Loading...
HomeMy WebLinkAboutWQ0041115_Application (FTSE)_20191003Permit Number W00041115 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Permitted Flow Facility Facility Name Stump Sound Elementary School Sewer Location Address Owner Central Files. APS _ SWP 8/20/2019 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County Onslow Facility Contact Affiliation Owner Name Owner Type Pluns LLC Non -Government Owner Affiliation Maurice W. Gallarda PE 150 Turtle Creek Blvd Dates/Events Dallas TX 75207 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective 8/19/2019 Ak RECEIVED/NCDENR/DWR AUG 19 2019 ENGINEERS • SURVEYORS • PLANNERS VIA EMAIL AND MAIL TO: Mr. Dean Hunkele NCDENR - DWR 127 Cardinal Dr. Ext. Wilmington, NC 28405-3845 WE ARE SENDING YOU: Water Quality Regional Operations Section Wilmington Regional Office LETTER OF TRANSMITTAL DATE: August 16, 2019 REF: Stump Sound Elementary School Onslow County, NC Fast Track Sewer Application One (1) original and One (1) copy of the Fast Track Sewer Application; One (1) Check No. 39555 in the amount of $480.00 for the application fee; One (1) Flow Tracking/Acceptance Form; One (1) copy of portion of the USGS map; and One (1) copy of Water and Sewer Plans (Sheet C103). DELIVERY VIA: O Regular Mail ❑ Hand ❑ Federal Express ❑ UPS Overnight ❑ UPS Ground ❑ Other THESE ARE TRANSMITTED AS CHECKED BELOW: ❑x For Approval ❑ As Requested ❑ For Review and Comment ❑ For Your Use ❑ For Bids Due ❑ Other COMMENTS: Dean, Onslow County is proposing to build new elementary school. We have designed pump stab and force main to tie to Pluris Sewer. Let me know if you have anv auestions. , _ Timothy M! S�ew�rt, P.E. Copies To: t ec: Mr. Randy Baker (LOT only) Mr. Steve Myers (LOT only) Mr. Randy Hoffer (w/enclosures) TMS/djh CF (P), LAM 306 New QifrdQnCG0mtr0#.&CP100H kmWeiAckk0&ylYh dAOil- 41966�010) 455-2414 C1.2019.TMS.LOT.Hunkele.SSES.SewerAPP.08f5iINn License Number F-0108 I www.parkerjacksonville.com State of North Carolina Department of Environmental Quality DWR Division of Water Resources """I 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources PTA 04-16 & SUPPORTING DOCUMENTATION Application Number: W 660 -1 (I 1 S (to be wmple(ed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: PLURIS. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ® Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: RANDY HOFFER per 15A NCAC 02T 0106(b) Title: NC Regional Manager 4. Applicant's mailing address: 1095 Hwy 210 City: Sneads Ferry State: NC Zip: 28460-_ 5. Applicant's contact information: Phone number: 910 327-2880 Email Address: rhoffer@nlurisusa.com II. PROJECT INFORMATION: I. Project name: STUMP SOUND ELEMENTARY SCHOOL 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00_ and issued date: If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: ONSLOW 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.51610 Longitude:-77.48940 5. Parcel ID (if applicable): 020312 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: TIMOTHY M. STEWART License Number: 14575 Firm: Parker & Associates- Inc. Mailing address: 306 New Bridge Street City: Jacksonville State: NC Zip: 28540-_ Phone number: (910) 455-2414 Email Address: office@parkerjacksonvillc.com 1V. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: PLURIS NORTH TOPSAIL Owner Name: PLURIS. LLC Permit Number: W00005849 V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W00035171 Downstream (Receiving) Sewer Size: 12 inch System Wide Collection System Permit NumberO (if applicable : WQCS Owner Name(s): PLURIS, LLC FORM: FTA 04-16 Page I of VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ❑N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Propedy Owners' Association, has an Operational Agreement (FORM: HOA) been attached? []Yes []No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ® School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial _ % Industrial (See I SA NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Hasa flow reduction been approved under 15A NCAC 02T 0114(f)? ❑ Yes ® No ➢ If yes, provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 021.01140 Daily Design Flow °'s No, of Units Flow SCHOOL 12 gal/Student 848 10,176 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total I 10,176 GPD a See 15A NCAC 02T 0114() (d) (e)(I) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 10` GPD (per 15A NCAC 02T 0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 836 PVC ➢ Section II & M of the MDC for Permitting of Gravity Sewers contains information related to design criteria D Section Ill contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T.0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 1 2. Approximate Coordinates (Decimal Degrees): Latitude: 4.515° Longitude:-77.49060 3. Design flow of the pump station: 0.25 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 176 gallons per minute at 128 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6" 5550 PVC 6" 240 DI 8" 1100 HDPE 6. Power reliability in accordance with 15A NCAC 02T 0305(h)(I ): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ® Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(t)): Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) D 15A NCAC 02T.0305(f) contains minimum qe nmtinne ihm o6ou 6e --. ,:A -A r . ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevatioo and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet An basement 10 feet' Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ I SA NCAC 02T 0305(e) contains alternatives where separations in 2T.0305 cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weboa e D If noncompliance with 02T.0305(1) or (e), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [-]No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet D No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B 0200? ®Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with I SA NCAC 02T.0I05(c)(61(additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0 1 05(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?' Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and Inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with ISA NCAC 02T, the Minimum Desiap Criteria for the Petmittine of Pump Stations and Force Mains (latest version), and the Gravil Sewer minimum Desipn_Criteria Latest version( as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. AAp ti roval of the request is required prior to submittal of the Fast Track Application and sunnn_ rting documents. 2. Professional Engineer's Certification: Timothy M. Stewart, P.E. attest that this application for (Professional Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, ns well as civil penalties up to $25,000 per violation. A s s North Carolina Professional Engineer's seal, signature, and d 3. Applicam's Certification per ISA NCAC 02T .0I06(b): Randy Hoffer, Regional Manager _attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes I43-215.6A and 143-215_6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: _ _ _ Date: FORM: FTA 04-16 page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: ONSLOW COUNTY SCHOOL Project Name for which flow is being requested: Stump Sound Elementart School More than one FTSE nary be required for a shtgle project if the owner of the WWTP is not responsible for all punip stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Pluris, LLC b. WWTP Facility Permit #: WQ0005849 All flatus are in MGD c. WWTP facility's permitted flow 1.542 d. Estimated obligated flow not yet tributary to the WWTP 0.406840 e. WWTP facility's actual avg. flow 0.581256 f. Total flow for this specific request 0.010176 g. Total actual and obligated flows to the facility 0.998238 h. Percent of permitted flow used 65% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Finn Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Finn / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MUD MUD Flow, MUD MUD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Sneads Ferry South Sewer Basin Downstream Permit Number: WQ0034485 Page I of 6 FTSE 10-18 III. Certification Statement: I Randy Hoffer certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature Title of Signing Official Page 2 of 6 FTSE 10-18 Ili 14 Sum OOP \ •• / S S Fa zos I i Rovntl',. k sb -fro I E" R 1, 10 EIpM i ScHotK �� 51T� •� • ej 0 zs P 15b1 • irvTER1 ..t OP—GEOLOGICSV nV EV,ves.G«. A �69 270--'E, II 77°30' 747500 METERS '72 ROAD CLASSIFICATION Produced by the United States Geological Survey mary highway, 'd surface Light -duty road, hard or improved Topography compiled byplanetable surve s 1950 and 1952 Plammetry derived from lmaggerryytaken 19Y97 -....-....-.- surface..-.. - andothersources Survey control current as of 1952 -ondary highway, d surface. __. -. Unimproved road-.._—______1000-metergrid: -----2 North American Datum of 1983 (NAD 83). Projection and Universal Transverse Mercator, zone l8 00-meter ticks: North Carolina Coordinate Svetem of 1 one X,, a ou of s9efts FemiY qKp FbLk.SfoA( LLSCS 1"Afs MN,,._ 1 Googie Maps 34030'58.0"N 77°29'21.8"W Google f Vqe Rd G—"u QRd u 4 I a off° e 6 p.µ,M a"Qa, Map data 02019 500 ft An& 8/20/2019 Hunkele, Dean From: Tim Stewart <office@ parkerjacksonvil le.com > Sent: Wednesday, October 2, 2019 4:23 PM To: Hunkele, Dean Cc: Randy Hoffer Subject: Re: [External] RE: Pending WQ0041115 Stump Sound Elem pump station Dean, I reviewed the pump system model and also talked to Randy Hoffer. To downsize the pumps for a 4" force main out to the road would still require the same pump, just slightly less horsepower. Therefore, I think it is best to leave the design as it is. Let me know if you need anything else. Thanks. -Tim Timothv M. Stewart, PE / dih Parker & Associates, Inc Jacksonville NC, 28540 Firm License Number F-0108 910-455-2414 - Office Parkedacksonville.com ATk On 9/25/2019 2:54 PM, Hunkele, Dean wrote: Hey Tim, You only need to meet scour in the FM leaving your project to the point of connection with a larger main, thus sounds like this is being way over designed. For example, if your project only needs a 4" out to the road to meet its needs and you upsize to a 6" on the main roads for the utility, then scour only applies to the 4" at the point of connection to the 6". Since it's the only user of the 6" initially, then you just need to point out there will be inadequate scour in the 6" upon completion. It is up to the system owner/utility to manage flows in that larger line to avoid issues of deposition & septicity via flushing ports at key locations especially upstream of large bores until adequate future connections & flow are added. Let me know if you would like to look at redesigning the on -site system. Dean Hunkele Environmental Specialist II Water Quality Regional Operations Section Division of Water Resources Department of Environmental Quality 910.796.7215 Reception Desk 910.796.7380 Direct 910.350.2004 Fax Dean. Hunkele(o)ncdenr.gov Wilmington Regional Office 127 Cardinal Drive Ext Wilmington, NC 28405 http://deg.nc.gov/contact/regional-offices/wilmington Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties The goal of the Fast Track sewer permit program is to issue a permit in no more than 30 business days from receipt of a complete application and if no additional information has to be requested upon full review. Please use the Department's Permit Application Tracker to determine the official application receipt date to allow you to estimate a date for issuance and find the reviewer's name. Once issued, the record stays on the site for 30 days. For previously issued sewer permit info or to check on sewer certification receipt status, please use the Division's Sewer Extension Permit Tracker. Using the Issue Date on top of the Engineer Certification Form is best way to ensure getting what you want especially for multi -version permits; using today's date only gives info on the latest permit version. Confirmation using this method will replace letters and emails; it is recommended that confirmation be printed and/or saved. Links to both trackers can be found on the sewer permitting site here: https://deg.nc.gov/about/divisions/water- resou rces/water-resou rces-permits/pe res/co llectlon-systems-pe rm Its Subscribe to Collection System Updates listserve to receive automatic alerts for changes to applications, policies, regulations, etc. From: Parker & Associates [mailto:office@parkeriacksonville.com] Sent: Wednesday, September 25, 2019 11:59 AM To: Randy Hoffer <rhoffer@plurisusa.com> Cc: Hunkele, Dean <dean.hunkele@ncdenr.gov> Subject: [External] RE: Pending WQ0041115 Stump Sound Elem pump station Randy/Dean, The Pump Station was not set up to be a Regional Station. It will serve the school only. However, we did upsize the Force Main (as requested by Pluris), so other possible future developments along Folkstone Road or Tar Landing Road could tie to it. Due to upsizing the Force Main, we increased the GPM of the Pumps, so we would get 2 feet per second velocity in the Force main. Let me know if you have any other questions. Thanks, Tim Timothy m. Stewart, PE/brs Parker & Associates, Inc 306 New Bridge Street Jacksonville NC, 28540 Firm License Number F-0108 910-455-2414 - Office Pa rkerJacksonvi I le.com On 9/24/2019 2:56 PM, Randy Hoffer wrote: Tim, Please see Dean's email below. Randy Hoffer NC Reaional Manaaer ��PLU R I S Pluris Holdings LLC M 910-327-2880 F 910-327-0374 0 1095 Hwa 310 Sneads Ferry. NC 38460 ! 1111 -ncui ..uhlca a� the I'luri11dII1 11 i:ul dndmnicr. Click ro read full disclaimer_ From: Hunkele, Dean[mailto:dean.hunkele@ncdenr.gov] Sent: Tuesday, September 24, 2019 2:50 PM To: Randy Hoffer; Kaarin Williams Subject: RE: [External] RE: Pending WQ0041115 Stump Sound Elem pump station So do you want me to condition the permit that it has to be upgraded by you with the next tributary flow permit or do you want OCS to pay for it now? Needs to be considered in the design and installation now though. The station is sited quite deep in the parcel close to the school best I can tell from the limited drawing I got; thus seems limited in its ability to be regional. Let me know and perhaps ask Tim Stewart. Dean Hunkele Environmental Specialist II Water Quality Regional Operations Section Division of Water Resources Department of Environmental Quality 3 910.796.7215 Reception Desk 910.796.7380 Direct 910.3S0.2004 Fax Dean.Hunkele@ncdenr.gov Wilmington Regional Office 127 Cardinal Drive Ext Wilmington, NC 28405 http://deg. nc,goy/contact/regiona I-offices/wi Im i ngton Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties The goal of the Fast Track sewer permit program is to issue a permit in no more than 30 business days from receipt of a complete application and if no additional information has to be requested upon full review. Please use the Department's Permit Application Tracker to determine the official application receipt date to allow you to estimate a date for issuance and find the reviewer's name. Once issued, the record stays on the site for 30 days. For previously issued sewer permit info or to check on sewer certification receipt status, please use the Division's Sewer Extension Permit Tracker. Using the Issue Date on top of the Engineer Certification Form is best way to ensure getting what you want especially for multi -version permits; using today's date only gives info on the latest permit version. Confirmation using this method will replace letters and emails; it is recommended that confirmation be printed and/or saved. Links to both trackers can be found on the sewer permitting site here: https://deg.nc.gov/about!divisions/water-resources/water-resources-permits/peres/collection- systems-permits Subscribe to Collection System Updates listserve to receive automatic alerts for changes to applications, policies, regulations, etc. From: Randy Hoffer [mailto:rhoffer@plurisusa.com] Sent: Tuesday, September 24, 2019 2:37 PM To: Hunkele, Dean <dean.hunkele@ncdenr.Rov>; Kaarin Williams <kwilliams(n@plurisusa.com> Subject: [External] RE: Pending WQ0041115 Stump Sound Elem pump station There was talk of Jack Carlisle using this station for 50 acres that is next to the pump station but I'm not aware of any deal. Randy Hoffer NC Regional Manager �PLURIS Pluris Holdings LLC' Y1 910-327-2880 F 910-327-0374 O 109i Hwy 210 Sneads Ferrv, NC 28460 I hi, e-m:nl n,uhiad io iha 11111 1, l Inldin•,. avail di,d:nnrr Click to read Full di,clalmer. From: Hunkele, Dean[mailto:dean.hunkeleCcbncdenr.gov] Sent: Tuesday, September 24, 2019 12:25 PM To: Randy Hoffer; Kaarin Williams Subject: Pending WQ0041115 Stump Sound Elem pump station Importance: High Randy, The app came in listing a portable generator connection, but this 176-gpm pump station is too large to only serve the school which is slated to be under 15K gpd. Thus, shouldn't this station have a permanent one or pump since it will be more of a regional station and serve more later? Dean Hunkele Environmental Specialist II Water Quality Regional Operations Section Division of Water Resources Department of Environmental Quality 910.796.7215 Reception Desk 910.796.7380 Direct 910.350.2004 Fax Dean.Hunkele@ncdenr.gov Wilmington Regional Office 127 Cardinal Drive Ext Wilmington, NC 28405 http://deg.nc.gov/contactZregional-offices/wilmington Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties The goal of the Fast Track sewer permit program is to issue a permit in no more than 30 business days from receipt of a complete application and if no additional information has to be requested upon full review. Please use the Department's Permit Application Tracker to determine the official application receipt date to allow you to estimate a date for issuance and find the reviewer's name. Once issued, the record stays on the site for 30 days. For previously issued sewer permit info or to check on sewer certification receipt status, please use the Division's Sewer Extension Permit Tracker. Using the Issue Date on top of the Engineer Certification Form is best way to ensure getting what you want especially for multi -version permits; using today's date only gives info on the latest permit version. Confirmation using this method will replace letters and emails; it is recommended that confirmation be printed and/or saved. Links to both trackers can be found on the sewer permitting site here: https:ffdeg,nGQoylabout/divisions/water-resources/water-resources-permitsfperes/collection- systems-permits Subscribe to Collection System Updates listserve to receive automatic alerts for changes to applications, policies, regulations, etc.