Loading...
HomeMy WebLinkAboutWQ0029635_Compliance Evaluation Inspection_20190919ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director NORTH CAROLINA Environmental Quality September 20, 2019 Sunset Point at High Rock Lake HOA, LLC 52 Sunset Pointe Dr. Salisbury, North Carolina 28146 Attention: Shane Wolford Subject: Surface Irrigation Inspection Report Permit No. WQ0029635 Facility: Sunset Pointe WWTP Rowan County Dear Mr. Wolford: Enclosed you will find the report for the compliance inspection that was conducted on September 17, 2019. The treatment and disposal systems appear to be operating satisfactorily. The system appears to be in compliance with the permit. As discussed on site during the inspection, the potential future addition of non -domestic wastewater flow from a separate source such as a restaurant would require a permit modification. The attached inspection report should be self-explanatory. However, should you have any questions or concerns regarding the report, please feel free to contact me at 704-235-2198 or via email at Edward.watsongncdenr. _ og_v. However, should you have any questions, please feel free to contact me at 704-235-2198 or by email at edward.watsonAmcdenngov. Sincerely, DocuSigned by: A H Nuft F161 F669A2D84A3... Andrew H. Pitner, P.G. Assistant Regional Supervisor Mooresville Regional Office Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosure: Inspection Report CC: Lynn Aldridge, rowanwastewater@gmail.com (via email) D Q � North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 NOAn-icJwauNn i nwm,em of eem­woviRv 704,663.1699 Compliance Inspection Report Permit: WQ0029635 Effective: 03/01/15 Expiration: 02/29/20 owner: Sunset Pointe on High Rock HOA LLC SOC: Effective: Expiration: Facility: Sunset Pointe WWTP County: Rowan 7460 Goodman Lake Rd Region: Mooresville Salisbury NC 28146 Contact Person: Michael O'Connell Title: Phone: Directions to Facility: From 1-85 and Long Ferry Rd (exit 81) travel east approx. 3 miles on Long Ferry Rd. At intersection with Goodman Lake Rd, turn right and travel south 0.6 miles. Entrance to WWTP is on the right. System Classifications: SI, Primary ORC: A Lynn Aldridge Certification: 993778 Phone: 704-431-5266 Secondary ORC(s): On -Site Representative(s): Corporate Responsible Official Related Permits: Inspection Date: 09/17/2019 Primary Inspector: Edward Watson Secondary Inspector(s): Shane Wolford Entry Time: 09:45AM Exit Time: 11:30AM Reason for Inspection: Routine Permit Inspection Type: Wastewater Irrigation Facility Status: Compliant ❑ Not Compliant Question Areas: Phone: Inspection Type: Compliance Evaluation Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Treatment Filters Use Records Record Keeping Treatment Lagoons End Use -Irrigation Treatment Disinfection Treatment Flow Measurement (See attachment summary) Page 1 of 6 Permit: WQ0029635 Owner - Facility: Sunset Pointe on High Rock HOA LLC Inspection Date: 09/17/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On September 17, 2019 MRO staff conducted a Compliance Evaluation Inspection of the Sunset Point HOA community WWTP under permit W00029635. The facility was found to be in compliance with the conditions of the permit. Page 2 of 6 Permit: WQ0029635 Inspection Date: 09/17/2019 Owner - Facility: Sunset Pointe on High Rock HOA LLC Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Reuse (Quality) ❑ Activated Sludge Spray, HR ❑ Single Family Spray, LR ❑ Activated Sludge Drip, LR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Activated Sludge Spray, LR ❑ Infiltration System ❑ Lagoon Spray, LR Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: A review of the treatment system was performed during the site visit. The system appeared to be operating within the specifications of the permit. Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ 0 ❑ Is flowmeter operating properly? ❑ ❑ 0 ❑ Does flowmeter monitor continuously? ❑ ❑ 0 ❑ Does flowmeter record flow? ❑ ❑ 0 ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Comment: Influent flow measurements are not required at this time. Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? ❑ ❑ 0 ❑ Are the daily average values properly calculated? ❑ ❑ 0 ❑ Comment: Water use measurement is not a component of this permit. Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Page 3 of 6 Permit: WQ0029635 Owner - Facility: Sunset Pointe on High Rock HOA LLC Inspection Date: 09/17/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Comment: The flow meter has not been calibrated within the last year. However, it was mentioned during the site visit that flow can be calculated and the calculated flow could be checked to determine if the calculated flow was within the 10% error alotted for the flow meter and therefore, within the permit. The ORC will provide the calculated flow to the MRO. Treatment Filters Yes No NA NE Is the filter media present? 0 ❑ ❑ ❑ Is the filter media the correct size and type? 0 ❑ ❑ ❑ Is the air scour operational? ❑ ❑ 0 ❑ Is the scouring acceptable? ❑ ❑ ❑ Is the clear well free of excessive solids? ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? ❑ ❑ ❑ Does backwashing frequency appear adequate? ❑ ❑ 0 ❑ Comment: Filter media is washed manually as required. Only two of the Advantex pod units are currently in service as the development has not reached the designed capacity. Treatment Disinfection Yes No NA NE Is the system working? ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time (-30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1000- If yes, then when was the RMP last updated? Comment: Disinfection is obtained by UV. The UV treatemnt system was reviewed durina the site visit. The ORC keeps back-up bulbs on site to be able to keep the treatment system running properly. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ Page 4 of 6 Permit: WQ0029635 Owner - Facility: Sunset Pointe on High Rock HOA LLC Inspection Date: 09/17/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine NDAR? 0❑ ❑ ❑ Are flow rates less than of permitted flow? 0❑ ❑ ❑ Are flow rates less than of permitted flow? 0❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ ❑ Are Operational and Maintenance records present? ❑ ❑ ❑ Were Operational and Maintenance records complete? ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ ❑ No treatment units bypassed since last inspection? ❑ 0 ❑ ❑ Comment: GW was elevated for Fecal Coliform. This could be the results of a sample collection error. The GW was low in the wells at the time of the sampling event. The ORC was instructed to bail the well and wait 24 hours for the well to recovery prior to sampling. The 2019 soils report will be sent to MRO by email. End Use -Irrigation Are buffers adequate? Is the cover crop type specified in permit? Is the crop cover acceptable? Is the site condition adequate? Is the site free of runoff / ponding? Is the acreage specified in the permit being utilized? Is the application equipment present? Is the application equipment operational? Yes No NA NE ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ 01100 01100 01100 Page 5 of 6 Permit: WQ0029635 Owner - Facility: Sunset Pointe on High Rock HOA LLC Inspection Date: 09/17/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the disposal field free of limiting slopes? Is access restricted and/or signs posted during active site use? Are any supply wells within the CB? Are any supply wells within 250' of the CB? How close is the closest water supply well? Is municipal water available in the area? # Info only: Does the permit call for monitoring wells? Are GW monitoring wells located properly w/ respect to RIB and CB? Are GW monitoring wells properly constructed, including screened interval? Are monitoring wells damaged? Comment: The application is currently only utilizing two permitted fields due to the low flow entering the system. The monitoring wells appeared to be in good condition during the site visit. • ❑ ❑ ❑ • ❑ ❑ ❑ ❑■❑❑ ❑■❑❑ ❑❑❑■ ❑■❑❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑■❑❑ Page 6 of 6