HomeMy WebLinkAboutNCG100219_MONITORING INFO_20190415STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
/V Lc l o
DOC TYPE
❑ HISTORICAL, FIDE
MONITORING REPORTS
DOC DATE
❑
YYYYM MDD
N
FILE C\1.
ROY COOPER NORTH CAROLINA
Governor Em!lrohmentui Quality
NCHAEL S. REGAN
Secretary
WILUAM'E. (TOBY) VINSON,A.
lraerim Director
Apri[ 15, 2419
Weaver Parts & U Pull
Attention: Jake Zvanut, Owner
9001 Stitt Street.
Unionville NC 28110
Subject: Compliance Evaluation Inspection
Weaver Parts & U Pull
NPDES Stormwater Certificate of Coverage- NCG100219
Union County, North Carolina
Dear Mr. Zvanut:
Enclosed please find a copy of the Compliance Evaluation Inspection Report for
the inspection we conducted at the Weaver Parts-& U Pull, on April 11, 2019. Please
note that in the stormwater inspection report summary we ask that you maintain
records and determine representative outfalls..
The report should be self-explanatory; however, should you have any questions,
please do not hesitate to contact me at (704) 663-71699 or by E=mait at
james.moore@ncdenr.gov.
Sincerely,
01V �' �
es Moore
Assistant Regional Engineer
Enclosure
c: Stormwater Permitting Branch
North Carolina Department of Environmental Quality i Division or Energy, Mineral and land Resources
Mooresville Regional Office ! 610 East Centre Avenue, Suite 301 I Mooresville, North Carolina 28115
.,11.11.:0...,
Permit: NCGl00219
SOC:
County: Union
Region: Mooresville
Contact Person: Jake Zvanut
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 04/11/2019
Primary Inspector: Lily C Kay
Secondary Inspector(s):
Compllance Inspection Report
Effective: 11/01/18 Expiration: 05/31/21 Owner: Jake Zvanut
Effective: Expiration: Facility: Weaver Parts $ U Pull
9001 Stitt St
Title: Site Manager
Certification:
Unionville NC 28110
Phone: 704-283-6446 Ext.3802
Phone:
Entry Time: 10:30AM Exit Time; 12:00PM
Phone: 704-663-1699
Reason for Inspection: Complaint Inspection Type: Compliance Evaluation
Permit Inspection Type: Used Motor Vehicle Parts Stormwater Discharge COC
Facility Status: Compliant Not Compliant
Question Areas:
Storm Water
(See attachment summary)
Page 1 of 4
permit. NCG100219 Owner -Facility: Jake Zvanut
Inspection Date: 04/11/2019 Inspection Type: Compliance Evaluation Reason for Visit: Complaint
Inspection Summary;
While the facility's SWPPP was complete, records were incomplete at the time of inspection. Only one of the two analytical
sampling events for 2018 was available and the TSS bechamrk limitation was exceeded for the 2018 sample without a Tier 1
response completed. The qualitative monitoring reports were blank for all sampling events. The outlets were not clearly
defined and sampling points should be determined on three sides of the property. These outfalls should be sampled for one
year to determine representative outfall status. If you have any questions, please contact me at Lily.Kay@ncdenr.gov or by
phone at (704) 236-2137.
Page 2 of 4
IF
Psrmit• NCG1002tg Owner - Facility:Jake Zvanul
Inspection Oats: 0411112019 Inspection Type : Compliance Evaluation • Reason for Visit: Complaint
Stormwater Pollution Prevention Plan
Yee No NA NE;
Does the site have a Stormwater Pollution Prevention Plan?
❑ ❑ ❑
# Does the Plan include a General Location (USGS) map?
E ❑ ❑ ❑
# Does the Plan include a "Narrative Description of Practices"?
❑ ❑ ❑
# Does the Plan include a detailed site map Including outfall locations and drainage areas?
❑ ❑ ❑
# Does the Plan include a list of significant spills occurring during the past 3 years?
❑ ❑ ❑
# Has the facility evaluated feasible alternatives to current practices?
❑ ❑ ❑
# Does the facility provide all necessary secondary containment?
E ❑ ❑ ❑
# Does the Plan Include a BMP surnmary?
❑ ❑ ❑
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
❑ ❑ ❑
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
❑ ❑ ❑
# Does the facility provide and document Employee Training?
❑ ❑ ❑
# Does the Plan include a list of Responsible Party(s)?
❑ ❑ ❑
# Is the Plan reviewed and updated annually?
❑ ❑ ❑
# Does the Plan include a Stormwater Facility Inspection Program?
❑ ❑ ❑
Has the Stormwater Pollution Prevention Plan been implemented?
❑ ❑ ❑
Comment: The facilitv does have an annually updated SWPPP with some missina records like a list of
significant spills and qualitative monitoring reports. All records must be maintained for at least -
five years.
Qualitative Monitorina Yes No NA NE
Has the facility conducted its Qualitative Monitoring semi-annually? ❑ 0 ❑ ❑
Comment: While analytical monitoring records were present and complete at the time of inspection, the .
qualitative monitoring reports were blank.
Analytical Monitoring Yes No NA Ng
Has the facility conducted its Analytical monitoring? ❑ ❑ ❑
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ■ ❑ ❑
Comment: Only one of the two required samples per year were taken for_2018. The one sample taken for
2018 exceeded the benchmark limitation for TSS and there was not a Tier 1 response
conducted,
F=
Permit and Outfalls Xgg No NA NE
# Is a copy of the Permit and the Certificate of Coverage available at the site? ❑ ❑ ❑
I
# Were all outfalls observed during the inspection? ❑ ❑ ❑
# If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑
# Has the fticility evaluated all illicit non stormwater discharges?' ❑0 El El
Page 3 of 4
Penult: NCGl00219 Owner •Facility: Jake Zvanut
Inspection Date: 0411112019 Inspection Type. Compliance Evaluation Reason for Visit: Complaint
Comment: The outlets were not clearly defined or designated._ New outlets on both sides and at the back of
the facility should be determined and sampled for a year to determine representative, outfall
status.
Page 4 of 4
STORMWATER DISCHARGE OUTFALL (5DO)
MONITORING REPORT
CERTIFICATE OF COVERAGE NO. NCG100 2 19 SAMPLES COLLECTED DURING CALENDAR YEAR: 2018
(This monitoring report shall be received by the Division no later than 30 days
from the date the facility receives the sampling results from the laboratory.)
FACILITY NAME Weaver Parts and U Pull COUNTY Union
PERSON COLLECTING SAMPLE(S) Dave Barzoff PHONE NO.704-218-3347
CERTIFIED LABORATORY(S) TestAmerica Pensacola Lab # 314
Lab # PLEASE REMEMBER TO SIGN ON THE REVERSE -�
Part A: Stonmwater Benchmarks and Monitoring Results
For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within
30 days of the end of that period to comply with permit reporting requirements.
Outfall
No.
Date
Sample
Collected,
mo/dd/year
Total
Rainfall,
inches
00400
00530
----
77023
01051
78141
pH,
Standard
Units
Total Suspended
Solids (TSS),
mg/L
Non -polar
O&G/TPH
(Method 1664
SGT-HEM), mg/L
Ethylene Glycol,
mg/L
Lead, Total
Recoverable,
mg/L
Total Toxic
Organics3,
mg/L
Benchmark
-
-
6.0-9.01
100/502
15
8,000
(Tiers 2 and 3)
0.03
1.0
001
08/09/2018
0.04
380
2.0
< 12
0.057
Exempt
002
Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General
Permit.
1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark
range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented
to demonstrate background concentrations were below the benchmark pH range of 6-9.
2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters.
3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122.
Form SW U-251, last revised October 25, 2012
Page 1 of 2
STORMWATER DISCHARGE OUTFALL (SDO)
MONITORING REPORT
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent
management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the
discharger shall sign the following certification statement:
Solvent Management Plan Certification Statement
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I
certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent
management plan included in the Stormwater Pollution Prevention Plan."
I V6- Ae��
Name (Print name)
��4t74-/
Mail Original and one copy to:
Division of Water Quality
Attn: Central Files
1617 Mail Service Center
North Carolina 27699-1617
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aw rsignificant penal ' or submitting false information, including the possibility of fines and imprisonment for knowing violations."
(Signature of
%I A %,
(D e)
Form SWU-251, last revised October 25, 2012
Page 2 of 2
CERTIFICATE OF COVERAGE NO. NCG100 _219_ _
STORMWATER DISCHARGE OUTFALL (SDO)
MONITORING REPORT
RECEIVE MPLES COLLECTED DURING CALENDAR YEAR: _2017
This monitoring report shall be received by the Division no later than 30 days
SEP 1 �J from the date the facility receives the sampling results from the laboratory.)
FACILITY NAME _Weaver Parts and U Pull CENTRAL FILES ' COUNTY Union
�.
PERSON COLLECTING SAMPLE(S) _Dave Barzoff ` PHONE NO. L704_)_218-3347
CERTIFIED LABORATORY(S) TestAmerica Pensacola Lab # 314
Lab # PLEASE REMEMBER TO SIGN ON THE REVERSE 4
Part A: Stormwater Benchmarks and Monitoring Results
For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within
30 days of the end of that period to comply with permit reporting requirements.
Outfall
No.
Date
Sample Collected,
mo/dd/year
Total
Rainfall,
inches
00400
00S30
----
77023
01051
78141
pH,
Standard
Units
Total Suspended
Solids (TSS),
mg/L
Non -polar
O&G/TPH
(Method 1664
SGT HEM), mg/L
Ethylene Glycol,
mg/L
Lead, Total
Recoverable,
mg/L
Total Toxic
Organics3,
mg/L
Benchmark
-
-
6.0 — 9.01
100/50z
i5
8,000
(Tiers 2 and 3)
0.03
1.0
001
IN-
Exempt
002
Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General
Permit.
1See if pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark
range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented
to demonstrate background concentrations were below the benchmark pH range of 6-9.
zSee General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters.
3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122.
Form SW U-251, last revised October 25, 2012
Page 1 of 2
SfORMWATER DISCHARGE OUTFALL (SDO)
MONITORING REPORT
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent
management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the
discharger shall sign the following certification statement:
Solvent Management Plan Certification Statement
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I
certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent
management planincluded in the Stormwater Pollution Prevention Plan."
Name (Print name)
Title (Print title)
Signature
Mail Original and one copy to:
Division of Water Quality
Attn: Central Files
1617 Mail Service Center
North Carolina 27699-1617
Date
0
O
"i certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that tyreare gnficant penalties for submitting false information, Including the possibility of fines and imprisonment for knowing violations."
(Signature of Pere or
9 to 1-1
(Date")
Form SWU-251, last revised October25, 2012
Page 2 of 2
STORMWATER DISCHARGE OUTFALL (SDO)
MONITORING REPORT
CERTIFICATE OF COVERAGE NO.- NCG100 2.19 SAMPLES COLLECTED DURING CALENDAR YEAR: 2017
(This monitoring report shall be received by the Division no later than 30 days
from the date the facility receives the sampling results from the laboratory.)
FACILITY NAME Weaver Parts and U Pull COUNTY Union
PERSON COLLECTING SAMPLE(S) Dave Barzoff PHONE NO.704-218-3347
CERTIFIED LABORATORY(S) TestAmerica Pensacola Lab # 314
Lab # P[Ifkfj
EMBER TO SIGN ON THE REVERSE
Part A: Stonmwater Benchmarks and Monitoring Results MAR 13 2018
For sampling periods with no discharge, you must submit this discharge mong1 b n � '1M' fng "No Flaw" or "No Discharge" within
30 days of the end of that period to comply with permit reporting requirements.
Outfall
No. i
Date
Sample
Collected,
mo/dd/year
Total
Rainfall,
inches
00400
00530
- - - -
77023
01051
78141
pH,
Standard
Units
Total Suspended
Solids (TSS),
mg/L
Non -polar
O&G/TPH
(Method 1664
SGT-HEM), mg/L
Ethylene Glycol,
mg/L
Lead, Total
Recoverable,
mg/L
Total Toxic
Organia3,
mg/L
Benchmark
-
-
6.0 — 9.0�
100/50,
15
8,000
(Tiers 2 and 3)
0.03
1.0
001
07/20/2017
1.0
7.0
3.3
< 12
0.0029
Exempt
002
Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General
Permit.
ISee If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark
range is the pH of the precipitation (within instrument accuracy) instead of 6.S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented
to demonstrate background concentrations were below the benchmark pH range of 6-9.
2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters.
3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table It of Chapter 40 Code of Federal Regulations (CFR) Part 122.
Form SWU-251, lost revised October25, 2012
Page 1 of 2
SfORMWATER DISCHARGE OUTFALL (SDO)
MONITORING REPORT
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent
management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the
discharger shall sign the following certification statement:
Solvent Management Plan Certification Statement
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I
certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent
management plan included in the Stormwater Pollution Prevention Plan."
,jVe [ 4970)�' p
Name (Print name) T
Title Pr'
917116
Signature Date
Mail Original and one copy to:
Division of Water Quality
Attn: Central Files
1617 Mail Service Center
North Carolina 27699-1617
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that there are significant pgapIfigsJor submitting false information, including the possibility of fines and imprisonment for knowing violations."
I
r Designee)
f7 1�
( Date)
Form SWU-251, last revised October25, 2012
Page 2 of 2
STORMWATER DISCHARGE OUTFALL (SDO)
MONITORING REPORT
CERTIFICATE OF COVERAGE NO. NCG100 219 RECEIVEOMPLES COLLECTED DURING CALENDAR YEAR: 2016
MAR 2 7 201 l(This monitoring report shall be received by the Division no later than 30 days
from the date the facility receives the sampling results from the laboratory.)
CENTRAL FILES
FACILITY NAME _ Weaver Parts and U Pull DWR SECTION COUNTY Union
PERSON COLLECTING SAMPLE(S) _N/A PHONE NO. (_704_j218-3347
CERTIFIED LABORATORY(S) N/A Lab #
Lab # PLEASE REMEMBER TO SIGN ON THE REVERSE
Part A: Stormwater Benchmarks and Monitoring Results
For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within
30 days of the end of that period to comply with permit reporting requirements.
Outfall
No.
Date
Sample Collected,
mo/dd/year
Total
Rainfall,
inches
00400
00530
- - - -
77023
01051
78141
pH,
Standard
Units
Total Suspended
Solids (TSS),
mg/L
Non -polar
O&G/TPH
(Method 1664
SGT-HEM), mg/L
Ethylene Glycol,
mg/L
Lead, Total
Recoverable,
mg/L
Total Toxic
Organics3,
mg/L
Benchmark
-
-
6.0 — 9.01
100/502
15
8,000
(Tiers 2 and 3)
0.03
1.0
001
Exempt
002
Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General
Permit.
1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark
range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented
to demonstrate background concentrations were below the benchmark pH range of 6-9.
2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters.
3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122.
Form SW U-251, last revised October 25, 2012
Page 1 of 2
STORMWATER DISCHARGE OUTFALL (SDO)
MONITORING REPORT
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent
management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the
discharger shall sign the following certification statement:
Solvent Management Plan Certification Statement
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I
certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent
management plan included in the Stormwater Pollution Prevention Plan."
L y-r &RzaFr
Nar-76-Wc414
e (Print name)
C
Title (Print title)
6 � L14, i
Signat�uro Date
Mail Original and one copy to:
Division of Water Quality
Attn: Central Files
1617 Mail Service
Center
Raleigh, North Carolina 27699-1617
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
/]
(Date)
Form SW U-251, lost revised October 25, 2012