Loading...
HomeMy WebLinkAboutSW3190505_Form_(Supp.EZ)_20200107SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name COURTYARDS ON LAWYERS ROAD 2 Project Area ac 50.337 3 Coastal Wetland Area ac 0 4 Surface Water Area ac 1.041 5 6 _ w _ Is this project High or Low Density? High No Does this project use an offsite SCM? COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided (feet) 100 8 Will the vegetated setback remain vegetated? _ �� Yes 9 Is BUA other that as listed in .1003(4) c d out of the setback? I Yes I Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Sioretention Cell 0 13 Wet Pond 2 14 Storrnwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater_ Harvesting (RWH) 0 18 Green Roof 0 19 Level Spreader -Filter Stri LS-F5 0 20 Disconnected Impervious Surface (❑IS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 113ayfilter 0 0 26 _ Fiiterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: 28 O anization: 30 ]City, State, Zip: 31 Phone number(s): 32 Email: VINCENT G. KEENE. PE YARBROUG WILLIAMS & HOULE, INC. PO BOX 1198 PINEVILLE, NC, 28134 704-556-1990 VINCEKdiY-WH.COM Certification Statement: I certify, under pen aity of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided In the form is, to the best of my knowledge and belief, true. accurate, and complete; and that the engineering plans, specifications. operation and maintenance agreements and other supporting information are consistent with the information provided here. N11"gJill V11I11118OPP. 'T y SEAL = �.. 6 a7 ,�r''rr rrtrnuti3��al Ignature of DAsigner Date / /.:B /-z' %-,.:;p DRAINAGE AREAS 1 Is this a high density ro'ect? Yes 2 If sp, number of drainage areaslSCMs 2 Is alllpart of this project subject to previous rule 3 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 4 Type of 5CM 5 Total BUA in project [sq ft] 932888 sf 685928 Sf 246960 sf 6 _ New BUA on subdivided lots (subject to permitting] (Sq ft 7 _ New BUA outside of subdivided lots (subject to ermitting)_(�k 8 offsite - total area (sq ft 9 Offsite BU(.Sq to 10 Breakdown of new BUA outside subdivided lots: - Parkin s ft - Sidewalk (sq ft 26222 sf - Roof (sq ft - Roadway sg_ft 193140 sf - Future (sq ft 3500 sf - Other, please specify in the comment box below (sq ft 24098 sf 11 New infiltrating permeable pavement on subdivided lots (sq ft 12 New infiltrating permeable pavement outside of subdivided lots ft 13 Exiskng BUA that will remain {not subject to permittin sg ft}_ Existinq BUA that is a]read y permitted {sq ft} 14 15 Existin BUA that will be removed s R 16 Percent BUA 439b 17 Design storm inches 18 Design volume of 5CM cu ft 19 Calculation method for design volume ADDITIONAL INFORMATION Please use this space to provide any additional information about the 20 drainage area(s): Other for W.P #1 includes clubhouse, parking, pool deck, courts, etc. for future amenity. Other for W.P. #2 includes part of a pedestrian trail. Other for entire site includes future amenity and whole trail. Ex. BUA to remain in O.A. #1 is for portions of ex. Allen Black Road within drainage area. Wet Pond Wet Pond 5$5672 sf 368029 sf 385636 sf 300292 sf 169582 sf 67737 sf 344246 sf 19163 sf 5496 sf 19827 sf 1 3117 sf 64385 sf 17500 sf 1 235 sf 4958 sf 41%Flyr---24hr 9% 2intin 124277 ct037 of lyr-24hr PrelPost Differenceerence Pre/Post WETPOND 1 Drainage area number + 1 2 2}Oasgn volume of SCM (cu ft] 12427�cf43037 If GENERAL MOC FROM DZH .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? *Be Fes Yes 3:1 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H.,V)7 Does the SCM have retaining walls, gabion walls or other engineered 6 side slopes? Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? Is there an overflow or bypass for inflow volume in excess of the design volume? What is the method for dewatering the SCM for maintenance? If applicable, will the SCM be cleaned out after construction? 3:1 No No 7 Yes Yes 8 Yes Pump_ (preferred) Yes Yes 9 Pump (preferred) 10 Yes Yes Yes 11 Does the maintenance access comply with General MDC (B)? Yes 12 131 Does the drainage easement comply with General MDC (9)? If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? Is there an O&M Agreement that complies with General MDC (11)? _ _Yes Yes Yes 14 i Yes Yes 15 is there an O&M Plan that complies with General MDC (12)? Yes Yes 16 Does the SCM follow the device specific MDC? 17TWas the SCM designed by an NC licensed professional? WET POND MDC FROM 02H .1053 18 Method used ^� Yes Yes Yes FDA Yes SAIDA 19 Has a stagelstorage table been provided in the calculations? Ye_s Yes 20 Elevation of the excavated main pool depth (bottom of sediment removal) (fmsl) 051,60 652.50 048.00 21 Elevation of the main pool bottom -(top of sediment removal) (fmsl) 649,00 22 Elevation of the bottom of the vegetated shelf(fmsl} 660.00 662.00 23 Elevation of the permanent pool (fmsl) 660,50 662.50 24 Elevation of the top of the vegetated shelf (final} 661.00 66100 25 Elevation of the temporary pool (fmsl) 663.81 665.65 26 Surface area of the main permanent pool (square feet) 21500 Y7600 27 Volume of the main permanent pool (cubic feet) 120650 of 47925 cf 28 Average depth of the main pool (feet) 6.38 ft 7-12 ft 29 Average depth equation used Equation 3 Equation 3 30 If using equation 3, main pool perimeter (feet) 610,o ft 336.0 ft If using equation 3, width of submerged veg. shelf (feet) 5.0 ft 3.0 ft t31 32 Volume of the forebay (cubic feet) 22175 of 7350 cf 33 Is this 15-20% of the volume in the main pool? Yes y es, 34 Clean -out depth for forebay (inches) 66 in 124277 ti 78 in 43037 Cf 35 Design volume of SCM (cu ft) 36 Is the outlet an orifice or a weir? Orrice Orifice 37 !f orifice, orifice diameter (inches) 5 in 3 in 38 If weir, weir height (inches) 39 If weir, weir iength (inches) 40 Drawdown time for the temporary pool (days) 2 2 41 Are the inlets) and outlet located in a manner that avoids short- circuiting? Yes No Yes 42 Are berms or baffles provided to improve the flow path? No 43 Depth of forebay at entrance (inches) 86 in 98 in 44 Depth of forebay at exit (inches) 66 in 78 in 45 Does water flow out of the forebay in a non -erosive manner? Yes Yes 46 Width of the vegetated shelf (feet) 10 ft B ft 47 §lope of vegetated shelf (HA/) 1 p 1 6.11 _ 48 Does the orifice drawdown from below the top surface of the permanent pool? _ Yes Yes Yes 49 Does the pond minimize impacts to the receiving channel from the 1- yr, 24-hr storm? Yes 50 Are fountains proposed? (If Y, please provide documentation that MDC(9) is met.) No No 51 Is a trash rack or other device provided to protect the outlet system? Yes Yes Y 52 Are the dam and embankment planted in non -clumping turf grass? Yes Yes 5S §pecies of turf that will be used on the dam and embankment —BERMUDA BERMLiDA 54 as a planting plan been provided for the vegetated shelf? i Yes es A0131TIONAL INFORMATION 55 Please use this apace to provide any additional information about the wet pond(s): Wet Pond 1 1:11 PM 2,✓10/2020