HomeMy WebLinkAboutWQ0009772_Compliance Evaluation Inspection_20190930w+,_rr a ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Dir(Ytor NORTH CAROLINA Environmental QualO September 30, 2019 Dana Hill Carolina Water Service Inc of North Carolina PO Box 240908 Charlotte, NC 28224 SUBJECT: Compliance Inspection Report Monteray Shores WWTP Non -discharge Permit No. WQ0009772 Currituck County Dear Mr. Hill: The North Carolina Division of Water Resources conducted an inspection of the Monteray Shores WWTP on 8/28/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0009772. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact Sarah Toppen with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at Sarah.Toppen@ncdenr.gov. Sincerely, 3ayah Jow Sarah Toppen, Environmental Specialist Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Washington Regional Office - Enforcement File NON -DISCHARGE Compliance/Enforcement Unit - Enforcement File ��Nortt Caro no Departmgent& Ervr�orrrerta Qi s ty I D .sorof Water Resources V1ast ngmr. Regors Dffce 1943 Wash rotor S,aare Na' I Wast rpor., North Caro :re 27889 ,,,,! 252-946-6"1 Permit: WQ0009772 SOC: County: Currituck Region: Washington Contact Person: Dana Hill Compliance Inspection Report Effective: 05/12/16 Expiration: 04/30/21 Owner : Carolina Water Service Inc of North Carolina Effective: Expiration: Facility: Monteray Shores WWTP 819 Malia Dr Corolla NC 27927 Title: Director of Operations Phone: 704-319-0503 Directions to Facility: From intersection of Hwy 158 and Hwy 12 in Southern Shores take Hwy 12 north to Malia Drive. Turn left (west) onto Malia and proceed to WWTP. The turn off on Hwy 12 to the WWTP is just south of a convenience store. System Classifications: WW4•, Primary ORC: Matthew Lynn Palmiter Certification: 1000301 Phone: 910-376-4185 Secondary ORC(s): On -Site Representative(s): Related Permits: WO0006254 Carolina Water Service Inc of North Carolina - Corolla Light WWTP #1 Inspection Date: 08/28/2019 Entry Time: 01:OOPM Exit Time: 02:15PM Primary Inspector: Sarah A Toppen Phone: 252-946-6481 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: High Rate Infiltration Facility Status: Compliant Not Compliant Question Areas: Miscellaneous Questions Treatment Treatment Barscreen Record Keeping Treatment Activated Sludge Treatment Clarifiers Treatment Disinfection M End Use -Infiltration Treatment Return pumps Standby Power 0 Wells (See attachment summary) Page 1 of 6 Permit: W00009772 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/28/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On August 28, 2019, Sarah Toppen and Randy Sipe with NCDEQ DWR conducted a compliance inspection with Matt Palmiter and John Schwartz present for the facility. The facility appears to be in compliance based on the day of inspection. Look at the questions following this summary for more details. Page 2 of 6 WI WI ❑ ❑ Q Q E] ❑ z z Z ❑ ❑ Z } ❑ ❑ ❑ ❑ ❑ El El El El ; ■ ■ .0 N D_ c t 7 U N L C [Y J J Q E a, m n cn o cn O J o. N N N T w >, N �" 7 7 7 .7 � U)a E E U) in U) Ci co cn is co -0 -o -o c Il aD U- (D u) 2 7 tz O 01 �>'j a z >CD > m o (n In Q Q Q C N E E O U ❑ ❑ ❑ ❑ Q Z ❑ ❑ ❑ ❑ Z ■ ■ ❑ ❑ ❑ ❑ ❑ ❑ Q z ZOODO N U C N Q N U , Cl. c c O C N rn 2a -0 c O_ C > es N U N U N O mX N N M N O N c ++ _ C E a o +' :z E y .- O N w O t N 2 Q N U WI ❑ ❑ ❑ ❑ ■ ❑ Q ❑ ❑ ❑ ❑ ❑ ❑ Z z° ❑ ❑ ❑ ❑ ❑ ❑ Cl. Cl.Cl. N O N O N X U O U U f6 N W a L u) d w0 O m U O E o Q m c°i O aci v m y m - E f° c <6 U C a c cn N N N 7 N r E mm w a� o f� > Q O O O N r- 2 m .6 > aoi m c c aD E m m m o co E co w > E 7T y Permit: WQ0009772 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/28/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Treatment Clarifiers Yes No NA NE Are the weirs level? ❑ ❑ ❑ Are the weirs free of solids and algae? ❑ ❑ N ❑ Is the scum removal system operational? ❑ ❑ 0 ❑ Is the scum removal system accessible? ❑ ❑ M ❑ Is the sludge blanket at an acceptable level? ❑ ❑ N ❑ Is the effluent from the clarifier free of excessive solids? E ❑ ❑ ❑ Comment: This facility uses Membrame Bioreactors (MBRs) this replaces the secondary clarification. Treatment Return pumps Yes No NA NE Are they in place? N ❑ ❑ ❑ Are they operational? 0 ❑ ❑ ❑ Comment: Treatment Disinfection Yes No NA NE Is the system working? 0 ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? E ❑ ❑ ❑ Is there adequate detention time (-30 minutes)? 0 ❑ ❑ ❑ Is the system properly maintained? E ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ 0 ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ 0 ❑ Is the chlorinator accessible? ❑ ❑ E ❑ If tablets, are tablets present? ❑ ❑ 0 ❑ Are the tablets the proper size and type? ❑ ❑ N ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ 0 ❑ If UV, are extra UV bulbs available? 0 ❑ ❑ ❑ If UV, is the UV intensity adequate? 0 ❑ ❑ ❑ # Is it a dual feed system? 0 ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ 0 ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ 0 ❑ If yes, then what is the EPA twelve digit ID Number? (1000-_ If yes, then when was the RMP last updated? Comment: UV disinfection appeared to be working and there are extra bulbs present. Record Keeping Yes No NA NE Is a copy of current permit available? E ❑ ❑ ❑ Are monitoring reports present: NDMR? E ❑ ❑ ❑ NDAR? 0 ❑ ❑ ❑ Page 4 of 6 Z O C O U) m d K 3 3 0 C a) E E C a) n Q O O c c m m w N U! a� a) () a) c0 l�6 O O G= C= N N Q Q Q u! CD CO U) n O m w ` Q O _N m a m o E m > U C- oE a) a m O Ca7 N Q C U) > q o Co a m > (u E 'ac U m E m Q CO Um) Cf) C a) d cc L j 7 2 ( N Q Q U) U) Cl. c`- Cl.Lo a) E Z A C C 12 O O Cl. Cl. N Cl. 3 = 'C a) C a O O O m a) > Q CL m c a) 'n C 2 N 2 m O U cc N `O m m m m r m aa)) cL o O a m ur O O Q (n O rn C n Q d 'O - N O > > 7 O U N — L m mC U) U) N 2?Z ' o S a) d m O Q C m N O O m m N Q 0 N N O O Q * # Q Q U 0 R wl ❑ ■ ■ ❑ ❑ ■ ■ a 0000000 zz 0000000 m cl- m U r. CD m L � Cl. m m o U w O Cl L LO C N C C N L L L m � w � 3 3 >. n n CL 3 n Q U) c n U) co �U T T m m O 2 E Q Q H W. T N CT m a Permit: W00009772 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/28/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is a usable green area maintained? M ❑ ❑ ❑ Is the disposal site acceptable? M ❑ ❑ ❑ Is the distribution equipment acceptable? 0 ❑ ❑ ❑ Is the disposal site free of ponding? ❑ 0 ❑ ❑ Is the disposal site free of breakout? 0 ❑ ❑ ❑ Are the disposal sites free of solids, algae, etc.? M ❑ ❑ ❑ Do the records show that the fields are properly maintained? ❑ 0 ❑ ❑ Are the disposal sites free of vegetation? ❑ M ❑ ❑ Do any surface water features appear to be adversely impacted by GW discharge? ❑ 0 ❑ ❑ No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? 0 ❑ ❑ ❑ Comment: A wet infitration site was observed. MW-12 was observed and it appeared to be locked. There was water standing around the base of the monitoring well. Page 6 of 6