Loading...
HomeMy WebLinkAboutSW3190901_DG_SALISBURY_21350_9/30/2019STORE #21350 VICINITY MAP (NTS) SURVEY: BLUE RIDGE GEOMATICS, PA 126 EXECUTIVE DRIVE - SUITE 220 WILKESBORO, NC 28697 LICENSE: C-3576 CITY/TOWN: SALISBURY, NC DEVELOPER: ENGINEER: BREC, PA 126 EXECUTIVE DRIVE - SUITE 220 WILKESBORO, NC 28697 LICENSE: C-3448 TERAMORE DEVELOPMENT, LLC PO BOX 6460 THOMASVILLE, GA 31758 NORTH CAROLINA COUNTY MAP C000 C001 C002 C003 C100 C200 C201 C202 C300 C301 C302 C400 G100 C900 C901 C902 C903 C904 (ROWAN COUNTY) SHEETINDEX COVER SHEET NPDES NCG01 EXISTING CONDITIONS DEMOLITION PLAN SITE PLAN GRADING PLAN PRE -CONSTRUCTION DA POST -CONSTRUCTION DA PHASE 1 ESC PLAN PHASE 2 ESC PLAN FINAL ESC PLAN UTILITY PLAN LANDSCAPE PLAN DETAILS DETAILS DETAILS DETAILS DETAILS SITE COORDINATES: LATITUDE = 35.625127' N LONGITUDE _-80.479130° W W w B EC Lu W a_ 0 ENGINEERING I PLANNING I ENVIRONMENTAL Q � v ) 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LLJ l\` s�iiirrrrr CARO ��''� Lij W Ess/ Lu _AL = pp U) U) 09/16/2019 Z Q J II Lu �. PO lq.. Q � NCBELSK-3448 i U) 2 �'• '• 0 ,'�• CARo •,` O 0 COVER SHEET PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS r PROVED BY: J.CHURCH SCALE: NTS (H) (V) SHEET: C000 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCGO1 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCGO1 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. Temporary and Permanent Groundcover* STABILIZATION TIMEFRAMES (Effective Aug. 3, 2011) SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS Perimeter dikes, swales, ditches, slopes 7 days None High Quality Water (HQW) Zones 7 days None \ Slopes steeper than 3:1 7 days If slopes are 10' or less in length and are than 2:1, 14 days I�u not steeper are allowed. Slopes 3:1 flatter 14 days 7 days for than 50' in length. or slopes greater All other areas with slopes flatter than 4:1 14 days None, except for perimeters and HOW Zones. *-For Falls Lake watershed, in disturbed areas where grading activities are incomplete, provide temporary groundcover no later than seven (7) days for slopes steeper than 3:1; ten (10) days for slopes equal to or flatter than 3:1; fourteen (14) days for areas with no slope. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: Temporary Stabilization Permanent Stabilization • Temporary grass seed covered with straw or • Permanent grass seed covered with straw or other mulches and tackifiers other mulches and tackifiers • Hydroseeding • Geotextile fabrics such as permanent soil • Rolled erosion control products with or without reinforcement matting temporary grass seed • Hydroseeding • Appropriately applied straw or other mulch • Shrubs or other permanent plantings covered • Plastic sheeting with mulch • Uniform and evenly distributed ground cover sufficient to restrain erosion • Structural methods such as concrete, asphalt or retainingwalls POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. nlI NORTH CAROLINA �, Environmental Quality EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number of waste containers on site to manage the quantity of waste produced. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. 8. Dispose waste off -site at an approved disposal facility. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER A -,o miNg ar rErvct es irvv, U�as,AF�Es D��aEaM 00O ��E RDrEP�s °` rvDrAPODE Oro oN �rvP��s"0 PDBEIII D 0 0 0 0 0 0 J0 SECTION BEILT A 0rE SANDBAGS srwvLE s P, -A oArorvoErERMrvEorvFE rvarirvc.VicEElis°xzaA SECTION A -A oa c �ALsocnriory oErEaMwEow EiE�o rvoTiNG OEvcE 1D85 ]a'pMrv� N. uoaEncH cE Mw11-u . wcHEs of EaEEsoARD. EEDS PLAN ""'n,Aa EODw1"G1= orn,w oEvcE. PLAN-I.S.DI SE. T. BB 'LEASKEo w�rH siaw,oE BELOW GRADE WASHOUT STRUCTURE ABOVE GRADE WASHOUT STRUCTURE CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary P g g p p Y products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF -INSPECTION Self -inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of greater than 1.0 inch occurs outside of normal business hours, the self -inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. Inspect Frequency Inspection records must include [40 CFR 122.41]: (during normal business hours (1) Rain Daily Daily rainfall amounts. gauge If no daily rain gauge observations are made during maintained in weekend or holiday periods, and no individual -day rainfall good working information is available, record the cumulative rain order measurement for those un-attended days (and this will determine if a site inspection is needed). Days on which no rainfall occurred shall be recorded as "zero." The permittee may use another rain -monitoring device approved by the Division. (2) E&SC At least once 1. Identification of the measures inspected, Measures per 7 calendar 2. Date and time of the inspection, days and within 3. Name of the perscn performing the inspection, 24 hours of a 4. Indication of whether the measures were operating rain event > 1.0 properly, inch in 24 5. Description of maintenance needs for the measure, hours 6. Corrective actions taken, and 7. Date of actions taken. (3) At least once 1. Identification of the discharge outfalls inspected, Stormwater per 7 calendar 2. Date and time of the inspection, discharge days and within 3. Name of the perscn performing the inspection, outfalls 24 hours of a 4. Evidence of indicators of stormwater pollution such as (SDOs) rain event > 1.0 oil sheen, floating or suspended solids or discoloration, inch in 24 S. Indication of visible sediment leaving the site, hours 6. Actions taken to correct/prevent sedimentation, and 7. Date of actions taken. (4) Perimeter At least once If visible sedimentation is found outside site limits, then a of site per 7 calendar record of the following shall be made: days and within 1. Actions taken to clean up or stabilize the sediment that 24 hours of a has left the site limits, rain event > 1.0 2. Date of actions taken, and inch in 24 3. An explanation as to the actions taken to control future hours releases. (5) Streams At least once If the stream or wetland has increased visible or wetlands per 7 calendar sedimentation or a stream has visible increased turbidity onsite or days and within from the construction activity, then a record of the offsite (where 24 hours of a following shall be made: accessible) rain event > 1.0 1. Evidence and actions taken to reduce sediment inch in 24 contributions, and hours 2. Records of the required reports to the appropriate Division Regional Office per Part III, Section C, Item 2 a of this permit of this permit. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. NORTH CAROLINA 'Environmental Quality PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be documented in the manner described: Item to Document Documentation Requirements (a) Each E&SC Measure has been installed Initial and date each E&SC Measure on a copy and does not significantly deviate from the of the approved E&SC Plan or complete, date locations, dimensions and relative and sign an inspection report that lists each elevations shown on the approved E&SC E&SC Measure shown on the approved E&SC Plan. Plan. This documentation is required upon the initial installation of the E&SC Measures or if the E&SC Measures are modified after initial installation. (b) A phase of grading has been Initial and date a copy of the approved E&SC completed. Plan or complete, date and sign an inspection report to indicate completion of the construction phase. (c) Ground cover is located and Initial and date a copy of the approved E&SC installed in accordance with the Plan or complete, date and sign an inspection approved E&SC Plan. report to indicate compliance with approved ground cover specifications. (d) The maintenance and repair Complete, date and sign an inspection report requirements for all E&SC Measures have been performed. (e) Corrective actions have been Initial and date a copy of the approved E&SC taken to E&SC Measures. Plan or complete, date and sign an inspection report to indicate the completion of the corrective action. 2. Additional Documentation In addition to the E&SC Plan documents above, the following items shall be kept on the site and available for agency inspectors at all times during normal business hours, unless the Division provides a site -specific exemption based on unique site conditions that make this requirement not practical: (a) This general permit as well as the certificate of coverage, after it is received. (b) Records of inspections made during the previous 30 days. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. (c) All data used to complete the Notice of Intent and older inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] EFFECTIVE: 03/01/19 PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that must be reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: • They are 25 gallons or more, • They are less than 25 gallons but cannot be cleaned up within 24 hours, • They cause sheen on surface waters (regardless of volume), or • They are within 100 feet of surface waters (regardless of volume). (a) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (b) Anticipated bypasses and unanticipated bypasses. (c) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at (800) 662-7956, (800) 858-0368 or (919) 733-3300. Occurrence Reporting Timeframes After Discovery) and Other Requirements (a) Visible • Within 24 hours, an oral or electronic notification. sediment • Within 7 calendardays, a report that contains a description of the deposition in a sediment and actions taken to address the cause of the deposition. stream or wetland Division staff may waive the requirement for a written report on a case -by -case basis. • If the stream is named on the NC 303( ) listlist as impaired for sediment - related causes, the permittee may be required to perform additional monitoring, inspections or apply more stringent practices if staff determine that additional requirements are needed to assure com liance with the federal or state impaired -waters conditions. (b) Oil spills and • Within 24 hours, an oral or electronic notification. The release of notification shall include information about the date, time, nature, hazardous volume and location of the spill or release. substances per Item 1(b)-(c) above (c) Anticipated • A report at least ten days before the date of the bypass, if bypasses [40 CFR possible, The report shall include an evaluation of the anticipated 122,41(m)(3)] qualityand effect of the bypass. (d) Unanticipated • Within 24 hours, an oral or electronic notification. bypasses [40 CFR • Within 7 calendardays, a report that includes an evaluation of 122,41(m)(3)] the quality and effect of the bypass. (e) Noncompliance • Within 24 hours, an oral or electronic notification. with the • Within 7 calendardays, a report that contains a description of the conditions of this noncompliance, and its causes; the period of noncompliance, permit that may including exact dates and times, and if the noncompliance has not endanger health or been corrected, the anticipated time noncompliance is expected to the continue; and steps taken or planned to reduce, eliminate, and environment[40 prevent reoccurrence of the noncompliance. [40 CFR 122.41(1)(6). CFR 122.41(I)(7)] • Division staff may waive the requirement for a written report on a case -by -case basis. NCGO1 SELF -INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 03/01/19 NPDES CONSTRUCTION GENERAL PERMIT - NCG 010000 ENTIRE PERMIT CAN BE FOUND AT: https://files.nc.gov/ncdeq/Energy%20Mineral%20and%2OLand%2OResourceslStormwaterlNCGO10000_Final_Permit_2019_04_01.pdf EROSION CONTROL CONTACT MARK ZEINER - (267) 261-6972 PROJECT MANAGER LU LU W B EC LU LU J C_ G O ��. ENGINEERING I PLANNING I ENVIRONMENTAL Q 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LLJ \\��tiilirrrr�� LU U CARP '''� LU OFESS/O'`�i� Ile LU �-s- C%) ::D U) 09/16/2019 Z Q J �� RqT •. ' •G `�' U NCBELSK-34481 U) i(� ••• •• Q % •� •.....•••�� O z ,�• dr'�. TH CARP %,. ����I��•1����,, O 0 NPDES NCGO1 PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: NTS (H) (V) SHEET: C001 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. GENERALNOTES 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS ASSOCIATED WITH RELOCATION. 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH RELOCATION SHALL BE INCLUDED IN THE BASE BID. 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. UTILITY GAS POLE /e VLV. /°� I I GAG I p —i p \ \ �\ ROAD RIW GAS GA _ ° p p \ LEGEND — — PROPERTY LINE too EXISTING CONTOURS row PROPOSED CONTOURS BUILDING SETBACK — — — — — — — — — LANDSCAPE BUFFER P EX. OVERHEAD ELECTRIC GAS EX. NATURAL GAS W EX. WATER FO EX. FIBER OPTICS ROAD RIW GAS GAs�cAs /° � I I GAs—GAS —cl�s— m I 2-GAS GAS GAS I I — GAS — GAS AS GAS �a VLV's \ GAG —GAS� I9 s as = GAs ,p —cas \_\ \ — ' ST ST �y _ EBAR OUND d\ d� NAI L FOUND o I 0 O I II la I �I itI W 3 a o I O II �w / °LL � iNp II I II I LL. 1 I 15" RCP INV=815.39' �I "15" RCP iINV=815.85' GAS —GAG —GSA- —� --- — Iv'45— GAS— GAGGAS— _ GAS= —GA= =GA� �(.•\G� GASH GAS =GA= =GAG= =ASS-�$� GAS— GAS— GAS 5=GAS =- V J= GAS— GAS— GAG— GAS— GAS— GAS ^`^ �G S-- GAs— GAS— GAG— GAG— GAS— GAS =GAS= G. GAS— G ' ��6A5�--V�AG= GAS— GAS —GAS— GAS— GAS— GAS— GAS EDGE OF PAVEMENT — — — — — — — — — — — — — — — — — — _ EDGE OF PAVEMENT \ �I�'' HPLIG ROAD (S.R. 2528) - 60' PUBLIC R1W SI NANGHT I I I o / / I ' IN ERSECfI N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG.# \ I N.C. GRID-NAD 83 1 \ N.C. RID- ��' PIPE FOUN[� 12" RCP I / 12" RCP \ N \ \ z' PIPE FOUND NV=816.06' \ \ 1 \ N=685,581.32' c5` N=685,791.51' � !NV=815.23' � I / � � E=1,�,721.22' - __-- — — ---— — I I -- --- _ N��' EDGE �FAV>�FNT \ EDGE OF PAVEMENT / I ------ — / / — _ __ _ _ _— ___ _ —_— _ _ _ _ ° F _ _ \ \ o �,. �_ �� ST i Fo Fo Fc Fo _ Fo — Fo Fo Fo / o \ I Fo Fo F=� F,:.- �6 —� Fo ° Fo FFo Fo — Fo — Fo �o F=— Fo — Fo Fo Fo w--aFo3 w o F° Fo Fo Fo _ co _ F° +cow Fo Fo Fo _ o �. I DROP INLET o a o — ro —�=� w o N, . _ I w — w — w— .,,y��' _ —w�` w — w — w — w — v�t �+n� w w w _ �.. w — Fo — RIM=812.02' ' _O — i w w w w w w w w / INV. IN=809.66' — — o.� =O •o �' ��/ w / / _ \\ \\\ — — J / — — — — — — — — — — — — y� UT CITY \ w — — — INV OUT=809. rFo eo / _ 6 ( \ — — Fo =� c Fo Fo — _ — — POLE _ _ I ° I/ / / / / — — — / — �-- � \(V FG — S48' 7�31� 01_ — — — — _ �� Fo F�,� _ p _ _ p _ p a o� Fo p _° S48° 25 26"E— FoIUTILIV(' / F° Fo F. F Fo Fo o —50 —Fo Fo Fo �o Fo \\ S ROAD RA8L — F. —p —ate �p p =p _ —o��r _ �Q ,�f -o / o ST / ST I— ST ST I— ST ST ST / \ PKE ro F�l�"� Fo w �� / p — p /— -� / \ — p p / p -1- p —/- p — p /pT p p Fo o — o Fo co Fo Fo Fo �- Fo Fo p / / \ \� p p °/ —p—p— oor UTILITY POLE �o /p/ 1Z / I / ° ;v ` pW`N / I \ �/ \ OBSERVED RI 14T�OF WAY / I W 1W l �� ROP / / R/V1� R/�AI/ R/VV, / R/W ?� RAN �, =; RNV RM R/W R/W/ R/W R/W R/W. RAN RAN RAN o w It It Is / 18'✓RCP / INVO10.05'I / o/ / / �%V I ' /,/ I X GATE E e I' / / REBFV SET ° RI / / I / GAS )- / / / / MTR.— — — — — — — — — — — — — -- EXISTING HOUSE It STEPS !!! I u�.. / l/ o / / I / 5/8" REBAR / FOUND / / / / / O / /UTILITY I / / / I 1 / PROPANE — POLE I / / / 30" I I / / / / TANK / /� I / / / / 0 O I° \ y / 1 I W3 // a 3 1 Irmo ° o < / / / /��/_ / _—� ���' OBDG ' / \ 3 — q — — — \ i / E.ZE OF GRAVEL / /e -- / / / -----�-- -✓---------- O {---------- ----------4-------------�------ ---- - ��- GRAVEL DRIVE TYJ785, F SALISBURY 7° t�---� ----- / ___ ____ \ \ l / �_ — f / / / _ \ D. PG. 108 ------------------------------------------------- -- ------------------- \ \ R EL —' _ \ _ EDGE OF G VEL\_ / / / / / / 00 \ OV�AN CO PARCEL �— _ _ / / / / // ID: 402 067 I I / %� — _— - — = _ _ _ / \ / / / / / ` — — — i LJSE: �UNICIPAL UTILI / _ I ' POL� ° / / / p �' I I UTILITY POLE 1/o aoI \\///' GG 1 / 1 00 / oo sHg6/ //// \\\\ B,IEB R 1 o SET\ v00 / WELL / /� &751 I100_ G13 I m l III l/ llll o z00 o 1 I 1 1 00 8" i3/4"/p �/ "S0 / / _00 — ----- I99FO/J �/1 / / / —-- — NAIL / /�� / / / / — X — —�L — / / — X X x 48° 58' 30"E_739$ X; X $4//° 50' 56"E FOUND III_ X ' _ X X X I GATE /I — � L X N48° 56' 52"W - 320.81 N X X X X X8' CHAIN LINK FENCE 4 x----� X X X z ��k — �4 — \ UTGILkIT 9 71 — _ — ; 8' CHAIN LINK FENCE I z" PIPE I Fnl1ND \ tt l ❑ IX ROWAN COUNTY Il— 1, ❑ I BOARD OF EDUCATION D.B. 623, PG. 343 ' ROWAN CO. PARCEL ID: 402 036 MULTIPLE USE: MUNICIPAL k TELEPHONE PEDESTALS AND VAULTSCOMMUNICATIONCONCRETE VAULTS ON CONCRETE I ! N.C. G,.' .... 1z" PIPE FOUND N=685,423.70' E=1,560,520.29' CITY OF SALISBURY D.B. 786, PG. 823 ROWAN CO. PARCEL ID: 402 068 USE: MUNICIPAL Lu w B EC � Lu J a_ O ENGINEERING I PLANNING I ENVIRONMENTAL Q U) 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LIJ \�\�\1111rrrr/� LLI U .� ,\H CAR % ' Lu oFEssLu Q� 9 :A = 00 5 —_ ` U) ccNGINE��-�G�: ::D 11111111\1`\ `� v ^ l 09/17/2019 Z • •• PO •• 0 RqT •. Q U � NCBELS#C-3448. U) ,'�• TH CARP♦ -' O 0 EXISTING CONCITIONS PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: 20 10 0 20 40 SHEET SIZE: 24" : DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: ill = 20' (`H/) (V) SHEET: C002 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. GENERALNOTES 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS ASSOCIATED WITH RELOCATION. 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH RELOCATION SHALL BE INCLUDED IN THE BASE BID. 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. UTILITY o GAS POLE /e . KI � VLVGAG GGSpt ROAD R/W — AG GAS _ GAs GAs cAs \ GAs cas _cas _cas _cas _ G m I v 2-GAS LEGEND — — PROPERTY LINE too EXISTING CONTOURS row PROPOSED CONTOURS BUILDING SETBACK — — — — — — — — — LANDSCAPE BUFFER P EX. OVERHEAD ELECTRIC GAS EX. NATURAL GAS W EX. WATER FO EX. FIBER OPTICS AREA TO BE REMOVED —ROAD R/W ' / I AS AS / GAS V V'S Gas �°� caste Fo S ASS GASH GAS F= I a �o cas GAS cas ST ST I \ N I GAS�GAS� GASH GASH GASH GAS— GAS—GYS—G�S— GAS— GAS— GAS —GAS— GAS— GAS —GAS— GAS —GAS —GA GAS— GAS—GAS— GAS— S—GAG— GAS— GAS— GAS— GAS — GAS— GAS— GAS —GAS— GAS— GAS— GAS— GAS — GAS— GAS— GAS— GAG— GAS— GAS— GAS— GAS — GAS— GAS— GAS— GAS— GAS— GAS— GAS— GAS— ' I ,� EDGE OF PAVEMENT EDGE OF PAVEMENT /SIG / / I \ �p I IN ER�fIH9N \ \ \ \ o I I I I I I Ni C. GRID-NAD 83 PIPE FOUND N=685,791.51' E=1,560,485 95' EDGE OF PAVEMENT I 12"RCP INV=815.23' —\ I NG / I DROP INLET RIM=812.02' INV. IN=8096' INV OUT=809.63 \ I -� a f o w I e° � F — Fo �Fo CFO �w Fo w wIS � Fo / o w �w �w _w —w �w s GAS VLV. T,^j § Zllo —v —v —v FO Fo Fo Fo Fo Fo Fo O Fo Fo FO IS Fo Fo F° �TILITY F. �Fo �\ °ST ST ST ST ST ST ST ST ST ST ° \ POLE F" FO — FO �' v— ° UTILITY POLE R/W R/W R/W R/W R/W �N � M � W -- _1I ?r GAS METER TO \ ' 18" RCP lo. ° \� 3 BE RELOCATED BAR UND o \ 11 I �1 I �I I �\ I I I W II NA I L FOUND II oLL II # ' II � I0 �I 6/ I I� � opl I II I II '~ I W o II � 3 a I O I° w II I oLL I II ID II I II I Is LL. 1 EXISTING RCP TO BE REMOVED 12" RCP INV=816.06' INV=810.05' 0 g' REBAR ' SET o RIB I GAS MTR. GAS VLV. E TING J 3 /WOOD a STEPS /1 /e 3 0 5/8" REBAR JUT a (FOUND 3 o EXISTING STRUCTURE /e ROPANE / PC Q m TO BE REMOVED rANK � 1 15" RCP W I e I I EXISTING RCP / 9 U INV=812.40' 3 ° °LL/ I TO BE REMOVEDco I 0 O~ 15" RCP I / � ' EDGE OF GRAVEL e /e � Q Q INV=812.65' � z \ I o I I Q UTILIT I J I POLE O 1lo POINT OF BEGINNING 3 0 N.C. GRID-NAD-83 g' REBAR SET N=685,749.00' 3 E=1,560,309.16 80' p/W ' I ° 1 °�I I 41 LL- °I a 0 AI o oII II3 I 41I I 0 1 °! I FOUNDS (NAIL II UTILIT S47° 50' 56"E FOUND 9. OLE 71' / ❑ r EDGE OF GRAVEL UTILITY a EXISTING UTILITY POLE TO POLE BE REMOVED/LRELOCATED EXISTING TREES TO BE REMOVED I � Q r^� V ZE co ca W Q HEILIG ROAD (S.R. 2528) - 60' PUBLIC R/W N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG. 509 EDGE OF GRAVEL UTILITY a EXISTING UTILITY POLE TO POLE BE REMOVED/LRELOCATED EXISTING TREES TO BE REMOVED I � Q r^� V ZE co ca W Q HEILIG ROAD (S.R. 2528) - 60' PUBLIC R/W N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG. 509 N.C. RID-NAD $7— ." PIPE FOUND N=685,581.32' E=1560,721.22' EDGE OF PAVEMENT — Fo � Fo � L'S Foy Fo � Fo � Fo � o F° Foy Fo— FO— Fo— FO— Foy Foy Fo Foy Fo— � FO �F. Fo— FG— Fo— Fo4—F � F Fo\ � F.Fo — Fo — Fo � w —w —w —w —w —w —w —w —w �w —w �w �w .w wFo— / w w wV•V °�UTILITY 3 w Fo° — S48° 18'27"E - 316.01 FG /POLE� Fo � 25' 26"E - 5 o — P Fo Fo FS48° o°o ROADR/W —, — — —v a—a—e—v—°—P—P Fo � FO — FO —e —` — —v Fo�Fo�Fo �Fo �Fo —v —e —e — w�'P —P o �Fo �. �- Fo —P —P —P — — —P —P —P — —�P —P —�•mc \ FO � F° OBSERVED RIG14Tf OF I w -WAY ww R/W R/W R/W R/W R/W R/W R/W R/W Fo / �. P�' 3 F x X GATE o 3 I EXISTING TREES TO 3 I BE REMOVED 3 � 1 1 EXISTING UTILITY POLE TO 3 � 1 1 1 J BE REMOVED/LRELOCATED 1 3 'Lu O / zLu 1 U w o Q 3 / 30" C 1 3 1 1 1 GG 3 / ' / 1 ' I � EXISTING TREES 3 1 1 TO REMAIN 3 TORA LID 1 O CITY OF SALISBURY D.B. 785, PG. 108 ROWAN CO. PARCEL 0o ID: 402 067 ! USE: MUNICIPAL EXISTING STRUCTURES TO BE REMOVED Q I ' 1 GG w 3 wo ' I w 1 I w 1 j EXISTING WELL TO 3 1 ' ' I BE ABANDONED A ' 00 SHED 8" REB SET ' 1 3 1 1 1 � 1 1 � WELL 1 � 1 3 ' � � 1 ' 3 1 1 1 1 I 1 1 1 � O 1 1 1 � I I 1 1 , , 00 ' � I 1 1 1 1 1 1 1 EXISTING TREESLo TO REMAIN co 1 1 00 1 I , � ' 1 3 1 1 1 w 1 1 1 1 ' r 111111/// 00 O I it 1 � 00 S48° 58' 30"E - 73.08' — Q X3 X X ^+ x x � x x z �� �� x x x x x x x x x I GATE ���� x x x x — x � — � �� — — x N48° 56' 52"W - 320.81' 8' CHAIN LINK FENCE 8' CHAIN LINK FENCE t! z" PIPE 1 J' I FOUND 1°I 1 I ❑ 1 ROWAN COUNTY 3 -�_� BOARD OF EDUCATION 15" RCP ° o '�- ❑ I �_ _1_ i D.B. 623, PG. 343 ROWAN CO. PARCEL ID: 402 036 ' INV 815.39' 13 y �3 MULTIPLE USE: MUNICIPAL 15" RCP ° INV=815.85' ° I k TELEPHONE PEDESTALS AND COMMUNICATION VAULTS ON CONCRETE N.C. GRID-NAD 83 1z' PIPE FOUND N=685,423.70' E=1,560,520.29' CITY OF SALISBURY D.B. 786, PG. 823 ROWAN CO. PARCEL ID: 402 068 USE: MUNICIPAL o� h� JAKEALEXANDER BLVD, S J � / P �o SITE S�cTTFRs ° Fliy VICINITY MAP (NTS) W w B EC � W a_ O U ENGINEERING I PLANNING I ENVIRONMENTAL Q 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LLJ \\ok11II1j/j � uj C) CAR Lu Lu A _ m ` U) ::D C\A U} 09/17/2019 Z Q • �. �� Po .� RqT •. Q U � NCBELS#C-3448. U) �%i �'• '• Q' : O ,'�• CARo •,` ���������HN�♦ O 0 DEMOLITION PLAN PREPARED FOR: TERAMORE DEVELOPMENT, LLC PO BOX 6460 THOMASVILLE, GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 20' (H) (V) 20 10 0 20 40 SHEET: C003 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE GENERALNOTES 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS ASSOCIATED WITH RELOCATION. 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH RELOCATION SHALL BE INCLUDED IN THE BASE BID. 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. DOLLAR GENERAL PAVEMENT NOTES: 1. DETAILS ARE DOLLAR GENERAL STANDARD REQUIREMENTS AND MAY INCREASE OR DECREASE WITH VARIOUS SOIL CONDITIONS. A GEO-TECHNICAL INVESTIGATION WITH PAVEMENT DESIGN RECOMMENDATIONS SHALL BE COMPLETED FOR EACH DEVELOPMENT. THE FOLLOWING DETAILS ARE MINIMUM DOLLAR GENERAL REQUIREMENTS. INCREASED RECOMMENDATIONS ARE TO BE USED. 2. THE SUBGRADE MATERIALS SHALL BE PROOF ROLLED AND/OR SCARIFIED AND COMPACTED PRIOR TO PLACEMENT OF BASE MATERIAL. WHERE EXISTING SUBGRADE MATERIALS ARE UNSUITABLE. THEY SHALL BE REMOVED AND REPLACED WITH COMPACTED SELECT MATERIAL IN ACCORDANCE WITH GEO-TECHNICAL RECOMMENDATIONS. 3. HEAVY DUTY CONCRETE PAVEMENT AND STANDARD DUTY CONCRETE PAVEMENT (AS RECOMMENDED BY GEO-TECHNICAL REPORT OR DOLLAR GENERAL MINIMUMS) SHALL BE STEEL REINFORCED. REINFORCEMENT TYPE SHALL BE PRIOR APPROVED BY DOLLAR GENERAL. 4. CONCRETE PAVEMENT PLAN SHALL BE PROVIDED TO DOLLAR GENERAL FOR PRIOR APPROVAL. ALL JOINTS MUST BE SEALED WITH AN APPROVED SEALANT. STEEL REINFORCING SHALL BE USED AT JOINTS. REFER TO ACI 330R (GUIDE FOR DESIGN AND CONSTRUCTION OF CONCRETE PARKING LOTS) FOR JOINT DESIGN AND LAYOUT. BAR UND I I I I NAI L FOUND 1 I o= 0 0 I 1 1 1 I U CO a 0� 3 , 5/8" REBAR W a (FOUND mco Q m z N a • � O O � w O � W fie I � a 0 ~ 0 Q o �z I O U O I U 0if, O I POINT OF BEGINNING N.C. GRID-NAD-83 g' REBAR SET iN=685,749.00' E=1,560,309.16' 1 ll 80, 4 1 PARKING AND PAVEMENT NOTES 1. ALL SIGNS, PAVEMENT MARKINGS, AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC DEVICES, 2012 EDITION AS AMENDED. 2. ALL PAVEMENT MARKINGS SHALL BE THERMOPLASTIC WHITE ON ASPHALT IN NCDOT ROW. 3. ALL DIMENSIONS ARE TO FACE -OF -CURB UNLESS INDICATED OTHERWISE. 4. ALL CURB RADII ARE 5' UNLESS OTHERWISE INDICATED. 5. CONTRACTOR SHALL FURNISH AND INSTALL PAVEMENT MARKINGS AS SHOWN ON THE PLANS. 6. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL SIGNS, PAVEMENT MARKINGS, AND OTHER TRAFFIC CONTROL DEVICES WITH OTHER CONTRACTORS ON SITE. 7. JOINTS OR SCORE MARKS ARE TO BE SHARP AND CLEAN WITHOUT SHOWING EDGES OF JOINTING TOOLS. 8. CONTRACTOR SHALL SAW -CUT TIE-INS AT EXISTING CURBS AS NECESSARY TO INSURE SMOOTH TRANSITIONS. CONTRACTOR SHALL SAW -CUT AND TRANSITION TO MEET EXISTING PAVEMENT AS NECESSARY AND AS DIRECTED BY INSPECTOR TO INSURE POSITIVE DRAINAGE (TYPICAL AT ALL INTERSECTIONS). 9. CONTRACTOR SHALL COMPLY WITH ALL PERTINENT PROVISIONS OF THE MANUAL OF ACCIDENT PREVENTION IN CONSTRUCTION" ISSUED BY AGC OF AMERICA, INC. AND THE HEALTH AND SAFETY REGULATIONS FOR CONSTRUCTION ISSUED BY THE US DEPARTMENT OF LABOR. 10. CONTRACTOR SHALL FULLY COMPLY WITH THE REQUIREMENTS OF THE SOILS ENGINEER. 11. ALL EXISTING ON -SITE STRUCTURES SHALL BE REMOVED PER LOCAL CODES AND DISPOSED OF OFF -SITE, INCLUDING ALL ATTACHED UTILITIES AND APPURTENANCES. ANY AND ALL WELLS ON -SITE SHALL BE IDENTIFIED TO THE ENGINEER BEFORE CONSTRUCTION AND CAPPED PER HIS INSTRUCTIONS. 12. ALL AREAS NOT IDENTIFIED AS STANDARD DUTY PAVING SHALL BE CONSTRUCTED AS HEAVY DUTY PAVING (SEE DETAILS FOR STANDARD AND HEAVY DUTY PAVING REQUIREMENTS). 13. ALL SIGNS, WHETHER FREE-STANDING OR ATTACHED REQUIRE SEPARATE APPLICATION FOR EACH INDIVIDUAL SIGN. ALL SIGNS SHALL MEET LOCAL REQUIREMENTS. A SIGN PERMIT IS REQUIRED PRIOR TO INSTALLATION OF ANY SIGN. N.C. GRID-NAD 83 1' PIPE FOUND N=685,791.51' E=1,560,485 95' EDGE OF PAVEMENT op S68 �OP� R/W / Rig g' RESER PYLON SIGN R 91 /M /_ // 14 / 1 1co 0 w� oQ �o Iz � 1 I I U ' W co OMI I I 1 9.22' 6' r; EDGE OF PAVEMENT 10' X 70' SIGHT TRIANGLE STRIPING LEGEND SURFACES SHOULD BE CLEAN, DRY AND METAL SURFACES FREE YELLOW CURBING AND BOLLARDS - OF HEAVY RUST. 2 COATS PARKING LOT SHERWIN WILLIAMS - KEM 4000 ACRYLIC ALKYD ENAMEL SAFETY YELLOW B55Y300 SURFACES SHOULD BE CLEAN, DRY. TOP COAT SHERWIN STRIPING - PARKING LOT WILLIAMS - PROMAR TRAFFIC MARKING PAINT YELLOW TM5495 SURFACES SHOULD BE CLEAN, DRY. TOP COAT SHERWIN HANDICAP STRIPING - PARKING LOT WILLIAMS - PROMAR TRAFFIC MARKING PAINT "H.C." BLUE HEILIG ROAD (S.R. 2528) - 60' PUBLIC RIW N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG. 509 50' TAPER OBSERVED RIGHT-OF-WAY RAN RAN RAN OTAK1r%ADr% r%l ITV T NCDOT PAVING SEE DET. 1/C901 SITE INFORMATION ZONING CBI ACREAGE 2.25± ACRES PARKING SPACES PROVIDED (9' x 20') 30 SPACES FLOOD ZONE X - PANEL 5668 3 EMPLOYEES MAX EMPLOYEES PER SHIFT HOURS OF SUN. - SAT.: OPERATION 8 AM - 10 PM IMPERVIOUS AREA 31,841 SQ.FT. IMPERVIOUS 32.52% PERCENTAGE EDGE OF PAVEMENT 24" STOP BAR - WHITE PER NCDOT STDS. 1205 DEPRESSED CURB SEE DET. 5/C901 RNV RAN PAVEMENT MARKINGS PER NCDOT STDS. 1205 r— — 4" DOUBLE YELLOW LINES o. �1N.. ` Q 5. Aco A ' • • W W m N I- 131' - 15' 46.5' 12' x 18' DUMPSTER ' ENCLOSURE WITH ul zl ' BOLLARDS SEE DET. 4/C901 1 SAND FILTER ND ' 1 ' O C 1 I 10'SETBACK 3/4" PIPE FOUND NAIL o0 S47° 50' 56"E FOUND — — — — �� — — X X — _ —� — X X X _ X X X x x z X X — z "� X X N48° 56' 52"W - 320.81' X8' CHAIN LINK FENCE g.71' / 8' CHAIN LINK FENCE z" PIPI / x ROWAN COUNTY I FOUN % I BOARD OF EDUCATION % x ROWAN CO. PARCEL ID: 402 036 i I USE: MUNICIPAL / I } 1 EDGE OF PAVEMENT 10' X 70' SIGHT TRIANGLE ROAD N.C. GRID-NAD 87 ." PIPE FOUND N=685,581.32' E=1560,721.22' — — — I S48 _ 1 1 - RAN RAN RAN RAN :77 I1 1 I1 I1 SEPTIC FIELD TO REMAIN 80 UNDISTURBED (TEMPORARY ' EXCLUSION FENCE SEE DET. 5/C904) 1" ' 1 I ' ' 1 1 CITY OF SALISBURY D.B. 785, PG. 108 ' ROWAN CO. PARCEL ID: 402 067 ' USE: MUNICIPAL � � 1 0ti bm� W REBAR I SET ' I 1 1 IN 1� 1 1 S48° 58' 30"E - 73.08' X X X N.C. GRID-NAD 83 1z" PIPE FOUND N=685,423.70' E=1,560,520.29' CITY OF SALISBURY D.B. 786, PG. 823 ROWAN CO. PARCEL ID: 402 068 USE: MUNICIPAL 1 X X X X X GATE G/ o� h� JAKEALEXANDER BLVD, S J o 1%b / P �•`��� O°moo yF'�/�R SITE �o S�cTTFRs O Fliy VICINITY MAP (NTS) LEGEND — — PROPERTY LINE 100EXISTING CONTOURS 10o PROPOSED CONTOURS BUILDING SETBACK — — — — — — — — — LANDSCAPE BUFFER P EX. OVERHEAD ELECTRIC GAS EX. NATURAL GAS W EX. WATER FO EX. FIBER OPTICS NCDOT PAVING STANDARD DUTY ASPHALT / HEAVY DUTY ASPHALT SIGN LEGEND 0 STOP R1-1 30"X30" Lu w B EC � Lu J a_ O ENGINEERING I PLANNING I ENVIRONMENTAL Q 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz W \����liiirrrr�� LLI U i CAR Lu Lu A _ m 5 —_ ` W ::D C\A U> 09/17/2019 Z Q • �• PO •• RqT •. Q : NCBELS#C-3448 * W �%i �'• '• Q' : •, ,Q ' •.....••'�� O z �•• ,'�• CARo •,` ���������HN�♦ O 0 SITE PLAN PREPARED FOR: TERAMORE DEVELOPMENT, LLC PO BOX 6460 THOMASVILLE, GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 20' (H) (V) 20 10 0 20 40 SHEET: C100 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE ABBREVATIONS TC TOP OF CURB BC BOTTOM OF CURB TOR TOP OF RAMP BOR BOTTOM OF RAMP TOW TOP OF WALL BOW BOTTOM OF WALL BOD BOTTOM OF DITCH HP HIGH POINT EX. TC EXISTING TOP OF CURB EX. BC EXISTING BOTTOM OF CURB EP EDGE OF PAVEMENT EC EDGE OF CONCRETE -0 10 0+00 85 84 83 m r- 82 0 z 81 80 79 DRIVEWAY PROFILE STATION 1+00 EXISTING GRADE -2% SLOPE -6.7 0 SLOPE PIPE 1 PROPOSED GRADE 2% SLOPE -0+10 0+00 1+00 50 40 30 20 10 00 790 -ROAD RIW i' ST ST EEEt�, _ EDGE OF PAVEMENT - - - - - - - - EDGE OF PAVEMENT - - - - - - - - - - HE;LIG ROAD (S.R. 2528) - 60' PUBLIC RfW N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG.# N.C. GRID -NAD 83 \ '\ \ N.C. RID-NAD $� \ 'PIPE FOUND, PIPE FOUND z �00N=685,581.32' ,\ E=1,560,4RF� - - 1 - CD- - - - E=1,560,721.22' EDGE F`PAVEf��FNT _ - _ _ \ / / - - - - - - _ _ - - - - O \ _ - - _ - _ - EDGE OF PAVEMENT - \ / / I DROP INLET i - - - - - - 1 I RIM=812.02' - ' 817 I / INV. IN=809.66' i-----j / _ --- --- I IN OUT=80�.63 / / / / / / - / - T - _ S48� 7' _ 316 01_ PIPE 1 - - = g - - - - - _ _ - J� \ S48° 25' 26"E- ` 820 ST ST ST ST - ST ST - ST ST - ST ST - ST - ST ST ' V�02 INV.816.75 /// = a1 INV.=817.50 CURB INLET / / / / � I / / SEE DET. 6/C901 / / OP R/W / R/�AI/ / R/W� / R/W RNV v / RMI OBE D�RIGHT-OF-WAYNRMI RMI RMI RAN RAN RAN RAN RAN OUTFALL -1 / / / I / 22 I / 18'✓RCP / / / / / / / ' c OUND / GENERAL NOTES GRADING NOTES 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 1. PROPOSED CONTOURS SHOWN ARE TOP OF FUTURE PAVING/GRAVEL IN AREAS TO RECEIVE PAVEMENT/GRAVEL AND 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. TOP OF TOPSOIL IN AREAS TO BE SEEDED AND/OR LANDSCAPED. 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 2. AREAS OUTSIDE OF THE PARKING LOT PERIMETERS SHOWN TO BE SEEDED AND/OR LANDSCAPED. 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS 3. CONTRACTOR SHALL NOTIFY AND COOPERATE WITH ALL UTILITY COMPANIES OR FIRMS HAVING FACILITIES ON OR ASSOCIATED WITH RELOCATION. ADJACENT TO THE SITE BEFORE DISTURBING, ALTERING, REMOVING, RELOCATING, ADJUSTING, OR CONNECTING TO 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND SAID FACILITIES. CONTRACTOR SHALL PAY ALL COSTS IN CONNECTION WITH ALTERATION OF OR RELOCATION OF WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH THE FACILITY. RELOCATION SHALL BE INCLUDED IN THE BASE BID. 4. ALL CATCH BASIN GRATE AND FRAMES ARE TO BE BY US FOUNDRY OR APPROVED EQUAL (U.O.N.) SEE 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR SPECIFICATIONS. COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. 5. ALL AREAS NOT COVERED BY BUILDING OR PAVING ARE TO BE GRASSED. 6. UNUSABLE EXCAVATED MATERIALS AND ALL WASTE RESULTING FROM CLEARING AND GRUBBING SHALL BE DISPOSED TO AN APPROVED OFF SITE LOCATION BY CONTRACTOR. 7. ALL EXCAVATING IS UNCLASSIFIED AND SHALL INCLUDE ALL MATERIALS ENCOUNTERED. 8. BEFORE ANY MACHINE WORK IS DONE, CONTRACTOR SHALL STAKE -OUT AND MARK OUT THE ITEMS ESTABLISHED BY THE SITE PLAN. CONTROL POINTS SHALL BE PRESERVED AT ALL TIMES DURING THE COURSE OF CONSTRUCTION. LACK OF PROPER WORKING POINTS AND GRADE STAKES MAY REQUIRE CESSATION OF OPERATIONS UNTIL SUCH POINTS AND GRADES HAVE BEEN PLACED TO THE OWNER'S SATISFACTION. 9. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EARTHWORK QUANTITIES. ENGINEER MAKES NO STATEMENT EITHER IMPLIED OR EXPRESSED REGARDING CUT/FILL QUANTITIES. 10. ALL CORRUGATED METAL PIPE IS TO BE ALUMINIZED OR APPROVED EQUAL WITH RE -ROLLED ENDS. ALL BANDS ARE TO BE HUGGER TYPE. 11. ALL STORM DRAINAGE PIPES SHALL HAVE 12" MINIMUM COVER. 11. ALL GROUND ELEVATIONS ADJACENT TO BUILDING STRUCTURES ARE TO BE A MINIMUM OF 6" BELOW THE FINISHED FLOOR ELEVATION. 12. ALL HDPE IS TO BE ADS N-12 ST IB DUAL WALL WITH WATER TIGHT JOINTS AND DUAL WALL FITTINGS OR APPROVED EQUAL. IN I 13. ALL PIPE LENGTHS GIVEN ARE TO THE CENTER OF STRUCTURES. I 14. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ANY BENCHMARKS SUPPLIED AS PART OF THESE PLANS. I 15. CONTRACTOR RESPONSIBLE FOR IDENTIFYING AND PERMITTING WASTE AND BORROW SITES AS NECESSARY. WASTE I I ' AND BORROW SITES MUST BE NCDEQ APPROVED LOCATIONS. 1 INV=p10.05 I REBAR/ SET / / b_ / I / GATE 83 1 I I / 23 . D P INLET -1 823.30 TC . R : 822.10 LEGEND - - PROPERTY LINE 100 EXISTING CONTOURS row PROPOSED CONTOURS - - BUILDING SETBACK - - - - - - - - - LANDSCAPE BUFFER P EX. OVERHEAD ELECTRIC GAS EX. NATURAL GAS W EX. WATER FO EX. FIBER OPTICS CU INLET 1 822.80 1 DPE INV OUT: 819.50 / / \ 1 I/ // STRUCTURE TABLE RIM : 821.60 G o _ _ `Ar's / STRUCTURE NAME DETAILS 15�DPE INV IN: 818.55 0 SETBACK / - - - - - I l / 15 IHDPE INV >: 8�5 w��ti4 ? o tc / L- I / ' RIM = 821.60 SEPTIC FIELD TO REMAIN I / CURB INLET - 1 INV IN = 818.55 UNDISTURBED (TEMPORARY ' I / INV OUT = 818.45' /823 \I � EXCLUSION FENCE SEE DET. 51C904) � / I RIM = 822.10' � - DROP INLET � DROP INLET - 1 SEE DET. 71C901 - - INV OUT = 819.50' ti' ) z3 ----- 1 \l RIM = 820.75' / � � OUTLET STRUCTURE , / I � / ' / INV OUT = 815.00 Lu 19/ 19/ / INV. = 818.00 I S PIPE TABLE -'� PIPE NAME SIZE LENGTH SLOPE Lj c O \/ / - - _ ' 1 OITY FSALISBURY PIPE 1 15 INCH CORRUGATED HDPE PIPE 74.16' 1.01% 0 O 1 1 I / Z m I 0 / 3 0 / 5/8" REBAR - W a / FOUND co / Qm / �o NAIL N / FOUND N 6 Q o¢ C. P ° °. ,. ° . ° 5 . / � - - D. . 785, PG. 108 - - ° \ // ' ROVyAN CO. PARCEL PIPE - 2 15 INCH CORRUGATED HDPE PIPE 185.91' 0.50% 4 �Dy p o / ° O \ // ID 402 067 /Z I _ SE: MUNICIPAL PIPE - 3 15 INCH CORRUGATED HDPE PIPE 77.49' 0.57% Al INV. - 814.50 o I° o ' \ / / PIPE - 4 15 INCH CORRUGATED HDPE PIPE 73.92' 0.65% O o / POIPiT OF BEGINNIN N.C. GRID-NAD-83 I / / / / / 1 / \ i / / -1.9% - Fe \ g' REBAR SET / / / / / \ i / / ` 8" ('tEBAR N=685,749.00' / E=1,560,309.16' / I // /� / i i ;` / i / / DOLLAR GENERAL' / / ' , - - - - - - SET\ 80' l / �o t °04 �•:- / 9,100 SQ.FT. / / L0 I //'1 F.F.E. = 824.50 / / / �o \ / I ,Q - TC \ / 8 - 6" ROOF DRAINS WITH SPLASHBLOCK SEE DET. 8/C902 / / / , . P 0.9%� LLJ ul SAND FILTER ul - / oe zl SEE DET. 3/C904 825 OUTLET STRUCTURE SEE DET. 2/C904 820 /' / / / / / O oo 10' SETBACK/ / / 8" 3/4" 4f' \ FOf�1M/ (NAIL ��O / - - - - - -- \ / 99 /`b oo -8° 58 30E=7398 I $4/I° 50' 56"E FOUND - - - - - - - x X �t - x - x x - - - x x x x x x x - X GATE z z � `�4 � x x �� x N48° 56' 52"W - 320.81' x8' CHAIN LINK FENCE x x x 9.71' - - - -� 8' CHAIN LINK FENCE ROWAN COUNTY / I BOARD OF EDUCATION D.B. 623, PG. 343 1"' RCP II / x ROWAN CO. PARCEL ID: 402 036 INV=815.39' / / I USE: MUNICIPAL 15"' RCP J I NV=815.85' \ / % I Il/Ii} t! z" PIPE FOUND N.C. GRID-NAD 83 ' 11" PIPE FOUND N=685,423.70' E=1,560,520.29' CITY OF SALISBURY ' D.B. 786, PG. 823 ' ROWAN CO. PARCEL ID: 402 068 ' USE: MUNICIPAL OUTLET PROTECTION TABLE OUTLET PIPE LA (FT) W, (FT) W2 (FT) DA (IN) NCDOT CLASS PIPE - 1 5 4.0 7.5 1.5 A PIPE - 4 5 4.0 7.5 1.5 A BEFORE YOU DIG! CALL 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAW! \ COORDINATE WITH NCDOT AND/OR LOCAL TRANSPORTATION \ AUTHORITY AND FOLLOW TRAFFIC MANAGEMENT PLAN FOR ALL WORK WITHIN AND ADJACENT TO PUBLIC RIGHT OF WAY. 20 10 0 Lu w B EC Lu Lu J a_ 0 ENGINEERING I PLANNING I ENVIRONMENTAL Q W 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LIJ LLI� '� Lu ON 9 ; Lu m 5 -_ ` W � cN .1`, /1/1I1I��\\`�� U} 09/17/2019 Z J ����'• •`��, �REC�•P'� �• P� •• J Q U : NCBELS#C-3448 * U) �%i •'• '• Q' : 0 ,'�• T , CAR o •,` �IIIIII046NN• O 0 GRADING PLAN PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: 20 40 r=77- 2::] DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 20' (H) 1 " = 20' (V) SHEET: C200 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. I Ale \� ROAD RM ROAD RM __---rs_� — --- ----__--___— -- — / - — — — — — EDGE OF PAVEMENT — — — — HEILIG ROAD (fir. . 2528) - 60' PUB �C RIVII / OLV PROPERTY LINE \ o. 4* DgSSO, \ 0 / ED E6F-PAYMENT F.j1GE OF PAVEMENT - • - - - - - - — J / =RQALRNV 1-1 ST S I ST ST ST ST ST f / I / / Q �\ \ / e _ _ Oaf GATE / i ---------/' I / �✓/ 1 I / / � , rl IIIGEOF�,R,AVEL____ Q / �c6� / GRAVEL IVE ) \ T / /_— / / — — — _ V / CITY-O SALISBURY LL/ a o 5 ti. — a` ------------- --- ----- ----�� ---------- t-- / / EDGEtCBAVELZ / i 1 D.J. 5,PG.108 Q 1 �`�1' I l ' / �l — r — — / — / / / / / / / / / — V \ / , BOVIANIC�O' PARCEL ID'//402067 �v/ 30 o ul Q �I jq 1 dj x — --x•;x �:�s� — x�� � —x � -�:! 8� !!AIN LINK FENCE C#1TE L x / �- / -, 8' CHAIN LINK FENCE / I~ ` � 1 ..Q�Q / of '�s ^b. , I /, El 1 �// 1 \ I CITY OF SP�LISBURY r 1 D.B. 785, G. 108 ROWAN COUNTY ROWAN C 067 L 60,, / / BOARD OF EDUCATION 1 V ID' 4 067 D.B. 623, PG. 343 1 \ 1 ROWAN CO. PARCEL ID: 402 036 /a CITY OF SALISBURY \ 1 D.B. PA ID: PG. A / 1 ROWAN CO. PARCEL IDS 402 068 / 1 \ POST CONSTRUCTION #1 I \\ / � 1 \ / I 1 ` \ 1 \ � 1 \ / 1 I 1 1 \ I 1 \\ / 1 / / / / / / / / / / / LEGEND — — PROPERTY LINE too EXISTING CONTOURS row PROPOSED CONTOURS BUILDING SETBACK — — — — — — — — — LANDSCAPE BUFFER P EX. OVERHEAD ELECTRIC GAS EX. NATURAL GAS W EX. WATER FO EX. FIBER OPTICS Lu w B EC � Lu J a_ O ENGINEERING I PLANNING I ENVIRONMENTAL Q 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LU \�\�\Ililrrrr�� LLI C) CAR ♦ '� Lu 9 Lu :A = 00 �� ::D cN�e.�`� lll111�\\\ (0 09/17/2019 Z J •• PD .• � Q IN BELS#C-3448 U) ,'�• CARo •,` O 0 PRE -CONSTRUCTION DA PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: 40 20 0 40 80 SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 40' (H) (V) SHEET: C201 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. 1 I \\\ ROAD RNV — — — — — — — — — — — — ROAD RM — — — I_—rs_� —_—--=---_--------- o---------- ' HEILIG ROAD ($rA. 2528) - 60' PUB 4C RIW .�� 8% / / / / �,'1n// / / / 1 GRID-NAD 83 1 o R/W / 'F�/W Pt R/V�1 I-P PIPE D I / 1 / 1 I S6$ / / / / _ / 822 N=685, 81.32'� / 8" REBAR -'�� � /GQ / / 820 I/ cAT FOUND I045 / �,� AR / � 1 V" % ✓ / I 823 POST CONSTRUCTION #1 r I / 1 3� o z �/ 1 0 J a // / / 1 . �. POST CONSTRUCTION #6 / CITY��SALISBURY A.• l `. j. / 4 ' 1 D. . 7 5, PG. 108 Q4•. t �• 1 r 10 ANJCCrPARCEL ID: 402 067 O \ 0 OW/��/ / / �/ // // �� --`BAR U 1 3 co SET P INT / POST CONSTRUCTION #3 / / o v / II 1 0 0l I// D / / / / / j � /� --� \ / I 0 z Q 7S 6 900, o 9. i �ul Lo I 1 /� ,� J�O cL0 cb`V� / / , / i — — — S48° 58 30 E - 73.08— — / _� S 56"E •O — 1: ' — f"_ x xTT FENCE N48' 56' 52"W - 320.81' 8' CHAIN LINK FENCE IPE N.C. � I x ` z GRID-NAD 83 I 1 FI U` 1z, PIPE \ 1 FOUND ' CITY OF SPLISBURY =1,56Q N 560520.29' ,423.70' o,� D.B. 785, G. 108 1o I ROWAN C . PARCEL \ / ROWAN COUNTY` RUCTION #4 POST CONST 60;R ID: 4 2 / / BOARD OF EDUCATION 1 / , 067 D.B. 623, PG. 343 y 1 / /• / / �/ r ROWAN CO. PARCEL ID: 402 036 1 `'o \ 1 CITY OF SALISBURY z^ PIPE 1 ROWD.B. 786, PG. 823 FOUND 1 AN CO. PARCEL ID: 402 068 I ^� �5 1 1 \ NCGS MONUMENT "COUNTY" 4 N.C. GRID-NAD-83 (2011) N=685,454.33' (OPUS) E=1,559,773.82' (OPUS) _� \ ELEV. = 817.51 1 1 \ 1 POST CONSTRUCTION #5 / ' 1 1 i 1 \ lip 1 I \ / / / / / / / / / / / / / / / / / LEGEND — — PROPERTY LINE 100EXISTING CONTOURS 10o PROPOSED CONTOURS _----- = BUILDING SETBACK LANDSCAPE BUFFER 0 GAS W F0 EX. OVERHEAD ELECTRIC EX. NATURAL GAS EX. WATER EX. FIBER OPTICS Lu w B EC � Lu a_ O ENGINEERING I PLANNING I ENVIRONMENTAL Q 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LLJ \�,��liiirrrr�� LLI U CAR % Lu Lu A _ m 5 —_ ` U) �/v . ccNGINE�R�G�� ::D cko c0 09/17/2019 Z U � NCBELS#C-3448. U) ,'�• CAPP •,` '",,t000 olll O 0 POST -CONSTRUCTION DA PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: F 40 20 0 40 80 SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 40' (H) (V) SHEET: C202 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. GENERALNOTES EROSION CONTROL CONSTRUCTION SEQUENCE STABILIZATION TIMEFRAMES 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 1. OBTAIN NECESSARY PERMITS FROM ALL REGULATORY AUTHORITIES. CONTRACTOR RESPONSIBLE FOR ALL SKIMMER BASIN CALCULATIONS 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. DEMO PERMITS AS WELL AS WASTE OR BORROW SITE SELECTION AND PERMITTING. 1. DA = 2.87ACRES SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 2. CONTRACTOR SHALL LOCATE ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION. SOFT DIG ALL 2. DU = 1.85 ACRES 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS UTILITIES WITHIN GRADING AREA TO IDENTIFY POTENTIAL CONFLICTS. 3. to = 5 minutes ASSOCIATED WITH RELOCATION. 3. STAKE -OUT ALL EROSION CONTROL MEASURES PRIOR TO CONSTRUCTION. n PERIMETER DIKES, SWALES, DITCHES, 7 DAYS NONE 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND 4. MAINTAIN NPDES TEMPORARY SEEDING SCHEDULE (SHEET C001) FOR ALL EXPOSED SOILS FOR THE DURATION 4. 1 = 7.0 hr SLOPES WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH OF CONSTRUCTION. 5. C = 0.6 RELOCATION SHALL BE INCLUDED IN THE BASE BID. 5. INSTALL PIPE - 1 WITH INLET & OUTLET PROTECTION. 6. Q10 = CiDA = (0.6)(7.0)(2.87) = 12.05 ft3/s 0� HIGH QUAILTY WATER (HQW) ZONES 7 DAYS NONE 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR 6. INSTALL TEMPORARY GRAVEL CONSTRUCTION ENTRANCE TO PROVIDE ACCESS FROM HEILIG ROAD. 7. SAreq = 325Q10 = (325)(12.05) = 3,917 ft2 COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. 7. INSTALL SILT FENCE AND STONE OUTLET(S) AT INDICATED AREAS. 8. Vreq = 1800DU = (1800)(1.85) = 3,330 ft3 9L: W - 3.0 IF SLOPES ARE 10' OR LESS IN . 8. INSTALL SKIMMER BASIN AND PERMANENT OUTLET CONTROL STRUCTURE WITH OUTLET PIPE. ATTACH SLOPES STEEPER THAN 3:1 7 DAYS LENGTH AND ARE NOT STEEPER MAINTENANCE PLAN FAIRCLOTH SKIMMER TO OUTLET CONTROL STRUCTURE WHILE BASIN IS USED AS SKIMMER. SKIMMER BASIN 10. depth= 3.0 THAN2:1, 14 DAYS AREA ALLOWED. 1. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY EXISTING BUILDING DEMOLITION. TO REMAIN IN PLACE UNTIL ALL AREAS HAVE BEEN ADEQUATELY STABILIZED AND APPROVAL TO REMOVE 11. SApvd = 4,107 ft 2. CONTRACTOR IS RESPONSIBLE FOR ALL EROSION AND SEDIMENTATION CONTROL REQUIREMENTS AND SHALL 12. V = 9,801 ft 7 DAYS FOR SLOPES GREATER MEASURE HAS BEEN RECEIVED BY ROWAN COUNTY EROSION CONTROL. pad � SLOPES 3:1 OR FLATTER 14 DAYS THAN 50' LENGTH COMPLY WITH THE LATEST EDITION OF THE NORTH CAROLINA EROSION AND SEDIMENTATION CONTROL 9. INSTALL TEMPORARY DIVERSIONS TO CONVEY RUNOFF TO SKIMMER BASIN. MODIFY TEMPORARY DIVERSIONS 13. LWEIR = 29 MANUAL. AS NEEDED DURING GRADING OPERATIONS TO ENSURE CONSTRUCTION RUNOFF IS DIRECTED TO SKIMMER 14, V@top2ft 8,288ft3 3. PER NPDES REQUIREMENTS, CHECK ALL EROSION AND SEDIMENTATION CONTROL DEVICES AND STORMWATER 15. Tdew,,ter 3 days ALL OTHER AREAS WITH SLOPES NONE, EXCEPT FOR PERIMETERS BASIN WITH POSITIVE DRAINAGE. � FLATTER THAN 4:1 14 DAYS AND HQW ZONES RUNOFF DISCHARGES FROM EACH OUTFALL SHOULD BE INSPECTED EVERY SEVEN DAYS AND WITHIN 24 HOURS 10. REMOVE EXISTING VEGETATION WITHIN GRADING LIMITS AND DISPOSE AT AN APPROVED SITE. 16. Qdewater = V@ top 2VTdew,,ter 2,762 ft3/d AFTER ANY STORM EVENT. A RAINFALL GAUGE SHALL BE KEPT ON SITE, AND A RECORD OF RAINFALL AMOUNTS 11. INSTALL PIPE NETWORK WITH INLET AND OUTLET PROTECTION. PIPE NETWORK MUST DISCHARGE TO SKIMMER SEE SHEET C001 FOR COMPLETE NDPES PERMIT INFORMATION AND DATES MUST BE RECORDED AND KEPT ON SITE. RECORDS OF INSPECTIONS OF DEVICES AND OUTFALLS BASIN DURING CONSTRUCTION ACTIVITIES. SHOULD BE KEPT AND VISIBLE SEDIMENTATION OUTSIDE THE DISTURBED LIMITS SHOULD BE NOTED. ANY 12. INSTALL ALL UNDERGROUND UTILITIES. ANY RUNOFF COLLECTED IN UTILITY TRENCHES MUST BE DEWATERED ACTIONS TO CONTROL FUTURE RELEASES AND CLEANUP OF SEDIMENT MUST BE RECORDED. A SAMPLE LOG TO THE SKIMMER BASIN. FOR RECORD KEEPING IS AVAILABLE FROM NCDEQ DIVISION OF WATER QUALITY, STORMWATER AND GENERAL 13. AFTER GRADING REACHES SUBGRADE ELEVATIONS, INSTALL STONE BASE IN PARKING AND BUILDING PAD PERMITS UNIT. AREAS TO PROTECT EXPOSED SOILS. 4. CHECK ALL EROSION CONTROL DEVICES WEEKLY AND AFTER EACH RUNOFF PRODUCING STORM EVENT AND 14. COORDINATE WITH NCDOT TO IMPLEMENT TRAFFIC CONTROL PLAN FOR CONSTRUCTION OF RIGHT TURN MAKE ANY NECESSARY REPAIRS AS NEEDED TO ENSURE DEVICES ARE FUNCTIONING AS INTENDED. TAPER. 5. REMOVE SEDIMENT DEPOSITS FROM SILT FENCE AND STONE OUTLETS WHEN DEPOSITS REACH HALF 15. STABILIZE ALL EXPOSED SOILS WITH SEEDING OR PERMANENT LANDSCAPING. CAPACITY, REPAIR ANY BREAKS IMMEDIATELY. 16. AFTER SITE STABILIZATION AND APPROVAL BY ROWAN COUNTY EROSION CONTROL, REMOVE SKIMMER BASIN 6. REPLACE GRAVEL CONSTRUCTION ENTRANCE AS NECESSARY. TO COMPLETE CONVERSION TO PERMANENT SAND FILTER FOR POST CONSTRUCTION STORMWATER CONTROL 7. CONTRACTOR WILL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALL FINES LEVIED DUE TO NOT MAINTAINING AND COMPLETE FINE GRADING. DO NOT ALLOW DISCHARGE INTO SAND FILTER UNTIL SITE IS COMPLETELY ROAD R/W PROPER EROSION CONTROL MEASURES AT ALL TIMES. STABILIZED. - - - - - - - - - - - - - - - - - - - - - �J/ N 17. INSTALL REMAINING PERMANENT LANDSCAPING. ' 18. REMOVE REMAINING EROSION CONTROL MEASURES AFTER RELEASE BY PERMITTING AUTHORITIES. ST ST MMMM;7, EUGE OF PAVEMENT _ - - - - _ - - - _ - - - - - EDGE OF PAVEMENT - - - - / HE;LIG ROAD (S.R. 2528) - 60' PUBLIC R1W / N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG. / J / TEMPORARY N.C. GRID -Pleb 83 DITCH TO BE LINED CONSTRUCTION 1 N.C. RID-NAD $� 1" PIPE FOUND, ` DITCH TO BE LINED \ o ENTRANCE SEE " PIPE FOUND \ �� WITH CURLEX II N 2 / I F c l N=685,791.51' \ °O DET. 1/C902 WITH CURLEX II N=685,581.32' E=1,560,48595' - 1 - - \ I PI AV�FNT E=1,560,721.22' EDGE OF PAVEMENT 817 DROP INLET - - - - I - - - - v� RIM=812.02' LIMITS OF ��� - - ----- -- \ 1 / 1 INV. IN=809.66' - - - - zzzz `INV OUT=809.63 _ - - - \ 1 DISTURBANCE / - - s ° 18' 27"E-31 - - _ _ - - - - - - - - PIPE 1 S48° 25' 26"E - 1 2.33± ACRES 1#- \ J � 1 ST ST ` ST ST ST ST ST ST ST ST ST ST ST 6 / / INV. = 816.75 INV. = 817.50 I o / / / / OBIkRVED RIGHT-OF-WAY000 i Lx //R/WMI - R/W R' RM1 T RAN RAN RAN RM ,RAN RAN RAN RAN MI �� RAN R/18'✓RCPEBAR - I / NV�810.05'I // GATE OUND / �" REBAR / TEMPORARY INLET I SET / Q1 PROTECTION SIEE 01 �- DET.5/C902 011�0ia0i �- 1�- l�0io- _L TEMPORARY 18" CMlP' STONE OUTLET / / - - 7' LA x 9' W2 SEE DET. 6/C902 / / / 1 TEMPORARY OUTLET o� h� JAKEALEXANDER BLVD, S J � 1%b / P , �� moo. �•`��� O°moo yF'�/�R �o SITE S�cTTFRs O Fliy VICINITY MAP (NTS) LEGEND 100 P GAS W - FO PROPERTY LINE EXISTING CONTOURS PROPOSED CONTOURS BUILDING SETBACK LANDSCAPE BUFFER EX. OVERHEAD ELECTRIC EX. NATURAL GAS EX. WATER EX. FIBER OPTICS SILT FENCE TEMPORARY DIVERSION LIMITS OF DISTURBANCE RIPRAP INLET PROTECTION OUTLET PROTECTION HARDWARE CLOTH INLET PROTECTION cZ it TEMPORARY DIVERSION �-� PROTECTION SEE / / \ STRUCTURE TABLE (ENSURE POSITIVE DET. 7/C902 STRUCTURE NAME DETAILS DRAINAGE) SEE DET. 3/C902 a _ / i2 / L- I o I / RIM = 821.60 _0 / / /� / / - SEPTIC FIELD TO REMAIN CURB INLET - 1 INV IN = 818.55' / UNDISTURBED TEMPORARY INV OUT = 818.45' I / 3 � / 518" REBAR I � / � o / � �} I / - / I / a / FOUND I / / N / / \I / / / / / / / EXCLUSION FENCE(SEE DET. 5/C904) - I // co cz� co RIM = 822.10' Q / f - / / DROP INLET - 1 o SILT FENCE W I / / / / //\\// INV OUT = 819.50, NAIL o / SEE DET. 2/C902 a / / / / / - RIM - 820.75' FOUND r, / / / / / OUTLET STRUCTURE INV OUT = 815.00 PIPE TABLE ' o / PIPE NAME SIZE LENGTH SLOPE do PIPE- 1 15 INCH CORRUGATED HDPE PIPE 74.16' 1.01% / OITY C�F SALISBURY D.g. 785, PG. 108 ROVyAN CO. PARCEL PIPE 2 15 INCH CORRUGATED HDPE PIPE 185.91' 0.50% O �� - ��� / / /��� oo ��` OE: ID-402067 //// MUNICIPAL PIPE 3 15 INCH CORRUGATED HDPE PIPE 77.49' 0.57% ' 0 INV. = 814.50 I I / , / I / / / / / / �' - , \ / / PIPE 4 15 INCH CORRUGATED HDPE PIPE 73.92' 0.65% o oo POINT OF BEGINNING / / /1 / - / / N.C. GRID-NAD-83 g' REBAR SET / E=1,560,309.16' � / / \ 00 8" I''tEBAR / v SET l i 0 40'W x 150' L x 3' D SKIMMER BASIN 2.0" FAIRCLOTH SKIMMER o WITH 1.8" KNOCKOUT ORIFICE SEE DET. 1-2/C903 191 SILT FENCE \/ SEE DET. 2/C902 I N oOr ND OUTLET STRUCTURE SEE DET. 2/C904 / / / B1B 00 �/ �n�0/ o0 1 \ / J \ 314'/P cL0 / - - ----- / FOh � / NAIL / / / / / / 4 ° 0, L J - - - - / 99 - - _ �-� F _ X GATE X X X 8' CHAIN LINK E ` v X 1 8' CHAIN LINK FENCE z PIPE ' I 9.71----'T / / l � Vx ROWAN COUNTY FOUND BOARD OF EDUCATION N.C. GRID-NAD 83 \ l� I D.B. 623, PG. 343 ' 1z PIPE FOUND \ 15" RCP x ROWAN CO. PARCEL ID: 402 036 N=685,423.70' II / \ INV=815.39' / / I H / I / USE: MUNICIPAL E=1,560,520.29' \ 15" RCP CI 85' / �, \ x ' D.BTY . Y 786, PG 823\ ROWAN CO. PARCEL ID: 402 068 \ USE: MUNICIPAL \ OUTLET PROTECTION TABLE OUTLET PIPE LA (FT) W1(FT) W2 (FT) DA (IN) NCDOT CLASS PIPE-1 5 4.0 7.5 1.5 A PIPE - 4 5 4.0 7.5 1.5 A BEFORE YOU DIG! CALL 1-800-632-4949 N.C. ONE -CALL CENTER ITS THE LAW! COORDINATE WITH NCDOT AND/OR LOCAL TRANSPORTATION AUTHORITY AND FOLLOW TRAFFIC MANAGEMENT PLAN FOR ALL WORK WITHIN AND ADJACENT TO PUBLIC RIGHT OF WAY. LU w B EC LU LU a_ 0 ENGINEERING I PLANNING I ENVIRONMENTAL 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz W > \���11111rrrr�2 LLI U i CAR LU LU A _ m - 5 -_ C0 ::D 09/17/2019 Z Q J LU �� RqT •. U : NCBELS#C-3448 * U) ,'�• TH CAPP •,` O 0 PHASE 1 ESC PLAN PREPARED FOR: TERAMORE DEVELOPMENT, LLC PO BOX 6460 THOMASVILLE, GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 20' (H) (V) 20 10 0 20 40 SHEET: C300 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE GENERAL NOTES EROSION CONTROL CONSTRUCTION SEQUENCE 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 1. OBTAIN NECESSARY PERMITS FROM ALL REGULATORY AUTHORITIES. CONTRACTOR RESPONSIBLE FOR ALL 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. DEMO PERMITS AS WELL AS WASTE OR BORROW SITE SELECTION AND PERMITTING. 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 2. CONTRACTOR SHALL LOCATE ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION. SOFT DIG ALL 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS UTILITIES WITHIN GRADING AREA TO IDENTIFY POTENTIAL CONFLICTS. ASSOCIATED WITH RELOCATION. 3. STAKE -OUT ALL EROSION CONTROL MEASURES PRIOR TO CONSTRUCTION. 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND 4. MAINTAIN NPDES TEMPORARY SEEDING SCHEDULE (SHEET C001) FOR ALL EXPOSED SOILS FOR THE DURATION WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH OF CONSTRUCTION. RELOCATION SHALL BE INCLUDED IN THE BASE BID. 5. INSTALL PIPE - 1 WITH INLET & OUTLET PROTECTION. 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR 6. INSTALL TEMPORARY GRAVEL CONSTRUCTION ENTRANCE TO PROVIDE ACCESS FROM HEILIG ROAD. COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. 7. INSTALL SILT FENCE AND STONE OUTLET(S) AT INDICATED AREAS. 8. INSTALL SKIMMER BASIN AND PERMANENT OUTLET CONTROL STRUCTURE WITH OUTLET PIPE. ATTACH MAINTENANCE PLAN FAIRCLOTH SKIMMER TO OUTLET CONTROL STRUCTURE WHILE BASIN IS USED AS SKIMMER. SKIMMER BASIN 1. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY EXISTING BUILDING DEMOLITION. TO REMAIN IN PLACE UNTIL ALL AREAS HAVE BEEN ADEQUATELY STABILIZED AND APPROVAL TO REMOVE 2. CONTRACTOR IS RESPONSIBLE FOR ALL EROSION AND SEDIMENTATION CONTROL REQUIREMENTS AND SHALL MEASURE HAS BEEN RECEIVED BY ROWAN COUNTY EROSION CONTROL. COMPLY WITH THE LATEST EDITION OF THE NORTH CAROLINA EROSION AND SEDIMENTATION CONTROL 9. INSTALL TEMPORARY DIVERSIONS TO CONVEY RUNOFF TO SKIMMER BASIN. MODIFY TEMPORARY DIVERSIONS MANUAL. AS NEEDED DURING GRADING OPERATIONS TO ENSURE CONSTRUCTION RUNOFF IS DIRECTED TO SKIMMER 3. PER NPDES REQUIREMENTS, CHECK ALL EROSION AND SEDIMENTATION CONTROL DEVICES AND STORMWATER BASIN WITH POSITIVE DRAINAGE. RUNOFF DISCHARGES FROM EACH OUTFALL SHOULD BE INSPECTED EVERY SEVEN DAYS AND WITHIN 24 HOURS 10. REMOVE EXISTING VEGETATION WITHIN GRADING LIMITS AND DISPOSE AT AN APPROVED SITE. AFTER ANY STORM EVENT. A RAINFALL GAUGE SHALL BE KEPT ON SITE, AND A RECORD OF RAINFALL AMOUNTS 11. INSTALL PIPE NETWORK WITH INLET AND OUTLET PROTECTION. PIPE NETWORK MUST DISCHARGE TO SKIMMER AND DATES MUST BE RECORDED AND KEPT ON SITE. RECORDS OF INSPECTIONS OF DEVICES AND OUTFALLS BASIN DURING CONSTRUCTION ACTIVITIES. SHOULD BE KEPT AND VISIBLE SEDIMENTATION OUTSIDE THE DISTURBED LIMITS SHOULD BE NOTED. ANY 12. INSTALL ALL UNDERGROUND UTILITIES. ANY RUNOFF COLLECTED IN UTILITY TRENCHES MUST BE DEWATERED ACTIONS TO CONTROL FUTURE RELEASES AND CLEANUP OF SEDIMENT MUST BE RECORDED. A SAMPLE LOG TO THE SKIMMER BASIN. FOR RECORD KEEPING IS AVAILABLE FROM NCDEQ DIVISION OF WATER QUALITY, STORMWATER AND GENERAL 13. AFTER GRADING REACHES SUBGRADE ELEVATIONS, INSTALL STONE BASE IN PARKING AND BUILDING PAD PERMITS UNIT. AREAS TO PROTECT EXPOSED SOILS. 4. CHECK ALL EROSION CONTROL DEVICES WEEKLY AND AFTER EACH RUNOFF PRODUCING STORM EVENT AND 14. COORDINATE WITH NCDOT TO IMPLEMENT TRAFFIC CONTROL PLAN FOR CONSTRUCTION OF RIGHT TURN MAKE ANY NECESSARY REPAIRS AS NEEDED TO ENSURE DEVICES ARE FUNCTIONING AS INTENDED. TAPER. 5. REMOVE SEDIMENT DEPOSITS FROM SILT FENCE AND STONE OUTLETS WHEN DEPOSITS REACH HALF 15. STABILIZE ALL EXPOSED SOILS WITH SEEDING OR PERMANENT LANDSCAPING. CAPACITY, REPAIR ANY BREAKS IMMEDIATELY. 16. AFTER SITE STABILIZATION AND APPROVAL BY ROWAN COUNTY EROSION CONTROL, REMOVE SKIMMER BASIN 6. REPLACE GRAVEL CONSTRUCTION ENTRANCE AS NECESSARY. TO COMPLETE CONVERSION TO PERMANENT SAND FILTER FOR POST CONSTRUCTION STORMWATER CONTROL 7. CONTRACTOR WILL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALL FINES LEVIED DUE TO NOT MAINTAINING AND COMPLETE FINE GRADING. DO NOT ALLOW DISCHARGE INTO SAND FILTER UNTIL SITE IS COMPLETELY PROPER EROSION CONTROL MEASURES AT ALL TIMES. STABILIZED. - �J/ N 17. INSTALL REMAINING PERMANENT LANDSCAPING. ' 18. REMOVE REMAINING EROSION CONTROL MEASURES AFTER RELEASE BY PERMITTING AUTHORITIES. EUGE OF PAVEMENT - - - - N.C. GRID -NeD 83 J\ 11 DITCH TO BE LINED PIPE FOUNB Cal N=685,791.51' \ \ WITH CURLER II E=1,560,485 95' EDGE `1'AVEFNT / / I DROP INLET- ( RIM=812.02' LIMITS OF- 1 / I INV. IN=809.66' SKIMMER BASIN CALCULATIONS 1. DA = 2.87ACRES 2. DU = 1.85 ACRES 3. t, = 5 minutes 4. i = 7.0 hr 5. C = 0.6 6. Q10 = CiDA = (0.6) (7.0) (2.87) = 12.05 ft3/s 7. SAreq = 325Q10 = (325) (12.05) = 3,917 ft2 8. Vreq = 1800DU = (1800)(1.85) = 3,330 ft3 9. L: W = 3.0 10. depth = 3.0 11. SApvd = 4,107 ft 12. Vpva 9,801 ft3 13. LWEIR = 29' 14, V@top 2 ft 8,288 ft3 15. Tdew,,ter 3 days 16. Qde.ter = V @ top 2 ff T dew,,ter 2,762 fh3/d STABILIZATION TIMEFRAMES SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES, SLOPES 7 DAYS NONE 0� HIGH QUAILTY WATER (HQW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS AREA ALLOWED. SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES GREATER THAN 50' LENGTH ALL OTHER AREAS WITH SLOPES NONE, EXCEPT FOR PERIMETERS FLATTER THAN 4:1 14 DAYS AND HQW ZONES SEE SHEET C001 FOR COMPLETE NDPES PERMIT INFORMATION ROAD R/W i' ST ST �j - - - - - _ - - - - EDGE OF PAVEMENT - - - - - - - HEiLIG ROAD (S.R. 2528) - 60' PUBLIC RM / N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG. 5�� / �/ TEMPORARY CONSTRUCTION N.C. RID-NAD $� N ENTRANCE SEE DITCH TO BE LINED \ z' PIPE FOUND co - -RI Fy 11 � 818 I `INV OUT-80�.63 DISTURBANCE / _ # �� s ° 1827�31 - - \ 1 1 2.33± ACRES / _ _ - _ / ST ST ` ST ST ST ST ST ST ST ST ST ST ST r1NV. =816.75 y � o / / OBIIkRVED RIGHT-OF-WAY / R/ R/�AI/ R/W, R/W RAN v ' RAN T RAN RAN RAN 18'✓RCP / :-:BAR - I / INVO10.05' 1 )UND / REBP,R/ I SET / ' STONE OUTLET Z SEE DET. 6/C902 / �/ / r PIPE -2 / _J / // / CUf B INLET -1 / RIM : 821.60 9x / - 1 �' 15"I0 INV IN: 818.55 / / i2 // / // / 15"IHDPE INV OUT: 818.45 E=1560 DGE OF PAVEMENT U/ ■ /•: 0 if INV. = 817.50 RM RM RM RM RM / a I / GATE N 00 I I / D P INLET -1 R :822.10 o� h� JAKEALEXANDER BLVD, S J � / P �•`��� O°moo yF'�/�R SITE �o S�cTTFRs O Fliy VICINITY MAP (NTS) LEGEND 100 P GAS W FO PROPERTY LINE EXISTING CONTOURS PROPOSED CONTOURS BUILDING SETBACK LANDSCAPE BUFFER EX. OVERHEAD ELECTRIC EX. NATURAL GAS EX. WATER EX. FIBER OPTICS SILT FENCE TEMPORARY DIVERSION LIMITS OF DISTURBANCE RIPRAP INLET PROTECTION OUTLET PROTECTION HARDWARE CLOTH INLET PROTECTION 1 " DPE INV OUT: 819.50 / I I/ / STRUCTURE TABLE `A�'s l STRUCTURE NAME DETAILS RIM = 821.60' o 0 1 / - / SEPTIC FIELD TO REMAIN I I / CURB INLET - 1 INV IN = 818.55' / LUa // 518 FOUND J I// / / M / UNDISTURBED (TEMPORARY I / INV OUT = 818.45' / I REBAR I w� EXCLUSION FENCE SEE DET. 5/C904) CO m / / W I w`� / Q 823 / / / I / DROP INLET - 1 RIM = 822.10' o SILT FENCE / / / INLET PROTECTION I \ INV OUT = 819.50' / / TYP. AT ALL INLETS NAIL o / SEE DET. 2/C902 I / // / 823 SEE DET. 4/C902 ) \ RIM = 820.75' FOUND ; / o / / OUTLET STRUCTURE INV OUT = 815.00 y I / INV. = 818.00 PIPE TABLE PIPE NAME SIZE LENGTH SLOPE o z I l / / ) l DITCH TO BE LINED - - - _ _ ViTYC�FSALISBURY PIPE 1 15 INCH CORRUGATED HDPE PIPE 74.16' 1.01% - D.g. 785, PG. 108 WITH CURLEX II ROVyAN CO. PARCEL PIPE - 2 15 INCH CORRUGATED HDPE PIPE 185.91' 0.50% HARDWOOD OE: ID: 402 067 .I--_------\ MUNICIPAL PIPE - 3 15 INCH CORRUGATED HDPE PIPE 77.49' 0.57% / - \ ' 0 INV. = 814.50 / / / 11 PIPE - 4 15 INCH CORRUGATED HDPE PIPE 73.92' 0.65% � 1 / / / I I / - 1 \ / / 0 I /� 1 _ / Q I \ / if I / - / / \ / 00 - if POINT OF BEGINNING 1 / / / k / / / ' - - g' REBAR SET / / / / / ` \ / N=685,749.00' 8SET\ \I EBAR / E=1,560,309.16' I / // \ / I / '--- \� / 80, q, ^ 40'W x 150' L x 3' D- / I Q \ SKIMMER BASIN I \ / 2.0" FAIRCLOTH SKIMMER o / WITH 1.8" KNOCKOUT ORIFICE SEE DET. 1-2/C903 SILT FENCE \/ w / / / / SEE DET. 2/C902 N co if 0 /// / \ ND OUTLET STRUCTURE SEE DET. 2/C904 / X / DITCH TO BE LINED g18 / / WITH CURLEX 11 FOf�J NAIL / _ - _ _ �. 4//° 50' 56 F N � X - x ��■ � �, ���F � � . z �t � --W' 51 ' X � } 8' CHAIN LINK FENCE 9.714 8' CHAIN LINK FENCE z PIPI ' 1 Vx ROWAN COUNTY FOUN / I BOARD OF EDUCATION I I /� D.B. 623, PG. 343 15" RCP II / x ROWAN CO. PARCEL ID: 402 036 INV=815.39' II / / �� USE: MUNICIPAL 15" RCP NV=815.85' \ N.C. GRID-NAD 83 1z" PIPE FOUND N=685,423.70' E=1,560,520.29' CITY OF SALISBURY D.B. 786, PG. 823 ROWAN CO. PARCEL ID: 402 068 USE: MUNICIPAL 1 L J_ X X X GATE OUTLET PROTECTION TABLE OUTLET PIPE LA (FT) W1(FT) W2 (FT) DA (IN) NCDOT CLASS PIPE - 1 5 4.0 7.5 1.5 A PIPE-4 5 4.0 7.5 1.5 A I 1 BEFORE YOU DIG! CALL 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAW! COORDINATE WITH NCDOT AND/OR LOCAL TRANSPORTATION AUTHORITY AND FOLLOW TRAFFIC MANAGEMENT PLAN FOR ALL WORK WITHIN AND ADJACENT TO PUBLIC RIGHT OF WAY. LU w B EC LU LU a_ 0 ENGINEERING I PLANNING I ENVIRONMENTAL 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LLJ \���1lillrrrr�2 L.j U i CAR LU LU A _ m _ 5 37-s- C0 ccNGINE��-�G�: ::D cN� .�`� ''�rrtl�l��\\`\� U} 09/17/2019 Z Q LU �� RqT •. U � NCBELS#C-3448 U) �%i �'• '• Q' : 0 ,'�• TH CAPP 0 O 0 PHASE 2 ESC PLAN PREPARED FOR: TERAMORE DEVELOPMENT, LLC PO BOX 6460 THOMASVILLE, GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 20' (H) (V) 20 10 0 20 40 SHEET: C301 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE GENERAL NOTES EROSION CONTROL CONSTRUCTION SEQUENCE 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 1. OBTAIN NECESSARY PERMITS FROM ALL REGULATORY AUTHORITIES. CONTRACTOR RESPONSIBLE FOR ALL 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. DEMO PERMITS AS WELL AS WASTE OR BORROW SITE SELECTION AND PERMITTING. 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 2. CONTRACTOR SHALL LOCATE ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION. SOFT DIG ALL 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS UTILITIES WITHIN GRADING AREA TO IDENTIFY POTENTIAL CONFLICTS. ASSOCIATED WITH RELOCATION. 3. STAKE -OUT ALL EROSION CONTROL MEASURES PRIOR TO CONSTRUCTION. 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND 4. MAINTAIN NPDES TEMPORARY SEEDING SCHEDULE (SHEET C001) FOR ALL EXPOSED SOILS FOR THE DURATION WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH OF CONSTRUCTION. RELOCATION SHALL BE INCLUDED IN THE BASE BID. 5. INSTALL PIPE - 1 WITH INLET & OUTLET PROTECTION. 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR 6. INSTALL TEMPORARY GRAVEL CONSTRUCTION ENTRANCE TO PROVIDE ACCESS FROM HEILIG ROAD. COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. 7. INSTALL SILT FENCE AND STONE OUTLET(S) AT INDICATED AREAS. 8. INSTALL SKIMMER BASIN AND PERMANENT OUTLET CONTROL STRUCTURE WITH OUTLET PIPE. ATTACH MAINTENANCE PLAN FAIRCLOTH SKIMMER TO OUTLET CONTROL STRUCTURE WHILE BASIN IS USED AS SKIMMER. SKIMMER BASIN 1. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY EXISTING BUILDING DEMOLITION. TO REMAIN IN PLACE UNTIL ALL AREAS HAVE BEEN ADEQUATELY STABILIZED AND APPROVAL TO REMOVE 2. CONTRACTOR IS RESPONSIBLE FOR ALL EROSION AND SEDIMENTATION CONTROL REQUIREMENTS AND SHALL MEASURE HAS BEEN RECEIVED BY ROWAN COUNTY EROSION CONTROL. COMPLY WITH THE LATEST EDITION OF THE NORTH CAROLINA EROSION AND SEDIMENTATION CONTROL 9. INSTALL TEMPORARY DIVERSIONS TO CONVEY RUNOFF TO SKIMMER BASIN. MODIFY TEMPORARY DIVERSIONS MANUAL. AS NEEDED DURING GRADING OPERATIONS TO ENSURE CONSTRUCTION RUNOFF IS DIRECTED TO SKIMMER 3. PER NPDES REQUIREMENTS, CHECK ALL EROSION AND SEDIMENTATION CONTROL DEVICES AND STORMWATER BASIN WITH POSITIVE DRAINAGE. RUNOFF DISCHARGES FROM EACH OUTFALL SHOULD BE INSPECTED EVERY SEVEN DAYS AND WITHIN 24 HOURS 10. REMOVE EXISTING VEGETATION WITHIN GRADING LIMITS AND DISPOSE AT AN APPROVED SITE. AFTER ANY STORM EVENT. A RAINFALL GAUGE SHALL BE KEPT ON SITE, AND A RECORD OF RAINFALL AMOUNTS 11. INSTALL PIPE NETWORK WITH INLET AND OUTLET PROTECTION. PIPE NETWORK MUST DISCHARGE TO SKIMMER AND DATES MUST BE RECORDED AND KEPT ON SITE. RECORDS OF INSPECTIONS OF DEVICES AND OUTFALLS BASIN DURING CONSTRUCTION ACTIVITIES. SHOULD BE KEPT AND VISIBLE SEDIMENTATION OUTSIDE THE DISTURBED LIMITS SHOULD BE NOTED. ANY 12. INSTALL ALL UNDERGROUND UTILITIES. ANY RUNOFF COLLECTED IN UTILITY TRENCHES MUST BE DEWATERED ACTIONS TO CONTROL FUTURE RELEASES AND CLEANUP OF SEDIMENT MUST BE RECORDED. A SAMPLE LOG TO THE SKIMMER BASIN. FOR RECORD KEEPING IS AVAILABLE FROM NCDEQ DIVISION OF WATER QUALITY, STORMWATER AND GENERAL 13. AFTER GRADING REACHES SUBGRADE ELEVATIONS, INSTALL STONE BASE IN PARKING AND BUILDING PAD PERMITS UNIT. AREAS TO PROTECT EXPOSED SOILS. 4. CHECK ALL EROSION CONTROL DEVICES WEEKLY AND AFTER EACH RUNOFF PRODUCING STORM EVENT AND 14. COORDINATE WITH NCDOT TO IMPLEMENT TRAFFIC CONTROL PLAN FOR CONSTRUCTION OF RIGHT TURN MAKE ANY NECESSARY REPAIRS AS NEEDED TO ENSURE DEVICES ARE FUNCTIONING AS INTENDED. TAPER. 5. REMOVE SEDIMENT DEPOSITS FROM SILT FENCE AND STONE OUTLETS WHEN DEPOSITS REACH HALF 15. STABILIZE ALL EXPOSED SOILS WITH SEEDING OR PERMANENT LANDSCAPING. CAPACITY, REPAIR ANY BREAKS IMMEDIATELY. 16. AFTER SITE STABILIZATION AND APPROVAL BY ROWAN COUNTY EROSION CONTROL, REMOVE SKIMMER BASIN 6. REPLACE GRAVEL CONSTRUCTION ENTRANCE AS NECESSARY. TO COMPLETE CONVERSION TO PERMANENT SAND FILTER FOR POST CONSTRUCTION STORMWATER CONTROL 7. CONTRACTOR WILL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALL FINES LEVIED DUE TO NOT MAINTAINING AND COMPLETE FINE GRADING. DO NOT ALLOW DISCHARGE INTO SAND FILTER UNTIL SITE IS COMPLETELY PROPER EROSION CONTROL MEASURES AT ALL TIMES /C STABILIZATION TIMEFRAMES SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES, SLOPES 7 DAYS NONE 0� HIGH QUAILTY WATER (HQW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS AREA ALLOWED. SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES GREATER THAN 50' LENGTH ALL OTHER AREAS WITH SLOPES NONE, EXCEPT FOR PERIMETERS FLATTER THAN 4:1 14 DAYS AND HQW ZONES SEE SHEET C001 FOR COMPLETE NDPES PERMIT INFORMATION STABILIZED. - - - - - - - - - - - - - - - - - - - �J/ N , "-,, 17. INSTALL REMAINING PERMANENT LANDSCAPING. ROAD R/W 18. REMOVE REMAINING EROSION CONTROL MEASURES AFTER RELEASE BY PERMITTING AUTHORITIES. - - - - ST ST EEEt�, - - - - - - - - - - - - - - - - - - / EUGE OF PAVEMENT _ _ _ - _ _ _ - _ - - _ _ - - _ _ - - - EDGE OF PAVEMENT - - - / HE;LIG ROAD ($.R. 2528) - I PUBLIC RM / N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG.# '\ / / / I I \ \ C �c5 N.C. GRID- D 83 \ NA DITCH TO BE LINED ,, ' PIPE FOUND, WITH CURLEX II N=685,791.51' \ o N N.C. RID-NAD $� DITCH TO BE LINED \ '-" PIPE FOUND \ WITH CURLER II N=685,581.32' / E=1,560,485 45 - - / 1 I \ I - / DROP INLET i ' _ - - _ - L ( RIM=812.02' _ LIMITS OF 817INV. IN=809.66' I / i T INV OU809�&3 / / - / - \ I I - DISTURBANCE � / _ _ # _ _ _ S48 _ 2.33± ACRES / - 820 ST ST ST ST ST ST ST ST ST ST ST ST ST INV. = 816.75 BAR UND I I I 000 18'/RCP Ni REBAR/ SET OBIIkRVED RIGHT-OF-WAY R/p R/Vll_ / R/W RAN v ' RAN T RAN RAN � E-1,560,7 EDGE OF PAVEMENT 4 - - 7" - 316 01_ - - PIPE-1 - - = _ _ � - - _ S48° 25' 26"E747- 0,, mmC.'.m'., z I INV. = 817.50 / I / I / RM RM RM RM RM / :77 a I / GATE I / D P INLET -1 R M :822.10 o� h� JAKEALEXANDER BLVD, S J � 1%b / P �•`��� O°moo yF'�/�R SITE �o S�cTTFRs O Fliy VICINITY MAP (NTS) LEGEND 100 P GAS W FO PROPERTY LINE EXISTING CONTOURS PROPOSED CONTOURS BUILDING SETBACK LANDSCAPE BUFFER EX. OVERHEAD ELECTRIC EX. NATURAL GAS EX. WATER EX. FIBER OPTICS SILT FENCE TEMPORARY DIVERSION LIMITS OF DISTURBANCE RIPRAP INLET PROTECTION OUTLET PROTECTION HARDWARE CLOTH INLET PROTECTION 1 " DPE INV OUT: 819.50 / I I/ / STRUCTURE TABLE `A's l STRUCTURE NAME DETAILS L- I o I / RIM = 821.60' 0 o I / I SEPTIC FIELD TO REMAIN I / CURB INLET - 1 INV IN = 818.55' / 3 / 518" REBAR I / / �, / ) ��-i UNDISTURBED (TEMPORARY INV OUT = 818.45' Lua / FOUND I / / / / \I / / EXCLUSION FENCE SEE DET. 5/C904) - I // 4"1 � / 823 / I RIM = 822.10' Q co r / INLET PROTECTION I \ / DROP INLET - 1 INV OUT = 819.50' o SILT FENCE W / / I TYP. AT ALL INLETS) NAIL o / SEE DET. 2/C902 a / / I 823 - ( - 82075' 2 OUTLET STRUCTURE - RIM = . I SEE DET. 4/C90 FOUND / / � / � � , 19 19/\ / INV OUT = 815.00 / / INV. = 818.00 / / \ 1 1 S/ I / / / / / - / - PIPE TABLE 1 do /- / / / �� PIPE NAME SIZE LENGTH SLOPE PIPE - 1 15 INCH CORRUGATED HDPE PIPE 74.16' 1.01% DITCz �` D y D . ` WITHHTO CURBEX E. IINED - - - - - - \ \ D.J785,APG. 108Y o o /� - - - °. D D ' ' p/ ° 7 D I ROVyAN CO. PARCEL PIPE - 2 15 IN CORRUGATED HDPE PIPE 185.91 0.50 /o / O D 4 \Ds D - o HARDWOOD - - //ID: 402 067 ` \ SE MUNICIPAL PIPE - 3 15 INCH CORRUGATED HDPE PIPE 77.49' 0.57% INV. = 814.50 15 INCH CORRUGATED HDPE PIPE 73.92' 0.65% 1 _j I I^ DI O lyr / l 1-1 \ / 00 - POINT OF BEGINNING I / / _ / �N.C.GRID-NAD-83 g' REBAR SET 1 / N=685,749.00' / v/ ; / / 8' ST\E=1,560,309.16' DOLLAR GENERAL' / 80' 9,100 SQ.FT. F.F.E. = 824.50 I � I I I I � I � I I � 1 I I � I .� STONE OUTLET Z SEE DET. 6/C902 j I/ 1 �i \-r\llvl 04 I .OV 15"I OE INV IN: 818.55 15. HDPE INV OUT: 818.45 8 6" ROOF DRAINS 1 I // / // / �• / WITH SPLASHBLOCK / / / / / a / A. SEE DET. 8/C902 ...D ° /'� I I SILT FENCE \/ e g .: w I // / / / �, SAND FILTER J SEE DET. 3/C904 / / ND OUTLET STRUCTURE::: / / / 830 SEE DET. 2/C904 / / /;:.::, .:: / DITCH TO BE LINED - I/ WITH CURLEX II / 00 � O F0)a NAIL / $4//° 50' 56 FOUND _ - / _ _ _ -wrn / � X X 8' CHAIN LINK E c�F � X � � � � 1 X � 8' CHAIN LINK FENCE z 1 " PIPI /I/ ROWAN COUNTY FOUN / I BOARD OF EDUCATION I /� D.B. 623, PG. 343 1"' RCP II / x ROWAN CO. PARCEL ID: 402 036 INV=815.39' / / I II / 1 / �� USE: MUNICIPAL 1 15" RCP NV=815.85' \ I \ SEE DET. 2/C902 N N.C. GRID-NAD 83 1z" PIPE FOUND N=685,423.70' E=1,560,520.29' CITY OF SALISBURY D.B. 786, PG. 823 ROWAN CO. PARCEL ID: 402 068 USE: MUNICIPAL 1 OUTLET PROTECTION TABLE OUTLET PIPE LA (FT) W1(FT) W2 (FT) DA (IN) NCDOT CLASS PIPE - 1 5 4.0 7.5 1.5 A PIPE - 4 5 4.0 7.5 1.5 A I 1 BEFORE YOU DIG! CALL 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAW! COORDINATE WITH NCDOT AND/OR LOCAL TRANSPORTATION AUTHORITY AND FOLLOW TRAFFIC MANAGEMENT PLAN FOR ALL WORK WITHIN AND ADJACENT TO PUBLIC RIGHT OF WAY. Lu w B EC Lu Lu a_ 0 ENGINEERING I PLANNING I ENVIRONMENTAL Q 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz W > \���11111rrrr2� LLI U i .� \H CARD // Lu Lu A _ m - 5 -_ U0 ccNGINE��-�G�: ::D cN� .�`� /'�rrrl�lll\\`\\ U} 09/17/2019 Z Q Lu • �• PO •� p� RqT •. Q U NCBELS#C-3448 . U) �%i �'• '� Q' : 0 ,'�• CAPP •,` O 0 FINAL PHASE ESC PLAN PREPARED FOR: TERAMORE DEVELOPMENT, LLC PO BOX 6460 THOMASVILLE, GA 31758 DATE: REVISIONS: SHEET SIZE: 24" x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 20' (H) (V) 20 10 0 20 40 SHEET: C302 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE r GENERAL NOTES ON -SITE UTILITY NOTES 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 1. FOR GENERAL SITE WORK, SEE SHEET C100. 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. 2. ALL WATER DISTRIBUTION PIPE SHALL BE DUCTILE IRON WATER PIPE CONFORMING TO ALL STATE AND LOCAL 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. STANDARDS. 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS 3. ALL DUCTILE IRON PIPE SHALL BE PRESSURE CLASS 50 OR GREATER. ASSOCIATED WITH RELOCATION. 4. ALL SANITARY SEWER PIPE SHALL BE SDR 35 PVC PIPE FOR GRAVITY FLOW AND SCH 40 FOR PRESSURED FLOW 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND (BEDDED IN STONE) CONFORMING TO ALL STATE AND LOCAL STANDARDS. WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH 5. FITTINGS 4" AND LARGER SHALL BE DUCTILE IRON (PUSH -ON TYPE JOINT) CONFORMING TO ANSI AND AWWA RELOCATION SHALL BE INCLUDED IN THE BASE BID. STANDARD SPECIFICATIONS. 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR 6. PIPE AND FITTINGS 3" AND SMALLER ARE TO BE EITHER PVC SCHEDULE 40 WITH SOLVENT WELD JOINTS OR SOFT COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. K-COPPER. GATE VALVES SHALL BE TELESCOPE TYPES. ALL VALVES MUST BE MUELLER, M&H OR KENNEDY AND BE RATED 175 PSI WORKING PRESSURE AND 300 PSI HYDROSTATIC TEST PRESSURE. ALL VALVES WILL BE OPEN LEFT AND BE CAST OR DUCTILE IRON BODIED. 7. ALL WATER MAINS SHALL HAVE A MINIMUM COVER OF 3' ABOVE THE TOP OF THE PIPE. 8. THE MINIMUM HORIZONTAL SEPARATION BETWEEN THE CLOSEST TWO POINTS OF THE WATER AND SEWER LINE IS TEN FEET (10'). THE MINIMUM VERTICAL SEPARATION BETWEEN THE CLOSEST TWO POINTS OF THE WATER AND SEWER LINE IS EIGHTEEN INCHES (18"). 9. THRUST BLOCKS SHALL BE PROVIDED AT ALL BENDS. 10. DIMENSIONS SHOWN ARE CENTERLINE OF PIPE OR FITTINGS. 11. ALL SPRINKLER, DOMESTIC, AND SANITARY LEADS TO THE BUILDING SHALL END 5' FROM THE EDGE OF BUILDING AS SHOWN ON PLAN AND SHALL BE PROVIDED WITH A TEMPORARY PLUG AT END (FOR OTHERS TO REMOVE AND EXTEND AS NECESSARY). 12. ALL WATER MAINS SHALL BE HYDROSTATICALLY TESTED AND DISINFECTED BEFORE ACCEPTANCE. SEE SITE WORK SPECIFICATIONS. 13. ALL GATE VALVES/BOXES SHALL BE TO TOWN/CITY STANDARDS. 14. ALL TRENCHING, PIPE LAYING, AND BACKFILLING SHALL BE IN ACCORDANCE WITH FEDERAL OSHA REGULATIONS. 15. SEE SITE SPECIFICATIONS FOR BACKFILLING AND COMPACTION REQUIREMENTS. 16. SITE CONTRACTOR SHALL HAVE APPROVAL OF ALL GOVERNING AGENCIES HAVING JURISDICTION OVER THIS UTILITY GAS \ - SYSTEM PRIOR TO COMPLETION. POLE VLV I I 17. INSTALLATION OF THIS PLAN SHALL BE DONE IN STRICT ACCORDANCE WITH SITE WORK SPECIFICATIONS. GASH GAS -I P P 18. SEE ELECTRICAL PLAN FOR SITE LIGHTING LAYOUT. GAS GAG )_°AG�GA��G _ I N 19. SEE'M' SHEETS FOR CONTINUATION OF FACILITIES INTO AND OUT OF THE BUILDING. GAS-GS- �1 I I -GpG-GAS-GAG-GAs AG_G 20. CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH LOCAL POWER PROVIDER FOR THE LOCATION OF THE I I I I°AS GAG_ GAS TRANSFORMER AND ANY NECESSARY CONDUITS. GAS VLV. 21. CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH LOCAL TELECOMMUNICATION PROVIDER THE LOCATION - OF ANY PEDESTALS AND NECESSARY CONDUITS. / SI Wr GHT / I IN�ERSECfI� / I N.C. GRID-NAD 83 I 7 ' PIPE FOUND, / N=685,791.51' I I EDGE P•FAVZUfNT \ /� LOCAL UTILITY COMPANIES UTILITY COMPANY NAME PHONE WATER SALISBURY ROWAN UTILITIES (704) 638-5300 POWER DUKE ENERGY (800) 452-2777 NATURAL GAS PIEDMONT NATURAL GAS COMPANY (800) 752-7504 TELEPHONE AT&T (800) 225-5288 SANITARY SEWER ROWAN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT (704) 216-8533 2" PRESSURIZI DISCHARGE CONSU MANUFACTURER F( INSTALLATION LOCATI( VC INVERT FROM BUILDING RGENCY FLOAT SWITCH -LOAT SWITCH (LAG) -LOAT SWITCH (LEAD) FLOAT SWITCH I -FLOATATION - 0 PSI ICRETE --- __---- -___---____ GRINDER PUMP TANK - _ SCALE: 1" = 2' ST � ST �j � �� -A GAS�GAS--GAS - � GASH GASH GASH G-GAS ='- aA3= GAG- GASH GAG- GAS- GAS- GAS - - - - - - - EDGE OF PAVEMENT - - - - - - HEiLIG ROAD (S.R. 2528) - 60' PUBLIC RM N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG. 5�� / � N.C. RID-NAD $� \ � \\ \I z' PIPE FOUND N=685,581.32' I \ - i E=1,560,721.22' - - - - - - -- -__-_ _ 1" WATER METER J ° COORDINATE TAP 5 w_=w ° �'° WITH SALISBURY I ifT ROWANUTILITIES_-Fp � FO - FG �� FG - FO - FO � FG = FO - FO � FOL_F° - FG F° FGTILI➢� �' w °�' /T ST ST ST ST ST ST ST ST / P P{5CE%FO- o � 4-' UTILITY / 3n ° POLE / / 4 RPZ WITH HEATED / ENCLOSURE ° w OBSERVED RIG14f-OF-WAYpR/W i R/W R/Vll_ RAN RAN RAN RM RAN 1" RPZ WITH HEATED <° I 3 IRRIGATION TO BE I / / / °� ENCLOSURE DESIGNED BY OTHERS o F / 80 / REBAR/ I I LIGHTED PYLON SIGN Z==zzz - GA - MTR. GAS r VLV.L \ / \ LL. / 1 a 4/ / �N // I w:iz_ o I ° / .\ _ / 3 / 5/8" REBAR iU W a / J FOUND ,/ '° / / / Luca v- m I (DI W 3 1\ UTILI ' POLq 1 / 0 1 /o I , / POINT OF BEGINNING// N.C. GRID-NAD-83 5i REBAR SET S / / N=685,749.00' / E=1,560,309.16' v / 8014 �- I / 3 / I\ &'S� W LLJ co o / 031 ° /// N //// zl Ii y� It 10' SETBACK °3/4" PIP I �cLO b o_"3 / III 'FOUND 1 NAIL / / / - 84//° 50' 56"E FOUND �- x - x �� N4856' 52"W - 320.81' 8' CHAIN LINK FENCE x x zx - z �-k x ° x \I / � UTII,ITI 9 71� _ -� 8' CHAIN LINK FENCE �I�I y x MULTIPLE ° TELEPHONE PEDESTALS (i AND COMMUNICATION ° x x VAULTS ON CONCRETE /FG �\ FG ROWAN COUNTY BOARD OF EDUCATION D.B. 623, PG. 343 ROWAN CO. PARCEL ID: 402 036 USE: MUNICIPAL FG - FG - S48° 25' 26"E I t- / GATE r- PRIMARY FIELD Ir- / I/ \ REPAIR FIELD - \ 3 / I / SEPTIC FIELD TO REMAIN UNDISTURBED (TEMPORARY / EXCLUSION FENCE SEE DET. 5/C904) / 1,500 GAL. SEPTIC TANK ' I co \I / TAIL LINES AREA LAID OUT FOR I / / INFORMATION PURPOSES ONLY. ASSUMING AN LTAR OF 0.35 AND A FLOW OF 200 GPD 3 / BASED ON THE DOLLAR GENERAL MOU. SEE SEPTIC PERMIT FOR ACTUAL LAYOUT. O I \ OITY CIF SALISBURY ' D. Bt. 785, PG. 108 - GG ROVyAN CO. PARCEL // ID- 402 067 MUNICIPAL - - 1 / 00 - \\\� B,IEB R -_--_ \ SET\ ' \ 3 / 19" 00 . CD _ \ I _ N 1/ N.C. GRID-NAD 83 J \ ' 11" PIPE FOUND N=685,423.70' \CITY OF SALISBURY E=1,560,520.29' ' D.B. 786, PG. 823 ' ROWAN CO. PARCEL ID: 402 068 ' USE: MUNICIPAL \ , LEGEND - - PROPERTY LINE 100EXISTING CONTOURS 10o PROPOSED CONTOURS BUILDING SETBACK -GAS - - - - - - - - - LANDSCAPE BUFFER - BEFORE YOU DIG! CALL 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAW! COORDINATE WITH NCDOT AND/OR LOCAL TRANSPORTATION AUTHORITY AND FOLLOW TRAFFIC MANAGEMENT PLAN FOR ALL WORK WITHIN AND ADJACENT TO PUBLIC RIGHT OF WAY. 0 GAS W FO EX. OVERHEAD ELECTRIC EX. NATURAL GAS EX. WATER EX. FIBER OPTICS Lu w B EC Lu Lu J a_ 0 ENGINEERING I PLANNING I ENVIRONMENTAL Q w 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LU \����liiirrrr�� LLl• U �H CAR '% Lu oFEsS Lu A _ m 5 -_ ` C/) �/v .•ccNGINE��-�G�: � C\A U} 09/17/2019 Z J U : NCBELS#C-3448 * U) �%i •'• '• Q' : 0 ,'�• CARo •,` ���������HN�♦ O 0 UTILITY PLAN PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: r 20 10 0 20 40 SHEET SIZE: 24" x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 20' (H) (V) SHEET: C400 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. GENERALNOTES 1. CONTRACTOR IS TO VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 2. ALL WORK IS TO BE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. 3. ALL PERMITS ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. EXISTING UTILITIES ON SITE SHALL BE RELOCATED AS REQUIRED. CONTRACTOR SHALL PAY ALL COSTS ASSOCIATED WITH RELOCATION. 5. CONTRACTORS ARE TO FULLY ACQUAINT THEMSELVES WITH ALL UTILITIES WITHIN THE CITY AND STATE ROW AND WITHIN THE PROPERTY BOUNDARIES WHICH WILL REQUIRE RELOCATION. ALL COSTS ASSOCIATED WITH RELOCATION SHALL BE INCLUDED IN THE BASE BID. 6. ALL WORK PERFORMED WITHIN NCDOT ROW SHALL BE PER NCDOT SPECS AND SHALL BE INSPECTED FOR COMPLIANCE BY STATE INSPECTORS AT THEIR DISCRETION. 0"7 p p - I - . - � - � - ROAD RAN - EDGE OF PAVEMENT HEILIG ROAD (S.R. 2528) - 60' PUBLIC RM N.C.D.O.T. PROJECT # 6.637024 - D.B. 880, PG. 509 \ - N.C. GRID-NAD 83 \ 7' PIPE FOUND \ I N=685,791.51' - E=1560,485.25' EDGE OF PAVEMENT \ STREET PLANTINGS 10' X 70' SIGHT \ RM -11 SEED TRIANGLE I GA - 25 \I, UTILIT �48° 18' 27" - 316.01' PO \ y y y y .v y y y .l' y y .v y _ `1' •� ROAD RIve w y , WTILITY - o - - P - - \ POLE , 1 y y y y y y y y y y y y y y y y y y y y y y y -' - ` P P Al UTILITY PQkE y y y v y y y l y y y y y y l y y y y y y l l y y y R�P�� y y y y y y y y y y y y y y y y y y y y y y y y y y y y y OBSERVED RIGHT -OF -WAIT y y y w y w w w y �m R/Wv Ri11V �' R/W y F�W y y y W y R/W R/W y R/yW y / �/ �Y �Y Y �Y �Y �Y �Y y •�, y �Y �Y �Y �Y �Y �Y Y g` I �Y �Y/ �Y �Y �Y Y �Y �Y ✓ �Y Y �Y �L �Y �Y �Y Y �Y �Y �Y �Y �Y �Y �Y ` I ' REBAR � �1/ W SET o w y 50' SETBACK y y y L- / 5/8" REBAR FOUND / / y y y w y w \j/ �Y �Y a I wW y y y y y / \/ � \/ ' o y �Y y y y y JOD y y / � �/ y y y y y \ / oLl� 10 - u y y y UTILITY 71 POLE OR IV IV /� I11dill y y y y •��`�I�� S ` I' n y y y W W W y y y y W W y y y y y y y y W W fj y y y y y y y W ROAD R/W EDGE OF PAVEMENT N.C. RID- AD 83 z" PIPE FOUND N=685,581.32' E=1,560,721.22' EDGE OF PAVEMENT i LEGEND - - PROPERTY LINE 100 EXISTING CONTOURS 10o PROPOSED CONTOURS - - BUILDING SETBACK - - - - - - - - - LANDSCAPE BUFFER P EX. OVERHEAD ELECTRIC GAS EX. NATURAL GAS W EX. WATER FO EX. FIBER OPTICS 10' X 70' SIGHT 'I` DOLLAR GENERAL LANDSCAPE NOTES: TRIANGLE SEED A. GRADING NOTES S48° 25' 26"E - 2. TOP SOIL SHALL BE STRIPPED FROM ALL CUT AND FILL AREAS, STOCKPILED AND REDISTRIBUTED \l/ OVER GRADED AREAS. PROVIDE EROSION AND SEDIMENTATION CONTROLS AROUND STOCKPILES �L SEED DURING CONSTRUCTION. 3. TILL SOIL TO A DEPTH OF 4" MINIMUM. 4. REMOVE ALL ROCKS LARGER THAN 1" MEASURED IN LARGEST DIRECTION. R/W R'�;'. ; R/W w 5. 6. GRADE ALL AREAS TO MAINTAIN POSITIVE SLOPE AWAY FROM BUILDING. ALL GRADED AREAS TO RECEIVED SEED OR SOD, TOP SOIL, STRAW AND WATER UNTIL A HEALTHY STAND OF GRASS IS OBTAINED. 7. REFER TO GRADING SHEET FOR MAXIMUM SLOPES. GATE I B. LAWN SEEDING & SODDING NOTES: 1. ALL LAWNS FROM FACE OF THE BUILDING AND ON THE SIDE WHERE THERE IS PARKING OR A STREET ARE REQUIRED TO BE FULLY SODDED. ALL OTHER LANDSCAPE ARES TO RECEIVE SEED. SEED I 2. AREAS TO RECEIVE SEED OR SOD SHALL BE CLEAN OF DEBRIS AND FREE OF WEEDS. 1 1 3. SEED MIX TO BE DROUGHT TOLERANCE FESCUE OR REGIONAL SPECIFIC BLEND. TO OF THE SEED I MIXTURE TO BE ANNUAL RYE TO AIDE IN LIMITING EROSION OF PERENNIAL SEEDING DURING GERMINATION. \1/ \ 4. STRAW SHALL BE THRESHED STRAW OF HAY, OATS, WHEAT, BARLEY OR RYE. SPREAD AT A RATE OF \, � I J 2-1/2 TONS PER ACRE. STRAW, NETTING AND OTHER ANTI -EROSION MATERIALS TO BE REMOVED o AFTER ESTABLISHED LAWN. SEPTI�RE D TO MAIN 5. MAINTENANCE SHALL BE BEGIN IMMEDIATELY AFTER SEEDING. WATER REGULARLY TO KEEP LAWN MOIST TOEPT GERMINATION ANDED LAWNIPRIORI GRWTH ANDSESSIOIN TIO TIHE EXCLl7SION FENCE SEE DETA51C904) R ORIMINTAN B EI STAND OF ES ABLIISHMAXIMZE ACHIEVE AN ACCAREAS SOTORE POSDATE, FREE OR ERODED OR BARE AREAS. co \ ' \4/ C. LANDSCAPE NOTES J 1. ALL SOILS USED FOR PLANTING SHALL CONSIST OF REGIONALLY APPROPRIATE SOILS. `V `� \V \V Y 2. ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 3" DEPTH OF MULCH, WITH EDGING AS REQUIRED. 3. ALL TREES LOCATED IN SOD AREAS SHALL HAVE A MULCH RING WITH EDGING AS REQUIRED. \V \V \V \V \V 4. ALL PLANTINGS SHALL BE THOROUGHLY WATERED BY THE LANDSCAPE CONTRACTOR AT THE TIME OF THE PLANTINGS. \V \V \V \ '\V 5. PRIOR TO FINAL ACCEPTANCE OF STORE BY DOLLAR GENERAL. THE SITE SHALL BE CLEAN OF ALL CITY OFSALISBURY D.B. 785, PG. 108 DEBRIS AND TRASH, AND MEET ALL REQUIREMENTS OUTLINED IN SECTIONS A-C ABOVE. \l/ \l/ \l/ �' ROWAN CO. PARCEL 6. MAXIMUM SLOPE CUTS SHALL NOT EXCEED 4:1. ALL DISTURBED GRADES GREATER THAN 8:1 SHALL ID: 402067 BE STABILIZED BY SODDING. SODDING PINS ARE TO BE USED ON ALL 4:1 GRADES. \V ' \V USE: MUNICIPAL 7. VEGETATION AT ENTRY SHOULD BE LOW TO ENSURE VISIBILITY OF STORE. 8. IF TREES ARE REQUIRED IN FRONT OF BUILDING, SELECT SMALL LEAFED, NON DENSE SPECIES THAT \V \ WILL NOT INTERFERE WITH THE VISIBILITY OF STORE. THE SPACING SHALL CREATE VISUAL CORRIDORS TO STORE AND PYLON OR MONUMENT SIGN. x 00 \V \4,, '� _ Lu D. IRRIGATION NOTES 1. ALL LANDSCAPE AREAS AND LAWNS ADJACENT TO PAVED AREAS AND/OR STREET ARE TO BE FULLY ' IRRIGATED. REBAR 2. IRRIGATION SYSTEM TO INCLUDE ALL SPRAY HEADS, VALVES AND CONTROLLERS. A SEPARATE SET METER AND BACKFLOW PREVENTER WILL BE REQUIRED. \V ' 3. A SEPARATE METER AND BACKFLOW PREVENTER WILL BE REQUIRED. 4. LOCATE HEADS A MINIMUM OF 2'-0" FROM EDGE OF PAVEMENT/CURB. SEED V \4/ 5. LOCATE RAINBIRD CONTROL PANEL IN RECEIVING AREA NEXT TO ELECTRICAL PANELS. W W W I O IV W W W �Y �Y �Y y �Y �Y �Y �Y �Y y �Y �Y �Y �Y `I' `I' `I, `I, `I, 00 I I 10SETBACK \l/ \l/ \l/ `/ ' 00 j NAIL 7° 50' 56"E FOUND x x x - x - x - X N48° 56' 52"W - 320.81' - X X.* X W - X - - X X X X XS' CHAIN LINK FENCE x �� ' 9 71' x x x T CHAIN LINK FENCE ' 'PIPE z FOUND � x ROWAN COUNTY W I BOARD OF EDUCATION N.C. GRID-NAD 83 D.B. 623, PG. 343 ' 11" PIPE FOUND x ROWAN CO. PARCEL ID: 402 036 N=685,423.70' i I USE: MUNICIPAL E=1,560,520.29' x CITY OF SALISBURY ' D.B. 786, PG. 823 X x ' ROWAN CO. PARCEL ID: 402 068 ' USE: MUNICIPAL W I N I � W W co x X x - GATE 20 10 0 Lu w B EC Lu Lu J a_ O ENGINEERING I PLANNING I ENVIRONMENTAL Q c ) 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LLJ \\ok11II1j/j � uj U CAR % Lu Lu ` U) ccNGINE��-�G�: � C\A .�`� c0 09/17/2019 Z Q •`•• �REC,•P'� �'• • �• PO •• RqT •. J Q U : NCBELM-34481 Cl) �%i •'• '• Q' : O •� •.....•ON; O z ,•• ,'�• CAR •,` O 0 LANDSCAPE PLAN PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: 20 40 r=77- 2::] DATE: 08/01/2019 PROJECT NUMBER. 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: 1" = 20' (H) (V) SHEET: G100 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. 1 C900 4 C900 7 C900 HEAVY-DUTY ASPHALT PAVING GENERAL NOTES: 1. VERIFY EXACT PAVING DESIGN WITH GEOTECHNICAL ENGINEER FOR PROJECT VAN ACCESSIBLE PARKING SIGN WALL MOUNTED THIS SIGN TYPICAL AT ALL "VAN ACCESSIBLE" PARKING SPACES STANDARD ALUM. HANDICAPPED PARK SIGN R7-8 FASTENED TO BUILD) STANDARD ALUM. MAXIMUM PENAL' SIGN R7-8D FASTENED TO BUILDIN z ti SIDEWALK CURB AND GUTTER VAN ACCESSIBLE RESERVED PARKING MAXIMUM PENALTY $250 ONE SIGN PER HANDICAP PARKING SPACE/ WHERE 2 SPACES FACE EACH OTHER, ONE POST SHALL BE USED WITH SIGNAGE ON EACH SIDE. 6" 18" ASPHALT PAVING SEE DETAIL 6 a <• .a 1 RAD. 6" - O O ASPHALT SHALL BE" -� ABOVE GUTTER EDGE I I I I I � II � II I II II 3000 PSI CONC. COMPACTED ABC CURB AND GUTTER z C900 5 C900 ACCESSIBLE PARKING SIGN, AS REQUIRED COLORED TOOLED/SERRATED SLIP RESISTANT SURFACING AND/OR TACTILE WARNING DEVICE AS REQUIRED BY AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES AND CODE REQUIREMENTS 8 C900 ACCESSIBLE PARKING SIGN, AS REQUIRED STANDARD ASPHALT PAVING bl1�R•l WIN i01 1rlw� rV r GENERAL NOTES: 1. VERIFY EXACT PAVING DESIGN WITH GEOTECHNICAL ENGINEER FOR PROJECT HANDICAP RAMP -TO 10 4" PARKING SPACE STRIPE. PAINT COLOR TO BOLLARD PAINTED YELLOW BE PER THE AUTHORITY AT PARKING SPACE IN HAVING JURISDICTION. FRONT OF BUILDING STANDARD ACCESSIBLE PARKING SYMBOL PAINTED Z ON PAVEMENT. PAINT COLOR W QJ TO BE PER THE AUTHORITY HAVING JURISDICTION. Lu > Lu C 4" STRIPES @ 24" O.C. AT 45 - DEGREES. PAINT COLOR TO BE PER THE AUTHORITY HAVING :I LLl Z JURISDICTION. �0� N I - o J Qco SEE PLAN t� 0 0 D MAX 2% SLOPE 2o�cj6 (11J 0 � U) 0 NOTE: ALL ACCESSIBLE RAMPS AND ACCESS AISLES SHALL MEET ALL SEE SITE PLAN FOR CODES AND ADAAG REGULATIONS. SIDEWALK WIDTH — DUMPSTER PAD SECTION 4000 PSI CONCRETE WITH W2.9 X W2.9 W. W. F. OR # 3'S AT 18" ASPHALT PAVING SEE DETAIL co _x __F _x_ -- X , rFj • �• )III I I I I —I —8 I _ I 1-1 COMPACTED SUB -GRADE STRIPING TOP COAT SHERWIN WILLIAMS - PROMAR TRAFFIC MARKING PAINT 'H.C." BLUE 3 C900 6 C900 9 C900 HANDICAPPED PARKING SIGN WALL MOUNTED STANDARD ALUM. HANDICAPPED PARKING SIGN R7-8 FASTENED TO BUILDING STANDARD ALUM. MAXIMUM PENALTY SIGN R7-8D FASTENED TO BUILDING z F.- SIDEWALK SIDEWALK/CURB SECTION 3000 PSI FIBER REINFORCED CONCRETE 2% SLOPE ° a Q n ° ALL SIDEWALKS TO HAVE SEALED ISOLATION JOINTS r SIDEWALKS TO HAVE BROOM FINISH RESERVED PARKING MAXIMUM PENALTY $250 12" 1/2 " ROUND ASPHALT PAVING SEE DETAIL am BOLLARD 2 cn UND CONC. TOP OF PE SMOOTH GA. STEEL BOLLARD -LED SOLID WITH 3000 ;I CONCRETE OVERED BY YELLOW PLASTIC 'ROVIDED BY OTHERS) VISH GRADE/PAVING CONCRET 3000 PSI N W U� B EC a_ 2i ,.11 0 Z� �� U ENGINEERING I PLANNING I ENVIRONMENTAL Q � v J 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LU >_ ���riirrrrr Lij �\U i H W m �/v .•ccNGINE��-�G�: � 60 W 09/17/2019 Z Q J W p� RqT •. � NCBELS#C-3448 U) 2 �'• '• 0 o ,'�• CAP •,` O 0 DETAILS PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/20�1908/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: NTS (H) (V) SHEET: C900 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. 1 C901 4 C901 NCDOT ASPHALT PAVING d d /1" nr (l(1 Cn DUMPSTER SCREENING 2 4 'I PACING 4x4 1X6 FRONT 2X4 TOP VIEW GATES SHALL BE CONSTRUCTED OUT OF STEEL FRAME TUBING WITH PIVOT HINGES MOUNTED ON 6" STEEL PIPE BOLLARDS. PROPER LATCHING AND LOCK HARDWARE SHALL BE PROVIDED IN ORDER TO RESTRAIN AND/OR LOCK ENCLOSURE GATES SHADOWBOX FENCING, I I \ ATTACHED WITH a' GALC. CARRIAGE BOLTS, (SOLID \ I I \ COLOR,' I I• . 2"-3" DIRT BACKFILL P I� i I I I�L,LL�, I ' PROVIDE SOLID 4" I SUPPORT WHEEL I I IF AND GALV. BRACKET U . 0.31 GATE PAINI PROVIDE SOLID 4" SUPPOI WHEEL AND GALV. BRACK WOOD GA I 12-0" 2x4 SPACE IF AN UNOBSTRUCTED VIEW EXISTS OF A RESIDENTIAL BUILDING BETWEEN TENANT PARCEL AND ADJACENT PARCEL, THEN LESSOR SHALL CONSTRUCT A PRIVACY FENCE IN ACCORDANCE WITH TENANT'S PROTOTYPE CRITERIA SET PLANS AND ANY APPLICABLE GOVERNMENTAL REQUIREMENTS. gill] 101 SIDE VIEW NOTE: 1. WOOD TO BE TREATED PINE. USE GALVANIZED NAILS FOR FASTENING. 2. NUMBER OF BOARDS WILL VARY DEPENDING ON SPACE BETWEEN BOARDS AND ACTUAL WIDTH OF BOARDS. - 4" DIA. SCHED. 40 PIPE W/SLOPED MTL. CAP ON TOP MAXIMUM 6-0" O.C. SET PIPE IN CONCRETE FOOTING MIN. V-0" DIA. TO FROST DEPTH (FILL PIPE W/CONC. TO 4'-0" ABOVE FIN. CONC. IN HIGH WIND LOAD LOCATIONS.) NOTES: 1. FOOTINGS SHALL EXTEND 3'-6" MINIMUM BELOW FINISH GRADE. 2. SEE CIVIL DRAWINGS FOR DUMPSTER ENCLOSURE LOCATION. 3. 8" THICK CONCRETE SLAB OVER 6" THICK CRUSHED AGGREGATE. 12"X12" THICKENED EDGE FOR APPROACH SLAB. #4 REBAR @ 2'-0" O.C. EACH WAY. 4. BOLLARDS IN TRASH ENCLOSURE TO BE PAINTED SAFETY YELLOW. 8" x 8" THICKENED EDGE GATE POSTS TO BE PAINTED BLACK EQ. EQ. 8" CONC. SLAB REINF. W/ W.W.F. 6"x6" - W2.9 TRASH ENCLOSURE PLAN x W2.9ON 6" AGGREGATE BASE IT d w 6" BOLLARDS GATE POSTS TO BE PAINTED BLACK 6" BOLLARDS o 00 w U w z C901 5 C901 7 C901 RECEIVING DOOR RAMP S L( STRIPING LEGEND YELLOW CURBING SURFACES SHOULD BE CLEAN, DRY AND METAL AND BOLLARDS - SURFACES FREE OF HEAVY RUST 2 COATS SHERWIN PARKING LOT WILLIAMS - KEM 4000 ACRYLIC ALKYD ENAMEL SAFETY YELLOW 355Y300 STRIPING - SURFACES SHOULD BE CLEAN, DRY. TOP COAT PARKING LOT SHERWIN WILLIAMS- PROMARTRAFFIC MARKING PAINT YELLOW TM5495 HANDICAP SURFACES SHOULD BE CLEAN, DRY. TOP COAT STRIPING - SHERWIN WILLIAMS- PROMARTRAFFIC MARKING PARKING LOT PAINT 'H.C." BLUE CONTRACTOR IS RESPONSIBLE FORALL PUBLIC UTILITY CONNECTIONS (ELECTRIC, WATER, GAS, SEPTIC, SEWER) AS WELL AS PROVIDING ALL INFRASTRUCTURES REQUIRED BY UTILITY COMPANY DEPRESSED CURB DROP INLET 3000 PSI CONCRETE APRON WITH 6X6 10/10 WWF GRATE AND FRAME (COLOR DARK GRAY) 5' TYP. USF 4139-6002 SLOPE % UNLESS SPECIFIED OTHERWISE O • a. ,• STEPS REQ'D FOR J� #4 BAR CONT 8" BOXES > 4' DEEP X ,� AT 10" O.C.+' "' O PRECAST BOX m w w 10, GRATE .. FOOTING BEYOND �U u.l z �� PRE -CAST BOX O o000 <' U GROUT SMOOTH Q ASPAHLT PAVING I oo ' > OR CONCRETE I oo AROUND PIPE .: Q 6 U (TYP.) VARIES � L�I— — —ILr _J . TO FIT PIPE O.D. AND GRATE INLET 3000 PSI CONCRETE 6" #57 STONE BASE -III=III- (COMPACTED) I=_I I CONCRETEAPRON I I�� NOTE: PIPEALIGNMENTS =1 I I=i - - , AROUND INLET SHOWN ARE EXAMPLES #4 BAR AT 8" O.C.E.W. 3 C901 6 C901 CONCRETE BRICK OR PRE -CAST BOX #4 BAR AT 8" O.C. E.W. 6" #57 STONE COMPACTED CONCRETE SIDEWALK JOINTS TOOLED JOINTS WITH JOINT SEALER CURB INLET 1" RADIUS UNLESS OTHERWISE SPECIFIED INLET FRAME & GRATE USF 5181-6420 FOR SAG INLETS & USF 5130-6431 FOR ON GRADE INLETS UNLESS SPECIFIED OTHERWISE CONC.GROUT J W U� B EC �• O � U ENGINEERING I PLANNING I ENVIRONMENTAL Q Cl) 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LL\J /_ k((Ilrr/ Lu U CAR % Lu W ` W �/v .•ccNGINE��-�G�: � '77�Il11111���\\ W 09/17/2019 Z Q • ........• P� •• Q � NCBELS#C-3448. U) �%i •'• '• Q' O. O ,'�• TH CARO 0 ���������HN�♦ 0 DETAILS PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: SHEET SIZE: 24" x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: NTS (H) (V) SHEET: C901 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. 1 C902 TEMPORARY GRAVEL CONSTRUCTION ENTRANCE GENERAL NOTES: 1. A STABILIZED ENTRANCE PAD OF COARSE AGGREGATE OR RAILROAD BALLAST SHOULD BE LOCATED WHERE TRAFFIC WILL ENTER OR LEAVE THE CONSTRUCTION SITE ONTO A PUBLIC STREET. 2. FILTER FABRIC OR COMPACTED CRUSHER RUN STONE SHOULD BE USED AS A BASE FOR THE CONSTRUCTION ENTRANCE. 3. THE ENTRANCE SHOULD BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC STREETS OR EXISTING PAVEMENT. THE MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS WARRANT AND REPAIR OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 4. ANY SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. 5. WHEN APPROPRIATE, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET. WHEN WASHING IS REQUIRED, IT SHOULD BE DONE IN AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN. 6. CDOT MAY REQUIRE A STANDARD COMMERCIAL DRIVEWAY TO ACCESS THE CONSTRUCTION SITE IF THE DRIVEWAY IS ON A THROUGHFARE. 7. PLEASE REFER TO NCESCPDM SECTION #6.06 FOR ADDITIONAL DESIGN SPECIFICATIONS REGARDING TEMPORARY GRAVEL CONSTRUCTION ENTRANCES/EXITS. MAINTENANCE NOTES: MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. 50' MIN 6" MIN PUBLIC STREET EXISTING GROUND SOIL STABILIZATION FABRIC UNDER 2-3" COARSE AGGREGATE 4 C902 NC VV NC DOT #5 OR #57 WASHED STONE 50' MIN -4mm& -Sam HARDWARE CLOTH AND GRAVEL INLET - PROTECTION 4' MAX ni 1A-C;[ IArF HARn\A/ARF C I nTH FILTERED WATER GENERAL NOTES: 1. REFER TO NCESCPDM SECTION #6.51 FOR ADDITIONAL DESIGN SPECIFICATIONS REGARDING HARDWARE CLOTH AND GRAVEL INLET PROTECTION. o z m p 100' TO 200' ROAD cp E" a i. HZ W20.-4 "Xa-" Q a ._ CD O D I 1 0 48" % 48' H c� Fommcn mz 20, 20' LLJaE EZ =� - m m ewc. WAX. � 0 o DI © C O D) tJJ = Z .. xm>>m ui<Qo= .3 cc z��oo fw LL' o ♦ O _ Z y ♦ ♦ WORK AREA y =O Q �Dy z Hm Ia © Id B b ® TIW-wnr DDWx N H H (n 0 i TRAFFIC STAEAW !� La C3 z 50' TAPER BUFFEfl NA%. 50'100' SPACE BUFFER TAPEfl SPACE 100' e T NE LAN � ROAD PREPARED TO STOP W20-4 W-;4 W20-7a 48" % 4, 48" % 48" 48" X 48" INSET FOR 2 LANE ROADWAYS N o WITH 2-WAY TURN LANE � D ALL OTHER DEVICES ARE THE SAME AS ABOVE co Q Y r- eat" CE- -E � W N O H sr WORK AREA CLOSED ♦ sr N 0-8 MIOX X Z Q .�. % 48" ♦ ♦ 98" ♦ 98" 4 3 J <mcn Q�r cr .� Z TWO-WAY TMFFIC I DOWN I SfWEPM 0 W Dr- O TAPER BUFFER BUFFER TAPER 0 Z 7Q 50'-100' SPACE SPACE f00' / Q v > D J O m o GENERAL NOTES FOR FLAGGER OPERATIONS GENERAL NOTES FOR PILOT CAR OPERATIONS z p 1- REFER TO STD. 1101.11 SHEET 4 FOR SIGN SPACING. 1- USE PILOT CARS WHEN DIRECTED BY THE ENGINEER. Q '. j 2 UPSTREAMLSIDECOFSTRAFFICTH THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE 2 ALONG AREA• ANDLATSTHEADISCRETION ( OFPTHE ENGINEER, CONES NOT BE OMIITTED ALONG Q D WORK O � 3- REMOVE LANE CLOSURES AGAINST THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE THE WORK AREA IF USING A PILOT CAR. _ 3: > Zy z DOWNSTREAM SIDE OF TRAFFIC. 3- CONES ARE ALWAYS REQUIRED IN THE UPSTREAM AND DOWNSTREAM TAPERS. co 0 m C Q 4- PLACE CONES THRU THE WORK AREA AT THE MAXIMUM SPACING EQUAL IN FEET TO 2 TIMES 4- MOUNT SIGN G20-4 "PILOT CAR FOLLOW ME" AT A CONSPICUOUS POSITION ON THE REAR OF N CL m THE POSTED SPEED LIMIT. THE PILOT VEHICLE. 0 F LLJ m o 5- EXTEND LANE CLOSURES AT THE BUFFER SPACE SUCH THAT STOPPING SIGHT DISTANCE IS 5- DO NOT INSTALL MORE THAN ONE (1) MILE OF LANE CLOSURE, MEASURED FROM THE BEGINNING Z W z co PROVIDED TO THE FLAGGER (REFER TO STD. 1101.11 SHEET 2). OF THE MERGE TAPER TO THE END OF THE LANE CLOSURE. W I� cp 6- DO NOT STOP TRAFFIC IN ANY ONE DIRECTION FOR MORE THAN 5 MINUTES AT A TIME. 6- ADVISE RESIDENTS AND BUSINESSES WITHIN THE LANE CLOSURE LIMITS ABOUT METHODS OF J m SAFE EGRESS AND INGRESS FROM DRIVEWAYS DURING FLAGGING AND PILOT CAR OPERATIONS. 7- DRUMS OR SKINNY -DRUMS MAY BE USED IN LIEU OF CONES. REFER TO ROADWAY STANDARD N DRAWING 1180.01 FOR SKINNY -DRUM REQUIREMENTS. 8- USE FLAGGERS TO CONTROL TRAFFIC AT INTERSECTIONS AFFECTED BY THE LANE CLOSURE. LEGEND SUPPLEMENT FLAGGERS LOCATED AT INTERSECTIONS WITH FLAGGER AHEAD SIGNS (W20-7a) PLACED APPROXIMATELY 250 FT. IN ADVANCE OF THE FLAGGER. FOR SIGNALIZED IF FLAGGER INTERSECTIONS PLACE SIGNALS IN THE FLASH MODE AND RECOMMEND THE USE OF LAW j CONE 9- 10- REFER TO 2009 MUTCD, CHAPTER 6, FOR FLAGGER CONTROL, REQUIREMENTS, AND PROCEDURES. DO NOT EXCEED A 1 MILE LANE CLOSURE LENGTH UNLESS OTHERWISE SHOWN IN THE TMP OR AS DIRECTED BY THE ENGINEER. IQ PORTABLE SIGN DIRECTION OF TRAFFIC FLOW HEET 1 OF 15 SHEET 1 OF 15 1101 .02 11101. 02 z C902 8' MAX WIRE FEN— - WOVEN FILTER FABF SILT FENCE I 30" MIN Q� o w E N J CI] L� I < 8" MIN STEEL POST WIRE FENCING FILTER FABRIC #57 STONE Q� 4? 3 C902 TEMPORARY DIVERSION nnnnnnnTrn WWII 2' MIN L- 4" MIN 1= 11 11 11 11 11 11 11 11 11� 11� 1 I I ! 11� 11� 11= GENERAL NOTES: I I- I IT50 Y ti I I� I I -' 11� I 11 11� l i I I� I I� I I� �� � �� � !� l l� I I� I I� I I I� I I� I I� 11=1 I I 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 950/c BY WEIGHT OF POLYOLEFINS OR 9. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. II�II= I I- III 1I- - '~ POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24INCHES. I I I I I I� I I� II THE REQUIREMENTS IN ASTM D 6461, WHICH IS SHOWN IN PART IN TABLE 6.62b. 10. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH ZIEE3.1 l2. SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. WIRE OR ,I I I~TO I I PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. GENERAL NOTES: TEMPERATURE RANGE OF 0 TO 120° F. 11. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE 1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS AND 3. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.25 LB/LINEAR FT MINIMUM STEEL WITH A PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. OTHER OBJECTIONABLE MATERIAL. MINIMUM LENGTH OF 5 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO 12. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL FACILITATE FASTENING THE FABRIC. 13. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. DESIGN REQUIREMENTS. 4. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. 14. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE 5. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH MAINTENANCE NOTES: DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. SYNTHETIC FILTER FABRICS. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSION TO PERMIT MACHINE 6. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE 1. INSPECT SEDIMENT FENCE AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REGARDING AND CLEANOUT. THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO REQUIRED REPAIRS IMMEDIATELY. 5. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL CAUSE FAILURE OF THE STRUCTURE.) 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECOME REMAIN IN PLACE LESS THAN 30 WORKING DAYS. 7. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE INEFFECTIVE, REPLACE IT PROMPTLY. MAINTENANCE NOTES: BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID 1. INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY 8. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UNDERMINING THE FENCE DURING CLEANOUT. RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE LOW AREA AND UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPS SLOPE SIDE OF THE TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUMPOUND TENSILE PROPERLY STABILIZED. STABILIZED, REMOVED THE RIDGE AND THE CHANNEL TO BLEND WITH THE STRENGTH. NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. 5 C902 CLASS B RIPRAP FLOW W 7 C902 ROCK O� RIPRAP PIPE INLET PROTECTION WASHED STONE GENERAL NOTES: 1. REFER TO NCESCPDM SECTION #16.55 FOR ADDITIONAL DESIGN SPECIFICATIONS REGARDING ROCK PIPE INLET PROTECTION. MAINTENANCE NOTES: ND ND 'HE IEN GN IN 'HE ED :EN 'HE 'HE STANDARD PIPE OUTLET TO WELL-DEFINED CHANNEL LA SECTION 'A -A' LA GENERAL NOTES: 1. LA= THE LENGTH OF THE RIPRAP APRON. 2. DA = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (INCHES). 3. IN A WELL-DEFINED CHANNEL EXTEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6" (INCHES) ABOVE THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS. 4. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. MAINTENANCE NOTES: INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. FILTER FABRIC 6 C902 8 C902 STONE OUTLET GENERAL NOTES: 1. STRUCTURAL STONE SHALL BE (CLASS B) STONE FOR EROSION CONTROL PURPOSES. 2. SEDIMENT CONTROL STONE SHALL BE #5 OR #57 STONE. STEEL FENCE POST #57 STONE SEDIMENT CONTROL STONE STRUCTURALSTONE 6" ROOF DRAIN �12 1'-6" MIN. II II II II u 3MAX. SPLASHBLOCK I� 1), RAAY II FRONT VIEW II II II u u c+ii T rrninr W B EC O U ENGINEERING I PLANNING I ENVIRONMENTAL Q Cl) 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LL\J LU U W oFESS/O'`�i� Lij _ �NGINe�- Cjj �\ G 09/17/2019 Z Q J RqT •. i NCBELSK-3448 i Cl) �%i •'• '• Q' : 1101. •, � •.....••'�� O z ,•• ,'�• CARo •,` ���������N•��♦ O 0 DETAILS PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: NTS (H/) (`) SHEET: C902 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. 1 C903 PL, INFLOW AVERAGE WIDTH * AREA OF SURFACE/ PRIMARY S INFLOW FILTER FABRIC SKIMMER SEDIMENT BASIN 1' rKtttiUHKU BAFFLES 6" MIN. INVERT ELEV. OF EMERGENCY SPILLWAY 2' DEWATERING r ZONE I ,f ARM ASSE"' " PERSPECTIVE VIEW PVC END CAP PVC ELBOW PVC END CAP PVC PIPE 1/2" HOLES IN PVC TEE UNDERSIDE END VIEW FLEXIBLE HOSE 1' SEDIMENT J CLASS B STONE PAD STORAGE ZONE (4' x 4' x 1' MIN.) CROSS-SECTION VIEW WATER SURFACE SCHEDULE 40 PVC PIPE PVC VENT PIPE 6 FRONT VIEW PVC TEE RGENCY _LWAY EMBANKMENT EMERGENCY SPILLWAY "C" ENCLOSURE FER ENTRY f NOTE: 1. ALL SKIMMERS SHALL BE FAIRCLOTH SKIMMERS UNLESS OTHERWISE SPECIFIED. SCHEDULE 40 PVC PIPE ORIFICE PLATE BOTTOM SURFACE GENERAL NOTES: 1. CLEAR, GRUB AND STRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY, VEGETATION, ORGANIC MATTER AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER THE FILL EMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS. PREVENT THE SKIMMING DEVICE FROM SETTLING INTO THE MUD BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT UNDER THE SKIMMER OF STONE OR TIMBER. 4. PLACE THE BARREL *TYPICALLY 4-INCH SCHEDULE 40 PVC PIPE) ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL OR CRUSHED STONE AS BACKFILL AROUND THE PIPE. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM THE FIRM CONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. 5. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURES INSTRUCTIONS OR AS DESIGNED. 6. LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOIN TO THE BARREL PIPE AND POSITION THE SKIMMER OVER THE EXCAVATED PIT OR SUPPORT. BE SURE TO ATTACHED A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE FOR MAINTENANCE. 7. EARTHEN SPILLWAYS - INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH LAMINATED PLASTIC OR IMPERMEABLE GEOTEXTILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOM AND SIDES AND EXTEND ONTO THE TOP OF THE DAM FOR ANCHORING IN A TRENCH. THE EDGES MAY BE SECURED WITH 8-INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUST BE ON PIECE, NOT JOINED OR SPLICED; OTHERWISE THE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC IS INSUFFICIENT FOR THE ENTIRE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS, SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTION(S) SHOULD OVERLAP THE LOWER SECTIONS(S) SO THAT WATER CANNOT FLOW UNDER THE FABRIC. SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A TRENCH WITH STAPLES OR PINS. 8. INLET - DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSION WITH OUTLET PROTECTION TO DIVERT SEDIMENT LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY. 9. EROSION CONTROL - CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM THE BARE AREAS. COMPLETE THE EMBANKMENT BEFORE THE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION. 10. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65. 11. AFTER ALL THE SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY. MAINTENANCE NOTES: 1. INSPECT SKIMMER SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVED SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE FIRST BAFFLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED. EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKIMMER OR THE FIRST CELL. MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. 2. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE -ANCHOR THE BAFFLES IF WATER IS FLOWING UNDERNEATH OR AROUND THEM. 3. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING ON THE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE IF IT IS CLOGGED; IF SO REMOVE THE DEBRIS. 4. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. 5. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. 6. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. z C903 INLET PLAN VIEW FENCE AND FABRIC BURIED IN TRENCH 6"X6" TRENCH, BACKFILLED AND COMPACTED SECTION VIEW AT OPENING STEEL POST 2' BAFFLE GENERAL NOTES: 1. BAFFLE MATERIAL SHOULD BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR SILT FENCE. 2. MOST OF THE SEDIMENT WILL ACCUMULATE IN THE 1 ST BAY, WHICH SHOULD BE READILY ACCESSIBLE FOR MAINTENANCE. 3. PROVIDE 3 BAFFLES (USE TWO IF LESS THAN 20 FEET IN LENGTH). PROVIDE 5 BAFFLES FOR DRAINAGE AREAS GREATER THAN 10 ACRES. 4. BAFFLE SHALL BE 700 G/M2 COIR EROSION BLANKET. 5. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS. 6. INSPECT BAFFLES FOR REPAIR ONCE A WEEK AND AFTER EACH RAINFALL. 7. PLEASE REFER TO NCESCPDM SECTION #6.65 FOR ADDITIONAL DESIGN SPECIFICATIONS REGARDING BAFFLES. OUTLET MAINTENANCE NOTES: 1. INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OF A BAFFLE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS WHEN IT REACHES HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE BAFFLES. TAKE CARE TO AVOID DAMAGING THE BAFFLES DURING CLEANOUT. SEDIMENT DEPTH SHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. 4. AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED, REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO GRADE AND STABILIZE IT. SUPPORT ROPE TO WIRE TO PREVENT SAGGING SUPPORT POST, 24" INTO BOTTOM OR SIDE STAKE TO SUPPORT WIRE LCOIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE E&SC PERMANENT SEEDING SCHEDULE. * DO NOT USE WITHIN 25RIPARIAN BUFFER. SEE RIPARIAN SEEDING SCHEDULE FOR BUFFER SEEDING SPECS SEEDING MIXTURE SPECIES RATE (LB/ACRE) TALL FESCUE 100 SERICEA LESPEDEZA 20 KOREAN LESPEDEZA 10 REDTOP 5 KENTUCKY BLUEGRASS 5 SEEDING NOTE 1. AFTER AUGUST 15. USE UNSCARIFIED SERICEA LESPEDEZA SEED. 2. WHERE APPEARANCE IS A CONSIDERATION, OMIT SERCIA LESPEDEZA AND INCREASE KOREAN LESPEDEZA TO 40 LB/ACRE. NURSE PLANTS BETWEEN MAY 1 AND AUGUST 15 ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE TALL FESCUS, PRIOR TO MAY 1 OR AFTER AUGUST 15, ADD 40 LB/ACRE RYE GRAIN. IT MAY BE BENEFICIAL TO PLANT THE GRASSES IN LATE SUMMER AND OVERSEED THE LESPEDEZA IN MARCH. SEEDING DATES BEST POSSIBLE BELOW 2500 FT: AUG 15-SEP 1 JULY 25-SEP 15 MAR 1 -APR 1 MAR 1- MAY 10 ABOVE 2500 FT: JULY 25- AUG 15 JULY 15-AUG 30 MAR 20 - APR 20 MAR 5-MAY 15 COMPLETE SEEDING EARLIER IN THE FALL, AND START LATER IN THE SPRING ON NORTH AND EAST FACING SLOPES. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS OR APPLY 4000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1000 LB/ACRE 5-10-10 FERTILIZER. MULCH APPLY 4000-5000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCHING MATERIAL. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR ROVING. NETTING IS THE PREFERRED ANCHORING METHOD ON STEEP SLOPES. MAINTENANCE REFERTILIZE THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MOW NO MORE THAN ONCE PER YEAR. RESEED, FERTILIZE, AND MULCH DAMAGED AREAS IMMEDIATELY. SOIL PREPARATION: SOIL TEST: SOIL TESTING WILL DETERMINE WHETHER THE SOIL PH AND NUTRIENT (PHOSPHORUS, POTASSIUM, CALCIUM AND MAGNESIUM) LEVELS ARE IN A RANGE THAT FAVOR TURFGRASS GROWTH. THE SOIL TEST REPORT WILL INDICATE NEEDED AMOUNTS OF FERTILIZER AND/OR LIME. CLEAN AND ROUGH GRADE: REMOVE ALL DEBRIS FROM THE LOCATION TO BE PLANTED. THIS INCLUDES ROCKS, BOTTLES, LARGE ROOTS AND OLD TREE TRUNKS. IF EXTENSIVE GRADING IS NEEDED, REMOVE THE TOPSOIL AND STOCKPILE IT FOR REPLACEMENT AFTER THE ROUGH GRADE IS ESTABLISHED. THE SUBSURFACE MAY BECOME COMPACTED DURING ROUGH GRADING, ESPECIALLY IF THE GROUND IS WET. THIS COMPACTED LAYER MUST BE BROKEN UP. A SPRING -TOOTH HARROW WORKS WELL ON LIGHTLY COMPACTED SOILS; A SMALL ROTOTILLER MAY BE NEEDED FOR MORE HEAVILY COMPACTED SITES. DEEP TILLAGE: ROTOTILLING LOOSENS COMPACTED SOIL AND IMPROVES THE SPEED AND DEPTH OF ROOTING. A TRACTOR -MOUNTED OR SELF-PROPELLED TILLER WILL ADEQUATELY TILL THE SOIL. TAKE CARE NOT TO DESTROY THE EXISTING TREES IN THE LAWN. CUTTING TOO MANY TREE ROOTS DURING SOIL TILLAGE CAN SEVERELY DAMAGE OR KILL A TREE. TREES CAN ALSO BE SUFFOCATED BY DEEPLY COVERING THE ROOTS WITH SOIL. IF ADDITIONAL SOIL IS NECESSARY AT A TREE BASE, CONSTRUCT A "TREE WELL." REPLACE THE TOPSOIL: ONCE THE SUBSURFACE IS ESTABLISHED, RETURN THE TOPSOIL AND SPREAD UNIFORMLY OVER THE ENTIRE AREA. ALLOW FOR AT LEAST 6 TO 8 INCHES OF DEPTH AFTER THE SOIL HAS SETTLED. THIS MEANS PLACING ABOUT 8 TO 10 INCHES OF TOPSOIL OVER THE SUBSURFACE. IMPROVE THE SOIL BY ADDING ORGANIC MATTER. THIS IMPROVES WATER RETENTION IN SANDY SOILS AND DRAINAGE IN CLAY SOILS AND REDUCES FERTILIZER LEACHING. CONTINUOUS LINES 10'-30'/SP SKIP LINE 2'-6'/SP MINI -SKIP LINE Z m O i -� UNLESS OTHERWISED SHOWN, USE 10'-30'/SP SKIPS FOR UNLESS OTHERWISED SHOWN, USE 2'.6'/SP MINI -SKIPS FOR F-Q py Z m N O SKIP LANE LINES AND SKIP CENTER LINES. LANE LINE EXTENSIONS THROUGH INTERSECTIONS, EDGE LINE EXTENSIONS THROUGH INTERSECTIONS AND MINI -SKIPS Q Q. H py O �, EDGE LINE 10' USED FOR BICYCLE LANE LINES. H O U 30' O = O YELLOW OR WHITE Q fn =m> m Q o 4"/s" 2' 6' FUqU_x Cn O 10-1 LANE LINE YELLOW OR WHITE o o a"/s" ��LLzo J <, = z 4"/6" YELLOW OR WHITE cc O O Tn ' D D WHITE Z Fti 3'-3'/SP MINI -SKIP LINE 3'-9'/SP MINI -SKIP LINE m~ w �� Z CENTER LINE UNLESSOTHERWISED SHOWN, USE 3'-3'/SP MINI -SKIPS FOR UNL THE WHITE EDGE LINE ENTENSIONS AT ROUNDABOUTS. UNLESS OIHERWISED SHOWN, USE 3'-9'0P MINI -SKIPS FOR MINI -SKIP LANE LINES AND LINE EXTENSIONS THROUGH TAPERS. Lu 0 YELLOW T 4"/6" T GORE LINE 3 3' 3 9 8"112 12„ WHITE WHITE WHITE m DIAGONAL LINE 1 112" 45 MPH OR HIGHER � UL U) Ir-I Ir-i z O B" LESS THAN 45 MPH z rr7 W m 4 = YELLOW OR WHITE 7 y Z co __4 m �MLL Cr) �ma Qm L oo�0 m z zz CROSSWALK LINE o z D o0 WHITE 8" TRANSVERSE T 24" LONGITUDINAL OL Q Z T Z W m0 ¢LuCL coW ~ Z H RXR LINE my�z -i 0 y 16„ rnaco Hti H'' O _n WHITE J J O z m Lu STOP OR TRANSVERSE BA A GENERAL NOTES: 1• USE 6" LANE, EDGE, AND CENTER LINES ON ALL FULL CONTROL OF ACCESS FACILITIES AND OTHER ROUTES 24" AS DIRECTED 8Y THE ENGINEER. WHITE 2- LANE LINES INDICATED AS "WIDE" ON THE ROADWAY STANDARD DRAWINGS SHALL BE AT LEAST TWICE THE WIDTH OF THE NORMAL LINE. 3• GORE LINES SHALL BE TWICE THE WIDTH OF THE NORMAL LINE. SHEET 1 OF 2 SHEET 1 OF 2 1205.01 1205.01 3 C903 PAVED AREAS ICK, 12" DIA. ;.APRON PAVING SUB -PAVING - GRAVEL BASE COMPACTED OR UNDISTURBED SOIL - CLEANOUT PAVED AREAS (2-WAY CLEANOUT) SICK, 24"x24" C.APRON COMPACTED OR UNDISTURBED SOIL AO JOSAM SERIES 58860-22 ACCESS COVER AND CLEANOUT WITH TAPER THREAD BRONZE PLUG SERIES 58540-20 AND "SAN." ON COVER (OR APPROVED EQUIVALENT). OB NEENAH MODEL R-6660-DP LIGHT DUTY ACCESS COVER WITH TWO (2) JOSAM SERIES 58190-22 CLEANOUTS WITH TAPER THREAD BRONZE PLUG SERIES 58540-20 (OR APPROVED EQUIVALENT). PRECAST CONCRETE POURED IN PLACE OF CONCRETE COLLAR SCH. 40 PVC CAP LANDSCAPED AREAS SCH. 40 PVC E&SC TEMPORARY SEEDING SCHEDULE. * DO NOT USE WITHIN 25RIPARIAN BUFFER. SEE RIPARIAN SEEDING SCHEDULE FOR BUFFER SEEDING SPECS LATE WINTER & EARLY SPRING (FEB 15-MAY 15) SOIL PREPARATION: SPECIES RATE (LB/ACRE) SOIL TEST: SOIL TESTING WILL DETERMINE WHETHER THE SOIL PH AND NUTRIENT (PHOSPHORUS, POTASSIUM, CALCIUM AND MAGNESIUM) LEVELS RYE GRAIN 120 ARE IN A RANGE THAT FAVOR TURFGRASS GROWTH. THE SOIL TEST REPORT AND WILL INDICATE NEEDED AMOUNTS OF FERTILIZER AND/OR LIME. KOREAN LESPEDEZA 50 SUMMER (MAY 15-AUGUST 15) SPECIES RATE (LB/ACRE) GERMAN MILLET 40 OR TALL FESCUE 50 FALL (AUGUST 15-DECEMBER 15) SPECIES RATE (LB/ACRE) RYE GRAIN 120 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TEST OR APPLY 2000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. INCREASE FERTILIZER RATE TO 1000 LB/ACRE IN THE FALL. MULCH APPLY 4000-5000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OR ANOTHER SUITABLE MULCHING MATERIAL. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IN NOT FULLY ADEQUATE. RESEED, FERTILIZER, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TOPDRESS WITH 50 LB/ACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/ACRE KOREAN LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. CLEAN AND ROUGH GRADE: REMOVE ALL DEBRIS FROM THE LOCATION TO BE PLANTED. THIS INCLUDES ROCKS, BOTTLES, LARGE ROOTS AND OLD TREE TRUNKS. IF EXTENSIVE GRADING IS NEEDED, REMOVE THE TOPSOIL AND STOCKPILE IT FOR REPLACEMENT AFTER THE ROUGH GRADE IS ESTABLISHED. THE SUBSURFACE MAY BECOME COMPACTED DURING ROUGH GRADING, ESPECIALLY IF THE GROUND IS WET. THIS COMPACTED LAYER MUST BE BROKEN UP. A SPRING -TOOTH HARROW WORKS WELL ON LIGHTLY COMPACTED SOILS; A SMALL ROTOTILLER MAY BE NEEDED FOR MORE HEAVILY COMPACTED SITES. DEEP TILLAGE: ROTOTILLING LOOSENS COMPACTED SOIL AND IMPROVES THE SPEED AND DEPTH OF ROOTING. A TRACTOR -MOUNTED OR SELF-PROPELLED TILLER WILL ADEQUATELY TILL THE SOIL. TAKE CARE NOT TO DESTROY THE EXISTING TREES IN THE LAWN. CUTTING TOO MANY TREE ROOTS DURIN SOIL TILLAGE CAN SEVERELY DAMAGE OR KILL A TREE. TREES CAN ALSO BE SUFFOCATED BY DEEPLY COVERING THE ROOTS WITH SOIL. IF ADDITIONAL SOIL IS NECESSARY AT A TREE BASE, CONSTRUCT A "TREE WELL." REPLACE THE TOPSOIL: ONCE THE SUBSURFACE IS ESTABLISHED, RETURN THE TOPSOIL AND SPREAD UNIFORMLY OVER THE ENTIRE AREA. ALLOW FOR AT LEAST 6 TO 8 INCHES OF DEPTH AFTER THE SOIL HAS SETTLED. THIS MEANS PLACING ABOUT 8 TO 10 INCHES OF TOPSOIL OVER THE SUBSURFACE. IMPROVE THE SOIL BY ADDING ORGANIC MATTER. THIS IMPROVES WATER RETENTION IN SANDY SOILS AND DRAINAGE IN CLAY SOILS AND REDUCES FERTILIZER LEACHING. o STRAIGHT ARROW RIGHT OR LEFT COMBINATION STRAIGHT AND COMBINATION LEFT AND z o m TURN ARROW LEFT OR RIGHT TURN ARROW RIGHT TURN ARROW Tn 0 rO ~ m U Z = D 20" 6, 4„ 96 6„ 20 38 SAME DIMENSIONS APPLY AS FOR THE LEFT/RIGHT TURN ARROW F QF3 z = O O m z H 500�n� U) xmDyrn aFv0o�o_n ]R=40"- COMBINATION LEFT AND STRAIGHT�o�¢a mM114" AND RIGHT TURN ARROW z°� v dH,-�O 4" 32 4" BAME DIMENSIONS APPLY AS FOR THE COMBINATION STRAIGHT AND LEFT/RIGHT TURN ARROW 12" R-40" 32° 12" 12 R-28" 6'-4" MERGE ARROW RAMP ARROW Zm FOR WRONG -WAY MOVEMENTS ON FREEWAY AND EXPRESSWAY RAMPS W W F p0 > o o _ry, CRYSTAL/RED 5'_p„ PAVEMENT MARKER C7 cc clu O 'C = B„ ,.I,P Z. CC oZZ v N 6„ _ _ - _ _ _ _ _ - _ _ - _ _ - _ _ _ _ _ - _ - _ _ _ _ _ _ OF RAMP on IN In on D p zo 2'_s" S 6„ a Q T' o~o o ° 5'D" zZz o m ry' - nP. 2'-6" Q 11J <t m 7' .1" Do uzj J y co Q m m 00 GENERAL NOTES: 1- USE THE COLOR WHITE FOR ALL PAVEMENT MARKING SYMBOLS. 100 * A EXITRAMR RAMP J } W 2- DO NOT LOCATE PAVEMENT MARKING SYMBOLS AS TO ENCROACH INTO INTERSECTION AREAS. 3- DO NOT PLACE PAVEMENT MARKING SYMBOLS ACROSS TRANSVERSE EXPANSION JOINTS ON PORTLAND CEMENT CONCRETE PAVEMENTS, « UNLESS APPROVED BY -fHE ENGINEER. 4- CONFORM ALL SYMBOLS TO THE FHWA "STANDARD ALPHABETS FOR 7AT HIGHWAY SIGNS AND PAVEMENT MARKIIIGS", (REFER TO SHEETS 5 THRU 8). SYMBOL DIMENSIONS CAN VARY AMONG MANUFACTURERS, THEREFORE SLIGHT VARIANCES ARE ACCEPTABLE, HOWEVER, ALL P ARROW IT RAMP HEFT i OF 7p SHEET 1 OF B 1 205.0E SYMBOLS ARE REQUIRED TO HE APPROVED BY THE DEPARTMENT. 1p0Y 1 205 . 08 W U� B EC O ��. SQ; U ENGINEERING I PLANNING I ENVIRONMENTAL Q U) 126 EXECUTIVE DRIVE - SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz W Lij U :1` CARP '''� W c _ ✓ �% Lu C%) 6 ` )VGINE� 'G: :D 09/17/2019 Z Q J �. PO .• RqT •. Q KBELSK-34481 U) ?i �'• '• Q' : •, ,Qtoo' •.....••'�� O z ��• ,'�• T CARo o , O 0 DETAILS PREPARED FOR: TERAMORE DE PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: NTS (H) M SHEET: C903 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE. 1 C904 ROLLED EROSION CONTROL MATTING INSTALLATION FIGURE F FIGURE B/ . FIGURE E STEP 1 - SITE PREPARATION FIGURE C FIGURE E / ^ '` :;, FIGURE C PREPARE SITE TO DESIGN PROFILE AND GRADE. REMOVE DEBRIS, ROCKS, BLANKET 3 ' CLODS, ETC.. GROUND SURFACE SHOULD BE SMOOTH PRIOR TO FIGURE C , �'�t INSTALLATION TO ENSURE BLANKET REMAINS IN CONTACT WITH SLOPE. :.�:.. /.. ^ :• . .�:.•� BLANKET 1 ^ - STEP 2 - SEEDING SEEDING OF SITE SHOULD BE CONDUCTED TO DESIGN REQUIREMENTS OR TO :',', , ...:.'':•;.' •+" FOLLOW LOCAL OR STATE SEEDING REQUIREMENTS AS NECESSARY. �/ ^ ^ ::,, :.' FIGURE F ' BLANKET 2 ` STEP 3 - STAPLE SELECTION " i GROUND AT A MINIMUM, 6" LONG BY 1" CROWN, 11 GAUGE STAPLES ARE TO BE USED TO t, SURFACE SECURE THE BLANKET TO THE GROUND SURFACE. INSTALLATION IN ROCKY, , �, ;:;.: •,: '';,' `., ' �, •�' SANDY OR OTHER LOOSE SOIL MAY REQUIRE LONGER STAPLES. - ::.4-':: STEP 4 - EXCAVATE ANCHOR TRENCH AND SECURE BLANKET • f" FIGURE B/ M1 FIGURE E EXCAVATE A TRENCH ALONG THE TOP OF THE CHANNEL SIDE SLOPES AND - :'NGURED ::.'.,:`�:'•:::`=::'' '�• ': THE UPSTREAM TERMINAL END OF THE CHANNEL TO SECURE THE EDGES OF :•:: :' ".`•' THE BLANKET. THE TRENCH SHOULD RUN ALONG THE LENGTH AND WIDTH OF BLANKET 3 THE INSTALLATION, BE 6" WIDE AND 6" DEEP. STAPLE BLANKET ALONG ;-;''.;•; ''' ;, ",: ' ;' '; ', . :., : '. ,..' ': "` ' ..:::i• .^ :.??BGfKE::= : '' ° < '` BOTTOM OF TRENCH, FILL WITH COMPACTED SOIL, OVERLAP BLANKET GROUND - ',� M1" ;•; - -.' �:'' , •, :� :: ''' TOWARDS TOE OF SLOPE AND SECURE WITH ROW OF STAPLES (SHOWN IN > : SURFACE "? FIGURES A, H, E AND F). FIGURE I STEP 5 - SECURE BODY OF BLANKET :.....:.. .. . , . M. •. .... ' �"''' '`` f' *SLOPE INSTALLATION - APPROXIMATELY 200 STAPLES PER ROLL (8' OR 4' ROLL BLANKET DOWN SLOPE FROM ANCHOR TRENCH. STAPLE BODY OF *BED INSTALLATION -APPROXIMATELY 300 STAPLES PER ROLL (8' WIDTH) REQUIRED - WIDE BLANKET SHOWN BLANKET FOLLOWING THE PATTERN SHOWN IN FIGURE D AND I. LEAVE END OF OR 4' WIDTH) REQUIRED - WIDE BLANKET SHOWN BLANKET UNSTAPLED TO ALLOW FOR OVERLAP SHOWN IN FIGURE B. PLACE DOWNSTREAM BLANKET UNDERNEATH UPSTREAM BLANKET TO FORM SHINGLE PATTERN. STAPLE SEAM AS SHOWN IN FIGURE E. SECURE DOWNSTREAM BLANKET WITH STAPLING PATTERN SHOWN IN FIGURE D AND I. STAPLING PATTERN SHOWN IN FIGURE D AND I REFLECTS MINIMUM STAPLES TO BE USED. MORE STAPLES MAY BE REQUIRED TO ENSURE BLANKET IS SUFFICIENTLY SECURED TO RESIST MOWERS AND FOOT TRAFFIC AND TO ENSURE BLANKET IS IN CONTACT WITH SOIL SURFACE OVER THE ENTIRE AREA OF BLANKET. FURTHER, CRITICAL POINTS REQUIRE ADDITIONAL STAPLES. CRITICAL POINTS ARE IDENTIFIED IN FIGURE G AND J. STEP 6- CONTINUE ALONG SLOPE - COMPLETE INSTALLATION OVERLAP ADJACENT BLANKETS AS SHOWN IN FIGURE C AND REPEAT STEP 5. SECURE TOE OF SLOPE USING STAPLING PATTERN SHOWN IN FIGURE E. SECURE EDGES OF INSTALLATION BY STAPLING AT 1.0' INTERVALS ALONG THE TERMINAL EDGE. MAINTENANCE NOTES: 1. INSPECT ROLLED EROSION CONTROL PRODUCTS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAIN FALL EVENT REPAIR IMMEDIATELY. 2. GOOD CONTACT WIT THE GROUND MUST BE MAINTAINED, AND EROSION MUST NOT OCCUR BENEATH THE RECP. 3. ANY AREAS OF THE RECP THAT ARE DAMAGED OR NOT IN CLOSE CONTACT WITH THE GROUND SHALL BE REPAIRED AND STAPLED. 4. IF EROSION OCCURS DUE TO POORLY CONTROLLED DRAINAGE, THE PROBLEM SHALL BE FIXED AND THE ERODED AREA PROTECTED. 5. MONITOR AND REPAIR THE RECP AS NECESSARY UNTIL GROUND COVER IS ESTABLISHED. 4 C904 FIGURE F- PROFILE VIEW FIGURE A - BED INSTALLATION BLANKET 3 ..►... ►' .� .mild GROUND SURFACE FIGURE B - PROFILE VIEW FLOW 3" BLANKET 1 BLANKET 2 GROUND SURFACE FIGURE C - CROSS SECTION VIEW CREST OF CREST OF SLOPE SLOPE TOE OF SLOPE i FIGURE G- CRITICAL POINTS - BED INSTALLATION N-12 HDPE STORM TRENCH INSTALLATION RECOMMENDED MINIMUM TRENCH WIDTHS' FINAL = BACKFILL 0 Z z 0 �w j w > O Q 0 w � z t co i INITIAL SPRINGLINE BACKFILL HAUNCH 4" FOR 12"-24" PIPE 6" FOR 30"-60" PIPE BEDDING MIN. TRENCH WIDTH SUITABLE NOTES: (SEE TABLE) FOUNDATION 1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, "STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS", LATEST ADDITION 2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN REQUIRED. 3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL. 4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I, II OR III. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4" (100mm) FOR 4"-24" (100mm-600mm), 6" (150mm) FOR 30"-60" (750mm-900mm). 5. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I, II OR III IN THE PIPE ZONE EXTENDING NOT LESS THAN 6" ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION. 6. MINIMUM COVER: MINIMUM COVER, H, IN NON -TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" FROM THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOATION. FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE AND 24" OF COVER FOR 54"-60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID PAVEMENT. PIPE DIAM. MIN. TRENCH WIDTH 4" 21" 6" 23" 8" 26" 10" 28" 12" 30" 15" 34" 18" 39" 24" 48" 30" 56" 36" 64" 42" 72" 48" 80" 54" 88" 60" 96" MINIMUM RECOMMENDED COVER BASED ON VECHICLE LOADING CONDITIONS SURFACE LIVE LOADING CONDITION PIPE DIAM. H-25 HEAVY CONSTRUCTION (75T AXLE LOAD) 12"-48" 12" 48" 54" - 60" 24" 60" VEHICLES IN EXCESS OF 75T MAY REQUIRE ADDITIONAL COVER MINIMUM RECOMMENDED COVER BASED ON RAILWAY LOADING CONDITIONS COOPER PIPE DIAM. E-80** UP TO 24" 24" 30"-36" 36" 42"-60" 48" COVER IS MEASURED FROM TOP OF PIPE TO BOTTOM OF RAILWAY TIE. E-80 COVER REQUIREMENTS, ARE ONLY APPLICABLE TO ASTM F 2306 PIPE. FIGURE E FIGURE H - SLOPE INSTALLATION X- DENOTES STAPLE LOCATION FIGURE D - PLAN VIEW- BED INSTALLATION FIGURE I - PLAN VIEW - SLOPE INSTALLATION 5 C904 8" _ 1" _x_ 1" 1" x_ 1" 1" x_ 1" _x_ 1" 1" 4" 1 _x_ 1 -x- 1 x- 1 FIGURE E- PLAN VIEW CRITICAL POINT CRITICAL POINT TERMINAL END GROUND GROUND SURFACE SURFACE FIGURE J - CRITICAL POINT SECURING - SLOPE INSTALLATION TEMPORARY EXCLUSION FENCE FENCE MATERIAL: ORANGE, UV RESISTANT HIGH TENSILE STRENGTH POLYETHYLENE LAMINAR 2 C904 BMP OUTLET RIM ELEV. = 820.75 r" ° <. GROUT INTERIOR ° 3" ORIFICE WALLS c' INV. = 819.05 STORM RAX PEAK <.g. ROOF STRUCTURE 3' x 3' PRE -CAST TRASH RACK CATCH BASIN A A 4" PVC ` INV. IN = 815.00 tr 15" HDPE INV. OUT = 815.00 ° d_ 6" #4 BAR AT 8" O.C.E.W. 4' W x 4' L x 9" D 3,000 PSI CONCRETE F L- FOOTING BEYOND NOTES: 1. ENSURE ALL STRUCTURE JOINTS AND PIPE PENETRATIONS ARE WATERTIGHT. USE BUTYL SEALANT OR OTHER GASKET METHOD TO SEAL JOINTS BETWEEN STRUCTURE SECTIONS. GROUT INTERIOR STRUCTURE WALLS AND PIPE CONNECTIONS. 3 C904 822.00 TOP OF DAM 12" CLASS A RIPRAP SHWT = BELOW 800 (SEE GEO-TECH REPORT) NOTES: 1. UNLESS COVERED BY BLANKET EASEMENT, SAND FILTER SHALL HAVE A MINIMUM 20 FOOT ACCESS EASEMENT CONNECTING TO A DEDICATED PUBLIC RIGHT OF WAY. ACCESS ROAD SHALL HAVE A MIN. 12, STABILIZED WIDTH, MAX. LONG, GRADE OF 15% MAX., CROSS SLOPE 5%. 2. ALL DRAINAGE AREAS TO THE SAND FILTER ARE TO BE STABILIZED PRIOR TO INSTALLATION OF AMENDED SAND, MULCH OR PLANTING. 3. PVC UNDERDRAIN PIPE SHOULD HAVE 3/8" PERFORATIONS SPACED AT 6" CENTERS. MIN. 4 HOLES PER ROW. MAX SPACING OF UNDERDRAIN PIPE IS 10 FEET ON CENTER. 4. UNDERDRAIN CLEANOUTS SHOULD MATCH UNDERDRAIN PIPE SIZE AND EXTEND A MIN. OF 6" ABOVE SAND SURFACE. 7 OUTLET STRUCTURE SEE DETAIL r i J 822.00 TOP OF DAM .GENCY SPILLWAY ELEV. 821.00 818.00 TOP OF SAND 15" HDPE OUTLET 815.00 2 4" PERFORATED PVC UNDERDRAINS @ 0.5% SLOPE 12" OF #57 STONE L 18" OF COURSE MASONRY SAND CONFORMING TO ASTM C33 STANDARD ALL MATERIAL LAYERS TO BE SEPARATED BY 80Z NON -WOVEN GEO-TEXTILE FILTER FABRIC SCREW CAP W U� B EC LU LU _j 0 SQ U ENGINEERING I PLANNING I ENVIRONMENTAL 126 EXECUTIVE DRIVE -SUITE 220 Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LLJ Lij i .� xNH CARLU 9 ; = Q� W A 5 ` U) �/v . ccNGINE�Q- .•G� ` � C. cN� 09/17/2019 z J �• PO •• RqT •. Q U : NCBELS#C-3448 * U) ?i �'• '• Q' : •, ,Q ' •.....•ON; 0 z ��• ,'�• CAR •,` ���������HN�♦ O 0 DETAILS PREPARED FOR: TERAMORE DE' PO BOX 6460 THOMASVILLE, JELOPMENT, LLC GA 31758 DATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 08/01/2019 PROJECT NUMBER: 3160542019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: NTS (H/) (`) SHEET: C904 © COPYRIGHT 2019 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE.