Loading...
HomeMy WebLinkAbout20190175 Ver 2_B4427_Beaufort 6 water main permit drawing_20191004ASHLEY McMULLAN WOOLARD DB 1761 PG 885 DB 933 PG 650 DB 817 PG 897DB 1734 PG 894 JIMMY C. HARDISON M.U. HODGES, et ux JIMMY C. HARDISON PC "A" SLIDE 68PROPERTY LI NE RUNS ALONG MOYE'S BEAVER DAM SWAMPEIP 100.00'100.00'EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W MOYE' S BE AVE R DAM S WAMP P ROP E RT Y LI NE RUNS AL ONG-30 -40 -WL1- STA. 0+87.50 PROP. 8"X6" REDUCER -WL1- STA. 0+11.20 PROP. 6" GATE VALVE -L- STA. 20+81.87, 17.35' LT -WL1- STA. 0+00.00 = WATERLINE WITH A 6" TRANSITION COUPLING BEGIN: CONNECT TO EXIST. 6" PVC -L- STA. 26+94.40, 14.43' LT -WL1- STA. 6+24.80 = WITH A 6" TRANSITION COUPLING END: CONNECT TO EXIST. 6" PVC WATERLINE -WL1- STA. 5+39.96 PROP. 8"X6" REDUCER -WL1- STA. 6+16.57 PROP. 6" GATE VALVE 6" PVC WATERLINE REMOVE 33.0' OF IS INSTALLED AFTER NEW WATERLINE ABANDON 6" GATE VALVE 6" PVC WATERLINE ABANDON 218.0' OF 29.36' LT -L- STA. 21+13.66, -WL1- STA. 0+36.76 = 17.45' LT -L- STA. 21+01.87, -WL1- STA. 0+20.00 = 32.12' LT -L- STA. 26+61.35, -WL1- STA. 5+84.45 = PROP. 6" DIP WATERLINE 14.33' LT -L- STA. 26+79.40, -WL1- STA. 6+09.80 = 6" PVC WATERLINE REMOVE 29.0' OF IS INSTALLED AFTER NEW WATERLINE ABANDON 6" GATE VALVE 6" PVC WATERLINE REMOVE 125.0' OF 6" PVC WATERLINE ABANDON 214.0' OF SEE NOTE 5 WATERLINE PROP. 6" DIP 8/17/99SHEET NO.PROJECT REFERENCE NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: TRANSPORTATION DEPARTMENT OF NORTH CAROLINA PLANS ONLY UTILITY CONSTRUCTION REVISED: UTILITIES ENGINEERING SEC. FAX:(919)250-4151 PHONE:(919)707-6690 MNG SRM MKS DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED 0'50'100'25'50' PLANS UTILITY CONSTRUCTION SRM F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F TB 2GI TB 2GI 0401 0402 0403 5 SY GEOTEXTILE 1 TONS CLASS 'B' RIP RAP -L- STA. 23+05.00 LT/RT BEGIN SHOULDER BERM GUTTER -L- STA. 23+31.94 LT/RT END SHOULDER BERM GUTTER 15" RCP-III 15" RCP-V -BL- 4-BL- 3 NCDOT GPS B4427-2 WOODS WOODS WOODS WOODS WOODS WOODS WOODS SR 1422 (MARKET STREET EXT) SR 1422 (MARKET STREET EXT) 22' BST 22' BST PMAWS GIB PM AWS GIB 100 101 IREVISIONS 8/17/99SHEET NO.PROJECT REFERENCE NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: TRANSPORTATION DEPARTMENT OF NORTH CAROLINA PLANS ONLY UTILITY CONSTRUCTION REVISED: UTILITIES ENGINEERING SEC. FAX:(919)250-4151 PHONE:(919)707-6690 MNG SRM MKS DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED -20 -10 0+00 1+00 2+00 3+00 4+00 5+00 0 10 20 30 40 40 30 20 10 0 -10 -20 -30 -40 0'50'100'25'50' PLANS UTILITY CONSTRUCTION 17BP.2.R.89 SRM 6+00 0'50'100'25'50' PROFILE (HORIZONTAL) 0'10'20'5'10' PROFILE (VERTICAL) AS APPROVED BY THE ENGINEER. SHALL BE DISCHARGED AND DISCHARGED WATER SHALL BE DECHLORINATED TEMPORARY BLOWOFF TO TEST THE WATERLINE. SUPER-CHLORINATED WATER CONTRACTOR SHALL PROVIDE END CAP WITH 2" IPT CONNECTOR FOR 5. ALL DUCTILE IRON PIPE SHALL BE RESTRAINED.4. THE REQUIRED RESTRAINED LENGTH. INSTALL BELL AND HARNESS RESTRAINT ON THE NEXT PIPE JOINT PAST RESTRAINED LENGTH DOESN'T END AT A PIPE JOINT, CONTRACTOR SHALL RESTRAINED JOINT DETAIL ON SHEET UC-3A. IF THE REQUIRED EACH PIPE JOINT FOR A MINIMUM LENGTH AS SPECIFIED IN THE EXCAVATING AND INSTALLING A BELL AND HARNESS RESTRAINT AROUND CONTRACTOR SHALL RESTRAIN THE EXISTING WATERLINE BY 3. RESTRAINED JOINT LENGTHS. REFER TO THE RESTRAINED JOINT DETAIL ON SHEET UC-3A FOR 2. LEADING UP TO CONNECTION. WATERLINE PRIOR TO MAKING CONNECTION AND ADJUST PIPE AS NEEDED CONTRACTOR SHALL VERIFY THE LOCATION AND DEPTH OF THE EXISTING LOCATIONS IS ASSUMED TO BE 3 FEET BELOW EXISTING GRADE. ELEVATION OF EXISTING 6" WATERLINE AT WATERLINE TIE-IN 1. NOTES: 100.00' 50.00' UC-4 (PERMIT) T T T T 25.00'WETLANDS FOR OPEN CUT MINIMUM DISTANCE OFF OF THE WETLANDS FOR OPEN CUT MINIMUM DISTANCE OFF OF THE EXIT) STAGING AREA (100' X 50') TEMPORARY HDD ENTRY (PIPE STAGING AREA (50' X 50') TEMPORARY HDD EXIT (PIPE ENTRY) AREA WETLANDS FOR HDD STAGING MINIMUM DISTANCE OFF OF THE STA. 0+91 STA. 5+39 15.00' 10.00' 50.00' 15.00' 10.00' W1 (TEMP.) WETLAND IMPACT = 0.02 AC/1038 SF W2 (TEMP.) WETLAND IMPACT = 0.04 AC/1526 SF DENOTES WETLAND IMPACTS GV GV0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00AS APPROVED BY THE ENGINEER. SHALL BE DISCHARGED AND DISCHARGED WATER SHALL BE DECHLORINATED TEMPORARY BLOWOFF TO TEST THE WATERLINE. SUPER-CHLORINATED WATER CONTRACTOR SHALL PROVIDE END CAP WITH 2" IPT CONNECTOR FOR 5. ALL DUCTILE IRON PIPE SHALL BE RESTRAINED.4. THE REQUIRED RESTRAINED LENGTH. INSTALL BELL AND HARNESS RESTRAINT ON THE NEXT PIPE JOINT PAST RESTRAINED LENGTH DOESN'T END AT A PIPE JOINT, CONTRACTOR SHALL RESTRAINED JOINT DETAIL ON SHEET UC-3A. IF THE REQUIRED EACH PIPE JOINT FOR A MINIMUM LENGTH AS SPECIFIED IN THE EXCAVATING AND INSTALLING A BELL AND HARNESS RESTRAINT AROUND CONTRACTOR SHALL RESTRAIN THE EXISTING WATERLINE BY 3. RESTRAINED JOINT LENGTHS. REFER TO THE RESTRAINED JOINT DETAIL ON SHEET UC-3A FOR 2. LEADING UP TO CONNECTION. WATERLINE PRIOR TO MAKING CONNECTION AND ADJUST PIPE AS NEEDED CONTRACTOR SHALL VERIFY THE LOCATION AND DEPTH OF THE EXISTING LOCATIONS IS ASSUMED TO BE 3 FEET BELOW EXISTING GRADE. ELEVATION OF EXISTING 6" WATERLINE AT WATERLINE TIE-IN 1. NOTES: 0+00 1+00 2+00 3+00 4+00 5+00 6+00 0 0 10 20 30 40 GV DEPTH (TYP.) 3' MIN. BURIAL WATERLINE HDPE DR II PROP. 8" WATERLINE PROP. 6" DIP PIPE HORIZONTAL 117.00' -WL1- STA. 0+91.65 -WL1- STA. 5+39.24 HORIZONTAL DIRECTIONAL DRILL LIMITS GRADE EXIST. WATERLINE PROP. 6" DIP GV WATERLINE HDPE DR II PROP. 8"15.00'R=600' R=600' -WL1- STA. 0+00.00 WATERLINE EXIST. 6" PVC DEPTH (TYP.) 3' MIN. BURIAL -WL1- STA. 6+16.57 GATE VALVE PROP. 6" -WL1- STA. 6+24.80 WATERLINE EXIST. 6" PVC -WL1- STA. 6+09.80 PROP. 6" -WL1- STA. 5+84.45 PROP. 6" -WL1- STA. 0+11.20 GATE VALVE PROP. 6" -WL1- STA. 0+20.00 PROP. 6" -WL1- STA. 0+36.76 PROP. 6" EL. 6.60 -WL1- PT STA. 2+58.21 END VERTICAL CURVE EL. 19.70 -WL1- PC STA. 1+33.15 BEGIN VERTICAL CURVE EL. 6.60 -WL1- PC STA. 3+75.21 BEGIN VERTICAL CURVE EL. 19.70 -WL1- PT STA. 4+99.96 END VERTICAL CURVE -WL1- STA. 0+87.50 IN DETAIL SHEET UC-3B SEE DIP/HDPE TRANSITION PROP 8"X6" REDUCER -WL1- 5+39.96 IN DETAIL SHEET UC-3B SEE DIP/HDPE TRANSITION PROP 8"X6" REDUCER