Loading...
HomeMy WebLinkAboutSW4190901_NCDEQ Stormwater Response Letter_1/20/2020January 10, 2020 North Carolina Department of Environmental Quality ATTN: Corey Anen 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 RE: Request for Additional Information Stormwater Permit No. SW4190901 O'Reilly Auto Parts Lexington, NC #3 Davidson County Corey, We received email comments from you on August 15, 2019. Below are responses to your comments: Comment 1: In Part III.4 of the SWU-101 application, please provide the contact information for the local jurisdiction for building permits. Response 1: Contact for local jurisdiction added. Comment 2: In Part IV.10 of the SWU-101 application, each drainage area in the table should represent one SCM. Therefore, the entire drainage area to the sand filter should be presented in one column. Response 2: All drainage areas have been revised. Comment 3: In Part IV.10 of the SWU-101 application, please fill out the second table and provide a breakdown of built -upon area for the site. Response 3: Built upon area updated on all forms. Comment 4: Please complete and resubmit a maintenance plan and agreement using the most up -to- date version of O&M EZ. Response 4: 0&M EZ updated per comment. Comment 5: Please complete and submit a signed and sealed copy of the Supplement EZ form. This can be found on our Stormwater Design Manual website. Response 5: 0&M EZ updated per comment. Signed and Sealed Comment 6: Please provide calculations showing that the outlet from the sand filter is adequately designed to prevent erosion from the 10-year storm [I 5A NCAC 02H .1050(5)]. Anderson EngineeringInc.com 2045 W. Woodland, Springfield, Missouri 65807 • Phone: 417.866.2741 • E-mail: info@andersonengineeringinc.com Response 6: Rip Rap calculations added to stormwater report and rip size updated Comment 7: Please show a maintenance access and easement that meets the requirements of General MDC 8 and 9 [15A NCAC 02H.1050(8) & 15A NCAC 02H .1050(9)]. Response 7: Maintenance easement added to plans. Sending to O'Reilly for description writing. Comment 8: On Sheet Cl. 1, Key Note C 19 should reference Sheet C 1.7 in addition to Sheets C1.10, 1.11, and 1.12 for the sand filter design. Response 8: This has been revised on sheet C1.1 and C1.3. Comment 9: Please provide a detail of the outlet control structure for the sand filter including the inverts of any overflow devices. Response 9: Details of Storm Trap system updated showing outlet box. Comment 10: Calculations must be provided to show that the sand chamber has enough storage above the sand surface to store at least 50% of the design volume and the sediment chamber has enough storage above any permanent pool to store 50% of the design volume. This volume shall be calculated below the invert of the first overflow device. Response 10: Storm Trap details show the required volume on Sheet 1.0 of the design plans. There is no desired permanent pool. SO% of the design volume is in each chamber of the sand filter/sed basin. Comment 11: The sand filet detail on Sheet C 1.7 (StormTrap Sheet 1.0) should show the underdrain pipes and how they will be embedded in the sand layer. Response 11: Underdrains shown on sheet 1.0 and sheet 2.0 of the StormTrap Plans Comment 12: Please provide the design information for the underdrain pipes and calculations to show that they will be sufficient to convey drainage from the sand filter. Calculation guidance can be found in Part B of the Stormwater Design Manual. Response 12: The Underdrains are treated like and orifice. The orifice equaton for the underdrain pipes is included on the 2.0 sheet of the StormTrap plans. Comment 13: Please add a note to the plans that the sand filter must be maintained to have a drawdown of at least 2 in/hour at the sand surface [15A NCAC 02H .1056(8)]. Anderson EngineeringInc.corn 2045 W. Woodland, Springfield, Missouri 65807 • Phone: 417.866.2741 - E-mail: info@andersonengineeringinc.com ANDERSON A' ENGINEERING EMPLOYEE OWNED Response 13: NOTE added to sheet 2.0 of StormTrap plans on sheet C1.7 of plans. Comment 14: Please provide at least one clean -out pipe at the low point of each underdrain line [15A NCAC 02H .1056(9)]. Response 14: Cleanouts added to underdrains on StormTrap sheets. Comment 15: Please provide plans for the Family Dollar to verify built -upon area and proper drainage into the sand filter system. Response 15: We are trying to obtain the plans from the County. At this time is does not appear they are available. Comment 16: Provide pdfs of all revisions, 2 hardcopies of revised plan sheets, and 1 hardcopy of other documents. Pdfs must be uploaded using the form at: https://edocs.deg.nc.gov/Forms/SW Project Submittal Response 16: NOTED. Sincerely, Dylan Gideon P.E. Anderson Engineering ATH/djg Anderson EngineeringInc. corn 2045 W. Woodland, Springfield, Missouri 65807 • Phone: 417.866.2741 • E-mail: info@andersonengineeringinc.com