Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG140274_COMPLETE FILE - HISTORICAL_20170801
STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT N0. /v Lh )-IC� DOC TYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ �01 I D � o � YYYYMMDD Energy, Mlnerul & Land Resources ENVIRONMENTAt OVALITY August 1, 2017 Southern Equipment Company Inc Attn: Stephen Simonsen 3015 Windward Plz Ste 300 Alpharetta, GA 30005 ROY COOPER G'ovprnar MICHAEL S. REGAN secremry TRACY DAVIS Director Subject: NPDES Stormwater Permit Coverage Renewal COC #NCG140274 Dear Permittee: For coverage under Stormwater General Permit NCG140000, the Division of Energy, Mineral, and Land Resources (DEMLR) is forwarding herewith the reissued Certificate of Coverage (COC). This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated October 15, 2007 (or as subsequently amended.) A new Certificate of Coverage (COC) is included with this letter. You must print a copy of the new NCG140000 General Permit from our website here: ,.httpTIIdeg,nc•govJabou t/di vision Jenergry-minera] -land-resources/ene ,u-mineral-land- perm its Istormwater-perm its Jnpdes--irldustria]-sw. In addition to the full permit, the 2017 print package on the website includes revised Discharge Monitoring Report (DMR) forms, Annual Discharge Monitoring Report forms, and Qualitative Monitoring Report Forms. The General Permit authorizes discharges of stormwater and wastewater (if applicable), and it specifies your obligations with respect to discharge controls, management, monitoring, and record keeping. Please review the new permit to familiarize yourself with all changes in the reissued permit. Significant changes to the General Permit are outlined in the Technical Bulletin, which is also available on the website above. Your facility has six months from receipt of the permit to update your Stormwater Pollution Prevention Plan (SPPP) to reflect any new permit requirements. !'-'Nothing Compares,---�. SState of North Carolina I Environmental Quality } Energy. Mineral and Land Resources 512 N. Salisbury Street } 1612 Mail Service Center I Raleigh. North Carolina 27699-1612 919 707 9200 et How does the new General Permit affect Tier Status? The first sample period of your permit begins August 1, 2017. Tier 3 actions in Part IV of your permit are triggered by benchmark exceedances on four occasions beginning on the effective date of this permit and do not count prior exceedances. likewise, Tier 2 actions are triggered by two consecutive benchmark exceedances beginning on the effective date of this permit and do not count prior exceedances. However, if your facility is already in Tier 2 (monitoring stormwater discharges monthly) or Tier 3, you must continue monthly monitoring until relieved through conditions of the permit or by DEMLR staff approval. When does electronic DMR reporting start? We are setting up our database with final permit parameters and the outfalls that permittees submitted on-line. All NCG14 Permittees will receive notification when our eDMR system is ready for these permittees to register and begin reporting monitoring data electronically. If you have any questions about the status, please contact Bethany Georgoulias at (919) 807-6372 or Robert Patterson at (919) 807-6369. If you did not submit outfall information already, we have included a form for you to return to us. (Note: NO FORM IS ATTACHED if we already have your outfall information.) Your coverage under the General Permit is transferable only through the specific action of DEMLR. This permit does not affect the legal requirements to obtain other permits which may be required by the N.C. Department of Environmental Quality (DEQ), nor does it relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact the DEMLR Stormwater Permitting Program at (919) 707-9220. cc: Stormwater Program files Sincerely, r6� �ksor for Tracy E. Davis, P.E., C.P.M. -5^Nothlng Cornpares._�_,... State of North CaroBna I Environmental Qualit y I Energy, Mineral and Land Rrsources 512 N, Solishury Street I t6t2 Mail Service Center l Raleigh, North Carolina 27694-1t,12 �41) 707 9200 STATE OF NORTH CAROLINA . DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL, AND LAND. RESOURCES STORMWATER AND WASTEWATER DISCHARGES In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Southern Equipment Company Inc is hereby authorized to operate approved wastewater treatment system(s) and discharge stormwater and/or wastewater, as approved in the original permit/application or subsequent permit modification, from a facility located at: Ready Mixed Concrete Company - Raeford, Plant 118 336 Hobson Rd Raeford Hoke County to receiving waters designated as Puppy Creek, class C waters in the Cape Fear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, and V of General Permit No. NCG140000 as attached. This Certificate of Coverage (COC) shall become effective August 1, 2017. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day August 1, 2017. r6y vwo# for Tracy E. Davis, P.E., CPM Director, Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission Geor oulias, Bethany From: Georgoulias, Bethany Sent: Tuesday, July OS, 2016 9:22 AM To: 'ssimonsen@argos-us.com' Subject: NPDES NCG140000 General Permit renewed on July 1 Dear Permit Contact: Thank you for submitting the permit renewal request (received on 06/29/2016-11:23am) for Permit COC No. NCG140180. The NCG140000 General Permit has been reissued with no changes for one year, effective Friday, July 1, 2016. As we stated in our letter from May 31', we will not issue you a new Certificate of Coverage until next year, when the General Permit is revised. However, the cover page of the permit has been revised to reflect new effective dates. For your records, you may print a copy of the new General Permit cover page from our website (in the NPDES Industrial SW section, General Permits). Or, you can go to this NCG14 Renewals Map and search for your permit. The "More Info" link next the General Permit field in the pop-up box has been revised with the new permit. You only need to print the cover page that reflects the new dates for your records. Please continue to use the same data monitoring forms (DMR). As a reminder, if there has been a company ownership change, or if the Owner Affiliation needs to be updated, you must submit the appropriate signed form to DEMLR's Stormwater Program. Please contact us if you need one of those forms or have any other questions. Sincerely, The Stormwater Program Bethany Georgoulias Environmental Engineer Stormwater Permitting Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethan . ,eorgoulias@ncdent-,�,,ov_ 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: http://portal.ncdenr.org/web/1r/storniwater 127 r 1� 'trr � k'� qk`b ' ��rRi '��'!' �. �V.t �' •n fi � M--Vrwj �'�_..i'�' r Mc, e r 1 r fi Amp •1 �„ 1 'r- �.tTfy ,AEI/\. � j �'1 Fes', y ' 'r . - _ � � l �fl. 'r '1'� ll�C� �' r �y �4r; �� 4.rt •.� lM f t,_4sl flr +.lt ,1 rits rk1 vill r T" .11h '�`.•��' �`1t'.'�?il..Jf�"`�t 1 �M� � r - ,fir fi �•�+� . r !v,`� y •J*...��Yd 1 .AS.. i.,ell r. J .iy,- � 1 `tip. � ^• - ** 77 e h 15 N ' .'1 4 '•M ♦'''- `r „�,���b' ! J ` 1. +si ,-f' -. �' Lam- �y r �i•'r� '�^�,. .1L� ate' ► � 4 ry � 'F�iJ. mil. � Y.r�,. �:,' ' y.. -�� f � � `�}� 'i'd `., •] i f. s Lt a IL L Permit: NCG140274 SOC: County: Hoke Region: Fayetteville Com fiance Ins action Repo Effective: 07/01/16 Expiration: 06/30/17 Owner: Southern Equipment Company Inc Effective: Expiration:. Facility: Ready Mixed Concrete Company - Raeford, Plant 11 336 Hobson Rd Contact Person: Sammy F Parker Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): On -site representative On -site representative Related Permits: Raeford NC 28376 Title: Phone: 910-875-4046 Certification: Phone: Troy Wortham 910-875-4353 Dewey Jernigan 910-483-6611 Inspection Date: 02t24I2017 Entry r'Time: 10:20AM Primary Inspector: Melissa A Joyner Secondary Inspector(s): Exit Time; 11:25AM Phone: ��ro- yes-��4-�� e-z�. 335y Reason for inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Ready Mix Concrete StormwaterNVastewater Discharge COC Facility Status: Compliant [] Not Compliant Question Areas: Storm Water (See attachment summary) Page: 1 Permit: NCG140274 Owner • Facility: southern Equipment Company Inc Inspection Date: 02/2412017 inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: Melissa Joyner met with Dewey Jernigan, Operations Manager and Troy Wortham, Plant Manager on February 24, 2017 at the facility located on 336 Hobson Road, Raeford, in Hoke county as part of a Multimedia inspection to determine compliance with Air Quality regulations and the conditions of the NPDES General Permit NCG140000. This facility is currently owned and operated by Argos Ready Mix. A Permit Name/Ownership Change Form for this facility or letter from the current owner updating ownership of all facilities in the state needs to be submitted to staff with the Stormwater Permitting Program at the Central Office in Raleigh in order to update our files. The Stormwater Pollution Prevention Plan was reviewed and contained the required components as specified in the permit. No spills have taken place at the facility since the previous inspection of the facility in October 2012. There is one outfall on the site. Since both stormwater and processed wastewater would be discharged from this outfall when the facility is operational, the outfall is monitored on a quarterly basis. The monitoring records indicated no flow/no discharge for the monitoring periods since the previous inspection of the facility. The facility has one stormwater-only outfall, therefore the annual non-stormwater discharge certification is not applicable. A tour was conducted of the facility's grounds where the outfall, secondary containment area and concrete washout pit was observed. The outfall was at a low point on the property and received sheet flow. There was no visual evidencs of recent discharge through the outfall. The facility appeared well -maintained and in compliance with the conditions of General Permit NCG140000. Page: 2 Permit: NCG140274 Owner - Facility; Southern Equipment Company Inc Inspection Date: 02t24l2017 Inspection Type: Compliance Evaluation Reason for Visit: Routine Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ M ❑ Comment: The facility does not have any outfalls requiring semi-annual visual monitoring. The single outfall receives both Processed wastewater and stormwater reguiring quarterlyvisual monitoring. Permit and Outfalls Yes No NA_ NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ 110 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ ❑ Comment: Qualitative Monitoring Yea No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ❑ ■ ❑ Comment: Stormwater Pollution Prevention Does the site have a Stormwater Pollution Prevention Plan? ❑ ❑ ❑ .# Does the Plan include a General Location (USGS) map? M ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? S ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? 0 ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? 0 ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? M Cl ❑ ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a SMP summary? 0 ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? M ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # is the Plan reviewed and updated annually? ■ ❑ ❑ ❑ # Does the Flan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ■ Cl ❑ ❑ Page: 3 Permit: NCG140274 Owner • Facility: Southern Equipment Company Inc Inspection Date: 02124/2017 Inspection Type : Compliance Evaluation .. . Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Comment: Page: 4 While most items covered were considered compliant there are items that need attention. These and other findings are listed below: -The site was found to be neat and well maintained, - Located on the site is a second ready mixed plant # 121. The second plant appears to generates wastewater and stormwater in the same manner as plant # 118. Ready Mixed Concrete Company is asked to make sure your Stormwater Pollution Prevention Plan and other required components of your permit reflect the presence of the plant # 121. Further, you are also asked to make sure that onsite BMPs are designed and operated in manner to treat the additional loading. - Considerable time was taken going over the permit. When discussing analytical and qualitative monitoring and during the site tour it became apparent that site personnel have been sampling a point that is NOT representative of the actual discharge from the site should a discharge occur. The stormwater sampling point was noted to be a point in which stormwater would pool near the rear of the property. Based on discussions with you and Mr. Underwood and based on a rather lengthily tour of the property it is unclear if the site ever actually discharges. Noted during the tour was a berm of soil and a old silt fence at the rear of the property. Also observed was a depression or old ditch that had no point of discharge. Per our discussion you should not feel compelled to sample any point that is not a true Stormwater Discharge Outfall (SDO). You should never sample anything that is not a true discharge and representative of the stormwater/process wastewater leaving the site. In keeping with our discussion it is understood that you are going to clear (mow) the rear of the property in order to properly determine the stormwater flow path(s) and where the true SDO point(s) are located. Also discussed was the possibility of determining site contours or elevations to determine the "low spot". In the event that you do not feel the site routinely or ever discharges you are asked to establish and clearly mark the point a discharge would occur. You are asked to contact the writer within 30 days of completion of the noted work to schedule a second site visit. This second visit will be, at a minimum, for the verification of SDOs should they exist. Discharge Monitoring Reports. As noted above please do not feel compelled to sample if your site(s) do not discharge. Please refer to Section E: Reporting Requirements, item 1 of your permit. The permit states, in part "When no discharge has occurred from the facility during the report period, the permittee is required to submit a discharge monitoring report, within 30 days of the end of the sampling period, giving all required information and indicating "NO FLOW" as per 15A NCAC 028 .0506." please in the future submit the required discharge monitoring report with "NO FLOW " indicated if called for. Further, make sure that qualitative monitoring is conducted as required. - Flow from parking area appeared to sheet flow to the area noted above at the rear of the property. - All records were available and organized, - Employee training includes videos, class discussion of environmental and safety related items. - No spills recorded, - Secondary containment was observed to have the appropriate locking device on the discharge point, - Mr. Underwood was encouraged to review the permit as often as necessary to be aware of the terms and conditions contained in the document, - You can refer to the DWQStormwater Permitting Unit web site for further information and forms, http://portal.ncdenr.org/web/wq/ws/su/npdessw ��A NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Division of Water Quality Charles Wakild, P. E. Director November 1, 2012 Dewey Jernigan, Production Manager Ready Mixed Concrete Company 427 Franklin Street Fayetteville, N.C. 28301 Dee Freeman Secretary Subject: Follow-up Site Visit Ready Mixed Concrete Company - Plant 118 . NPDES Stormwater General Permit No. NCG140000, COC No. NCG140274 Hoke County Dear Mr. Jernigan: This letter is to relay the findings of a follow-up site visit to the Ready Mixed Concrete Company - Plant 118 located at 336 Hobson Road, Raeford -North Carolina October 31, 2012. The follow-up visit was to observe site clearing (mowing) that had been performed at the rear of the property to determine the exact location of the stormwater discharge outfall (SDO). Based on your comments and the site visit it was determined that there is only one SDO for the site. Further, it is believed that the site will only discharge during extreme weather events and/or during periods of extended wet weather. You are urged to keep the vegetation at this location managed in such a manner that observations of the SDO can be performed easily and safely. Also please take samples of stormwater discharges only as outlined in your permit and submit the data as required. As discussed, if the site does not discharge please follow the instructions for "No Flow" discharge reports set forth in your permit. Location: 225 Green Street, Suite 714, Fayetteville, North Carolina 28301-5043 Phone: 910-433-33001 FAX: 910.486.07071 Customer Service: 1-877.623.6748 Internel: www.ncwaterguality.orQ An EgUal Opportunity l Affirmative Action Employer One NorthCarolina Natma!!y Mr. Jernigan November 1, 2012 Page 2 of' 2 If you have questions or comments related to this matter please do not hesitate to contact me at (910) 433-3303. Sincerely, Paul E. Rawls Environmental Program Consultant PER/pr cc: Duane Allen, Ready Mixed Concrete Company FRO-SWPS NORTH CAROLINA DIVISION OF AIR QUALITY Inspection Report Date: 10/27/2015 Facility Data Ready Mixed Concrete - Raeford Plant 118 336 Hobson Road Raeford, NC 28390 Lat: 35d 1.8460m Long: 79d 8.6010m SIC: 3273 / Ready -Mixed Concrete NAICS: 32732 / Ready -Mix Concrete Manufacturing Facility Contact Ronnie Butner Plant Manager (910)875-4353 Comments: Inspector's Signature: Date of Signature: Contact Data Authorized Contact Duane Allen Division Manager (910) 483-5511 Fayetteville Regional Office Ready Mixed Concrete - Raeford Plant 118 NC Facility ID 4700026 County/FiPS: Hoke/093 Permit Data Permit 07418 / R14 Issued 1/14/2014 Expires 12/31/2021 Classification Small Permit Status Active Current Permit Application(s) None Technical Contact I SIP Dewey Jernigan Operations Manager (910) 483-5511 Program Applicability Compliance Data Inspection Date 10/21/2015 Inspector's Name Mitch Revels Operating Status Operating Compliance Code Compliance - inspection Action Code FCE On -Site Inspection Result Compliance N Total Actual emissions in TONS/YEAR: N TSP SO2 NOX VOC CO PMIO * HAP 2012 0.2450 --- --- --- --- 0.1190 0.0001 2008 0.2040 --- --- --- --- 0.0810 --- Five Year Violation History: None Date Letter Type Rule Violated Performed Stack Tests since last FCE: None Date Test Results Test Method(s) * Highest HAP Emitted (in Violation Resolution Date Source(s) Tested 1) NESHAP APPLICABILITY: The facility did not have a process hot water heater or boiler. The facility did not have an emergency generator or other engine that would be subject to GACT 4Z. of 2) Directions: From FRO travel about 10 miles on Business Hwy 401 South/Raeford Rd; about 3.5 miles after entering Hoke County, turn right onto Hobson Road; travel about 0.2 miles; facility is on the right. 3) Safety Equipment: Standard DAQ FRO safety gear. Be aware of moving equipment and overhead conveyors when operating. 4) Process/Facility Description: Concrete is composed essentially of water, cement, fly ash, and aggregate (fine/coarse). Fly ash used as a specialty aggregate. The plant stores, conveys, measures and discharge these constituents into a truck for mixing and transport to the job site. A dump pit is used to transfer sand and rock to one of three storage silos via an open belt system. The sand and rock is then transferred to the three -bin hopper via an open belt system. Sand and aggregate is then weighted for use by the weigh -hopper under the three -bin hopper. The material is then transferred to the mixing hopper via a conveyor belt and is mixed with water, cement and sometimes fly ash. The fly ash is conveyed to the mix hopper via a closed augur which is later dropped into the truck. 5) Permitted Sources: 1~missian Control n Source Control System SourceIl System r=D—ele1ptianfD Description „: , .. Concrete Batch°Planf't='3ficu�bic''ya ds�per hour,maximum capacity Truck Mix Operation: 36 cyds/hr TM I Not observed operating. CD I One (1) Bagfilter 1433 5q. Ft Filter Area Not operated during 2015 Weigh hopper (7,000 lb capacity) Will Not observed operating Cement silo (52 ton capacity) [CS1 Not observed operating. CS2 Cement silo (100 ton capacity) Not observed operating. ne ( l) Fly ash silo (52 ton capacity) AS I rNot F observed operating. Cancretc`Hatch Plant 2 96 cubic yards"per�hbur maalmume,capaclty — _ TM 2 Truck Mix Operation: 96 cyds/hr CD 2 One (1) Bagfilter (1060 square feet of filter area) Not observed operating Not observed operating. WI i 2 Weigh Hopper 10,000 lb. capacity CF 4 One (1) Cartridge Filter (20 square feet of filter area) Not observed operating Not observed operating. CS 3 Cernent Silo 99 Ton Capacity yBF 3 One (1) Bagfilter (225 square feet of filter area) Nol observed operating Not observed operating. rS_2_ Flyash Silo 97 Ton Capacity BI 4 One (1) Bagfilter (225 square feet of filter area) Not observed operating, Not observed operating 6) Insianificant/Exempt Sources: Source aP Saurce aP TgAPs? 090611 itle V utanta? I-SAGH-1 Sand & Aggregate handling system for Plant I ir 2Q .0102 (c)(2)(E)(i) No ! Yes Sand & A e atelH ndl n 2S stem for Plant 2 2Q 0102 (c)(2)(E){i} No Yes — P� $_._ ...--g--y— ----- —. _i .......... __....... _ _ ....... - - 7) Opening Conference: On 21 October 2015, I, Mitchell Revels with DAQ FRO met with Ronnie Butner, Plant Manager and Kevin Honecker. Mr. Honecker said that he is the plant manager for the facility located in Spring Lake and that he was at this plant only to assist the new plant manager, Ronnie Butner. He also said that Mr. Dennis Underwood was moved to the plant in Laurinburg. I explained the permit conditions and what is expected during the compliance inspection. Mr. Honecker provided the I/M logbook that contained the air permit and the bagfilter maintenance records along with production records. It seemed that Mr. Butner was not as knowledgeable as Mr. Honecker concerning the permit and records required by the permit. Mr. Honecker indicated that he would be working with Mr. Butner to get him up to speed with the air permit requirements. Mr. Honecker reviewed the FACFINDER and indicated that all was correct with exception to Mr. Underwood replaced with Mr. Butner. My review of the log indicated an annual inspection occurred on 8 July 2015 by the contractors Filter Kleen Environmental Service for both plants. The log also indicated daily general inspections are done by Ronnie Butner. Mr. Butner stated that Plant #2 was presently not needed and Plant # 1 will produced about 9,500 cubic yards for cy 2015. 8) Walk Through: Mr. Honecker and I went outside to walk the surrounding grounds. A truck was loaded with concrete to be delivered and no dust appeared. The plant appeared to be well maintained and operated. According to records, this facility produces a relatively small amount of concrete annually, around 9500 cubic yard. The permit concrete production limit for NC Toxic, 15A NCAC 2D.1100 is 105,000 cubic yards. 9) Throup-hnuts• Employees 3 employees Hours of Operation Mon - Fri; lam to 5 m; Customer demands. Production 9,500 cu yds. For cy 2015 10) Stipulations: A.2 PERMIT RENEWAL AND EMISSION INVENTORY REQUIREMENT - entire facility subject. Permit renewal request and emission inventory due at least 90 days prior to permit expiration date. Appears in Compliance -- submitted the previous permit renewal application and CY 2012 El on time, next inventory not due until Sept 2021. A.3 2D .0515 PARTICULATE CONTROL REQUIREMENT_ - particulate matter emissions from the emission sources shall not exceed allowable emission rates. Appeared in Compliance - Compliance was determined during the most recent permit review based on how the source was operated at the time. No changes have been made to operations since that determination." AA 2D .0521 VISIBLE EMISSIONS CONTROL REQUIREMENT - Visible emissions from the facility, manufactured after 1 July 1971 shall not exceed 20% opacity. Appears in Compliance —No VE was observed, not operating. The facility was loading cement during the previous inspection by Pam Vivian on 2014 Nov 21 and she stated no VE was observed. A.5 2D .0535, "Notification Requirement" — subject sources are entire facility. Requires notification of excess emissions that lasts more than 4 hours. Appeared in Compliance - Mr. Honecker stated that to the best of his knowledge, this facility has not had any excess emissions that exceeded limits for more than four. A.6 2D .0540 FUGITIVE NON -PROCESS DUST EMISSIONS —The Permittee shall not allow fugitive non -process dust emissions to contribute to substantive complaints. Appears in Compliance — The facility does use water suppression to help control dust emissions on the grounds. I did not observe excessive fugitive dust or any fugitive dust leaving the property. No dust complaint have been received by DAQ during the past year. A.7 2D .0611 FABRIC FILTER REQUIREMENTS — The Permittee shall record bag filter inspections and maintenance in a logbook. Appears in Compliance — The I/M logbook indicates contractors Filter Kleen Services performed an annual compliance inspection on all control devices on 8 July 2015 and daily checks are done by plant personnel. UM records indicate that cartridge filters are routinely changed during the annual inspection. A.8 215.1100 TOXIC AIR POLLUTANT CONTROL REQUIREMENTS — Arsenic facility wide limt: 0.05063 Ib/yr - The maximum concrete production is a function of the distance to the closest property line; for this facility the distance is 154 feet and the maximum annual production can be 105,000 yards. The Permittee shall record concrete production each month and total annually. Maximum hourly throughput must not exceed 138 cubic yards per hour. The Permittee shall submit an annual report by I March of each year. Appears in Compliance — The closest property line to the mixer is staked and was determined using a range finder to be 162 ft, which is consistent with the required distance for this facility . The 2014 yearly annual report was received on time; 2014 concrete production was about 9500 cubic yards per year. The permit production is 105,000 cubic yards and the facility has produced around 9,500 cubic yards annually for the past several years. 11) Non- (:ompliance History Since 2010: This facility has no non-compliance history since 2010. 12) 112r Status: This facility neither uses nor stores chemical compounds that require a written risk management plan under the Clean Air Act, Section 112R. 13) Comment/Recommendation: The facility appears to be well -maintained and operated. It appeared to be operating in compliance as of this inspection. Pink Sheet Items; None at this time. /mr FILTER KLEEN ENVIRONMENTAL --)tVIC E� 1304 Meredith Park Drive DATE McDonough, GA30253 (678) 435-0601 OMERRAME rqos ADDRESS y \J CI)r11 e ol IN d SW COUNTY CUSTOMER NUMBER ACCOUNT NUMBER PO NUMBEfl MA6S IRIAL NO. SIZE SE DESCRIPTIqN PROBLEM WITH -s- WORK REQUIRED TO REPAIR Si '6'4."j" ce Z..' if pi'l if c �"Q f A k�, d'c'�a, 4 c (fl-rtl ktv aoo, k,"q, el f, -...cr- 0 CL4,11 tall r.( fi 4v rtd L - t' yl ril U 2--1 1 PNe cia, (,-A CL-V' -4 p've-1 -Aa-?hL -k- I f Icz- 64 WORK ORDER NO.'dfla4 PARTS ORDER QUAN NUMBER DESCRIPTION PRICE EACH 1 1C.8-4- O.'a -4 - /A� I C-�V �-41 q-./ HRS HOUR LABOR TOTAL PARTS AND MATERIALS DATE I MEN START FINISH WORKED RATE TOTAL I*f SALESTAX REGULAR J40URS L4 TOTAL LABOR HRS REG. LABOR OVERTIME HOURS TOTALLABOR HRS OT TOTALEXPENSES MILES x RATE CUSTOMERACCEPTANCE OF DESIRED WORK TRAVEL HOURS X; RATE SERVICE MAN Ai —7 TOTAL AMOUNT L SERVICE POLICY TRAVEL TIME LABOR RATES APPLY FROM SHOP TO JOB. MILAGE CHARGED TO ALL POINTS, ATLANTA INCLUDED. EXPENSES; HOTEL, MEALS, COMMON CARRIER AND/OR TRUCK MILAGE FROM OUR SHOP AND,RE-bURN. WARRANTIES; EQUIPMENT WARRANTIES COVER PARTS ONLY- F-0.13. FACTORIES LABOR EXPENSES AND FREIGHT NOT COVERED. FILTER KID EN, INC. Environmental Service 1304 Meredith Park Drive McDonough, GA 30253 (678) 435-0601 DUST COLLECTION / BAG HOUSE MAINTENANCE INSPECTION Inspection Date: t- Performed by: 'W r , t 41.1 ITEM Housing Exterior Door and Door Gasket Shaker Drive Mechanism & Motor Belts Bearings Shaft Bag Straps Filter Bags :omments: R CONDITION k © Excellent 1 'M Excellent © Excellent ❑ Excellent • Excellent • Excellent C3 Excellent 7 Excellent �V Fair n Fair E �© Fair CI Fair 4 Fair Fair -63 Fair a E1 Fair Company: AA s r I 3 Plant:fC q ER PaIRs Ti NATURE © Poor O Poor • Poor © Poor 0 Poor # Bags Replaced COMPLETION DATE DAQ - Toolbox - FacFinder Page 1 of 1 Air Quality v I Toolbox v FacFinder Welcome to Facility Print Melp Logoff Finder Find Facility Compliance Data Assigned Inspector: Pam Vivian Facility Data Operating Status: Operating Ready Mixed Concrete - Raeford Plant 118 Compliance Status: Compliance - inspection 336 Hobson Road (oZ3q Inspection Date: 16/21/2015 Raeford, NC 28390 Inspected By: Mitch Revels County: Hoke Lat: 35d 1.8460m Long: 79d Action Code: FCE 8.6010m NC Facility ID: 4700026 Permit Data SIC: 3273/ Ready -Mixed Concrete Permit n/a NAICS: 32732 / Ready -Mix Concrete Issued n/a anufacturing Expires n/a Classification Permit Exempt Permit Status Inactive Authorized Contact Data Invoice Contact Data 4>Z3 4 Duane Allen, Division Manager Ready Mix Concrete - Raeford Plant 118 42 Box Franklin 427 Franklin Street Franny Gerald, Administrative Assistant Fayetteville, NC 28302 PO Box 470 (910) 483-5511 Fayetteville, NC 28302 (910) 483-5511 n t 1 G,l Os - us. cur✓] J���� � f a rmcc.com �.G e{ S- q6 . e em Facility Contact Data Technical Contact Data P.mmtrBMTreT, Plant Manager _ , Plant Manager 336 Hobson Road ' V 336 Hobson Road Raeford, NC 28390 Fol I/l OPr ` N Raeford, NC 28390 Tom{ WoA'1' afn (910) 875-4353 (910) 875-4353 r 14harrtG�rcjcS r m Active Programs: SIP Pending Reports: Pending Source Tests: https:Hibeamaq.nedenr.org/aq/Toolbox/FacFinder.jsp?lockey=L984LO7418 2/23/2017 Compilance Assurance Visit Checklist rev. 6/16/16 Facility Name: Physical Site Address: City: Zip Code: County: Facility Contact: Title: Phone No.: Mailing Address: Facility Contact Email Address: Is the facility contact the person that you met? If not, fill out the following: Contact Name: Title: Phone No.: Mailing Address: Email Address: Safety requirements: safety shoes (yes/no) - safety glasses (yes/no) - hearing protection (yes/no) - hardhat (yes/no) other (please describe): Normal operating schedule (hr/d, d/wk, wk/yr): a4II P. (; 41 Opacity (%) - indicate any non -zero opacities observed: Odors - indicate if any objectionable odors were detected beyond the property boundary: Fugitive dust - indicate whether fugitive dust was observed leaving property boundary: Since last inspection, have there been any changes in equipment or operation? Throughput and/or fuel usage with units: Control device(s) (list): Properly operated and maintained? - - Notes or calculation space: f Permit Exemption: • Actual emissions from the previous year(s) (and projected actual) of PM10, S02, NOx, VOCs, CO, HAPs, and TAPS are each < 5 tpy and whose actual total aggregate of these emissions are < 10 tpy • Can be subject to 40 CFR Part 63 (MACT or GACT) and 40 CFR Part 60 (NSPS) • Cannot be subject to Rule 2Q .0315 (Synthetic Minor Facilities) or 2Q .0500 (Title V Procedures) Re ism tration: • Actual aggregate emissions >= 5 tpy and < 25 tpy: PM10, CO, NOx, S02, VOCs, HAPS, and TAPS. • Cannot meet permit exemption under 2Q ,0102(d) • Cannot be subject to Rule 2Q .0315 (Synthetic Minor Facilities) or 2Q .0500 (Title V Procedures) • Cannot be subject to 40 CFR Part 63 (MACT)- {Can be subject to 40 CFR Part 63 (GACT)) • Cannot emit volatile organic compounds or nitrogen oxides if the facility is located in a nonattainment area • Cannot be subject to 40 CFR Part 60 (NSPS) except for sources which are exempt under 2Q .0102 (g) or (h) Boilers: ID No. #1 #2 #3 #4 Installed or last modified date Size (mmBTU heat input) Primary/backup fuel: Fuel used (annual) NSPS Subpart Dr, subject? 'NSPS Subpart Dc boiler if >10 mmBtu/hr and <100 mmBtu/hr installed or modified after June 9, 1989. Gas only Dc subject boilers: have they submitted initial notification (only requirement)? Yes / No / NA Gas/fuel oil Dc subject boilers: records kept of each fuel type and startup notification for each fuel? Yes / No / NA Fuel oil certification required for Dc subject boilers (0.5% max S content). Are copies kept? Yes / No / NA If fuel oil Dc subject boiler > 30 mmBtu/hr, was opacity testing performed on schedule based on results?` Yes / No / NA `If VE=O% then done annually, <=5% done semiannually, <=10% done quarterly, >10% done every 45 days, GACT 61 Gas Curtailment option claimed? Yes / No if no, has a one-time energy assessment been performed. Yes / No / NA If no, are tune-ups being done biennially (25 months since last tune-up)? Yes / No / NA If yes, are records kept for natural gas curtailment and testing less than 48 hours per year. Yes / No / NA Generators: ID No. #1 #2 #3 #4 Engine type: emergency, peak shaving, or non-emergency/process related-3 Size (hp and kW) Fuel type Manufacture date Constructed (ordered) date NSPS 41, 41, or NESHAP 4Z subject? NSPS 41, 4J, or NESHAP 4Z req met? if spark engine gas -only units indicate 4SRB, 4SLB, 25RB, or 2SLB. Control Device if non -emergency Fuel oil cert (<15 pprn S) copies kept? Hour meter reading: 41 subject if Cl engine constructed (ordered) after 7/11/05 and manufactured after 4/1/06. 4J subject if SI engine constructed (ordered) after 6/12/06 and manufactured after 4/1/06. 4Z: exi-_sting constructed before 6/12/06 or new constructed on or after 6/12/06 (compliance shown with 41, or 4J compliance). Emergency: <100 hr/yr non -emergency use allowed. No notifications required. Maintenance req: change oil/filter and inspect hoses/belts every 500 hrs/annually & air cleaner every 1000 hrs/ann; gas units inspect spark plugs every 1000 hrs/ann. Non -emergency: performance test, operating limitations, notifications, semiannual compliance reports, and maintenance: Is unit used for demand response? If so, cannot be considered emergency use after 5/1/16. Notes or calculations ace: Concrete Batch Plant: Actual annual production (cy/yr): Truck mix or Central mix plant?: Annual production (tpy): Central Mix (circle one) Controls? aghouse / Cyclone / None Crushers: How many? Wet suppression? Primary Y / N Secondary Y / N Tertiary Y / N Screens: Y / N Conveyer transfer pts: Y / N Is facility NSPS Subpart 000 subject (manufactured after 8/31/83). Yes / No / NA If subject, must have site map, updated equipment list with throughputs, and initial PM/opacity testing. Yes/No/NA Asphalt an Type (Drum or Batch): Annual production (tpy): Fuel type: Fabric filter (y or n) Dryer rating (mmBtu/hr): RAP Crushing onsite? If yes, lump buster or crusher AC heater rating (mmBtu/hr) Date constructed or modified: If after June 11, 1973 then subject to NSPS Subpart I and Methods 5 and 9 testing required. If applicable, test date: PER WE: Indicate throughput (in tpy) for each: Process: tpY Process: Unloading: Bin loading: General (dump end) load out (Shipping): Railcar hopper bottom dump pit Truck Truck hopper bottom dump pit Rail Cleaning: Hammermill: Drying: Cyclone Column Baghouse Rack Pellet Coolers: Internal operations: Cyclone - std eff. (belts, grain cleaner, head house, Cyclone - high eff. closed -loop system -w/o grain clean) NESHAP Subpart 7D subject if operate a prepared feeds manufacturing facility that uses a material containing Cr or Mn. If subject, how is compliance demonstrated? _ oo wor ing: % each must total 100 Wood waste (tpy): Planing or Sawing / chipping Throughput (board ft/yr): Rough sawing Wet / dry wood? Fine sawing Bagfilter or cyclone? Milling (& hog) Molding Sanding Wood Kiln: Throughput (board ft/yr): Hardwood: Softwood: For softwood, circle one kiln type: steam heated, direct -fired suspension, or direct -fired kiln gasifier. of W A rfF9 o -r Mr. Ricky Holloman Ready Mixed Concrete Company PO Box 470 Fayetteville, NC 28302 Dear Mr. Holloman: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality June 29, 2007 Subject: NPDES General Permit NCG140000 Certificate of Coverage NCG140274 Ready Mixed Concrete Company Formerly Metro Products & Construction Hoke County Division personnel have reviewed and approved your request to transfer coverage under the General Permit, received on March 19, 2007. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. . .If you have any questions, please contact the Stormwater Permitting Unit at (919) 733-5083, extension 502. Sincerely, ORIGINAL SIGNED BY KEN PICKLE Coleen H. Sullins cc: DWQ Central Files Fayetteville Regional Office, Water Quality Section Stormwater Permitting Unit 0 0}, Caro Ina atura!y North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service Internet: h2o.enr.state.mus 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-2496 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recyded110% Post Consumer Paper . . -; DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140274 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, 111163W'INT10,4:100832[81.71:1110041i•I0112V1 is hereby authorized to discharge stormwater from a facility located at READY MIXED CONCRETE COMPANY -PLANT 118 336 HOBSON ROAD RAEFORD HOKE COUNTY to receiving waters designated as Puppy Creek, a class C Stream, in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, and VI of General Permit No. NCG 140000 as attached. This certificate of coverage shall become effective June 29, 2007. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day June 29, 2007, ORIGINAL SIGNED BY KEN PICKLE, Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director Mr. Sammy F. Parker Metro Products & Construction 393 Rankin Street Fayetteville, North Carolina 28302 Dear Mr. Parker: NCDENR October 8, 1999 Subject: General Permit No. NCG140000 Metro Products & Construction COC NCG 140274 Hoke County In accordance with your application for discharge permit received on August 18, 1999, we are forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. The stormwater permit you are receiving, NCG140000, does not permit wasting concrete, dumping excess concrete, directly into storm sewer outfalls or into waters of the state. Any facility which either dumps excess concrete or washes excess concrete into storm sewers or waters of the state will be operating in direct violation to both the terms of this permit and the North Carolina General Statutes. Such a discharge shall be considered an illegal discharge and may subject the owner to enforcement actions in accordance with North Carolina General Statutes 143-215.6A If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this certificate of coverage shall be final and binding. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Darren England at telephone number 919/733-5083 ext. 545. Sincerely, ORIGINAL SIGNED BY WILLIAM C. Kerr T. Stevens cc: Fayetteville Regional Office 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper ��111:M II�[�7 �1►C�T:71 �1 [�1:1.��7 �l 1►�:1 DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG:140000 CERTIFICATE OF COVERAGE No. NCG140274 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Metro Products & Construction is hereby authorized to discharge stormwater from a facility located at Metro Products & Construction 336 Hobson Road Raeford, NC Hoke County to receiving waters designated as PuppyCreek, a class C stream, in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Permit No. NCG 140000 as attached. This Certificate of Coverage shall become effective October 8, 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day October 8, 1999. ORIGINAL SIGNED BY Y&LIAM C. MILLS Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Facility Location Map USGS Topographic Map 7.5 Minute Series Facility: Metro Products and Construction, Inc. Map ID: G22SW Latitude: 350 01' 45" Longitude: 790 OS' 35" FACILITY Metro Products and Construction, Inc. COUNTY Hoke NPDES NCG140274 MAP # G22SW DSN FLOW NIA SUB BASIN 03 06 15 LATITUDE 350 01' 45" LONGITUDE 790 08' 35" RECEIVING STREAM Puppy Creek STREAM CLASS C DISCHARGE CLASS Stormwater EXPIRATION DATE 07/31/04 State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director I 0WA T •• NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOUROEs July 26, 1999 SAMMY PARKER METRO PRODUCTS & CONSTRUCTION - HOKE P.Q. BOX 442 FAYETTEVILLE, BC 28302 - Subject: Reissue - NPDES Stormwater Permit Metro Products & Construction - Hoke COC Number NCG140181 _ Dear Permittee: Hoke County In response to your renewal application for continued coverage under general permit NCG140000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: * A copy of general stormwater permit NCG140000 * A Stormwater Pollution Prevention Plan (SPPP) Certification Form. Completion of this form is required to certify that you have developed and implemented the SPPP as per the conditions of the permit. This form must be completed and returned to the Division within 30 days of receipt of this letter. DO NOT SEND the SPPP with the signed form. * Five copies of the Analytical Monitoring form and five copies of the Qualitative Monitoring form * A copy of a Technical Bulletin for the general permit which outlines changes in the permit, key requirements, and addresses frequently asked questions • A Certificate of Coverage Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Aisha Lau of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 578 Sincerely, for Kerr T. Stevens cc: Central Files Stormwater any' --enerai permits Unit Files Fayetteville Regional Office 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140181 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, METRO PRODUCTS & CONSTRUCTION - HOKE is hereby authorized to operate a process wastewater treatment system, and is hereby authorized to discharge process wastewater and stormwater from a facility located at METRO PRODUCTS & CONSTRUCTION - HOKE HWY 401 BUS RAEFORD HOKE COUNTY to receiving waters designated as Peddlers Branch in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, and VI of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective August 1, 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day July 26, 1999. for Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Sammy Parker Metro Products & Construction P.O. Box 442 Fayetteville, NC 28302 Dear Sammy Parker: March 10,1995 I LTI.RXA T 0. W �EHNR OCEI%) Subject: General Permit No. NCG140000 MAR 20 199S Metro Products & Construction COC NCO140181 ' L'Ny:. MANAGEMENT Hoke County . IIOWETf VILLE AEG, OFFICE In accordance with your application for a stormwater discharge permit received on January 2, 1995, we are forwarding herewith the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. The stormwater permit you are receiving, NCG140000, does not permit wasting concrete, dumping excess concrete, directly into storm sewer outfalls or into waters of the state. Any facility which either dumps excess concrete or washes excess concrete into storm sewers or waters of the state will be operating in direct violation to both the terms of this permit and the North Carolina General Statutes. Such a discharge shall be considered an illegal discharge and may subject the owner to enforcement actions in accordance with North Carolina General Statutes 143-215.6A If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings Post Office Drawer 27447, Raleigh, North Carolina 27611-7447. Unless such demand is made, this decision shall be final and binding. Please take notice that this certificate of coverage is not transferable. Part H, B.2, addresses the requirements to be followed in case of change in ownership or control of this discharge. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any question concerning this permit, please contact MS. AISHA LAU at telephone number 9191 733-5083, extension 578. Sincerely, Original Signed By Coleen H. Sullins A. Preston Howard, Jr. P.E. cc: Fayetteville Regional Office Mr. Roosevelt Childress, EPA P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 , An Equal Opportunity Affirmative Action Employer 50% recycled110% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT STORMWATER DISCHARGES In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Metro Products & Construction, Inc. is hereby authorized to discharge stormwater from a facility located at Metro Products & Construction, Inc. Hwy. 401 Bus. Raeford Hoke County to receiving waters designated as Pedd4n Branch in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Permit No. NCG140000 as attached. This Certificate of Coverage shall become effective March 10, 1995. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day March 10, 1995. Original Signed By Coleen H. Sullins A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission K jil Ct`lit tlBc k p ., Y, i i \ I. i •� _ �' \fit r'�•+ .•. •. •• Z F 1 \ �• % \�! - �� err - s 1 'I tA:4 •��'•A\ �4 Town ib • •I �^^' � � � I �,/' - �E=F=a- a �_ is _ It � � k, � I �� �aa^'�� i ��� •, ���\ \ Tom• Q ! � � `� 1•,' \I !t!''��\\ • � c� tr ": f \fir, 1 f£ f/l a � �� � 'ter '�" — •+I� — +� / j l %- I���_� j �• �� . Elu' � ✓ ` � , t�,/ � -�� pnng 14 03 \\ 1 I '• may¢ \ l \ 1\ d ,.a � f ��� ' i''^' sfl V � I 115 � �\ N� �.. we I` „' . 1 _ \ 1� �..� �''� � � .• a ,� � •_� n � � 9158 . • I f II .-� High 'd A —�► — i 1 Ins ,.'�.� 1.� _ 4 _ wt- 'W--+�►. .\ fl•1 238 sm .ate ��\♦ tt � — 1 +r _ ter--T �'. �' —�Ir. •` . 1 � � � \ �1 1 y • 1l If. 1,Shady Grove 1 ", >a6 Yli? f —� f_1 � 6 1�\.ate Tp�kout.,,er; f� �----� '• 1 E�IJ If / T x\ \ / � ,• �3 a 11 �\ 1 _71 \ -ass a • '•G 1p 4�� 1.,11, �Fr� �-a 1�1 '�. ` � • 1 /`\ ` l w�.- rw 11\ � \\\1, �:a "�_ • y �', \ w f � ^\\mow-� `l r __ _ /- i \��J \ - y}\. // j �, 1455 14 34 _ _ _