Subject: Compliance Inspection
Permit No. WQ0002428
Mount Vernon Hatchery Facility
Wastewater Irrigation System
Chatham County
Staff of the NC Division of Water Resources (DWR), Water Quality Regional Operations
Section (WQROS) inspected Mountaire Farms' Mount Vernon Hatchery Wastewater
Treatment and Surface Irrigation System Permit No. WQ0002428 on September 24, 2019. 1
would like to thank you for your assistance during the inspection.
Doug Goodwin is currently designated as ORC and Robert Jackson is designated as Back-up
ORC.
The permit does not require metering water flowing to the lagoon. Wastewater flows to the
lagoon from four separate pipes. Three are "process water" and one is domestic. The
domestic wastewater flows through septic tank and a Cl tablet chlorinator. The tank is
pumped four times each year.
The flow rate reported on NDMR's is the total of the water pumped to the sprayfields. About
30,000 gallons of wastewater per week is being hauled to this facility from the other hatchery.
Application rates have risen to 11-18 inches per year which is within the 25.71" permitted.
The residual chlorine meter always reads 0.03. Staff intend to determine if it is working by
running more highly chlorinated water through it and looking for a response.
Levels in aeration lagoons are controlled by set overflow pipes which send flows to storage
lagoon. The level gauges appeared properly installed and easily legible.
Bob Branch profiled the lagoons for residuals. Lagoon 1 and 2 will be dredged in 2019 or
2020. One field was fertilized in 2019. The third cutting of hay is underway.
N'if tfr C;IrU11s)i DI' Iwo tnu•rit of hNirurtnU'r t ,f Qu r it 0i';Nion of 4Natvr Rcxrur'ces
� 1 + It,,feir411 fit' irnfti rl U,:e StiOU Br.e• d't' 11 7rI R-11:•iyi�L of Its Camlinm _'7609
aw•�M•�r E,.mm-," w.•, d__' 1719.701.4200
One aerator broke on Saturday. It will be repaired in 2 weeks. The aerator panel was
xeplaced4n401-$. One sprayfield pump was replaced since the last inspection. The liner in
lagoon 3 was patched.
Four wells are currently being sampled three times a year. All wells on the site have
permanently affixed tags, concrete pads and locked protective covers.
A soil sample was collected in April. No lime was recommended.
NDMR and NDAR records have been submitted complete and on time. 0&M documents, lab
results and other records were reviewed and were in good order.
The system is inside a fence and signs were posted to limit access per the permit. The lagoons
banks were covered with appropriate vegetation and appeared well maintained. The pump
runs on a timer. Flow is measured by a meter which is calibrated annually.
On the day of the inspection, the facility appeared to be well run and in compliance with
permit conditions
Please see the attached inspection Report.
if you have any questions regarding this letter, please contact me at (919) 791-4240 or via
e-mail at Egy.miloshr(@ncdenr.gov.
Sincerely,
L
Ray Milosh
Environmental Specialist
Division of Water Resources, Water
Quality Regional Operations Section,
Raleigh Regional Office
Attachment: Compliance Inspection Report
CC' RRO-WQROS Files
DWR Central Files
Compliance Inspection Report
Permit: W00002428 Effective: 03/22/18 Expiration: 10/31/20 Owner: Mountaire Farms Inc
SOC: Effective: Expiration: Facility: Mount Vernon Hatchery WWfF
County. Chatham 175 Foust Rd
Region: Raleigh
Stier City NC 27344
Contact Person: Douglas Goodwin Title: Phone: 919-663-2050
Directions to Facility:
System Classifications: SI,
Primary ORC: Douglas Wayne Goodwin Certification: 18557 Phone: 919-548-5024
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 09/2412019 Entry Time: 03 30PM Exit Time: C�5 G4PM
Primary Inspector: Raymond M Milosh Phone: 919-791-4200
Secondary Inspector(s):
Reason for Inspection: Rout.ne
Permit Inspection Type: Wastewater Irrigation
Facility Status: Compliant Not Compliant
Question Areas:
Inspection Type: Compliance Evaluation
Treatment Flow Measurement -Effluent 0 Treatment Flow Measurement -Influent Miscellaneous Questions
Treatment Flow Measurement -Water N Reccrd Keeping Treatment Lagoons
Use Records
End Use -Irrigation Treatment Flcw Measurement
(See attachment summary)
Page 1 of 5
Permit: W00002428 Owner -Facility'. Mounia-re Farms Inc
Inspection pate: 0912412019 Inspection Type : compliance Evaluation Reason for Visit: Routine
Inspection Summary*
Staff of the NC Division of Water Resources (DWR), Water Quality Regional Operations Section (WQROS) inspected
Mountaire Farms' Mount Vernon Hatchery Wastewater Treatment and Surface Irrigation System Permit No. W0000242B on
September 24, 2019. 1 would like to thank you for your assistance during the inspection.
Doug Goodwin is currently designated as ORC and Robert Jackson is designated as Back-up ORC.
The permit does not require metering water flowing to the lagoon. Wastewater flows to the lagoon from four separate pipes.
Three are "process water" and one is domestic. The domestic wastewater flows through septic tank and a Cl tablet
chlorinator. The tank is pumped four times each year.
The flow rate reported on NDMR's is the total of the water pumped to the sprayfields. About 30,000 gallons of wastewater
per week is being hauled to this facility from the other hatchery.
Application rates have risen to 11 — 18 inches per year which is within the 25.71' permitted
The residual chlorine meter always reads 0.03. Staff intend to determine if it is working by running more highly chlorinated
water through it and looking for a response.
Levels in aeration lagoons are controlled by set overflow pipes which send flows to storage lagoon. The level gauges
appeared properly installed and easily legible.
Bob Branch profiled the lagoons for residuals. Lagoon 1 and 2 will be dredged in 2019 or 2020. One field was fertilized in
2019. The third cutting of hay is underway.
One aerator broke on Saturday. It will be repaired in 2 weeks. The aerator panel was replaced in 2018. One sprayfield
pump was replaced since the last inspection. The liner in lagoon 3 was patched.
Four wells are currently being sampled three times a year. All wells on the site have permanently affixed tags, concrete
pads and locked protective covers.
A soil sample was collected in April. No lime was recommended.
NDMR and NDAR records have been submitted complete and on time. O&M documents, lab results and other records were
reviewed and were in good order.
The system is inside a fence and signs were posted to limit access per the permit. The lagoons banks were covered with
appropriate vegetation and appeared well maintained. The pump runs on a timer. Flow is measured by a meter which is
calibrated annually.
On the day of the inspection, the facility appeared to be well run and in compliance with permit conditions.
Page 2 of 5
Permit: W00002428 Owner . Facility: Mountaire Farms Inc
Inspection Dale: 0912412019 Inspection Type : Compliance Evaluaban
Reason for Visit: Routine
Type
Yes No NA NE
Infiltration System
❑
Single Family Spray, LR
Activated Sludge Spray, LR
rl
Activated Sludge Spray, MR
Reuse (Quality)
El
Activated Sludge Drip, LR
Recycle/Reuse
Single Family Drip
Lagoon Spray, LR
■
Treatment Flow Measurement -Influent
Yes No NA NE
Is flowmeter calibrated annually? El . 0
Is flowmeter operating properly? ■ ❑
Does flowmeter monitor continuously? .
Does flowmeter record flow? ❑
Does flowmeter appear to monitor accurately? ■
El El El
Comment:
Treatment Flow Measurement -Water Use Records
Yes No NA NE
Is water use metered?
Are the daily average values properly calculated? El El 11 El
Comment:
Treatment Flow Measurement -Effluent
Yes No NA NE
Is flowmeter calibrated annually? .
11 El El
Is flowmeter operating properly? ■
El El rl
Does flowmeter monitor continuously? ■
El 0 El
Does flowmeter record flow? ■
Does flowmeter appear to monitor accurately? ■
El [10
Comment:
Record Keenan
Yes No NA NE
Is a copy of current permit available? .
0 El El
Are monitoring reports present NDMR? ■
NDAR? ■ 1:111
❑
Are flow rates less than of permitted flow? ■
1:1 El El
Are flow rates less than of permitted flow? .
Page 3 of 5
Permit: W00002428 Owner - Facility:Ivlountaire Farms Inc
Inspection Date: 09/2412019 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
N ❑ 11
Are application rates adhered to?
Is GW monitoring being conducted, if required (GW-59s submitted)?
S ❑ 0 El
Are all samples analyzed for all required parameters?
0 ❑ ❑
Are there any 2L GW quality violations?
S ❑
Is GW-59A certification form completed for facility?
S
Is effluent sampled for same parameters as GW?
El 0
Do effluent concentrations exceed GW standards?
El ❑ 0 11
S
Are annual soil reports available?
S 11 ❑ ❑
# Are PAN records required?
# Did last soil report indicate a need for lime?
C1 0 0
0
If so, has it been applied?
0
Are operational logs present?
0
Are lab sheets available for review?
Do lab sheets support data reported on NDMR?
❑ 0 El 0
Do lab sheets support data reported on GW-59s?
E El ❑ 11
Are Operational and Maintenance records present?
E
Were Operational and Maintenance records complete?
0
Has permittee been free of public complaints in last 12 months?
N
Is a copy of the 50C readily available?
No treatment units bypassed since last inspection?
❑ 1:1 El
Comment:
End Use -Irrigation
Yes No NA NE
Are buffers adequate?
Is the cover crop type specified in permit?
Is the crop cover acceptable?
0 ❑ 0 El
Is the site condition adequate?
E
Is the site free of runoff I ponding?
E El El El
Is the acreage specified in the permit being utilized?
N El ❑
Is the application equipment present?
E El ❑
Is the application equipment operational?
N
Is the disposal field free of limiting slopes?
0
Is access restricted andlor signs posted during active site use?
N
Are any supply wells within the CS?
0 El S
Are any supply wells within 250' of the CI3?
El El 0 El
How close is the closest water supply well?
S
Is municipal water available in the area?
0 D N 11
Page 4 of 5
Permit: VV00002428
Inspection Date: 0912412019
Owner - Facility:Mountaire Farms Inc
Inspection Type : Compliance Evaluation
Reason for Visit: Routine
# Info only: Does the permit calf for monitoring wells? ■ ❑ ❑ ❑
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Are monitoring wells damaged?
Comment:
Page 5 of 5