Loading...
HomeMy WebLinkAboutNC0033685_Inspection_20190919EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0033685 19/09/19 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Mountain Glen Golf Club Mtn Glen Resort Newland NC 28657 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:30AM 19/09/19 16/08/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Joshua Kenneth Cagle/ORC// Other Facility Data 11:00AM 19/09/19 21/02/28 Name, Address of Responsible Official/Title/Phone and Fax Number Vickie Daniels,PO Box 326 Newland NC 286570326//828-733-5809/8287333615 Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss DWR/ARO WQ/828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 65012A70-0B1C-4784-815D-DFC48DFD0649 9/19/2019 9/19/2019 NPDES yr/mo/day 19/09/19 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 9/19/2019, I (Daniel Boss) met with Jadd Brewer (Backup ORC) at the Mountain Glen Golf Club WWTP and conducted a compliance evaluation inspection. Overall the facility appeared to be operating well and maintained adequately. The permit lists a comminutor in the components list. This is incorrect and should be replaced with "manual bar screen" in the permit. There is no dechlorinator. The ORC drops dechlorination tablets into a post chlorination wet well/manhole to dechlorinate the effluent. This appears to be effective, however some sort of tablet feeding tube/device would be preferred. NC0033685 17 (Cont.) Page#2 DocuSign Envelope ID: 65012A70-0B1C-4784-815D-DFC48DFD0649 Permit:NC0033685 Inspection Date:09/19/2019 Owner - Facility: Inspection Type: Mountain Glen Golf Club Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? The permit lists a comminutor as a component, which the plant does not have. The permit does not list a bar screen, which the plant does have. Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Page#3 DocuSign Envelope ID: 65012A70-0B1C-4784-815D-DFC48DFD0649 Permit:NC0033685 Inspection Date:09/19/2019 Owner - Facility: Inspection Type: Mountain Glen Golf Club Compliance Evaluation Aeration Basins Yes No NA NE Is the DO level acceptable?(1.0 to 3.0 mg/l) DO measured at 6.7 mg/L, pH was 7.1, settleability was ~20% at 30 minComment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use?2 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Page#4 DocuSign Envelope ID: 65012A70-0B1C-4784-815D-DFC48DFD0649 Permit:NC0033685 Inspection Date:09/19/2019 Owner - Facility: Inspection Type: Mountain Glen Golf Club Compliance Evaluation De-chlorination Yes No NA NE Are tablet de-chlorinators operational? Number of tubes in use? There is not a dechlorinator. There is a manhole that the ORC drops dechlorination tablets into. This is an unusual way to dechlorinate effluent, but it appeared that it could be effective. Some sort of tablet dispenser would be preferred to the current set up. Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Page#5 DocuSign Envelope ID: 65012A70-0B1C-4784-815D-DFC48DFD0649