Loading...
HomeMy WebLinkAboutNC0080071_Renewal (Application)_20190930 4e, II....X ..3 N f,... .6,, 1 ,,. :. , ROY COOPER ' _ - ' Governor �,a ^,y y 7 �,; MICHAEL S.REGAN �w.,or.• Secretary ''''sr quksor d'�' LINDA CULPEPPER NORTH CAROLINA Director Environmental Quality September 30, 2019 Town of Vanceboro Attn: Chad E. Braxton, Mayor PO Box 306 Vanceboro, NC 28586-0306 Subject: Permit Renewal Application No. NC0080071 Vanceboro WTP Craven County Dear Applicant: The Water Quality Permitting Section acknowledges the September 30, 2019 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit.The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely, kaCMC k;\ Wren The ford Administrative Assistant Water Quality Permitting Section ec: WQPS Laserfiche File w/application =��b North Carfl ne Department of Environmental Qua1 ty� I Divis'vavniWater ftesoarcea D E a%'rl Washington Ragiona8 QfF l �43 Washington S nare Mel] l 1'�sshington,North CaraGna 27889 b�.e,«`s�mi., o.au V 252-94S-6481 01, v�� Alderman Stephen Belrose Mayor Chad Braxton ref Alderman Keith Cannon Alderman Todd McMillen Alderman Dennis Smith Town Clerk Beverly Drake Alderman Billy Whitford September 26, 2019 NC DEQ, Division of Water Resources RECEIVED Water Quality Permitting Section-NPDES SEP 3 0 2019 1617 Mail Service Center Raleigh, N. C. 27699-1617 NGDEQIDWRINPDES Attn: Mr. Wren Thedford The Town of Vanceboro is submitting our Permit Application for the Water Treatment Plant, Permit#NC0080071. The discharge evaluation report will be submitted separately. If you have any questions please give us a call at 252-244-0919. Sincerely, gd- Chad E. Braxton Mayor NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number NC0080071 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise,please print or type. 1. Contact Information: Owner Name The Honorable Chad E. Braxton, Mayor Facility Name Town of Vanceboro Mailing Address P.O. Box 306 City Vanceboro State / Zip Code North Carolina 28586 Telephone Number (252)244-0919 Fax Number (252)244-1387 e-mail Address 2. Location of facility producing discharge: Check here if same as above ❑ Street Address or State Road 923 Farm Life Avenue City Vanceboro State / Zip Code North Carolina 28586 County Craven 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Vernon M. Edwards,Public Works Director Mailing Address P.O. Box 306 City Vanceboro State / Zip Code 28586 Telephone Number (252)244-0919 Fax Number (252)244-1387 4. Ownership Status: Federal ❑ State ❑ Private ❑ Public X Page 1 of 4 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants 5. Type of treatment plant: ❑ Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by filtration and disinfection) X Ion Exchange (Sodium Cycle Cationic ion exchange) ❑ Green Sand Filter (No sodium recharge) ❑ Membrane Technology (RO, nanofiltration) Check here if the treatment process also uses a water softener X 6. Description of source water(s) (i.e. groundwater, surface water) Two groundwater well sources. 7. Describe the treatment process(es) for the raw water: Aeration, Filtration, Softening, and then gas chlorination. 8. Describe the wastewater and the treatment process(es) for wastewater generated by the facility: Wastewater generated by the water treatment plant comes from backwashing of the filter and the regeneration cycle of the ion exchange softener. 9. Number of separate discharge points: 1 Outfall Identification number(s) 001 10. Frequency of discharge: Continuous ❑ Intermittent X If intermittent: Days per week discharge occurs: 2-3 Duration: 88 minutes 11. Plant design potable flowrate 0.432 MGD Backwash or reject flow 0.016 MGD 12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Unnamed tributary to Mauls Swamp. 13. Please list all water treatment additives, including cleaning chemicals or disinfection treatments, that have the potential to be discharged. Page 2 of 4 Version 5/2012 NPDES PERMIT APPLICATION_- SHORT FORM C -,WTP For discharges associated with water treatment plants Alum / aluminum sulfate Yes No X Iron sulfate / ferrous sulfate Yes No X Fluoride Yes No X Ammonia nitrogen / Chloramines Yes No X Zinc-orthophosphate or sweetwater CP1236 Yes No X List any other additives below: Gas chlorination utilized for disinfection. 14. Is this facility located on Indian country? (check one) Yes ❑ No X 15. Additional Information: ➢ Provide a schematic of flow through the facility, include flow volumes at all points in the water treatment process. The plan should show the point[s] of addition for chemicals and all discharges routed to an outfall [including stormwater]. ➢ Solids Handling Plan 16. NEW Applicants Information needed in addition to items 1-15: ➢ New applicants are highly encouraged to contact a permit coordinator with the NCDENR Customer Service Center. Was the Customer Service Center contacted? ❑ Yes ❑ No ➢ Analyses of source water collected ➢ Engineering Alternative Analysis ➢ Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a water quality model. 17. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. The Honorable Chad E. Braxton Mayor P ' ed name f P son Sjigning Title Signature of Applicant Date North Carolina General Statute 143-215.6(b)(2)provides that Any person who knowingly makes any false statement representation,or certification in any application, record,report,plan,or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,or who falsifies,tampers with,or knowingly renders inaccurate any recording or monitonng device or method required to be operated or maintained under Article 21 or regulations of The Environmental Management Commission implementing that Article,shall be guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by Page 3 of 4 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants imprisonment not to exceed six months,or by both (18 U.S.C.Section 1001 provides a punishment by a fine of not more than$25,000 or imprisonment not more than 5 years,or both,for a similar offense.) o L Page 4 of 4 Version 5/2012 • - (---..—__ a Alt(re.."..-.A 'I .Can;; , 4 1. " *, �' - -,. r' t !j � 1 rt i : : .I i".-.. ( TAH D.- \--'4•,--... •/tle.40,...\:),„C ) (--re? fr-.7,-,..----- 1-IN • .1.-," ,ezi i .. ipi • • ...41• AI (\-.1f, 0.---' ;,/,„).) ,/,/- iaa - • ..At, sl `e ifs • ! Ii1 J./`...,.-.1) :-"-:.--:.::.-..:7,--:' ii.1:.EtI , . 4. y .„,k;. 1' tom„ 1 - ;4Ji ;r_,t-, \. f ; .y -4i 3 f ,'y-',, ;o, ,�' 1' Vanceboro WTP `,.,,w 4', _._ ._.. ._ .... .,..,...,..,„.„..„...... 1..,1...'2.....-r,.1 :: ...f1ii:, I, .--- -\„,.. ....,..-- .:z•-ik.. t '.4414' 41**4i`-r. ii,. -)4/5C1‘'`kfC>\‘4:::Z:47::(71:---;+:: -.."'-'''7':''''' '- ✓f'' 1 r ti'4l,l14„IL.-4—.7...I1r..)c.J • Discharge 7 cena rs1i (i NC0080071 ` ' iy F•_ `' � fl 11/141;70; '—1— NN c". '7' ...k.'s .r ..i .0: "fl-A--',' ,‘;.,-4;•- ' :71.1/4,c-r\,...ds:1".:C"••-•,. ..je.--.C.---,s1 I i'eft 7. , 15.1.1, _.„. ./.4.. ;1 ;:-...,,• ) ,"..",, , ....41111102BIF"r1"-:— i?`" ---...,_____ .„;),./1 -Li 1 " 1..._ k. "�..�,— 1 ,- ate{6 i(k,./4 ,,,,,, 1/ ,t .f •-AE6 ":h '�. ��• i' ''� ' • . '' 1 - c f 1..'- '�•' --`) jl v1� 4 f •• re\W US 17 k (Ib 1 9 -.4:11,k;:• • J �j 1 ,1. ,'.,i' ! r < % M • ! f { �✓till.v {",P�y�' (1 1„�lr�l' kci ' • }` ` 'te . ma , .(� ry _7 - . , l Dr\ 1.. .-` y (i \ C ^ c rr'-.._„ ... ,• '/ ✓f<r ' '' ;? { 11! ;/ It s ,r1. .r . kl \s. 4244-""-'---1.,--.--TA.:..,-.5iNJ '.- k ,4---k74---5---fv__:,. -) GI 1,1 - ; z___ ;.• l i.X.-O. ,_t.. 1 '''•-• (1%1; . k L 1 4 k,'II;If'—. ..--, -....„•-. ..,--; \ , •,, C h\ ,.:11:1 N.. __,.4• f• SCALE:1 ill=24000ft USGS Quad:F30SW Vancebbro NC •9t .�- •�- F '��• Outfall Facility r� `y �` 7 r ' Latitude: 35° 18' 13.6"N 35° 18' 15.1"N , , ut, ''�L' = ;'l`l,,:Nw'F`r: •` ,1 Longitude: 77° 8' S1.1"W 77° 8' 50.3 `;;.a* ,--' -QV OP 14-V:'a}`.1't - ha. Stream Class: C, Sw,NSW Facility Location ' i.`15t North q,:,r Subbasin: 03-04-09 HUC: 03020202 Vanceboro WTP NC0080071 Receiving Stream: UT to Mauls Swamp Craven County GAS CHLORINATION— WELL#1 AERATOR ►FILTER ION EXCHANGE SOFTENER ► DISTRIBUTION SYSTEM Well#2 10,880 GALLONS - 5,400 GALLONS 0.016 MGD ►V ► UNNAMED TRIBUTARY TO MAULS SWAMP OUTFALL 001 Town of Vanceboro WTP Discharge NC0080071