HomeMy WebLinkAbout20191303 Ver 1_Permeable Pavement Calcs_20190930Bradford Circle Water Quality Depth Calculations ❑wq = P(1+R) n where: D. q = Depth of aggregate needed to treat the water quality storm (inches) P - Rainfall depth for the water quality storm (inches) R = A,,fAp. ratio of the additional SUA to permeable pavement area N = Percent voids, unitless decimal (from ASTM C29) Given Depth of Aggregate P= 1 in When: Aa 1778 sf R = Aa/Ap = 0.38 Ap 4665 sf N 0.38 Dwq = 3.63 inches Page 9 Draw Down Calculations Bradford Circle Permeable Pavement Water Quality Volume (Ft') 501.6 Total WQv Required Top Elevation of Temp Pool (Ft) 337.15 Overflow Elevation Orifice Invert Elevation (Ft) 334.97 Reservoir 3 Elev. Used Maximum Head (Ft) 2.16 At Centroid of Orifice Driving Head Ho (Ft) 1.08 1/2 Maximum Head Orifice Diameter (in) 0.50 Orifice Diameter (Ft) 0.04 Orifice Area (Ft2) 0.001 Orifice Coefficient 0.59 Orifice Discharge Q (Ft3/s) 0.01 Days to Complete Drawdown 0.87 Between 2 and 5 Days Q = CDA 2gHo Stage Storage Calculations Elev. (Ft) Area (sf) Volume (cf) 336.82 4000 1320 337.15 4000 Note - Reservoir Elevations Vary WQv 1320 Voids 0.38 Total WQv Provided (cf) 501.6 Where: Q = Discharge (cfs) CD = Coefficient of discharge (dimensionless) - see Table 3-8 A = Cross -sectional area of flow at the orifice entrance (sq ft) g = Acceleration of gravity (32.2 ft/ sec2) Ho = Driving head (ft), measured from the centroid of the orifice area to the water surface - Note: Usually use Ho/3 to compute drawdown through an orifice to reflect the fact that head is decreasing as the drawdown occurs. Figure 3-3 Schematic section through an orifice =zR2 Table 3-8 Values of Coefficient of Discharge, CD (Malcom, 1989) Entrance Condition CD Typical default value 0.60 Square -edged entrance 0.59 Concrete pipe, grooved end 0.65 Corrugated metal pipe, mitred to slope 0.52 Corrugated metal pipe, projecting from fill 1.00 Page 10