Loading...
HomeMy WebLinkAboutNCG550105_Compliance Evaluation Inspection_20190930DocuSign Envelope ID: D5274933-5A04-4CA2-8024-7DE4689083DA ROY COOPER G&v-�rr1ar K41 HAEL S. REGAN Secretary LINDA CULPEPPER arwfar Roger D Garland 14196 NC Hwy 226 N Bakersville, NC 28705 NORTH CAROUNA Environmental Quality September 27, 2019 SUBJECT: Compliance Inspection Report 14196 NC Highway 226 North NPDES WW Permit No. NCG550105 Mitchell County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the 14196 NC Highway 226 North on 9/18/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NCG550105. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me at 828-296-4500 or via email at linda.wiggs@ncdenr.gov. Sincerely, DocuSigned by: -4 .,,d,� ZO*4- 6C38CDE2B5CF449... Linda Wiggs Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS -Inspection Report Ec: ARO Server, LF G:\WR\WQ\Mitchell\Wastewater\General\NCG55 SFR\Garland NCG550105\9-18-2019 Inspection\20190930_NCG550105_CEI.rtf Nortl Caro:!ra Departnentof Er.v:ronmeuta;Quairty I Diuisiouof Water Resources Asbev;;:e Regnna:4ff:ce 1 2090 U.S. 70 F?glm-sy I Swannsmos, North Caro:ars 2377S DocuSign Envelope ID: D5274933-5A04-4CA2-8024-7DE4689083DA United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCG550105 111 12 I 19/09/18 I17 18 I S J 19 L G] 201 I 211111 1 1 I I I I II I I I I I I I I I I I I 1 I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ---------------------- Reserved ------------------- 671 70 I I 71 I I 72 I r I 73 I I 174 751 I I I I I I I80 u ty I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 01:40PM 19/09/18 18/10/30 14196 NC Highway 226 North 14196 NC Hwy 226 N Exit Time/Date Permit Expiration Date Bakersville NC 28705 02:40PM 19/09/18 20/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Roger D Garland,14196 NC Hwy 226 N Bakersville NC 28705//828-688-3791/ Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenance 0 Facility Site Review 0 Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Linda S Wiggs Ds DWR/ARO WQ/828-296-4500 Ext.4653/ Signature of Management Q A Reviewer os_ Agency/Office/Phone and Fax Numbers Date 9/30/2019 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: D5274933-5A04-4CA2-8024-7DE4689083DA NPDES yr/mo/day Inspection Type (Cont.) NCG550105 I11 121 19/09/18 117 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The Inspector, Linda Wiggs, met with Mr. and Mrs. Garland. The system was installed in the late 1970's and consists of a septic tank and sandfilter under the front yard. Mr. Garland showed the Inspector what he believes to be the discharge pipe located in the middle of, and recessed into, the railroad ties retaining wall. Two black corrugated drainage type pipes were observed right at creek level; it is believed one may be the effluent, the other for drainage. Mr. Garland had his septic tank pumped out on 9/17/2019. Page# DocuSign Envelope ID: D5274933-5A04-4CA2-8024-7DE4689083DA Permit: NCG550105 Owner - Facility: 14196 NC Highway 226 North Inspection Date: 09/18/2019 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ 0 ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? ❑ ❑ 0 ❑ Is septic tank pumped on a schedule? 0 ❑ ❑ ❑ Are pumps or syphons operating properly? ❑ ❑ 0 ❑ Are high and low water alarms operating properly? ❑ ❑ 0 ❑ Comment: Pumped 9/17/2019. Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? ❑ ❑ 0 ❑ Is the distribution box level and watertight? ❑ ❑ 0 ❑ Is sand filter free of ponding? 0 ❑ ❑ ❑ Is the sand filter effluent re -circulated at a valid ratio? ❑ ❑ 0 ❑ # Is the sand filter surface free of algae or excessive vegetation? 0 ❑ ❑ ❑ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ 0 ❑ Comment: Yard did not indicate any issues but did have a couple of brown grass areas possibly from dry weather. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ Page# 3 DocuSign Envelope ID: D5274933-5A04-4CA2-8024-7DE4689083DA Permit: NCG550105 Inspection Date: 09/18/2019 Effluent Pipe If effluent (diffuser pipes are required) are they operating properly? Comment: See summary. Owner - Facility: 14196 NC Highway 226 North Inspection Type: Compliance Evaluation Yes No NA NE ❑ ❑ ■ ❑ Page#