HomeMy WebLinkAbout20071673 Ver 2_Approval Letter_20090914NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins Dee Freeman
Governor Director Secretary
September 14, 2009
DWQ# 07-1673 V2
Mecklenburg County
Mr. Pete Lang
Ballantyne Holdings, LLC
111 Clebourne Street, Ste. 200
Fort Mill, SC 29715
Subject: Providence Road West, US Hwy. 521
APPROVAL of 401 Water Quality Certification with Additional Conditions
Dear Mr. Lang:
The requested extension is approved, in accordance with the attached conditions and those listed
below, to fill 0.123 acre of wetland and to impact 290 linear feet (if) of intermittent stream to Clems Branch in
order to construct the development in Mecklenburg County, as described in your application received by the
Division of Water Quality (DWQ) on October 2, 2007. After reviewing your application, we have determined
that this project is covered by Water Quality General Certification Number 3705, which can be viewed on our
web site at http://h2o.enr.state.nc.us/ncwetiands/regcert.htmi). The General Certification allows you to use
Nationwide Permit Number 39 once it is issued to you by the U.S. Army Corps of Engineers. Please note that
you should get any other federal, state or local permits before proceeding with your project, including those
required by (but not limited to) Sediment and Erosion Control, Non-Discharge, and Water Supply Watershed
regulations.
The above noted Certification will expire when the associated 404 permit expires unless otherwise
specified in the General Certification. This approval is only valid for the purpose and design that you described
in your application. If you change your project, you must notify us in writing, and you may be required to send
us a new application for a new certification. If the property is sold, the new owner must be given a copy of the
Certification and approval letter; and is thereby responsible for complying with all conditions.
In addition to the requirements of the certification, you must also comply with the following conditions:
The Mooresville Regional Office shall be notified in writing once construction at the approved impact areas
has commenced.
2. Culverts placed in streams/wetlands shall be installed "in the dry". Immediately upon completion of the
installation, water flow shall be returned to its natural course. Existing stream dimensions (including the cross
section dimensions, pattern, and longitudinal profile) must be maintained (or restored via constructed
benches) above and below locations of each culvert. If any of the existing pipes are or become perched, the
appropriate stream grade shall be re-established or, if the pipes installed in a perched manner, the pipes shall
be removed and re-installed correctly.
Mooresville Regional Office One
Location: 610 East Center Avenue, Suite 301, Mooresville, NC 28115 NorthCarolina
Phone: (704) 663-1699\Fax: (704) 663-6040\ Customer Service: 1-877-623-6748 ?atllra!!l?
Internet: www.ncwaterquality.orq
An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper
3. Use of native vegetation and other soft stream bank stabilization techniques must be used where practicable
instead of riprap or other bank hardening methods. If riprap is necessary, it shall not be placed in the
streambed, unless approved by the DWQ.
4. Storm water discharge structures at this site shall be constructed in a manner such that the potential
receiving streams (of the discharge) will not be impacted due to sediment accumulations, scouring or erosion
of the stream banks.
5. A final, written storm water management plan (including a signed and notarized Operation and
Maintenance Agreement) shall be submitted to the 401 Oversight and Express Permitting Unit (2321
Crabtree Blvd., Suite 250, Raleigh, NC, 27604 or local delegated authority) within 60 days of the issuance
of the 401 Water Quality Certification. The storm water management plan shall be approved in writing by
this Office (or local governing authority and copy provided to DWQ) before the impacts specified in this
Certification occur per Condition No. 3631 in GC No. 4. You have the option of using the Express Review
Program for expedited approval of these plans. If you propose to use the Express Review Program,
remember to include the appropriate fee with the plan. The storm water management plan must include
construction plans, specifications, storm water BMP worksheets, and supporting calculations. The storm
water best management practices are required to be appropriate for the surface water classification and
designed to remove at least 85% TSS according to the most recent version of the NC DENR Storm water
Best Management Practices Manual. These facilities must be designed to treat the runoff from the entire
project, unless otherwise explicitly approved by the Division of Water Quality. Also, before any permanent
building is occupied at the subject site, the facilities shall be constructed and operational, and the storm
water management plan (as approved by this Office or local delegated authority) shall be implemented.
The structural storm water practices as approved by this Office as well as drainage patterns must be
maintained in perpetuity. No changes to the structural storm water practices shall be made without written
authorization.
6. No waste, spoil, solids, or fill of any kind shall occur in wetlands, waters, or riparian areas beyond the
footprint of the impacts depicted in the Preconstruction Notification application. All construction activities
associated with this project shall meet, and/or exceed, those requirements specified in the most recent
version of the North Carolina Sediment and Erosion Control Manual and shall be conducted so that no
violations of state water quality standards, statutes, or rules occur.
7. Sediment and erosion control measures shall not be placed in wetlands or waters to the maximum extent
practicable. If placement of sediment and erosion control devices in wetlands and waters is unavoidable,
they shall be removed and the natural grade restored within two months of the date the Division of Land
Resources has released the project.
8. Upon completion of the project, the applicant shall complete and return the enclosed "Certificate of
Completion" form to the 401 /Wetlands Unit of the NC Division of Water Quality.
9. Continuing Compliance. The applicant (Ballantyne Holdings, LLC; Pete Lang) shall conduct all activities in a
manner so as not to contravene any state water quality standard (including any requirements for compliance
with section 303(d) of the Clean Water Act) and any other appropriate requirements of state and federal law.
If DWQ determines that such standards or laws are not being met (including the failure to sustain a
designated or achieved use) or that state or federal law is being violated, or that further conditions are
necessary to assure compliance, DWQ may reevaluate and modify this certification to include conditions
appropriate to assure compliance with such standards and requirements in accordance with 15 A NCAC
2H.0507(d). Before codifying the certification, DWQ shall notify the applicant and the US Army Corps of
Engineers, provide public notice in accordance with 15A NCAC 2H.0503, and provide opportunity for public
hearing in accordance with 15A NCAC 2H.0504. Any new or revised conditions shall be provided to the
applicant in writing, shall be provided to the United States Army Corps of Engineers for reference in any
permit issued pursuant to Section 404 of the Clean Water Act, and shall also become conditions of the 404
Permit for the project.
If you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing.
You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written
petition that conforms to Chapter 150B of the North Carolina General Statutes to the Office of Administrative
Hearings, 6714 Mail Service Center, Raleigh, N.C. 27699-6714. This certification and its conditions are final
and binding unless you ask for a hearing.
This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act.
If you have any questions, please telephone Mr. Alan Johnson in the Mooresville Regional Office at 704-663-
1699 or Ms. Cyndi Karoly in the Central Office in Raleigh 919-733-9721.
Sincerely,
for Coleen H. Sullins
cc: Army Corps of Engineers, Asheville
Ian McMillan, Wetlands Unit
Matt Bramblett, Hart/Hickman, 2923 S. Tryon, Ste. 100, Charlotte, 28203