HomeMy WebLinkAboutWQ0041167_Application (FTSE)_20190920State of North Carolina
DW Department ofEnvironmental Quality
Division of Water Resources
15A NCAC 02T .0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
°Dhislon of Water Resources INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION
This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been
certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's
Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, 15A
NCAC 02T, 15A NCAC 02T .0300, Division policies and good engineering Practices.
While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design
documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design
calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These
documents shall be available upon request by the Division.
Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A�pA N22
NCAC 00T.T.0303.
Projects not eligible for review via the fast track process (must be submitted for full technical revi�p
'' "'1 .�
➢ Projects that require an environmental assessment in accordance with 15A
➢ Projects that do not meet any part of the minimum design criteria (MDC) document;
➢ Projects that involve a variance from the requirements of 15A NCAC 2T; AUG 3 0 2019
➢ Pressure sewer systems utilizing septic tank -effluent pumps (STEPS) or simplex grinder pumps;
➢ STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains);
➢ Vacuum sewer systems. WatOr QW11ty Replonal Oporatl011s
General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items
are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and
reduce the amount of requested additional information. Failure to submit all required items will necessitate additional
processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit
one original and one copy of the application and supporting documentation.
A. One Original and One Copy of Application and Supporting Documents
® Required unless otherwise noted
R. Cover Letter (Required for AR Application Packages):
® List all items included in the application package, as well as a brief description of the requested permitting action.
➢ Be specific as to the system type, number of homes served, flow allocation required, etc.
➢ If necessary for clarity, include attachments to the application form.
C. Application Fee (All New and Major Modification Application Packages):
® Submit a check or money order in the amount of $480.00 dated within 90 days of application submittal.
➢ Payable to North Carolina Department of Environmental Quality (NCDEQ)
D. Fast Track (Form: FTA 04-16) Application (Required for AR Application Packages):
® Submit the completed and appropriately executed application.
➢ If necessary for clarity or due to space restrictions, attachments to the application may be made.
® If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with
the North Carolina Secretary of State.
❑ If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of
Deeds in the county of business.
® The Project Name in Item II.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc.
® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North
Carolina licensed Professional Engineer.
® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b),
Per ISA NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is
provided from a person who meets the criteria in 15A NCAC 02T .0106(b).
INSTRUCTIONS FOR FORM: ETA 04-16 & SUPPORTING DOCUMENTATION Pagel of 3
E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable):
❑ Submit the completed and executed FTSE form from the owners of the. downstream sewers and treatment facility.
➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different.
➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one
year prior to the application date.
➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143-
215.67(a).
D Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE.
F. Site Maps (All Application Packages):
® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project
area and closest surface waters.
D Location of the project (gravity sewer, pump stations & force main)
➢ Downstream connection points and permit number (if known) for the receiving sewer
® Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field.
G. Existing Permit (Ali Modification Packages):
❑ Submit the most recently issued existing permit.
❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit
modification (i.e., permit description, flow allocation, treatment facility, etc.).
H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station):
❑ Per 15A NCAC 02T .0305(h)(1), submit documentation of power reliability for pumping stations.
➢ This alternative is only available for average daily flows less than 15,000 gallons per day
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible
with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed
contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated
appurtenances and personnel are available for distribution and operation of this pump station."
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump
stations' storage capacities and the rotation schedule of the portable power source or pump, including travel
timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification)
I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities):
❑ Per 15A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina
Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by
the sewer extension, or
❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an
application for a franchise has been received and that the service area is contiguous to an existing franchised area or that
franchise approval is expected.
Operational Agreements (Applications from HOA/POA and Developers for lots to be sold):
❑ Home/Property Owners' Associations
❑ Per 15A NCAC 02T .0115(c), submit the properly executed Operational Agreement (FORM: HOA).
❑ Per 15A NCAC 02T ,0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws.
❑ Developers of lots to be sold
❑ Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM: DEV).
For more information, visit the Division's collection systems website
INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3
THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND
MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE:
REGIONAL OFFICE
ADDRESS
COUNTIES SERVED
Asheville Regional Office
2090 US Highway 70
Avery, Buncombe, Burke, Caldwell, Cherokee,
Water Quality Section
Swannanoa, North Carolina 28778
Clay, Graham, Haywood, Henderson, Jackson,
(828) 296-4500
Macon, Madison, McDowell, Mitchell, Polk,
(828)299-7043 Fax
Rutherford, Swain, Transylvania, Yancey
Fayetteville Reolonal Office
226 Green Street Suite 714
Anson, Bladen, Cumberland, Harnett, Hoke,
Water Quality Section
Fayetteville, North Carolina 28301-5094
Montgomery, Moore, Robeson, Richmond,
(910) 433-3300
Sampson, Scotland
(910)486-0707 Fax
Mooresville Reatonal Office
610 E. Center Avenue
Alexander, Cabamus, Catawba, Cleveland,
Water Quality Section
Mooresville, North Carolina 28115
Gaston, Iredell, Lincoln, Mecklenburg, Rowan,
(704)663-1699
Stanly, Union
(704)663-6040 Fax
Raletah Regional Office
1628 Mail Service Center
Chatham, Durham, Edgecombe, Franklin,
Water Quality Section
Raleigh, North Carolina 27699-1628
Grenville, Halifax, Johnston, Lee, Nash,
(919) 791-4200
Northampton, Orange, Person, Vance, Wake,
(919) 788-7159 Fax
Warren, Wilson
Washinaton Regional Office
943 Washington Square Mall
Beaufort, Bartle, Camden, Chewer, Craven,
Water Quality Section
Washington, North Carolina 27889
Cuff !tuck, Dare, Gales, Greene, Hertford, Hyde,
(252) W-6481
Jones, Lenoir, Martin, Pamlico, Pasquotank,
(252) 975-3716 Fax
Perquimans, Pitt, Tyrrell, Washington, Wayne
Wilminaton Regional Office
127 Cardinal Drive Extension
Brunswick, Carteret, Columbus, Duplin, New
Water Quality Section
Wilmington, North Carolina 28405
Hanover, Onslow, Ponder
(910)796-7216
(910)350-2004 Fax
Winston-Salem Regional OfFce
450 W. Hanes Mill Road
Suite 300
Alamance, Allegheny, Ashe, Caswell, Davidson,
Davie, Forsyth, Guilford, Rockingham, Randolph,
Water Quality Section
Winston-Salem, North Carolina 27105
Stokes, Sorry, Watauga, Wilkes, Yadkin
(336)776-9800
INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3
State of North Carolina
DWR Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
` Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: (to be completed by DwR)
All items must be completed or the application win be returned
I. APPLICANT INFORMATION:
1. Applicant's time: Crest Residential, LLC (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual Z Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ❑ Municipal ❑ Other
3. Signature authority's name: Bentley Nelson per 15A NCAC 02T .0106(b)
Title: Pry C3 `\
4. Applicant's mailing address: 500 Office Park Dr. Ste. 215 RIAUG
57
City: Birmingham State: AL Zip: 35223-3 0 2099
5. Applicant's contact information:
Phone number: 205)567-1467 Email Address: bentley(dcrestres.com Water Quality Regional Operations
H. PROJECT INFORMATION: Asheville Regional Office
1. Project name: The Holston
2. Application/Project status: Z Proposed (New Permit) ❑ Existing Permit/Project
If a modification, provide the existing permit number: W000 and issued date: _
If new contraction but part of a master plan, provide the existing permit number: WO
3. County where project is located: Buncombe
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.709V Longitude:-82.58193°
5. Parcel fD (if applicable): 9733-62-6052
(or Parcel ID to closest downstream sewer)
IH. CONSULTANT INFORMATION:
1. Professional Engineer: M. Scott Homewood License Number: 036336
Firm: Civil Design Contents
Mailing address: 168 Patton Ave
City: Asheville State: NC Zip: 28801
Phone number: 8( 28) 252-5388 Email Address: shi mewood(cuodceo.com
IV. WASTEWATER TREATMENT FACILITY(WWTF) INFORMATION:
1. Facility Name: MSD of BC Permit Number: 2019133
Owner Name: MSD of BC
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch
System Wide Collection System Permit Number(s) (i£ applicable): WQCS00004
Owner Name(s): MSD of BC
FORM: ETA 04-16 Page 1 of 5
V1. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience
and Necessity been attached?
❑ Yes ❑No ®N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEVI been attached?
❑ Yes ❑No ®N/A
3. If the Applicant is a Home/Property
Owners' Association. has an Operational Agreement (FORM: HOAI been attached?
❑ Yes ❑No ®N/A
4. Origin of wastewater: (check all that
apply):
❑ Residential Owned
❑ Retail (stores, centers, malls)
® Cm Wash
® Residential Leased
❑ Retail with food preparation/service
❑ Hotel and/or Motels
❑ School / preschool / day care
❑ Medical / dental / veterinary facilities
® Swimming Pool /Clubhouse
❑ Food and drink facilities
❑ Church
❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories
❑ Nursing Home
❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Commercial %Commercial
I % Industrial (See 15A NCAC 02T .0103(20))
"Is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Hasa flow reduction been approved under 15A NCAC 02T .01 14(f)7 []Yes ® No
➢ If yes, provide a copy of flow reduction approval letter
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114fD1
Daily Design Flow ens
No. of Units
Flow
Apartments
240 gal/1 Bedroom
108
25,920 GPD
Apartments
240 gat/2 Bedroom
105
25,200 GPD
Apartments
360 gat/3 Bedrooms
24
8,640 GPD
Car Wash Bay
1200 gat/bay
1
1,200 GPD
Swimming Pool
10 gat/person
100
1000 GPD
gat/
GPD
Total
61,960 GPD
a See 15A NCAC 02T .01 14(b) (d) (e)(l) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 61960 GPD (per 15A NCAC 02T .0114)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Number: _
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain):
FORM: FTA 04-16 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches) Length (feet) Material
8 1408 DIP
➢ Section If & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable)-02T .0305 & MDC (Pump Stations/Force Mainsl:
1. Pump station number or name: Private on -site
2. Approximate Coordinates (Decimal Degrees): Latitude: 35.7091' Longitude:-82.58193'
3. Design flow of the pump station: .0372 millions gallons per day (four capacity)
4. Operational point(s) of the pump(s): 80 gallons per minute at 27 feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches)
Length (feet)
Material
3
805
PVC
6. Power reliability in accordance with 15A NCAC 02T.0305(h)(1):
® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B),
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IS. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)):
1. Does the project comply with all separations Found in 15A NCAC 02T .0305(f) & (a) ® Yes ❑ No
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below vertical
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer
18 inches
Reclaimed water lines horizontal - reclaimed over sewer
2 feel
**Any private or public water supply source, including any wells, WS-1 waters of Class I or
Class It im ounded reservoirs used as a source of drinking water
100 feet
**Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal
high water or tide elevation and wetlands see item IX.2
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches -
10 feet
Any building foundation
5 feel
Any basement
10 feet
Top sloe of embankment or cuts of 2 feet or more vertical height
10 Feet
nd intercefr drains
5 feet
ADr
i 10 feet
Final earth grade vertical
36 inches
➢ 15A NCAC 02T.0305(g) contains alteratives where separations in 02T.0305(ft cannot be achieved.
➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weboage
➢ If noncompliance with 02T.0305(f) or Nk see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Yes ❑ No ❑ N/A
D See the Division's draft separation requirements for situations where separation cannot be meet
D No variance is required if the alternative design criteria specified is utilized in design and construction
➢ As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A
➢ This would include Trout Buffered Streams per 15A NCAC 211.0202
4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No
individual permits or 401 Water Quality Certifications?
➢ Information can be obtained from the 401 & Buffer Permitting Branch
5. Does project comply with 15A NCAC 02T 0105(c)(6) (additional permits/certifications)? ® Yes [-]No
Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes ❑ No ® N/A
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections
documented per 15A NCAC 02T.0403(a)(5) or the permher's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains :(latest version), and the Gravity Sewer Minimum DeslamCriteria (latest version). as applicable?
® Yes ❑ No
If No, complete and submit the Variance/Altennative Design Request application (VADC 10-14) and supporting documents for
review. Approval of the request is required prior to submittal ofthe Fast Track Application and supporthor documents:
2. Professional Engineer's Certification:
5,0 )))0 M attest that this application for
(Professional Engineer's name from Application Item 111.1.)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although otherprofessionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed 510,000, as well as civil penalties up to $25,000 per violation.
nui
North Carolina Professional Engineer's seal, signature, and date o' C A RO'�., i
p 115ESS/0*-!k - i
=o°CY3,
° SEAL
�a 03 33�
9F< °S. H0�F.
3. Applicant's Certification per 15A NCAC 02T.0106(b):
f,so n ` ?r; ^ r_1p 4 attest that this application for
Authority's name & title from Application Item 1.3.)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition
of this permit be violated. I also understand that if all required parts of this application package are not completed and that if
all required supporting information and attachments are not included, this application package will be returned to me as
incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature: aG. ✓VIiL X� Date: 6 q, / l %
FORM: FTA 04-16 Page 5 of
Civil
Design
D Concepts, PA
Transmittal
Date: August 30, 2019
Project Name: The Holston
CDC Project: 11858
To: Timothy Hein
Water Quality Regional Operations Engineer
NCDEQ-Asheville
2090 D.S. 70 Highway
Swannanoa, NC 28778-8211
Ell C3D
AUG 3 0 2019
fter Quality Regional Operations
Asheville (Regional Office
Via Mail _ Overnight _ Hand Delivered x Pick up @ CDC Office _
.____Copies-----
_____Date__
1
8/30/19
2
8/30/19
2
8/30/19
2
8/30/19
2
8/30/19
.___._..__'...............
_.
8/20/19
REMARKS:
Descri tion
p- -
CDC Cover Letter q,
---------------------------------------------------------------------------------
One Orig One Copy Fast Track Sewer Application
One Orig One Copy Technical Specifications
One Orig One Copy Design Calculations
___________— ----- ______.._...._._._._._.__._..._...........................
24" x 36" Sewer Plans
-----------------------------------------------------------------------------------
Review Fee Check of $480
Scott Homewood, P.E.
somewood@cdcgo.com
Mailing Address: P.O. Box 5432, Asheville, NC 28813
168 Patton Avenue, Asheville, NC 28801 52 Walnut Street— Suite 9, Waynesville,NC 28786
Phone 828-252-5388 Fax 828.252.5365 Phone: 828-452-4410 Fax: 828-456-5455
CD�Co�i e�Pb�PA
August 30, 2019
Timothy Heim
Water Quality Regional Operations Engineer
NCDEQ-Asheville
2090 U.S. 70 Highway
Swannanoa, NC 28778-8211
RE: The Holston
CDC Project No.: 11858
Dear Mr. Heim,
I
Water Quality Regional Operations
Asheville Regional Office
On behalf of Crest Residential, LLC we are requesting your review and approval of a sewer fast
track application for the subject project. The proposed project consists of privately maintained
single duplex pump station, approximately 800 linear feet of 3" force main, 1,376 linear feet of
privately maintained 8" gravity sewer and other appurtenances connecting to 32 linear feet of
proposed 8" public gravity sewer to serve a portion of the proposed 237(currently 234 but with
proposed small parcel addition will be 237) unit apartment complex located at 135 Monticello
Road in Weaverville. Please find enclosed the following items for your review and approval:
• Fast Track Sewer Application
• Sewer Plans
• Specs
• Design Calculations
• Review Fee Check of $480
If you should have any questions or need any additional information during your review, please
do not hesitate to call our office.