Loading...
HomeMy WebLinkAboutNCG080845_COMPLETE FILE - HISTORICAL_20170313STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. Iv C,& O� b S y`-I' DOC TYPE I L, HISTORICAL FILE 0 MONITORING REPORTS DOC DATE p cyU 1 7 V 3 ) 3 YYYYMMDD Georgoulias, Bethany From: Georgoulias, Bethany Sent: Monday, March 13, 2017 10:50 AM To: 'Stacey Smith' Subject: RE: Durham Campus Update Letter Attachments: NCG080845_Waste-Industries-TSS_DEM LR-Response.pdf Stacey, Please see our response letter to Waste Industries LLC — Durham attached. It was signed on Friday and is being mailed out today. I meant to include you on the CC list but forgot to do so — my apologies. Best regards, Bethany Bethany Georgoulias Environmental Engineer Stormwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethanv.geor,oulias@ncdenr.gov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: http://deg.ne.gov/about/divisions/energy-mineral-land-resources/stot-mwater ' nothing Compares,, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Stacey Smith[mailto:stacey@smithgardnerinc.com] Sent: Wednesday, March 01, 2017 1:41 PM To: Georgoulias, Bethany<bethany.georgoulias@ncdenr.gov> Subject: RE: Durham Campus Update Letter Bethany, Thank you. Yes, please address the letter to John Pfleger. Sounds like you are having another wonderful transition this year. I would also like you to cc: Bill Davidson at the site address, David Pepper at the same address as John Pfleger, as well please copy me. sas Stacey A. Smith, P.E. President, Senior Engineer SMITH + GARDNER 14 N. Boylan Avenue Raleigh, North Carolina 27603 Ph: (919) 828-0577 ext. 127 M: (919) 815-0803 www.smithgardnerinc.com From: Georgoulias, Bethany[mailto:bethanv.aeorgoulias@ncdenr.gov] Sent: Wednesday, March 1, 2017 12:23 PM To: Stacey Smith Subject: RE: Durham Campus Update Letter Stacey, I'm working on a response letter from our office regarding this request. I wanted to verify the contact information for the permittee so I can address the letter appropriately. Please see attached — is the letter best addressed to John Pfleger or Ralph Ford, or another individual? Also, my supervisor retired yesterday, and we have not just a smaller set of staff, but we also have no immediate supervisor. I'm doing my best to get a response completed and signed by my section manager as soon as possible, but we will be juggling a lot of issues in the interim. Please check in if you don't hear from me by mid -March. Regards, Bethany Bethany Georgoulias Environmental Engineer Stormwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of I nvironmental Quality 919 807 6372 office bethany geor god uliasnncdenr.gov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: http://deq.ne^golabout/divisions/enemy-mineral-land-resources/stormwater t Nothing Comparesti._ Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Georgoulias, Bethany From: Georgoulias, Bethany Sent: Monday, March 13, 2017 10:47 AM To: 'Azarelo, James' Subject: RE: Waste Industries LLC - Durham Attachments: NCG080845_Waste-Industries-TSS_DEM LR- Response. pdf Jim, I'm attaching your copy of our response letter. Please let us know if you have any questions. Best regards, Bethany Bethany Georgoulias Environmental Engineer Stormwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethany geor =oL ulias()ncdcnr.gov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: htt ://de .nc..ov/about/divisions/ener 7 -mineral-land-resources/storrnwater s 1' Nothing Compares,-, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Azarelo, James [mailto:James.Azarelo@durhamnc.gov] Sent: Monday, March 13, 2017 9:49 AM To: Georgoulias, Bethany <bethany.georgoulias@ncdenr.gov> Subject: RE: Waste Industries LLC - Durham Any time, Bethany. We're happy to help out. Jim From: Georgoulias, Bethany [mailto:bethanygeorgouliasna ncdenr.gov] Sent: Friday, March 10, 2017 1:48 PM To: Azarelo, James Subject: RE: Waste Industries LLC - Durham Thanks so much for the information and your feedback, Jim. I will be sure to copy you on the final letter when it goes out to the permittee. Best regards, Bethany Bethany Georgoulias Environmental Engineer Stormwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethanYgeor,,oL, uliast,nedenr.gov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website:littp:Hdcq.nc.gQv/about/divisions/enemy-mineral-land-resources/stonnwater Fc. �/' 'Noticing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Azarelo, James[mailto:James.Azarelo@durhamnc.gov] Sent: Thursday, March 09, 2017 3:06 PM To: Georgoulias, Bethany<bethany.georgoulias@ncdenr.gov> Subject: RE: Waste Industries LLC - Durham Bethany, Based on our observations and data, we have no objection to your decision to alter the Waste Industries monitoring plan. We concur with your assessment that Waste Industries has made a good faith effort at maintaining best management practices to control sediment discharge from their site. Also, my experience inspecting the site in -person confirms your GIS observation of a long distance between the facility discharge and surface waters. Our closest stream monitoring site is located approximately four miles downstream of Waste Industries. Attached, please find a report of our monitoring results prepared by City of Durham Water Quality Specialist Susan Gale. Susan reaches a similar conclusion that, while there are some elevated TSS and turbidity values observed, the distance between the monitoring site and Waste Industries makes it unlikely that the facility is contributing to the sediment load. Feel free to contact us if you need further assistance. Thanks, Jim Azarelo Energy, Mineral & Land Resources ENVIRONMENTAL DUALtTV March 10, 2017 Mr, John Pfleger Waste Industries, LLC-Durham 3301 Benson Drive, Suite 601 Raleigh, North Carolina 27609 ROY COOPER Governor MICHAEL S. REGAN Secretary TRACY DAVIS Director Subject: Waste Industries, LLC-Durham NPDES Permit NCG080845 Relief from Advanced Tier Response Durham County Dear Mr. Pfleger: We are writing in response to the request we received from Smith+Gardner, Inc. (Mr. Don Misenheimer) on behalf of Waste Industries, LLC-Durham on May 13, 2016. The request outlined the efforts by the company to remedy Total Suspended Solids (TSS) benchmark exceedances since 2014, and made the case that substantial corrective efforts and costs already incurred by the company, as well as the constraints of the property and prohibitive costs of additional measures, justify relief from monthly TSS monitoring. Based on our review and consideration of the request, the DEQ Stormwater Program is granting regulatory relief from monthly TSS monitoring as part of its Tier 2/Tier 3 response. Waste Industries, LLC-Durham may resume semi-annual analytical monitoring for the remainder of the current permit term, which ends October 31, 2017. This decision applies only to the TSS benchmark. A benchmark exceedance of any other parameter listed in your permit will trigger the tiered response actions as described in your permit. Upon renewal of General Permit NCG080000, the company may continue semi- annual monitoring in accordance with this relief for TSS benchmark exceedances, unless site circumstances or industrial activities change to increase TSS pollution potential (or other parameter benchmark exceedances prompt more frequent monitoring). State of North Carolina f Environmental Quality I Energy, Mineral and Land Resources 512 N. Salisbury Street 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 919 707 9200 The relief granted in this letter is also contingent upon continued site management improvements designed to reduce and prevent TSS in stormwater discharges from Waste Industries, LLC-Durham. If industrial practices change, site maintenance declines, water quality standards in the receiving water are impacted, or if other activities occur that worsen the level of suspended solids in the stormwater discharges from this site, this office reserves the right to withdraw this decision and reinstate the permit specified tiered response -or other actions that may be warranted by the new set of circumstances. Please retain and append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit. Should you have questions or comments regarding this letter, please contact Bethany Georgoulias at (919) 807-6372 or bethany.georgoulias@ncdenr.gov. Sincerely, Toby Vinso DEMLR L d Quality Section Chief cc: Stormwater Program Files DEMLR Raleigh Regional Office / Attn: Thad Valentine David Pepper / Waste Industries, LLC, 3301 Benson Drive, Suite 601, Raleigh, NC 27609 Bill Davidson / Waste Industries, LLC, 148 Stone Park Ct, Durham, NC 27703 Jim Azarelo, City of Durham Stormwater (via e-mail) State of North Carolina I Environmental Quality # Energy, Mineral and Land Resources 512 N. Salisbury Street 1 1612 Mail Service Center } Raleigh, North Carolina 27699-1612 919 707 9200 :INDUSTRIES LLC. son Drive, Suite 60 ,IC 27609 Check No. - 250897 Check Date . ;03]09/.IT;- v et .x ..r::<t�eY yyj p �ape�:•••• c •���++.s"x y� •ew FrS vC.. £�.1:. Y �i �-^e'i iiS �.3w� ':b:..t„� }.._���k`Aa� �:Sii�.4Xil.`�^u•• NCGUaUUUU ^NOI 'FEE HO)' 100: 001 . 00.00 i0o.66+ _-100.00 NC Dept of Environmental Quality Raleigh Regional Off ice x MAR 15 2017 Il°00 25089 ?11° Ie053 L049891a 00 2 2 LO L L466 L111 Georgoulias, Bethany From: Azarelo, James <James.Azarelo@durhamnc.gov> Sent: Thursday, March 09, 2017 3:06 PM To: Georgoulias, Bethany Subject: RE: Waste Industries LLC - Durham Attachments: City of Durham summary of ambient monitoring data for Northeast Creek downstream of Waste Industries.pdf Bethany, Based on our observations and data, we have no objection to your decision to alter the Waste Industries monitoring plan. We concur with your assessment that Waste Industries has made a good faith effort at maintaining best management practices to control sediment discharge from their site. Also, my experience inspecting the site in -person confirms your GIS observation of a long distance between the facility discharge and surface waters. Our closest stream monitoring site is located approximately four miles downstream of Waste Industries. Attached, please find a report of our monitoring results prepared by City of Durham Water Quality Specialist Susan Gale. Susan reaches a similar conclusion that, while there are some elevated TSS and turbidity values observed, the distance between the monitoring site and Waste Industries makes it unlikely that the facility is contributing to the sediment load. Feel free to contact us if you need further assistance. Thanks, Jim Azarelo Industrial Stormwater Inspector City of Durham, NC Public Works I Stormwater Services I Water Quality 101 City Hall Plaza Durham, NC 27701 P: 919.560.4326 x302101 F: 919,560.4316 James,Azarelo0.durhamnc.aov http:lldurhamnc.gov/9091Stormwater-Quality Please use our Email (StormWaterQuality0clurhamngov} or Hotline (919.560.SWIM) for reporting Water Quality Issues. Need to write a Stormwater Pollution Prevention Plan? Check out our uide! **E-mail correspondence to and from this address may be subject to the North Carofina Public Records Law and may be disclosed to third parties" 0 From: Georgoulias, Bethany [mailto:bethany.georgoulias@ncdenr.gov] Sent: Wednesday, March 08, 2017 10:11 AM To: Azarelo, James Subject: Waste Industries LLC - Durham Good morning, Jim, Our office is handling a long -overdue response to Waste Industries, LLC in Durham (NCG080845) regarding their request to reduce TSS monitoring given the constraints for further treatment options and efforts implemented to date (see attached). We apologize for the delay in attention to this; the Raleigh Regional Office is still without a supervisor and hasn't had staff to follow up on this for quite some time ...and as of the start of the month, we are without a supervisor in the Central Office, too. I've followed up with the consultant about some questions I had and touched base with RRO (Thad Valentine is now focusing on Stormwter Program issues in that office), and we agree they've implemented improvements and made a good case to return to a semi-annual sampling schedule as long as other management efforts to prevent stormwater TSS continue. However, before we finalize the letter, f wanted to check in with you about any water quality impacts. From my GIS resources, it looks like this facility's discharges travel some distance before reaching a UT to Northeast Creek. Were or are there any immediate impacts from suspended solids in the surface waters that we should be aware of before proceeding with relief for their monthly monitoring? Any apparent water quality standard violations that resulted from these elevated sample numbers could make us reconsider our decision. Otherwise, we will proceed with approval of their request. Thanks, Bethany Bethany Georgoulias Environmental Engineer Stonnwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethanygeorgoulias(anncdenr.ov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: http://deg.nc.gov/about/divisions/energy-mineral-land-resources/stonnwater .� "Nothing Compares% Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Summary of ambient monitoring data, Northeast Creek downstream of Waste Industries Prepared March 8, 2017 Susan Gale, Water Quality Specialist, City of Durham Stormwater and GIS Services The facility in question (Waste Industries) is located north of Stone Rd. at approximate coordinates 35.94905/-78.85441. The waterbody closest to the facility is an unnamed tributary that drains to Northeast Creek. The City of Durham has two ambient monitoring locations on Northeast Cr.: one at NC 54 (Site # NE1.2NE) and the other at Sedwick Rd. (Site # NEO.ONE) (Attachment 1). NE1.2NE is the most upstream site, though it is located approximately 4 miles downstream from the facility in question. Land use immediately adjacent to Northeast Cr. itself is largely forested, but many areas of the watershed between the facility and monitoring station appear to be fairly densely developed with a mix of industrial, commercial, and residential land uses. Site NE1.2NE is sampled during even calendar years. Water quality results were obtained in March 2017 from the City of Durham water quality data portal (www.durhamwaterguality.org) for 2014 and 2016, the last two years when monitoring occurred. Results for both total suspended solids (TSS) and turbidity are summarized below. Raw data are included as a table at the end of this document (Attachment 2), The two graphs below provide a time series of TSS (mg/L) and turbidity (NTU) results for January 2014 — December 2016. Marker color is based on field observations: red markers indicate rain occurred in the previous 24 hrs., and green indicates dry conditions during the preceding 24 hrs. While elevated results are to be expected during and after rain events in urban streams such as Northeast Creek, there were several instances of elevated values during dry conditions. However, these are likely not attributable to the facility in question, due to the distance between the monitoring site and the facility. ��� I I •I I • i� �i I I ii i� 350 300 72 5 250 ? 200 T 150 H 100 SD 0 M V -e le U") LO LO CD cD 0 0 0 0 0 0 0 0 0 0 0 a o a o 0 0 o a o 0 O O r O O Dat Figure 1 City of Durham ambient monitoring results for total suspended solids (TSS, mg/L; left) and turbidity {NTU; right} at site NE1.2NE, Northeast [reek at NC 54 for 2014-2016. Red markers indicate precipitation occurred within the 24 hours preceding samplings. Green markers indicated no precipitation. Attachment 1: Map of Waste Industries facility and nearest City of Durham ambient monitoring site Figure 2 Map of Waste Industries facility (upper right on map) and downstream ambient monitoring station NE1.2NE (Northeast Cr. at NC54; lower left of map) Attachment 2: Total Suspended Solids (mg/L) and Turbidity (NTU) data for City of Durham ambient monitoring site NE1.2NE, Northeast Cr. at NC 54. J L CO 7 Ubo C Station Resul Comment ro Y Y o o Q. b Name Parameter Date/Time t s `" `" u " U `n Y NE1.2NE TSS 01/21/2014 5 No Sunny 3 G Yes (mg/L) 11:15 AM NE1.2NE TSS 02/19/2014 78.8 Duplicate Yes Overcast 4 G No (mg/L) 11:11 AM NE1.2NE TSS 02/19/2014 58.8 Duplicate Yes Overcast 4 G No (mg/L) 11:11 AM NE1.2NE TSS 03/19/2014 12.8 Yes Overcast 3 G No (mg/L) 11:12 AM NE1.2NE TSS 04/23/2014 12.8 No Sunny 2 G Yes (mg/L) 11:18 AM NE1.21NE TSS 05/21/2014 90.5 No Sunny 3 G Yes (mg/L) 11:24 AM NE1.2NE TSS 06/25/2014 3.9 No Partly 3 G Yes (mg/L) 11:22 AM Cloudy NE1.2NE TSS 07/22/2014 41.4 More Yes Overcast 2 G Yes (mg/L) 11:00 AM brown and Turbid than normal NE1.2NE TSS 08/20/2014 12.5 No Partly 2 G Yes (mg/L) 11:14 AM Cloudy NE1.2NE TSS 10/22/2014 9.2 Duplicate No Sunny 3 G Yes (mg/L) 11:35 AM NE1.2NE TSS 10/22/2014 10.4 Duplicate No Sunny 3 G Yes (mg/L) 11:35 AM NE1.21NE TSS .11/19/2014 6.2 No Sunny 2 G Yes (mg/L) 12:22 PM NE1.21NE TSS 12/10/2014 60.4 No Sunny 3 G Yes (mg/L) 10:41 AM NE1.2NE TSS 01/20/2016 9.3 No Sunny 2 G Yes (mg/L) 10:44 AM NE1.2NE TSS 02/17/2016 46 Yes Sunny 3 G Yes (mg/L) 12:25 PM NE1.2NE TSS 03/23/2016 12.6 No Sunny 3 G Yes (mg/L) 10:30 AM NE1.2NE TSS 04/20/2016 11.5 No Sunny 2 G Yes (mg/L) 10:30 AM NE1.2NE TSS 05/18/2016 53.9 Used Yes Overcast 3 G Yes (mg/L) 10:54 AM sample pole NE1.2NE TSS 06/21/2016 5.2 Duplicate Yes Overcast 2 G Yes (mg/L) 11:20 AM Site Duplicate NE1.2NE TSS 06/21/2016 5.8 Duplicate Yes Overcast 2 G Yes (mg/L) 11:20 AM Site Du licate NE1.2NE TSS 07/20/2016 48 turbid, No Sunny 3 G Yes (mg/L) 10:50 AM high . stage, low discharge NE1.2NE TSS 08/17/2016 10 very low No Sunny 2 G Yes (mg/L) 11:45 AM flow NE1.2NE TSS 09/21/2016 167.5 Yes Overcast 3 G Yes (mg/L) 11:15 AM NE1.2NE TSS 10/19/2016 23.2 Yes Sunny 2 G Yes (mg/L) 11:20 AM NE1.2NE TSS 11/16/2016 96.5 Yes Sunny 2 G Yes (mg/L) 10:45 AM NE1.2NE TSS 12/14/2016 18.2 Low flow Yes Partly 2 G No (mg/L) 12:00 PM Cloudy NE1.2NE Turbidity 01/21/2014 20.1 No Sunny 3 G Yes (NTU) 11:15 AM NE1.2NE Turbidity 02/19/2014 114 Duplicate Yes Overcast 4 G No (NTU) 11:11 AM NE1.2NE Turbidity 03/19/2014 39.8 Yes Overcast 3 G No (NTU) 11:12 AM NE1.2NE Turbidity 04/23/2014 22.3 No Sunny 2 G Yes (NTU) 11:18 AM NE1.2NE Turbidity 05/21/2014 32 No Sunny 3 G Yes (NTU) 11:24 AM NE1.2NE Turbidity 06/25/2014 12.9 No Partly 3 G Yes (NTU) 11:22 AM Cloudy NE1.2NE Turbidity 07/22/2014 103 More Yes Overcast 2 G Yes (NTU) 11:00 AM brown and Turbid than normal NE1.2NE Turbidity 08/20/2014 37.2 No Partly_ 2 G Yes (NTU) 11:14 AM Cloudy NE1.2NE Turbidity 09/17/2014 7.29 No Partly 3 G Yes (NTU) 11:10 AM Cloudy NE1.2NE Turbidity 10/22/2014 13.3 Duplicate No Sunny 3 G Yes (NTU) 11:35 AM NE1.2NE Turbidity 11/19/2014 12.2 No Sunny 2 G Yes (NTU) 12:22 PM NE1.2NE Turbidity 12/10/2014 118 No Sunny 3 G Yes (NTU) 10:41 AM NE1.2NE Turbidity 01/20/2016 31.2 No Sunny 2 G Yes (NTU) 10:44 AM NE1.2NE Turbidity 02/17/2016 124 Yes Sunny 3 G Yes (NTU) 12:25 PM NE1.2NE Turbidity 03/23/2016 30.7 No Sunny 3 G Yes (NTU) 10:30 AM NE1.2NE Turbidity 04/20/2016 22.9 No Sunny 2 G Yes (NTU) 10:30 AM NE1.2NE Turbidity 05/18/2016 72.3 Used Yes Overcast 3 G Yes (NTU) 10:54 AM sample pole NE1.2NE Turbidity 06/21/2016 13.3 Duplicate Yes Overcast 2 G Yes (NTU) 11:20 AM Site NE1.2NE Turbidity 07/20/2016 155 turbid, No Sunny 3 G Yes (NTU) 10:50 AM high stage, low discharge NE1.2NE Turbidity 08/17/2016 25 very low No Sunny 2 G Yes (NTU) 11:45 AM flow NE1.2NE Turbidity 09/21/2016 297 Yes Overcast 3 G Yes (NTU) 11:15 AM NE1.2NE Turbidity 10/19/2016 64.5 Yes Sunny 2 G Yes (NTU) 11:20 AM NE1.2NE Turbidity 11/16/2016 142 Yes Sunny 2 G Yes (NTU) 10:45 AM NE1.2NE Turbidity 12/14/2016 41.6 1 Low flow Yes Partly 2 G No (NTU) 12:00 PM I 1 Cloudy Georgoulias, Bethany From: Stacey Smith <stacey@smithgardnerinc.com> Sent: Tuesday, February 21, 2017 1:32 PM To: Georgoulias, Bethany Cc: Bennett, Bradley Subject: RE: Durham Campus Update letter Bethany, See answers in red below. Sorry for the delay, I was out on the road all of last week. I have another question for you and will call. Thanks, sas Stacey A. Smith, P.E. President Senior Engineer SMITH + GARDNER 14 N. Boylan Avenue Raleigh, North Carolina 27603 Ph: (919) 828-0577 ext. 127 M. (919) 815-0803 www.smithgardnerinc.com From: Georgoulias, Bethany[maiIto: bethany.georgoulias(&ncdenr.gov] Sent: Thursday, February 9, 2017 2:53 PM To: Stacey Smith Cc: Bennett, Bradley Subject: RE: Durham Campus Update Letter Stacey, We will respond to this request from the Central Office and copy the Raleigh Regional Office on any correspondence. Given the absence of a Supervisor there right now, and the history Ken Pickle had with knowledge on this site, as well as the information provided in the correspondence from May 13, 2016, our office can provide a determination. I do have a few questions as I'm catching up on the details of Waste Industries' situation: -How many outfalls are at this site? From 2015 DMRs I was able to access and the info in the report, it appears there is just outfall 001, but I wanted to verify that. Yes, there is just one outfall. -Wham with the City of Durham should we copy, to keep their program updated on DEQ determinations for this site? The City Stormwater contact is Jim Azarelo james.azarelo@durhamnc.ov -Did the company consider any innovative Stormwater devices as alternatives? For example, StormFilter by Contech is now included in the Stormwater Design Manual in Part D. 1 as a device that removes TSS (and with certain media, nurtrients). I'm not recommending this device —I'm also not familiar with the design or siting requirements in much detail because it's normally used in the context of post -construction permitting —and perhaps a proprietary treatment device would be just as expensive or futile here, but i am asking if any proprietary devices were entertained during the evaluation process. The City of Durham may have experience with these or other devices in their post -construction program and have thoughts on it, if this is even an avenue worth considering. (Maintenance would be a large consideration, given the nature of the TSS loading in large events.) We did utilize filter bags in the boxes, some regrading, and to position the sampling location to allow the stormwater to settle out. We also looked at constructing a bioretention area. We believe the issue is that the flow is concentrated to a single outfall and the entire site was designed at a time in advance of the current practice with stormwater quality. The runoff in a 10-year/24-hour storm is +/-100 cfs. In review of Storm Filter®, it does not appear to be able to manage that much flow or a reasonable cost. Thanks, Bethany Bethany Ceorgoulias Environmental Engineer Stonnwater Program, Division of hnergy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethany.georgoulias(i�ncdenr. ;ov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: htt :Hde .nc. ov/about/divisions/ener 7 -mineral-land-resources/stormwater —>"Nothing Compares K�C. s Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Stacey Smith [mailto:staceyC@smithgardnerinc.com] Sent: Monday, January 16, 2017 9:19 AM To: Georgoulias, Bethany<bethany.georgoulias@ncdenr.gov> Subject: Fwd: Durham Campus Update Letter Bethany, This is the letter that we sent to John Holley and our correspondence. Our client, Waste Industries, wants to and intends to remain responsive to this situation, but would like some acknowledgement that until DEQ has sufficient time to review and further discuss options, that the site may remain in compliance until further notice. Beyond our initial letter to John Holley, 1 have only contacted him by phone. The last time was immediately following our last converation. Thanks, SMITH+GARDNER ENGINEERS May 13, 2016 Mr. John Holley, P.E. AMPISS irl WEB 14 N. Boylan /Werue, Raleigh NC 27591 919.620.0577 www.smithgardnerinc.com Regional Engineer Division of Energy, Minerals and Land Resources - 1628 Mail Service Center Raleigh, NC 27699 RE: Reduction of Monitoring Frequency - Evaluation/Request Waste Industries, LLC — Durham Certificate of Coverage #NC6080845 General Permit#NCG080000 Dear Mr. Holley: On behalf of Waste Industries, LLC - Durham Facility, Smith Gardner Inc. (S+G) is submitting this request/evaluation to the Division of Energy, Minerals and Land Resources - Stormwater Permitting Program (Division) that a reduction in monitoring frequency be granted. We understand that the purpose of increased monitoring is to gather data for evaluation, not merely for monitoring sake. We believe that the site has compiled enough data to evaluate corrective actions taken and proposed on -site, therefore making the increased frequency of monitoring unnecessary. This document includes/evaluates monitoring data, costs and feasibility (actual and projected) of corrective efforts attempted/evaluated/rejected on -site. We believe that this evaluation'shows that the effort put forth by Waste Industries has been substantial and that additional effort, other than general site management items, is not warranted at this time - 'A drawing showing the existing site conditions is provided as Sheet 2 in the approved Level 3 Site plan which is provided in Attachment 1. CURRENT PERMIT STATUS In December 2013, the facility officially entered Tier 2 status (NPDES General Permit for Transit and Transportation) after twice exceeding the TSS benchmark value of 100mg/l. After the February 2014 monitoring event, the facility entered Tier 3 status for TSS and official notification to the Division was made in July 2014, including the plan for the installation of a Stormwater detention basin on -site. The last official update to the Division was made in November 2015 and notified of a potential change in the location of the; permitted basin to a newly acquired parcel to the south (evaluation results of this new location are discussed below). Subsequently, in December 2015, an inspection and meeting at the site took place with the City of Durham Stormwater staff. Before the site moves forward with more effort, the City ' has stated that they will defer to, and agree with, the Division's decision on the reduction of monitoring requirements, as well as, the amount of effort required to address this TSS issue. rt Mr. John Holley, P.E. May 13, 2016 Page 2 of 6 The City has asked S+G to keep them informed so they can add the Divisions comments on this matter to their file. S+G contacted the Division in February 2016 to discuss this matter and the possible submittal of this request. STORMWATER MONITORING RESULTS DATE TSS (Benchmark=100) Non -Polar 01 G Grease (Benchmark=15) May 2012 855 0 September 2012 19.6 0 February 2013 11 4.78 October 2013 280 13 November 2013 500 8.73 December 2013 171 <5 February 2014 712 0 May 2014 424 14.7 December 2014 980 <5 March 2015 536 0 October 2015 26.5 0 November 2015 456 0 December 2015 52 0 Additionally only qualitative monitoring was performed during February, March and April 2016 as no events occurred where the first flush could be sampled and stormwater flow appeared typical of recent sampling events. Data Correlation S+G attempted to correlate gathered data with the below corrective efforts/site maintenance items. Direct correlation could not be found as the size of the storm event/velocity of stormwater appears to be the driving force for the TSS issue. These types of events often over power on -site maintenance measures taken, making a reliable data correlation impossible. CORRECTIVE EFFORTS The site has attempted/evaluated or rejected the below methods of corrective actions. The site has been responsive and thorough in the attempts to address this issue, and provides the following information as an evaluation of such effort. Site Maintenance Items Several general site maintenance options have been implemented at the site to attempt to reduce the TSS levels. Below is a list of several improvements that have been utilized on -site: • Re -grading of parking lot near drop -inlet; • Use of sediment collection bags in drop -inlets; Mr. John Holley, P.E. May 13, 2015 Page 3of6 • New aggregate with fabric placement at select areas of parking lot; • Installation of rip -rap channels in high flow areas; • Check -dam installation; • Wattle placement; and • Movement of outfall location. These options appear to make overall improvement in the amount of sediment leaving the site, but only during very low flow events (less than 0.171. The large volume of run-off typically present at the site appears to "over -power" these installed options. While Waste Industries and S+G continued to evaluate these methods, additional design methods were evaluated and are discussed below. Skimmer Installation S+G evaluated the installation of a riser and a Faircloth skimmer at the original outflow culvert. This riser/skimmer would be constructed without building a pond, and would be located at a low area north of Stone Park Court that is the invert to the discharge culvert (location shown on Attachment 21. This option was modeled (using the runoff from a 1-year storm event) as a mini -pond, to determine if the skimmer could slow down discharge sufficiently to allow some of the suspended particles to settle. However,�due to the drainage area (more than 10.8 acres), even the 1-year storm event overwhelms the skimmer and discharges through the culvert in less than 2 minutes. This calculation seems accurate. The total storage available in the "low area" near the culvert is approximately 5,000 cubic feet, white a 1-inch runoff from the drainage area has a volume of nearly 40,000 cubic feet. The available storage is not significant, compared to the potential runoff volume. This method was rejected. Flocculent Installation Installing/utilizing flocculants on -site were considered for treating the runoff. It was determined that the high velocity and amount of flow that is typical on -site would not allow for proper mixing/dosage to occur. Additionally, it is possible that flocculent use at this site could lead to greater sediment deposition off -site due to outfall Location and run-off velocity/ amount. This method was rejected. Biorelention Areas Bioretention areas were considered for filtering the runoff. Two available areas were identified on each side of the driveway access to the administrative/maintenance building (shown on Attachment 2). The areas were each about a quarter of an acre, which was too small for the contributing run off area. Additinally, about 75% of each potential area was within the required buffer (City of Durham) to Stone Park Court, so they could not be available to use as bioretention areas. This method was rejected. Mr. John Holley, P.E. May 13. 2016 Page 4 of 6 lot Paving While it is possible that this option may improve the runoff quality, it will likely 'increase the run off quantity. The quantity increase may lead to increased erosion further downstream. The cost of this option is also substantial (cost breakdown is included as Attachment 3). Combinations of these factors lead this method to be rejected. Permitted Basin North of Stone Park Court S+G and Waste Industries decided that a basin installed on -site would be the only feasible and most effective way to address the TSS issue. Subsequent to the notification to the Division of Tier 3 status, S+G began the City/County of Durham submittal process for approval of the basin which required a Level 3 Site plan (Attachment 11. The process took eight (8) months and approval was granted on March 31, 2015. Items related to the design/permitting/cost of the basin are discussed below: • Available Space Conceptually, the basin was limited due to the available area for the basin. An initial idea was to construct a wet basin in the area north of Stone Park Court, but there was not sufficient space to allow for a forebay, a littoral shelf, or the other features needed for a properly functioning wet basin. Therefore, the conceptual plan was to construct a dry basin with a skimmer for outlet control: This would slow the discharge and allow the suspended particles to settle. Existing Culverts The permitted basin was constrained by three existing culverts. Two culverts flowing into the proposed basin area from the east side, and a single culvert which discharges underneath Stone Park Court to the south. In design, the bottom of the basin was restricted by the elevation of the outflow culvert (EL 368). Installing a culvert at a lower elevation would be prohibitively expensive, due to the road with water, sewer, and other underground utilities. The maximum water elevation in the basin was limited to prevent submerging the incoming culverts, which could cause overflow issues at the upstream drop inlets. The maximum water elevation was limited to EL 377 to prevent overflow in the upstream drop inlet. • Stone Park Court The size and maximum elevation of the pond was limited by the elevation of Stone Park Court (approximately E1375), The permitted basin included Mr. John Holley, P.E. May 13, 2016 Page 5 of 6 building up the embankment near Stone Park Court to EL 377, as both a visual screen and a means to increase the freeboard in the basin. Setback requirements The basin was designed to hold the approximate volume of runoff from a 10-year, 24-hour storm event. However, due to tree canopy requirements and to set -back limitations, the potential area for a basin was restricted. The'resulting proposed volume was equivalent to approximately the runoff volume from a 6-year, 24-hour storm event. • Rock After design restrictions and eventual permitting of the basin, an investigation to determine bedrock depth was conducted in the fall of 2015. Bedrock was determined to be from 3-7 feet in areas of the proposed basin. The rock elevation further minimized the cut available to shape the proposed basin. • Cost Waste industries has spent close to $70,000 on the basin design/permitting, bid procurement, required surveys, and investigations associated with this basin. Bids received to construct the basin were from approximately $300,000 to $350,000 for the base bid price. An alternative included to remove soils from site (an on -site stockpile area is not available) increased the bids to approximately $416,000 to $516,000. This basin was ultimately rejected just before construction was to begin in the fall of 2015 due to the bedrock restriction discussed above. Basin 0 tian South of Stone Park Court Subsequent to the determination that the originally proposed basin Location would not be suitable, Waste Industries purchased the property to the south of the facility (Lot 4 shown on Attachment 21. Conservative preliminary estimates showed this lot as a suitable new location for a proposed basin. A site evaluation was performed including wetland and stream investigation, depth to rock and required basin size. Available Space S+G utilized data obtained in a wetland and stream investigation, depth to rock investigation to develop options for a sediment basin size and Location. To achieve the stated goal of TSS removal, the 10 year 24 hour storm event was chosen as the design storm parameter. Analysis of this storm event resulted in approximately 151,000 cubic feet of required storage to fully capture the design storm. Scenarios were evaluated, with each having sufficient capacity to hold the 10 year storm event. However, depth to rock is similar in this area (outcrops to 8 feet deep). There are Mr. John Holley, P.E. May 13, 2016 Page 6 of 7 storm event resulted in approximately 151,000 cubic feet of required storage to fully capture the design storm. Scenarios were evaluated, with each having sufficient capacity to hold the 10 year storm event. However, depth to rock is similar in this area (outcrops to 8 feet deep). There are also potential wetland issues that would need to be designed around. A preliminary figure relating to this basin is provided as Attachment 4, Costs Costs for this basin are estimated to be similar to the basin previously discussed. The design and permitting approval through Durham City/County would need to be repeated with another Level 3 Site Plan. S+G estimates $50,000 to $70,000 on the basin design/permitting, bid I rocurement, required surveys, and investigations associated with this basin. Construction estimates for this basin are similar to the previously approved basin with a base price of approximately $350,000 to $500,000. For this basin project to move forward, an additional, substantial financial commitment would have to be made by Waste industries. The site would have to go through the design and permitting process again, with no guarantee of approval by the City/County of Durham. CONCLUSION/REQUEST We believe that this evaluation shows that the effort put forth by Waste Industries has been substantial and that additional effort, other than general site management items, is not warranted at this time. We propose that the frequency analytical monitoring on -site be reduced to semi-annually, as we understand that the purpose of increased monitoring is to gather data for evaluation, not merely for monitoring sake. The site will continue to implement best management practices and wilt continue on monthly monitoring schedule until a decision is made by the Division on this matter. Please contact me by phone (919- 828-0577, ext. 224) or by email below with any questions or comments. Sincerely, SM Don M. isenheimer Projec cientist, ext. 224 donfdsmithgardnerinc.com dmm Attachment Cc. Gregory G. Mills, P.E. Sr. Project Engineer re mfdsmith ardnerinc.com pQ`� rod Ste. 024935 a I CO WASTE INDUSTRIES- DURHAM FACILITY DURHAM, NORTH CAROLINA STORMWATER BASIN.-'-_9.EXPANSION - LEVEL 3 SITEPLAN vFxwroxAwinss ' li[�:11M:1' •' PERMIT ISSUE] NOT FOR CONSTRUCTION i IlLylaEU. MARCH cum , SHEET N0. ORASMNG N0. DRAWING TITLE REVISION NO. J0,'317E- COPY 1 TiTLE - COVER SHEET a.w� .-,.. corm•' ww•n:+• •. . 2 51 fJD5TING CONDITIONS 3 52 STORMWATER BASIN GRADING PLAN- 4 S L] wLANCYaC.4PINGPUW m wmcxcrnw-+rn lr.¢Tlbrl.4w! 4lfW.KT+O wp-0}/r Y+ W4S ��M101ElI.f� raaeNr ws ra®us., rw�.ranwxwn -n wow urr AlaAww Amer+n.+� SPECIAL CRND ONS DP APPROVAL .a.� .�..:w...21 �n rrw � w...ww..�r n•_`� wyrta C.nsr•r•4 "TY� w�.r� Cw.wrrlfr•r,.r • wrr wa rw w.r r rwr .e.ww. w�...wwwra..u....w.r..r.r� KL'CNa.Clmw a&7 kQ SMITH-QRDNER Ie IL8*mAw=,RYi XC2hM I 119.CT9= R�sr�nwr..WwtiwMr.ayw� d-wry-ytir.�rww' �wR.�wrr',tM.r��w�rww�w q,rwwR.Mxw. •Tww+n�w...n ti� w-�. uw. �d �. w e :IR RAF AlAWiO r THTolleweA arrmlmlr LKATION m,awww,e® �e¢wenY+a wA� STANCKRO DETAILU1.LDOr �on.a au.;mm ST�DEr��'D�LUI DETAIL MLE Plra Ao.r,ea� aw.T>•�ecnA wa>R++m STANnARD EMMN r,ALLvur 1srcILCT�No oLTm.7 — yYQIATA�IaIMwlwlNl tt WJSTEINOIISTRIES,LLC HEIRHAMFAGUTY T48STONE PARK COURT r�.--------- --- - -- --- - ----- 1 --- - -- ilORHAH.NL2771)3 7TJ3 'fir ' r' �„ �� ��� �� "�4=�__...-_.�.�Y�- ___-_•._ _- _^ _ _}/-/-�-'_ -_ �/ , .E,CSfNi _ `1 can ukseww.l .'.'�'-� r .�' ry',� e � `�5�^�� ,� � �'•,r�� s;�_ -- ___� _ '__ .-- _ _ _ _�_I / ''' -.,,yam �/apf,•-. or ..� .;-'"�R1P� _ t'(E]Pl-. 111P.)m �}+r'� '} ` SMITH+ J r ��h �� � � l l.-[. .�f�.- �� C -� ♦ �f1.,. ]: l�-lww/v.tw-Y�4 �ur�L.,a -- ` 1 ~. f ~ ,.(.✓^= 1.6� " }__ {-�. ..,..0 . " �,f.r�w , ram; - ``� GARHNER 'aw\\w ' .l �'° n/ sr' i '� - -=q- =C_f ` ENGINEERS nRtPlU4,SluI I�i% x I ' i! .Ir.+...w,cma4mgkan .I.�2iE7r� r�'��i 342.8 343,6 cxsa� eels %i _ r-•- - _ -- + 'I ' � am) r./ ;i_-"_ rr•_`_�'r`� :/ /�X j'-. FI Ir 1'\ :/� �✓,,:`.% � ,�� / �.; :Ii 38 .5 + � / 3-_��' S7,..'� - rn r �±/// r}I .91.7 T I ADWUM ME >RAxacts��+w {x' (.4l RFFilaIQ .E7/ - /_i �Yr ___ Kai-_/ `raN''�< ,.� aF'-_ _�✓'',--""i _ Y I __ �y iisilfl ./ �. r✓/: ?f� �+�� ��ri'�' y ��,��j^��wr�`.`.¢�� � y ��_ 'td1. r' -ti l �I `•� � rl rl �+i� it 76 i i - �`�� ARV=E h171Y<______� •/ `� ,�- ~--- 1 - '1 ,11 _3 �.- -.�1 z, PERMIT ISSUE -------------- NOT FOR CONSTRUCTION _ - N +, �.� - ��r` ' ._ -may.. •.-.--.��' p�xrut•.__'_�� •__r.'r `r1�K+ I __- ' � y `tl -�� i 'k IFIDQ �...r rj.., -J'_�/f +-_ -��� •+�,.�,y��- I f �vYv'�rC ���'�` ° a+�s� � � `-' � I�.�..rr•� (s�.Rrrml�A `l , t i \�� 4• ------- � ��*Riakwu _ / /w • rY = Y� i ...w � �' . fi.�,��Jjp�>�1.%F�` /' I `f + � I Yl�uk nuutrf u[ p¢ kmm L L»ICtaut---�yy- ArFWWIZIAMLT iLC5�7�4'9Pr J4,%/ �\ y_ / J ,szear�.. ; ' 1' ;I —os wsxoe,.�.. STORMt'ATERMal EviNslOR -'�i/ ,' Y ', ,:n• _.__ ".".*'4 xf:.� � -;-_ (7h'il��--, _.-� SItRv� '7}:7�'I/I ✓ _ \ i t _I —' 3 awv,vur.erwa 1EMISITEpul J 11'� " �'./� _ -_ � _ ���., - '�. .tiy i. 1l� r `\ 1'• _ -- — -- 11IIK GGn! f , / r ' - r-' .• 'Y i-c l ~ f . `: . r I 371.]¢�.};i mlrs r .',tom:, /_ , 'svl, 4 ._ `\r.69_•uofun�araerwyr �\ ' 'I ,`j mro�amlslen�>m>ux�wrwv�EASTIRfiEUROIFI01I5 \ / / 9AZ MLd1L 4k. +`m� 57L .7• G /` '; .. S7' lj nv�+[+o .nlr� _�Q`f.sfm -=_ _=:_r.'Fx3'�i 'ti( �/ ' I `�� '�1 � � 1 ' '�~� e�io�m,rrenl lu+�a>Q4[*n I'ft+`_rl�,� ~ `�����-•,--•• � --. � _ -! 4� -�f�ri�+�� -_- /:. ,� _" 1 Sitl1Y9R px10r /OMIp<pIOO11NafQrS! CI,. usluM• ^ "�� - � akWpOL EflGOM1 Ile 1``' \y��;, A-Idl a,1�6 aW Yi fYllfi IR aek ,ga1S 1G f a r I 2 Sl N[INBIIFFER $EEOINO RFd11fliMEN15 _ `Lt •`�`• �.\•`'`,` ~ �_ f-0I g015TUR�RkKk5IXR9QE exEF`SRiRFFY IJritm WASiEINUHSTRIES,EIC v e`j_=. DURHAM FACILITY 1 m�.cussFx t QS.FRE M STORE PARK COURT _ \`\ RSIMRE vote -- �-- ' f r .'4r' r, - ��` ---� ` \ • ,•' ; 9+�9EA I`A L@SIa�E OURHAKNC27703 __ � , � ,: , // r -' `- _ ' J 'S '' •'� `• \ ``, L `'• xVLCH SEtl LBY.CRF I -�_ = '�• • 'TI / ( r =r' _ -__ __ ._-- _ / / ; ! ` i. DRERMRrETxFKYLIMrf EQ50.lMS _ REPMEHi11NE fCIWM55SW — RFRI [O NpTARhY W11M�Ex BFe[iR[ `%'/ ,, � y"r f V.V',{..aar�{�_�._``'` -- -___ `� % 1' � '••'A 1NF SMIEu50lNUR.aIfO. m« rF 4E➢NGm MILBSlWai09alF➢. r'r�%�� yeµ,:-04-CC-.F"-u_, .:_siq��`tf'�": 1-<iz3.�__._ -`- �~ -- - _-. ..�.�?�"' !�, -•-J�✓'�'�)nrsLtaEUL'uRSFCRorsewsEeaNrnEfIXIFn»a SMITH+ , ��Y4 �- - - �• •� • \ { ..�-K�, �.�_ _ ' - [^ f' lv'_�zV•} L.^ I t• �% [BAMR•1 i0 Ar1A E] IMVIhL xR CRMx I- �,3, _� ^Tr I a 4-�• o y x ` - ....r: K...., w.l�e,"..,.' - r J".-f� /l � ! ,E' / YeIEMKAI NpFxrlR IS rRNRtML mFIXwx ,.`.'•'.'`[s3�'?� GARGNER ��/ •���1 / ✓.t" at., 1 1,p,-1� \ 1 _ - RETe'�-� / MEV.xRFRv mD ,..vA:.ei .wYrERmF ENGINEERS rw_•.._.- -�` / ti; --_ ( lc58 /�~ "�--' /�i r;Yi ,l '�!�/ :rr•' ��r �y i r`..`.� ���� -` 1' 3_i,, t'I �• I)i III IS"!'I j r �%a 5� / k r /Yr/�'r' -f ';i _'MIIpS�.1417'/YI fdSEi[N7, I F 4 %� 7 ,C J2415rF.r57A+Pr/ � -- �:✓' Jr'r /- �'`� � 'r'=` � r�� 11�11 't I �.I I[ +1• � r �---f>A ($�7��� � p�.'S� •�tlr f,'.'�' Y lJ.: '. J_g���J 1 5 1 � 5II - � i 4 II� r AM9957VW NO '?'\j_� f � /j/- .� !. ri •� , "%tom" / 1 �1 � y I ti Itc� r. i r / d.'SRt.FFNCE(TYP.) s \/' I ' -- Ol w / OF DISTIIK IANCE lull! � I� FIC r"lA7/Y (UAY ElEVfA WM,375 FT' Na)) �,�„ 1/r� , :'.A7'.surrNxr ,L ' �'!�" Z. _ i �'� . Le � i � _- - " g �ir` � � - I r i 'ts- �.= __�--- s•.a % J 1-K �EKIL1D Fu5RfP_�y��ruc iit -'.Y_:mr,, S A'9$�'lRp+-fFF111.y �" Cw Y=13-i� %' /' /;/�y/� --- .l(36•Iy � �-_4_i � � �`-� 1 `. L .'' /Ear• -�-`- "-<- - -- / yl.e�+5e�sl+o+es ee nvrtanc wu[xR:a - r�rtaurl��ap _ f Aa i �RPILi Rl , �rS.l Q 0/Irni �QQ a!M r� RN .•js- a1 I wr � r �`, .w eeml� air .+[-Rain � r.wn rv®q mm e .c / _ � '- 1s':p� `,�,�wl / _ ' _ • � r' �,l : .m �u n nl m.n N,w. Q.nRwr _ _ � _ /�� / ' - _� �. _ � �+ �f'� " FIQ R IaLLiIL REIaMi x nuL lub RNR >m u ..�__.-..... rIDRmY tie • /ffI ,� !'� _ -•iT "" _ i /,U'•`""':r�^• 1 ali i � no A�� a R miur arsr u w e xwREa -177.E / - we GLOW � NiO. • __ - - mnw¢ wm w nRrlc NLs m ralNNr r a®om _ _ _ _ .+Rm.r RRaensur!>Q aun t . Rm x Rn+maa co>& rrt _ '' .�++ � ,-- ' �� � �� ���I r--._�• r'?r e� a'�N�; a�nac+�n r�Rrr�m,F.s,,. _` � amar DEppmCCNS1Ri TED RAa 7: 12, "p (ALTFATh'2) rxr//0u"r�r_a_oIewI- Ss'm'a rn/ a FemR�crnM pr¢u {v,mQRtFo +hm�Yae�ReenRia4rFRaoRuna ----aRu---®- .wr�rr..RoRrr'aaxs nR+rRrlr a. awes •S••,_RMNAlER 9A1R WARSM C' 1 ; �� a lnu�'nou rw. us Reou. F>sar rr url.R� LEY MITEPIAN — /�EIRRCF7ICY_ SPILMIAY (EL' 315 LISL} _ -. _ ,• t= Y 1 \ I RLs . RloQn Rel rrlR x IRearx lame x .arc Id.l EQr•iPe rn Q �'t.S�;. r`��- I'•� �� 'ti, 373.21.1 i it - - +.Qlc.�T,ra irea rxr..mv m.e cem 1 ' ' - ' f (� -: - �• �.y' '•. ,T, r' ,'` - '.c� • o.� -... i�i- 5 • :I I wac rm� R. It+F.vc Q lax sou �.aRc m cR �-:.-., - ><t �t � / j• - � • � I.. � SAKF Q bYL A 61R1 eaR, lmlr.A IN aNL x RRY RI 369 Y.,_ '{, •im•�e nocaQu tao eamna A<.xmNxi O sRnm x;;ew,rn.. Si0 MWITER U1Sl .Y r EI ;'R I' a ( i eaole alu eE Lalum a x a e w on lurtsr kL4TFS R R L , •r I' -}F� -A YIK Y,, •. / 1[Ipux9W N1R.R Ra6RyL plORr PRRS 6R9AiI Q1 .✓•o �aN Ir38 :._�r�r``wl / r __ n..n-u-ny.__' r-% I, ma.ea.RE onQlremaeanecpaaiaQ lraa•�aia. SAAGIK6 PLAN ' I f .'�.f'r : a•a wi �r >' I ` 1 ~ ~' x J �•� » _ �• "_• S /. ..r�+as aLatalla iscv�srL.+uRo >t o.a.eL ram.ca ncm.rlwaroRxsr I%r.y�-•. • }��'-,. yli5 Hti.` - - -- ixasa.xaErE+RRrorEvr a _ 5, -:a•'S ib,`-�•-_�---��--"`� I'� - � b.evra wvre nws wnnsr �4Fl / - rreSc irRQ icRc ltf �./jrG.-:�`.�-. r � \_� � ,l i-�- \•�'✓ !rr �,� F>�56 u�b.rxa rwo�wRnamSlA r.m ' ,. , r/ ra'.r w+saRr• aRErrRa _ _ - 'r :. -' "-- � M ` +�� h i1 1 m S`-.=r`n-__--,Y.__.:____.�_ ,5`i4.7� `IC Il I. rupn mar.,ro,:.. r9frur RR.r ns►rtnc ``tt �: is.-_, �i - ��'•\`--�' / 'EIS gIXIEN.E NOIES cs roww•tar --�J brxR¢ xLl� ern/x 'TV-' PERMIT ISSUE. ,�•�E�. r r - - a,t. � 3 r �,!-/'r '1r im�wEc m�a w'�RsaR Barxaas N:raasLou s� w��n�m•. s�¢r�onmire��ao. re .. sEri.LnR NOT FOR CONSTRUCTION `aY"rF I.m R1wnMIM 3R52 a'mv�.ut..•�.,r �, Q.A1 x u m:Iaa M[ ,ax r u. si�uA � uuw oNt+s aY 1 Y14Y�9m�®O,94N 9utf lA'M fllm lwlftl 1 r ,arF np.l aao rrt a o r .,uoo io ac WQ ann swlcxe .. wmwr m.ctrrrt ♦ tlQQ A.�L91LA� Y f1W([ nuE A IMY A • N A A IAri 4Y�1tL S r.ptpM 111E p ri}rPr flrl A [ ITfl toc p V1r �aa m rva �'-1 Rw tam. r.ou ray �-m'�'� •a wrapo-n lads [mr rp m r I.aol CONMEIE PIPE RSUCLATICN a (am RM fAmm am" FPE AZ"70 QEDQ4T 700 lillo m EMMM0,01 NSTALUTIM SpS"UK" CfQPACniYr AEUR+D015 reawerQr rn,t .mca "a'O'"a my ,mere Iot:w I9t ��� r_YOIPGet rM QQ MSf ben 1rf: Y4p CS NI ®ILL 6a• E'C w�ifE•�wM-1 pSs0. rl YaCp pR0.r. tLZp I. mNSa 110911t.65 (w pY emAi A A h rWl gym] a.UliGVj •r, r>it p�llle r6Tl mrCM �#. � wl . rn t Rl .11[ a1P k'ar4 Mla Ira Lin Ar t,d FIDE.aF M r� N rsl awor, llrl [ mlYJ9 A n mKI M tt[ LaratllN 15 .( MYrh tl R � M K ppC �drr Q1 r 1� ♦ i�.�.I�.wr+r �-I r� CCNCRETE AR -SEEP CDJQ A r� 91F rOQ 1 ra SgmA J ELM Nrna A� oaxt •!i W ma. [.4t9 77 mace u ptlo ioaa. MQQ, arR / r.r.�rwAa mace xa: 4� s[ d merco mom slm ®e CONCK E PM PERMIT ISSUE NOT FOR CONSTRUCTION runs mai w �IwL in, �_h"o rin.,ty Doan l roa pvvr mm p it ws x ,cn, ®tenon �mlow raa+e msoorn 1 mrlL mpnlQ t�aE1, pA h C' k]rfllC�St .anl .-ILti Glfi K R61FUIbW 1 rcR tOi R V eia � rotS.ID) 9lLL rt . Y f�[�4 a[ NL �Ohn a! i �_ n�lammrm.s is . r.ss. v .mrm o s rott.rrm pub •i ur .D,l oc nw � man m r 1+,1 to a ran wwrt,eKw C'pvt.p n+ r t4, Men vAolq n Rni IMS .irno x w 9JrOrFIV VNrc ImQ rM rU,Sa[ p w l3 � - mli 11r �,aar Y 1- r f llll IlPatl C RO rrR x Z+IQ, 141. t,99.@ Q Cq6 rr! IE �Q tl R Ra- SLT FENCE 5 R1 Ia la ] IQAOJI I.� rimb rcvwx1-r x DECDU S CC 6MLC1ED elff}ER - ALTERNATE 2 (CPACM O.2) 11 SF FBa PV. - '' � wV `� tY15 0P FsbTlrrBu; 0-e rFm sl (WI)- POFasm'amL Mf0. ]75 Ff (Yiij � - `r.•~,�• WASTE INDUSTRIES, LTC DURHAM FACILITY mosTRNEPARK COURT DURHAM,NC277113 I[t hfE Fl rpl! naern b lra.lp > �u.rawRar,l6 tvM/nrY r,woaoMfnr[.frSPMCPrnry 6 SA J ]1 r]Yraar Mll. MiNMr M � n..�.• l.M� 5IRJ6 -i+. Yt•Mwrt.w MOCI}�tA� � -- . � ii.ial.wrlR SMITH+ m1al69NJs - iwiah GARNER ENGINEERS Ne Y1r�RRi N•L DEtl � IlanB: RE SE v.era+ uwm.irw. orra.sl � �• ] .v.+a m.ma / elate lom�i� mrani..we,...�� w.W.Y.v vc.r.�a.r.i]�.uvx .c.. —_ _. � __ •' ra..�r..ua+.+.+�•�-.�nr,�m.ar..c�.. rrwrrr.wrr....rzs..Muu...r risn..�.,.—` �� wvvvelri.. "�. mr (ie) Cu.= sr aF osmsl ='4"S PERMIT ISSUE NOT FOR CONSTRUCTION s (x,DWZ2) -ffumumcnONAMA ..s.. s PAOMM F3AFUR tr '- '�' T"i"�= :�7'w'�..ii m mmb iiwwc ri A �.Ex _ _ _ _ _ _ — Rmil°° xl— u r �•" ± "�'!"� , • ..6�..'�»"�^� "�: ,a, ic�-are�x �t 4�.. sS.- � asnasiti .�EQ it �.wri .e r.n �Je.a .n .i ...__._.._.- I.r�Kn canal .r,..�� •G==-.r � y !' �k�' ,� �-�, -.:� T � � `na rnm.m IH � Aa`° bus �vrn. a urs a mw.a rs.a.:a .3-, - p�� T:� uo]s a[nnnlc xnmrmavo.remrawrt ^--- awrrE�vn�Ju omit tF _ fu wai 4.i� ;+�? �+S•pl =..�^r I 0. q Cf P ac rUer af! u.YSAI®INOTJI! - - 1M�1] }L �' n ill�l MW mLC.I >•s W SNk1111A1ER BASLII El(PArSLOk .m...ra.._a e 'L�.�� y? �� .sr.x >.aMreyeamxemus�]nvatart,ncravE —ws— EYAaJIIMTP! LEVILSSITEPEAN i'k a au.e >oa raim .cr o�ual —.� aas.sm ur it wea � I... ..x, i�;F�^t:cr._ _>:�r,..__ ;: _R.. �-:� ;E St.Yl�ii�n - +[�Pae�j a.r� rr.wJm•--------' tme�v arAlr� -', _ .-.. r FnSa'1 . imr..uin mrc uo ac w lmlu n. iom Q uom rP e..nire.a.a-.:.a.�a,..K. :<=-!li:`-+"�,� �`_�• � nornuawaaPoutimPmmrr.a.a ---- ase<mn f � arer. I . ��.-�.-_,,ter �. _ -•:r �•':' ,���`�R�� - wonelswxe�*.d even ... rc s.. vu — — 'tlu rJv a rcua .Y m m rvcsa waa aE >� >.r ru¢ �,.. TREE PROTECT)ON FENCE t �a u TREETREE PLANENC LaJs. � >x iem. P mnc+maxrl � ¢ as •i x rslrr e p a¢r ao s � .I'1eaC K LL>rl.Y P If<lt faEE IIrC 14 P MCiCPa[�.F[ �NOIaar KS.I[1[q Rl �� IAk�I�S �EAk loPia�6i{ym Pta®.aY _ IqQ IIE '.O 9J34 mIR rEt44 K IRral� . Er[ � ewac.osn ePrtom.0 r.rt �s�ac — �:�.. r _ _ �r�. - ruse rmarruE BrewrKs6PKan rvem .MS..KEY1CfW 4arta ri,q tRu W6]ISa.Kmi61[gn.9![EC JCO ]a[Zr 6•x[xf rtlli .4 Nt• l4VLI�lA[Rrq sKrx9l ��.ra 9WJaRWD :wW61F �06fra �160e�M�M __ KlltlmLK¢iu 6 OutF�"4 MI@ , � _••___ ] �rnvamlN plaXlY ao 1IY [1P/EY 4P'ET fr S.lw gflD4i N016 _- !�. wa an.a m�laarx unJ]saM ].�*avP m]�ia.r nti rrmsvmealr crs - Waiw �.x - SHKO-GRCUNDCM PLlWTWG 26oa m1K r6 QLral[ 2 .sra! moax esa lillumgrr,aTr. ry, sae . ,war mwcs nP ti. nrartr m vrsE ro05n[S lie Fr J, asuow Jw, nn p. ! crw m.a arta S aanc[rsnlsaaw.104E an asvla Jrenn aE 4+r0 a !u m,u® w,s ors v x r l mm.a.o .wa Fw. w�i�rurr. aloA e, au�Ew.rx am .t Mil r/lilb. W4,W eiMx 10I Yam[ -�u 4�LL S IG'4Riq . r� A K IgFMG 1®� WASTEINOOSTRIES,LLC DURHAMFACILITY 142STONERARKEOORT -- - I -------- -- �.5 OORHAM,NCz7703 cyu�:cc.armr 116d100 Sr7 Ft. R17 YIM Tj•II1 �1+ / r - _ - \ c ` •.: _ so'Rax.gx _/,}, Yi r ENGINEERS Nana Gt9CrevA.fAY,rtxr / s�,v+ r '� ,Ixxr.x,�,�.,vxcaxnlreAaan iMffl� MAC Paxement area z_� Storage W W t M f of the man lu •,ram - 1RAAryTfN SFA WV shop .% (SQ RFf7�71'a J) �,, / -34000 Stl Fl "' AOAMC xAmf AAp UWZNAWF FAWJY /� _ /IV A9WAII, Y s �, � �t� 1. � ,,. •Y k.� � - i P' 'r! rw m,�,u..v-uY Pave ant Area 7- _ s , t� E ' f Rdlbn hox aM� �I r x` � �'. S s. � I r ..j L 1 r I - < evuoment stw.ye area - s y. +'^i f �`•` i- \\ .1 •� ._ 25.400 Sq Ft. - �� ,yzl�'=,— ✓i _ �" _ P �`c t Y ti : +I _I 1 AM1 SrQf hvYa 1 Lt.+ -� '', 1 / r QECr ARFA- rjE,I.-t ti areas for . `On P+WRTr LW(I1P) , I r waxes mr mervq RgEmwa /r• - T'_AWmI' / -VON EA2 WMr -; 'rTJfa'ec taut J. --' �AaPARWA7f LACS Vi&USPC SW �c� near ra. w.ny vea STNRNRiTFR BASIN a• -'.,.t_-�. ..-� - _(24''+W) 7ffmrrlmST"WAmP"r111111) I rmnr+erwrw+s� -- - /ATznmF 4) LF4[ia511EPldN - - - ��Evelwrea ana for , I Fefrcloth SNlmmer ' - IrutallatSon - ' DISTIN6CONGRIONS Idlfldll�3 i - • • ;I � • .. r�pq K f.S IfIM I At. �~— ez..r 2 51 Waste Industries Stone Park Court Durham, N.C. Estimate cost for paving the existing unpaved areas at the Durham Facility Divide the site into three areas: 1. Main parking area/CNG re -fueling area 2. Truck yard west of the maintenance/office building 3. Yard area west of the scales/ roll -off & trash can storage area Area 1 Unit Cost Extended Cost Area 2. Area 3. 5/11/2016 G. Mills Subgrade Repairs 1 Lump Sum $ 2,500.00 $ 2,500.00 Curb & Gutter 1,380 L. Ft. $ 15.00 $ 20,700.00 Asphalt 116,000 Sq. Ft $ 1.50 $ 174,000.00 Subtotal. $ -197,200.00 Subgrade Repairs 1 Lump Sum $ 2,500.00 $ 2,500.00 Curb & Gutter 785 L. Ft. $ 15.00 $ 11,775.00 Asphalt 34.000 Sq. Ft $ 1.50 $ 51,000.00 Subtotal ' - : $ 65,275.00 Subgrade Repairs 1 Lump Sum $ 2,500.00 $ 2,500.00 Curb & Gutter 980 L. Ft. $ 15.00 , $ 14,700.00 Asphalt 25.400 Sq. Ft $ 1.50 $ 38,100.00 Subtotal $ 55,300.00 Contingency Total, All Areas 15% $ 47,666.25 $ 365,441.25 HAProjects\Durham LCID LandfilllDurham 14-2 (Conceptual STW Design)lCalculationslengineer estimate.xlsx Pavement Estimate N v Scenario 2 Approximate Volume = 271,000 cy Approximate Fill = 4,300 cy ! 4P 3P 0 50 100 154 200 Pickle, Ken From: Don Misenheimer <don@smithgardnerinc.com> Sent: Monday, November 09, 2015 4:05 PM To: Pickle, Ken Subject: RE: Waste Industries, USA - Durham Facilit)(COC# NCG080845 J Tier 3 Notification Thanks so much Ken- Misenheimer SMITH + GARDNER C (919) 815.4315 From: Pickle, Ken [ma iIto: ken. pickle@ncdenr.gov] Sent: Monday, November 09, 2015 4:07 PM To: Don Misenheimer Subject: RE: Waste Industries, USA - Durham Facility COC# NCGO80845 - Tier 3 Notification Hi Don, So, a couple of the elements for Waste Industries are a little out of the box — the Regional Office agreed with your plan, but site conditions did not cooperate; the lag time is unusual because of the Durham review. With those unusual aspects in mind: if you don't mind, please copy me on the follow-up this year with John Holley. I'll file it in our skeleton file up herein the stormwater program so that if future questions arise about why things happened the way they did we will have the info. Thanks, Ken From: Don Misenheimer[mailto:don@smithgardnerinc.comj Sent: Monday, November 09, 2015 3:50 PM To: Pickle, Ken <ken.pickle@ncdenr.gov> Subject: Fwd: Waste Industries, USA - Durham Facility COC# NCGO80845 - Tier 3 Notification ---------- Forwarded message ---------- From: Don Misenheimer <don@smithgardnerinc.com> Date: Fri, Jul 18, 2014 at 2:03 PM Subject: Waste Industries, USA - Durham Facility COC# NCG080845 - Tier 3 Notification To: john.holley@ncdenr.gov Mr. Holley- Per our conversations this morning, please find the attached Tier 3 notification letter for the Waste Industries, USA - Durham Facility, COC# NCG080845. As discussed, this letter outlines the current conditions on -site, as well as, previous measures taken on -site to address TSS. This letter also puts forward the site's plan to install on -site storage for stormwater. Please contact me with any questions or comments you may have. We have also delivered a hard copy of this letter to Central Files. Best Regards - Don M. Misenheimer Project Scientist SMITH + GARDNER 14 N. Boylan Avenue Raleigh, NC 27603 P (919) 828.0577 ext. 224 C (919) 815.4315 www.smithgardnerinc.com Don M. Misenheimer Project Scientist SMITH + GARDNER 14 N. Boylan Avenue Raleigh, NC 27603 P (919) 828.0577 x224 F (919) 828.3899 C (919) 815.4315 Pickle, Ken From: Don Misenheimer <don@smithgardnerinc.com> Sent: Monday, November 09, 2015 433 PM To: Holley, John Cc: Bill Davidson; Pickle, Ken Subject: NCG080845 Waste Industries LLC, Durham - Tier 3 Update Attachments: NCGO80845 _Tier 3 Update letter.pdf Mr. Holley, Please find an update on the Tier 3 status of the above mentioned site. Please let us know any questions or comments - Don M. Misenheimer Project Scientist SMITH + GARDNER 14 N. Boylan Avenue Raleigh, NC 27603 P (919) 828.0577 c (919) 815.4315 www.smithgardnerinc.com SMITMARDNER ENGINEERS November 9, 2015 Mr. John Holley, P.E. ABNESS rr! WES 14 N. BuylanAvenue. Ucigh NC27503 919.928.9577 www.smithgardnerinc.corn Regional Engineer Division of Energy, Minerals and Land Resources - 1628 Mail Service Center Raleigh, NC 27699 RE: Tier 3 — Status Update Waste Industries, LLC — Durham Certificate of Coverage #NC6080845 General Permit#NCG080000 Dear Mr. Holley. Smith Gardner Inc. (S+G) has prepared this status update to the Division of Energy, Minerals and Land Resources - Stormwater Permitting Program to inform you of the current status of the planned improvements (basin installation) at the facility. CURRENT NPOES PERMIT STATUS In August 2012, the City of Durham required the facility to begin conducting monthly monitoring of site stormwater due to high levels of TSS leaving the site. In December 2013, the facility officially entered Tier 2 status (NPDES General Permit for Transit and Transportation) after twice exceeding the TSS benchmark value of 100mg/l. After the February 2014 monitoring even, the facility entered Tier 3 status for TSS and official notification to the division was made in July 2014, including the plan for the installation of a stormwater detention basin on -site (attached). ANALYTICAL MONITORING RESULTS (2012-October 2015) DATE TSS (Benchmark=100) Non -Polar Oil G Grease (Benchmark=15) May 2012 855 D September 2012 19.6 0 Februa 2013 11 VB October2013 2Bo 13 November 2013 Soo 813 December 2013 171 <5 February 2014 712 0 May 2014 424 14.7 December 2014 980 <5 March 2015 536 0 October 2015 36.5 0 Mr. John Holley, P.E. November 9, 2015 Page 2 of 2 CURRENT PROJECT STATUS Subsequent to the notification to the Division of Tier 3 status, S+G began the City/County of Durham submittal process for approval of the basin (requiring a Level 3 Site plan). The process took eight 18) months and approval was granted on March 31, 2015. Construction was slotted to begin during the fall of the year. Pre -construction activities including surveys, bid procurement, and further site investigation was performed in the interim. During an investigation on -site, bedrock was determined to be from 3-7 feet in areas of the proposed basin. It was determined that the originally proposed location for the basin would not be suitable for purpose of the design. Waste Industries has purchased the property to the south of the facility ILot 4 shown on Figure 1 of the attached Notification Letter). Conservative preliminary estimates show this tot as a suitable new location for the proposed basin. A site evaluation is currently being performed including wetland and stream investigation, depth to rock and required basin size. After the current evaluation is complete, S+G will meet with the Durham City -County Planning Department to discuss the project under the current approval. S+G will update this Division with the outcome of that meeting. Please contact me by phone (919- 828-0577, ext. 224) or by email below with any questions or comments. Sincerely, Smith Gardne I e. ram' Don M. isenheimer Project Scientist, ext. 224 donfdsmithgardnerinc.com dram Attachment Cc. Mr. Bill Davidson, Waste Industries Mr. John Pfleger, Waste Industries Mr. James Azarelo, City of Durham File H:IProjectslDurham LCID LandfittlDURHAM 12-1 INPDES MonitoringkMonitoring Reports120151Tier 3 Update tetter.docx SMITH+6ARDNER ENG1NfER5 July 18, 2014 Mr. John Holley, P.E. ADDRESS TEE WEB 14 N. Bcylan Avenue, Raleigh NC 27603 919.626.0577 wwwsmilhgaidnOrin c.com Regional Engineer Division of Energy, Minerals and Land Resources - 1628 Mail Service Center Raleigh, NC 27699 RE: Tier 3 Notification Waste Industries, USA — Durham Facility Certificate of Coverage #NC6080845 General Permit #NCG080000 Dear Mr. Holley: Smith Gardner Inc. (S+G) has prepared this official notification to the Division of Energy, Minerals and Land Resources - Stormwater Permitting Program to inform you that the Waste Industries, USA - Durham Facility (COC#NCG080845) has entered a Tier 3 Status. CURRENT NPOES PERMIT STATUS In August 2012, the City of Durham required the Facility to begin conducting monthly monitoring of site stormwater due to high levels of TSS leaving the site. In December2013, the facility officially entered Tier 2 status (NPDES General Permit for Transit and Transportation] after twice exceeding the TSS benchmark value of 100mg11. As of February 2013, the Durham Facility has entered Tier 3 status due to four (4) exceedences over the TSS benchmark value. ANALYTICAL MONITORING RESULTS (2012-2014) DATE TSS (Benchmark=100) Non -Polar Dil B Grease (Benchmark=15) May 21312 855 D September 2012 19.6 0 FebruVj 2013 11 4.78 DCtober 2013 280 13 November 2013 500 8.73 0ecernber2013 171 <5 Februa 2014 712 0 May 2014 424 14.7 ON -GOING SITE IMPROVEMENT STATUS Several low-cost options have been implemented at the site to attempt to reduce the TSS Levels at the site. These options have only shown limited improvement in levels of TSS Leaving the site. The large volume of run-off, due to impervious surfaces and drainage area size, appears to be "over -powering" these installed options. Below is a list of several improvements that have been used on -site since August 2012: Mr. John Holley, P.E. July 18, 2014 Page 2 of 4 • Re -grading the parking lot near the drop -inlet; • Placing sediment collection bags in the drop-intets; Installing new aggregate with fabric at selected areas of parking lot; + Installing rip -rap channels in high flow areas; • Installing check -dam; • Placing coir-fiber wattles in channels; and • Moving the outfall monitoring location to the associated stormwater easement associated with the site. In April 2014, S+G took part in a conference call with Waste Industries to discuss additional options to address TSS leaving the site. It was decided that S+G would perform conceptual stormwater modeling and design work to explore the options of on -site storage at the facility, including the analysis of pre- and post -development stormwater discharges from the site outfall. S+G was also tasked with reviewing City and County Ordinances, as well as, meeting with the City/County to discuss any additional requirements/fees/submittals that may be warranted for implementation of the conceptual design. STORMWATER MODELING AND CONCEPTUAL DESIGN S+G conducted site visits in April and June 2014 to verify the existing conditions to serve as inputs for a HydroCAD model. Culvert sizes, as included in the as -built', were field checked for accuracy while existing grates and drop inlet depths were measured. S+G determined that enough valid information was present to proceed with a HydroCAD model in the design process. One initial design investigated was for a small basin to be constructed in an area on the eastern portion of the property that is currently used for storing plastic trash/recycling bins. However, this initially designed basin would have insignificant storage and therefore not be effective in removing sediment. Other ideas, such as stormwater control wetlands were considered, but not enough land was available. The idea of paving the parking lots was also explored, but rejected due to the expense and the slight increase in the peak discharge that would be expected. The most practical method to prevent future sediment from leaving the site is to build a stormwater basin (basin) near the current discharge point. S+G elected to design a basin that would hold nearly all of the run-off from a 10-year, 24-hour storm event. Because the basin would be a permanent feature, the basin was also designed to route a 100-year, 24- hour storm event without overtopping the banks. The proposed design creates the maximum storage and retention time possible without relocating the permitted discharge point. ' Waste Industries Durham District Campus - Phase One District Office and Truck Terminal. Dated June 1997, by Sungate Design Group, P.A. Mr. John Holley, P.E. July 18, 2014 Page 3 of 4 Stormwater Basin Design Information The basin has a drainage area of approximately 15 acres. Most of the drainage area (approximately 14 acres) is gravel parking area, access roads, or buildings. The basin is designed to be constructed in the wooded area north of Stone Park Court (as shown on the attached Figure 1). No excavation is proposed to impinge on the rights of ways of the sewer easement or on the natural gas easement. The total depth of the basin is shown to be excavated to eight (8) feet to the crest, but the western sides will have longer slopes. The side slopes will be at 2.5H:1V. The proposed basin will discharge through existing 18-inch diameter RCP culvert that runs under Stone Park Court. The existing culvert will be extended as necessary to connect to a new 4'x4'x6' concrete riser (Figure 2 attached). A Faircloth skimmer will be installed at the base of the concrete box. The top rim of the box will be approximately six (61 feet above the invert of the existing culvert. The rim of the box will function as the principal spillway for the basin, creating a surface area of approximately 0.75 acres at the rim elevation. A grass -lined, emergency spillway is proposed to be constructed in existing ground (approximately 1-foot higher than the top of the concrete box). Any flow from the emergency spillway will discharge directly to the property (also owned by Waste Industries) south of the facility; however, no flow is expected in the emergency spillway in a 100-year storm event. The proposed basin design will significantly reduce the discharge from the site, as shown on Chart 1. Most storm events will discharge entirely through the Faircloth skimmer at a constant rate of approximately 0.2 cubic feet per second (CFSI. Larger storm events will pass over the rim of the principal spillway. For example, in a 10- year, 24-hour storm event (i.e., 5.01 inches of precipitation in 24 hours), the existing conditions are calculated to generate a peak discharge of approximately 97 CFS. With proposed basin, the same storm event would discharge less than 2 CFS. In a 25- year, 24-hour storm event (5.93 inches or rain), the peak discharge is reduced from 118 CFS to 6 CFS. Reducing the peak discharge and storing water in the basin will allow sediment to settle before the water leaves the site. During a 25 year storm event, the calculated settling efficiency of the basin is more than 95%. PERMITTING AND ZONING REVIEW (CITY/COUNTY OF DURHAM) In June 2014, S+G met with the City of Durham (Planning/Zoning Department and Stormwater Services) and Durham County (Engineering) to discuss the conceptual design. Fees, submittals, and other requirements that would be foreseeable were discussed during these informal meetings. The results of which are discussed below. To construct the proposed basin, a Level 3 Site Plan will need to be submitted to the City of Durham Planning Department. Subsequently, this plan will be reviewed by other City departments including Stormwater Services. This Site Plan will include: Mr. John Holley, P.E. July 18, 2014 Page 4 of 4 • a letter report presenting the design summary and associated calculations; • nutrient loading calculations (post vs pre development conditionsl; • a drawing set; and • an erosion and sedimentation control (E&SC) plan Simultaneously, the E&SC plan will be submitted to Durham County Engineering which will start a 30-day "timer" to begin construction. CURRENT PROJECT STATUS Currently, the design is being reviewed and finalized as preparation for submittal to the City and County of Durham, for approval. Waste Industries continues to be pro -active in addressing these stormwater issues present on -site. S+G will notify the Regional Administrator as the design is finalized, subsequently approved, and constructed. Timeline The City Planning Department will take up to 30 days from day of submission to respond. Most likely there wit( be one round of comments followed by another 30 days for Planning to respond. Subsequently final submittal copies of the plans wilt be submitted for Planning to issue a final approval. S+G estimates this process to take 2-3 months. The submittal to County Engineering turnaround should be fairly quick, approximately 30 days. Please note that these items are submitted simultaneously. Construction time may take up to a month. Overall. S+G estimates a timetine of 5-6 months until project completion. S+G wit[ provide an updated timeline as this project proceeds. Please contact me by phone (919- 828-0577, ext. 224) or by email below with any questions or comments. Sincerely, Smith Uardne l Don M. isenheimer Project Scientist, ext. 224 donfasmithgardnerinc.com dmm Attachment Cc. Mr. John Pfleger, Waste Industries File C:\Usersldonmisenheimer\Desktop120141notification tetter.dou Y •.� 1 f f y� __ _p--��� .mow __ �x^'. >allS_• ` _ .._ - _ `_ . -.. W. Bow AS1E i ' • �' �` �i '� SEER S7 t✓'`� n► D INS �N 1 Is `• , n �* E h LOT 1 �r, /i.�: �y �,�•� rrr - yy 7v 1` E,-5ttKMW11115KCPAW PH 155 PC a PRO?OSE�, s '`'r:.rf!• yl+•. _ ,/r ` ;'i r Wd AND - BASIN -SUE HOUSE ���%. � r"�Y,` ! ;': � � "$GALES , � '�,� »....:� _ .• �-.f,���. - • ^'r J ,^-ter � 1 � _ __ vb - - 1 -\` - \ - \ \: � y /` lib PG fJ IWFr r: ,�_ '.:.n-�:,1�:,;r<. _t.•'..- i= $TEi'.1&rrflL4AA. �P3171W]847'., �•� _ { R`\ LE6'i1D _ _ j r —� - :. { PGILVE4iT; • Bow AO'410 =memol4F 1) flok. L TEC}N} — --_ ea2olcs cnnow+l?9M 0 rr,f.,• in- ldOGNIEIIN _ , � Lj i • � f '10F_R6Y!'Ig61r!!L P ! - �. �/. _ r cwm },!` , I `'''�¢]il[pOAD PJ9! ` _ _- Ti,' -Pfl"OIIb=43•'ilo-"iSt4- // �, �-' _ — • A9 1/ P6 4S . �' _ x! r$' ` , '� APPRIWIE Rll%'M IAE (K 1E%E1t a WIN NO 1 UI }.: 5.��- . •.^ cWiwr FIGURE 'I, — — — — WOM DURHAM AMIN. &_. MAINTENANCE FACILTY —GAS— E>dAICgSAliGIE PROPOSED BASIN scold a Gull IIET '17 (SEE MI v N JPer Ci�lE mP 24•� CAST � A FL= —375.5 ONx1.*uOFM(4 EL=-•374 PREOASE 'COEIE Bm .•• (91 MOTE ) IM DIAM. RCP EXTEND EXISTING Ott FOR 9MlQt -+ CULVERT AS (SIZE AS MAW FOR � � ` NECESSARY TO ALLOW INSTALLATION OF THE RISER EL=-386.1 EL=-368 EL= —367.5 a CONaETE FILL (um TOYFo WART OUQ Ist IIEIEOIM aOIIOETE BASE (SE NOTE 4) OOIpwo OBII5 a TIM BEI2fa1G SWU A -A FIGURE 2: CONCRETE RISER o 1. YG1TLTiBIi1E daMEs ON AL PFIT6. 2. PRECAST o01 xm DIM %wL OOIFm TO w FOLwm mulmo l4 A. 0110 IE: 02IFFFisI1E STNO M 4M PS B. 83ONM ON A-M5. WAGE 60 G MM H-M LOAM 3. MM SEPS FM OW MM WN Ib� 9M %MM NAVE A tr,- SPAI MG TIE ML NOR1E ff M ww Ka START FREE 51EP E! mm TOP. 4: BASE M BE PHY9GLLr ATEAM M tE1FI MIM KM 11E BFSRI OF TIE II H SIOBCRIiE. CHARTI: ADMINISTRATIVE AND MAINTENANCE FACILITY EXISTING v. PROPOSED DISCHARGE 160 140 II �34120 — _/0�7 cm ;ro III IIIIIi iIII 1 II 40 20 o as 50 75 goo YFAAX Of i4.N011Ap IW1S1 AMEVENT NM 151 36 —4—Existing Proposed -A SMITH#GARDNfR INGINIIRS — �TMr s TR s!;t3 14 K Boylan avenue, Raleigh NC 27602 919,828.0577 mjv:,.smi[hyidnerimarri July 18, 2014 Mr. John Holley, P.E. Regional Engineer Division of Energy, Minerals and Land Resources - 1628 Mail Service Center Raleigh, NC 27699 RE: Tier 3 Notification Waste Industries, USA — Durham Facility Certificate of Coverage #NC6080845 General Permit #N CG080000 Dear Mr. Holley: RECEIVED JUL 18 2014 CENTRAL FILES DWa/BOG Smith Gardner Inc. (S+G) has prepared this official notification to the Division of Energy, Minerals and Land Resources - Stormwater Permitting Program to inform you that the Waste Industries, USA - Durham Facility (COC#NCG0808451 has entered a Tier 3 Status. CURRENT NPOES PERMIT STATUS In August 2012, the City of Durham required the Facility to begin conducting monthly monitoring of site stormwater due to high levels of TSS leaving the site. In December2013, the facility officially entered Tier 2 status (NPDES General Permit for Transit and Transportation) after twice exceeding the TSS benchmark value of 100mg/l. As of February 2013, the -Durham Facility has entered Tier 3 status due to four (4) exceedences over the TSS benchmark value. ANALYTICAL MONITORING RESULTS (2012-2014) BATE TSS (Benchmark=100) Non -Polar Oil 6 Grease (Benchmark=15) May 2012 855 0 September 2012 19.6 0 February 2013 11 08 October 2013 280 13 November 2013 500 8.73 Oecember 2013 171 <5 February 2014 ?12 1 0 May 2014 424 1 14.E ON -GOING SITE IMPROVEMENT STATUS Several low-cost options have been implemented at the site to attempt to reduce the TSS Levels at the site. These options have only shown limited improvement in levels of TSS Leaving the site. The large volume of run-off, due to impervious surfaces and drainage area size, appears to be "over -powering" these installed options. Below is a list of several improvements that have been used on -site since August 2012: 40 _. Mr. John Hotley, P.E. July 18, 2014 Page 2 of 4 • Re -grading the parking lot near the drop -inlet; • Placing sediment collection bags in the drop -inlets; • Installing new aggregate with fabric at selected areas of parking lot; • Installing rip -rap channels in high flow areas; • Installing check -dam; • Placing coir-fiber wattles in channels; and • Moving the outfall monitoring location to the associated stormwater easement associated with the site. In April 2014, S+G took part in a conference call with Waste Industries to discuss additional options to address TSS leaving the site. It was decided that S+G would perform conceptual stormwater modeling and design work to explore the options of on -site storage at the facility, including the analysis of pre- and post -development stormwater discharges from the site outfall. S+G was also tasked with reviewing City and County Ordinances, as well as, meeting with the City/County to discuss any additional requirements/fees/submittals that may be warranted for implementation of the conceptual design. STORMWATER MODELING AND CONCEPTUAL DESIGN S+G conducted site visits in April and June 2014 to verify the existing conditions to serve as inputs for a HydroCAD model. Culvert sizes, as included in the as -built', were field checked for accuracy while existing grates and drop inlet depths were measured. S+G determined that enough valid information was present to proceed with a HydroCAD model in the design process. One initial design investigated was for a small basin to be constructed in an area on the eastern portion of the property that is currently used for storing plastic trash/recycling bins. However, this initially designed basin would have insignificant storage and therefore not be effective in removing sediment. Other ideas, such as stormwater control wetlands.were considered, but not enough land was available. The idea of paving the parking lots was also explored, but rejected due to the expense and the slight increase in the peak discharge that would be expected. The most practical method to prevent future sediment from leaving the site is to build a stormwater basin (basin) near the current discharge point. S+G elected to design a basin that would hold nearly all of the run-off from a 10-year, 24-hour storm event. Because the basin would be a permanent feature, the basin was also designed to route a 100-year, 24- hour storm event without overtopping the banks. The „proposed design creates the maximum storage and retention time possible without relocating the permitted discharge point. Waste Industries Durham District Campus - Phase One District Office and Truck Terminal. Dated June 1997, by Sungate Design Group, P.A. Mr. John Holley, P.E. Juty 18, 2014 Page 3 of 4 Stormwater Basin Design information The basin has a drainage area of approximately 15 acres. Most of the drainage area (approximately 14 acres) is gravel parking area, access roads, or buildings. The basin is designed to be constructed in the wooded area north of Stone Park Court (as shown on the attached Figure 11. No excavation is proposed to impinge on the rights of ways of the sewer easement or on the natural gas easement. The total depth of the basin is shown to be excavated to eight (8) feet to the crest, but the western sides will have longer slopes. The side slopes will be at 2.5H:lV. The proposed basin will discharge through existing 18-inch diameter RCP culvert that runs under Stone Park Court. The existing culvert will be extended as necessary to connect to a new 4'x4'x6' concrete riser (Figure 2 attached). A Faircloth skimmer will be installed at the base of the concrete box. The top rim of the box will be approximately six (6) feet above the invert of the existing culvert. The rim of the box will function as the principal spillway for the basin, creating a surface area of approximately 0.75 acres at the rim elevation. A grass -lined, emergency spillway is proposed to be constructed in existing ground (approximately 1-foot higher than the top of the concrete box). Any flow from the emergency spillway will discharge directly to the property (also owned by Waste Industries) south of the facility; however, no flow is expected in the emergency spillway in a 100-year storm event. The proposed basin design will significantly reduce the discharge from the site, as shown on Chart 1. Most storm events will discharge entirely through the Faircloth skimmer at a constant rate of approximately 0.2 cubic feet per second (CFS). Larger storm events will pass over the rim of the principal spillway. For example, in a 10- year, 24-hour storm event (i.e., 5.01 inches of precipitation in 24 hours), the existing conditions are calculated to generate a peak discharge of approximately 97 CFS. With proposed basin, the same storm event would discharge less than 2 CFS. In a 25- year, 24-hour storm event (5.93 inches or rain), the peak discharge is reduced from 118 CFS to 6 CFS. Reducing the peak discharge and storing water in the basin will allow sediment to settle before the water leaves the site. During a 25 year storm event, the calculated settling efficiency of the basin is more than 95%. PERMITTING AND ZONING REVIEW (CITY/COUNTY OF DURHAM) In June 2014, S+G met with the City of Durham (Planning/Zoning Department and Stormwater Services) and Durham County (Engineering) to discuss the conceptual design. Fees, submittals, and other requirements that would be foreseeable were discussed during these informal meetings. The results of which are discussed below. To construct the proposed basin, a Level 3 Site Plan will need to be submitted to the City of Durham Planning Department. Subsequently, this plan wilt be reviewed by other City departments including Stormwater Services. This Site Plan will include: Mr. John Hottey, P.E. July 18, 2014 Page 4 of 4 • a letter report presenting the design summary and associated calculations; • nutrient loading calculations (post vs pre development conditionsl; • a drawing set; and • an erosion and sedimentation control (E&SC) plan Simultaneously, the E&SC plan will be submitted to Durham County Engineering which will start a 30-day "timer" to begin construction. CURRENT PROJECT STATUS Currently, the design is being reviewed and finalized as preparation for submittal to the City and County of Durham, for approval. Waste Industries continues to be pro -active in addressing these stormwater issues present on -site. S+G will notify the Regional Administrator as the design is finalized, subsequently approved, and constructed. Timeline The City Planning Department will take up to 30 days from day of submission to respond. Most likely there will be one round of comments followed by another 30 days for Planning to respond. Subsequently final submittal copies of the plans witt be submitted for Planning to issue a final approval. S+G estimates this process to take 2-3 months. The submittal to County Engineering turnaround should be fairly quick, approximately 30 days. Please note that these items are submitted simultaneously. Construction time may take up to a month. Overall, S+G estimates a timeline of 5-6 months until project completion. S+G will provide an updated timeline as this project proceeds. Please contact me by phone (919- 828-0577, ext. 224) or by email below with any questions or comments. Sincerely, Smith Gardne I Don M. isenheimer Project Scientist, ext. 224 donfasmithgardnerinc.com dmm Attachment Cc. Mr. John Pfleger, Waste Industries File CaUsersldonmisenheimer\Desktop120341notification letter.docx R '° 'YOw". i. /f-; '•;l;h- :--ram. �. '�- •—.r—_'—�T;.;-�e':�.�� - k .—�.:--r^_ `" " _ . E,V5FA1'C '' : i•- r�. � o`,I cl . ell i . - r.�.�'/'�_ ��''.,- • � - ' ' f�`'. p5 oS SFa 5 .� .�;, ; r'•� �, IN.S it s I ; ►j1 ' �, AIN N �14, LOT t _•S_* f _ -fir" %. 4. ,�'!-"��•f /"! OUTY it l�il SIQER01hpo MPr 19 IW5iCALPoUX r ' "� Or' �rNi` 1 r ' PN omo-6 3$-4m A PROPOSED�� �! ~ 'S• ' f AND / BASIN ".� f�. '� _ � " SCALES � !�..•,.. "Y �'' � 1 I .5..,; �v '"� ^'` .I - _ _ l •" t • 6, .'K ' n 100 F'T -tM PROPOSED ., ,,,.••- •- ; ' ' t � +` RA (16p-0}.'F �-� ` r ~ , t• — �� SI'UE FWD IQbWL i. ;1 i. .; -_ _: " ..: E USTI�.18jlbIAM. 6 Ulm r ^r::T; _'S-• P GLei VE pejeeo-Cs�y 4 - — ••�;-� BMW COYIGFIP lsff guff 1) %i '.", t F OX. LA ATibN) . r ,; !� •- �3 ;• .:310E�AD l4iA�, :f P i .•':, } • r� F70--! PR9Pfi�D 1U ORfIQM ,• ;���;`}A•:•- �:� $j� "K Rw a .,',�' �`�' If :•,.PtL1i5.P014'... LP1Plt �I --- PImPmxowm aF9 PC APPRa0 m PRpi m LK ( 4fFeem 2) COWANr FIGURE 1. _ Q DURHAM AMIN. & MAINTE14ANCE FACILTY PROPOSE© BASIN s'm mm QUM Kv SEE N01E STEP' (SEE MOTE 3 PLM 2rO CAST IRM A T PRAIF & cm it -375.5 _ 4'v X 1. "u OTC (4 SIMS)- EL¢ -374 ..ly CRFKE FM Saw (SITE AS MOA B FOR SIOIIM ELm `368.1 EL=-368 EL= -367.5 r ---� r �- CONCRETE FLL (SLOPED TWO MVERT MM rxr REWO M Ca KIRETE t>ASE (SEE NW 4) CI PACIED CRIi9@ SM EIME SEC1tON A —A FIGURE 2: CONCRETE RISER PRTTAST CQHf m Tar PRECAST MAKE BOX (SEE NOIE2) 18" DIAM. RCP EXTEND EXISTING CULVERT AS NECESSARY TO ALLOW INSTALLATION OF/THE RISER Ti{ 1p t!� I PRDMDE WATEiMIT JMITS DN ALL PRK i PRECAST MOM BaXES 9*1 CaFM TO THE FOUD" WJMABB - A. CONCRM- CMFRESW STREIM 4WD P9 B. REIFORMQ ASIM "5. WAX ED C. BETS H-20 LOAM 3. PRDYME STEPS FOR DRIP KM MM H>" STEPS STALL HAVE A IC SPACM THE RILL HET9TT OF ME DROP MLET_ START MIST STEP r MM TOP. 4. BASE MIST BE PHISTCAiLY ATTA08 OR MMMIED MTO IW tEM OF THE R1SEIi SIR1I IURE. CHART 1: ADMINISTRATIVE AND MAINTENANCE FACILITY EXISTING v. PROPOSED DISCHARGE 160 151 140 134 120 118 ! I 100 97 LAJ LA- 80 y ; Existing yI —11rProposed 60 v I I 40 I I I 36 20 j I 2 6 1 0 0 25 50 75 100 YEAR RETURN OF 24-HOUR NOAA STORM EVENT SMITMARONER ENGINEERS July 18, 2014 Mr. John Holley, P.E. I00RES5 In. WEB 14 N. Boylan Avenue, Raleigh NE 27603 919.826.0577 www.smlinga(dnerinc.com Regional Engineer Division of Energy, Minerals and Land Resources - 1628 Mail Service Center Raleigh, NC 27699 RE: Tier 3 Notification Waste Industries, USA— Durham Facility Certificate of Coverage #NCG080845 General Permit #NC6080000 Dear Mr. Holley: Smith Gardner Inc. (S+GI has prepared this official notification to the Division of Energy, Minerals and Land Resources - Stormwater Permitting Program to inform you that the Waste Industries, USA - Durham Facility ICCC#NCG080845) has entered a Tier 3 Status. CURRENT NPDES PERMIT STATUS In August 2012, the City of Durham required the Facility to begin conducting monthly monitoring of site stormwater due to high levels of TSS leaving the site. In December2013, the facility officially entered Tier 2 status (NPDES General Permit for Transit and Transportation) after twice exceeding the TSS benchmark value of 100mg/l. As of February 2013, the Durham Facility has entered Tier 3 status due to four (4) exceedences over the TSS benchmark value. ANALYTICAL MONITORING RESULTS (2012-2014) DATE TSS (Benchmark=100) Non -Polar H 6 Grease (13enchmark=15) May 2012 855 0 September 2012 19.6 0 Februa 2013 11 4.78 October 2013 28D 13 November 2013 50D 8.73 December 2013 171 <5 Februa 2014 712 0 May 2014 424 14.7 ON -GOING SITE IMPROVEMENT STATUS Several low-cost options have been implemented at the site to attempt to reduce the TSS levels at the site. These options have only shown limited improvement in levels of TSS Leaving the site. The large volume of run-off, due to impervious surfaces and drainage area size, appears to be "over -powering" these installed options. Below is a list of several improvements that have been used on -site since August 2012: Mr. John Holley, P.E. July 18, 2014 Page 2 of 4 • Re -grading the parking lot near the drop -inlet; • Placing sediment collection bags in the drop -inlets; • Installing new aggregate with fabric at selected areas of parking tot; • Installing rip -rap channels in high flow areas; • Installing check -dam; • Placing coir-fiber wattles in channels; and • Moving the outfall monitoring location to the associated stormwater easement associated with the site. In April 2014, S+G took part in a conference call with Waste Industries to discuss additional options to address TSS leaving the site. It was decided that S+G would perform conceptual stormwater modeling and design work to explore the options of on -site storage at the facility, including the analysis of pre- and post -development stormwater discharges from the site outfall. S+G was also tasked with reviewing City and County Ordinances, as well as, meeting with the City/County to discuss any additional requirements/fees/submittals that may be warranted for implementation of the conceptual design. STORMWATER MODELING AND CONCEPTUAL DESIGN S+G conducted site visits in April and June 2014 to verify the existing conditions to serve as inputs for a HydroCAD model. Culvert sizes, as included in the as -built'; were field checked for accuracy while existing grates and drop inlet depths were measured. S+G determined that enough valid information was present to proceed with a HydroCAD model in the design process. One initial design investigated was for a small basin to be constructed in an area on the eastern portion of the property that is currently used for storing plastic trash/recycling bins. However, this initially designed basin would have insignificant storage and therefore not be effective in removing sediment. Other ideas, such as stormwater control wetlands were considered, but not enough land was available. The idea of paving the parking lots was also explored, but rejected due to the expense and the slight increase in the peak discharge that would be expected. The most practical method to prevent future sediment from leaving the site is to build a stormwater basin (basin) near the current discharge point. S+G elected to design a basin that would hold nearly all of the run-off from a 10-year, 24-hour storm event. Because the basin would be a permanent feature, the basin was also designed to route a 100-year, 24- hour storm event without overtopping the banks. The proposed design creates the maximum storage and retention time possible without relocating the permitted discharge point. ' Waste Industries Durham District Campus - Phase One District Office and Truck Terminal. Dated June 1997, by Sungate Design Group, P.A. Mr. John Holley, P.E. July 18, 2014 Page 3 of 4 Stormwater Basin Design Information The basin has a drainage area of approximately 15 acres. Most of the drainage area (approximately 14 acres) is gravel parking area, access roads, or buildings. The basin is designed to be constructed in the wooded area north of Stone Park Court (as shown on the attached Figure 11. No excavation is proposed to impinge on the rights of ways of the sewer easement or on the natural gas easement. The total depth of the basin is shown to be excavated to eight (8) feet to the crest, but the western sides will have longer slopes. The side slopes will be at 2.5HAV. The proposed basin will discharge through existing 18-inch diameter RCP culvert that runs under Stone Park Court. The existing culvert will be extended as necessary to connect to a new 4'x4'x6' concrete riser (Figure 2 attached). A Faircloth skimmer will be installed at the base of the concrete box. The top rim of the box will be approximately six (6) feet above the invert of the existing culvert. The rim of the box will function as the principal spillway for the basin, creating a surface area of approximately 0.75 acres at the rim elevation. A grass -lined, emergency spillway is proposed to be constructed in existing ground (approximately 1-foot higher than the top of the concrete box). Any flow from the emergency spillway will discharge directly to the property (also owned by Waste Industries) south of the facility; however, no flow is expected in the emergency spillway in a 100-year storm event. The proposed basin design will significantly reduce the discharge from the site, as shown on Chart 1. Most storm events will discharge entirely through the Faircloth skimmer at a constant rate of approximately 0.2 cubic feet per second ICFS). Larger storm events will pass over the rim of the principal spillway. For example, in a 10- year, 24-hour storm event (i.e., 5.01 inches of precipitation in 24 hours), the existing conditions are calculated to generate a peak discharge of approximately 97 CFS. With proposed basin, the same storm event would discharge less than 2 CFS. In a 25- year, 24-hour storm event (5.93 inches or rain), the peak discharge is reduced from 118 CFS to 6 CFS. Reducing the peak discharge and storing water in the basin will allow sediment to settle before the water leaves the site. During a 25 year storm event, the calculated settling efficiency of the basin is more than 95%. PERMITTING AND ZONING REVIEW (CITY/COUNTY OF DURHAM) In June 2014, S+G met with the City of Durham (Planning/Zoning Department and Stormwater Services) and Durham County (Engineering) to discuss the conceptual design, Fees, submittals, and other requirements that would be foreseeable were discussed during these informal meetings. The results of which are discussed below. To construct the proposed basin, a Level 3 Site Plan will need to be submitted to the City of Durham Planning Department. Subsequently, this plan will be reviewed by other City departments including Stormwater Services. This Site Plan will include: Mr. John Holley, P.E. July 18, 2014 Page 4 of 4 • a letter report presenting the design summary and associated calculations; • nutrient loading calculations [post vs pre development conditions); • a drawing set; and • an erosion and sedimentation control (E&SC) plan Simultaneously, the E&SC plan will be submitted to Durham County Engineering which will start a 30-day "timer" to begin construction. CURRENT PROJECT STATUS Currently, the design is being reviewed and finalized as preparation for submittal to the City and County of Durham, for approval. Waste Industries continues to be pro -active in addressing these stormwater issues present on -site. S+G will notify the Regional Administrator as the design is finalized, subsequently approved, and constructed. Timeline The City Planning Department will take up to 30 days from day of submission to respond. Most likely there will be one round of comments followed by another 30 days for Planning to respond. Subsequently final submittal copies of the plans will be submitted for Planning to issue a final approval. S+G estimates this process to take 2-3 months. The submittal to County Engineering turnaround should be fairly quick, approximately 30 days; Please note that these items are submitted simultaneously_. Construction time may take up to a month. Overall, S+G estimates a timeline of 5-6 months until project completion. S+G will provide an updated timeline as this project proceeds. Please contact me by phone (919- 828-0577, ext. 2241 or by email below with any questions or comments. Sincerely, Smith Gardne I Don M. isenheimer Project Scientist, ext. 224 donldsmithgardnerinc.com dram Attachment Cc. Mr. John PReger, Waste Industries File C:1UsersldonmisenheimerlDesktcp120141notiflcation tetter.docx ~ ,4•_" �. '�. ;,f �yrr. �ti` __ _ "--a--�^�- _ _ '. =��^ _ ""_:_' • __ _ ' ' e�,r,` if • - -`_"'.ir• OPP �'�.• ^`�� .'g`,+SJ:� �f- _ ,,,..1'•'K_ .•fit �.'�r I �ij''' N iMp..' F. .y.�'- ram. ;;:moo::?j*'I - •! ! ' i ASTE ' SFER ST INNS TI } I►. D AN N `, icy ;I>� a .' LOT 1 ANDy�� CIUTY +j, J �; : 1% .'srt1E PPM FlcusAEFL Pux �„�i A PROPpSED BASIN xkEs y . •� .,•� s HT: Zr 7- N-7— in 5101E Kosa�k Pw a PROPOSED•\ : 1e0FT �' �� 'INGND- -UN RISER �'I % r~ :'fir. ^'.L /-�!!''"• ..r� J '� ' Y FM 10JU IPAN STIMF.78UTAM. �FBf PC71 .\LEM .•�' •r'. fey�. =:,. x;R.. - }} �`,�, I ia671ACYGf7lIOIRI�EfJ T4. Y�tl61�1P r FE �:�� „C ; � I � ••� :`-1!6,fE M to", �• � ` - r' FIA64D Y Cf11101R �! JI �',"xwo PAII _ - `•li.. a ,PII,UEIa iC:r �� Y• - - _ —._ _ (F,E Y} .:a�: _ - M1 -.._, r r ` - 1 �IPP1l�7iAlE Pf�4NY1r UE 1E3il�Rf ,r r"�!: �• �•rIPIFlR1 %J--�— _ ,�r•£��+'�-,c-�::".'.' __ � � ,- ` --- 1Jlf:Y1KA MOPE NE 1q Fnw ms OK M" tm i,'. .'�' ` •.� - - COMPANY ' FIGURE i. DURHAM AMIN. & _ , _ . _ mm MAINTENANCE FACILTY —GAS— VZVVQUlMLff PROPOSED BASINLW"mwz ® MMW CUM KO Ir SIT M y (uNw3) wo CAST FiiA1F A: CC+YEN� EL -375.5 4•r x 1. IN MFICE (4 SIMI --,_ EL -374 OMME FOR SON" (SUE AS RB3MiiED FOR SOW) .4 EL--368.1 EL--368 MUM F L (SLAPfD TO= dVFRF M r:r WFUM Dahl! M BASE (SEE NOTE 4)D CMPAIM CM 5101E BE1 E SECu A —A FIGURE 2: CONCRETE RISER PRIMASF CaMM YOP PRIXAST MW E BSI (SEmm2) 16' DIAM. RCP EXTEND EXISTING CULVERT AS NECESSARY TO ALLOW INSTALLATION OF THE RISER L PME UkTB ff JIMM ON ALL PFIK 2 PKINI T CON WIT WE SHALL O M M TO THE FDLLMC RE41JNlFi NM - A` CRIafiM CMFRBW MIMI 4WD M EL R3FW=Q ASM "5. MM 6G C. MEM 11-20 LOADIK 1 AM11E SFPS FOR W NEFS NDII Fb45. SM slALL HAVE A FG SPAMC DE Full HEHFF OF TIE mw NFL sm nm STEP r BE m Tw. 4. BASE MUSF BE PHYWAi17 ATUDS OR 11FMAIM KM IW OEM (F THE RM SIM)CRRE. CHAA1l: ADMINISTRATIVE AND MAINTENANCE FACILITY EXISTING v. PROPOSED DISCHARGE 140 160 120 100 97 cm 80 11 H,o 40 20 0 25 50 75 100 YEAR RETURN OF 24-HOUR NOAA STORM EVENT 151 36 --*—Existing —11—Proposed • •. •``� ,jam All I North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P.E. Dee Freeman Governor Director Secretary October 24, 2012 Mr. Bill Davidson -General Manager Waste Industries LLC 148 Stone Park Ct. Durham, NC 27703 Subject: Compliance Evaluation Inspection Waste Industries LLC Certificate of Coverage No. NCG080845 Durham County Dear Mr. Davidson: On October 24, 2012, Thomas Ascenzo of the Raleigh Regional Office (RRO) conducted a compliance inspection (CEI) of Waste Industries, LLC stormwater pollution program. The assistance of yourself was appreciated as it facilitated the inspection process. The Waste Industries, LLC facility discharges stormwater to receiving waters designated as Northeast Creek in the Neuse River Basin. The following observations were made: 1. The Stormwater Pollution Prevention Plan (SP3) was reviewed and revealed the following : • The plan contained the required general location map that included outfall location and drainage areas. • Employee training documents were included in the SP3. Last training was on March 7, 2012. • List of responsible parties for Emergency spill response notification. • No spills were noted for the 3 year period as observed in the documentation in the manual. • Plan included Stormwater Facility Inspection reports • Best Management Practices summary. • Current Certificate of Coverage • Narrative description of practices. • Spill prevention and response plan. • Plan is being updated annually and as needed. :VorthCaro Iina Naturallr� North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service Internet: www.ncwaterquality.org 1623 Mail Service Center Raleigh, NC 27699.1628 FAX (919) 788-7159 877-623-6748 An Equal Qoaortunity/Affirmative Action Employer — 50% Recycled110% Post Consumer Paper Waste Industries, LLC. CEI NCG080845 Page 2 of 2 2. Qualitative monitoring results were not available at the time of inspection. Forms and guidance to conduct Qualitative monitoring will be provided with this report. Qualitative monitoring is a permit condition and must be conducted semi-annually. 3. Analytical Monitoring is being conducted monthly, The facility is in Tier 2 status due to benchmark exceedences of total suspended solids (TSS). Richardson Gardner and Associates is the consultant conducting the investigation. TSS was within the benchmark for the sample taken on September 21, 2012. 4. Outfall #1 was observed to be dry. Please continue your diligence in the. Stormwater Pollution Prevention Plan. Should you or your staff have any questions regarding this inspection or this correspondence, please do not hesitate to contact me at 919-791-4256 or you can e-mail me at tom.ascenzoCq�,ncdenr.gov. Attachment: Compliance Inspection Reports CC: Raleigh Regional Office SWP John Pfleger- Safety Manager 145 Stone Park Ct, Durham, NC 27703 Sincerely, Thomas Ascenzo Environmental Specialist Surface Water Protection Permit: NCGO80845 SOC: County: Durham Region: Raleigh Compliance Inspection Report Effective: 12/21/09 Expiration: 10/31/12 Owner: Waste Industries LLC Effective: Expiration: Facility: Waste Industries, LLC-Durham 148 Stone Park Ct Contact Person: Richard Johnson Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: • 10/24/2012 Primary Inspector: tam ascenzo Secondary Inspector(s): Title: Entry Time: 11:50 AM Durham NC 27703 Phone: 800-342-7920 Certification: Exit Time: 12:20 PM Phone: Phone: 919-791-4200 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Transportation w/Vehicle Maintenance/Petroleum Bulk/Oil Water Separator Stormwater Discharge COC Facility Status: ■ Compliant Not Compliant Question Areas: ® Storm Water (See attachment summary) Page: 1 Permit: NCG080845 Owner - Facility: Waste Industries LLC Inspection Date: 1012412012 Inspection Type: Compliance Evaluation Stormwater Pollution Prevention Plan Reason for Visit: Routine Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ■ ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ Cl # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ■ ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ■ ❑ ❑ ❑ Comment: Last Employee training was conducted on 3/7/2012 Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ■ ❑ ❑ Comment: Qualitative Monitoring has not been conducted, Proper forms will be provided with guidance to conduct Qualitative monitoring sem- annually as per permit requirements. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ■ ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ❑ ■ Comment: Facility is in Tier 2 due to TSS being over benchmark. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ■ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ Cl # Has the facility evaluated all illicit (non stormwater) discharges? 1111111113 ❑ Page: 3 Permit: NCGO80845 Owner - Facility: Waste Industries LLC Inspection Date: 1012412012 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Outfall #1 inspected, sampling point is located in a storm drain located in the street. Approach to outfall is lined with rip rap and is void of any pollutants.. At the time of inspection the outfall was dry. Page: 4 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG080000 CERTIFICATE OF COVERAGE No. NCGO80845 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, WASTE INDUSTRIES, LLC is hereby authorized to discharge stormwater from a facility located at Waste Industries - Durham 148 Stone Park Court Durham Durham County WS-v to receiving waters designated as Northeast Creek, a class¢; NSW water in the Cape Fear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, III, 1V, V, and VI of.General Permit No. NCG080000 as attached. This certificate of coverage shall become effective December 21, 2009. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day December 21, 2009. ORiGiNAL SIGNED F! KEN PICKLE for Coleen H. Sullins., Director Division of Water Quality By the Authority of the Environmental Management Commission LOCATION MAP: Ij 6 J, 7U Ve x 'YV. sr J­T �f 11 J �. -�� �,.Yr � ` ��ss�`, + •I t �,_� S� ., . !� „I`'�• \\' `e �— �r � I .� L �. •+'!.I _ -f 11♦' • A.2,• '` IN V 'Y' W" �NN ell Waste Industries Wh UU1 I Idl I I ek IV, rj —7� f' V ly 7�. %j NCGO80845 \k? J k S M9,0 Scale 1 :20,000 WASTE INDUSTRIES, LLC WASTE INDUSTRIES --DURHAM Lab bide: 35"1 57' 0 2 " N Longibide: 7811 51' 12" W County: Durham ReceMng Steam: Northeast Creek Stream Class�.S_ ; NSW Sub -basin: C?_'60Y&05 (Cape Fear River Basin) Facility Location Larsen, Cory From: Nisely, Myrl sent: Friday, December 18, 2009 11:37 AM To: Larsen, Cory cc: Smith, Danny Subject: Durham Waste Industies Permit Danny and I recommend that you go ahead and issue the NCG08 permit specifically for the Vehicle Maintenance part of the site. The RRO request that you include in the permit cover letter: 1) The adjacent Transfer Station is not covered by this permit, 2) the RRO's expectations of the adjacent Transfer Station is that exposed areas are to be addressed such that stormwater does not commingle with leachate/residuals from offloading and truck traffic , and 3) if concerns at the Transfer Station are not or cannot be satisfactorily addressed additional permitting may be required. Myrl A. Nisely <°))))>< Environmental Chemist NC DENR - Div. Water Quality Raleigh Regional Office 1628 Mail Service Center Raleigh, NC 27699-1628 Telephone: (919) 791-4200 or x4255 Fax: (919) 788-7159 myrl.nisely(incdenr.gov ><((((°> E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. ;% Larsen, Co From: Larsen, Cory Sent: Friday, October 16, 2009 11:04 AM To: Wiggins, Mack Subject: Waste Industries - Durham NCGO80845 Attachments: NOLpdf; Site Plan.pdf; Topo,pdf Mack, How's it going? The attached facility has submitted for coverage under NCG08. I don't see any problems with the application but wanted to check if you had any comments on them. Maybe you have paid them a visit and that is what prompted the application? Let me know if I should issue to not when you get a chance. Thanks. Cory Cory Larsen Environmental Engineer NCDENR I DWQ I Stormwater Permitting Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 512 N. Salisbury St, Raleigh, NC 27604 Phone: (919) 807-6365 Fax: (919) 807-6494 E-mail correspondence to and from this address may be subject to the North Carolina Public Records haw and may be disclosed to third parties. y a CE*, �4,h�r A-s of M/l71oq • —CAL If13o t T5- 61 y " - tv rl 6L i -P,• V HAZARDOUS DECOMPOSITION PRODUCTS: Acetylene decomposes at high pressure to its constituent elements of carbon and hydrogen. Carbon monoxide may be produced from burning. Under certain conditions, acetylene forms readily explosive acetylide compounds when in contact with copper, silver, and mercury. Therefore, use of acetylene and these metals, or their salts, compounds, and high concentration alloys should be avoided. The presence of moisture, certain acids or alkaline materials tends to enhance the formation of copper acetylides. HAZARDOUS POLYMERIZATION: Temperatures as low as 250°F (121°C) at high pressure, or at low pressure in the presence of a catalyst are sufficient to initiate a polymerization reaction. The hazard here is that the polymerization normally liberates heat and may, therefore, lead to ignition and decomposition of acetylene if conditions permit. 11. Toxicological Information Low concentrations (10-20% in air) cause symptoms similar to that of being intoxicated. As a narcotic gas or intoxicant, it causes hypercapnia (an excessive amount of carbon dioxide in the blood). Repeated exposures to tolerable levels has not shown deleterious effects. TCLo, human - Inhalation of 20 ppb inhaled has been shown to cause headache and dyspnea. Oxygen deficiency during pregnancy has produced developmental abnormalities in humans and experimental animals. 12. Ecological Information No data given. 13.• Disposal Considerations Do not attempt to dispose of residual waste or unused quantities. Return in the shipping container PROPERLY LABELED, WITH ANY VALVE OUTLET PLUGS OR CAPS SECURED AND VALVE PROTECTION CAP IN PLACE to BOC Gases or authorized distributor for proper disposal. 14. Transport Information #YARMER ` I1 te. St ... >.O . PROPER SHIPPING NAME: Acetylene, dissolved : Acetylene, dissolved, HAZARD CLASS: 2.1 2.1 IDENTIFICATION NUMBER:. UN 1001 UN 1001 SHIPPING LABEL: FLAMMABLE GAS FLAMMABLE GAS 15. Regulatory Information U.S. FEDERAL REGULATORY INFORMATION MSDS: G-2 Revised: 6/7/96 Page 70f 9