Loading...
HomeMy WebLinkAboutWQCS00372_NOV-2019-PC-0645_20190924 a ROY COOPER Gmrmar MICHAEL S.REGAN `• Secretay •ey"" � LINDA CULPEPPER NORTH CAROLINA Duccrar Environmental Quality September 24,2019 CERTIFIED 1yiAII,7017 0190 0000 9562 7374 RETURNED RECEIPT REQUESTED Mr.Michael J. Myers,Managing Partner Old North State Water Company,LLC 4700 Homewood Court Suite 108 Raleigh,NC 27609 Subject: Notice of Violation—Notice of Intent to Enforce NOV-2019-PC-0645 Briar Chapel Subdivision Collection System Permit Number WQCS00372 Dear Mr.Myers: This Notice of Violation — Notice of Intent to Enforce is in regards to the numerous Sanitary Sewer Overflows (SSOs) that have occurred from Briar Chapel Subdivision's Wastewater Collection System. The system is owned/operated by Old North State Water Company, LLC, and operates under permit WQCS00372. According to the most recently issued Collection System Permit that became effective on August 1, 2018, the system includes approximately 9.13 miles of gravity sewer and approximately 7.31 miles of force main. Below is a list of SSOs in Briar Chapel that have been self-reported by Old North State Water Company, LLC. since July 2017: North Carolina Department of Environmental Quality I Division of Water Resources 1628 Mail service Center,Raleigh,NC 27699-1628 ,919-791-4200 Mr.Michael J.Myers,Old North State Water Co.,LLC NOV-2019-PC-0645 September 24,2019 Page 2 of 4 Self- Self Incident Incident Source of Estimated Estimated e Number Start Date Overflow Incident Location Volume Volume Cause (Gallons) to Waters (gallons) 201701165 7/12/2017 Sanitary 75Hi11creekBlvd 5000 5000 Other/Pipe Sewer Failure 201701784 1 12/24/2017 Pump 1690 Great Ridge 500 500 Pipe Failure Station Parkway - Sanitary Forcemain Behind 380 201801334 8/15/2018 Sewer -and 390 Beacon Ridge 1000 300 Other Rd from Lift Station D PS Failure/ 201803141 10/12/2018 Pump Turtle Point Bend Lift 200 200 Severe Station Station Natural Conditions Sanitary FM behind home on 201803499 11/14/2018 .Sewer 440 Old piedmont Cr 2000 1000 Other from LS D Sanitary 1690 Great Ridge 201900237 I/27l2019 Sewer Parkway 100 100 PS Failure 201900781 4/18/2019 Pump LS B 1058 Great 1000 200 Grease Station Ridge Parkway 201901001 6/5/2019 Sanitary 480 Beacon Ridge 1000 500 Other Sewer Blvd Sanitary MH Lift station Great 201901062 6111l2019 Sewer Ridge Parkway 2000 2000 Pipe Failure 201901249 7/16/2019 Sanitary Lift station behind 75 4000 4000 Pipe Failure Sewer Hill Creek Blvd Sanitary 52 Hill Creek Blvd 201901312 7/31/2019 Sewer Chapel Hill,NC 500 500 Other 201901350 8/12/2019 Sanitary 75 Hill Creek Blvd, 200 200 Pipe Failure Sewer Chapel Hill NC Sanitary 300 N Serenity Hill 201901423 9/1/2019 Sewer Cir, Chapel Hill,NC 1500 0 Pipe Failure 27516 201901481 9/7/2019 Sanitary 75 Hill Creek Blvd 4000 4000 Pipe Failure Sewer The frequency of SSOs from this collection system relative to the size of the system,as well as the numerous spills that have occurred on the same force main, is a violation of Condition I.2 of Briar Chapel's Wastewater Collection System Permit: Mr.Michael J.Myers,Old North State Water Co.,LLC NOV-2019-PC-0645 September 24,2019 Page 3 of 4 Condition 1.2(Performance Standards)of the Wastewater Collection System Permit(WQCS00372)states: "The wastewater collection system shall be effectively managed, maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. In the event that the wastewater collection system fails to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate actions as per lie Response Action Plan (Condition II(9)), as well as any actions that may be required by the Division of Water Resources (Division), such as the construction ofadditional or replacement sewer lines and/or equipment[15ANCAC 02t 0108(b)]" Please answer the following questions: 1. Please provide a list of any spills that were below the reportable thresholds that were not self- reported. 2. Several of the more recent spills appeared to be caused by pipe failures in the area around Hill Creek Boulevard. Please provide details and possible reasons for the cause of the pipe breaks. 3. Please explain what has already been done to address these spills. 4. Please provide a corrective action plan on what will be done in the future to prevent SSOs. 5. Please explain how often the Operator in Responsible Charge (ORC) visits this site and inspects the pump station and foreemains, and what is done on these inspections. 6. Please provide testing documentation for the forcemains installed at the Briar Chapel subdivision. You are required to take any necessary action to correct the above violations and to provide a written response to this Notice within thirty(30)days of receipt. Please include in your response all corrective actions already taken and a schedule for completion of any corrective actions not addressed. As a result of the violations in this Notice, our office is considering a recommendation for the assessment ofa civil penalty. Ifyou wish to present an explanation for dre violations cited, or ifyou believe there are other factors which should be considered,please send such information tome in writing within thirty (30) days following receipt of this letter. Your response will be reviewed and taken into consideration prior to the assessment of any civil penalty. Mr.Michael J.Myers,Old North State Water Co,LLC NOV-2019-PC-0645 September 24,2019 Page 4 of 4 Failure to comply with conditions in a permit may result in a recommendation of enforcement action,to the Director of the Division of Water Resources who may issue a civil penalty assessment of not more that twenty-five thousand($25,000)dollars against any"person'who violates or fails to act in accordance with the terms, conditions, or requirements of a permit under authority of G.S. 143-215.6A. Sincerel , h Assistant Su, ervisor P Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources,NCDEQ cc: Chatham County Environmental Health