Subject: Compliance Evaluation Inspection
Kenly 95 TA Truckshop Facility
Stormwater Permit No. NCGO80055
Johnston County
Dear Mr. Brame:
1, Mitch Hayes, of the Raleigh Regional Office conducted a Compliance Evaluation Inspection at the
subject facility on July 12, 2012. Yours and John Keen's assistance with this inspection was greatly
appreciated. Please find the attached Basinwide Information Management System (BIMS) checklist
summarizing the inspection. Below is a list of findings and recommendations developed from the inspection:
1. The General Permit NCG080000 was issued November 01, 2007 and will expire October 31, 2012.
Request for permit renewal was mailed out from the Central Office in March 2012. Please continue
to operate under the last issued permit until a new permit is issued.
2. The facility consists of a covered truck fueling depot, truck maintenance shop, truck wash, covered
gasoline fueling depot, various storage buildings, various restaurants and outparcels, truck and car
parking lots situated on approximately 29.4 acres.
3. Approximately 14 acres are non -pervious. The rest of the land is grassed and includes three
stormwater retention ponds. There are stormdrains located throughout the parking lot to convey
stormwater runoff to the three stormwater retention ponds in series. The two upper ponds, situated
in a north south configuration, are connected by a pipe to maintain a constant water level. The
southern upper pond has an overflow pipe that discharges waterto the third smaller pond which is at
a lower elevation than the upper two ponds. According to the Division of Land Resources, the third
smaller pond discharges to a level spreader below the lower pond. Water in all three ponds
appeared clear with no sheen noted.
4. Absorbent booms are place in the receiving northern upper stormwater retention pond. There is an
oil water separator for the fuel line that discharges to the stormdrain and an oil water separator for
the shop that discharges to the Town of Kenly wastewater collection system. Nobile Oil pumps out
the oil water separators as needed. There is no secondary containment for the fueling pad area
however; oil absorbent pads and booms are readily available in case of spills. Water forthe truck
wash is reused and eventually discharged to the Town of Kenly wastewater collection system.
5. A current stormwater permit was not available for the inspection. A copy of the general permit
NCG080000 was given to you during inspection. Please be sure to read and follow all permit
requirements. Failure to follow permit NCGO80054 conditions is subject to enforcement action and
penalties up to $25,000 per day. A Stormwater Pollution Prevention Plan was available. It is well
North Carolina Division of Water Quality 1628 Mail Service Center Raleigh, NC 276W28 Phone (919) 7914200 Customer Service
Internet: www.ncwaterquality.ora Location: 3800 Barrett Drive Raleigh, NC 27609 Fax (919) 788-7159 1-877-623-6748
One
An Equal Opportunity/Affirmative Action EmployeF 50% Recycled110% Post Consumer Paper NNorthCarolina
Kenly 95 Petro CEI
Page 2
written and contains all permit requirements.
6. You stated your facility uses over 55 gallons of oil per month when averaged over 12 months.
Please follow the analytical monitoring requirements and schedule as listed in Section B, Table 1
and 2. The discharge outfall listed on site map will require analytical monitoring and qualitative
monitoring. Analytical and qualitative monitoring forms are available on the Division of Water
Quality's web page http://portal.ncdenr.or-q/web/wg/ws/su/npdessw#tab3 under the monitoring
forms tab. Scroll down to NCG080000 SDO form. The qualitative monitoring form is at the top of the
page.
would like to thank you and John Keen again for your time and assistance with this inspection. If you
have any questions about this letter or the inspection, please contact me at 919.791.4261 or by email at
mitch.hayes(@ncdenr.ctov.
Sincerely,
Mitch Hayes
Environmental Specialist
Cc: Permit files, Central files
f
Compliance Inspection Report
Permit: NCGO80065 Effective: 09/01/02 Expiration: 08/31/07 Owner: Corbitt Partners LLC
SOC: Effective: Expiration: Facility: Kenly 95 TA Truckshop
County: Johnston 923 Johnston Pkwy
Region: Raleigh
Kenly NC 27542
Contact Person: Mike Lowe Title: Phone: 919-284-5121
Directions to Facility:
System Classifications:
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
24 hour contact name Ernie Brame Phone: 919-284-5121
On -site representative Ernie Brame Phone: 919-284-5121
Related Permits:
Inspection Date: 07/12/2012 Entry Time: 01:0}0 PM Exit Time: 02:00 PM
Primary Inspector: Mitchell S Hayes �j'�(X� �%�, �`f,1 Z Phone: 919-791-4200
Secondary Inspector(s):
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Transportation w/Vehicle Maintenance/Petroleum Bulk/Oil
Water Separator Stormwater Discharge COC
Facility Status: ❑ Compliant Q Not Compliant
Question Areas:
Storm Water
(See attachment summary)
Page: 1
Permit: NCGO80065 Owner - Facility: Corbitt Partners LLC
Inspection Date: 07/12/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
The facility consists of a covered truck fueling depot, truck maintenance shop, truck wash, covered gasoline fueling depot,
various storage buildings, various restaurants and outparcels, truck and car parking lots situated on approximately 29.4
acres.
Approximately 14 acres are non -pervious. The rest of the land is grassed and includes three stormwater retention ponds.
There are stormdrains located throughout the parking lot to convey stormwater runoff to the three stormwater retention
ponds in series. The two upper ponds, situated in a north south configuration, are connected by a pipe to maintain a
constant water level. The southern upper pond has an overflow pipe that discharges water to the third smaller pond which
is at a lower elevation than the upper two ponds. According to plans and specifications in the Land Quality Section, the
third smaller pond discharges to a level spreader below the lower pond. Water in all three ponds appeared clear with no
sheen noted.
Absorbent booms are place in the receiving northern upper stormwater retention pond. There is an oil water separator for
the fuel line that discharges to the stormdrain and an oil water separator for the shop that discharges to the Town of Kenly
wastewater collection system. Nobile Oil pumps out the oil water separators as needed. There is no secondary
containment for the fueling pad area however; oil absorbent pads and booms are readily available in case of spills. Water
for the truck wash is reused and eventually discharged to the Town of Kenly wastewater collection system.
A current permit was not available for inspection. Mr. Brame was unaware of permit monitoring reguriements and
therefore there are no montoring reports to check. Facility is subject to analytical monitoring requirements.
Page: 2
Permit: NCG080065 - Owner - Facility: Corbitt Partners LLC
Inspection Date: 07/12/2012 Inspection Type: Compliance Evaluation
Reason for Visit:
Routine
Stormwater Pollution Prevention Plan
Yes
No
NA
NE
Does the site have a Stormwater Pollution Prevention Plan?
■
n
n
❑
# Does the Plan include a General Location (USGS) map?
■
n
n
n
# Does the Plan include a "Narrative Description of Practices"?
■
Cl
n
n
# Does the Plan include a detailed site map including outfall locations and drainage areas?
■
n
n
n
# Does the Plan include a list of significant spills occurring during the past 3 years?
■
❑
n
# Has the facility. evaluated feasible alternatives to current practices?
■
n
n
n
# Does the facility provide all necessary secondary containment?
■
o
n
n
# Does the Plan include a BMP summary?
■
n
n
n
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
■
n
n,
n
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
# Does the facility provide and document Employee Training?
# Does the Plan include a list of Responsible Parly(s)?
# Is the Plan reviewed and updated annually?
# Does the Plan include a Stormwater Facility Inspection Program?
Has the Stormwater Pollution Prevention Plan been implemented?
Comment:
Qualitative Monitoring
Has the facility conducted its Qualitative Monitoring semi-annually?
Comment: Was not aware of monitoring requirements.
Analytical Monitoring
Has the facility conducted its Analytical monitoring?
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas?
Comment: Was not aware of monitoring requirements.
Permit and Ouffalls
# Is a copy of the Permit and the Certificate of Coverage available at the site?
# Were all outfalls observed during the inspection?
# If the facility has representative outfall status, is it properly documented by the Division?
# Has the facility evaluated all illicit (non stormwater) discharges?
Comment: Permit was not available for inspection. Gave Mr. Brame a copy of
NCG080000 permit.
■nnn
■nnn
Yes No NA NE
Yes No NA NE
Yes No NA NE
Page: 3
W A 7' Michael F. Easley, Governor
� William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
p ,Alan W. Klimek, P.E. Director
Divisiu of.WaterQuality
December 2, 2005j
Mr. Ernest D. Brome ;tip Vj
Corbitt Partners, LLC
923 Johnston Parkway t t,
Kenly, NC 27512 f� .
Subject: NPDES General Permit NCGO80000
Certificate of Coverage NCGO80065
Kenly 95 TA Truckstop
Formerly Stallings Oil Company-Kenly
Johnston County
Dear Mr. Brome:
Division personnel have reviewed and approved your request to transfer coverage under the General Permit,_
received on November 17, 2005.
Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General
Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of
North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S.
Environmental Protection Agency.
If you have any questions, please contact the Stomnwater Permitting Unit at (919) 733-5083, extension 502.
Sincerely,-'
? 0RlGiNA! SIGNED BY
'Aing�gDLEY BENNETT
. Klimek P. E.
cc: DWQ Central Files
Raleigh Regional Office, Water Quality Section
Stormwater Permitting Unit
I, &Carolina
JUatura!!y
North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service
Intemet h2o.enrstale.ncus 512 N. Salisbury St. -Raleigh, NC 27604 FAX (919) 733-2496 1-977-623-6749
An Equal OpportunitylAlfirm ive Acton Employer — 509b Recydedllo% Post Consumer Paper
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
GENERAL PERMIT NO. NCG080000
CERTIFICATE OF COVERAGE No. NCG080065
STORMWATER DISCHARGES
NATIONAL POLLUTANT DISCHARGE ELIMMATION SYSTEM
In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and
regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the
Federal Water Pollution Control Act, as amended,
CORBITT PARTNERS, LLC
is hereby authorized to discharge stormwater from a facility located at
KENLY 95 TA TRUCKSTOP
923 JOHNSTON PARKWAY
KENLY
JOHNSTON COUNTY
to receiving waters designated as the Little River, a class WS-IV NSW stream, in the Neuse River Basin in
accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, III, IV,
V, and VI of General Permit No. NCG080000 as attached.
This certificate of coverage shall become effective December 2, 2005.
This Certificate of Coverage shall remain in e4ct for the duration of the General Permit.
3�IrL�^s,^3�i,y •
Signed this dayDecember 2, 2005. i3Y
Alan W `Klimek, Director
Division of Water Quality
By Authority of the Environmental Management Commission
OD
town
J ! [ l o :b - x, � • r Cem
°�.� ° �%I 1 • \ .
'COAST a
r I J` '''+►'•: � ''�Sewage0-1
Cem
posa
2342
uni
2385
•'-
Line
Lary 9 Y r`
a7: 1, 1 , . 1' tug
I Cerrr; i
234
_. * • ; - � `fir.' � 1- °'. O rsv
KH
GH
b Location M
I ll v
1076MiLS C38' .. Truckland, Inc: N
29 MILS j KBnly, North Carolina c • I�
4 1 v- % / from USGS 7.5 Minute Series Map den
1 QUADRANGLE LOCATION '
- Kenly West, N.C. °
SCALE 1:24 000
.e;. T 0 1 MILE
1000 D 1000 2000 3000 4000 SOW 5000 70W FEET
• 1.. .5 0 1 KILOMETER23
r °
/ V 2355
CONTOUR INTERVAL 10 FEET -�
��� 7� NATIONAL GEODETIC YERTICAL DATUM OF 1929 `
-r
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Alan W. Klimek, P.E_, Director
Division of Water Quality
August 23, 2002
ERNIE BRAME
STALLINGS OIL CO-KENLY
923 JOHNSTON PARKWAY
KENLY, NC 27542
Subject: NPDES Stormwater Permit Renewal
Stallings Oil Co-Kenly
COC Number NCGO80065
Johnston County
Dear Permittee:
In response to your renewal application for continued coverage under general permit NCG080000, the Division of
Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued
pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement
between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983.
The following information is included with your permit package:
A new Certificate of Coverage
A copy of General Stormwater Permit NCGO80000
A copy of a Technical Bulletin for the general permit
Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require
modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal
requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility
for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or
decree.
If you have any questions regarding this permit package please contact Delonda Alexander of the Central Office
Stormwater and General Permits Unit at (919) 733-5083, ext. 584
Sincerely,
Bradley Bennett, Supervisor
Stormwater and General Permits Unit
cc: Central Files
Stormwater & General Permits Unit Files
Raleigh Regional Office
VAv
NCDENR
N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Customer Service
1-800-623-7748
MIKE LOWE
STALLINGS OIL CO-KENLY
923 JOHNSTON PARKWAY
KENLY. NC 27542
Dear Permittee:
Michael F. Easley, Governor
William G. Ross Jr.,Secretary
North Carolina Department of Environment and Natural Resources
Gregory J. Thorpe, Ph.D.
Acting Director
Division of Water Quality
December 27, 2001
r �
?004 ry 'yam,
Subject: NPDES Stormwatef?-[ rmit Renewal19�
STALLINGS OIL CO-KENLY
COC Number NCG080065
Johnston County
Your facility is currently covered for stormwater discharge under General Permit NCG080000. This permit expires
on August 31, 2(I)2. The Division staff is currently in the process of rewriting this permit and is scheduled to have
the permit reissued by late summer of 2002- Once the permit is reissued, your facility would be eligible for
continued coverage under the reissued permit.
In order to assure your continued coverage under the general permit. you must apply to the Division of Water
Quality (DWQ) for renewal of your permit coverage: To make this renewal process easier, we are informing you in
advance that your permit will be expiring. Enclosed you will find a General Permit Coverage Renewal
Application Form. The application must be completed and returned by March 4, 2002 in order to assure continued
coverage under the general permit.
Failure to request renewal within this time period may result in a civil assessment of at least $250.00. Larger
penalties may be assessed depending on the delinquency of the request. Discharge of stormwater frorn your facility
without coverage under a valid stormwater NPDES permit would constitute a violation of NCGS 143-215.1 and
could result in assessments of civil penalties of up to $10.000 per day.
Please note that recent federal legislation has extended the "no exposure exclusion" to all operators of industrial
facilities in any of the 1 I categories of "storm water discharges associated with industrial activity." (except
construction activities). If you feel your facility can certify a condition of "no exposure", i.e. the facilty industrial
materials and operations are not exposed to stormwater, you can apply for the no exposure exclusion. For additional
information contact the Central Office Stormwater Staff member listed below or check the Stormwater'&. General
Permits Unit Web Site at hitp:/fh2o.enr.state.nc.us/su/stormwater.html
If the subject stormwater discharge to waters of the state has been terminated, please complete the enclosed
Rescission Request Form. Mailing instructions are listed on the bottom of the form. You will be notified when the
rescission process has been completed.
If you have any questions regarding the permit renewal procedures please contact Joe Albiston of the Raleigh
Regional Office at 919-571-4700 or Delonda Alexander of the Central Office Stormwater Unit at (919) 733-5083,
ext. 584
Sincerely.
Bradley Bennett, Supervisor
Stormwater and General Permits Unit
cc: Central Files
Raleigh Regional Office
NCDENR
N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Customer Service
1-800-623-7748
1,
State of North Carolina
Department of Environment,
Health and Natural Resources
Division of Environmental Management
James B. Hunt, Jr., Governor
Jonathan B. Howes, Secretary
A. Preston Howard, Jr., P.E., Director
Mr. Mike Lowe
Truckland, Inc.
968 Flowers Road
Kenly, NC 27542
Dear Mr. Lowe:
February 4, 1994
Subject: Authorizac.�itRQ
Truckland
NCG080065
Johnston County
In accordance with your application for an NPDES discharge permit received on
November 17, 1992 by the Division, we are herewith forwarding the subject Authorization
to Construct for the construction and operation of a stormwater basin with an oil/water
separator and sand filter for fueling area run-off with discharge of treated stormwater into
an unnamed tributary to the Little River in the Neuse River Basin. This Authorization to
Construct is issued pursuant to the requirements of North Carolina and the US
Environmental Protection Agency Memorandum of Agreement dated December 6, 1983
and as subsequently amended.
This Authorization to Construct is issued in accordance with Part -In, Paragraph 2
of NPDES Permit No. NCG080000, and shall be subject to revocation unless the
wastewater treatment facilities are constructed in accordance with the conditions and
limitations specified in Permit No. NCG080000.
In the event that the facilities fail to perform satisfactorily, including the creation of
nuisance conditions, the Permittee shall take immediate corrective action, including those as
may be required by this Division, such as the construction of additional or replacement
wastewater treatment or disposal facilities.
The Raleigh Regional. Office, telephone number (919) 571-4700, shall be notified at
least forty-eight (48) hours in advance of operation of the installed facilities so that an in -
place inspection can be made. Such notification to the regional supervisor shall be made
during the normal office hours from 8:0.0 a.m. until 5:00 p.m. on Monday through Friday,
excluding State Holidays.
A copy of the approved plans and specifications shall be maintained on file by the
Permittee for the life of the facility.
Failure to abide by the requirements contained in this Authorization to Construct
may subject the Permittee to an enforcement action by, the Division of Environmental
Management in accordance with North Carolina General Statute 143-215.6A to 143-
215.6C.
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer gaper '
Page 2
NCG080065
February 4, 1994
The issuance of this Authorization to Construct does not preclude the Permittee from
complying with any and all statutes, rules, regulations, or ordinances which may be
required by the Division of Environmental Management or permits required by the Division
of Land Resources, the Coastal Area Management Act or any Federal or Local other
governmental permit that may be required.
If you have any questions concerning this matter, please contact Susan Robson
(919) 733-5083.
Sincerely,
Original Stgned By
David A. Goodrich
A. Preston Howard, Jr., P.E.
cc: jRZ9i—gR4MfMMRRce
Central Files
Permits and Engineering Unit
2.
}.
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES
DIVISION OF ENVIRONMENTAL MANAGEMENT
J
STORMWATER DISCHARGES
In compliance with the provision of North Carolina General Statute 143-215,1, other lawful standards and
regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the
Federal Water Pollution Control Act, as amended,
Truckland, Inc.
is hereby authorized to construct and operate an oil/water separator and sand filter and discharge treated stormwater
from a facility located at
Exit 105
off of I-95
Kenly
Johnston County
to receiving waters designated as an unnamed tributary to the Little River in the Neuse River Basin
in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 11, III
and IV of General Permit No. NCG080000 as attached.
This Certificate of Coverage shall become effective February 4, -1994
This Certificate of Coverage shall remain in effect for the duration of the General Permit.
Signed this day February 4, 1994
Original Signed By
David A. Goodrich
A. Preston Howard, Jr., P.E., Director
Division of Environmental Management
By Authority of the Environmental Management Commission
-Gem
Nj
\ 2 2143
tOWII a • 6/
Il "Cem
.r '� 1._ C �� � '\���• 2165 ,4$� �E 301 "�.."sy•
✓'y_• .-/i .'�r_4. �' .n - --. ._ tom' •It
••�
l'' -✓ Sewage
— _iL \ ` .' Disposal �-2342\" I
TRUNKLAN17,
r�ll _ ;r: um �� •,gam /
2385
205
t Baglev
Loxmlf cal -
'� ` '.Cem
Coast :Cem
Q,
Lowell
• — ° 5
` / /90
* • \ —\. , °
MN
GH
/-tx kzzz�
f r Location Map
107 M14s L / Truckland, Inc.. j N.C.■
29 M«5 1
Kenly, North Carolina 15d
. from USGS 7.5 Minute Series Ma - cin
! ! ',' � � � p QUADRANGLE LOCATION
Kenly West, N.C.
Y ,
1 -SCALE 1:24 000
o} L ? 0 1 MILE
1000 0 1000 2000 300o 4000 5000 6000 7000 FEET
23 1 .5 0 1 KILOMETER \
CONTOUR INTERVAL 10 FEET � 2355 J .
NATIONAL GEODETIC VERTICAL DATUM OF 1929
1
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Gregory J. Thorpe, Ph.D.
Acting Director
Division of Water Quality
December 27, 2001
MIKE LOWE
STALLINGS OIL CO-KENLY
923 JOHNSTON PARKWAY
KENLY. NC 27542
Subject: NPDES Stormwater Permit Renewal
STALLINGS OIL CO-KENLY
COC Number NCGO80065
Johnston County
Dear. Perm i ttee:
Your facility is currently covered for stormwater discharge under General Permit NCG080000. This permit expires
on August 31. 2002. The Division staff is currently in the process of rewriting this permit and is scheduled to have
the permit reissued by late summer of 2002. Once the permit is reissued. your facility would be eligible for
continued coverage under the reissued permit.
In order to assure your continued coverage under the general permit, you must apply to the Division of Water
Quality (DWQ) for renewal of your permit coveraffe. To make this renewal process easier. we are informing you in
advance that your permit will be expiring. Enclosed you will find a General Permit Coverage Renewal
Application Form. The application must be completed and returned by March 4. 2002 in order to assure continued
coverage under the general permit.
Failure to request renewal within this time period may result in a civil assessment of at least $250.00. Larger
penalties may be assessed depending on the delinquency of the request. Discharge of stormwater from your facility
without coverage under a valid stormwater NPDES permit would constitute a violation of NCGS 143-215.1 and
Cr
could result in assessments of civil penalties of up to $10,000 per day.
Please note that recent federal legislation has extended the "no exposure exclusion" to all operators of industrial
facilities in any of the 1 I categories of "storm water discharges associated with industrial activity," (except
construction activities). If you feel your facility can certify a condition of "no exposure", i.e. the facilty industrial
materials and operations are not exposed to stormwater, you can apply for the no exposure exclusion. For additional
information contact the Central Office Stormwater Staff member listed below or check the Stormwater & General
Permits Unit Web Site at http://h2o.enr.state.nc.us/su/storTnwater.html
If the subject stormwater discharge to waters of the state has been terminated, please complete the enclosed
Rescission Request Forma Mailing instructions are listed on the bottom of the form. You will be notified when the
rescission process has been completed.
If you have any questions regarding the permit renewal procedures please contact Joe Alhiston of the Raleigh
Regional Office at 919-571-4700 or Delonda Alexander of the Central Office Stormwater Unit at (919) 733-5083.
ext. 584
Sincerely,
Bradley Bennett. Supervisor
Stormwater and General Permits Unit
cc: Central Files
Raleigh Regional Office
G'A
NCDENR
N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Customer Service
t- 800-623-7748
"'1 ' 196.
GENERAL PERMITS
COPIES OF PERMITS ARE TO BE SENT
TO THE FOLLOWING:
4 SIGNED ORGINAL TO APPLICANT **
7SIGNED COPY TO CENTRAL FILES
COPY TO REGIONAL OFFICE
COPY TO P&E FILE
COPY TO COMPLIANCE
COPY TO WAKE COUNTY
_COPY TO M ECKLENBURG COUNTY
COPY TO TRAINING & CERT.**
**ATTACH COPY OF GENERAL PERMIT
-State of North Carolina
Department of Environment,
Health and Natural Resources A
T0 0
Division of Environmental Management rr
James B. Hunt, Jr., Governornow
Jonathan B. Howes, Secretary C) C H F1
A. Preston Howard, Jr., P.E., Director G V
February 4, 1994
Mr. Mike Lowe
Truckland, Inc.
968 Flowers Road
Kenly, NC 27542
Subject: Authorization to Construct
Truckland, Inc.
NCGO80065
Johnston County
Dear Mr. Lowe:
In accordance with your application for an NPDES discharge permit received on
November 17, 1992 by the Division, we are herewith forwarding the subject Authorization
to Construct for the construction and operation of a stormwater basin with an oil/water
separator and sand filter for fueling area run-off with discharge of treated stormwater into
an unnamed tributary to the Little River in the Neuse River Basin. This Authorization to
Construct is issued pursuant to the requirements of North Carolina and the US
Environmental Protection Agency Memorandum of Agreement dated December 6, 1983
and as subsequently amended.
This Authorization to Construct is issued in accordance with Part III, Paragraph 2
of NPDES Permit No. NCG080000, and shall be subject to revocation unless the
wastewater treatment facilities are constructed in accordance with the conditions and
limitations specified in Permit No. NCG080000.
In the event that the facilities fail to perform satisfactorily, including the creation of
nuisance conditions, the Permittee shall take immediate corrective action, including those as
may be required by this Division, such as the construction of additional or replacement
wastewater treatment or disposal facilities.
The Raleigh Regional Office, telephone number (919) 571-4700, shall be notified at
least forty-eight (48) hours in advance of operation of the installed facilities so that an in -
place inspection can be made. Such notification to the regional supervisor shall be made
during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday,
excluding State Holidays.
A copy of the approved plans and specifications shall be maintained on file by the
Permittee for the life of the facility.
Failure to abide by the requirements contained in this Authorization to Construct
may subject the Permittee to an enforcement action by the Division of Environmental
Management in accordance with North Carolina General Statute 143-215.6A to 143-
215.6C.
1
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX. 919-733-9919
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper
t
Page 2
NCG080065
February 4, 1994
The issuance of this Authorization to Construct does not preclude the Permittee from
complying with any and all statutes,. rules, regulations, or ordinances which may be
required by the Division of Environmental Management or permits required by the Division'
of Land Resources, the Coastal Area Management Act, or any Federal or Local other
governmental permit that may be. required.
If you have any questions concerning this matter, please contact Susan Robson
(919) 733-5083.
Sincerely,
():;ginal signed By
pallid A. Goodrich
cc: Raleigh Regional Office
Central Files
Permits and Engineering Unit
A. Preston Howard, Jr., P.E.
V.
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES
DIVISION OF ENVIRONMENTAL MANAGEMENT
► � �u ►! ► I:Illf
LWPI
! ! �:_ ►! I:il�
STORMWATER DISCHARGES
In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and
regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the
Federal Water Pollution Control Act, as amended,
Truckland, Inc.
is hereby authorized to construct and operate an oil/water separator and sand filter and discharge treated stormwater
from a facility located at
Exit 106
off of 1-95
Kenly
Johnston County
to receiving waters designated as an unnamed tributary to the Little River in the Neuse River Basin
in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, II, III
and IV of General Permit No. NCG080000 as attached.
This Certificate of Coverage shall become effective February 4, 1994
This Certificate of Coverage shall remain in effect for the duration of the General Permit
Signed this day February 4, 1994
Original Signed By
David A. Goodrich
A. Preston Howard, Jr., P.E., Director
Division of Environmental Management
By Authority of the Environmental Management Commission
v'
Ico
7B
Cm-202
\ e
21i3 -
e town 1Ke -; `�' j a.
P
(gyp \ll,
2165 „' d� g 301
}1111,,�111.`-• '1 ,� - ` � � 1,1�� 1 .•• .t
COAST
se wage
TRUC-L ND
2385
BR JI ' ' r f� -�� 205
148
54 lev
Line
1 Low=}f 9
},
Cem
:Cem \
7
1 Cem'- !
Lowell
57
200
MN
CN
4 r Location Mao
Truckland, Inc.
107 miLS I'38' �l r N.G.■ 1�
zs MiLs . Kenly, North Carolina i
from USGS 7.5 Minute Series Map Cen QUADRANGLE LOCATION
Kenly West, N.C.
SCALE 1:24 000
1 z 0 1 MILE .
1000 O 1D00 2000 3000 4000 5000 6000 7000 FEET
' 1 .5 0 1 KILOMETER r`
Y3 P \
CONTOUR INTERVAL 10 FEET -! _. ?355
�^ I NATIONAL GEODETIC VERTICAL DATUM OF 1929
35.5819N 78.1458W - Google Maps
G®ogte
q, Av
Shttp://maps.goo-le.com/maps?q=35.5819N+78.1458W&spn=0.7554...
` `olr,VN via
�-.sC-�C,)� OWL To see all the details that are visible on the
OvAAl I !-j screen, use the'Print" link next to the map.
�a
06
-1
6 �Ox�
� ..
�r
D
JAU+ i
i
Ir } *'
on S,~fe. owner: •Ck-n-erD-13r-orne-;geil%4 ---
�Cn ly 95 T74 -T�-LIIC�
L� 2- 3 �10 �►✓15-1�� t'�. w tLw�-Y
g l � Lary- S u- r
Kvi� Af C, -z--7 s It 2-
Cr 0/ t'-'f -5� r r
pert-p jez- m --k&Z7 Z-
1 M�
JGt � L T;1 t �-�SC7l� � �G n� er
52- 7 T3
5 J tC(r )r, �j.,�_ r 1�Gi "dlC �Z� �
S
t Y
1 of 1 �� ! S7--2 6/19/2012 11:05 AM