAIN MAPPING PROGRAM NATIONAL FLOOD INSURANCE PROGRAM cc FLOOD INSURANCE RATE MAP NORTH CAROLINA � 0 y. PANEL 0684 x S a�tgNEI SE�4 FEMA n, wcc Panel Contains: t� _~ COMMUNITY CID PANEL SUFFIX ANGIER, TOWN OF 370522 0684 K HARNETT COUNTY 370328 0684 K JOHNSTON COUNTY 370138 0684 K WAKE COUNTY 370368 0684 K 0 _0 U. cc a 0 Z a o x�' Quart v}� MAP NUMBER 3720068400K 10/03/06 D P �wZs - w ri4m?rH CT z rn c o 'L J � Y v_ CIRC M E-SMITHFIELD ST E WILLIAMS_ST �rigle . \E LILLINGTONST, o Q ° -� �L - -ztt e B1'ack'Cr WIMBERLY-RD / Q / / R� 300 1. -44 -� - 1� _1LL