HomeMy WebLinkAboutWQCSD0508_Compliance Evaluation Inspection_20190930ROY COOPER MICHAEL 5, REGAN S.trre ary LINDA CULPEPPER Ctu: e;t7r Mr. Levell Langley, Mayor Town of Red Oak P.O. Box A Red Oak, N.C. 27868 `JT, . `n Envirurmsn:ai Q,alir. September 30, 2019 Subject: Compliance Evaluation Inspection Red Oak Collection System Collection System PermitNo: %VQCSD0508 Nash County Dear ,Mayor Langley: it f4r! 19' On September 4, 2019, Cheng Zhang of the Raleigh Regional Office (RRO) Division of Water Resources conducted a Compliance Evaluation Inspection of the subject facility. The assistance and cooperation of Mr. Scott Farmer, the operator of the system, and 11r. Jonathan Boone, Nash County Utilities Director, were very helpful and appreciated. A checklist of items is enclosed with this letter. During the inspection the following items were noted: 1.) Town of Red Oaks holds a deemed sewer collection system permit in Nash County (Nash County Public Utilities Department is operating and maintaining the system). There has been no reportable sanitary sewage overflow (SSO) incidents from the collection system since the last inspection. 2.) The collection system includes gravity sewer lines. force mains, and two duplex pump stations. 3.) The facility maintains a map of the system to include all required elements. 4.) The facility has developed and implemented an operation and maintenance plan which Iists the frequency of system inspections, prey-entive maintenance schedule (right -or -way maintenance), and overflow response plan. 5.) Grease educational flyers are sent to all users semi-annually. 6.) During the inspection, the two pump stations were obsen-cd and found to be in good condition. 7.) The right-of-way behind 5378 Red Oak Road was maintained and accessible. Sewer line clearing has not been conducted since the system was built in 2007, preventive line cleaning and maintenance may be considered and planned in the future. If you have any questions regarding the attached report or any of the findings, please contact Cheng Zhang at: (919) 791-4200 (or email: cheng.zhanY-u ncdenri-gov). Sincerely, 447 Rick Bolich, L.G. Assistant Supervisor Division of Water Resources Ralei�-li Regional Office Attachments: Compliance Inspection Report Cc: Central Files w::attachment Raleigh Regional Office w :attachment Scott Farmer, Nash County, w..'attachment (electronic copy only) Compliance Inspection Report Permit: WOCSDO508 Effective, D1;26r10 Expiration SOC: Effective: Expiration, County: Nash Region: Raleigh Contact Person: Derek Hawkes Titrr,. Directions to Facility: System Classifications: Primary ORC: Certification: Secondary ORC(s): On -Site Representative(s): On-s to representative S--ctt Fanr.er Owner: Town of Red Oak Facility: Town of Red Oak Sanitary Sewer System Phone: 252462-2613 Phom: Related Permits: NCO030317 City of Rocky Mount - Tar River Regional VjYjiP WQCS0001 S City of Rocky Mount - Rocky Mount Collection System Inspection Date- 09f0+2019 Entry Time: 09 30AM Exit Time: 11 00AM Primary Inspector: Cheng Zhang Phone: 919-7914200 Secondary Inspector{s): Reason for Inspection; Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: Compliant Not Compliant Question Areas: Miscellaneous questions N General Grease Control Spills/Response Plan N Inspec4ans Lines Manholes N Pump Stations (See attachment summary) Page i of 6 Permit: WOCSDO508 Owner • Facility' Town cf Red Oak Inspection Datet 09104-Wig Inspection Type : Ccllecticn System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE # Is this system a satellite syslem7 e ❑ ❑ # If Yes, what is system name or perrrW number? WQCS000t 1 Is there a overall sewer system map? 0 ❑ ❑ El Does the map include Pipe sizes ■ ❑ ❑ ❑ Pipe materials (PVC, DIP, etc) ■ ❑ ❑ ❑ Pipe location . ❑ ❑ ❑ # Flow direction . # Approximate pipe age ■ El El El # Pump station ID, location and capacity 0 El El El # Force main air release valve location & type D El 0 El # Location of satellte connections ■ Are system maintenance records maintained? ■ Comment: Grease Control Yes Na NA NE Is greaselsewer education program documented with req'd customer distribution? El 00 # Are other types of education tools used like webs tes. booths special meetings, etc? ■ If Yes what are they? (This can reduce mailing to annual.) For public systems is there a Grease Control Program via an ordinance/agreement? 0 El❑ ❑ If Yes. does it require grease control devices at applicable locations? ❑ ❑ M Is the Grease Control Program enforced via periodic inspections/records review? ❑ ❑ Is action taken against violators? ■ Comment: No rease trap slinterce tors in the system, Spills and Resnonse Action Plan " Yes No NA NE # Is system free of known points of bypass? ■ El 1:10 If No describe type of bypass and location # Have there been any Sevier spills in the past 3 years? M ❑ El If Yes were they reported to the Division if meeting the reportable criteria? El El 0 D If applicable, is there documentation of press releases and public notices issued? Are all spills or sewer related issueslcomplaints documented? El D ■ El # Are there repeated overflows/problems (2 or more :n 12 months) at same location? ❑ El ■ ❑ # If Yes, is there a corrective action plan? ❑ M ❑ Is a Spill Response Action Plan available? ■ Is a Spill Response Action Plan available for all personnel? Page 3 of 6 Permit: WOCSDO508 owner -Facility: Town of RedCak Inspection Date: 09/0412019 Inspection Typo. Ccltection System lnspert i'lon Samrlir; Reason for Visit Rc..Pe Does the plan include: # 24-hour contact numbers ■ ❑ ❑ ❑ # Response time . # Equipment list and spare pans inventory ■ Cl ❑ 13 # Access to cleaning equipment ■ El ❑ ❑ # Access to construction crews, contractors, and/or engineers ■ # Source of emergency funds El D # Site sanitation and cleanup materials ■ # Posl-overllowlspill assessment ■ ❑ ❑ Comment: The Plan was updated on September 4. 2019 after the site visit. Inspections Are adequate maintenance records maintained? Yes No NA NE ❑ El Are pump stations being inspected at the required frequency? . Is at least one complete functionality test conducted weekly per pump station? ■ Is there a system or plan in place to observe the entire system annually? ■ ❑ El 11 Is the annual inspection documented? 1:1 Cl # Does the system have any high -priority lines/locations? ■ ❑ Are inspections of HPL documented at least every 6 months? El ❑ ■ ❑ Are new lines being added to the HPL list when found or created" ❑ ■ ❑ Comment No high -priority lines in the system Lines/Right-of-Ways/Aerial Lines Yes No NA NE Please list the Lines/Right of WaysiAerial Lines Inspected Two outfall Imes jo n together behind 5378 Red Oak Road were visited during the inspection. Oulfall lines were maintained and accessible. Are right-of-ways and easements maintained for the full w'dlh for access? ■ If No. g ve dela'Is on temporary access: Is ma-nteriance documented? ■ ❑ ❑ Were all areaslhnes inspected free of issues? . ❑ ❑ Comment: Manholes Yes No NA NE Please list the Manholes Inspected: Manhole at where the two outfall lines join. Are manholes accessible? ■ # Are manhole coverslvents above grade? . Are manholes free of visible signs of overflow? 11 . ❑ El Are manholes free of sinkholes and depressions? ■ ❑ ❑ Are manhole covers present? ■ 11 ❑ ❑ Page 4 of 6 Permit: WOCS00508 Owner - Facility: Town of Red Oak Inspection bate: 09104/2019 Inspection Type : CCliectian System Inspect Non Sampling Reason for Visit: Routine # Are manholes property seated? ■El E]❑ # Are manholes in good condition? ■ ❑ El 0 # Are ,nverts in good condition? ■ Is flow unrestricted in manholes? ■ 0 Are manholes free of excessive amounts of grease? MC1 El ❑ Are manholes free of excessive roots? ■ O 0 El Are manholes free of excessive sand? ■ El 1:1 El Are manhole vents screened? ■ ❑ 1:1 El Are vents free of submergence? ■ Are manholes free of bypass structures or pipes? ■ Comment; Pump Stations - Yea No NA NE Please list the Pump Stations Inspected Red Oak Park Pump Station Red oak Main Pump Station # Number of duplex or larger pump stations in system 2 # Number of vacuum stations in system o # Number of simplex pump stations in system 0 # Number of simplex pump stations in system serving more than one building 0 Wow many pumpivacuum stations have. # A two-way "auto polling" communication system (SCADA) installed? t # A simple one-way telemetrylcommunication system (auto -dialer) installed? t For pump stations inspected; Are they secure with restricted access? ■ Were they free of by-pass structuresipipes? ■ El 1:1 El Were wet wells free of excessive grease/debris? ■110 ❑ # Do they all have telemetry installed? ■ Is the telemetry system functional? ■El❑ ❑ Is a 24-hour notificat°on sign posted ? ■ ❑ ❑ ❑ Does the sign include Owner Name? ❑ ❑ ❑ Pump station identifer? ■ El ❑ El # Address? ■ ❑ El D Instructions for notification? M 24-hour emergency contact numbers? ■ Are audio and visual alarms present? .El U Are audio and visual alarms operable? ■ ❑ El ❑ Page 5 of 6 Permit: WQCSD0508 Owner • Facility: Town of Red yak Inspection Date: 09/04/2019 Inspection Type : CcIlectico System Inspe2t Non Sampling Reason for Visit f -t-t # Is there a backup generator or bypass pump connected? ■ If tested during inspection, did it function properly? 0 El ■ El Is the back-up system tested at least bi-annually under normal operating conditions? . # (Does it have a dedicated connection for a portable generator? ■ # Is the owner relying on portable units in the event of a power outage) ❑ ■ ❑ # If Yes, is there a distribution plan? ❑ . If Yes, what resources (UnitslStaffNehiciesletc) are included in Plan') # Does Permittee have the approved percentage of replacement simplex pumps'? ❑ El ■ ❑ Is recordkeeping of pump station inspection and maintenance program adequate') Do pump station logs include at a minimum Inside and outside cleaning and debris removal? ■ ❑ ❑ ❑ Inspecting and exercising all valves? . ❑ Inspecting and lubricating pumps and other equipment? . ❑ ❑ Inspecting alarms, telemetry and auxiliary equipment? ■ ❑ ❑ ❑ Comment: Red Oak Main Pump Station is equipped with on -site clenerator, bypass valve. and SCADA_ Rea Oak Park Pump Station serves one building Office and bathrooms and has no backu awer, in case of Power outra e. the bathrooms will be closed. It is equipped with simple telemetry. Page 6 of 6