Loading...
HomeMy WebLinkAboutSWG040115_Apprentice Academy Combined Sewer Extension Plans_10/29/2019A91f SEEM SICNES WAW1,L VAVft WARREN NIIUX PARS 4 N7LNINLHAM GMNf PIRGOX NAIIAI EEARORC y� O wnmucA mlNls � 9,��, ��s raDAin Nlemx cmlfwo auMwNx DNancE MPCII[II AYERY ERANNIM NIRIM 'AXC11 "0"' GIBNAN NASN AIlIAX[IN IIIDIU DNN � EOftLONBE MAOIGON MANOR WASWN;IGN IVRPf It DARE RHAXE OAWCIW AANDUIPH WAKE NUNCOMBE WCOWILL CAIAWBA ROWAN CHATHAM ILSON %N swAlx NU NarwnaR IOINston Xuuflxl PROFESSIONALInD,,,,� IIRPEQlD IIXCOIN fANFPAUS Ill EfN[ GRAHAM WCXSOX NFNO(P.41N RARNEfI "NECA POIN —LN SEA" MORE CPAVIN RERONEE MA CDX fAANSYLYANIa CIEY[EAND MFCAIFNBUAG MIXIICAM[RY MM11R '' CLAY L1IAIIRUXD SAMPSONM � PAMLICU ��, NN N ANXIM RCHMp10 NCI7 OLIPLIP IUMES w scleunD `lFOR THE SANITARY SEWER EXTENSION RORESOX NUDEN MEOW CaRQR[t o PENNER f� MUMRUS "Na Project Location VICINITY MAP NOT TO SCALE Airport I� N t 0 j.4v1ONROE 1 fNPop.37,280 ` a 207 Ad 200 ; �ousto \ ^' SITE LOCATION 1" = 2 MILES Know what's below. Call before you dig. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. SC LAW REQUIRES THE CONTRACTOR TO CALL THE UTILITY PROTECTION CENTER AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE RELOCATION OF ALL THE UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. Utility Contacts Contacts Water, Wastewater Utility Provider: Contact: Mr. Rich Riser City of Monroe Water and Sewer Telephone: (704) 282-4646 Email: rriser@monroeinc.org Surveyor Information: Griffin Surveying Services, PA Contact: David E. Griffin Address: 1310 Brief Road East, Monroe, NC 28110 Phone: (704) 753-5008 Fax: (704) 753-9041 Email: david@griffinsurveying.net TO SERVE THE APPRENTICE ACADEMY HIGH SCHOOL IN UNION COUNTY, NORTH CAROLINA SHEET INDEX SHEET: SHEET NO COVER SHEET EXISTING CONDITIONS PLAN (STA. 0+00 TO STA. 21+50) SS1.0 EXISTING CONDITIONS PLAN (STA. 21+50 TO STA 45+47) SS1.1 CLEARING AND GRUBBING PLAN (STA. 0+00 TO STA. 21+50) SS2.0 CLEARING AND GRUBBING PLAN (STA. 21+50 TO STA 45+47) SS2.1 OVERALL SANITARY SEWER PLAN SS4.0 SANITARY SEWER PLAN AND PROFILE (STA. 0+00 TO STA. 10+00) SS4.1 SANITARY SEWER PLAN AND PROFILE (STA. 10+00 TO STA. 21+50) SS4.2 SANITARY SEWER PLAN AND PROFILE (STA. 21+50 TO STA. 35+00) SS4.3 SANITARY SEWER PLAN AND PROFILE (STA. 35+00 TO STA. 45+47) SS4.4 SANITARY SEWER DETAILS (SHEET 1 OF 3) SS6.0 SANITARY SEWER DETAILS (SHEET 2 OF 3) SS6.1 SANITARY SEWER DETAILS (SHEET 3 OF 3) SS6.2 Owner Information: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com ALL WORK SHALL CONFORM TO THE CURRENT CITY OF MONROE'S WATER RESOURCES DEPARTMENT STANDARD SPECIFICATIONS AND DETAILS. ANY DISCREPANCIES BETWEEN THE PLANS AND SPECIFICATIONS SHALL BE SUBJECT TO THE DECISION OF THE WATER RESOURCES ENGINEERING MANAGER OF THEIR AUTHORIZED REPRESENTATIVE. Project No. 18219-1090 IIIII DWG NO. 01,1307-D2 IIII LEGEND PL EXISTING PROPERTY LINE - EXISTING STREAM CENTERLINE 260 EXISTING CONTOUR MAJOR -\/1558,/\ BASE FLOOD ELEVATION EXISTING CONTOUR MINOR I I AREA OF FLOODWAY 16W EXISTING 16-INCH WATER MAIN 100-YEAR FLOODPLAIN EXISTING ASPHALT 500-YEAR FLOODPLAIN W W W EXISTING WETLAND AREA 500 YEAR FLOODPLAIN LIMITS 100 YEAR FLOODPLAIN LIMITS CAMP BRANCH CREEK BOTTOM OF CREEK: ± 571' MARTHA H LAI Q EXISTING ID 09-316-00: STREAM PL O PL-- SX SFO L------- ---- A� �s �O . _ 0000000 77 77 30' EXISTING � ,, '' � EASEMENT �7 1 ��� �y7 6'xOO���j zoo - 7 77 F sF � � F EXISTING SSMH 49A \� / 7 RIM: 582.19 � \ INV. IN:571.99 \ �0 / INV. OUT: 571.84 O 1 BEARSKIN CREEK BOTTOM OF CREEK: ± 572' EXISTING 6-INCH SANITARY SEWER LINE EXISTING SSMH 49 // 100 YEAR FLOODWAY LIMITS RIM: 580.95 1 APPROXIMATE LOCATION OF INV. IN: 572.05 / � INV. OUT: 571.85 / EXISTING WOOD LINE 00 1 / EXISTING CONDITIONS PLAN STA. 0+00 TO STA.10+00 0 m Q MARTHA H LAND I D 09-316-002 APPROXIMATE LOCATION OF EXISTING WOOD LINE I 9+00 J I EXISTING Q STREAM `/ \1 V! 1 11 Y V V/ V/ 1 II V I I I V/ 1 Y V 1 `/ A Y "zxIv i IIIv w, Ixi v v I v i I v I —" STA. 10+00 TO STA. 21 +50 WETLAND AREA, TYP. co OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. 1 ( IN FEET ) REVISION DATE o z� �� zQ Q o � w� a� of U. Ln m a) v LL— O = U ,C �V CER1 ���--n �P � P cU � � H � P L�P� � 4 u ( IN FEET ) 1 FILE NAME: SSI.O.dwg REFERENCE FILE: I82I9-I090 BASE.dwg PROJECT NO. I82I9-I090 "d� SHEET SS1v0 DWG NO.0191307-D23 LEGEND PL EXISTING PROPERTY LINE o EXISTING STREAM CENTERLINE 260 EXISTING CONTOUR MAJOR BASE FLOOD ELEVATION EXISTING CONTOUR MINOR AREA OF FLOODWAY 16W EXISTING 16-INCH WATER MAIN 100-YEAR FLOODPLAIN EXISTING ASPHALT 500-YEAR FLOODPLAIN EXISTING WETLAND AREA APPROXIMATE LOCATION OF EXISTING WOOD LINE 000 EXISTING JURISDICTIONAL WETLAND AREA, TYP. i\ 24+00 100-YEAR FLOODPLAIN LIMITS 25+0p MARTHA H LAND ID 09-316-002 MARTHA H LAND ID 09-316-002 26+0p J J a J a J a J a APPROXIMATE LOCATION OF EXISTING WOOD LINE ALEXANDER FRANK HOWARD ID 09-316-002E i EASEMENT � 30 SANITARY SEWER PROPOSES i 2g+00 WER LINE 2g+00 ENT OF SANITARY SE - PROPOSED p,LIGNM Y SEWER EASEMENT 27+00 PROPOSES 30' SANITAR 100-YEAR FLOODPLAIN LIMITS EXISTING CONDITIONS PLAN STA. 21 +50 TO STA.35+00 30+00 Qp 3 QQ EXISTING e� GARBAGE PILE e�- � r e r5 3 QO I OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com 0 <0G G` REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. 1 REVISION DATE o z� zQ Q o � w� a� H d Q O I� ago `QE \ J Io O and ( IN FEET ) � d C) x � Q z P� P � c PROPOSED MANHOLE Z STATION 45+30 0 RIM:634.18 � U u ld � H O U U w P� P� u O v = RONNIE SIMPSON Z PIN # 09316009 FILE NAME: X09-16-002C80 TER I I i o SSLLdwg f 3: c REFERENCE FILE: SHEET z I82I9-I090 BASE .dwg SSA 1 EXISTING CONDITIONS PLAN �° �� ° �° 150 PROJECT NO. STA. 35+00 TO STA. 45+47 I82I9-I090 ( IN FEET ) DWG NO.0191307-DHi LEGEND PL EXISTING PROPERTY LINE - EXISTING STREAM CENTERLINE — EXISTING CONTOUR MAJOR BASE FLOOD ELEVATION EXISTING CONTOUR MINOR AREA OF FLOODWAY 16W EXISTING 16-INCH WATER MAIN 100-YEAR FLOODPLAIN EXISTING ASPHALT 500-YEAR FLOODPLAIN W W W EXISTING WETLAND AREA LIMITS OF DISTURBANCE CLEARING AND GRUBBING LIMITS REVISION OWNER INFORMATION: # DATE 777WOWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 LIMITS OF 500 YEAR EMAIL: tim@bccgp.com Q FLOODPLAIN CAMP BRANCH LIMITS OF 100 YEAR a z w W Q a o FLOODPLAIN w o w REFERENCES: APPROXIMATE LOCATION OF EXISTING WOOD LINE 1. REFERENCE IS MADE TO A SEWER " TOPOGRAPHIC SURVEY PROVIDED BY \\\�������\\\N1��lV��'i�i,�% GRIFFIN SURVEYING SERVICES, P.A., ��cm Q DATED MARCH 15, 2019 �' 2. RERERENCE IS MADE TO NORTH = y`o �; N __ CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, y o 0 2008. • ,� W z� p,L P X O�--- PL kp N iiinnlnn��� E� �. O cm NOTES: Q EXISTING MANHOLE a a a sQ� ��.9^. 1. CAD FILES WILL BE PROVIDED TO 'ai CONTRACTOR FOR USE WITH SITE L(/ STAKING. ° °°. , 2. AS -BUILT TOPOGRAPHIC SURVEY + COMPLETED BY A LICENSED 'Q= Q to SURVEYOR TO BE PROVIDED BY Ei =vo EXISTING MANHOLE CONTRACTOR UPON PROJECT =y^ w COMPLETION. a a 4a a � V � 0 BEARSKIN CREEK �No 1 APPROXIMATE LOCATION OFF I � EXISTING WOOD LINE I I W �o 50 25 50 150 _ �N �cv CLEARING AND GRUBBING PLAN ( IN FEET) U^ 0 (STA. 0+00 TO STA. 10+00) Q .4 co O • APPROXIMATE LOCATION OF ��Nj�TS OF EXISTING WOOD LINE DI ST U&SAI�IC411 j + w C� C�M1TS OF p� v � ST URgAIV CF APPROXIMATE LOCATION OF EXISTING WOOD LINE a , a a � a a a � a P � o w. of o,s��ReANCE � � UMXZS AWN ER GRp,V11Y M Cf) Z Ep SANITARY SEW NCE \' pROPos OF p�S1UR8A UM�1S P � � D N ®- � CAMP BRANCH ` a a , a _ O a CENTER OF UN -NAMED FILE NAME: TRIBUTARY REFERENCE FILE: SHEET I82I9-I090 CLEARING AND GRUBBING PLAN BATSE.dwg SS20 50 25 50 150 PROJECT NO. (STA. 10+00 TO STA. 21 +50) I82I9-I090 ( IN FEET) DWG NO. 01,1307—D23 LEGEND PL EXISTING PROPERTY LINE — EXISTING STREAM CENTERLINE 260 EXISTING CONTOUR MAJOR ­/ 558\/\/— BASE FLOOD ELEVATION EXISTING CONTOUR MINOR I AREA OF FLOODWAY 16W EXISTING 16-INCH WATER MAIN 100-YEAR FLOODPLAIN EXISTING ASPHALT 500-YEAR FLOODPLAIN W W W EXISTING WETLAND AREA LIMITS OF DISTURBANCE CLEARING AND GRUBBING LIMITS APPROXIMATE LOCATION OF EXISTING WOOD LINE 'Q I J a J a CENTER OF UN -NAMED TRIBUTARY i Y" APPROXIMATE LOCATION OF Q� EXISTING WOOD LINE O I PR\� pISTURBA ��/ LIMITS pF 000.01 o 0 / � d CLEARING AND GRUBBING PLAN STA. 21+50 TO STA. 35+00 APPROXIMATE LOCATION OF / EXISTING WOOD LINE 1 LIN y ® CENTER OF Bq UN -NAMED TRIBUTARY PL PL s PL � pL PL BENCHMARK pL N: 453529.71 PL E: 1524648.47 PL - PL EXISTING FENCELINE SECTIONS CROSSING PROPOSED WASTEWATER EXTENSION TO BE REMOVED AND RELOCATED CLEARING AND GRUBBING PLAN (STA. 35+00 TO STA. 45+47) PL EXISTING HORSE GRAVES CENTER OF UN -NAMED TRIBUTARY 45+30 ]d ld OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. ( IN FEET ) ( IN FEET ) REVISION DATE o� a of uc Ln zz — c c N \i c a,c� 0 U ,C ;s Q GP CER1 \F pq pq C O N x � � Q z L-L] Hz � j O U �: P-� �t' U P� w P� u O FILE NAME: SS2.I.dwg REFERENCE FILE: SHEET I82I9-I090 BASE.dwg SS2 PROJECT NO. I82I9-I090 DWG NO.019D07-D23 R co co cu a 0 0 r E co cu C 0) W LEGEND PL EXISTING PROPERTY LINE o EXISTING STREAM CENTERLINE PROPOSED 8-INCH WASTEWATER GRAVITY EXISTING CONTOUR MAJOR BASE FLOOD ELEVATION PROPOSED 30-FOOT WASTEWATER EASEMENT EXISTING CONTOUR MINOR AREA OF FLOODWAY PROPOSED WASTEWATER MANHOLE 16W EXISTING 16-INCH WATER MAIN 100-YEAR FLOODPLAIN SF PROPOSED SILT FENCE EXISTING ASPHALT 500-YEAR FLOODPLAIN PROPOSED GRASSING W W W EXISTING WETLAND AREA LIMITS OF DISTURBANCE PROPOSED EROSION CONTROL MATTING PROPOSED SEDIMENT LOG PROPOSED TEMPORARY CONSTRUCTION 1 T� ENTRANCE CONSTRUCTION SEQUENCE i:7xy=1DAmmIN V LYiUJ/_lI=1Aw=1VLYiIId;ld0]►Ti NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ) 2. NOTIFY NCDEQ REGIONAL OFFICE 48 HOURS PRIOR TO LAND DISTURBANCE ACTIVITY. 3. CONDUCT PRE -CONSTRUCTION MEETING WITH NCDEQ REPRESENTATIVE, OWNER, AND CONTRACTOR TO DISCUSS THE MEASURES AND HOW TO FOLLOW SWPPP STANDARDS BEFORE WORK BEGINS. 4. CLEAR AND GRUB AS NECESSARY ALONG THE LIMITS OF DISTURBANCE FOR INSTALLATION OF PERIMETER CONTROLS AND BEST MANAGEMENT PRACTICES (BMPs) (CONSTRUCTION ENTRANCE, SILT FENCE) 5. INSTALL PROPOSED SEDIMENT TUBES AT THE TOP OF THE SLOPES OF THE BANKS TO PROTECT THE CREEK AREA BEFORE CONSTRUCTION AT THE TWO (2) CREEK CROSSINGS. 6. ONCE PERIMETER CONTROLS AND BMPs ARE IN PLACE, BEGIN INSTALLATION OF SANITARY SEWER LINE. 7. IMMEDIATELY FOLLOWING INSTALLATION AT THE TWO (2) CREEK CROSSING, INSTALL EROSION CONTROL MATTING ALONG THE BANK SLOPES. GRASS IMMEDIATELY. 8. MAINTAIN ALL EROSION AND SEDIMENT CONTROL MEASURES FOR THE DURATION OF THE PROJECT. 9. GRASS DISTURBED AREAS IMMEDIATELY UPON COMPLETION OF WORK IN THE AREA. STABILIZE THE DISTURBED AREAS AT LEAST WEEKLY UNTIL THE SITE IS RELEASED. 10. FOLLOWING COMPLETION OF UTILITY CONSTRUCTION WITHIN THE FLOODPLAIN, GROUND ELEVATIONS SHALL BE RETURNED TO THE PREDEVELOPMENT ELEVATIONS SO AS NOT TO REDUCE THE FLOOD STORAGE VOLUME OF THE FLOODPLAIN. 11. SITE GRADING SHALL NOT BE MODIFIED. EXISTING DRAINAGE PATTERNS SHALL NOT BE ALTERED AND NO NEW CONCENTRATED FLOWS SHALL BE DEVELOPED. 12. THERE SHALL BE NO PERMANENT OR TEMPORARY STORAGE OF MATERIAL OR EQUIPMENT WITHIN THE FLOODPLAIN. EROSION AND SEDIMENT CONTROL PLAN STA. 0+00 TO STA.10+00 GRASS DISTURBED AREAS EROSION AND SEDIMENT CONTROL PLAN STA. 10+00 TO STA. 21 +50 i ® -'A2WW� y OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. ( IN FEET ) ( IN FEET ) REVISION DATE IIII/1V 10/16/19 REVISIONS PER UNION CO. III IIII/-I 10/15/19 DEQ REVISIONS III o z� zQ Q o� w� a� \\\\\0 IIIIII]///, Off/ c3 ill c — _ CCJJ LL a a� U O _ U ,C �wz � CER1 \F d Q W� C) + 0 P dC) r� Q P� P � z O v W � P� O v z a FILE NAME: SS3.0.dwg REFERENCE FILE: SHEET I82I9-I090 150 BASE.dwg SS3v0 PROJECT NO. I82I9-I090 DWG NO.0191307-D23 LEGEND PL EXISTING PROPERTY LINE o EXISTING STREAM CENTERLINE 8ww PROPOSED 8-INCH WASTEWATER GRAVITY EXISTING CONTOUR MAJOR —\/,558,/\/— BASE FLOOD ELEVATION PROPOSED 30-FOOT WASTEWATER EASEMENT EXISTING CONTOUR MINOR I AREA OF FLOODWAY 0 PROPOSED WASTEWATER MANHOLE 16W EXISTING 16-INCH WATER MAIN 100-YEAR FLOODPLAIN SF PROPOSED SILT FENCE EXISTING ASPHALT 500-YEAR FLOODPLAIN \L/ PROPOSED GRASSING EXISTING WETLAND AREA LIMITS OF DISTURBANCE PROPOSED EROSION CONTROL MATTING PROPOSED SEDIMENT LOG PROPOSED TEMPORARY CONSTRUCTION TC ENTRANCE :DELINEATED` WETLAND CAMP BRANCH / CREEK J D- 1 FEMA 100—YR FLOODPLAIN J a J a � S _ F �ww < J wW UNNAMED TRIBUTARY / x / Q y WW -- 10 � S OWNER INFORMATION: OWNER: CONTACT: ADDRESS: CITY, STATE: TELEPHONE: EMAIL: 13 EXISTING GARBAGE PILE Q� Q� s 0G` G` Poo i 04 � GRASS DISTURBED _ — i I AREAS </ i S F F F III �W Fjjjj� ' � 1 � pole— FEMA 100—YR FLOODPLAIN s '� oo EROSION AND SEDIMENT CONTROL PLAN STA. 21 +50 TO STA.35+00 EXISTING ` � l BARN Y. OX F GRASS DISTURBED � � � � AREAS ` ' / DELINEATED �- ® F y / WETLAND — _ — S ® '® C ,` yS 8Ww ® mumoe i ® _ i I/ol o Sic mum kl pL PL S'mum Mftft P1 ♦ S� Fmum pL PL `♦ S,� F F � F F SF - p1- TCE � SF SF <- EROSION AND SEDIMENT CONTROL PLAN STA. 35+00 TO STA. 45+74 0 BC CONSTRUCTION GROUP, LLC MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES 400 WEST NORTH STREET, SUITE 112 RALEIGH, NORTH CAROLINA 27603 (919) 827-4140 tim@bccgp.com REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. t©� REVISION DATE 10/16/19 REVISIONS PER UNION CO. IIII/-�\I 10/15/19 DEQ REVISIONS III o o� �A NG I NEE,? O OAP 00 S J 'JN ( IN FEET ) CONSTRUCTION SEQUENCE 1. RECEIVE STORMWATER PERMIT FROM NORTH [� CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ) + 2. NOTIFY NCDEQ REGIONAL OFFICE 48 HOURS PRIOR TO LAND DISTURBANCE ACTIVITY. 3. CONDUCT PRE -CONSTRUCTION MEETING WITH NCDEQ REPRESENTATIVE, OWNER, AND CONTRACTOR TO DISCUSS THE MEASURES AND HOW TO FOLLOW SWPPP STANDARDS BEFORE WORK P BEGINS. 4. CLEAR AND GRUB AS NECESSARY ALONG THE LIMITS OF DISTURBANCE FOR INSTALLATION OF PERIMETER CONTROLS AND BEST MANAGEMENT PRACTICES Q/11U o (BMPs) (CONSTRUCTION ENTRANCE, SILT FENCE) w 5. INSTALL PROPOSED SEDIMENT TUBES AT THE TOP OF THE SLOPES OF THE BANKS TO PROTECT THE CREEK AREA BEFORE CONSTRUCTION AT THE TWO (2) w CREEK CROSSINGS. Q 6. ONCE PERIMETER CONTROLS AND BMPs ARE IN PLACE, BEGIN INSTALLATION OF SANITARY SEWER Z LINE. � O 7. IMMEDIATELY FOLLOWING INSTALLATION AT THE TWO �-+ (2) CREEK CROSSING, INSTALL EROSION CONTROL` U MATTING ALONG THE BANK SLOPES. GRASS P� IMMEDIATELY. EXISTING MANHOLE 8. MAINTAIN ALL EROSION AND SEDIMENT CONTROL Z STATION 45+47 MEASURES FOR THE DURATION OF THE PROJECT. 9. GRASS DISTURBED AREAS IMMEDIATELY UPON COMPLETION OF WORK IN THE AREA. STABILIZE THE DISTURBED AREAS AT LEAST WEEKLY UNTIL THE SITE u IS RELEASED. ` 10. FOLLOWING COMPLETION OF UTILITY CONSTRUCTION 0 [� �d WITHIN THE FLOODPLAIN, GROUND ELEVATIONS C �d SHALL BE RETURNED TO THE PREDEVELOPMENT H ELEVATIONS SO AS NOT TO REDUCE THE FLOOD STORAGE VOLUME OF THE FLOODPLAIN. P� 11. SITE GRADING SHALL NOT BE MODIFIED. EXISTING U C DRAINAGE PATTERNS SHALL NOT BE ALTERED AND � � U un O NO NEW CONCENTRATED FLOWS SHALL BE a DEVELOPED. 12. THERE SHALL BE NO PERMANENT OR TEMPORARY FILE NAME: STORAGE OF MATERIAL OR EQUIPMENT WITHIN THE SS3.I.dwg FLOODPLAIN. REFERENCE FILE: SHEET n I82I9-I090 BASE.dwg SS31PROJECT 50 25 0 50 150 NO. I82I9-I090 ( IN FEET ) DWG No. 0Il,1307-D23 II Z_N A \ EXISTING SSMH 49A A� P pL PL SHEET SS4.1-PL PL- - PL + ! j 2 r' i / \ MANHOLE #1 EXISTING SSMH 49 0 EXISTING I CENTERLINE O . \ BEARSKIN C EK DELINEATED WETLAND MANHOLE #3 . . 0 '-8. . . t * * I . MANHOLE #2 x MANHOLE #4 FEMA 100-YR . FLOODPLAIN EXISTING CENTERLINE OF CAMP BRANCH CREEK- : 1 ZONE X 1 L -\MANH MARTHA A LAND 924 ASHLEY GLEN DRIVE ID 09-316-002 #5 TJ LIMITS ZONE X CITY OF MONROE E UNION COUNN LEGEND PL EXISTING PROPERTY LINE 8WW PROPOSED 8-INCH SANITARY SEWER GRAVITY EXISTING ASPHALT PROPOSED 30-FOOT SANITARY SEWER EASEMENT W W W EXISTING WETLAND AREA PROPOSED SANITARY SEWER MANHOLE OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. EXISTING �S4.2 CENTERLINE OFEET UNNAMED � TRIBUTARY FEMA 100- FLOODPL, O i + MANHOLE #7 . \ \ 10 . . . . . . . . . . . . . . MARTHA A LAND 924 ASHLEY GLEN DRIVE 1 ID 09-316-002 DELINEATED ZONE AE WETLAND 0 SANITARY SEWER NOTES: PER CITY OF MONROE AND NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ) STANDARDS: 1. MAINTAIN MINIMUM 18-INCHES VERTICAL CLEARANCE FOR WATER MAINS INSTALLED ABOVE AND BELOW SEWER MAINS. 2. WHENEVER IT IS NECESSARY FOR A SEWER MAIN TO CROSS UNDER A WATER MAIN WITH LESS THAN 18-INCHES OF VERTICAL SEPARATION, THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE FOR A DISTANCE OF 10-FEET ON EACH SIDE OF THE POINT CROSSING BY USE OF A SINGLE PIECE OF PIPE. 3. THE SELECTION OF THE TYPE OF PIPE TO BE INSTALLED IS BASED ON THE FOLLOWING CONDITIONS PER STANDARD DETAIL 12.09.00: 3.1. DEPTH OF BURY <3 FEET SHALL ALWAYS REQUIRE THE INSTALLATION OF SEWER RATED DUCTILE IRON PIPE. 3.2. DEPTH OF BURY >20 FEET SHALL ALWAYS REQUIRE THE INSTALLATION OF SEWER RATED DUCTILE IRON PIPE. 3.3. DEPTH OF BURY <12 FEET AND >3 FEET SHALL PERMIT THE INSTALLATION OF SDR-35 PVC PIPE PROVIDED IT IS IN ACCORDANCE WITH GENERAL SEPARATION DISTANCE REQUIREMENTS. 3.4. DEPTH OF BURY >3 FEET AND <20 FEET SHALL PERMIT THE INSTALLATION OF PVC C900 DR-25. 3.5. PVC SDR-35 SHALL ALWAYS REQUIRE A MINIMUM OF TYPE III BEDDING PER THE STANDARD DETAIL 12.09.00. 3.6. PVC C900 DR-25 SHALL ALWAYS REQUIRE A MINIMUM OF TYPE II BEDDING PER THE STANDARD DETAIL 12.09.00. TYPE III MAY BE REQUIRED WHERE ROCKY CONDITIONS ARE ENCOUNTERED. 4. MANHOLE SELECTION: 4.1. MANHOLES WILL BE FURNISHED WITH THE FOLLOWING CLEAR INSIDE DIAMETERS ACCORDING TO THE SEWER MAIN DIAMETER: 8-INCH TO 12-INCH PIPE, 4-FOOT MANHOLE 4.2. THE MANHOLE DIAMETER FOR A GIVEN PIPE SIZE MAY BE INCREASED FROM THAT SHOWN ABOVE FOR APPLICATIONS WHERE THE ANGLE BETWEEN THE INFLUENT AND EFFLUENT PIPES PRECLUDES PROPER INSTALLATION OF THE PIPE CONNECTIONS IN THE STANDARD SIZE MANHOLE. 4.3. ALL MANHOLES FOR 8-INCH SEWER MAIN SHALL BE FOUR (4) FEET IN DIAMETER UNLESS OTHERWISE DIRECTED AS PER ABOVE. ALL MANHOLES CONSTRUCTED WITH AN INVERT SEPARATION OF 2.5 FEET OR GREATER SHALL INCLUDE AN OUTSIDE DROP PER STANDARD DETAIL 12.03.00. 4.4. INFLOW DISHES/INSERTS SHALL BE INSTALLED ON ALL NEW MANHOLES, FOR MAINS 12-INCHES OR LESS, WITH THE EXCEPTION TO CROSS-COUNTRY TYPE MANHOLES. 4.5. CROSS-COUNTRY MANHOLES: ALL MANHOLES LOCATED OUTSIDE OF THE PUBLIC RIGHT-OF-WAY SHALL BE CONSIDERED CROSS-COUNTRY MANHOLES AND SHALL BE DESIGNED IN ACCORDANCE WITH STANDARD DETAIL 12.02.00 OF THESE SPECIFICATIONS. ALL FRAME AND COVERS SHALL UTILIZE A COVER -TO -SWIVEL FUNCTION. MANHOLES SHALL BE 2 FEET ABOVE FINAL GRADE WITH A PERMITTED TOLERANCE OF 6-INCHES. SPECIAL CONDITIONS MAY REQUIRE THESE MANHOLES TO BE INSTALLED FLUSH WITH OR BELOW THE GROUND. WRITTEN PERMISSION FROM THE WATER RESOURCES ENGINEER SHALL BE REQUIRED BEFORE SUCH INSTALLATIONS ARE PERMITTED. 4.6. CONCENTRIC CONE MANHOLE: IN LOCATIONS WHERE THE DEPTH OF BURY OF THE MANHOLE IS LESS THAN 5 FEET A CONCENTRIC MANHOLE SHALL BE INSTALLED WITHOUT STEPS DESIGNED IN ACCORDANCE WITH STANDARD DETAIL 12.05.00. ALL OTHER MANHOLE INSTALLATIONS SHALL REQUIRE AN ECCENTRIC CONE. FLAT TOP MANHOLES SHALL NOT BE PERMITTED UNLESS A DESIGN REVIEW IS COMPLETED BY WATER RESOURCES ENGINEER AN D WRITTEN PERMISSION IS GRANTED. 4.7. RIM ELEVATIONS OF ALL MANHOLES SHALL BE SHOWN ON THE PLANS. MANHOLES WITH RIM ELEVATIONS BELOW THE 100-YEAR FLOOD ELEVATION SHALL HAVE SEALED WATERTIGHT LIDS. THESE LOCATIONS SHALL BE SHOWN ON THE PLANS. OUTSIDE VENTS FOR WATERTIGHT LID MANHOLES SHALL BE LOCATED EVERY 1000-FEET AND SHALL CONFORM TO THE PLAN DETAIL WITH THE OPENING OF THE VENT AT LEAST TWO FOOT ABOVE THE 100-YEAR FLOOD ELEVATION. PLEASE REFER TO STANDARD DETAIL 12.08.00. 'REFER TO CITY OF MONROE STANDARD SPECIFICATIONS AND DESIGN MANUAL FOR COMPLETE WASTEWATER SPECIFICATIONS. b ALEXANDER FRANK HOWARD PL' 2506 WEDDINGTON RD / ID 09-316-002E ' PL L SHEET SS4.4 SHEET SS4.3 MAN /LE MANHOLE #14 ALEXANDER FRANK HOWARD � Q� � / AND SHERRY P DELINEATED 2506 WEDDINGTON RD e00 ID 09-316-002A a � MANHOLE #12 6� � 1� 0 WETLAND MANHOLE #8 �Q'� �j �Qj X �k �✓ ox II 0p MANHOLE 415 _ 1+ 42+00 4 + 4 x0� \ 00 MANHOLE #17 CONNECTION TO MANHOLE AT APPRENTICE ACADEMY APPRENTICE ACADEMY HIGH SCHOOL BENCHMARK 4+00 5 / J / N: 453529.71 d r yk E: 1524648.74 ` 45+30 / MANHOLE #9 \ 31c3)''00 3.MANHOLE #16 / ld 2�+00 +00 26+00 7+00 / \ \ RONNIE SIMPSON 1 MANHOLE #11 \ DB. 6202-143 PG. 377 mmj PIN #09316009 MANHOLE #10 ZONE X 1 \ 0 x z PAUL E HUNTER 0 2606 WEDDINGTON RD f- ID 09-316-002C80 z ctqp GENERAL PLAN NOTES: RK ROgD PER CITY OF MONROE DEPARTMENT OF WATER RESOURCES Lu 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY OF MONROE STANDARD WATER AND SEWER SPECIFICATIONS, LATEST REVISION. 2. ALL MATERIALS INCORPORATED INTO THE WORK SHALL CONFORM TO THE CITY OF MONROE STANDARD WATER AND SEWER SPECIFICATIONS AND DETAILS, LATEST REVISION. 3. UTILITY COMPANIES MUST BE NOTIFIED A MINIMUM OF 72 HOURS IN ADVANCE OF CONSTRUCTION. CALL: ONE -CALL @ 811 OR 1-800-632-4949 4. UNDERGROUND UTILITIES SHOWN ARE BASED ON INFORMATION OBTAINED FROM AVAILABLE RESOURCES. THE CONTRACTOR IS CAUTIONED THAT THESE LOCATIONS ARE NOT GUARANTEED NOR IS THERE GUARANTEE THAT ALL SUCH LINES IN EXISTENCE ARE SHOWN ON THE PLANS. THE CONTRACTOR IS RESPONSIBLE TO PERFORM ALL WORK CAREFULLY AND PROTECT EXISTING UTILITIES FROM DAMAGE. 5. THE CONTRACTOR SHALL CONSTRUCT TEST PITS AT ALL UTILITY CROSSINGS TO DETERMINE EXACT LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES BEFORE COMMENCING CONSTRUCTION. 6. WHENEVER IT IS NECESSARY FOR A SEWER MAIN TO CROSS UNDER A WATER MAIN WITH LESS THAN 18-INCHES OF VERTICAL SEPARATION THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE FOR A DISTANCE OF TEN (1 0)-FEET ON EACH SIDE OF THE POINT OF CROSSING BY USE OF A SINGLE PIECE OF PIPE, UNLESS AN EXCEPTION IS GRANTED BY THE WATER RESOURCES ENGINEERING MANAGER OR THEIR AUTHORIZED REPRESENTATIVE. SHOULD THE SEWER MAIN CROSS OVER A WATER MAIN, BOTH MAINS SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE WITH ONE FULL LENGTH OF PIPE (MIN. OF 20-FEET) INSTALLED SO BOTH JOINTS WILL BE EQUIDISTANT FROM THE UTILITY. 7. THE WORK SITE AND EQUIPMENT SHALL BE SECURED AT THE END OF EACH DAY AND ALL OTHER TIMES WHEN CONSTRUCTION PERSONNEL ARE NOT ON -SITE. EQUIPMENT SHALL BE PLACED IN LINEAR FASHION ALONG THE EDGE OF THE VEHICLE TRAVEL AREA AND SHALL BE DELINEATED WITH APPROVED WARNING SIGN S /DEVICES. EMERGENCY VEHICLE ACCESS SHALL BE AFFORDED TO THE RESIDENTS AND NORMAL COLLECTION OF GARBAGE, COMMERCIAL DELIVERIES, AND SCHOOL BUS TRAFFIC IS TO BE PROVIDED. EQUIPMENT SHALL BE LOCKED AND INCAPABLE OF OPERATION. THERE SHALL BE NO PERMANENT OR TEMPORARY STORAGE OF MATERIAL OR EQUIPMENT WITHIN THE FLOODPLAIN. 8. ONLY CITY EMPLOYEES ARE AUTHORIZED (UNLESS APPROVED BY THE CITY OF MONROE WATER RESOURCES DEPARTMENT) TO OPERATE LINE VALVES. 9. ALL FIELD REVISIONS (DURING CONSTRUCTION) TO THE PROPOSED ALIGNMENT OF THE SYSTEM IM 10. ALL ROADWAY REPAIR WORK WITHIN THE STATE AND CITY RIGHT-OF-WAYS SHALL CONFORM TO CITY STANDARD SPECIFICATIONS AND DETAILS MANUAL OR THE NCDOT LATEST SPECIFICATIONS AND DETAILS MANUAL. 11. FOR WORK WITHIN PAVEMENT AREAS, TRENCH EXCAVATION SHALL NOT EXCEED THE LENGTH OF THE MAIN INSTALLATION THAT CAN BE PROPERLY BACKFILLED AND COMPACTED WITHIN THE WORK PERIOD. PAVEMENT REPAIR SHALL BE REQUIRED TO BE COMPLETED WITHIN A 24-HOUR PERIOD OR THE SAME DAY IF RAIN IS IMMINENT. 12. ALL ROADWAY SIGNS WHICH ARE REMOVED TO FACILITATE INSTALLATION SHALL BE REINSTALLED IMMEDIATELY. 13. EXCAVATIONS SHALL BE FILLED OR PLATED AND DELINEATED/SECURED AS REQUIRED, WITH APPROVED DEVICES (FLASHERS, CONES, BARRICADES, FENCING, ETC.). 14. CONTRACTORS SHALL INSTALL WITH PVC AND DIP WATER MAIN, A PLASTIC COATED #12 GAUGE, STRANDED COPPER TRACING WIRE. WIRES SHALL BE DUCT TAPED TO THE PIPE DURING INSTALLATION. INSTALLATION OF WIRES SHALL BE CONTINUOUS WITH THE WATER MAIN, INCLUDING FIRE HYDRANT LEGS AND INTERSECTIONS. SPLIT BOLTS SHALL BE REQUIRED TO ATTACH WIRE AT THESE INTERSECTIONS AND LEGS. 15. THE CONTRACTOR SHALL REPAIR ANY AND ALL DAMAGES CAUSED BY HIM DURING THE COURSE OF THE CONSTRUCTION. 16. THE CONTRACTOR SHALL BE RESPONSIBLE TO SECURE ALL WORK PERMIT(S) FOR WORK WITHIN THE NCDOT AND CITY RIGHT-OF-WAYS. THE CONTRACTOR SHALL CONSTRUCT THE PROPOSED IMPROVEMENTS SET FORTH AS CONDITIONS OF THE PERMIT(S). 17. A PERMITTED (CITY OF MONROE WATER/SANITARY SEWER, NCDOT, AND/OR OTHER AGENCY HAVING JURISDICTION) SET OF PLANS SHALL BE ON -SITE AT ALL TIMES DURING CONSTRUCTION. ( IN FEET ) REVISION DATE 10/16/19 REVISIONS PER UNION CO. 10/15/19 DEQ REVISIONS o z� zQ Q o� G INEE �Q`' ;O0 � Sill C7 b I I C 0 u P C u FILE NAME: SS4.0.dwg REFERENCE FILE: SHEET I82I9-I090 BASE.dwg SS4 PROJECT NO. I82I9-I090 DWG NO.0191307-D23 1-1 LEGEND PL EXISTING PROPERTY LINE 8WW PROPOSED 8-INCH SANITARY SEWER GRAVITY EXISTING ASPHALT PROPOSED 30-FOOT SANITARY SEWER EASEMENT EXISTING WETLAND AREA PROPOSED SANITARY SEWER MANHOLE 80 LF OF 21" STEEL CASING PIPE CENTERED AT STREAM CROSSING _ (RESTRAINED JOINT SEWER RATED DIP TO BE PLACED IN CASING) EXISTING MANHOLE EXISTNG 18-INCH PVC SANITARY SEWER LINE 600 598 596 594 592 590 588 586 584 582 580 578 576 574 572 570 568 DATUM ELEV 566.00 6 6r. Lr. CONNECT TO EXISTING MH49 STA. 0+00.00 RIM: 580.95 INV IN: 574.35 12" DIP INV OUT: 571.85 18" PVC (INSTALL OUTSIDE DROP UNIT FOR CONNECTION) PL 80 LF OF 21" STEEL CASING PIPE CENTERED AT STREAM CROSSING (RESTRAINED JOINT SEWER RATED DIP TO BE PLACED IN CASING) Qv N PROPOSED MANHOLE #1 STA. 3+98.60 RIM: 582.29 TOP OF VENT; 586.52 (WATERTIGHT LID) INV IN: 575.57 12" DIP INV OUT: 575.47 12" DIP APPROXIMATE LOCATION OF EXISTING TREE LINE I EXISTING CENTER LINE I OF CAMP BRANCH I DELINEATED WETLAND EXISTING STREAM sx oo Ln -00\ PROPOSED 30' SEWER I EASEMENT, TYPICAL PROPOSED LIMITS OF DISTURBANCE, TYP. PROPOSED MANHOLE #2 STA. 6+97.36 RIM: 587.00 (SWIVEL LID) INV IN: 576.51 12" PVC INV OUT: 576.41 12" DIP SANITARY SEWER PLAN lJ I /"X. U-rUU I u J l /"X. I U-rUU) NOTES: 1. CONTRACTOR TO GRADE A 15-FOOT ACCESS PATH ALONG WASTEWATER ALIGNMENT PER CITY OF MONROE REQUIREMENTS IN AREAS OF STEEP SLOPE FOR BETTER ACCESS. IF THERE ARE QUESTIONS, PLEASE DISCUSS WITH ENGINEER OF RECORD AND CITY OF MONROE INSPECTOR BEFORE CONSTRUCTION BEGINS. 2. ALL RIM ELEVATIONS SHOULD BE CONSTRUCTED 2-FEET ABOVE GRADE, AND VENTS 2-FEET ABOVE 100-YEAR FLOOD ELEVATION. 3. ALL CROSS-COUNTRY MANHOLES ARE TO HAVE SWIVEL LIDS UNLESS NOTED TO BE WATER TIGHT. PROPOSED MANHOLE #4 STA. 9+11.93 RIM: 583.75 (WATERTIGHT LID) INV IN: 577.31 12" PVC INV OUT: 577.21 12" PVC I PROPOSED MANHOLE #3 STA. 8+30.61 RIM: 584.94 (WATERTIGHT LID) 9+00 INV IN: 576.98 12" PVC INV OUT: 576.88 12" PVC 81.32' OF 12" SDR-35 PVC @ 0.28% 1 EXISTING STREAM �® a Q DELINEATED WETLAND co � �I ( IN FEET ) � � N U) I U) W W W I W ':'E^ ':'E^ vJ vJ NNECT EXISTING MH OLE #1 : 3+98.60 • 582• TOP OF VEN :586.52 - 94 STA:9+11.93 RIM:583.715 49 TA:6+97.36 STA:8+30.61 STA:0+00.00 R F. 5 RIM:587.02 RI :584.94 INV 12" DIP INV .85 18" PVG OUTSIDE UNIT FOR CONNECTION 19' OF CAMP BRANCH STREAM CROSSING RATED DIP 0.98% (WATERTIGH INV IN: 575.57 LID) (SWIVEL LID) (WATERTIGHT LID) (WATERTIGHT LID) NV IN:577.31 12" PVU 12" DIP 100-Y FLOOD E EVATION:584.9 17' OF BEARSKIN CROSSING ISTING EXGRADE 81.32' @ 0.28% 133.25' OF 12' SDR-35 PVC 0.28% OF 12" SDR-35 PVC 80 LF OF 21" STEEL CASING PIPE CENTERED AT STREAM CROSSING (RESTRAINED JOINT SEWER RATED DIP TO BE PLACED IN CASING) " EWER RATED DIP 0.28% 398.60' 12" SEWER RAIN 80 LF OF 21" STEEL CASING PIPE CENTERED AT CROSSING (RESTRAINED JOINT SEWER RATED DIP TO BE PLACED IN CASING) 3.5' MAN' ILL! J 7 0) I- ti Ln Ln 0) ti r` Ln Ln O 0) O ti 00 r- N- Ln Ln O O O 7 00 00 r­ N. Ln Ln O O 7 00 00 ti r­ I,-rl- Lo Ln O m c0 O ti c0 rl- Ln Ln m co O I: cfl O r� 00 Ln Lo cc N � O O O 00 00 o Lo N Lo O N� O r` 00 Lo Ln Lo It ' rl- 00 r` r� Ln Lo It (fl � 00 00 r� � r V) Ln ro `l: 00 m � N. Ln Ln r- 00 `l: 0) M � 00 Ln Lo 00 O `l: O Lo Lo 00 00 V) Ln O 00 O 0) Ln M 00 00 Ln Ln 00 ro 0) O Lo It 00 00 Ln Ln c0 r` O Ln It 00 00 Ln Ln rl- Lo Ln N 00 00 Ln Ln Lo Lo N Ln 00 00 Ln Ln Lo Ln cy) 00 00 Ln Ln 600 598 596 594 592 590 588 586 584 582 580 578 576 574 395.95' OF 12" SDR-35 PVC @ 57:0.28% 570 568 566 cn 00 Lo 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 SANITARY SEWER PROFILE (STA 0+00 TO STA. 10+00 SCALE: HORIZONTAL - 1" = 50' VERTICAL - 1" = 5' OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com 1 REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. REVISION DATE 10/16/19 REVISIONS PER UNION CO. 10/15/19 DEQ REVISIONS o� zz NV� �- aa) U LL- �wz � '< GP �V CER1 \F 1111m\0 N I NEE 00 O � r N d z 0 S 10 i� 31 3 l C) C) P o o 0 FILE NAME: SS4.I.DWG REFERENCE FILE: I82I9-I090 BASE.dwg PROJECT NO. I82I9-I090 N N � t o W� 00 � w • �" 0 O�^ u°O� 0 a "d� SHEET SS4,1 DWG No. 0Il,1307-D23 II LEGEND PL EXISTING PROPERTY LINE 8WW PROPOSED 8-INCH SANITARY SEWER GRAVITY EXISTING ASPHALT PROPOSED 30-FOOT SANITARY SEWER EASEMENT W W W EXISTING WETLAND AREA PROPOSED SANITARY SEWER MANHOLE I NOTES: 1. CONTRACTOR TO GRADE A 15-FOOT ACCESS PATH ALONG WASTEWATER ALIGNMENT PER CITY OF MONROE REQUIREMENTS IN AREAS OF STEEP SLOPE FOR BETTER ACCESS. IF THERE ARE QUESTIONS, PLEASE DISCUSS WITH ENGINEER OF RECORD AND CITY OF MONROE INSPECTOR BEFORE CONSTRUCTION BEGINS. 2. ALL RIM ELEVATIONS SHOULD BE CONSTRUCTED 2-FEET ABOVE GRADE, AND VENTS 2-FEET ABOVE 100-YEAR FLOOD ELEVATION. 3. ALL CROSS-COUNTRY MANHOLES ARE TO HAVE SWIVEL LIDS UNLESS NOTED TO BE WATER TIGHT. PROPOSED MANHOLE #5 II .88 12+00 13+00 RIM: 58600 20x00 I 10 00 11+00 TOP OF VENT: 587.77 395.95' OF 12" SDR-35 PVC @ 0.28% (SWIVEL LID T INV IN: 578.52 12" PVC QJG T INV OUT: 578.42 12" PVC APPROXIMATE O I ui z � s LOCATION OF 74X '� EXISTING WOOD LINE 0 T 3 Q' T 0�7 T " T O x O � SAC DELINEATED SXOO olo PROPOSED MANHOLE #7 WETLAND O @O T STA.18+11.44 T RIM:586.93 (SWIVEL LID) N 5� T INV IN: 580.13 12" PVC T � T INV OUT: 580.03 12" PVC O p T ' 50 25 T PROPOSED MANHOLE #6 DELINEATED STA. 16+29.26 T WETLAND RIM:586.56 - (SWIVEL LID) INV IN: 579.52 12" PVC T INV OUT: 579.42 12" PVC SE. X 0. ( IN FEET ) SANITARY SEWER PLAN Nc? c I cn (STA. 10+00 TO STA. 21+50) cIcn W W W I W 2 2 W IW I L7 cn I L7 600 598 596 594 592 590 588 586 584 582 580 578 576 574 572 570 DATUM ELEV 568.00 r r u _ EXISTING ANHOLE #7 TA: 1 + MANHOLE 5 STA:13+07.88 RI :586.00 MANHOLE STA 16+29-26 RIM: 86.56 (SWIVEL LID) V IN:579.52 12" P 100-YR FLOOD ELEVATION: 586.04 RIM:586.93 EN (SWIVEL ID) INV IN:578. 2 12" PVC INV IN:58 .13 12" PVC INV OUT:5 8.42 12" PVC 10/ATI FLOOD El F 100-YR FLOO E�TION:586.32 - GRADE " -35 PVC 0.28% 1� _ 8°0 " VC Ccp 321.38' OF 1 " SDR-35 PVC(cp 0.28% Li i 0.28% W Z_ J r U Q Q LO I- N m m 00 00 LO LO LO M N (O co Nt 00 00 LO LO M (O M Nt LO 00 co LO LO "t M M 17 LO LO 0o co LO LO M M 17 M LO Nt 0o co LO LO M M r- Nt m 0o co LO LO N r- N cn m 0o co LO LO N N N M m Nt 0o co LO LO N co M �� � LO 00 00 LO LO co O 17 LO co 00 00 LO LO O co 17 O co LO 00 00 LO LO co O O N LO Nt 00 00 LO LO O NtNt N O Nt I- 00 co LO LO O I- co 0o co LO LO co (O co LO 0o co LO LO co co (O 0) LO Nt 0o co LO LO (O r 0) O Nt LO 0o co LO LO r- 00 O N LO co 0o co LO LO 00 N co LO 00 00 LO LO O (O LO LO 00 00 LO LO O O (O 00 LO LO 00 00 LO LO O m 00 M LO co 00 00 LO LO m co M (O co co 00 co LO LO 600 598 596 594 592 590 588 586 584 582 580 578 576 574 572 570 568 00 co 00 LO 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. REVISION DATE 10/16/19 REVISIONS PER UNION CO. 10/15/19 DEQ REVISIONS > z W Q o No _NG I N EfR � \y OV0 00 >� r N n a o %y d z 1 S 1 g3 "d� w � � w d Q u u z H °z W a un � P� HZ z FILE NAME: SS4.2.dwg REFERENCE FILE: ,SHEET I82I9-I090 SANITARY SEWER PROFILE (STA 10+00 TO STA. 21+50) BASE.dwg SS42 SCALE: HORIZONTAL - 1 " = 50' PROJECT NO. VERTICAL - 1" = 5' I82I9-I090 DWG No. 0Il,1307-D23 II 0 N 06 N N Q O U 0 LEGEND PL EXISTING PROPERTY LINE 8WW PROPOSED 8-INCH SANITARY SEWER GRAVITY EXISTING ASPHALT PROPOSED 30-FOOT SANITARY SEWER EASEMENT W W W EXISTING WETLAND AREA PROPOSED SANITARY SEWER MANHOLE N V. M �C6 q /GO 7> '4u �S AG DELINEATED 2 WETLAND N I- W W 2 610 608 606 604 602 600 598 596 594 592 590 588 586 584 582 580 DATUM ELEV 578.00 a a Lf o? PROPOSED MANHOLE #8 STA. 22+06.97 RIM: 587.60 (WATERTIGHT LID) INV IN: 581.34 8" DIP INV OUT: 581.24 12" PVC 80.45' OF 8" SEWER RATED DIP @ 0.50% 101 24+00 PROPOSED MANHOLE #9 STA. 23+63.51 RIM: 588.20 (SWIVEL LID) INV IN: 582.22 8" PVC INV OUT: 582.12 8" PVC CENTER OF UN -NAMED TRIBUTARY 25+00 3�g 2S' OF 8,. SD R 35 F,VC @ 0 26+00 PROPOSED MANHOLE #10 STA. 26+81.76 RIM: 591.31 (SWIVEL LID) INV IN: 583.91 8" PVC � 29+00 INV OUT: 583.81 8" PVC 28+uu $�OF 8„ SDR-35 pUC 7+00 399 • pL PL NOTES: 1. CONTRACTOR TO GRADE A 15-FOOT ACCESS PATH ALONG WASTEWATER ALIGNMENT PER CITY OF MONROE REQUIREMENTS IN AREAS OF STEEP SLOPE FOR BETTER ACCESS. IF THERE ARE QUESTIONS, PLEASE DISCUSS WITH ENGINEER OF RECORD AND CITY OF MONROE INSPECTOR BEFORE CONSTRUCTION BEGINS. 2. ALL RIM ELEVATIONS SHOULD BE CONSTRUCTED 2-FEET ABOVE GRADE, AND VENTS 2-FEET ABOVE 100-YEAR FLOOD ELEVATION. 3. ALL CROSS-COUNTRY MANHOLES ARE TO HAVE SWIVEL LIDS UNLESS NOTED TO BE WATER TIGHT. APPROXIMATE LOCATION OF EXISTING TREE LINE PROPOSED MANHOLE #11 STA. 30+81.57 RIM: 598 38 (SWIVEL LID) INV IN: 590.01 8" PVC INV OUT: 589.91 8" PVC 3� i W 30+00 / CENTER OF UN -NAMED 1•50% PL / ' TRIBUTARY - PL SANITARY SEWER PLAN (STA. 21+50 TO STA. 35+00) N NN` � PROPOSED MANHOLE #12 STA. 34+80.18 `✓� RIM: 605.26 (SWIVEL LID) INV IN: 593.51 8" PVC 0 INV OUT: 593.33 8" PVC 35x` OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com V_I 3�'`0° Q5t ( IN FEET ) REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. o?I MANHOLE #12 STA:34+80.18 RIM:605.26 (S MANHOLE STA: + RIM:587.6 8 STA:23+6 3.51 ST :26+81.76 ST :30+81.57 RIM:588.20 RIM:591.31 RI :598.38 (SWIVEL ID) (SWIVEL LID) 85$ INV IN:581. 4 8" DIP V I INV OUT:5 1.24 12" PVC / 100-YR FLOOD 100-YR FL 100-YR F ELEVATION: 587.94 ELEVATI N: 587.97 ,-80.45' OF 8" SEWER RATED DIP @ 0.50% " W -_ 76.09' OF 8" SDR-35 PVC @ 0.50% H w 832zo 50.00' OF 8" C900 DR-25 PVC - @ 0.83% 94.18' OF 8" PVC SDR-35 @ 0.83% EXISTING GRAD H Q °o °o (O (O (6 lf) °o °o Lo Lo °o � (O N lf) 4 °o °o Lo Lo (O N M 4 lf) °o °o Lo Lo (O M M Lri (6 °o °o Lo Lo r- M °o (6 (6 °o °o Lo Lo r- O °o Lo (6 6 °o °o Lo Lo O O In 6 °o � Lo Lo O 0') N N � � Lo Lo 0') M N I- N � � Lo Lo M Lo r- O � � Lo Lo Lo °o (O O � � Lo Lo °o °o (O (6 � � Lo Lo °o (6 °o � � Lo Lo M °o r_� � � Lo Lo M M 0') (6 � � Lo Lo M °o 0') 0) (6 � � Lo Lo °o N 0) N (6 � � Lo Lo N °o N M (6 4 � � Lo Lo °o N M co 4 (6 � � Lo Lo N co (6 °o � � Lo Lo 0') °o (6 � CF) Lo Lo 0') O r- (O (6 CF) O Lo (0 O (O (O °o L6 O O (0 (0 (O I- °o °o L6 (6 O O (0 (0 r- °o N (6 4 O O (0 (0 N Lo 4 N O O (0 (0 m Lo °o N 4 O O (0 (0 Cn W W 2 U) 610 608 606 604 602 600 598 596 594 592 590 588 586 584 582 580 578 o) 00 4 0 D 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00 28+50 29+00 29+50 30+00 30+50 31+00 31+50 32+00 32+50 33+00 33+50 34+00 34+50 35+00 SANITARY SEWER PROFILE (STA. 21+50 TO STA. 35+00) SCALE: HORIZONTAL - 1" = 50' VERTICAL - 1" = 5' REVISION DATE 10/16/19 REVISIONS PER UNION CO. 10/15/19 DEQ REVISIONS z z W Q a o O� = U L' c c N 0 U a) U 0_ U ,C �wz � CER1 \F w Q \\\\\\Mi I I I III//// N,�,NG I NE a 00 / N � W z ,IIIIIIIAI ```\\\ l C) P C P � � d Q z U zz FILE NAME: SS4.3.dwg REFERENCE FILE: ,SHEET I82I9-I090 BASE.dwg SS43 PROJECT NO. I82I9-I090 DWG NO. 0Il,1307-D23 LEGEND PL EXISTING PROPERTY LINE 8WW PROPOSED 8-INCH SANITARY SEWER GRAVITY EXISTING ASPHALT PROPOSED 30-FOOT SANITARY SEWER EASEMENT W W W EXISTING WETLAND AREA PROPOSED SANITARY SEWER MANHOLE PROPOSED MANHOLE #13 - STA. 36+82.46 RIM: 607.44 (SWIVEL LID) INV IN: 594.62 8" PVC i INV OUT: 594.52 8" PVC co � 'i 'i C/) c/) I- I-_ Lu w Lu Lu 2 2 C/) c/) 636 634 632 630 628 626 624 622 620 618 616 614 612 610 608 606 604 602 600 598 596 594 592 DATUM ELEV 590.00 rn cq 0 co +0 Q25.65' OF 8" SDR-35 PVC�- +��o o-or PROPOSED MANHOLE #14 STA. 38+08.11 RIM: 602.64 (SWIVEL LID) INV IN: 595.50 8" PVC INV OUT: 595.25 8" PVC � 104 CENTER OF UN -NAMED TRIBUTARY 2 *0039�00 _ 3? PROPOSED MANHOLE #15 STA. 40+13.03 RIM: 611.80 (SWIVEL LID) INV IN: 602.40 8" DIP INV OUT: 602.30 8" DIP 42+00 43+00 �X 425.67' OF 8" SDR-35 PVC @ 3.97% X 2 PL DELINEATED WETLAND 3.32% 40+00 41+00 i SANITARY SEWER PLAN (STA. 35+00 TO STA. 45+47) APPROXIMATE LOCATION OF EXISTING TREE LINE EXISTING 16-INCH WATERMAIN PROPOSED MANHOLE #16 STA. 44+38.70 RIM: 628.32 (SWIVEL LID) INV IN: 620.62 8" PVC INV OUT: 619.30 8" PVC 44+00 ' 9.* m -27.06' OF 8" SDR-35 PVC @ 6.99% 10' X 10' RECEIVING PIT ±34 LF OF 8-INCH RESTRAINED JOINT SEWER RATED DIP CARRIER PIPE AND 16-INCH STEEL CASING PIPE TO BE INSTALLED UNDER WEDDINGTON ROAD USING JACK AND BORE I I I 43.38' OF 8" SEWER RATED DIP @ 6.98% + 0�- 45+30 21.01' OF@6.97% J I� O Z I 30' X 10' BORE PIT = PROPOSED MANHOLE #17 STA. 45+30.14 RIM: 634.18 (SWIVEL LID) INV OUT: 627.00 8" PVC ( IN FEET ) MANHOLE #17 STA:45+30.14 RIM:634.18 (SWIVEL LID) INV OUT:627.00 8" PVC NHOLE #14 TA:3 + - I G WAY #16 MANHOLE STA:44+38.70 RIM:628.32 (bVVIVEL INV IN0620.62 LID) 8" PVC (MAINTAIN EXISTING 16-INCH WATER 18" V RITCAL CLEA MAIN ANCE :36+82.46 :607.44 IVEL LID) :594.62 8" PVC 94.52 8" PVC ER CITY OF MONROE STANDARDS) - I / 10' X 10' RECEIVING PIT L'OF ST RI RIM:602.64 8" PVC (S (SWIVEL LID) INV IN:595.5 AN STA:40+ RIM:611. 0 (SWIVEL ID) INV IN:60 .40 8" PVC UT:6130 8" / / i / 27.06 8" SDR-35 o o ° J Q - 0 m N °O 0� Nt Nt 0 0 N I- 0� 0� Nt Lo 0 0 I- °o 0� [_� Lo Lo 0 0 °o [_� 17 Lo Nt 0 0 � O 17 Nt m o m O (O M m O m o (O M M O N 0 0 M M N Nt 0 0 °o M O Nt (p 0 0 °o O (p m 0 0 m M m co 0 m M O co I- co O 0� I- °o M Nt 0� °o m Nt O O� m °o O N O� °o °o N O °O °o m O Lo °O °O m N Lo °O O N I- Lo O I- co Lo co OWNER INFORMATION: OWNER: BC CONSTRUCTION GROUP, LLC CONTACT: MR. TIMOTHY LEMOINE, DIRECTOR OF DEVELOPMENT SERVICES ADDRESS: 400 WEST NORTH STREET, SUITE 112 CITY, STATE: RALEIGH, NORTH CAROLINA 27603 TELEPHONE: (919) 827-4140 EMAIL: tim@bccgp.com 1 636 634 632 630 628 30' X 10' 626 BORE PIT �21.01' OF 8" SDR-35 PVC 624 @ 6.97% 622 - ± 44 LF OF 8" RESTRAINED JOINT SEWER RATED DIP CARRIER PIPE 620 AND 16" STEEL CASING PIPE TO BE INSTALLED UNDER WEDDINGTON 618 ROAD USING JACK AND BORE 616 614 612 610 608 606 604 602 600 598 596 594 592 590 35+00 35+50 36+00 36+50 37+00 37+50 38+00 38+50 39+00 39+50 40+00 40+50 41+00 41+50 42+00 42+50 43+00 43+50 44+00 44+50 45+00 45+46.71 SANITARY SEWER PROFILE (STA 35+00 TO STA. 45+47 SCALE: HORIZONTAL - 1 " = 50' VERTICAL - 1" = 5' REFERENCES: 1. REFERENCE IS MADE TO A SEWER TOPOGRAPHIC SURVEY PROVIDED BY GRIFFIN SURVEYING SERVICES, P.A., DATED MARCH 15, 2019 2. RERERENCE IS MADE TO NORTH CAROLINA FLOOD INSURANCE RATE MAP PANEL 5425, DATED OCTOBER 16, 2008. NOTES: 1. CAD FILES WILL BE PROVIDED TO CONTRACTOR FOR USE WITH SITE STAKING. 2. AS -BUILT TOPOGRAPHIC SURVEY COMPLETED BY A LICENSED SURVEYOR TO BE PROVIDED BY CONTRACTOR UPON PROJECT COMPLETION. REVISION DATE 10/16/19 REVISIONS PER UNION CO. 10/15/19 DEQ REVISIONS o o� N �NG IEO L ;Oo 00 -U w po 0 0 W z l C C) 0 I I "d� w w � w Q u z O U w P� P� u U O FILE NAME: SS4.4.dwg REFERENCE FILE: SHEET I82I9-I090 BASE.dwg SS4 4 PROJECT NO. I82I9-I090 DWG NO. 0Il,1307-D23 GENERAL NOTES: 1. FENCE FABRIC SHALL BE A MINIMUM OF 24" ABOVE GROUND SURFACE AND SHALL HAVE A MINIMUM OF 6 LINE WIRES WITH 6" STAY SPACING. 2. FILTER FABRIC SHALL BE MIRAFI 100 FABRIC OR EQUIVALENT. 3. BURLAP CANNOT BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD OF MORE THAN 30 DAYS. 4. STEEL POSTS SHALL BE 5-0" IN HEIGHT AND BE OF THE SELF -FASTENER ANGLE STEEL TYPE. 5.ORANGE SAFETY FENCE IS REQUIRED AT BACK OF SILT FENCE WHEN GRADING IS ADJACENT TO STREAMS OR WETLANDS. THE COLOR ORANGE IS RESERVED FOR VISUAL IDENTIFICATION OF ENVIRONMENTALLY SENSITIVE AREAS. 6.DO NOT INSTALL SEDIMENT FENCE ACROSS STREAMS, DITCHES, WATERWAYS, OR OTHER AREAS OF CONCENTRATED FLOW. 7.DRAINAGE AREA CAN NOT BE GREATER THAN 1 /4 ACRE PER 100 FT OF FENCE FOR SLOPES LESS THAN 2%. &SLOPE LENGTHS CAN NOT EXCEED CRITERIA SHOWN IN TABLE 6.62A NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. MIN. 10 GA. LINE WIRES. SEE NOTE NO. 17 DETAIL 03.16.01 MIN STEEL POST FILTER FABRIC EXISTING GROUND ANCHOR SKIRT A MINIMUM OF 8" MAINTENANCE: INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. PLASTIC OR WIRE TIES MIN. 14 GA. STEEL INTERMEDIATE WIRES WITH A MAX. MESH SPACING OF 6 IN. REFERENCE NCDENR PLANNING AND DESIGN MANUAL, JUNE 2006 REVISIONS FILE: I:New_I/Maps-Details/Detail Manual&Specs/ ° F df p `�� 1 1 1 1V1 1 V 1 � Y OF � ifO � T j�OE CITY Standard Detail & Spec Manual/Standard Details/03 NO. DATE DESCRIPTION DRAWN BY: JAM DATE: 08-07-01 2004 FENCE HEIGHT, REN. MOD POST OPTION LB 44 SILT FENCE INSTALLATION UNION CO LINTY NORTH CAROLINA CHECKED BY: JNL SCALE: N.T.S. 2 5 C8 ADD NOTES 5,6,7,6 AND MAINTENANCE PREPARED BY. 3 4 „ RENO E ALTERNATIVE BUR NG METHOD CAR� ENGINEERING DEPARTMENT DETAIL 03.01.01 1 5.0 SILT FENCING DETAIL CI (1DD IAI(ZTAI I ATIr)K1 1 6" (15cm) I 3" -1 \\ \\ \\\/\ 1. PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL PRODUCTS (RECPs), INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELL-O-SEED, DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE RECPs IN A 6" (15cm) DEEP x 6" (15cm) WIDE TRENCH WITH APPROXIMATELY 12" (30cm) OF RECPs EXTENDED BEYOND THE UP -SLOPE PORTION OF THE TRENCH. ANCHOR THE RECPs WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30cm) PORTION OF RECPs BACK OVER SEED AND COMPACTED SOIL. SECURE RECPs OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30cm) APART ACROSS THE WIDTH OF THE RECPs. 3. ROLL THE RECPs (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. RECPs WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL RECPs MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM TM, STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4. THE EDGES OF PARALLEL RECPs MUST BE STAPLED WITH APPROXIMATELY 2"-5" (5cm-12.5cm) OVERLAP DEPENDING ON RECP TYPE. 5. CONSECUTIVE RECPs SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3" (7.5cm) OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12" (30cm) APART ACROSS ENTIRE RECP WIDTH. NOTE: IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15cm) MAY BE NECESSARY TO PROPERLY SECURE THE RECPs. 4 EROSION CONTROL BLANKET DETAIL 5.0 6-INCHvIN. AVERAGE STONE DIAMETER OF 2 TO 3-INCHES WITH A 6-INCH MINIMUM DEPTH UNDERLYING NON -WOVEN GEOTEXTILE FABRIC SPECIFICATION SIZE ROCK PAD THICKNESS 6 INCHES ROCK PAD WIDTH 24 FEET ROCK PAD LENGTH 100 FEET ROCK PAD STONE SIZE D = 2-3 INCHES CONSTRUCTION ENTRANCE - GENERAL NOTES 1. Stabilized construction entrances should be used at all points where traffic will egress/ingress a construction site onto a public road or any impervious surfaces, such as parking lots. 2. Install a non -woven geotextile fabric prior to placing any stone. 3. Install a culvert pipe across the entrance when needed to provide positive drainage. 4. The entrance shall consist of 2-inch to 3-inch D50 stone placed at a minimum depth of 6-inches. 5. Minimum dimensions of the entrance shall be 24-feet wide by 100-feet long, and may be modified as necessary to accommodate site constraints. 6. The edges of the entrance shall be tapered out towards the road to prevent tracking at the edge of the entrance. 7. Divert all surface runoff and drainage from the stone pad to a sediment trap or basin or other sediment trapping structure 8. Limestone may not be used for the stone pad. EDGES SHALL BE TAPERED OUT TOWARDS ROAD TO PREVENT TRACKING OF MUD ON THE EDGES PLAN SYMBOL CONSTR. ENTRANCE - INSPECTION & MAINTENANCE 1. The key to functional construction entrances is weekly inspections, routine maintenance, and regular sediment removal. 2. Regular inspections of construction entrances shall be conducted once every calendar week and, as recommended, within 24-hours after each rainfall even that produces 1/2-inch or more of precipitation. 3. During regular inspections, check for mud and sediment buildup and pad integrity. Inspection frequencies may need to be more frequent during long periods of wet weather. 4. Reshape the stone pad as necessary for drainage and runoff control. 5. Wash or replace stones as needed and as directed by site inspector. The stone in the entrance should be washed or replaced whenever the entrance fails to reduce the amount of mud being carried off -site by vehicles. Frequent washing will extend the useful life of stone pad. 6. Immediately remove mud and sediment tracked or washed onto adjacent impervious surfaces by brushing or sweeping. Flushing should only be used when the water can be discharged to a sediment trap or basin. 7. During maintenance activities, any broken pavement should be repaired immediately. 8. Construction entrances should be removed after the site has reached final stabilization. Permanent vegetation should replace areas from which construction entrances have been removed, unless area will be converted to an impervious surface to serve post -construction. 2 \ CONSTRUCTION ENTRANCE DETAIL 5.0 EROSION CONTROL BLANKET INSPECTION AND MAINTENANCE Inspect areas protected by ECBs for dislocation or failure every 7 calendar days. Conduct regular inspections until grasses are firmly established. Adhere to the pinning or stapling pattern as shown on the Manufacturer's installation sheet. If there is evidence that the ECB is not securely fastened to the soil, require extra pins or staples to inhibit the ECB from becoming dislodged. If washout or breakage occurs, repair all damaged areas immediately by restoring the soil on slopes or channels to its finished grade, re -apply fertilizer and seed, and replacing the appropriate ECB material as needed. SEDIMENT TUBE INSTALLATION Stakes 2" x 2" wood stakes or Placed at 2' 1.25 #/ft Steel Post \� Minimum Spacing V 2.0' Spocin (Typical) Continuous Along Tube I SEDIMENT TUBE SPACING PLAN SYMBOL South Carolina Department of Health and Environmental Control SEDIMENT TUBES STANDARD DRAWING No. SC-05 PAGE 1 of 2 NOT TO SCALE FEBRUARY 2111, DATE SLOPE MAX. SEDIMENT TUBE SPACING LESS THAN 2% 150-FEET 2% 100-FEET 3% 75-FEET 4% 50-FEET 5% 40-FEET 6% 30-FEET GREATER THAN 6% 25-FEET SEDIMENT TUBES - GENERAL NOTES 1. Sediment tubes may be installed along contours, in drainage conveyance channels, and around inlets to help prevent off -site discharge of sediment -laden stormwater runoff. 2. Sediment tubes are elongated tubes of compacted geotextiles, curled excelsior wood, natural coconut fiber, or hardwood mulch. Straw, pine needle, and leaf mulch -filled sediment tubes are not permitted. 3. The outer netting of the sediment tube should consist of seamless, high -density polyethylene photodegradable materials treated with ultraviolet stabilizers or a seamless, high -density polyethylene non -degradable material. 4. Sediment tubes, when used as checks within channels, should range between 18-inches and 24-inches depending on channel dimensions. Diameters outside this range may be allowed where necessary when approved. 5. Curled excelsior wood, or natural coconut products that are rolled up to create a sediment tube are not allowed. 6. Sediment tubes should be staked using wooden stakes (2-inch X 2-inch) or steel posts (standard °U° or °T° sections with a minimum weight of 1.25 pounds per foot) at a minimum of 48-inches in length placed on 2-foot centers. 7. Install all sediment tubes to ensure that no gaps exist between the soil and the bottom of the tube. Manufacturer's recommendations should always be consulted before installation. 8. The ends of adjacent sediment tubes should be overlapped 6-inches to prevent flow and sediment from passing through the field joint. 9. Sediment tubes should not be stacked on top of one another, unless recommended by manufacturer. 10.Each sediment tube should be installed in a trench with a depth equal to 1 /5 the diameter of the sediment tube. 11.Sediment tubes should continue up the side slopes a minimum of 1-foot above the design flow depth of the channel. 12. Install stakes at a diagonal facing incoming runoff. SEDIMENT TUBES - INSPECTION & MAINTENANCE 1. The key to functional sediment tubes is weekly inspections, routine maintenance, and regular sediment removal. 2. Regular inspections of sediment tubes shall be conducted once every calendar week and, as recommended, within 24-hours after each rainfall even that produces 1/2-inch or more of precipitation. 3. Attention to sediment accumulations in front of the sediment tube is extremely important. Accumulated sediment should be continually monitored and removed when necessary. 4. Remove accumulated sediment when it reaches 1/3 the height of the sediment tube. 5. Removed sediment shall be placed in stockpile storage areas or spread thinly across disturbed area. Stabilize the removed sediment after it is relocated. 6. Large debris, trash, and leaves should be removed from in front of tubes when found. 7. If erosion causes the edges to fall to a height equal to or below the height of the sediment tube, repairs should be made immediately to prevent runoff from bypassing tube. 8. Sediment tubes should be removed after the contributing drainage area has been completely stabilized. Permanent vegetation should replace areas from which sediment tubes have been removed. 3 \ SEDIMENT TUBE DETAIL 5.0 REVISION DATE o o U ,C �wz � CER1 ''���/1111111111AAAAA`� Q N v0� O N N �y' J n ^' O o � �o �V^ O�� U°O00 ct 0 w W � � w d Q z FILE NAME: SSS.O.dwg REFERENCE FILE: ,SHEET I82I9-I090 BASE.dwg SSA 0 PROJECT NO. I82I9-I090 11111 DWG NO. 0191307-D23 1111 RUBBER POLYMER GASKET SEAL AND NON -SHRINK GROUT MANHOLE RING AND COVER CASTINGS SHALL BE OF THE SWIVEL TYPE. SEE APPROVED MATERIALS LI5T FOR ACCEPTABLE MANUFACTURERS AND MODELS NO -SHRINK GROUT BUTYL RING BOLTED cF TO MANHOLE 2'-0" F� 2 roc co 2� MANHOLE STEP (TYP.) JOINT BUTYL SEAL AND EXTERNAL WRAP (TYP) T 5�9 4" MAX. 7-9 I o 2'-0" MAX. m 6" OF #67 STONE O 000000 SECTION KEVI5ED DATE: 7/ 1 /04 1 /2G/ 17 SCALE: NONE DRAWN BY: JPH CHECKED BY: D5W APPROVED BY: D5W Ll�L7:i��Pl 5TAN DARD DETAIL CRO55 COUNTRY 5E1/VER M H DETAIL NOTES: I . MANHOLE TO CONFORM WITH A5TM C475 EXCEPT AS MODIFIED BELOW. 2. WALL REINFORCING TO BE A MINIMUM OF 0, 1 2 50, IN. PER LINEAR FOOT. EITHER TONGUE AND GROOVE OF JOINTS SHALL HAVE REINFORCING EQUAL IN AREA TO MINIMUM OF WALL SECTION. 3. ALL JOINTS SHALL CONFORM WITH A5TM C443. 4. STEPS SHALL BE COPOLYMER POLYPROPYLENE PLASTIC WITH 1/2" GRADE 60 STEEL REINFORCEMENT AND RESIST 1000 LB. PULLOUT TEST. 5. ALL PIPE OPENINGS TO BE NO GREATER THAN 3" LARGER THAN O.D. OF PIPE AND ADDITIONALLY REINFORCED WITH A MINIMUM OF 0.20 SO. IN. OF STEEL AT 90 DEGREES. PIPE TO BE CENTERED IN OPENINGS. G. ALL SURFACES SHALL BE SMOOTH EVEN TEXTURED WITH A MINIMUM OF HONEYCOMB, FINS AND OTHER IMPERFECTIONS. 7. MANHOLE BASE SHALL BE 3600 P.5.1. CONCRETE PLACED AGAINST SHAPED BANKS IN LIEU OF FORMS. 8. CARE MUST BE TAKEN TO FORM A SMOOTH FINISHED TROUGH FROM ENTRANCE PIPES TO EXIT PIPE, AND IN CURVED MANHOLES THE TROUGH MUST BE A SMOOTH CIRCULAR ARC TANGENT TO THE INSIDE WALLS OF THE PIPES AT THEIR ENDS. ALL CHANNELS TO BE 100% OF PIPE DIAMETER. 9. ALL MANHOLE RINGS SHALL BE BOLTED THROUGH MANHOLE AND/OR CONCRETE GRADE RING WITH 1/2" DIAMETER KWIK BOLT STUD ANCHOR SYSTEM. 10. MANHOLE GRADE SETTING SHALL BE AS FOLLOWS: A. FLUSH WITH GRADE IN PAVED AREAS B. 0. 1 O' ABOVE GRADE IN MOWED PLAZA AREAS WITHIN OR ADJACENT TO STREET RIGHT-OF-WAY. C. 2.0' ABOVE GRADE IN CP055-COUNTRY UTILITY RIGHTS -OF -WAY. D. A HEIGHT SPECIFIED BY THE WATER RESOURCES ENGINEER. 1 1. PENETRATING LIFTING HOLES SHALL BE PLUGGED WITH EXPANSION GROUT. 12. INFLOW DISHESPNSERTS SHALL BE INSTALLED ON ALL MANHOLES, 1 2-INCH SEWER MAINS OR LESS, WITH THE EXCEPTION TO CP055 COUNTRY MANHOLES. 13. FLOW CHANNELS MUST ALLOW FOR PLACEMENT, REMOVAL AND PASSAGE OF CITY OF MONROE CCTV EQUIPMENT. WATER RESOURCES DEPARTMENT CITY OF MONROE, NC 1 2.02.00 No 12 CROSS COUNTRY SEWER MANHOLE DETAIL 1 1/2" LETTERING 1 1/4" LETTERING \l C) V O O O n a�a O SF vvf �C) TFR RES�� z� � � O (2) OPEN PICKHOLE5 23 1/2" DIA 1 [597 MM] [25 MM] 21" DIA T�F2 3/4" [533 MM] [70 MM] COVER SECTION 5/8" [ 17 MMI tu- IVIIVIJ FRAME SECTION REVISED DATE: 3/3 1 /05 1 /2G/ 17 SCALE: NONE DRAWN BY: JPH CHECKED BY: D5W APPROVED BY: D5W (4) 1" (25mm) DIA HOLES ON 29 3/4" (756mm) BOLT CIRCLE. III [25 MM] 7 1 /2" r[191 MM] 7/8" [22 MM] BOTTOM VIEW (2 VENT HOLES) BOTTOM VIEW (NO VENT HOLES) NOTES: I . FRAME AND COVER SHALL BE CAST IRON, FREE OF SAND HOLES; NO PLUGGING PERMITTED. 2. TWO VENT HOLES SHALL BE PROVIDED EXCEPT WHERE PLANS REQUIRE NO VENT HOLES AND ONLY PICK HOLES. 3. FRAME SHALL INCLUDE FOUR DRILLED HOLES FOR EXPANSION ANCHORS THROUGH MANHOLE GONE. 4. METAL RINGS SHALL BE BOLTED INTO ADJUSTING RINGS WITH 1/2 " DIAMETER KWIK BOLT STUD ANCHOR 5U5TEM. HILTI BRAND OR APPROVED EQUAL. 5. CASTINGS FOR CR055 COUNTRY MANHOLES SHALL BE OF THE SWIVEL TYPE. SEE APPROVED MATERIALS LI5T FOR ACCEPTABLE MANUFACTURERS AND MODELS. STANDARD DETAIL STANDARD MANHOLE FRAME AND COVER DETAIL WATER RESOURCES DEPARTMENT CITY OF MONROE, NC No 1 2.06.0 1 NO. 12 STANDARD MANHOLE FRAME AND COVER DETAIL NOTES: 5TEEL VENT PIPE UNLESS OTHERWISE SPECIFIED SHALL BE SCHEDULE 40, FIVE INCH (51I) DIAMETER, 0 ;�— — 1 1 /8° - GRADE "15" WITH A MINIMUM YIELD STRENGTH OF 0 0 5" 5Ch 40 STEEL PIPE 35,000 P.S.I. O 0 0 A O EXTEND VENT 2'-0" ABOVE 100 YEAR FLOOD LINE. THE 5TEEL PIPE SHALL HAVE AN IN51DE COAL TAR I/4"ME5H5CREEN LINING 3/32 INCH MINIMUM THICKNESS WELD CONNECTION INACCORDANCE WITH AWWA C-203 OR A COAL TAR EPDXY LINING CONFORMING TO THAT REQUIRED FOR AERIAL CREEK CROSSING PIPE. A 10 3/4" GRAUT / \/ OUTSIDE SURFACE OF PIPE SHALL BE SAND OR GRIT 12'I BLASTED TO COMMERCIAL STANDARD AND HAVE ONE (1) COAT OF ZINC CHROMATE PRIMER APPLIED I/4"X2"STAINLESS STEEL 5TKAF52'-0"o.C. IN ACCORDANCE WITH FEDERAL SPECIFICATION — FROM BASE 2- 3/4" X 3" S.S. ANCHOR BOLTS 17-8GA. PER STRAP PIPE SHALL BE FURNISHED WITH TWO (2) EVENLY COPOLYMER POLYPROPYLENE PLASTIC APPLIED COATS OF RUST INHIBITING ENAMEL PAINT. REVISED DATE: 7/ 1 /04 SCALE: NONE DRAWN BY: EZ CHECKED BY: D5W APPROVED BY: D5W 1/2" GRADE GO 5TEEL REINFORCEMENT 1000 LB. PULLOUT TEST REPORT REQV ON EACH STEP. STANDARD DETAIL MANHOLE STEP DETAIL ('-3� MANHOLE STEP DETAIL 6.0 NOTES: MANHOLE STEPS SHALL BE MANUFACTURED IN ACCORDANCE WITH A5TM C-478 STANDARDS AND 05HA REGULATIONS. THIS STEP TO BE DRIVEN INTO TAPERED HOLES IN PRECAST MANHOLE SECTIONS. DO NOT USE AS A GROUTED IN STEP. WATER RESOURCES DEPARTMENT CITY OF MONROE, NC NO. 1 2.07.00 12 REVI5ED DATE: 7/ 1 /04 1 /2G/ 17 SCALE: NONE DRAWN BY: EZ CHECKED BY: D5W APPROVED BY: D5W 2"X2"X2" CONCRETE ANCHOR 5TAN DARD DETAIL VENTED MANHOLE DETAIL WATER RESOURCES DEPARTMENT CITY OF MONROE, NC \c). 1 2.08.00 12 4 VENTED MANHOLE DETAIL 6.0 NOTE: ALL CROSS COUNTRY MANHOLES TO HAVE SWIVEL LIDS IF NOT CALLED OUT TO BE WATERTIGHT. REVISION DATE Qa o� w o H H ¢ Q P w W � w Q z O 0 P u" � 0 a a IIIII FILE NAME: IIIIII IIII REFERENCE FILE: ,SHEET I82I9-I090 BASE.dwg SS60 PROJECT NO. I82I9-I090 DWG NO.01,1307—D23 FOR DIP < 20' BURY I I I 4" TOPSOIL IN OFF STREET RM/ VARIES CITY STREET STANDARDS IN STREET R/W 5ELECT BACKFILL NO ROCKS > 314 FOOT IN DIA. NO ORGANIC MATERIAL VARIES PLACEMENT IN I FOOT LIFTS COMPACTION TO 95% PROCTOR SELECT BACKFILL 2" NO ROCKS OR ORGANIC MATERIAL HAND PLACEMENT IN G INCH LIFTS COMPACTION TO 957. PROCTOR DIA. VARIE5 TYPE I FOR DIP BURY > 30' FOR PVC 5DR-35 3' < BURY < 1 2' I I I I 4TOPSOIL IN OFF STREET RlW " CITY 5TREET STANDARDS IN STREET KW VARIES 5ELECT BACKFILL NO ROCKS > 3/4 FOOT IN DIA. NO ORGANIC MATERIAL VARIES PLACEMENT IN I FOOT LIFTS COMPACTION TO 95% PROCTOR SELECT BACKFILL NO ROCK5 OR ORGANIC MATERIAL HAND PLACEMENT IN G-INCH LIFT5 1 2" COMPACTION TO 95% PROCTOR 2" DIA, ° ca�oo° cD�D,boD o 0 ooD0 oaog NO. 67 WASHED STONE 4 1 TYPE III REVISED DATE: 7/ 1 /04 1 /2G/ 17 SCALE: NONE DRAWN BY: JPH CHECKED BY: DSW APPROVED BY: DSW PROPOSE MA50NK AT BOTH END RESTRAINED JOINT SEWER RATED DUCTILE IRON PIPE (MUST EXTEND 5' MIN. BEYOND CASING BOTH ENDS) REVISED DATE: 7/ 1 /04 1 /2G/ 17 SCALE: NONE DRAWN BY: EZ CHECKED BY: DSW APPROVED BY: DSW j/\ FOR DIP BURY > 20' FOR PVC C900 DR-25 3' < BURY 20' I< [� 12 I 2 �[ I I I 4" TOPSOIL IN OFF STREET PIW VARIES CITY STREET STANDARDS IN 5TREET RW SELECT BACKFILL NO ROCKS > 3/4 FOOT IN DIA. NO ORGANIC MATERIAL VARIES PLACEMENT IN 1 2" LIFTS COMPACTION TO 95% PROCTOR SELECT BACKFILL 1 2" NO ROCK5 OR ORGANIC MATERIAL HAND PLACEMENT IN G-INCH LIFT5 COMPACTION TO 95% PROCTOR r- 1/3 PIPE DIA. °° ° q,o 0 NO. 67 WASHED STONE U o 4 I TYPE II NOTES: 1. A MINIMUM OF 1 2" FROM OUTSIDE DIAMENTER OF PIPE TO 51DE OF TRENCH MUST BE ALLOWED FOR COMPACTION OF FILL MATERIAL. 2. BACKFILUNG OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER THE PIPE IS LAID. 3. UNDER NO CIRCUMSTANCES SHALL WATER BE PERMITTED TO RISE IN UNBACKFILLED TRENCHES AFTER THE PIPE HAS BEEN PLACED. COMPACTION REQUIREMENTS SHALL BE ATTAINED BY THE USE OF MECHANICAL TAMPS ONLY. EACH AND EVERY LAYER OF BACKFILL SHALL BE PLACED LOOSE AND THOROUGHLY TAMPED INTO PLACE. 4. ALL PIPE GRADES SHALL BE AS SHOWN ON APPROVED PLANS OR AS DIRECTED BY ENGINEER. 5. ANY OVER EXCAVATION BELOW GRADE SHOWN SHALL BE BACKFILLED W/ NO. G7 STONE REGARDLESS OF TYPE OF BEDDING. G. WHERE ROCKY SOIL CONDITIONS ARE ENCOUNTERED REQUIRING BLASTING, TYPE III BEDDING SHALL BE USED REGARDLESS OF PIPE MATERIAL PER SPECIFICATIONS. 5TAN DARD DETAIL 5EWER PIPE BEDDING DETAIL 1 SEWER PIPE BEDDING DETAIL 6.1 5TAN DARD DETAIL CA51NG PIPE DETAIL CASING PIPE DETAIL WATER RESOURCES DEPARTMENT CITY OF MONROE, NC y0. 1 2.09.00 12 3TAI N LESS INSULATOR CEATG'OC WATER RESOURCES DEPARTMENT CITY OF MONROE, NC No 12.1 1.00 12 N 0 END CAP CONNECTION (TYP.) AI ILIA #G7 WASHED GRAVEL SEE DRAWING PAVEMENT 2 c� STEEL PIPE CA51NG SECTION COMMON BRICK MORTAR: I PART PORTLAND CEMENT 2 PART5 SAND REVISED DATE: 7/ 1 /04 112G/ 17 SCALE: NONE DRAWN BY: JPH CHECKED BY: D5W APPROVED BY: DSW SHOULDER / END CAP 8"� ENCASEMENT SPIDER SPACED EVERY G' 2'_0" CARRIER PIPE DOT 517E DOT THICKNESS RAILROAD SIZE RAILROAD THICKNESS G-INCH DIP 275" .250" G" .281" 8-INCH DIP I G" .250" 18" 3 1 2" 10-INCH DIP 18" .250" 20" 344" 2-INCH DIP 24" .250" 24" .40G" I G-INCH DIP 24" 250" 30" .4G9" 18-INCH DIP 30" .31 2" 30" .4G9" 20-INCH DIP 30 .375" 30, .5G2" 24-INCH DIP 30' 375" 30 .5G2" 30-INCH DIP 42" .500" 45" .750" 5TAN DARD DETAIL TYPICAL CA5ED CRO55ING DETAIL TYPICAL CASED CROSSING DETAIL 1 I/2" LETTERING 1/4" LETTERING (4) 1 " (25mm) DIA HOLES ON 29 3/4" (75Gmm) BOLT CIRCLE. 2) CAM LOCKS SEE DETAIL 23 1/2" DIA [597 MM] [25 MM] 20" DIA 2 3/4" [505 MM] 170 MM] t1l COVER SECTION 25 1/8" DIA IG38 MM] 23 1 1/ I G" DIA [G02 MM] 5/8, 22" DIA [ 17 MM] 1559 MM] 25 1 5/ I G" DIA [G59 MM] 33 114" DIA [545 MM] FRAME SECTION REVISED DATE: 3/3 1 /05 112G/ 17 SCALE: NONE DRAWN BY: JPH CHECKED BY: DSW APPROVED BY: DSW I" [25 MM] 7 112" r[191 MM] (2) CAM LOCKS BOTTOM VIEW 1 1/4" DIA 132 MM] II/1G" [ 8 MM] CAM LOCKS CAM LOCK DETAIL 1 1 /4" DIA 5/16" [32 MM] 5/8" 7/ [8 MM] M [ 7 MM] [22 MM] tj!e 3/ I G" 3/ 6" [5 MM] [5 MM] CAM HOLE AND GASKET GROOVE DETAIL 5TAN DARD DETAIL WATERTIGHT MANHOLE FRAME AND COVER DETAIL WATER RESOURCES DEPARTMENT CITY OF MONROE, NC No 12.10.00 12 (2) 55 ROLL PINS 1/2" DIA X 1 3/4" NOTES: 1. FRAME AND COVER SHALL BE CAST IRON, FREE OF SAND HOLES; NO PLUGGING PERMITTED. 2. CASTING SHALL BE COATED WITH COAL TAR EPDXY WHILE HOT. 3. FRAME SHALL INCLUDE FOUR DRILLED HOLES FOR EXPANSION ANCHORS THROUGH MANHOLE CONE. 4. SLIGHT VARIATION IN DIMENSIONS NOT CRITICAL TO INTERCHANGABILITY WILL BE ACCEPTABLE. 5. METAL RING5 SHALL BE BOLTED INTO ADJUSTING RING5 WITH 112 " DIAMETER KWIK BOLT STUD ANCHOR SYSTEM. WATER RESOURCES DEPARTMENT CITY OF MONROE, NC No 1 2.0(S.02 1 2 WATERTIGHT MANHOLE FRAME AND COVER DETAIL NOTE: ALL CROSS COUNTRY MANHOLES TO HAVE SWIVEL LIDS IF NOT CALLED OUT TO BE WATERTIGHT. REVISION DATE 0 w o ol Ln y N O b U a) C) O _ U ,C s , w Z CERA W W W � d � Q _z ' �O U u u �0�4 P 0 u W 0P�� � z O a Q/'] IIIII FILE NAME: IIIIII IIII REFERENCE FILE: ,SHEET I82I9-I090 BASE.dwg SS61 PROJECT NO. I82I9-I090 DWG NO.01,1307-D23 a CORE BRILL PIPE OPENING GASKET SEAL, PRESS IN EXISTING MANHOLE WALL ' '.. �'�' SEAL GASKET CORP., OR i APPRO4ED EQUAL NOTE: DRILL OUT ENTRANCE I HOLE IN MANHOLE BARREL, BASE, AND BENCH FOR REQUIRED I I PIPE CLEARANCE. CUT REINFORCING WIRE MESH OR BARS IN CENTER OF CUT HOLE 1 AND BEND OUTWARD. I WATER PLUG MATERIAL SANITARY PRECO OR EQUAL SEWER •;rr 4' PRECAST CONCRETE MANHOLE WALL # REVISED DATE: 7/ 1 7/ 1 7 5TAN DARD DETAIL WATER RESOURCES DEPARTMENT SCALE: NONE CITY OF MONROE, NC DRAWN BY: RKS MANHOLE CONNECTION DETAIL CHECKED BY: RKS NIo 1 2 1 4.00 NO. 12 APPROVED BY: RKS . MANHOLE CONNECTION DETAIL 1/2" m KWIK BOLT STUD ANCHOR SYSTEM CA5T IRON FRAME X COVER SEE STD DETAILS UTYL SEAL CI RINGS AND GRADE RINGS (fyp.) N 2E CONIC. GRADE G5 FOR ADJUSTMENT OF 7FLUSH MANHOLES MIN. T CN I G" O.C. tiF STEP BUM SEAL �4" MIN. DIP 3�r-n-, 4'-O" uJ N a 1 m DIP , ' r 3 - #G REBAR5 DOWELED $ EPDXIED INTO MH BASE POUR 3' X 3' CONCRETE FOOTING G" THICK TO SUPPORT DROP STRUCTURE REVISED DATE: 7/ 1 /04 1 /26/ 17 SCALE: NONE DRAWN BY: PH CHECKED BY: DSW APPROVED BY: DSW NOTES: I . MANHOLE TO CONFORM WITH A5TM C475 EXCEPT AS MODIFIED BELOW. 2. WALL REINFORCING TO BE A MINIMUM OF O. 12 SO. IN. PER LINEAR FOOT. EITHER TONGUE AND GROOVE OF JOINTS SHALL HAVE REINFORCING EQUAL IN AREA TO MINIMUM OF WALL SECTION. 3. ALL JOINTS SHALL CONFORM WITH ASTM C443. 4. STEPS SHALL BE COPOLYMER POLYPROPYLENE PLASTIC WITH 1/2" GRADE GO STEEL REINFORCEMENT AND RESIST I COO LB. PULLOUT TEST. 5. ALL PIPE OPENINGS TO BE NO GREATER THAN 3" LARGER THAN O.D. OF PIPE AND ADDITIONALLY REINFORCED WITH A MINIMUM OF 0.20 50. IN. OF STEEL AT 90 DEGREES. PIPE TO BE CENTERED IN OPENINGS. G. ALL SURFACES SHALL BE SMOOTH EVEN TEXTURED WITH A MINIMUM OF HONEYCOMB, FIN5 AND OTHER IMPERFECTIONS. 7. MANHOLE BASE SHALL BE 3GOO P.5.1. CONCRETE PLACED AGAINST SHAPED 13ANK5 IN LIEU OF FORMS. 9' JT. D.I.P. OR D.I.P. TO UNDI5TURBED GRO� — SEAL PIPE PER ASTM C-923 OYP.) ALL FITTING AND PIPE TO BE SEWER RATED DIP RESTRAINED JOINT 0 SECTION A -A STANDARD DETAIL OUT5IDE MANHOLE DROP DETAIL OUTSIDE MANHOLE DROP DETAIL 8. CARE MUST BE TAKEN TO FORM A SMOOTH FINISHED TROUGH FROM ENTRANCE PIPES TO EXIT PIPE, AND IN CURVED MANHOLES THE TROUGH MUST BE A SMOOTH CIRCULAR ARC TANGENT TO THE INSIDE WALLS OF THE PIPES AT THEIR ENDS. 9. ALL MANHOLE RINGS SHALL BE BOLTED INTO MANHOLE THRU CONCRETE GRADE RING WITH 1 /2" DIAMETER KWIK BOLT STUD ANCHOR SYSTEM. 10. MANHOLE GRADE SETTING SHALL BE AS FOLLOWS: A. FLUSH WITH GRADE IN PAVED AREAS B. 0. 1 O' ABOVE GRADE IN MOWED PLAZA AREAS WITHIN OR ADJACENT TO STREET RIGHT-OF-WAY. C. 2.0' ABOVE GRADE IN CROSS-COUNTRY UTILITY RIGHTS -OF -WAY. D. A HEIGHT SPECIFIED BY THE WATER RESOURCES ENGINEER. 1 1. PENETRATING LIFTING HOLES SHALL BE PLUGGED WITH EXPANSION GROUT. 12. THE SLOPE OF THE OUTSIDE DROP TROUGH SHALL BE I %. 13. OUTSIDE DROP SHALL NOT PENETRATE MORE THAN 3" 14. STRAIGHT SECTION WITH STEPS SHALL BE OPPOSITE OUTSIDE DROP SECTION CONE SECTION AS SHOWN. WATER RESOURCES DEPARTMENT CITY OF MONROE, NC N'LE o 1 2.03.00 12 REVISION DATE W W Ca U VAAAAAAI l l l l l IIIL�LT,7i J0 - QS Q CN sa� d Q d dC) IIIII FILE NAME: IIIIII IIII REFERENCE FILE: ,SHEET I82I9-I090 BASE.dwg SS62 PROJECT NO. I82I9-I090 DWG NO.01,1307-D23