Loading...
HomeMy WebLinkAboutSW3191104_2019.10.22-TLE Waxhaw Plans_11/19/2019.z 0 CV CV CV N O U O 77 LU ry 0 J O U CO ry LU O U E2 ' (D (D c— CO I N z� 0 ca X ca LLI J 0 U 0� 00 C� CV 0-) CV ti E2 U N 0 n Iz- (D LU ' Wedbin0tafl t x SITE i4l6rJfll NewTiaa+�n1�� � A a © 2019 Microsoft Corporation © 2019 HERE E:O.r.Q N VICINITY MAP 1 " = 5000' ± - T f r aI . s4 ITE *` 44 �j Y• [•SFr w• ■�� 1 T,4©2. 5 C ONE MAPls- -� N AERIAL VIEW OF SITE 1"=500'± ry CITY GIS / ZONING MAP NOT TO SCALE THE LEARNING EXPERIENCE SITE PLAN PIN NUMBER/PARCEL ID 06156003 1425 PROVIDENCE RD S WAXHAW, NC 28173 0 F� OWNER / DEVELOPER GSG HOLDINGS C/O ELIAS GARCIA 18008 MOLLYPOP LANE CORNELIUS, NC 28031 PH: 704.763.4187 EMAIL: ELIAS@GSGHOLDINGS.COM TOWN OF WAXHAW UNION COUNTY, N.C. GRAPHIC SCALE 50 0 25 50 100 ( IN FEET) 1 inch = 50ft. UTILITIES ELECTRIC: DUKE ENERGY NATURAL GAS: PIEDMONT NATURAL GAS WATER & SEWER: UNION COUNTY PUBLIC WORKS IJL CIVIL ENGINEER CES GROUP ENGINEERS, LLP FIRM LICENSE #: F-1240 274 N. HWY. 16, SUITE 300 DENVER, NC 28037 PH: 704.489.1500 ARCHITECT C.L. HELT ARCHITECT, INC. 6405 WILKINSON BLVD, SUITE 200 BELMONT, NC 28012 PH: (704) 342-1686 X107 FX: (704) 343-0054 VWVW.CLHELT.COM LAND SURVEYOR CAROLINA SURVEYORS, INC P.O. BOX 267 PINEVILLE, NC 28134 PH: 704.889.7601 SHEETINDEX Sheet Number Sheet Title Drawing Revision Number C 0.0 COVER SHEET C1.0 EXISTING CONDITIONS C1.1 DEMOLITION PLAN C2.0 SITE PLAN C3.1 EROSION CONTROL PHASE 1 C3.2 EROSION CONTROL PHASE 2 C4.0 UTILITY PLAN C4.1 SEWER PLAN AND PROFILE C5.0 FINAL GRADING PLAN C6.0 DRAINAGE AREAS C7.0 LANDSCAPE PLAN C8.0 LIGHTING PLAN C9.0 EROSION CONTROL DETAILS C9.1 EROSION CONTROL DETAILS C10.0 SITE DETAILS C11.0 UTILITY DETAILS C11.1 UTILITY DETAILS C12.0 DRAINAGE DETAILS C12.1 DRAINAGE DETAILS A ENGINEERS PLANNERS SURVEYORS SCIENTISTS CES Group Engineers, LLP NC FIRM LICENSE #F-1240 274 N. Hwy. 16, SUITE 300 DENVER, NC 28037 T 704. 489.1500 www.ces-group.net SEAL: O pQR� :ss/ - 041342 = ?, 9N 000000000 SUBMITTALS DATE: PURPOSE: 10/22/19 FIRST COUNTY SUBMITTAL W UM Z00 v` W_N z W3: 0. W W Z C'7 J CO z O X 2 W Z O Z _J � W Q } C J J U) Q ♦ n V U) Q � W = Z D00� W 0 — U co O U d Z W0 O LO W 04 PROJECT NO: 7292 - 0819 DRAWING REVISIONS NO: REVISION DESC. DATE. DRAWN BY: SC REVISED BY: CHECKED BY: TC ISSUED BY: SC DRAWING TITLE: COVER SHEET DRAWING NUMBER: 000 Copyright 2019 CES Group Engineers, LLP 00 0 RIM: 650.76 INV OUT.• 640.11 . ;:7—J) �QV I 6 PIPE Q640 V.• (DO) WMr .76 CO G RIM: 655.52 REBAR \ / / NOTE.• WATER l / IN V.• f 644.4 — — (FOUND LINES / BENT) UNTRACEABLE IN THIS AREA / I ' ) TELE \ / / \ TELE I:OAh1K / to �o / --NOW OR FORMERLY G ��10h T Q UE CHATSWORTH HOMEOWNERS ASSOCIATION INC -NOW OR FORMERLY / / �I DB 504JI756 RICHMOND HILL DEVELOPMENTS LLC �, CO PC 11705 DB 5373/203 ��� / �G Oh RIM: 655.82 ZONED: R-40 LOT 22, PC 11705 p / 1 TCEINV.•f644.6 (DB 7407165) / 20 OAK / -/ 7„OAK � ��� 6 OAK 645 '�� 12 "OAK 6 'OAK / 4 1 - — 'OAK � — — _ 46_/ 65�1,\� 20'%14 "OAK / l 6 »OAK ANGLE IRON /(FOUND) / 7�652 --� ! Jai l FOUND 64 7 OAK ( ) N. C. S. P. C. � � \ �� REBAR / � / — — — -653 — � 14 '0� K � N: 456,771.76 r — — 648 - / - _ ,( / E.• 1, 469, 400.30 — 10 'OAK / 12'/10 "OAK,(FOUND) 652/ S18'1 D 06 W 290.74 — — _8 "OAK- — — — — — 654 8 /� 'OAK LE \ CF_0. 99985572 — 649 -(73. 36)- / / / / 'ice �t 14 "OAK — — — — - ND - 655 12' OAK 6 5 OAK_(217.38) 8 "OAK 1tw 8 „OAK ) 655_ 7'OAK� 8 OAK 8 "OAK WOODLINE �6s �650� 10 OAK F IMF 6 ERLY­ / 655 / — — Z 651 RICHMOND HILL DEVE-NOW OR LOPMENTS LLC \ ✓ \ / /651, /�, / / / / / / 6 / / — _ — — 65,` (DB20 07/65 N w -65s / LOT SSE 21,3PC 11705 / — — / 65 WELL ) o 4Ldk - 652 / / / / / / W HEAD TCE � 4z I _6' K_ — _ 653 (DB 7407165) 10 C659 EXISTING WELL !l� — —654� / / / — _ _ 'OAK �1� 5$/--- —659 --- �' SOAK -654— 11 "OAK_ / / 6 —+10"OAKS t l �655 i i / -w- '14 "OAK 6 „OAK / - 72 'RW 12"OAK — —656- / 659- 660— �78"PINE 661 -_14 "OAK �' 657 / i �660 / / \ 661 o c� p . ��62 6 OAK ��/ -661— 662-� Z o�� — 663--� - -NOW 0�R-FORMERL Y / ~ � � � / I J CHARI�ENE G CARTER / I/�� \ � / / \ i — — i / DB 1232 893 / 662- 10 "PINE 66a 12"CEDAR— - \ \ 14 "OAK / 659 - / / 663 � EC G m HMV _ \ 16 "OAK S14 02'34"W 138.11 CID 10 O� LINE PER PC I/705 � REBAR �6 4 / 6 (FOUND) 663 EXISTING UNDERGROUND — ' REBAR ;h 12 "OAK\ / i TELECOMMUNICATIONS LINE 6...... :::; / / — — .� ,ux.y (FOUND) / -G W 65 I cfl 12 "CEDAR: 9 14 "PINE / 1 — — — / 6 �, 138.12 J , �/ 66 / 664' `- N 10 24'00 E REBAR LINE PER DB (FOUND) APPARENT GAP 67171554 PP6h� — — 6 (0.015 AC.) - w o P:: / / T 666 I rN � 0 I D I / / / WELL j I / / / HOUSE -NOW OR FORMERLY b ��� ./ j / z FANNY CORER MARTINEZ z / / / / / v DB 6717/554 660 8 „ 7„ / BENCHMARK c�a PP D \ OAK / / �y / / NAIL IN PP WM / 667 , /I D _ _ EL V.• 667.85 (NO UG y PIPE / 1 — 8"OAK 8" ,qK — — � � / � � EXISTING UTILITY POLE WITH TRANSFORMER `666(NAVD88) MARKINGS) I � PARTIALLY � — — — / REBAR BURIED n TELE 661 9 "CED R �6� GW PP _ _ — — ✓ \ I o PP — (FOUND) O iPE — OE OE TELE — S17 46 � W 136. 91 (T 11 d5E- _ E _ — ( ' i(FOUND) — — _GAS _ _ \_ _ GAS S _ INV. GAS GAS GPI — — / _ GAS GAS _45= GAS_ _ —GAS � _ EXISTING EDGE OF PAVEMENT — \ 665.13 — N _ —GAS —GAS GqS > C L j--_---—-- _— ---- T T —T-- T / 12"RCP MB-- INV. --- --- ----- —� / 665.07 / 664 / ���) PROVIDEN E ROAD S (60- R.O.W.) \ CP ' \ N1746'08"E 356.90 �INOR ARTERIAL —T FOB — — �— T ——T — T TF T OE OE op- 7 v / i UL- T � T OE - —TECEr -PP---� \ OE c rl 2 GRAPHIC SCALE T 20 0 10 20 40 LF (IN FEET) 1 inch = 20 ft. EXISTING LEGEND , 16=10valI►1d - - RIGHT-OF-WAY LINE EXISTING CURB LINE GENERAL EASEMENT LINE - 722- EXISTING MINOR CONTOUR - 720- - EXISTING MAJOR CONTOUR w w EXISTING WATER LINE _& EXISTING FIRE HYDRANT >a EXISTING GATE VALVE OW EXISTING WATER METER —ss ss� EXISTING SANITARY SEWER PIPE ss EXISTING SANITARY SEWER MANHOLE EXISTING STORM PIPE ® EXISTING CATCH BASIN EXISTING DITCH CABLE EXISTING UNDERGROUND CABLE off off EXISTING OVERHEAD UTILITY LINE ucE ucE EXISTING UNDERGROUND ELECTRIC F0/c EXISTING FIBER OPTIC CABLE c c EXISTING GAS MAIN - — EXISTING FENCE EXISTING UTILITY PLOE BENCHMARK EXISTING SWALE 7 0 0 M r SITE DATA 1.54 ACRES PARCEL/PIN # 6156003 I ADDRESS: 1425 PROVIDENCE RD S WAXHAW, NC 28173 B I REE ZONED: O CZ (OFFICE CONDITIONAL ZONE) FO_L EXISTING USE: VACANT C SITE NOTES \ I 1. TOPOGRAPHIC, BOUNDARY AND EXISTING TREE INFORMATION SHOWN WAS PROVIDED BY CAROLINA SURVEYORS, INC. DATED 5/20/2019 AND REVISED ON 10/07/2019. CID \$ 665 2. PROJECT IS SUBJECT TO ALL APPROVED CONDITIONAL ZONING CONDITIONS PRESCRIBED BY UNION COUNTY ZONING CASE T T — #CZ-2017-007. T W t W fT _ W W W T T= _ T_ _ — — z _— — T 3. EXISTING WELL AND SEPTIC SYSTEM TO BE ABANDONED IN CONCRETE — — — - ACCORDANCE WITH ALL APPLICABLE NORTH CAROLINA LAWS AND €WA — — — — — —� — — — RULES. / / OE OE �- 4. EXISTING ONSITE BENCHMARK: OE 1 / NAIL IN PP ELEV: 667.85 (NAVD88) � SIGN ENGINEERS PLANNERS SURVEYORS SCIENTISTS CES Group Engineers, LLP NC FIRM LICENSE #F-1240 274 N. Hwy. 16, SUITE 300 DENVER, NC 28037 T 704. 489.1500 www.ces-group.net SEAL: 0oo-SS/0°° 00 = 041342 IC-22-Iq _ ° � �\ °p°°°°°°° ., N M. COS \o, SUBMITTALS DATE: PURPOSE: 10/22/19 FIRST COUNTY SUBMITTAL W UM Z I` W00 _N Z1..1� W3: W LLI Z cy J CO Z O X � O 0 Z O Z -J w o � uj O J � w 0 0 () w 02Z w Z (.D0 � — Z U co U z W0 O W� LO PROJECT NO: 7292 - 0819 DRAWING REVISIONS NO: REVISION DESC. DATE: DRAWN BY: SC REVISED BY: — CHECKED BY: TC ISSUED BY: SC DRAWING TITLE: EXISTING CONDITIONS DRAWING NUMBER: Cl 0 ■ Copyright 2019 CES Group Engineers, LLP CZ-2017-007 (TRUFFLE PLAZA) CONDITIONS: 1. MAXIMUM BUILDING HEIGHT SHALL BE TWO STORIES AND IS LIMITED TO 40 FEET 2. A TEN FOOT WIDE BUFFER SHALL BE LOCATED ALONG THE SIDE AND REAR PROPERTY LINES AND THE EXISTING VEGETATION WITHIN THE BUFFER SHALL REMAIN. 3. APPLICANT WILL SUBMIT A PHOTOMETRIC LIGHT PLAN TO UNION COUNTY THE COMPLIES WITH THE LIGHTING STANDARDS OF THE LIDO 4. THE USES ALLOWED ON SITE ARE RESTRICTED TO: 4.1. OFFICE USES 4.2. ANIMAL SERVICES LIMITED TO THE FOLLOWING: 4.2.1. GROOMING OR TRAINING; SUPPLIES; AND VETERINARY, PROVIDED NO OVERNIGHT BARDING OF ANIMALS SHALL BE PERMITTED OTHER THAN AS AN ACCESSORY USE TO A VETERINARY HOSPITAL/CLINIC SUBJECT TO THE FOLLOWING CONDITIONS: 4.2.2. OVERNIGHT BOARDING MUST BE LOCATED ENTIRELY INDOORS; AND 4.2.3. ANIMALS IN OUTDOOR RUNS FOR EXERCISE OR FOR BATHROOM BREAKS MUST BE ATTENDED AT ALL TIMES 4.3. COMMERCIAL SERVICE LIMITED TO THE FOLLOWING: 4.3.1. BUSINESS SUPPORT SERVICE; 4.3.2. COMMUNICATION SERVICE; 4.3.3. RESEARCH SERVICE; 4.3.4. STUDIO, INSTRUCTIONAL OR SERVICE; AND -NOW OR FORMERLY CHATSWORTH HOMEOWNERS ASSOCIATION INC DB 504JI756 PC 11705 ZONED: R-40 / ANGLE IRON (FOUND) N. C. S. P. C. / N: 456, 771.76 E.• 1, 469, 400.30 CF- 0. 99985572 PROPOSED CONCRETE DUMPSTER PAD AND ENCLOSURE. SEE ARCHITECTURAL PLANS FOR DETAILS PROPOSED SEGMENTAL RETAINING WALL HEIGHT VARIES V TO 12'. DESIGN AND DETAILS PROVIDED BY OTHERS PROPOSED STANDARD DUTY ASPHALT IN PARKING SPACES SEE DETAIL ^ I 0 CO 14"OA N W h o 14 "P/ z L IY PROPOSED HEAVY n DUTY ASPHALT S IN DRIVE AISLES V V SEE DETAIL lS V 1 a) I IN V.- 640.26 e0J �O Co RIM: 655.52 INV.• f644.4 RIM: 650.76 INV OUT.• 640.11 6 PI 4- IN �D T Li GRAPHIC SCALE 20 0 10 20 40 (IN FEET) 1 inch = 20 ft. SITE LEGEND SYMBOL DESCRIPTION - - PROPERTY LINE R/W RIGHT-OF-WAY LINE PROPOSED CONCRETE SIDEWALK 71NEW71 PROPOSED ASPHALT PROPOSED PLAY YARD PROPOSED CONCRETE DUMPSTER PAD SITE DATA 1.54 ACRES PARCEL/PIN # 06156003 ADDRESS: 1425 PROVIDENCE RD S WAXHAW, NC 28173 ZONED: O CZ (OFFICE CONDITIONAL ZONE) EXISTING USE: VACANT PROPOSED USE: DAYCARE (CONSIDERED "SPECIAL" USE) REQUIRED PARKING: 1 SPACE PER 500SF 10,500 SF/ 500 SF = 21 SPACES PROVIDED PARKING: 40 TOTAL (30 STD. , 2 ADA, 8 COMPACT) REQUIRED BUFFERS 10 FT. PERIMETER PROPOSED SEGMENTAL RETAINING WALL PROPOSED FENCE ON TOP OF RETAINING WALL T REQUIRED LANDSCAPING / SCREENING: HEIGHT VARIES V TO 11'. SEE ARCHITECTURAL PLANS FOR DETAILS SEE LANDSCAPE PLAN DESIGN AND DETAILS PROVIDED BY OTHERS 14 "OAK S18'10'06"W 290.74 8"0. &AK 8'%O 'OAK LE aiib SITE NOTES 'ice t 14 "OAK ND) 12, "O K K (217.38) 8"OAK 'R' �OA 1. PROJECT IS SUBJECT TO ALL APPROVED CONDITIONAL ZONING CONDITIONS PRESCRIBED BY UNION COUNTY EO 8"OAK ZONING CASE #CZ-2017-007. 2. FUTURE RIGHT OF WAY IS BASED ON CONDITION OF REZONING CZ-2017-007 REQUIRING 20' OF RIGHT OF WAY PLAY EOUip. .................... ...a ................. \ 10 SNOW BE DEDICATED TO NCDOT. o 25' E,4R Y,4FD ..... PEA. Eou P: 4 H...... 3 10� . RICHMOND HlL .-\. .pLAr EOUip.. . 4 h INFANT/TODDLER N ��-'� v DB 3. PROPOSED DAY CARE FACILITY TO BE SERVED BY PUBLIC WATER AND SEWER. °' PLAYGROUND �,... PRE-SCHOOL.. ... RAVEOUP �6. p v LOT . PLAY Ems, p. p`AY EOo`' LAYGROUND 4. DIMENSIONS AND COORDINATE POINTS ARE TO THE FACE OF CURB, EDGE OF PAVEMENT, OR CORNER OF ....... 2,750 SF . . . . . . . . . . . . PLAYA EA T I 6 "OAK W 3,575 SF' BUILDING UNLESS OTHERWISE NOTED. ....................... ............... cn 10 "OAK NC.. S1 E.WALK> 5. ALL IMPROVEMENTS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH STATE AND LOCAL STANDARDS. 3 3 0 "0 ` 6 L BE CALLED TO THE ATTENTION OF THE OWNER OR I 8 OAK ANY DISCREPANCIES FOUND IN THE FIELD SHALL 125' -� 110"OAK \14 OAK aft 6 " OAK ' ENGINEER PRIOR TO PROCEEDING WITH WORK. PROPOSED SEGMENTAL 1K ❑ ❑ \ RETAINING WALL 7. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS HEIGHT VARIES 1' TO 12'. AND APPROVALS FROM ALL REGULATORY AUTHORITIES. DESIGN AND DETAILS 24' 19, cn.. 8. THE GENERAL CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, UTILITIES AND RIGHT-OF-WAYS, PROVIDED BY OTHERS ? �l� PUBLIC AND PRIVATE, PRIOR TO WORKING IN THESE AREAS. / o... \ \y 6"OAK (z) m 9. GENERAL CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMAN AND THE PUBLIC SHALL BE PROTECTED FROM INJURY. m N R.. ��I� j PROPOSED FENCE (TYP) 10. MAINTENANCE OF TRAFFIC DURING CONSTRUCTION SHALL BE IN ACCORDANCE WITH NCDOT STANDARDS E.c::. rE PROPOSED DAYCARE 10,584 S.F. Co. INE� SEE ARCHITECTURAL PLANS FOR DETAILS AND SPECIFICATIONS. o VAN ACCESSIBLE : �J. \� 16�0 K S14 02'34"W 138.11 BARRIER FREE I .' a� 11. DO NOT SCALE DRAWINGS FOR ACTUAL DIMENSIONS, AS IT IS A REPRODUCTION AND SUBJECT TO PARKING SIGN RAR 10. "OAK LINE PER PC I/705 DISTORTION. ti w .......(' UND) 0 m ? I- I 12 "OAK ii� 12. ALL SIGNS PAVEMENT MARKINGS AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE .............. .,::: ....:...'.:..'.'...'.'...... :':::...:'.'.'.:.. ";..6 'MAPLE'..:;.:`......:'..... GI/1/:. '� }I r.y.....,..'.'. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES MUTCD , 2009 EDITION AS AMENDED. Om > .(9`. ' I cfl 12 CEDAR.:.'......' . �� ( ) z � Z . ---- a PLAY AREA. » 138.12 S O:. 4,006 SF 10 N10 24 o PER pB 13. ALL PAVEMENT MARKERS SHALL BE FOUR (4) INCHES WIDE UNLESS INDICATED OTHERWISE ON DRAWINGS. E3.. _J 'p REBAR LINE FUTURE 25' I (FOUND) APPARENT GAP 67171554 14. CONTRACTOR SHALL FURNISH AND INSTALL ALL PAVEMENT MARKINGS AS SHOWN ON THE PLANS. 6' <. 5.7' I 38.3' . FRONT YARD PROPOSED 8•X8• CONCRETE PAD 15. CONTRACTOR SHALL SAW -CUT EXISTING ASPHALT PAVEMENT AREAS TO TIE IN SMOOTHLY TO PROPOSED a, 26' FOR DUKE ENERGY TRANSFORMER PAVEMENT AT DRIVEWAY ENTRANCES. 8 8 WALK O I WELL : �n �n - HOUSE 16 ACTUAL BUILDING DIMENSION RASH ENCLOSURE DETAIL REFER TO ARCHITECTURAL PLANS FOR S, T S, UTi -NOW OR FORMERLY Lo zn. ... ... �i ao FENCING DETAILS, SIGNAGE DETAILS. N N O0 FANNY CORER MARTINEZ 2 PROPOSED CROSSWALK o FUTURE 10' BUFFER v DB 67171554 D SEE DETAIL FUTURE BENCHMARKF TURE 00 17. CONTRACTOR SHALL COORDINATE CONSTRUCTION AND LOCATION OF SIDEWALKS, STOOPS, STEPS, 8 7" ca HANDRAIL, AND ACCESS DOORS WITH ARCHITECTURAL PLANS. OAK R/W R/W R/W R/W R/W R/W R/W /W R/W R/W z PROPOSED 5' CONCRETE SIDEWALK - NO '� Ic a S PROPOSED 6 CONCRETE SIDEWALK EL V. 667.85 ( UG .� W PIPE 18. COORDINATE SIDEWALK AND SCORING PATTERNS ADJACENT TO THE BUILDING WITH THE ARCHITECTURAL i 8"OAK 8" AK o + � (NAVD88) MAIo, NGS) � PARTIALLY PLANS. 11 N : , NMr BURIED n TELE E R y: 19. ENT L PIPE rn ".'a �- S17 46W 136.91 (TIE) VENDOR FOR ALL PLAYGROUND EQUIPMENT AND PLAY SURFACES. PLAYGROUND EQUIPMENT AND FOUND) - SURFACES TO BE PROVIDED AND INSTALLED BY REQUIRED VENDOR. NO SUBSTITUTIONS ALLOWED. �i =MJW7.5 PO9FFWNUfflFW1tIG GAS GAS GAS GAS GAS - GAS GAS- GAS G S GAS GAS 150' TAPER (CONTINUES OFF SHEET) AS GAS -50, 50' 665.13 150' TAPER 20. CONTRACTOR TO ENSURE PROPER DRAINAGE FOR PLAYGROUND AREA, SO ABOVE GRADE AND BELOW ��'�; ��h N GRADE "PONDING" WILL NOT OCCUR. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING AT 1/8" TO 1/4" r PER FOOT PITCH. NO ROOF DRAINS TO EMPTY DIRECTLY INTO PLAYGROUND. ir _ PROV DEN E ROAD S (60- R.O.W.) 21. PROPOSED PLAY YARD SURFACE AREAS TO CONSIST OF SYNTHETIC TURF AND POURED IN PLACE RUBBER SURFACING. CID ° CID22. CONTRACTOR SHALL PROVIDE NECESSARY TRASH COLLECTION AND DISPOSE TO A LEGALLY APPROVED N1746'08"E 356.90 INOR ARTERAPH LANDFILL. POST D SPEED = T T T T T 23. STOP BEFORE YOU DIG. CALL NC ONE -CALL CENTER AT 811 OR 1-800-632-4949. W - W W W W SEE NCDOT ROADWAY - 24. PLAY AREA EQUIPMENT SHOWN IS APPROXIMATE AND FOR CONCEPTUAL PURPOSES ONLY. n "KEEP RIGHT" MEDIAN SIGN 4' WIDE CONCRETE ISLANDJ LEFT TURN PROHIBITION SIGN T T T T CONCRETE IMPROVEMENT PLANS e- T _ R4-7 NCDOT STD #852.01 R3-2 T _ €WA FE�� - - TECE- r - "KEEP RIGHT" MEDIAN SIGN r - OE - OE- R4-7 OE OE L L 7 7 L PROPOSED) (( PARKING AREA 18" CONC. CURB & GUTTER i' TYPICAL 4.3.5. PERSONAL IMPROVEMENT SERVICE WITHOUT THE NEED TO APPLY FOR A SPECIAL USE PERMIT 4.4. DAY CARE CENTER WITHOUT THE NEED TO APPLY FOR A SPECIAL USE PERMIT 4.5. SELF-SERVICE STORAGE FACILITY LIMITED TO TYPE 1 5. ACCESS TO THE SITE WILL BE PROVIDED BY ONE DRIVEWAY OFF OF PROVIDENCE RD 6. TWENTY FEET OF RIGHT-OF-WAY WILL BE DEDICATED TO NCDOT FOR THE PROVIDENCE RD WIDENING 7. BUILDING MATERIALS ARE RESTRICTED TO: GLASS, BRICK, STONE, SIMULATED STONE, PRE -CAST STONE, ARCHITECTURAL PRE -CAST CONCRETE, SYNTHETIC STONE, STUCCO, CEMENTATIOUS SIDING OR WOOD 8. EIFS AS A BUILDING MATERIAL IS NOT ALLOWED EXCEPT AS A BACK UP FOR ARCHITECTURAL TRIM ON STUCCO CLAD BUILDINGS 9. VINYL AS A BUILDING MATERIAL WILL ONLY BE ALLOWED ON WINDOWS, SOFFITS AND TRIM FEATURES 10. METER BANKS WILL BE SCREENED FROM PUBLIC VIEW AND PUBLIC STREETS 11. ROOFTOP HVAC AND MECHANICAL EQUIPMENT WILL FROM PUBLIC VIEW AND PUBLIC STREETS 12. ALL DUMPSTER AREAS SHALL BE ENCLOSED BY WALLS AND OPAQUE GATES UTILIZING MATERIALS SIMILAR IN NATURE TO THE BUILDINGS 13. ALL SERVICE AREAS FOR NON-RESIDENTIAL USE SHALL BE SCREENED FROM RESIDENTIAL STRUCTURES 14. ON -SITE LOADING DOCKS AND WASTE AREAS SHALL BE SEPARATED AND/OR SCREENED FROM VIEW AT GROUND LEVEL FROM PRIMARY BUILDING ENTRANCES AND FROM PUBLIC VIEW 15. STREET TREES WILL BE PROVIDED WITHIN PLANTING STRIPS ALONG THE PUBLIC STREET 16. DEVELOPMENT SHALL COMPLY WITH THE SUBMITTED CONCEPTUAL PLAN 17. THIS PETITION INCLUDES VESTING OF THE APPROVED REZONING PLAN FOR A FIVE YEAR PERIOD PROPOSED DROP CURB FOR PLAYGROUND DRAINAGE -NOW OR FORMERLY RICHMOND HILL DEVELOPMENTS LLC DB 5373/203 LOT 22, PC 11705 TCE (DB 7407165) 4ER UWM640(2) N UNE INA CO RIM: 655.82 INV.• f644.6 AA arauP ENGINEERS PLANNERS SURVEYORS SCIENTISTS CES Group Engineers, LLP NC FIRM LICENSE #F-1240 274 N. Hwy. 16, SUITE 300 DENVER, NC 28037 T 704. 489.1500 www.ces-group.net SEAL: \�,%%1111filli,�, ,' N CARP '% OP�Fs/o Es _ 041342 N c� / NEAP 000o0000 SUBMITTALS DATE: PURPOSE: 10/22/19 FIRST COUNTY SUBMITTAL W UM Z I` W00 _N N L.L Z W3: Q w Z ci CO z = d J O 0 W 0 Z O Z C)J J o v Q � w = 02LU w cD 0 O - Z U 00 U Z O W0 W� LO PROJECT NO: 7292 - 0819 DRAWING REVISIONS NO: REVISION DESC. DATE: DRAWN BY: SC REVISED BY: CHECKED BY: TC ISSUED BY: SC DRAWING TITLE: SITE PLAN DRAWING NUMBER: C200 ,opyright 2019 CES Group Engineers, LLP STRUCTURE TABLE STRUCTURE DETAILS: PIPES IN: PIPES OUT RIM = 662.70 DI-5 INV IN = 657.37 12" HDPE INV=657.37 15" RCP INV=657.27 INV OUT = 657.27 RIM = 662.15 DI-7 INV IN = 658.46 6" HDPE INV=658.46 8" HDPE INV=659.00 INV OUT = 659.00 RIM = 661.48 DI-6 12" HDPE INV=658.26 INV OUT = 658.26 RIM = 661.06 CB-4 INV IN = 655.44 15" RCP INV=655.44 15" RCP INV=655.34 INV OUT = 655.34 RIM = 660.17 CO-7A 6" HDPE INV=659.60 INV OUT = 659.60 RIM = 658.49 15" RCP CB-3 INV OUT = 654.02 INV=654.02 RIM = 658.42 CO-2A INV IN = 657.25 8" HDPE INV=657.25 8" HDPE INV=657.25 INV OUT = 657.25 RIM = 647.57 HW-1 18" RCP INV=650.40 INV IN = 650.40 TOP = 657.58 15" RCP INV = 653.00 SF-2 INV IN = 653.00 15" RCP INV = 655.00 18" RCP INV = 651.00 INV OUT = 651.00 8" HDPE INV = 656.00 8" HDPE INV = 656.00 �c C r1 IN V.- 640.2 "2 l 00 o� O RIM: 650.76 6 INV OUT.• 640.11 o .;:7- J) \J EXISTING 850 X8-14•60 XB/C874 60 �NlXB/w 883.5A 0 �QJ 6 P/PE INV.• %U) WM/ w l 640.76 \ (2) CO 1z RIM: 655.52 1? / NO TE: WA TER INV. f 644. 4 (F0 ND LINES / - - NT) UNTRACEABLE IN THIS AREA / I ' ) TELE \ / TELE / I "OAK / rxo Gil '1����oh�_ Q �" UE -NOW OR FORMERLY RICHMOND HILL DEVELOPMENTS LLC 1 I �' G �, CO DB 5373/203 I �S �G Oh RIM: 655.82 LOT 22, PC 11705 , p ' I1 TCE f644.6 (DB 7407165) 20 "OAK 7"OAK 6"OAK 12 "OAK 6 "OAK 7'OAK / /.20'/74"OAK l - _ 6q6 PROPOSED SEGMENTAL RETAINING WALL _4 "OAK 653') - - DESIGN AND DETAILS PROVIDED BY OTHERS PROPOSED PERFORATED HDPE UNDERDRAIN / ANGLE IRON SYSTEM WRAPPED WITH GEOTEXTILE FABRIC -647' SEE NOTE 17 (FOUND) PROPOSED UNDERGROUND PRECAST N. C. S.P. C. EECONCRETE SAND FILTER PROPOSED SWALE - 14 0 "OAK 65 1.76 r - -648 ��� �'re r"PROPOSED @ 0.7/o SLOPE i PROPOSED CLASS B 70"OAK 12'/70"0AK OUND 70 os w 290 74 -8'/ o"oAK GRADING AND DRAINAGE NOTES: GRAPHIC SCALE 20 0 10 20 40 (IN FEET) 1 inch = 20 ft. LEGEND PROPOSED \� 850 --- CONTOUR WITH ELEVATION Xg-74 60 SPOT ELEVATION X5IC S74 60 BACK OF CURB SPOT ELEVATION xv\N $g3 j$ TOP OF WALL SPOT ELEVATION xel`N $g3 51 BOTTOM OF WALL SPOT ELEVATION CONCRETE CURB & GUTTER - - PROPERTY LINE ❑ CATCH BASIN / CURB INLET STORM DRAIN AND ENDWALL SS SANITARY SEWER SANITARY MANHOLE NCO CLEAN OUT w WATER MAIN OR SERVICE LINE OH/U OVERHEAD UTILITY LINE FIRE HYDRANT GATE VALVE Gc_ ' POWER POLE GUY AND ANCHOR CANOPY TREE TO REMAIN RETAINING WALL RIPRAP APRON 4 0 `� ) DROP CURB - -8 "OAK -V` LE G ur. v. y y98557 - - FLUSH WITH ASPHALT a� - - - 5 72 "OAK 64g ^ _(73 3R )� T/C 662.08 rdk 14 OAK - ND) - 65 � - BNV649.84 / PROPOSED CLEANOUT 5 OAK_-(21 .,38) 8"OAK 'R' � / 6"9` / TNV 660.75�I0' BUFFER �'' B/W 651.51 �- �F� 8 OAK / 1. EARTHWORK QUANTITIES HAVE NOT BEEN ESTIMATED AND SITE AS SHOWN IS NOT ASSUMED TO REPRESENT A _ /7 i rsivv oo .o I BNV 655.1.5 B/W 655.45 B/W 655.26 BALANCED CUT / FILL CONDITION. 650, T/C 660 2 / T/W 662.54 65 T/W 663.14� _ TNV 662.68 T/W 662.25_ / 2. CONTRACTOR SHALL PERFORM HIS OWN ESTIMATE AND SHALL PROVIDE ALL EARTHWORK NECESSARY TO TNV 661.81 ° 173 LF - 8" HDPE 1.01% HW-1 20 LF - 18" RCP @ 2.99 /o CO-2A @ s5�\ ✓ BNV 650.52 I / 25' REAR YARD - DI-7 S 42 TNV 660.37 TIC 660 - / 30 LF - 8" HDPE @ 4.12% - DB 7407 5 \ BNV 651.77 / / T/C 660.3 661/0 656 - ( ) 6` TNV 660.00 °° ��C1066�°'9 /662g 663 / I 6 63� TCE o I ww T/C 659.73,..... 66�7 O n- �r...i�rr....�. '�" L..ry'" � ' '��; �' :�� : ,riryn.``.i�:..r�r,' 6 666 6' 66 '. ' 66 660 00. 17 LF - 15 RCP o6 9., `..' '.. -654- 0s @ 2.00% V 662.51 G '\\<�6 66?2 T/C �W SEE ARCHITECTURAL PLANS PROPOSED 220 LF 8" HDPE 6 \ 41 - FOR DOWNSPOUT DETAILS @ MIN 1.0% SLOPE i w 1 12'OA� 6SS-co 0 6 I 47) T/C 661 /n 6S9 51 LF - 15" RCP of (�`' CB-4 80 @ 2.00% n o6o Goo N I�� �ootiPROPOSED 37 LF 6 HDPE - 6, 6S6 CB-3 / �1 �1 r TIC 663.01�co @MIN 1.0% SLOPErn 2I 0 -� T/W 659.07 I C- ADA RAMP °� @ BNV 656.25 �,N �^ ` 7 l 66 w \ o / �o� I ��oi ���. SEE DETAIL ,66 'LH PROPOSED DAYCARE - FFE = 663.25 ��'25 0 T/C 663.01 O PROPOSED 35 LF 6" HDPE Et 663.01 0 0 � @MIN 1.0 /o SLOPE M \ -m _ cfl s9 0) 74"P1_ 00� - n PROPOSED DOWNSPOUT S6: i CONNECTION TYP - oh oo. 0 w I ti� ( ) PROPOSED 178 LF 8" HDPE - o 0 / 003" SEE DETAIL @ MIN 1.0% SLOPE 666 o BNV 658.99 C66 ^ FUTURE 25' 31 1 1 1 1 66 O FRONT /,\ - " lO 1 663 T/W 660.00? 663.2 66g2 66g2 �'7 '. f 3S : 1 I F o9 DI-5 6 '- 0 1!6,9 �660 jG66� �?84 6'rr-.6-os @ 3W 663 3; 3'89WW 66AW 60 3 W 3 W E %100M < < </2 662660 661ggFUTU R/W R/W 663' DI-6 BE CH lW R665 eVW OAK 6 6sPROPOSED GRASS SWALEgg4664 F/ R/W 85 66 8 „OAK 660 248 „ AK - - 6628a- 66 Lo6�,`' �o� oo� ° 665 / 665.44 665.80 �651 -NOW ACHIEVE THE DESIGN GRADE, INCLUDING ANY OFFSITE BORROW OR SPOILS REQUIRED. Z RICHMOND HI 3. CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE IN ALL GRADED AREAS, INCLUDING PAVING, LAWN AND PROPOSED 12" NYLOPLAST DRAIN DB N v BASIN WITH PEDESTRIAN GRATE LOT . LANDSCAPE AREAS. o v SEE DETAIL 4. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO THE OWNER ANY DISCREPANCIES FOUND BETWEEN T/W 662.52 � 70"C65 ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTIONS PRIOR TO BNV 658.55 j� � PROCEEDING. 'OAK ,t 5. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO BEGINNING WORK, BOTH I 'low �� 8 OAK PUBLIC AND PRIVATE. CONTRACTOR IS FULLY RESPONSIBLE FOR ALL UNDERGROUND UTILITIES AND SHALL 110 'OAKS `0-7 4 "0AK 6 "OAK REPAIR ANY DAMAGE AS A RESULT OF THIS CONTRACT. \ 72"OAK _% 6. CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. � 78"PINE 661- 7. THE PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN IN DRIVES, PARKING LOTS AND SIDEWALKS ARE -� FINISHED ELEVATIONS INCLUDING ASPHALT. REFER TO PAVEMENT CROSS SECTION DATA TO ESTABLISH 10 4-74"OAK n o (BNV 661.420 . \662 \ y 6 CORRECT SUBBASE OR AGGREGATE BASE COURSE ELEVATIONS TO BE COMPLETED UNDER THIS CONTRACT. TNV 662.8 v 8. ALL "STD." NUMBERS REFER TO THE NCDOT OR UNION COUNTY STANDARDS. �- 9. ON -SITE BURIAL PITS REQUIRE AN ON -SITE DEMOLITION LANDFILL PERMIT FROM THE ZONING ADMINISTRATOR. c� 0 10. PIPE LENGTHS SHOWN ARE THE ENGINEER'S ESTIMATE USED TO COMPUTE PIPE SLOPE AND INVERTS AND / "P10y SHALL NOT BE CONSTRUED BY THE CONTRACTOR TO REPRESENT THE ACTUAL QUANTITY OF PIPE REQUIRED. lNE� 0`42"CEDAR - ` ; 1-6 \v 11. MAXIMUM CROSS SLOPE OF SIDEWALKS SHALL BE 1/4 /FT. \ 6 "OA S14 02'34"W 138.11 12. SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. W/ OUT ADDITIONAL STABILIZATION MEASURES AND PRIOR (R 70'OAK LINE PER PC V705 APPROVAL. 13. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD 12 "OAK I.� CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY 2 CEDAR.::.:::'..... ° 4'00"E 13 REBAR PER 8.12 OWNERS. N10 2 pB 14. ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS I/rn/ /A/n) A Do A OEN T GAP LINE 6717/554 WATERTIGHT. 5 AC.) PROPOSED CLEANOUT 15. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC �v.v1 O- BEARING RING AND COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 61, ABOVE FINISH GRADE. LIDS SHALL W CO-7A BE LABELED "STORM SEWER". WELL M cD HOUSE 16. RIM ELEVATIONS OF CURB INLET EQUALS THE FLOW LINE OF GUTTER PAN, NOT THE DEPRESSED ELEVATION AT CO co -NOW OR FORMERLY THE INLET. FANNY CORER MARTINEZ D v DB 67171554 17. ALL PROPOSED CONTOURS IN ALL "FILL" AREAS SHOWN ON THIS PLAN REPRESENT COMPACTED STRUCTURAL FILL AND SHALL BE CONSTRUCTED WITH SATISFACTORY MATERIAL COMPACTED TO THE STANDARDS OUTLINED 00 IN THE SPECIFICATIONS. PIPE 18. RCP PIPES SHALL BE CLASS III RCP UNLESS OTHERWISE NOTED. PAR TIALL Y 6.52 BURIED 19. ALL STRUCTURES AND GRATES SHALL BE COMPLIANT WITH THE MOST RECENT NCDOT STANDARDS AND BE TELE,, 1 O . 7 o " ; .. TRAFFIC BEARING AND RATED HEAVY DUTY UNLESS LOCATED OUTSIDE OF A PAVED AREA. 6 � 6 _ FCJUND-: 6.42 5 6 _ 6 APE " .....:.' .......:...:.........: :.: '..'. ... - 66 - 66�3g 66539 665.75 S17 46 "W 136 91 (TE) - OE ��_ �E� 20. RETAINING WALL TO BE SEGMENTAL WALL. CONTRACTOR TO SUBMIT STRUCTURALLY ENGINEERED PLANS TO I(FOUND) 4 - - - - - IX _ _ THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION. < _ _ 663 ifl o G66 n \ \ GAS SAS 21. UNDERDRAINS SHOWN ARE FOR PLAYGROUND AREA. GAS _ _ �s6, SAS < - < �A 6 _ Tj�� 66s �� _ GAS GAS > > > - > �66^ GAS GAS - - - GP�S -� - - - _ C664s3 - - - - - -�- - o- - - / O > - > - > - _ -_ >co - C _ 22. ALL HDPE PIPE SHALL BE ADS N12 TYPE S OR APPROVED EQUAL. 23. PROPOSED UNDERDRAIN SYSTEM TO BE COORDINATED WITH SYNTHETIC TURF MANUFACTURER AND/OR �- ADA RAMPS l SUPPLIER. PROPOSED GRASS SWALE SEE DETAIL �/ PROVIDENCE ROADS (60' R.O.W.) PROPOSED GRASS SWALE CP CP N1746'08"E 356.90 MINOR ARTERIA V - V - n FOB - �. T T _ _ T L - L OE L 7 7 7 II OE W- T T=� OE / -- / ✓ W W _W _ T --- T T- CONCRETE T T T= T -TECH - - € WA OE PP OE 1 OE / OE I • • I Know what's below. Call before you dig. NORTH CAROLINA ONE -CALL CENTER INC. DIAL 811 or1-800-632-4949 2 BUSINESS DAYS BEFORE DIGGING www.ncocc.org .,.Iiiiim arauP ENGINEERS PLANNERS SURVEYORS SCIENTISTS CES Group Engineers, LLP NC FIRM LICENSE #F-1240 274 N. Hwy. 16, SUITE 300 DENVER, NC 28037 T 704. 489.1500 www.ces-group.net SEAL: \\,1111111111//'1 "1,0N CARP< '% o� 0P essro 0 _ 041342 Ck N cc'�a/NEAP 000o00.0 SUBMITTALS DATE: PURPOSE: 10/22/19 FIRST COUNTY SUBMITTAL W UM Z I` W00 _N Z W3: 0. Q W Z cY) Z _ O 0 Z O Z 0 J J 0 v C) � W = 02Z w c O - z U�o� 0o U Z O W0 LO PROJECT NO: 7292 - 0819 DRAWING REVISIONS NO: REVISION DESC. DATE: DRAWN BY: SC REVISED BY: CHECKED BY: TC ISSUED BY: SC DRAWING TITLE: FINAL GRADING PLAN DRAWING NUMBER: C500 copyright 2019 CES Group Engineers, LLP fc c rl TELE Y IN V.- 640.2 co SSMH RIM: 650.76 \ 6 INV OUT.• 640.11 Eim GRAPHIC SCALE T 20 0 10 20 40 ( IN FEET) LF 1 inch = 20 ft. 00 �Q� 6 PI PE / 1 1 I NV. (DO) WM/ .76 \ (2) / EXISTING CO G / 850 RIM: 655.52 REBAR \ / / NOTE.• WATER l / IN V.• f 644.4 - - (FOUND LINES / BENT) UNTRACEABLE IN- ' _ THIS AREA / I ' ) TELE \ / El a"� � G�, h1 TELE I "OAK / --NOW OR FORMERLY G ��10h T Q UE CHATSWORTH HOMEOWNERS ASSOCIATION INC -NOW OR FORMERLY DB 5043/756 RICHMOND HILL DEVELOPMENTS LLC 1 I �' G �, CO PC 11705 DB 5373/203 ��� �G Oh \ RIM: 655.82 ZONED: R-40 LOT 22, PC 11705 p ' 1 TCEINV.•f644.6 (DB 7407165) / 20 OAK / -/ 7„OAK � ��� 6 OAK 645 '�� 12 "OAK 6 'OAK 1 - - , - - _ 46 / / - - _4 'OAK / �� 65�1\�O 20'%14 "OAK / ANGLE IRON / 7�� 652 --� �! Jai / FOUND 6� 7 OAK (FOUND) N. C. S. P. C. \ REBAR / / - - - -653 - 14 '0A K 65� N: 456, 771.76 r - - 648 - / - _ ,( / E.• 1, 469, 400.30 10 'OAK / 12'%10 "OAK,(FOUND) 652/ S18°1 D 06 W 290.74 - - _8 "OAK- - - - - - 654 8 /O'OAK LE CF_0.99985572 _ 649 _(73.36)' a 14 OAK- - - 5 / 12' OAK 5��.8 OAK � �0'BUFFER 655 8 OAK / 6SO o r� o o co-2A . .65 . . . _. _ - _ .- . 6s6 . D _7or . - \ / .......... ..... ..:... ........... .�. .......................... 657- -NOW OR FORMERLY / 25 REAR YARD ........ z / RICHMOND HILL DEVELOPMENTS LLC 65 y. ....663- 663.....:?n. S v DB 5373/203 rn/ �.................... .... / 6' .............. . . .- .-.... ........ DA-7 DB. 74Q7 .. 5 N -658 / die / - . -_:. LOT 21, PC 1 705 . . . . 65 . . . . . . . . . . \ .... 0.09 AC ............ . ........... .......... .. c �� _6 OAK- . / . / ............ .................. -. C= 0.95 ..... TCE QTI cn 44 - 653 - I 6'6, i - - . . . . . . 7 o ; OAK �10_OAK�`074"OAK 8„O -654_ i Adk 6 OAK Ali w � 6s 12"OAK _ - 656- DA-B1 18"PINE 661- 0.12 AC //I\\ 9 _ n -657 U I / / C= 0.95 10 -tom -_i�K � o - s6 / \ / B-3 6 "OAK DA-3 0 1 0.42 AC - - - DA-4'/ -661 z o � - 663 - - \,65� / C=0.82 0.05AC�' I�--- m nNo \co 14 'OA / `�� C'f - _ 1232/89 10PlN�cG66m12" EDAR- - ��a\cn III\ a� �/ 6� 514 02'34"W 138.11 CID,W L u - .. . R.. 10' OAK LINE PER PC V705 () O m / U ....... 12 "OAK �.. REBAR MAPLE` 0.12 AC - - � � .. �---6............�Ix.r..........._........ (FOUND) i corO - - Om I '. 32 14 "Pll� ^ ? - C= 0.95 6 »E 138.12 Ss4' ...... N 10 24 00 0 ] \ �O`l'/ I REBAR LINE PER DB I FUTURE 25' I ... I (FOUND) APPARENT GAP 67171554 i M FRONT YA _ �.. - - 616 (0. 015 AC.) o < -7 63 1 1 00 Ise) co W C)�. / 6- DA-5 ` 1 c9 cD O N0.03 I o I 0.03AC / (0),���� WELL Ln D C= 0.50 . . . . . .663 . . . . . . . . . . . . . �. HOUSE -NOW OR FORMERLY � N I �660 660 DA-8 / OAK /W 66A- 0.07 AC R/W R! C_= 0.30 / - - 8„OA 8„ AK - ro 62- /663 664-- TELE \ - - 669 "CED R iPE - i(FOUND) 667 663 0 co _ - - - - GAS DA-9 GA - 0.15AC _ --- - C= 0.63 - / n- FOB- T T - - T L D - L OE L 7 7 7 II OE io -664 _ c�`� . / ............. z FANNY CORER MARTINEZ z of-6-662 F R DA-6 DB 67171554 FUTU / 662 0.18 AC WPP BENCHMA F 65 AN R/W R/W 663 IVA it IN R/W - C= 0.63 DAM / \664 7.85 / 661 � PIPE � / 6 665 / PAR TALL Y � I 6654 6' -GAS- - T T - T OE / V / � _ UND BURIED FOB / OE �- �E S17 46� W 136.91 (�E) R E ---- (FOL GAS S S GAS .16 A GAS _ - -GAS-- CA - � - -GAS - - - - __-=0.16AC-665 SAS - � CAS � - - / C= 0.56 O N17 46'08"E 356.90 ' -IF PROVIDENCE ROAD S (60' R.O.W.) \ \ MINOR ARTERIA CP I W- - W T T- fT W W � W W �_ - T W T T - - - _ ---- -- T T CONCRETE T T T T /-- - -TECH - _0211€WA -_--_-_-_�_ - --- PP OE 1 / OE OE- OE OE 8�- SIGN LEGEND PROPOSED \� 850 CONTOUR WITH ELEVATION CONCRETE CURB & GUTTER PROPERTY LINE El CATCH BASIN / CURB INLET STORM DRAIN AND ENDWALL BASIN DRAINAGE AREA BOUNDARY INLET DRAINAGE AREA BOUNDARY Lom C; arouP ENGINEERS PLANNERS SURVEYORS SCIENTISTS CES Group Engineers, LLP NC FIRM LICENSE #F-1240 274 N. Hwy. 16, SUITE 300 DENVER, NC 28037 T 704. 489.1500 www.ces-group.net SEAL: 0 ° ess/o _ ° ° 041342 °°o°°°pO it SUBMITTALS DATE: PURPOSE: 10/22/19 FIRST COUNTY SUBMITTAL W UM ZV_ W °O U Z W3: Ill LLI Z 0 J CO z O � `� W 0 Z O Z o v u) w 2 w z (.D co LU - U co O U z Z Q W0 0 LID WCNI � PROJECT NO: 7292 - 0819 DRAWING REVISIONS NO: REVISION DESC. DATE: DRAWN BY: SC REVISED BY: - CHECKED BY: TC ISSUED BY: SC DRAWING TITLE: DRAINAGE AREAS DRAWING NUMBER: ,opyright 2019 CES Group Engineers, LLP FRAME GRATE AND H00D GENERAL NOTES: BACK OF CURB SEE STD.NO. 840.03 USE CLASS "B" CONCRETE THROUGHOUT. Z } ~ X PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" Q ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. Q F_ , TOP ELEVATION OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT rZ-i� U Y �" �' Y o 12" CENTERS AS DIRECTED BY THE ENGINEER. LL J r Z O O _ o' L - - USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. .. A [C _ IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB z.. W Q LL = 00 io a:. ;o AS SHOWN ON STD. N0. 840.00. U O Ur .o '.. 6" '.o B.'. 6" USE TYPE "E", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. - - - - F ~ = Z W o. 'o FOR 8'-0" IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER ° D CO ~ LL O J W H Q 8'-0' TO 16'-0" IN HEIGHT USE 8" WALLS AND BOTTOM SLAB. ADJUST �,' :°''°''�� •o QUANTITIES ACCORDINGLY. O O (n= CONSTRUCT WITH PIPE CROWNS MATCHING. PLAN ° z Op t- H X g" SEE NOTE CHAMFER ALL EXPOSED CORNERS 1". r W t] SECTION X-X DRAWING NOT TO SCALE. r CD TOP ELEVATION TOP ELEVATION SEE STD. NO. 840.03 STEPS - STD. N0. 840.66 STEPS - STD. NO. 840.66 6 ° A �- 6 - - - - - - - TOP ELEVATION - - - - - D:: Cr 0 T A LL v.E-�i '1 ° �° z Qw PD. = 6" D G ,. 6" H m O_ _ SECTION Y-Y s" a" c s" < _ D vD '.. D .: O 0 °•.' •o° RISER HT.LO VARIES c 1 ' ` o .' O E Q a. . o o. .o, R Q �.i 0 6" SECTION J-J ' A 4 Q W WHERE 30" TO 36" PIPE IS USED a SEE NOTE SECTION M-IM N WHERE 42" TO 54" PIPE IS USED WHERE 30" TO 36" PIPE IS USED >- Q 0 - RISER HT. � Z VARIES. O o J J o ci o:r- of B - - -'. 6 D..' '0.1 A A j p. r..tr....a...�. :°1 a I 0 Iy WHERE 42" TO 54" PIPE IS USED -V. DETAIL SHOWING METHOD OF RISER CONSTRUCTION PLAN PLAN SHEET 1 OF 2 840.02 z 00 43" NOTE: USE TYPE "E", "F" AND "G" GRATE =a - UNLESS OTHERWISE NOTED. oN P\ 3" P H } Q Q z = U "'(D wJaHz B T 1111 000= 21/8 rr 21/8rr WQQILL = F­-U CDr0 ___ N N LLJ v~i�LL o O SECTION - LL SECTION - MM 0 0 - O < ID Cl) A oo A ALIGN FRAME WITH INSIDE 13/8" EDGE OF WALL TO ALLOW �"{ FOR VERTICAL ADJUSTMENT o. cod z OD 1- , ,- LU p r w r O O WALL SECTION I SECTION - BB B SECTION - PP SECTION - NN PLAN =m 4L. _� FRAME,GRATE, & HOOD ASS'Y J N 3/ [_ NI LI�Lo-� + 6" 2' Orr 6rr LI�Lo z CC 0 00 tom C4 = = - 3'- 0" `co `co a 1 4 r o> z p U Q Z Q Q 0) v �� - N a 13/q n _ K -K _ U 0 n O L M °' MyQ W SECTION - AA z < L M col 7�rr CID O cn aJ FRAME PLAN N SECTION - JJ >- -+ O W .g//� 3'-0%8r 55grr 1�6'� I� I R 3 R �211 - - - - Q 7 - -if- 7 I 4 > 6rr 2r_Orr 6rr 1/2r� 6rr 6rr 12/4/ 3/rr r 12rr r r 3/2rr 3v2rr r 0 FE CO o OQC z _LL O LL 3r Orr r /2rr r 3/„ 0�3/rr SECTION - KK 2' _ 111/2 rr 45/8rr HOOD ELEVATION SECTION - RR 840.03 IS06ur Protection as Required Use Rip Rap or Concrete Slab in Outlet Area Typical Pipe Outlet Detail L S EXPANSION JOINTS g" E-j 4, 6" I, #4 BARS "V" 6 8 STD. 840.03 FRAME, @ EQUAL SPACESBRAT ,v2rr .I ,err 3 rr R y R co 7 U 7 U I- 6' 0" a a PLAN coN nw JJ m Q w CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES m< d o # w TOP w � ai., USE ON FLAT ELEV. EXPANSION JOINT GRADES 2% AND UNDER 11 s, 3 0 DEPRESSED GUTTER LINE EXPANSION JOINT Ir--I---�--•1 PLAN OF TOP SLAB SECTION S-S ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE 6jBAR�SV #8 "W" BARS 44 BAR EXPANSION JOINT s TOP #4 BAR "V" a USE ON GRADES OVER 2% ELEV. @ EQUAL SPACES - - 'Or DEPRESSED GUTTER LINE EXPANSION JOINT 6' 0" I �1r 0„ IMI MAX. j 11/2„ DOWEL ELEVATION SECTION R-R NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN(BASED ON MIN. HEIGHT, H, WITH NO RISER) DIMENSIONS OF BOX AND PIPE COVER DIMENSION CU.YDS. GONG. IN BOX DEDUCTIONS ONE PIPE PIPE SPAN WIDTH WIDTH SPAN MIN. HEIGHT BARS-U BARS-V BARS-W TOTAL TOP SLAB BOTTOM SLAB TOT. CONC. FOR MINIMUM HEIGHT. D A B C G H E F NO. LENGTH NO. LENGTH NO. LENGTH LBS. 12" 3'-0" 2'-2" -- -- 2'-9" -- -- -- -- -- -- -- -- -- -- 0.235 0.772 0.015 0.026 15" 3'-0" 2'-2" 3'-0" 0.235 0.829 0.023 0.036 18" 3'-0" 2'-2" 3'-3" 0.235 0.887 0.033 0.049 24" 3'-0" 2'-2" 3'-9" 0.235 1.001 0.059 0.085 30" 3'-0" 2'-2" 3'-4" 4'-3" V-2" 4' 0" 4 1'-5" 2 3'-9" 3 3'-9" 39 0.123 0.321 1.433 0.092 0.127 36" 3'-0" 2'-2" 3'-10" 4'-9" 1'-8" 4'-0" 4 1'-11" 3 3'-9" 3 3'-9" 43 0.161 0.358 1.714 0.132 0.178 42" 3'-0" 2'-2" 4'-5" 5'-3" 1'-5" 3'-2" 4 1'-8" 2 2'-11" 3 2'-11" 32 0.112 0.318 1.738 0.180 0.243 48" 3'-0" 2'-2" 5'-0" 5'-9" 2' 0" 3'-2" 4 2'-3" 3 2'-11" 3 2'-11" 35 0.145 0.352 2.052 0.235 0.317 54" 3'-0" 2'- 2 1 5'-7" 6'-3" 2'-7" 3'-2" 4 2'-10" 5 2'-11" 3 12'-11"1 41 1 0.180 10.386 1 2.387 0,297 0.401 * RISER HAS .228 CUBIC YARDS OF CONCRETE PER FOOT HEIGHT Z O F- } Q Q rZ=co LL _j O0Cj)=z W Q Z LL = aUM 0 =~zw (/D�wOJ CC ID O Q Z H = 1 0-, W 0 _ O Z LL 1-4 O C7 H Q W CO 0- < = O � v= �L Ln V z = Q W H C()W_ } = N ��- z 0 O 0 V O Cc 840.02 z 00 DETAIL SHOWING TYPES OF GRATES USE ACCORDING TO WATER FLOW. 23/ " 2 113i4 1 /2 < Q z o = U B (3 , LL J r TYPE "G" TYPE "E" TYPE "F" A A 1 "T " ooco=z U < LL O 0s c0\ 0 W -� WATER FLOW SAG `- WATER FLOW �-MUMMI., I 9%g" I CO LL~ rr OH Q o HCZ I- �� --------------------------- - - - - -- B 1/2„� 13/ w r o SECTION B-B --------------------------------- 13, 21/„ I� H -WATER FLOW SAG WATER FLOW Q LL O DO SECTION A -A GO 2 TYPE "F" TYPE "E" TYPE "G" TYPE - E z = 3:z Q Q U Q 9 P RAISED FLOW ARROW 4„ 1 23/ /s HIGH .� 0 o RAISED FLOW ARROW 23/4 HIGH '1 � D � � N Q Q W o ::�\ \ 1 /2CID aQ~ ~ C3 �T m _ CID z m\ /8„ O a O /6 \ < LU o LJ QQ= P 1 /2 " N \ 1 rI 1/8rr 1 /2r 13/4' Fes- 2'-113/4" 1 /2 " R /8rr 2'-113//4 LL_ M LL 0 LL-^ /2''l -� �1�2 r, 13/4 SECTION A-A� 1 /2 I /8 ►I SECTION A -A TYPE G SHEET 2 OF 2 840.03 8" Min. Low Permeable Soil Ll °o Control Joint Cut Geogrid Storm Drain Pipe For pipes larger than 24", a concrete collar may be cast around pipe for ease of construction and appearance. CReinforced Soil 1' Min. Thickness Concrete Collar if Applicable Keystone Cap Unit Keys dard now Unit r Concrete Collar if Applicable Scour Protection as Required Z C 0) 0 Unreinforced Concrete or Crushed Stone Leveling Pad Typical Pipe Outlet Section Standard Unit - Near Vertical Setback is Y PLAN WITH GRATE & FRAME REMOVED SECTION X-X J ,urr.rvulr.rv�iu� )P ELEVATION 840.16 FRAN RATE (SEE NOTE) GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 78M STONE IN A POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER CHAMFER ALL EXPOSED CORNERS 1" DRAWING NOT TO SCALE. MAX. PIPE THIS SIDE - 18" m SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONC. IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN I WIDTH MIN. HEIGHT D A B H BOTTOM SLAB WALL PER FT. HT. TOTAL CONCNETE i0R MINIMUM HEIGHT, H C.M. R.C. 12" 3'-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.015 0.026 15" 2'-3" 0.648 0.023 0.036 18" 2'-6" 0.703 0.033 0.049 24" 3'-0" 0.814 0.059 1 0.085 30" 3'-0" 2'-0" 3'-6" 0.222 0.222 0.925 0.092 0.127 1" DEPRESSION 1 r-7!/$n 1 r 77 CV N SECTION G-G 2'-31/4r' 4 � 1%6" �2" SECTION H-H 8" Min. Low Permeable Soil III11 Grid Depth IIIIII jIII Reinforced Soil Redirect Grid Around Pipe �I as Required IIII Approximate 'III Limits of III Excavation Retained Soil II �I o0�0.a _ a V <<4 4" Perforated PVC -III IIIIIIIIIIII11I11111II1I11I1 �1 /2rr t 1 %2 " '\ 15/8 r 15/8 rr T - o �� _G o G 1* 0 11 0_ o J OEEEB HN "\ 1'-4%2" V-75/8" 1'-7!J'8rr PLAN OF GRATING CAST IRON #4 BAR 6" DOWEL 3'-6" F E E N �- - ----- -- --� F PLAN OF FRAME CAST IRON 1/8rr /8rr 1/8rr 1/8rr 1 rr 3 33/ 1 rr 1 rr 2 33/ 1 rr 1/8rr 1/8rr /8rr 1/8 rr 3/ n 3/ n I 3/ " 3/ " 3'-2" 2 2 VIA VIA 2/ " �� 21/ rr 8 _ 8 _ 3'-13/4" N N 2r-13/rr N N 3'-6" 2'-6r' SECTION E-E SECTION F-F Keystone Cap Unit Keystone Standard Unit Unit Drainage Fill (3/4„Crushed Rock or Stone) c i� .a) 0 Finished Grade Drainage Tile =1 I I11 When Site Conditions =Wir, � 117�1r= U Require nreinforced Concrete Foundation Soil or Crushed Stone g Levelin Pad Typical Wall Section with Pipe in Reinforced Zone Standard Unit - Near Vertical Setback Z O On } aQ CD -1 LL -1 0 Z OC15O = wazw= F 0 00-i =~zw (/D�w0J wo O cn Q JI Lu H -I W � t] o LL W cs J H Z w Q N � < oa 00 O C0 = Q Q � z W = Q H cn W _ >-W N z T � O O Ci _ 840.14 z 00 �} aQ rZ C, LLJ,_"2! 0 CD M WazW= a"=o� r-x~zw co [ LL 0 J o C) < z �� 1 LUH w0 0 r N 't W 00 F- o OQG Q O (D d � O r Q Z O = Q v 00 W 0 O Q Q CD LL z Q W < Z = 0 H H H oat w W =)C fr 0 U_ 840.16 IMI � srawP C; ENGINEERS PLANNERS SURVEYORS SCIENTISTS CES Group Engineers, LLP NC FIRM LICENSE #F-1240 274 N. Hwy. 16, SUITE 300 DENVER, NC 28037 T 704. 489.1500 www.ces-group.net SEAL: \ \11111111111I//�/ N CARo 000 oo�FE83 _ 0 0 041342 Ick N cc'�a/NEAP �: , !/VO000O000 Olr.`. SUBMITTALS DATE: PURPOSE: 10/22/19 FIRST COUNTY SUBMITTAL W UM Z� WC)O _N Z W� 0. W W Z 0 J CO z O W W -Oz w 0 0_j0 W o �n v W = _jNQ (D2LU LL c�o� W 0 - Z U co U z 0. 0 O w 0 w LO PROJECT NO: 7292 - 0819 DRAWING REVISIONS NO: REVISION DESC. DATE: DRAWN BY: SC REVISED BY: CHECKED BY: TC ISSUED BY: SC DRAWING TITLE: DRAINAGE DETAILS DRAWING NUMBER: C1 2mO Copyright 2019 CES Group Engineers, LLP � rarauP La = THE LENGTH OF THE RIPRAP APRON. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" STIR # dQ d50 dmOx THICKNESS Lo 3d0 OUTLET WIDTH HW-1 18" 0. 5' 0.75' 1.125' 10' 4.5' 11.5' USE THIS FOR UPSTREAM FILL RIPRAP BETWEEN PIPES NOTES: 1. INSTALL A GRADED GRAVEL LAYER OR A SYNTHETIC FILTER CLOTH BETWEEN THE RIPRAP & SOIL FOUNDATION. 2. ENSURE THAT RIPRAP CONSISTS OF A WELL -GRADED MIXTURE OF STONE, LARGER STONE SHOULD PREDOMINATE, WITH SUFFICIENT SMALLER SIZES TO FILL THE VOIDS BETWEEN THE STONES. THE DIAMETER OD THE LARGEST STONE SHOULD BE NO GREATER THAN 1.5 TIMES THE d50SIZE. 3. SELECT STONE FOR RIPRAP FROM FIELD STONE OR QUARRY STONE. THE STONE SHOULD BE HARD, ANGULAR, & HIGHLY WEATHER -RESISTANT. THE SPECIFIC GRAVITY OF THE INDIVIDUAL STONES SHOULD BE AT LEAST 2.5. 4. ENSURE THAT THE SUBGRADE FOR THE FILTER AND RIPRAP FOLLOWS THE REQUIRED LINES AND GRADES SHOWN IN THE PLAN. COMPACT FILL REQUIURED IN THE SUBGRADE TO THE DENSITY OF THE SURROUNDING UNDISTURBED MATERAIL. LOW AREAS IN THE SUBGRADE ON UNDISTURBED SOIL MAY ALSO BE FILLED BY INCREASING THE RIPRAP THICKNESS. 5. FILTER CLOTH, MUST MEET DESIGN REQUIREMENTS AND BE PROPERLY PROTECTED FROM PUNCHING OR TEARING DURING INSTALLATION. REPAIR ANY DAMAGE BY REMOVING THE RIPRAP AND PLACING ANOTHER PIECE OF FILTER CLOTH OVER THE DAMAGED AREA. ALL CONNECTING JOINTS SHOULD OVERLAP SO THE TOP LAYER IS ABOVE THE DOWNSTREAM LAYER A MINIMUM OF 1 FOOT. IF THE DAMAGE IS EXTENSIVE, REPLACE THE ENTIRE FILTER CLOTH. 6. CONSTRUCT THE APRON ON ZERO GRADE WITH NO OVERFILL AT THE END. MAKE THE TOP OF THE RIPRAP AT THE DOWNSTREAM END LEVEL WITH THE RECEIVING AREA OR SLIGHTLY BELOW IT. 7. ENSURE THAT THE APRON IS PROPERLY ALIGNED WITH THE RECEIVING STREAM AND PREFERABLY STRAIGHT THROUGHOUT ITS LENGTH. IF A CURVE IS NEEDED TO FIT SITE CONDITIONS, PLACE IT IN THE UPPER SECTION OF THE APRON. 8. IMMEDIATELY AFTER CONSTRUCTION, STABILIZE DISTURBED AREAS WITH VEGETATION. 9. INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS. CES GROUP RIPRAP OUTLET PROTECTION STD. N0. ENGINEERS, LLP (FLAT AREA NO WELL-DEFINED CHANNEL 6.41C URFACE PER SITE PLAN LQ PEA GRAVEL WRAPPED IN SOIL FILTER FABRIC 21 8" PERFORATED UNDERDRAIN PLAYGROUND UNDERDRAIN DETAIL NOT TO SCALE REVISIONS MODULE NOTES REVISION DATE 1 REV BY DESCRIPTION OF REVISION TYPE QUANTITY HEIGHT 1 10WN9 JS ADDED PIPE INVERT ELEVATIONS. B 2 f0I019 JSA ADDED TYPICAL ELEVATION VIEW. 61' 1 E C1" 1 a' F 1 1 S' Ot 1 fi' sr 1 s• TOTAL B VOLUME2.833 ICUBICFEET 06" PERFORATED PVC UNDERDRAJN LEGEND: PRETREATMENT MODULES IINDICATES As = 315 SF OUTLET CONTROL WEIR. SAND FILTER MODULES SUPPLED BY OLDCASTLE INFRASTRUCTURE. STORMCAPTURE MODULES BY OLDCASTLE INFRASTRUCTURE. INSIDE DIMENSIONS: 7' W x 15' L z 6' H, SYSTEM INVERT: 651.00'. IINDICATES Af = 290 SF INSTALLED h GROUTED IN PLACE BY OTHERS. ----------, - - - - - - - --------I ---------- - - MODULE DESIGNATION NON-STANDARD \ r---I .. r I I I .• - rINDICATES `yj'1 MODULE U1E WALL OPENIINC5, C 1WE 41000LE DETAILS •` I . u--_- - . - - - - - - - .r------ T -1--- -- =- - - - - - - - ��- - - r- ,r -- - - -L - - - �' 08" HOPE, c INLET INVERT: 656,00'. e19- RCP, OUTLET INVERT: 651.00'. I I. �. I l 4. I a 7 L -LI- J L - - - _ J L - J I I I I I l - - -- -`J 1 I L- - - lI -" fib' HDPE, INSET INVERT. 656.00. 'r 024' MANWAY ACCESS WITH DRILLED IN STEPS 1 015' RCP, (TYPICAL 4 PLACES) I 015' RCP, INLET INVERT: 65100'. INLET INVERT: 655.D0'. DESIGN NOTES: I. DES IGNLOADINGS: A AASHTO HS-20-44 Wf IMPACT- B. DEPTH OF COVER = B" - 5'-0" (120 PCF ASSUMED)- 48'-U1r2" (INCLUDES h' GAP PER SECTION) - PRELIMINARY - C. ASSUMED WATER TABLE = BELOW BOTTOM OF PRECAST. D. DRY LATERAL EARTH PRESSURE (EFP) = 45 PCF, NOT FOR CONSTRUCTION E. LATERAL LIVE LOAD SURCHARGE = 8D PSF (APPLIED TO8' BELOW GRADE). F. NO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALL PIERS, OR FOUNDATIONS. PLAN VIEW 2, CONCRETE 28 DAY COMPRESSIVE STRENGTH SHALL BE 6,000 PSI, SCALE:: 3116" = 1' � Qldcastle lnfrastructur4' 3. STEEL REINFORCEMENT: REBAR, ASTM A-615 OR A-706, GRADE 60. 4. MESH REINFORCEMENT: ASTM A-1064, 51.2. GRADE 80. Aem COMPANY n n n ^`I nr ,,r� n[m� n SPEC CEMEN 1: ASTM M C-1 SO uSPECIIvFICATION. Ph 9gp.5798Bt9 RWasN�Imnway..mm THIS M]CUNENT IS THE PROPERTY OF OLCCASTLE INFRASTRUCTURE, INC- c5. . STORML+AP I LIRE MODULE TYPE = DETENTIONIS+AND FILTER. r �-i�� '` NOTES TO REVIEWING ENGINEER: IT IS CONFIDENTIAL, SUR M ITTEO FOR REFERENCE PURP0. ES ONLY AND SHALL NOT BE USED IN ANY WAY ?NJ U RI OILS TO THE INTERESTS OF- OR 7. REQUIRED BASE LAYER DEPTH = NOT APPLICABLE. 1. THIS SYSTEM IS DESIGNED TO THE PARAMETERS NOTED. PLEASE VERIFY THAT THESE PARAMETERS MEET PROJECT VNTHOUT THE WRITTEN PERMISSION OF OLDCASTLE INFRASTRUCTURE- INL COPYMGHR®]019 OLDCASTLE INFRASTAUCTURE, INC RIGHTS RESERVED- 8. REQUIRED NATIVE ALLOWABLE SOIL BEARING PRESSURE = 2,5DO PSF. NATIVE SOIL SHOULD BE REQUIREMENTS (I.E. LIVE LOAD AND FILL RANGE). IF DESIGN PARAMETERS ARE INCORRECT NOTIFY OLDCASTLE IMMEDIATELY FOR STORMCAPTURE � LEVELISCREEDED AND COMPACTED ADEQUATELY TO ALLOW FOR REQUIRED BEARING REDESIGN AND RE -PRICING. CAPACITY- 2. REVIEWING ENGINEER TO CONFIRM ALL PIPE PENETRATION LOCATIONS, SIZES, AND INVERTS- $C2 Det@nti0nlSdnd Fill@r 5 @m SyStem REFERENCE STANDARDS: 3. REVIEWING ENGINEER TO CONFIRM ALL MANWAY ACCESS LOCATIONS AND RIM ELEVATIONS. c�em De A. ASTM C 890 4. UNLESS OTHERWISE NOTED, ALL PIPE SUPPLIED AND INSTALLED BY OTHERS, CES B. ASTM C 891 5. THIS SYSTEM IS DESIGNED FOR A GROUNDWATER TABLE BELOW SYSTEM INVERT- REVIEWING ENGINEER TO VERIFY THAT THE Joe fame The Learning Experience Waxnaw, INC C. ASTM C 913 DESIGN GROUNDWATER TABLE IS BELOW INVERT OF PRECAST. IF DESIGN PARAMETERS ARE INCORRECT NOTIFY OLDCASTLE 3 ENJcN�EER CH W SA R 90 10. CONSTRUCTION EQUIPMENT EXCEEDING DESIGN LOADING SHALL NOT BE ALLOWED ON IMMEDIATELY FOR REDESIGN AND REVISED PRICING, NINiq STRUCTURE. ANY DESIGN CONSTRAINT DIFFERENT FROM ABOVE REQUIRES CUSTOM B. THIS SYSTEM IS DESIGNED WITHOUT A CONTAINMENT MEMBRANE LINER- IF A LINER IS NEEDED PLEASE CONTACT OLDCASTLE TO STRUCTURAL DESIGN AND MAY REQUIRE THICKER SUBGRADE AND REVISED PRICING. PROVIDE THIS OPTION IN THE FINAL DESIGN. De°entiort SCDD-1459-2-SC2- SFDT p) WDATE 1 OF 2 InnlvalnR 101ta19 rel 0 b M m 659.70 - LOWEST PROPOSED GRADE ABOVE SAND FILTER 71 a a s 4 4 4 4 a a s a 4 4 a 4 a Q a TOP OF CONCRETE WEIR 4 ELEV = 656.10 a 4 a 4 4 4 4 a a 6" PERFORATED SCHEDULE 40 PVC UNDERDRAIN PIPE a 4 ROWS OF 3/8" PERFORATIONS PER ROW a 4 ROWS PER FOOT. 4 4 4 a al a 4 4 4 4 4 4 Q 4 a a a SAND FILTER SECTION NOT TO SCALE 657.58 657.00 656.10 - TOP OF WQv STORAGE CLEAN WASHED "CONCRETE" SAND FILTER LAYER 652.50 651.00 650.42 024" HS-20 RATE) U&NWAY ACCESS WITH DRILLED IN COMPACTED FILL. SEE INSTALLATION GUIDE, PArING/OVERBURDEN, BY CONTRACTOR, STEPS AND RISERS/GRADE RINGS AS REQUIRED TO GRADE. BY OTHERS. SEE DESIGN NOTE 10. STORMCAPTURE MODULES BY OLDCASTLE INFRASTRUCTURE. 01" VENT HOLE ONE SIDE ONLY. RIM' fi8b52.56' iAA7(IMUM 8.08 �IiNfMU#� 5' LtAx COVER 6' WIN COVER ! I EL: 657,58' EL 657.00' III 1 I II -Ili -I -EL:656.10' `III -I -! f II e 1111 I I 111=11! - - - - - - - - - - - - - - - - - - - - - - - -- I I a 652.50' 111 FL 651.00' 4 :��` 7' - 4 EL: 650. 2' WRAP GEOTExTILE FABRIC fib' UNDERDRAIN ErY STEPS INSIDE VAULT INSTALLED BY OLDCASTLE 04' TERMADUCT, TYPICAL. 1' MINIMUM UP SIDES OTHERS OF SYSTEM. I$' SAND MEDIA BY OTHERS CEOTExTlLf FABRIC, NOTE: SEE INSTALLATION GUIDE. TERwDuCT INSERTS TO BE KNOCKED OUT AT CONTRACTOR TO ENSURE ADEQUATE BEARING SURFACE SPECIFIED LOCATIONS ONLY (BY OTHERS), PROVIDED IN ACCORDANCE WITH PROJECT SPECIFICATIONS. SEE DESIGN NOTES 7 & 8. TYPICAL ELEVATION if- PERMANENT POOL DEPTH SCALE: aW = 1'-a• - PRELIMINARY - NOT FOR CONSTRUCTION Okkwm tle Infrastructure A CfR G°MTLNY Ph : eaD.sia.71 doraeueazamrre�el com THIS DOGLmENT 1S THE PROPERTY OF OL D CAST LE INPRAS T RUCTURE, INC. IT IS CDNFID-TIAL, E -I TVEO POR R ENCE POR POSES ONLY "I$HAL; NOT BE USED IN ANYwar IN' s TO THE INTE RESrs OP, QR W ITH W T THE WRITTEN PERM155ION OF OLOCASTLE INFRASTR UCTURE. INC. COMMITm W18 OL K-57LE INFRASTRUOTURE. INC ALL Qq TR RESERVED. STORMCAPTURE SC2 Detention/Sand Filter System pTslomar; CES NOTES; lnh Nerve: The L.eaming Experience - Waxhaw, NC 7. ALL SAND FILTER YEDLA, DRAIN ROCK PROVIDED BY CONTRACTOR- AGGREGATE, PIPE AND FITDNGS, DATE SALES orwwx EHCaNEER CHEp1ED &4E100111 2. TERMADUCT INSERTS TO BE KNOCKED OUT AT SPECIFIED LOCATIONS RS 19 ` N V H ONLY (BY OTHERS). SCDD-1459-2-SC2 SFDT CdVDATE 2 OFx I.. _..., - 1LUf0119 ENGINEERS PLANNERS SURVEYORS SCIENTISTS CES Group Engineers, LLP NC FIRM LICENSE #F-1240 274 N. Hwy. 16, SUITE 300 DENVER, NC 28037 T 704. 489.1500 www.ces-group.net SEAL: Iiil li�nllA� ,`"\A CAROB''% O �FSSS/ ° O �041342 I n-22- Ig 00000000° Olr. 44. C IS SUBMITTALS DATE: PURPOSE: 10/22/19 FIRST COUNTY SUBMITTAL w UM zv- W00 N U z LLI 0. _ W w Z 0 � J DO z O 0 Z O Z � W > w 0 cn W w �n � w = J 0 2 o `J Q Z (D DO O w 0 -U DO U z Q W 0 I.J_ W LO 04 PROJECT NO: 7292 - 0819 DRAWING REVISIONS NO: REV/SIGN DESC. DATE: DRAWN BY: SC REVISED BY: CHECKED BY: TIC ISSUED BY: SC DRAWING TITLE: DRAINAGE DETAILS DRAWING NUMBER: C12.1 Copyright 2019 CES Group Engineers, LLP