Loading...
HomeMy WebLinkAboutSW3191103_Deed Restrictions_11/18/2019High Density Residential Subdivisions Deed Restrictions & Protective Covenances In accordance with Title 15 NCAC 2H.1000 and S.L. 2006-246, the Stormwater Management Regulations, deed restrictions and protective covenants are required for High Density Residential Subdivisions where lots will be subdivided and sold and runoff will be treated in an engineered stormwater control facility. Deed restrictions and protective covenants are necessary to ensure that the development maintains a "built -upon" area consistent with the design criteria used to size the stormwater control facility. 1, 1 bkAt_ , acknowledge, affirm and agree by my signature below, that I will caul a following deed restrictions and covenants to be recorded prior to the sale of any lot: The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number , as issued by the Division of Energy, Mineral and Land Resources under the Stormwater Management Regulations. 2. The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the stormwater management permit. 3. These covenants are to run with the land and be binding on all persons and parties claiming under them. 4. The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State of North Carolina, Division of Energy, Mineral and Land Resources. 5. Alteration of the drainage as shown on the approved plan may not take place without the concurrence of the Division of Energy, Mineral and Land Resources. 6. The maximum built -upon area per lot, in square feet, is as listed in the attached table. This allotted amount includes any built -upon area constructed within the lot property boundaries, and that portion of the right-of-way between the front lot line and the edge of the pavement. Built upon area includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, coquina and parking areas, but does not include raised, open wood decking, or the water surface of swimming pools. 7. Each lot will maintain a 30** foot wide vegetated buffer between all impervious areas and surface waters. **50 foot for projects located in the 20 coastal counties. 8. All runoff from the built -upon areas on the lot must drain into the permitted system. This may be accomplished through a variety of means including roof drain gutters which drain to the street grading the lot to drain toward the street or grading perimeter swales to collect the lot runoff and directing them into a component of the stonnwater collection system. Lots that will naturally drain into the system are not required to provide these additional measures. Form DRPC-3 Rev.2 05Nov2009 Page 1 of 2 High Density Residential Subdivisions Deed Restrictions & Protective Covenances Signature: Date: Il lg a Notary Public in the State of . Countyof f7 f1 lc� do hereby certify that �L( kjjD personally appeared before me this the 4-z day of A (JV 20 and acknowledge the a execution of the foregoing instrument. Witness my hand and official seal, SEAL Signature ' / RAENAE H, I ITTL� My Commission expires "f'- l ' ZZ NOTARY PUBLIC Stanly County North Carolina my Commission Expires April 16, 2022 Form DRPC-3 Rev.2 05Nov2009 Page 2 of 2 Lot Built Upon Area Allowance Lot Number Lot Size (sf) BUA Allowed (sf) Lot Number Lot Size (sf) BUA Allowed (sf) 1 4424 2759 51 3150 2449 2 3727 2778 52 3675 2454 3 3727 2778 53 3675 2454 4 3727 2778 54 3150 2449 5 3727 2778 55 3167 2426 6 4259 2783 56 3304 2465 7 4200 2759 57 4201 2651 8 3675 2754 58 4161 2635 9 3675 2754 59 3286 2446 10 3675 2754 60 3162 2460 11 3675 2754 61 3150 2449 12 4200 2759 62 3675 2454 13 4200 2759 63 4645 2837 14 3675 2754 64 3675 2754 15 3675 2754 65 3675 2754 16 3675 2754 66 3675 2754 17 3679 2754 67 3675 2754 18 4347 2754 68 4200 2759 19 4304 2673 69 4200 2759 20 3317 2469 70 3675 2754 21 3176 2435 71 3675 2754 22 3175 2457 72 3675 2754 23 3320 2522 73 3675 2754 24 4179 2576 74 4200 2759 25 3746 2470 75 3675 2454 26 3150 2451 76 3150 2449 27 3150 2451 77 3150 2449 28 3150 2451 78 3150 2449 29 3163 2451 79 3675 2454 30 3859 2507 80 3765 2511 31 4826 2937 81 3273 2511 32 3803 2751 82 3273 2511 33 3685 2758 83 3818 2511 34 3816 2789 84 4292 2810 35 4861 2946 85 3789 2806 36 4217 2759 86 3789 2806 37 3675 2754 87 3789 2806 38 3675 2754 88 4330 2811 39 3675 2754 89 3789 2506 40 4200 2759 90 3248 2502 41 3675 2454 91 3248 2502 42 3150 2449 92 3248 2502 43 3150 2449 93 3746 2504 44 3150 2454 94 3675 2454 45 3176 2454 95 3150 2449 46 3916 2527 96 3150 2449 47 3685 2453 97 3150 2449 48 3150 2449 98 3150 2449 49 3150 2449 99 3675 2454 50 3150 2449 Total BUA Allowed = 258674 *BUA allowed includes all impervious within lot property lines. This includes the townhome unit, walkways, portion of driveway, and portion of sidewalk that falls within the lot boundary. This also includes a 100 square foot allowance per lot for future patios and a 215 square foot miscellaneous allowance