Loading...
HomeMy WebLinkAboutWQ0041101_Application (FTSE)_20190924Permit Number WQ0041101 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRuIe Permitted Flow Facility Name Evolve Surf City Crossing Apartments Public Sewer Location Address Owner Owner Name Town of Surf City Dates/Events Central Files: APS _ SWP _ 8/14/2019 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County Fender Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation Ashley Loftis PO Box 2475 Surf City NC 28445247 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 8/12/2019 Regulated Activities Requested /Received Events Additional information requested Additievinl mfn..+.a6nn .venl..e.i ���® ® L -1, OUNTE E N G 1 N E E R 1 N G. I N C. 1 2 2 C I N E M A D R I V E W I L M I N G T O N, N C 2 8 4 0 3 9 1 0- 7 9 1- 6 7 0 7( O) 9 1 0- 7 9 1- 6 7 6 0 ( F; L E T T E R O F T R A N S M I T T A L To: NCDHQ Date 08/01/19 127 N. Cardinal Drive Wilmington, NC 28405 Re: Evolve Surf City Crossing 910 796-7215 Fast Track Sewer Attn: Dean Hunkele Pro'ect No. I 18445.PE e are sendin ® Originals ® Prints ❑ Shop Drawings ❑ Calculations ❑ Correspondence ❑ Plans ❑ Specifications ❑ Other as listed below he followin items: Quantity Date Dwg. No. Description 2 Fast Track Sewer Permit FTA 04-16 (Public) 2 Fast Track Sewer Permit FTA 04-16 (Private) 2 Flow Tracking/Acceptance Sewer Extension Application FTSE 04-16 1 Sanitary Sewer Narrative with USGS Map & Site Map 2 $480 checks (public & private) Issue Status: ® For Approval ❑ As Requested ❑ Construction ❑ Bid ❑ For Your Use ® For Review and Comment ❑ Approved as Noted ❑ See Remarks ction Taken: ❑ No Exceptions Taken ❑;Make Corrections Noted ❑ Amend & Resubmit ❑ Rejected - See Remarks ❑ Approved as Submitted ❑ Other emarks: Cc: Fast Track Sewer Submittal Evolve Surf City Crossing Signed: AUG 12 2019 hi RECEIVED/NCDENR/M AU 2019 ater Quality Regional Operations Section Wilmington Regional Office State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: Wl). 6 I101 (to be completed byDWR) All Items must be completed or the anolication will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Surf City (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name; Ashley Loftis per 15A NCAC 02T .0106(b) Title: Town Manager 4. Applicant's mailing address: 214 N. New River Drive, PO Box 2475 City: Surf City State: INC Zip:28445- 5. Applicant's contact information: Phone number: (910) 328-4131 Email Address: aloftisna townofsurfcity.com 11. PROJECT INFORMATION: 1111� 1. Project name: Evolve Surf City Crossing ?G_MI<, 5—e—t—tt✓ 2. Application/Project status: ® Proposed (New Permit) ❑ Existing PermidProject If a modification, provide the existing permit number: W000_ and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Ponder 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.4637550 Longitude:-77.572772' 5. Parcel ID (if applicable): 4225-07-7336 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Tim Clinkscales License Number: 028847 Firm: Parantounte Engineering. Inc. Mailing address: 122 Cinema Drive City: Wilmington State: NC Zip: 28403-_ Phone number: (910) 791-6707 Email Address: telinkscales(aparamounte-eng.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Surf City WWTF High -Rate Infiltration and Wastewater Irri ation System Permit Number: W00000795 Owner Name: Town of Surf City V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W00034188 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00278 Owner Name(s): Town of Surf City FORM: FTA 04-16 Page I of 5 V1. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [-]No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM; DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Hontc/Property Owners' Association has an Operational Agreement (FORM: HOA) been attached? ❑ Yes []No ®N/A 4. Origin of wastewater: (check all that apply) ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ® Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: IQQ%Domestic/Commercial _%Commercial _I % Industrial (See 15A NCAC 02'r .0103(20)) �— is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ® No If yes, orovide a cony of flow reduction annroval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.01140 Daily Design Flow •A No. of Units Flow gal/ GPD gal/ GPD gal/ GPD gall GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02'r .0114(b). (d). (e)(I) and (g)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified (in table 15A NCAC 02T.01 Id] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ® Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: F'rA 04.16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 650 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Y Section III contains information related to minimum slopes for gravity sewer(s) Y Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vlll. PUMP STATION DESIGN CRITERIA (if Applicable) — 02T.0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design now of the pump station: _ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at _ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(l)(B)_ Y Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Y Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .03050hx 1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): Y It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. Y If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timefmmes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS -(02B.0200&ISA NCACO2T.0305(1)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (e) 1 I SA mrar n2T 010S(f) enntnins minimum nenarations that shall be provided for sewer systems: ►5 ■ --------- -- - Setback Parameter" Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class II impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item 1X.2 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Anv buildinp foundation 5 feet Any basement 10 feet Top sloe of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimminp pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02'r.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ "Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ if noncompliance with 02T.0305(f) or (a). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ➢ Seethe Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This would include Trout Buffered Streams per I SA NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitling Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional pennits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [-]Yes ® No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and Inspections documented per 15A NCAC 02T.0403(a)(5) or the permltee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02 t•, the Minimum Design Criteria for the Pennittipg of Ptunp Stations and lFQce Mains (latest version). and the tavjLy-Sewer Minimum_Desien Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and sunnortina documents 2. Professional EMteer'se(`ncllC� I, l lI��JJ (Professional Engineer's name from Applicat that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting or pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a tine not to exceed S 10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signnture, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): that this application for name R title from A ftlication Ilem 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 343-215.6A and 14 -2_ 15.6t3, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: 41A.A &Q4�b Date: -j-31_iy FORM: FTA 04-16 Page 5 of 5 EVOLVE SURF CITY CROSSING TOWN OF SURF CITY SANITARY SEWER DESIGN NARRATIVE Prepared for: EVOLVE COMPANIES 2918-A MARTINSVILLE ROAD GREENSBORO, NC 27408 Prepared by: -D A RAMOUNTE r 122 Cinema Drive Wilmington, NC 28403 Project#18445.PE August 2019 PROTECT NARRATIVE The property served by this proposed sewer extension is located approximately 900 LF from the intersection of Alston Boulevard and Hwy 210 behind the Harris Teeter Shopping Center and before the Arbors residential subdivision. Evolve Companies is developing the 33.5 acre parcel into 336 apartments in 14 (24 unit) buildings along with a clubhouse and amenity facilities. The project will be divided into 2 phases, with Alston Boulevard being the phase limits. The flow for Phase 1 will be 49,370 gpd as provided in the attachment. This flow will be collected via a gravity sewer system. For the permit, the gravity sewer for phase 1 will consist of both public and private lines, with 650 LF of public 8" gravity and 900 LF of private 8" gravity, as shown in the attachments. Lastly, the project contains gravity lines and manholes which are within 50' of wetlands. The plans require and show pipe materials and testing to meet watermain standards and for manholes to be fully lined with waterproof material and vacuum tested for these sections. a `v '� ¢ 7 i :a • ¢; e � c Google Maps 34°27'49.5"N 77°34'22.0"W C 8 J Tire and_Q Auto Repair y � .ems ,r. a v 01 s� 0 pl, n-v S trO+4q �Sd $tryd Old Landing Child Care4 �Au Surf City Tire Auto v F�q �bdd'ka �moi qtl Share the Table 9 °p'*o'gy' npi Ur+'0.e MADp PO T S �F S Google s„ d _ Map data 02019 500 ft r 8/14/2019