Loading...
HomeMy WebLinkAboutNCG030283_COMPLETE FILE - HISTORICAL_20100208STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /v DOC7YPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ a?ZII 0 t%al%f YYYYMMDD Allocco, Marcia From: Allocco, Marcia Sent: Monday, February 08, 2010 3:39 PM To: 'Terry Carter' Cc: 'Eubanks, Ron' Subject: Additional Sampling Terry, just wanted to document my site visit last Thursday (2/4/10) and the additional sampling that I requested as part of your Tier Il response under NCG030283. I wanted to thank you for your assistance during the visit and for your actions to date to reduce the lead concentrations in the stormwater released from the Dixon Quick Coupling site. After reviewing your site it was agreed by all parties present that the following locations would be sampled for lead in an attempt to determine the source of the elevated lead in the stormwater on site. • Catch basin behind the warehouse (2 samples) — this catch basin appears to be at the head of the drainage line that runs through "brass alley". There were two pipes that discharge to this catch basin. One appears to be a roof drain line and the other pipe's source was not evident and could be adding stormwater flow from off -site. Both pipes should be sampled. Sampling of this catch basin would give a "background" concentration for lead before entering "brass alley". • Discharge pipe at the end of "brass alley" (1 sample) — this sample should show how much lead is added to stormwater from the brass stored in this area • Brass storage (1 sample) -- this sample is to be of water poured over the brass rods stored in brass alley" to ascertain how much lead might be shed from -the storage of this material outside and exposed to stormwater. • Current outfall (2 samples) — it was noted during the inspection that there are two pipes that contribute stormwater to the current "outfall" that is being sampled on site. One pipe comes from the parking lot and "brass alley" and the other collects stormwater from the drainage line that runs through the main Dixon manufacturing area. This sample should identify if one of these areas is contributing more lead than the other to stormwater discharges from the site During the site visit the compliance status of Atlantic Scrap and Processing facility on Atando Avenue (across the street) was raised. After some research it was determined that this facility is currently covered under Certificate of Coverage NCG200351, Wholesale Trade of Metal Waste and Scrap stormwater discharges. Our database indicates that the facility was inspected for compliance with their NPDES permit in early 2008 by Ms. Heather Sorensen and Ms. Erin Hall of the Charlotte -Mecklenburg Stormwater Services Group (Mr. Ron Eubanks's co-workers) and Atlantic Scrap and Processing was found to be compliant with this general permit at the time of the inspection. Please forward the stormwater samples results when you get them so we can discuss and determine any additional sampling/measurements at Dixon Quick Coupling. Regards, Marcia Marcia Allocco, MS - Environmental Chemist NC Dept. of Env. & Natural Resources (NCDENR) Division of Water Quality - Surface Water Protection Group 610 East Center Ave., Suite 301, Mooresville, NC 28115 Ph: (704) 663-1699 Fax. (704) 663-6040 Please note: my e-mail address has changed to marcia.allocco(bncdenr.aov E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Allocco, Marcia From: Eubanks, Ron [Perry.Eubanks@mecklenburgcountync.gov) Sent: Thursday, February 04, 2010 4:20 PM To: Terry Carter Cc: cmccabe@dixonquickcoupling.com; sclark@dixonquickcoupling.com; Allocco, Marcia Subject: Dixon Quick Coupling - Tier Two Monitoring Terry, After our meeting earlier today, Marcia and I inspected the adjacent property. From the inspection, we did not identify any storm drain inlets other than the one large catch basin adjacent to the fence that is covered with vegetation and underbrush. There was an uncovered scrap metal dumpster on the property, but it was empty. There were no other obvious indicators of lead contamination observed on the property. As we discussed during the meeting, please plan to collect storm water samples for lead from the five (5) locations identified during the inspection meeting.. Please send me an e-mail or contact me at (704) 336-5446, if you have any questions or need additional information regarding this matter. Thanks again to you, Crystal, and Scott for your help with the Tier Two storm water monitoring inspection. Have a good evening. Ron Eubanks Environmental Specialist Mecklenburg County Water Quality Program 700 North Tryon Street Charlotte, North Carolina 28202 Phone: (704) 336-5446 Fax: (704) 336-4391 E-mail: Perry. Eubanks(cDMecklenburgCountyNC.gov P_ P-A m wm m-m W, lop, Ir A. 1` 41 II B it CID.. VA ('r omm CLOX am 0.9t cr PILL I P** -7- 60 A 10 OR IL NO 7 ab vil 7 777711. It ftle 32 123 `_ -, a X '=A VIA -.4 Apr- I _c .1 C."rou Pod L)ght P*I* "PLO =I Ptft Nw -Now V Tf 9 j 30 10 30 10 15 30 10 30 30 10 30 30 30 10 10 15 15 Is 30 i 11 30 10 30 30 150 30 15 15 15 !YJ 23 2z 1'4, _5 Z-13 1D C-33 120 E-35 120 E-69 85 HD-1 5 120 E-67 125 E-82 120 E-81 85 E-60 120 9-56 85 E-80 150 E-218 85 E-62 E-79 150 E-78 120 E-68 85 E-64 85 C-73 250 E-74 250 E-75 250 PC— (12 PC- HD- 03 120 HD- HD-1 4 120 HD-22 120 E 30 N; 02 '2L MP-03 250 NP-04, 250 NP-05 __250— 14YOR-Ajj -1 Nt SCALE: I'-4d ---- --- UP,, KIP. j NOTE (TI) DUKE POWER TRANSFORMER- 1000 XVA COMPRESSOR ROOM .S3EFr- AIR CONDENSATE (55 gal. DRUM) (D HYDRAULIC OIL DRUM (55 gat) AOL. "AET.A I- H;-iEEN O COOLANT STORAGE TOTE (2 0 275 gal) '4A7'-f' A OIL DRUM STORAGE �E AREA AND EMPTY DRUMS (MOP WATER, NEW A SUMP PUMP (225 go]. MOBILE TANK) AND M')Fl) CUTTING FLUID) NF-WAJSFD OIL (T,) DUKE POWER TRANSFORMER (1000 GAL TANK) @ NEW/USED OIL (500 GAL. TANK) NEW/USED OIL TANK, 500 GAL. APE NEW/USED OIL TANK, 500 GAL :;!'P;.P AL E4 1_ x "'(4 \ x Y. cr. tfi SPENT MEVAL SHEFN (56 gd. DRUMS) SCRA"' ;sue :ilj- ma`= £Gfz Y —INZ, TJF l;A." NOT A LL-CATIQN> cit- A0 -A 1_01,.4_1i("._t �70i�.m SEWERS LCK-FL'F�n UNEq:p ShicXe." 2.',UNFAh7 AND SURVEY PY1 SFRVI,--F 5. "BLUE' DENOTES SPCC. REGULATED OIL - ;; . VID '_�E*-JTEE �, �__, V HAS eEFN Ffmo- , TIE t5 A N G" sew I APPW40 BY I DRAm uf. A 1NOW& Bara m1w I 11Dc I u—N T% 20M I:J&Z% Q-.iw mm=umm I J4 Allocco, Marcia From: Eubanks, Ron [Perry.Eubanks@mecklenburgcountync.gov] Sent: Monday, December 07, 2009 5:16 PM To: Pickle, Ken Cc: Georgoulias, Bethany; Bennett, Bradley; Allocco, Marcia Subject: RE: Dixon Quick Coupling - NCG030306 Ken, I apologize for the confusion. There was a concrete storm sewer pipe that drained storm water runoff from the scrap metal dumpster area at the site. The paved areas around the dumpsters were cleaned and a structural canopy was installed over the scrap metal dumpsters. To verify if the control measures were successful, clean water was discharged into the storm sewer at the site from a water truck to simulate a storm event. The sample collected from the water truck was non -detect for lead; however, the samples collected from the outfall were above the benchmark. In other words, clean water discharged into the storm sewer at the site was still above the benchmark for lead at the outfall. To address the possibility of residual lead contamination in the storm sewer at the site, the concrete pipe was replaced with HDPE pipe. Please send me an e-mail or contact me at (704) 336-5446, if you have any additional questions or concerns regarding this matter. Thank you, Ron Eubanks Environmental Specialist Mecklenburg County Water Quality Program 700 North Tryon Street Charlotte, North Carolina 28202 Phone: (704) 336-5446 Fax: (704) 336-4391 E-mail: Perry. Eubanks(&MecklenbumCountyNC.gov From: Pickle, Ken ( mailto: ken. pidde@ncdenr.gov] Sent: Monday, December 07, 2009 4:32 PM To: Eubanks, Ron Cc: Georgoulias, Bethany; Bennett, Bradley; Allocco, Marcia Subject: RE: Dixon Quick Coupling - NCG030306 Ron, Just curious really. What am I missing here? A concrete pipe was a potential source for lead contamination? What don't I understand about these circumstances? Ken From: Eubanks, Ron [mailto: Perry. Eubanks@mecklenburgcountync.gov] Sent: Monday, December 07, 2009 3:46 PM To: Pickle, Ken Cc: Georgoulias, Bethany; Bennett, Bradley-, Allocco, Marcia Subject: RE: Dixon Quick Coupling - NCG030306 Ken, Thank you for the information. I will discuss your comments with Mr. Terry Carter (Dixon Quick Coupling), who is currently preparing the Tier 2 response. Dixon Quick Coupling has not installed any structural BMPs to treat lead in the storm water runoff, but they have installed a structural canopy over the scrap metal dumpsters and they have replaced a section of the storm water concrete pipe near the outfall that was a possible source of the lead contamination. As I indicated in the earlier e-mail, Dixon Quick Coupling is also investigating possible off -site sources of lead. Thanks again for your help. Please send me an e-mail or contact me at (704) 336-5446, if you have any questions or need additional information regarding this matter. Have a good evening. Ron Eubanks Environmental Specialist Mecklenburg County Water duality Program 700 North Tryon Street Charlotte, North Carolina 28202 Phone: (704) 336-5446 Fax: (704) 336-4391 E-mail: Pens.Eubanks(&Mecklenbu[gCountyNC.(I From: Pickle, Ken [mailto:ken.pickle@ncdenr.gov] Sent: Monday, December 07, 2009 9:17 AM To: Eubanks, Ron Cc: Georgoulias, Bethany; Bennett, Bradley; Allocco, Marcia Subject: RE: Dixon Quick Coupling - NCG030306 Hi Ron, nice to hear from you again. Thanks for your help with Wallace Farm in 2008. I've inserted comments in your note. unfortunately, we don't have a substantial data base on Tier 2 responses, yet. We do have some few facilities that have notified us of a Tier 2 status, and I think one or two facilities that have accumulated the four exceedences that would trigger a DWQ/Meck site visit and determination of feasible responses. But we don't have anything approaching a 'database', or even an expectation of proper responses, yet. See my further comments below. Bethany, any additional help for Ron and Marcia? Ken From: Bennett, Bradley Sent: Wednesday, December 02, 2009 4:13 PM To: Georgoulias, Bethany; Pickle, Ken Subject: FW: Dixon Quick Coupling - NCG030306 Hey Guys I think you can help provide some feedback to Ron on these issues. Thanks BB Bradley Bennett Stormwater Permitting unit NC Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone: (919) 807-6378 Fax: (919) 807-6494 Email: bradley.bennett@nedenr.gov (New Email Address) Web: http://h2o.enr.state.nc.us/su/index.htm Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Eubanks, Ron [mailto: Perry. Eubanks@mecklenburgcountync.gov] Sent: Wednesday, December 02, 2009 3:54 PM To: Bradley Bennett Cc: Allocco, Marcia; terry@dixonquickcoupling.com Subject: Dixon Quick Coupling - NCG030306 Hey Bradley, I conducted a Storm Water Compliance Evaluation Inspection at Dixon Quick Coupling (332 Atando Avenue, Charlotte) on March 27, 2009. Since the inspection, I have been working with Mr. Terry Carter (Dixon Quick Coupling) to address storm water concerns at the site. As you may be aware, Dixon Quick Coupling has exceeded their benchmark monitoring requirement for lead and they are currently preparing a Tier Two Response. From inspections at the site and meetings with Mr. Terry Carter, Dixon Quick Coupling has implemented both structural and nonstructural storm water control measures to address the elevated concentrations of lead in the storm water runoff from the site. So, presumably the source of the lead is not a mystery, right? Dixon knows that lead is on their site because it's in their manufacturing process somewhere, right? And presumably the control measures are primarily avoiding exposure, rather than treatment? From a recent storm water monitoring event, samples were collected at multiple locations on the property. There is some sheet flow from the adjacent property that drains onto the Dixon Quick Coupling property. Is there some suspicion that lead is coming onto the Dixon site from another source? If so, our general approach would be that Dixon is responsible for pollutants generated by them, or their predecessors, on their site: but they're not responsible for pollutants generated by other folks. The Mecklenburg County Water Quality Program will continue to work with NCDENR-Mooresville Regional Office to identify potential sources of lead at the Dixon Quick Coupling site and other properties in the surrounding watershed_ In the meantime, I would like to get some information from you or your staff on how similar facilities have addressed exceedences of their benchmark monitoring requirements. For Ter Two, facilities are required to shift into monthly sampling, and attempt again to evaluate the feasibility of some control response. We have limited data to date. None on lead, as far as I know (This Tiered approach is so new that we generally pay attention when someone actually installs a control measure in response to the analytical results, and I'm not aware of any on lead, yet.) But, again, it's usually cheaper for the permittee to control exposure, rather than install BMPs. In general folks prefer limiting exposure to finding the site space to accommodate a new structural BMP —generally it's cheaper, and it doesn't require taking up part of the available space on site. As long as the permittee is in Tier One, or Tier Two, the initiative is on them to do what they can to meet the benchmarks. When they hit four exceedences for one parameter at one outfall, their obligation is to contact DWQ/Meck and we will help them decide what makes sense as far as getting the pollutant discharge under control, if feasible. It sounds like they have shortcut that process a little bit, and have got you involved early. That's fine, of course. — Are there many facilities covered under General Permit No. NCGO30000 that have exceeded the benchmark value for lead. I don't have time this week or next to research this for us. My time is spoken for over that period. I'll be glad to help after Christmas. If a facility is not able to meet the analytical monitoring requirements of the General Permit, should they apply for an Individual Permit? Maybe, but not necessarily. Let's attempt the Tier One response, and the Tier Two response, and see what success they have. If they continue on and accumulate four exceedences, then an individual permit is an option, but in the circumstances as I understand them at Dixon, what benefit would that be? They'd still have a lead benchmark that they can't meet. 5o, while I can imagine circumstances at Dixon that would lead us to require an individual permit, we'd first rather play out the procedure, go through the steps, and see what progress we can make with them still under the General Permit. Because: The new NCG03 General Permit allows DWQ the freedom to direct control measures: previously we more or less implemented our program by only requiring BMPs within the framework of an Individual Permit. But now, with the new template for General Permits, we can accomplish that within the General Permit. Please send me an e-mail or contact me at (704) 336-5446 to discuss at your convenience. Thank you. Have a good evening. Ron Eubanks Environmental Specialist Mecklenburg County Water Quality Program 700 North Tryon Street Charlotte, North Carolina 28202 Phone: (704) 336-5446 Fax: (704) 336-4391 E-mail: Perry. EubanksC@MecklenburqcountyNC.gov Allocco, Marcia From: Eubanks, Ron [Perry.Eubanks@mecklenburgcountync.gov] Sent: Monday, December 07, 2009 3:59 PM To: Allocco, Marcia Cc: Pickle, Ken; Georgoulias, Bethany; Bennett, Bradley Subject: RE: Dixon Quick Coupling - NCG030306 Hey Marcia, In addition to some structural controls, Dixon Quick Coupling has also implemented some housekeeping measures such as routine parking lot sweeping at the site. Please let me know if you want to schedule a follow-up site inspection at Dixon Quick Coupling, after the Tier 2 response is completed. Please send me an e-mail or contact me at (704) 336- 5446, if you have any questions or need additional information regarding this matter. Thank you. Have a great week! Ron Eubanks Environmental Specialist Mecklenburg County Water Quality Program 700 North Tryon Street Charlotte, North Carolina 28202 Phone: (704) 336-5446 Fax: (704) 336-4391 E-mail: Pent'.Eubanks(c)Mecklenbu[gCountyNC.yov From: Allocco, Marcia fmailto:marcia.allocco@ncdenr.gov] Sent: Monday, December 07, 2009 9:46 AM To: Pickle, Ken; Eubanks, Ron Cc: Georgoulias, Bethany; Bennett, Bradley Subject: RE: Dixon Quick Coupling - NCG030306 Galvan in Cabarrus County had exceeded the lead numbers for NCG030000 and they had much lower and compliant numbers after some "housekeeping" Marcia From: Pickle, Ken Sent: Monday, December 07, 2009 9:17 AM To: Perry.Eubanks@meddenburgcountync.gov Cc: Georgoulias, Bethany; Bennett, Bradley; Allocco, Marcia Subject: RE: Dixon Quick Coupling - NCG030306 Hi Ron, nice to hear from you again. Thanks for your help with Wallace Farm in 2008. I've inserted comments in your note. Unfortunately, we don't have a substantial data base on Tier 2 responses, yet. we do have some few facilities that have notified us of a Tier 2 status, and I think one or two facilities that have accumulated the four exceedences that would trigger a DWQ/Meck site visit and determination of feasible responses. But we don't have anything approaching a `database', or even an expectation of proper responses, yet. See my further comments below. Bethany, any additional help for Ron and Marcia? Ken From: Bennett, Bradley Sent: Wednesday, December 02, 2009 4:13 PM To: Georgoulias, Bethany; Pickle, Ken Subject: FW: Dixon Quick Coupling - NCG030306 Hey Guys I think you can help provide some feedback to Ron on these issues. Thanks BB Bradley Bennett Stormwater Permitting Unit NC Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone: (919) 807-6378 Fax.(919) 807-6494 Email: bradley.bennett@ncdenr.gov (New Email Address) Web: http://h2o.enr.state.nc.us/su/index,htm Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Eubanks, Ron [mailto:Perry.Eubanks@mecklenburgcountync.gov] Sent: Wednesday, December 02, 2009 3:54 PM To: Bradley Bennett Cc: Allocco, Marcia; terry@dixonquickcoupling.com Subject: Dixon Quick Coupling - NCG030306 Hey Bradley, conducted a Storm Water Compliance Evaluation Inspection at Dixon Quick Coupling (332 Atando Avenue, Charlotte) on March 27, 2009. Since the inspection, I have been working with Mr. Terry Carter (Dixon Quick Coupling) to address storm water concerns at the site. As you may be aware, Dixon Quick Coupling has exceeded their benchmark monitoring requirement for lead and they are currently preparing a Tier Two Response. From inspections at the site and meetings with Mr. Terry Carter, Dixon Quick Coupling has implemented both structural and nonstructural storm water control measures to address the elevated concentrations of lead in the storm water runoff from the site. So, presumably the source of the lead is not a mystery, right? Dixon knows that lead is on their site because it's in their manufacturing process somewhere, right? And presumably the control measures are primarily avoiding exposure, rather than treatment? From a recent storm water monitoring event, samples were collected at multiple locations on the property. There is some sheet flow from the adjacent property that drains onto the Dixon Quick Coupling property. Is there some suspicion that lead is coming onto the Dixon site from another source? If so, our general approach would be that Dixon is responsible for pollutants generated by them, or their predecessors, on their site: but they're not responsible for pollutants generated by other folks. The Mecklenburg County Water Quality Program will continue to work with NCDENR-Mooresville Regional Office to identify potential sources of lead at the Dixon Quick Coupling site and other properties in the surrounding watershed. In the meantime, I would like to get some information from you or your staff on how similar facilities have addressed exceedences of their benchmark monitoring requirements. For Tier Two, facilities are required to shift into monthly sampling, and attempt again to evaluate the feasibility of some control response. We have limited data to date. None on lead, as far as I know (This Tiered approach is so new that we generally pay attention when someone actually installs a control measure in response to the analytical results, and I'm not aware of any on lead, yet.) But, again, it's usually cheaper for the permittee to control exposure, rather than install 13MPs. In general folks prefer limiting exposure to finding the site space to accommodate a new structural BMP— generally it's cheaper, and it doesn't require taking up part of the available space on site. As long as the permittee is in Tier One, or Tier Two, the initiative is on them to do what they can to meet the benchmarks. When they hit four exceedences for one parameter at one outfall, their obligation is to contact DWQ/Meck and we will help them decide what makes sense as far as getting the pollutant discharge under control, if feasible. it sounds like they have shortcut that process a little bit, and have got you involved early. That's fine, of course. Are there many facilities covered under General Permit No. NCG030000 that have exceeded the benchmark value for lead. don't have time this week or next to research this for us. My time is spoken for over that period. I'll be glad to help after Christmas. If a facility is not able to meet the analytical monitoring requirements of the General Permit, should they apply for an Individual Permit? Maybe, but not necessarily. Let's attempt the Tier One response, and the Tier Two response, and see what success they have. If they continue on and accumulate four exceedences, then an individual permit is an option, but in the circumstances as I understand them,at Dixon, what benefit would that be? They'd still have a lead benchmark that they can't meet. 5o, while I can imagine circumstances at Dixon that would lead us to require an individual permit, we'd first rather play out the procedure, go through the steps, and see what progress we can make with them still under the General Permit. Because: The new NCG03 General Permit allows DWQ the freedom to direct control measures: previously we more or less implemented our program by only requiring BMPs within the framework of an Individual Permit_ But now, with the new template for General Permits, we can accomplish that within the General Permit. Please send me an e-mail or contact me at (704) 335-5445 to discuss at your convenience. Thank you. Have a good evening. Ron Eubanks Environmental Specialist Mecklenburg County Water Quality Program 700 North Tryon Street Charlotte, North Carolina 28202 Phone: (704)336-5446 Fax: (704) 336-4391 E-mail: Perry. Eubanks �MecklenbumCuntyNC.gov Tier One and Tier Two Response Permit NCG030000 The Right ConnectionTM Dixon Quick Coupling A Member of the Dixon Group DEC 19 2009 December 14, 2009 Terry Carter Facilities Engineer 1.0 Introduction Dixon Quick Coupling is a manufacturer of Quick Disconnect Couplings_ These couplings are made from a variety of materials including brass, steel and stainless steel. Dixon Quick Coupling is located at 332 Atando Avenue Charlotte North Carolina on approximately 4.2 Acres_ Dixon Quick Coupling's facility has approximately 77,835 square feet under roof. Beginning in February 2009, Dixon Quick Coupling began its storm water management practices depicted in General Permit NCG03000. It became apparent that we are exceeding our benchmark goal in total lead. Working together with Aware Environmental, located in Charlotte, we immediately began taking measures to correct this issue. Ron Eubanks with the Mecklenburg County Storm Water Quality Program came to our facility to conduct a storm water compliance evaluation. Dixon Quick Coupling passed this inspection knowing that we were expected to work towards meeting our total lead permit threshold. We worked closely with Ron, and at times ran split storm water samples that were tested by the City of Charlotte, producing results at or near the result levels analyzed by Pace Analytical. Pace Analytical is a local laboratory located in Huntersville, NC used by Dixon Quick Coupling in the testing of storm water. The following pages are details of measures taken to reduce total lead. 2.0 Testing and Control Measures • February 27, 2009 Ist qualifying storm event Samples were taken by Dixon Quick Coupling and tested by Pace Analytical for Ph, Total Lead, Total Suspended Solids, Oil and Grease • March 06, 2009 Received test results listed below for the storm event dated February 27, 2009 Table 1 Outfall Date Total Suspended Lead, Oil and No. Collected Solids pH Total Grease No. 2 1 Feb 27, 2009 108 m 7.9 .314 m /L 1 16.7 m /L Dixon Quick Coupling knowing that we were above our benchmarks on total lead took the following steps to correct the issue: March 16, 2009 • Dixon Quick Coupling excavated the area adjacent to the storm drain and added rock around the perimeter of the shipping area to alleviate the soil erosion in those areas. Bales of wheat straw were added to the entrance of the storm drain to catch any foreign debris before entering the storm drain. • March 21, 2009 Dixon Quick Coupling had the entire shipping area pressure washed, having all residue properly removed from the premises. • April 30, 2009 Dixon Quick Coupling purchased a building to cover and contain the scrap chip dumpsters stored in the shipping area. • July 28, 2009 1st qualifying storm event after improvement activities were complete. Samples were taken by Dixon Quick Coupling and tested by Pace Analytical for Ph, Total Lead, Total Suspended Solids, Oil and Grease • August 5, 2009 Received test results listed below for the storm event dated July 28, 2009 Table 2 Outfall Date Total Suspended Lead, Oil and No. Collected Solids pH Total Grease No.2 July 8, 2009 4.2 mg/L 6.0 .101 mg/L I None detected Dixon Quick Coupling knowing that we remained above our benchmarks on total lead took the following steps to correct the issue. • August 24 2009 Dixon Quick Coupling performed a mock storm event. A water truck was hired to bring water to our facility to aid in determining the source of the lead causing us to exceed our total lead benchmark. The process for the aforementioned is as follows: l . The water truck would park within 20 feet from the entrance of the storm drain. 2. The driver of the water truck would start the water draining from his truck. 3 _ A sample was taken directly from the truck. 4. The water from the truck was allowed to follow the path of a normal rain event and another sample was taken from outfall No.2. 5. The sample taken directly from the truck as well as the sample taken from outfall No.2 was tested for total lead by Pace Analytical. Ron Eubanks with the Mecklenburg Division of Water Quality was present for this test and ran split samples that were tested by the City of Charlotte. These test results are listed along with samples tested by Pace Analytical. • August 29, 2009 Received test results listed below for the Mock Storm Event dated August 29, 2009. Table 3 DQC Sampling Outfall No. Date Collected Total Suspended Solids pH Lead, Total Oil and Grease Water Truck August 29, 2009 1 1 None Detected No.2 August 29, 2009 .041 m Table 3 DWQ Sampling Outfall No. Date Collected Total Suspended Solids pH Lead, Total Oil and Grease Water Truck August 29, 2009 None Detected No.2 August 29, 2009 .180 m • September 9, 2009 Dixon Quick Coupling replaced the storm drain from the entrance to the junction box where storm water samples are taken_ The floor was also re -poured to help in the reduction of lead in the drain. • September 23, 2009 Dixon Quick Coupling performed another mock storm event. Samples were taken and tested for Total Lead by Pace Analytical. Ron Eubanks with the Mecklenburg Division of Water Quality was present for this test and ran split samples that were tested by the City of Charlotte. These test results are listed along with samples tested by Pace Analytical. • September 25, 2009 Received test results listed below for the Mock Storm. Event dated September 23, 2009, Table 4 DQC Sam lin Outtall No. Date Collected Total Suspended Solids pH Lead, Total Oil and Grease Water Truck September 23, 2009 None Detected No.2 September 23, 201 .145 Table 4 DWQ SampUmg Outfall No. Date Collected Total Suspended Solids pH Lead, Total Oil and Grease Water Truck I September 23, 2009 1 1 1 None Detected No.2 J_September23,200,9 I 1 1 .210 MqAt September 28, 2009 Dixon Quick Coupling moved the brass turnings trailer under the new building to help prevent rain from being filtered through the brass turnings. The shipping area is now being swept twice weekly and any turnings or other particulate found in the shipping area is removed. • October 17, 2009 Dixon Quick Coupling had the entire slipping area pressure washed having all residue properly removed from the premises. • October 22, 2009 Dixon Quick Coupling performed another mock storm event. Samples were taken and tested for total lead by Pace Analytical. • October 26, 2009 Received test results listed below for the Mock Storm Event dated October 22, 2009 Table 5 Outfall No. Date Collected Total Suspended Solids pH Lead, Total Oil and Grease Water Truck October a 2009 None Detected No. 2 October 22, 2009 .056 m • November 10, 2009 1:4 qualifying storm event after further improvements were made. • November 13, 2009 Received test results listed below for the storm event dated November 13, 2009. Table 6 Outfall No. Date Collected Total Suspended Solids pH Lead, Total Oil and Grease No.2 November 10, 2009 102 m 7.5 .314 1 None Detected • As a part of the November 13, 2009 testing, we also sampled storm water coming onto our property from an adjacent property as well as other areas on our property depicted below. These samples were tested for total lead only. Table 7 Outfall No. Date Collected Total Suspended Solids pH Lead, Total Oil and Grease Behind Warehouse November 10, 2009 .0393 mg/L Loading Dock November 10, 2009 .194 m /L Roof at Shipping November 10, 2009 .026 mWL • December 8, 2009 Dixon Quick Coupling performed Tier 11 Stormwater sampling. • Received test results listed below for the Storm Event dated December 8, 2009. Table S Outfall No. Date Collected Total Suspended Solids pH Lead, Total Oil and Grease No.2 December 8, 2009 24.5 mg/L 7.5 .103 mg1L 8.4 mg/L 3.0 Conclusion Dixon Quick Coupling will continue to monitor and to the best of our ability determine the source of lead on the property. General housekeeping along with other potential structural BMP's are being researched. One concern, as referenced in Table 7, refers to a total lead concentration of .0393mg/L which was taken from behind our warehouse of storm water coming from an adjacent property_ This sample also exceeds the current threshold prior to entering the Dixon Quick Coupling property. It appears that the failure to meet the total lead threshold could be complicated by the run off from adjacent properties. Please find enclosed all test reports, as well as before and after pictures of measures taken to become compliant in total lead. Any assistance your office can give in this matter will be greatly appreciated. February 2009 Before Improvements to Shipping Area May 2009 After Improvements to Shipping Area uaxV 2uTddtgs of SJUX anoiduxl WOWS 60OZ �nrugo j r' 7-4 �q M��N ff ,,�. r L':�.1. y. '- � ` i4•.�. �' to � r`I k�� t . r ' '"' { a ``, 'f :• �l �'/ny �' 17�`re ,''u��ar �k•H�' �. t In rui-1,rSlic j - "� D � - w i - +_ + r 4r'r.}- N • \ 0 � �r �" ��Cly !�/"c 4 �' trr�..` ��1�'F ' yo -� _ �y . rs tc � }�r� �y't'��ty�. -I nhm r _•`-L'��'"ACC)+, , M' �jY}.{tip��. u��?4� ' `' ,.,�j'r "-1' Y " ' ` � - �♦. " ; ,yCt`- , + 'rt �j �;Cf,."�" .r � T� "+ �� , ,�.,.•a ,� .p...;.;�w �Kr �'r"�� 1 x.,a „�:' t � � a � r�.. , �s ,,,,� � _ E w� � � .L �l'i.�", a+y_ Yc �"- _ __ Y ti �s•.- Y �a - ,th, e" •r d ; Y r � a - y�` • �A ~�Z c+` S' Sr� ..� 43� i''�4�'. v f-r�. y ''+� '� �-0�9'' - Y o - ^� 1 .. � � `� -tl ''r �hp��;'r8 Ms.-•_Y.'G t. '��_vt'�'+a-.;�v - _ ll/ , _ •. ,f plc ' �,." A,- . Tti Q �•.n . �rL t� s�`tq.. . ' o� err. w .tea �' ' .- '+h.. .::. � , yet 1n .�.. r?� �, -,r �� --_ E, i : ' • °� r e R {4U �L ��. a`y ? `' r ��. � ! .�. .},� � ' 4 � � ar '^ wr � � r� y Dom` .`�•�+,� .%1r,.i •"�' . fo ��. • '}� � � `L� � � S� '��u-- ^fit'-"° y. - �. K, s a� �,�,5. � "� � r^ . ��� �'� � �� \ S tit :� � Y `' ��1 't..' ,?•�--•ti � ���,.',� 1 \ 1� �+.ta+�L y� .} r . �1� Y*.�K� ? O . ty r ''1 i ;;� � ' I Ai �--^ , S _ ..\� • :. � rr''���yy'rrlo�.rY.���•o,�'-" �'.'�T` 1 ��. � , r`I: \ . a. w` +�'� "'i4 +��4^r,, � �7� \c� �-�- '� —'.� •.t '�; � � \ 4 t,� . "TR'»" w� ' _ } � `'V -T' � :•� �- a :� ,,, 1� � �'4.►=L. \�.i"°+71. � �,.r � �1 ,C4C1 �s"�,y�' i '^ � u� + f f- T �r ir�."~��i * .. , f .:� f ��. L l rC, • 4C i - -�� l'aF'��N„j •b y ./'ti y1� �yF� {� .r , �. • � � .� 1 T` � � Yy '•� � 1. ` y _ � •,. .L1r erg 'l 1, L e'-' \ On" 3 t `.� d l ... , �31°% \,� �r : fi' `+� 1 .t��.r„ .`"a �•`. ~1V. fL~:-�� ` �ti. \'��+~y �Z.,.� % c�� ^��y j.7" ;y�s aiibCi,�a.•_e .y ,:J��� ++�tr'`�:���� l�,Ci,�,, .•,�- � .�/;�+•y `.c �S` ` � \ � �_ �.•r,'•'�=v r�.. W1.-t � "y,}��lC•ff r•-�_ 104�y�'.J^tii."\�r � ;c..;1 \ -. f yi ��_at;..y�� �73, �� 'e'ii ® \r _ ; •A_.l.sk :`1` a �� .1',J''� .�. ��,r e �'��,.i14Y �r-wSC-'��� "-\�\.K"ti`J� `}'�-� •�i�' `�l.C' M1vCj�+ t..-`�'.�-i���.•�''�•�4: �7 ; ..,F , ,�` -� �`aa.► '�`,, !. � ����:++�*�; .� yam' � � �����.,� � "c' k '. v t � o- . �r i � �•e.�r,sr '�' - s<t 'V ,S ' •� r. y �'+.....t i, �`. 1, 4�i'7i=t.� \`},.'�\`� 4�-� : ?, _ `� �' � L��:. ' '' `,i '!.y^. `wC�� �.p.K'a�y� j 4 � a.a` ,�' n' "' �'' � t- �3 � �'�" '+r,`4 � - _..ram-- e %...�' - �� � -• �'. � �°�• •�a` ,.��"��, '''��`Q'' �"r� *~�-��)���.�tt`��-"�� � 'a »- t f_ •1�.�� . k i. ��• -�"�`;Y„'J'-��.a T` -� :uk:...••r:�"�°�i "��4,.�?+a •y�� ya..1.� '..; �"C i ���•• a � • �``C, � ``- >�` .;..� �. . - .' `l �%�11p"\ � 'a';��;t1'�r�4 i� � °� � Y•'�t•4:'� �- ��t i�"�'S.',,-�t'1`ts "i�4 �C .:` ?- �L .=a.. f",t..�, . `-..u.. �,�,//4�_..',�.._�'f,�y�'-,� \• `.�`Z`': gyp'' 4 1 • .tit1" 44ti�'�s'�'rr Y `i "" _ .r' _ � .fc.✓ � a.��r�7� �I�J+ �i! ^. �:�f« ar4�� r�r��. �� `..�+� � £:".L��.��•=``'--r~'L," �{�4i eJCLisd • _i{J'ij�M," ,�3u."'-,a�-'"� ,' ,!, tit�..f1 �'M,,*Y•y-�'wxs `��'. ,. :i. y � A,�"�:r` j7'�r4'"kY'�-i•.1? �At�l/���_ A , �.., Sprly 5.. ,7�3.�{l ,+,��.t{F•154 .. Ls..� ..._ .s. ?`•:'��'?%• r �::. •3�'��.`�!_� id :4:#'.. �ai��:'�Cir3c'_i1�-a+'6 ��T;h�i.�wt�"5':c_.�e•�.�. J^ r. _+�:.'���M".^. �..}-;�"C�.Y_ 4-L 'x','� I.i n c � gjI i^-{^sc`Iy� �e'Y1r ,�.' v-. t.._'! J. cT Tr^ ^:C,� _-+'.�_ •A . ,r _'i•M 4-7 K� kf aFi"eY"��•"A .'� 'k,•�c �; `,.4 7�', ✓�� . aw^4 :T,.iw• '� * -r' : .. �_•--f,l ..,._r.. _�.. fi��"`•�;�s _. ;i~ r-�'^�`�� t- �' �. 'J' .� - 4..1.E � �'--_.y, ,� ar rf�.k�r:Z..�-� — 1 VIA m aceAnalyfical- warai.1sciolallaxam CHAIN -OF -CUSTODY / Analytical Request Document The Chain -of -Custody 13 a LEGAL DOCUMENT. All relevant fields must be Completed accurately. Section A Section 8Section C Pop: Of Required Client Information; Required Pm)M Information: hyalce Informatlow Report To: Attention; ComT, 1178905 ,_ _J K �q,,JQ,,r,5 Ca,ot kick" br edge- AddlU Copy To: cam Name KL N "042 0%Q Address: F NPDEs r GROUND WATER r— DRINKING WATER r— LIST r— RCRA OTHER Email To: Purchase Order Na.: Pace Quote Phone: "ad Name: Q.JICK co,"Ril-11 Pam Project Manager. t, Requested Due DstwJTAT- 1proled Number. acl b Pam Prom N. Section 0 Matrix Codes COLLECTED "UftdCU@ni Infomw*n MURIX I CODE 1 Preservatives DrinklingWater DW 8 water WT Waste Water Ww COMPOSITE START COMPOSITE ENDIGf" Product P Soll/Solld SL SAMPLE ID Oil of. ps WP (A-Z. 0-9 1,.) Air AR Sample lDs MUST BE UNIQUE Tlasue TS UJI IM a4w w Other OT 8 Ilk rN 0 2 DATE TIME I DATE TIME I A x z z Pace Project NOJ Lab I.D. 'A lienDly. 10.0,4 Al K III ylip gS ADDIrij: 'Ail SAMPLE CONDITIONS I , IeR =lug* Ft F z .112461 1� :00 C-6 I j,� 0 10b ju Q ORIGINAL .M CL 11 I'll a PRINT Name of SAMPLER. V f E DATE Stoned SIGNATURE of SAMPLER: -1, X-1 (MM/Dorm: 0 I CA 19 'Important Note: By signing this form you are noDeptino Pace's NET 30 day payment term and monasino to late rharoes of 1.6% oar month for any involle not onto WOW 30 daysNI-1— F-ALL-U-wurevw. i9-may-zuu7 11!; eAnalytical' I i Client u ' 01 - Courier: ❑ Fed Ex ❑ UPS ❑ USPSP Client ❑ Commercial ❑ Pace Other Custody Seal on Cooler/Box Present: ❑ yes Wno Seals intact: ❑ yes Ono Packing Material: ❑ Bubble Wrap j"ubble Bags ❑ None ❑Other Thermometer Used T060 Type of Ice: (-Vi)t Blue None --- -famples on ice, cooling process has begun Cooler Temperature U , 'i Temp should be above freezing to 6'C Biological Tissue is Frozen: Yes No NIA Date and itiats of pers examining conten Comments: Chain of Custody Present: At iYes ❑No ❑NIA i. Chain of Custody Filled Out: Byes ❑No ONIA 2. Chain of Custody Relinquished: BTes ❑No ❑NIA 3_ Sampler Name & Signature on COC: s ❑No ❑NIA 4. Samples Arrived within Hold Time: tJres ❑No ❑NIA 5. Short Hold Time Analysis (<72hr): ❑Yes .Ono ❑NIA 6. Rush Turn Around Time Requested: ❑Yes Brio ❑NIA 7. Sufficient Volume: fes ❑No ❑NIA 8. Correct Containers Used: -Pace Containers Used: $ices Byes ❑No ❑No ❑NIA ❑NIA g. Containers Intact: .21 s ❑No ❑NIA 10. . Filtered volume received for Dissolved tests ❑Yes ❑No -ESNIA 11. Sample Labels match CDC: -Includes date/time/ID/Analysis Matrix: OY-es— ❑No LA)-7 ❑NIA 12. All containers needing preservation have been checked. All containers needing preservation are found to be in compliance with EPA recommendation. exceptions: VOA, coliform. TOC, obG, 1MI-DRO (water) _ U*e5 Yes ❑Yes ❑No ❑No ❑No ❑NIA ❑N1A 13. Initial when completed Samples checked for dechlo6nation:, ❑Yes [:)No — taNM 14. Headspace in VOA Vials (>6mm): ❑Yes ❑No L3W 15. Trip Blank Present: Trip Blank Custody Seals Present Pace Trip Blank Lot # (if purchased): NIA ❑Yes ❑Yes ❑No ❑No .CLwK 910A' 16. Client Notification/ Resolution: Field Data Required? Y I N I NIA Person Contacted: Date rime: Comments/ Resolution: Project Manager Review: Date:262 (d Note-. Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office ( Le out of hold, incorrect preservative, out of temp, incorrect containers) Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 March 06, 2009 Ms. Carol Hambridge Aware Environmental PO Box 2669 Matthews, NC 28106 RE: Project: Dixon Quick Coupling Pace Project No.: 9238936 Dear Ms. Hambridge: Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Enclosed are the analytical results for sample(s) received by the laboratory on February 27, 2009. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. Inorganic Wet Chemistry and Metals analyses were performed at our Pace Asheville laboratory and Organic testing was performed at our Pace Huntersville laboratory unless otherwise footnoted. All Microbiological analyses were performed at the laboratory where the samples were received. If you have any questions concerning this report, please feel free to contact me. Sincerely, Bonnie McKee bonnie.mckee@pacelabs.com Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. l' Page 1 of 9 n�, Pace Analytical Services, Inc. Pace Analytical Services, Inc. � alA 2225 Riverside Dr, 9800 ICnoeyAve. Suite 100 wwwpaJ " om Asheville, NC 28804 Huntersville, NC 28076 (828)254-7176 (704)875-9092 CERTIFICATIONS Project: Dixon Quids Coupling Pace Project No.: 9238936 Charlotte Certification IDs West Virginia Certification M 357 North Carolina Field Services Certification M 5342 Virginia Certification M 00213 North Carolina Drinking Water Certification M 37706 Tennessee Certification M 04010 New Jersey Certification M NC012 South Carolina Drinking Water Cert M 990060003 Louisiana/LELAP Certification M 04034 South Carolina Certification M 9900600D1 Kentucky UST Certification M 84 Pennsylvania Certification #: 68-00784 FloridaMELAP Certification M E87627 Connecticut Certification #: PH-0104 North Carolina Wastewater Certification #: 12 Asheville Certification IDs West Virginia Certification #: 356 Pennsylvania Certification #: 68-03578 Virginia Certification #: 00072 North Carolina Wastewater Certification M 40 Connecticut Certification M PH-0106 North Carolina Drinking Water Certification M 37712 Florida/NELAP Certification M E87648 North Carolina Bioassay Certification #: 9 Tennessee Certification #: 2980 New Jersey Certification M NC011 South Carolina Certification M 99030001 Massachusetts Certification #: M-NC030 South Carolina Bioassay Certification #: 99030002 LouisianalLELAP Certification #: 03095 Eden Certification IDs North Carolina Wastewater Certification M 633 North Carolina Drinking Water Certification M 37738 Virginia Drinking Water Certification M 00424 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 2 of 9 •ccc ceAnaly�i{cal a�ww.Amaedaha.o4m Project: Dixon Quids Coupling Pace Project No.. 9238936 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Pace Analytical Services, Inc. woo Kncey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 9238936001 Sample Location #2 EPA 1664A DNP 1 PASI-C EPA200.7 SHB 1 PASI-A EPA 9040 TEE 1 PASI-A SM 2540D SAJ 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services. Inc.. 4q �M CCp�O. o Page 3of9 a Pace Analytical Services, Inc. AWcal 2225 Riverside Dr. WWW. cem Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Dixon Quick Coupling Pace Project No.: 9238936 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 + (704)875-9092 Sample: Sample Location #2 Parameters Lab ID: 9238936001 Collected: 02/27/09 13:10 Received: Results Units Report Limit DF Prepared 02/27/09 14:40 Matrix: Water Analyzed CAS No. Quaff HEM, Oil and Grease Analytical Method: EPA 1664A Oil and Grease 16.7 mg/L 5.0 1 03/05/09 11:11 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 314 ug/L 5.0 1 03/03/09 10:15 03/03/09 21:24 7439-92-1 2540D Total Suspended Solids Analytical Method: SM 2540D Total Suspended Solids 108 mg/L 20.0 1 03/04/09 13:11 9040 pH Analytical Method: EPA 9040 pH 7.9 Std. Units 0.10 1 03/03/09 16:30 H6 Date: 03/06/2009 02:26 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. \4 Page 4 of 9 ceftVical Project: Dbcon Quick Coupling Pace Project No.: 9238936 QC Batch: WE T 7430 QC Batch Method: EPA 9040 Associated Lab Samptes: 9238936001 SAMPLE DUPLICATE: 244602 Parameter Units pH Std. Units Date: 03l0612009 02:26 PM Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: EPA 9040 Analysis Description: 9040 pH 9238856001 Dup Result Result RPD Qualifiers 9.0 9.0 0 H6 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services. Inc.. Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 9 wwwwolmlarm Project: Dixon Quick Coupling Pace Project No.: 9238936 QC Batch: WET17435 QC Batch Method: SM 2540D Associated Lab Samples: 9238936001 METHOD BLANK: 244608 Associated Lab Samples: 9238936001 Parameter Units Total Suspended Solids mg/L Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis Description: 2540D Total Suspended Solids Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 1.0 03/04/0913:11 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 ■ (704)875-9092 LABORATORY CONTROL SAMPLE: 244609 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mglL 250 224 90 BD-120 SAMPLE DUPLICATE: 244610 Parameter Total Suspended Solids Date: 03/06/2009 02:26 PM 9238936001 Units Result mglL 108 Dup Result 104 RPD Qualifiers 4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 6 of 9 eArWbal WWWPgaele &WM Project: Dixon Quick Coupling Pace Project No.: 9238936 QC Batch: GCSV/4885 QC Batch Method: EPA 1664A Associated Lab Samples: 9238936001 METHOD BLANK 245321 Associated Lab Samples: 9238936001 Parameter Units Oil and Grease mg1L Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: EPA 1664A Analysis Description: 1664 HEM, Oil and Grease Matrix. Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 03/05/0910:51 Pace Analytical Services, Inc. 9800 Kincey Ave, Suite 100 Huntersville, NC 28078 • (704)875-9092 LABORATORY CONTROL SAMPLE. 245322 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Oil and Grease mg/L 40 36.4 91 78-114 MATRIX SPIKE SAMPLE: 245323 9238494001 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Oil and Grease mg/L ND 40 31.2 78 78-114 Date: 03106/2009 02:26 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. ��r1• Qualifiers Page 7 of 9 ceAnalytical www,paeela8scorrt. Project: Dixon Quick Coupling Pace Project No.: 9238936 QC Batch: MPRP/3911 QC Batch Method: EPA 200.7 Associated Lab Samples: 9238936001 METHOD BLANK: 244011 Associated Lab Samples: 9238936001 Parameter Units ug/L Lead Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: EPA 200.7 Analysis Description: 200.7 MET Matrix: Water Blank Reporting Result Limit Analyzed ND 5.0 03/03/09 20:24 Qualifiers Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 • (704)875-9092 LABORATORY CONTROL SAMPLE: 244012 Spike LCS LCS % Rec Parameter Units Conc. Result %Rec Limits Qualifiers Lead ug/L 500 459 92 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 244013 244014 MS MSD 9238743001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Lead ug/L ND 500 500 444 432 89 86 70-130 3 SAMPLE DUPLICATE: 244015 Parameter Lead Date: 03/06/2009 02:26 PM 9238743002 Dup Units Result Result RPD Qualifiers ug1L ND ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 8 of 9 IrAeAnalytcal WWW..Aaaelab&C= QUALIFIERS Project: Dixon Quick Coupling Pace Project No.: 9238936 DEFINITIONS Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Pace Analytical Services, Inc. 9800 Knoey Ave. Suite 100 Huntersviile, NC 28078 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. U - Indicates the compound was analyzed for, but not detected. LABORATORIES PASI-A Pace Analytical Services -Asheville PAST-C Pace Analytical Services - Charlotte ANALYTE QUALIFIERS H6 Analysis initiated more than 15 minutes after sample collection. (704)875-9092 Date: 03/06/2009 02:26 PM REPORT OF LABORATORY ANALYSIS Page 9 of 9 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. is t -♦ . aceAnalyticala arrwssdlaas.tam CHAIN -OF -CUSTODY 1 Analytical Request Document The Chain -of -Custody Is a LEGAL DOCUMENT. All relevant fields must be completed accurately. Section A Section B Section C Pago: of Required Client information: Required Project Information: Involes Information: Compan Report To: �+ Attention: O 619 i , '_ f G� Address: Copy Ta: , �cr/' C 4 4 Company Name: W „ eV C ....� ... _ ... .... _ .. _ .. - REGiUIiATQRY;AfiENCY" •` Address: F NPDES r GROUNDWATER I- DRINKING WATER r UST i— RCRA (" OTHER Email To: Purchase Order No.: Paw Quote Rehrenw: G: Fax: Project Name Pa°° Praia '81tR LOCatlpn STA&. G Requeabd Due DatwrTAT: f:wfif4+ Project Number: Paw Pre61e Y .�' r l t Q =,, Requested Alialysis'Filtered.(YlNJ' ` • Section D Matrix Codes z' R"WredClient Information M&Mxl 1 CODE COLLECTED Pteseri/ (ws '>' Water water ow � Water wr Waste Water ww t P C BI��09rTE cotr�osl�tE Soillsolid SL y SAMPLE ID Wipe � < w IQ (AM 0.TBE Air AR Sample IDs MUST 13E UNIQUE Tissue TS IM Lu %GIL Other OT A zh Q. BATE TIME DATE TIME i x r ''�' .0 Pace Prooct NoJ Lab I.D. � 4T Lc+CrCl. mar-► D �. G "'/i8 4: za 3 4; k !' bnti fi 8 10 12 AbWTIONALCOMMeNTB RELINQUISNFDBYlAFFILIATION " fJAT!`}� TIME �+ACCEhil)BYIAFFILIATION ',•., DATE TIME' SAMPLQCONbRIONB Pi Va►7.�i Y ysOn Qr.a..,. /�� s q!t1�0 � ZO SAMPLER NAME AND SIGNATURE 0.Zew o $ b PRINT Name of SAMPLER. ORIGINAL 8 t SIGNATURE of SAMPLER: n BATE Signed l-� (MMIWD 'Important Note: By signing this form you are accapdng Pace's NET 30 day payment terms and egrgsing to into charges of 1.5% per month (or any Invol not geld within 30 days. IF F-ALL-Q-020rov.07, 15-May-2007 w_ _ r triple nditipi U oiiAdmp { FaceAnalytical Client Nam 1 Dyum [�'y C&,dnq, Project #_ if ❑ ❑ UPS ❑ USPS Client ❑ Courier: Fed Ex mmercial El Pace Cithar CustodySeal on Cooler/Box Present: Prot Di]e':Qate;rNlA T ❑ yes no Seals intact: � yes ❑ no r: I?rgtTlame^ /A, Packing Material: ❑ Bumble Wrap Bubble Bags ❑ None ❑Other Thermometer used T060 Type of lce�o Blue None Samples on ice. cooling process has begun TemperatureQ Biological Tissue is Frozen: Yes No NIA 9 Initials f er n examCooler =Ie'and ts: Temp should be above freezing to 6'C Comments: Chain of Custody Present: Yes ONO ❑NIA 1. Chain of Custody Filled Out: Ye ONO ❑N/A 2. Chain of Custody Relinquished: Ye ONO ❑NIA' 3. Sampler Name & Signature on COC: Ye ONO (]NIA 4. Samples Arrived within Hold Time: Yes ONO ❑NIA 5. Short Hold Time Analysis (<72hr): ❑Ye No ❑NIA 6. Rush Turn Around Time Requested: Yes ONO ❑NIA 7. Sufficient Volume: a ONO ❑NIA 8. Correct Containers Used: Yes�es ONO ❑NIA g. -Pace Containers Used: Idly; ❑No- ❑NIA Containers Intact: Yes ONO ❑wA 10. . Filtered volume received for Dissolved tests ❑Ye ONO NIA 11. Sample Labels match CDC: WrYes ONO ❑NIA 12. -includes date/time/ID/Analysis Matrix: W r4 All containers needing preservation have been checked. . es ❑No ©NIA 13. All containers needing preservation are found to be in Yes ❑No ❑NlA compliance with EPA recommendation. exceptions: VOA, coliform, TOC, O&G, WI-ORO (water) ❑Yes ❑No Initial when completed Samples checked for dechlorination: ❑Yes ONO Nl 14, Headspace in VOA Vials ( >6mm): Dyes ONO vlw 15. Trip Blank Present: ❑Yes. ❑No-, NIA . 6. Trip Blank Custody Seals Present EIYes'ONO IA Pace Trip Blank Lot #f (if purchased): NIA Client Notification! Resolution: Field Data Required? Y / N I NIA Person Contacted: DatelTime- Commentsl Resolution: Project Manager Review: Z A,1 }-F . _ . Date: _Q 2 — 21 Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office (i.e out of hold, incorrect preservative, out of temp, incorrect containers) • Pace Analytical Services, Inc. Pace Analytical Services, Inc. IrAeAnaocN 2225 Riverside Dr. 9800 Kincey Ave. Suite 100 Asheville, NC 28804 Huntersville, NC 28078 (828)254-7176 (704)B75-9092 August 05, 2009 Ms. Carol Hambridge Aware Environmental PO Box 2669 Matthews, NC 28106 RE: Project: DIXION QUICK COUPLING N290-10 Pace Project No.: 9249616 Dear Ms. Hambridge: Enclosed are the analytical results for sample(s) received by the laboratory on July 29, 2009. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. Inorganic Wet Chemistry and Metals analyses were performed at our Pace Asheville laboratory and Organic testing was performed at our Pace Huntersville laboratory unless otherwise footnoted. All Microbiological analyses were performed at the laboratory where the samples were received. If you have any questions conceming this report, please feel free to contact me. Sincerely, Kevin Herring for Bonnie McKee bonnie.mckee@pacelabs.com Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. �f`�1a Page 1 of 9 e Pace Analytical Services, Inc. Pace Analytical Services, Inc. 2225 Riverside Dr. 9800 IGncey Ave. Suite 100 wwiicpea�tabsoam Asheville, NC 28804 Huntersville, NC 2807E (828)254-7176 (704)875-9092 Project: DIXION QUICK COUPLING N2W10 Pace Project No.: 9249616 Charlotte Certification IDs Connecticut Certification #: PH-0104 Flodda/NELAP Certification #: E87627 West Virginia Certification #: 357 Virginia Certification #: 00213 Tennessee Certification #: 04010 South Carolina Drinking Water Cert. #. 990060003 South Carolina Certification M. 990060001 Asheville Certification lDs Connecticut Certification #: PH-0106 Virginia Certification #: 00072 Tennessee Certification #: 2980 South Carolina Certification #: 99030001 South Carolina Bioassay Certification M 99030002 Pennsylvania Certification #: 68-03578 West Virginia Certification #: 356 CERTIFICATIONS Pennsylvania Certification #: 68-00764 North Carolina Wastewater Certification #: 12 North Carolina Field Services Certification #: 5342 North Carolina Drinking Water Certification #: 37706 .New Jersey Certification #: NC012 Louisiana/LELAP Certification #: 04034 Kentucky UST Certification #: 84 North Carolina Drinking Water Certification * 37712 North Carolina Bioassay Certification M 9 New Jersey Certification #: NC011 Massachusetts Certification #: M-NC030 Louisiana/LELAP Certification #: 03095 Florida/NELAP Certification #: E67648 North Carolina Wastewater Certification #: 40 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services; Inc.. Page 2 of 9 0 ww�paoe(atiscam Project: DIXION QUICK COUPLING 14290-10 Pace Project No.: 9249616 Lab ID Sample ID 9249616001 SAMPLE LOCATION NO.2 Pace Analytical Services, Inc. 2225 Riverside Dr, Asheville, NC 28804 (B28)254-7176 SAMPLE ANALYTE COUNT Method Analysts EPA 1664A EAJ EPA 200.7 SHB EPA 9040 DMN SM 2540D TEE REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, _ without the written consent of Pace Analytical Services, Inc.. Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytes Reported Laboratory 1 PASI-C 1 PASI-A 1 PASI-A 1 PASI-A Page 3 of 9 ace AnaVical ` wwwP aelab&oam Project: DIXION QUICK COUPLING N290-10 Pace Project No.: 9249615 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 26804 (828)254-7176 ANALYTICAL RESULTS Pace Analytical Services, Inc. 9800 Kinsey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Sample: SAMPLE LOCATION NO.2 Parameters Laic ID: 9249616001 Collected: 07/28/09 16:45 Received: Results Units Report Limit DF Prepared 07/29/09 09:20 Matrix: Water Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664A Oil and Grease ND mg/L 5.0 1 08/04/09 12:30 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 101 ug/L 5.0 1 07/31/0913:20 08/0110914:44 7439-92-1 2540D Total Suspended Solids Analytical Method: SM 2540D Total Suspended Solids 4.2 mg l- 4.2 1 07/31/09 14:48 9040 pH Analytical Method: EPA 9040 pH 6.0 Std. Units 0.10 1 07/31/09 17:40 H6 Date: 08/05/2009 01:30 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 4 of 9 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: DIXION QUICK COUPLING N290-10 Pace Project No.: 9249616 QC Batch: GCSV/5942 Analysis Method: EPA 1664A QC Batch Method: EPA 1664A Analysis Description: 1664 HEM, Oil and Grease Associated Lab Samples: 9249616001 METHOD BLANK: 317468 Matrix: Water Associated Lab Samples: 9249616001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Oil and Grease mg/L ND 5.0 0810410912:22 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 LABORATORY CONTROL SAMPLE: 317469 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Oil and Grease mg/L 40 38.6 96 78-114 MATRIX SPIKE SAMPLE: 317470 9249137005 Spike MS MS % Rec Parameter Units Result Cone. Result % Rec Limits Qualifiers Oil and Grease mg/L ND 40 38.5 93 78-114 Date: 08/05/2009 01:30 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Ana"cal Services, Inc.. Page 5 of 9 aceArlalyfical wowpacalaba car+ Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)2547176 QUALITY CONTROL DATA Project: DIXION QUICK COUPLING N290-10 Pace Project No.: 9249616 QC Batch: MPRP/4844 Analysis Method: EPA 200.7 QC Batch Method: EPA 200.7 Analysis Description: 200.7 MET Associated Lab Samples: 9249616001 METHOD BLANK: 316214 Associated Lab Samples: 9249616001 Parameter Units Lead ug/L LABORATORY CONTROL SAMPLE. 316215 Parameter Units Lead ug/L Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 08/01/0914:07 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 500 521 104 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 316216 316217 MS MSD 9249713001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Lead ug/L ND 500 500 494 497 99 99 70-130 .6 SAMPLE DUPLICATE: 316218 Parameter Lead Date: OS/05/2009 01:30 PM 9249713002 Dup Units Result Resuft RPD Qualifiers ug1L ND ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Ina. 5`q y ♦CCO Of �n Page 6 of 9 I"A oAtWcal *wwPMXbb&0= Project: DIXION QUICK COUPLING N29D-10 Pace Project No.: 9249616 QC Batch: WET/9224 QC Batch Method: SM 2540D Associated Lab Samples: 9249616001 METHOD BLANK: 316320 Associated Lab Samples: 9249616001 Parameter Units Total Suspended Solids mg/L LABORATORY CONTROL SAMPLE: 316321- Parameter Units Total Suspended Solids mg/L SAMPLE DUPLICATE: 316322 Parameter Units Total Suspended Solids mg/L Date: 08/05/2009 01:30 PM Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis Description: 2540D Total Suspended Solids Pace Analytical Services, Inc. 9800 IGncey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Matrb(: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 07/31/0914:46 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 250 270 108 80-120 9249858001 Dup Resuft Result ND ND RPD Qualifiers REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 7 of 9 1ace/iqa1 s W&WFaGWabtaont Project: DIXION QUICK COUPLING N290-10 Pace Project No.: 9249616 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA QC Batch: WETl9228 Analysis Method: EPA 9040 QC Batch Method: EPA 9040 Analysis Description: 9040 pH Associated Lab Samples: 9249616001 SAMPLE DUPLICATE: 316327 9249500001 Dup Parameter Units Result Result RPD Qualifiers pH Std. Units 7.1 7.1 0 H6 Date: 08/05/2009 01.30 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. y [COy �r s Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Huntersville, NC 28078 , (704)875-9092 Page 8 of 9 wr'wAeoefaLsoan QUALIFIERS Project: DIXION QUICK COUPLING N290-10 Pace Project No_: 9249516 DEFINITIONS Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7178 Pace Analytical Services, Inc. 9800 KnceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable_ Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. U - Indicates the compound was analyzed for, but not detected. LABORATORIES PASI-A Pace Analytical Services -Asheville PAST-C Pace Analytical Services - Charlotte ANALYTE QUALIFIERS HS Analysis initiated more than 15 minutes after sample collection. Date. 08/05/2009 01:30 PM REPORT OF LABORATORY ANALYSIS Page 9 of 9 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. :f ,DaceArralyi a is 1' wws.aacatsha.esm CHAIN -OF -CUSTODY 1 Analytical Request Document The Chain -of -Custody Is a LEGAL DOCUMENT. All relevant fields must be completed accurately. Section A Section B Section C Page. of Required Client Information: Required Project Informatlon: Invoice Informatfon: ^ ^ ^ Campan Rew" Tw - Attention: b L b , eR is r Address; Q Copy To: Compan me: REGULATORY.AGENCY y v.Ile a� Address. r- NODES 1' GROUND WATER r DRINKING WATER F^ UST j'" RCRA (' OTHER Email To: Purchase Order No.: Pace quote RNennce: P ne: fax: Project N r cr v Il+ro Ped Pro.Igo anagr: Site Location STATE: _yG Regwatsd ue AT: ProjeetNuml�er. f aoaProNee rff2 ,- ,Ty.Req��ttited Atieljfsls Filleted (YM} , Section D Matrix Codes RequlmdClientlnfamatlon pE $ COLLECTED Preservatives 'st Drinking water DW o Water wT Waste Water WW r5 CotrrosTE COMPOenE END00M _ Product P aTAAT Soil/Sodd SL oilOL L j SAMPLE ID wP p `� v m (AZ.0>3r, i Air AR o 2.515 Semple IDs MUST BE UNIQUE Tissue TS U y Other OT X = 0 w S O O ;C 1 Y = DATE TIME DATE TIME Pace Project No,J Lab I.D. 1 S 1 o,a! f5 xy- 14LW=S 2 a 4 6 8 7 8 g is 11 12 ADDITIONAL COMMENTS RELINQUISHED BY 1 AFFILIATION •' DATE ME' + w ACCEPTEp SY! AFf141AT1ON DATE TIME SAMPLE CONDITIONS Tarr '' r- >iFDt� t Cove usr� ORIGINAL SAMPLER NAME AND SIGNATURE PRINT Name of SAMPLER: Q to +. rfCr E + gZ r a+ SIGNATURE of SAMPLER: DATE Signed (MM/Do y 9mporlant Note: 6y slgninp this form you are accepting PwA's NET 30 day payment terms and awaeinq to late Chases nr 1.5-6 ee th tnr env lnvnira not neln wnhin M7 rave F-ALL-0-020rev.07. f 5-May-2007 IN ill M, - .. • aceAralytical Client Name• an Project # 1 5(!0$ Courier: ❑ Fed Ex ❑ UPS ❑ USPS Client eno mmerciat ❑ Pace Other CustodySeal an Cooler/Box Present: es Seats intact: Pro 4Q►te3Date 1`skff[�❑ Y❑ Yes �o =� 4- Packing Material: ❑ Bubble Wrap ❑Bubble Sags None 00ther Thermometer Used T060 Type of Ice:A07), et Blue None Samples on ice. caofrnR process has begun Cooler Temperature , Temp should be above freezing to 6'C V Biological -Tissue is Frozen: Yes No NIA Comments - Date and initia o erso i ing contents: Chain of Custody Present: dy7 ❑No ❑NIA 11. Chain- of Custody Filled Out: dyv ❑No ❑NIA 2. Chain'of Custody Relinquished: As, 0No ©NIA 3, Sampler Name & Signature on COC: Ye ❑No ❑NIA 4. Samples Arrived within Hold Time: Yes ONO ❑NIA 5. Short Hold Time Analysis (<72hr): OYej, No ❑NIA $, Rush Turn Around Time Requested: Yes ❑No ❑NIA 7_ Sufficient Volume: zlyoe ONO ❑NIA 8. Correct Containers used:-. -Pace Containers Used: Ye IQye ❑No ❑No. ❑NIA ❑NIA g• Containers Intact: 0111 ZYes ❑No ❑NIA 10, . Filtered volume received for Dissolved tests ❑Yes ON. NIA 11, Sample Labels match COC: -Includes date/timeAD/Analysis Matrix: ❑Yes No ❑NIA 12_ �pfeit/e 0. /�wrr� S rA 8� S All containers needing preservation have been checked.. All containers needing preservation are found to be in compliance with EPA recommeridation. exceptions: VOA, coliform, TOC, O&G, VA-DRO (water) Yes /Ye. Oyes. ❑No ❑No ONO ❑NIA ❑NIA 13. � Des � Initial when completed W L'., `, wan n`tGc iJ`*`� (� `fi' CcAfin Q Samples checked for dechlorination: Oyes ONO NIA 14. Headspace in VOA Vials ( >6mm): ❑Yes ONO Owl 15. Trip Blank Present: Trip Blank Custody Seals Present Pace Trip Blank Lot # (it purchased): NIA ❑Yes ❑Yes ❑No • ONO dN NIA 16. Client Notification/ Resolution: Field Data Required? Y / N / NIA Person Contacted. Date/Time: Comments/ Resolution: Project Manager Review: &Y • , Date: GY (P Q Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office (i.e out of hold, incorrect preservative, out of ternp, incorrect containers) #8572: Metals Page 1 of 2 BEST PRACTICAL TM X Results e Ticket 8572 created in queue 'Rush Requests' X Ticket metadata X The Basics Id: 8572 Status: new Left: 0 min Priority: 99/99 Queue, Rush Requests X Custom Fields Tests: a Lead Number of Samples: a 1 Sample Matrix: a Water Client: a Dixon Quick Coupling Project Name/Reference: ' Dixon Quick Coupling Rush Surcharge Multiplier: o (no value) Requested TAT: a 2 day Date Required By: o 09/26/09 Total Revenue of Rush ' (no value) Project: Expected Date of Arrival: a 09/24/09 Comments: a (no value) SVOA Approval: a (no value) SVOA Rejection Reason: a (no value) SVOA Renegotiated TAT: a (no value) VOA Approval: a (no value) VOA Rejection Reason: a (no value) VOA Renegotiated TAT: a (no value) Metals Approval: . (no value) Metals Rejection Reason: a (no value) Metals Renegotiated TAT: a (no value) Wet Chem Approval: o (no value) Wet Chem Rejection o (no value) Reason: Wet Chem Renegotiated o (no value) TAT: Final Outcome: a (no value) Lost Reason: a (no value) Proj #: a (no value) Did Lab meet agreed TAT?: o (no value) Comments for missed TAT o (no value) date: X People Owner: bhelton <Brandon.Helton@pacelabs.com> Preferences I L.ogout Logged in as bheiton X Dates Created: Mon Aug 24 13:47:34 2009 Starts: Not set Started: Not set Con ct Not set Due: Tue Aug 2S 17:45:58 2009 Closed: Not set Updated: Mon Aug 24 13:47:36 2009 by bheiton X Links Depends on: Depended on by: Parents: Children: Refers to: Referred to by: http://92]abtrack/7icket/Create.html 8/24/2009 ImARalyieaf WWWWcel ftmn August 31, 2009 Terry Carter Dixon Quick Coupling 332 Atando Ave Charlotte, NC 28206 RE: Project: DIXON QUICK COUPLING Pace Project No.: 9251568 Dear Terry Carter. Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 PaceAna"cal Services, Inc. 9800 IGncey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Enclosed are the analytical results for sample(s) received by the laboratory on August 24, 2009. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. Inorganic Wet Chemistry and Metals analyses were performed at our Pace Asheville laboratory and Organic testing was performed at our Pace Huntersville laboratory unless otherwise footnoted. All Microbiological analyses were performed at the laboratory where the samples were received. If you have any questions concerning this report, please feel free to contact me. Sincerely, Brandon Helton brandon.heiton@pacelabs.com Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Lp�Q Page 1 of 8 IeAnalyfjcal a �r+r:pa6e(aGsoom. Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersviiie, NC 28078 Project: DIXON QUICK COUPLING Pace Project No.: 9251568 Asheville Certification iDs Connecticut Certification #: PH-0106 Florida/NELAP Certification #: E87648 Louisiana/LELAP Certification #: 03095 Massachusetts Certification #•. M-NC030 New Jersey Certification #: NC011 North Carolina Bioassay Certification #: 9 West Virginia Certification #: 356 (828)254-7176 CERTIFICATIONS North Carolina Wastewater Certification #: 40 Pennsylvania Certification #: 68-03578 South Carolina Bioassay Certification #: 99030002 South Carolina Certification M. 99030001 Tennessee Certification #: 2980 Virginia Certification #: 00072 North Carolina Drinking Water Certification #: 37712 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. !L a (704)875-9092 Page 2 of 8 ceAnaly ical e ww*paeef min Project: DIXON QUICK COUPLING Pace Project No.: 9251568 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 9251568001 TRUCK SAMPLE EPA 200.7 SHB 1 PASI-A 9261568002 OUTFALL EPA 200.7 SHB 1 PASI A REPORT OF LABORATORY ANALYSES This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 3 of 8 �Ice Analyiical W*W.Pac@absxaxen Project: DIXON QUICK COUPLING Pace Project No.: 9251568 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Pace Anatytical Services, Inc. 9800 KinceyAve, Suite 100 Huntersville, NC 28078 (704)875-9092 Sample. TRUCK SAMPLE Lab ID: 9251568001 Coffected: 08/24/09 10:30 Received: 08/24/09 11:35 Matra: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qua] 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead ND ug1L 5.0 1 08/25/09 11:50 08/26/09 00:23 7439-92-1 Sample: OUTFALL Lab ID: 9261668002 Collected: 08/24/09 10:30 Received: 08/24/09 11:35 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 2007 Lead 41.0 ug/L 5.0 1 08/28/09 10:50 08/29/09 06:24 7439-92-1 Date: 08/31/2009 05:17 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 4 of 8 IeAnalytical� pae &Ws.c= Project: DIXON QUICK COUPLING Pace Project No.: 9251568 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 QC Batch: MPRP/4982 Analysis Method: EPA 200.7 QC Batch Method: EPA 200.7 Analysis Description. 200.7 MET Associated Lab Samples: 9251568002 METHOD BLANK 328856 Matrix: Water Associated Lab Samples: 9251568002 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Lead ug/L ND 5.0 08/29/09 06:06 LABORATORY CONTROL SAMPLE: 328857 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Lead ug/L 500 467 93 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 328858 328859 MS MSD 9251568002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qua] Lead ug/L 41.0 500 500 479 480 88 88 70-130 0 SAMPLE DUPLICATE: 328860 Parameter Lead Date: 08/31/2009 05:17 PM 9251860001 Dup Units Result Result ug/L ND ND RPD Qualifiers REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 5 of 8 f�ce,4nalytical. Project: DIXON QUICK COUPLING Pace Project No.: 9251568 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville. NC 28804 (828)254-7178 QUALITY CONTROL DATA f Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QC Batch: MPRP/4960 Analysis Method: EPA 200.7 QC Batch Method: EPA 200.7 Analysis Description: 200.7 MET Associated Lab Samples: 9251568001 METHOD BLANK 326710 Matrix: Water Associated Lab Samples: 9251568001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Lead ug/L ND 5.0 08/26/09 00:14 LABORATORY CONTROL SAMPLE: 326711 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Lead ug/L 500 487 97 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 326712 326713 MS MSD 9251568001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Lead ug/L ND 500 500 476 468 95 94 70-130 2 SAMPLE DUPLICATE: 326714 Parameter Lead Date: 08/31/2009 05:17 PM 9251574001 Dup Units Result Result ug/L 145 141 RPD Qualifiers 3 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytcai Services, Inc.. o , Page 6 of 8 aceAnaVieal. rrWPVc0bDxcorrl QUALIFIERS Project: DIXON QUICK COUPLING Pace Project No.: 9251558 DEFINITIONS Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254 7176 Pace Analytical Services, Inc. 980D KinceyAve. Suite 100 Huntersville, NC 28078 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 listed anatyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - relative Percent Difference NC - Not Calculable. Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited anatytes. U - Indicates the compound was analyzed for, but not detected. LABORATORIES PASI-A Pace Analytical Services -Asheville (704)875.9092 Date: 08/31/2009 05:17 PM REPORT OF LABORATORY ANALYSIS Page 7 of 8 This report shall not be reproduced, except in hull, without the written consent of Pace Analytical Services, Inc.. /�k'WkWcal* f wwrcpecerabs.00nr Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: DIXON QUICK COUPLING Pace Project No.: 9251568 Pace Analytical Services, Inc. 98001GnceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 9251568001 TRUCK SAMPLE EPA 200.7 MPRP/4960 EPA 200.7 ICP/4604 9251568002 OUTFALL EPA 2001 MPRP/4982 EPA 200.7 ICP/4620 Date: 08/31/2009 05.17 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 8 of 8 ,)!;' e.l.he enee CHAIN -OF -CUSTODY 1 Analytical Request Document The Chain-O-Custody is a LEGA- L DOCUMENT. Ail relevant fields must be completed accurately. Section A Section 8 Section C Page: of Required Client Information: Required Project Information: Involte Information: Comw u C . Report To: err ! f Attention: Vresji 1326908 Add ii � � Au Copy To: Campany Name:, R6l31JIATORY. AGENCY 1041 s I. -AG $ l0 Address: r NPDES r GROUNDWATER r DRINKING WATER j UST r RCRA r OTHER it To: Purchase Order No.: Pans Quote P na: fax: O Project e: 1 bV% 091r,ic Cb u ' fn Pete "ad Ma- 8RD Location ; SrATE. RequestedProJadNumber: PaeProfile#: Requested Analysls Flltered (Y/N) Section D Matrix Codes o' z; Requ1ndClfenelnfarma8on �JATnuc r CODE: COLLECTED Preservatives P; Drinking Water DW Water WT zi 0 Waste Water WW Product P COMPOSITE START COMPOSITE ENMRAD Soil/Solid SL. Oilwipe iiiW333 SAMPLE ID WP SA Z, 0 9! r) Air AR a y a 2�3��'� Sample IDs MUST BE UNIQUE Tissue TS O a Other OT10 Q 8 r1 0C 9 O O p� � x Z1 DATE TIME DATE TIME 1 1 1 1 Paco Project NoJ Las I.D. 1 1&xmo Ia. I too. as <g„ i 2 is ;k, Q V,as 9 5'< �F, rid 7 .1 { 9 yc 10A 11 F 12 ADDITIONAL COMMENTS REUNOUISMEDSYIAFFILIATION' DATE TIME - ACCE ll!YIAFMLIATION• DATE TIME SAMPLE CONDITIONS 5 is, ORIGINAL SAMPLER NAME AND SIGNATURE a E �I PRINT Name of SAMPLER: *-,-r ( r SIGNATURE of SAMPLER: DATE Signed IT `— MWDD : 'ImWnani Note: By signina this form you am aeeeoiina Pace's NET 30 day oavmant efara end arv-nine In WA rmnn— nt I FY — —th ft..nv Inv rw —W -thin Ym n.— F_Ai 14n-n7nnmv 07 T R-Mav-9nn7 % aceAr�alytica!- n Client Name: y--- Project # ` :;� 6 �LP(P Courier: ❑ fled Ex ❑ UPS ❑ USPS jent ❑ Commercial ❑ Pace Other OptionI==3A CustodySeal on Cooler/Box Present: es no Seals intact: Prof Dte Dafe NIA `- ❑Y ❑yes Prod Nart7e _ Ntf .._ ,f�_ Packing Material: ❑ Bubble Wrap []Bubble Bags �e ❑Other Thermometer Used T060 Type of lce: et _)�lue None Samples on ice, cooling process has begun Cooler Temperature. Temp should be above freezing to 6'C #-�' Biological E Is Frozen: Yes No NIA Comments: gate and ]nit is of person examining contents: �s Chain of Custody Present: --f1Yes ONo ❑NIA 1. 12. Chain of Custody Filled Out: _,L;i'res ONo ❑NIA Chain of Custody Relinquished: es ONO ❑NIA 3. Sampler Name & Signature on COC: J.93res ONO ❑NIA 4. Samples Arrived within Hold Time: ONo ❑NIA 5. Short Hold Time Analysis (<72hr): ❑Yes PW' ONIA 6. Rush Turn Around Time Requested: s ONo ❑NIA 7. Sufficient Volume: es ONO ❑NIA $. Correct Containers Used: -Pace Containers Used: s es ONO ONo. ❑NIA ❑NIA 9. Containers Intact: _ ONO ❑NIA 10. . Filtered volume received for Dissolved tests ❑Yes ONO. 11. Sample Labels matchCOC: -Includes date/time/ID/Analysis Matrix: Oyes P<_❑NIA 12. ,� ( a(}s, . r�' T��1^S�rNr,cc a kw. All containers needing preservation have been checked. All containers needing preservation are found to be in compliance with ERA recommersdation. exceptions: VOA, mlitorm, TOC, O&G. VA-DRO (water) ,,QY-es ❑Yes ONO ONO ONO ❑NIA ❑NIA 13. Initial when.completed Samples checked for dechlorination:, ❑Yes ONO 14. Headspace in VOA Vials (>6mm): ❑Yes ONO �A 15. Trip Blank Present: Trip Blank Custody Seals Present Pace Trip Blank Lot # (if purchased): NIA ❑Yes ❑Yes ❑No -tfN/A ONO A 16. Client Notification/ Resolution: Field Data Required? Y I N J NIA Person Contacted: Datefrime: Comments/ Resolution: Project Manager Review: C(�(,t� Date: 2 (� Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office (i.e out of hold, incorrect preservative, out of temp, incorrect containers) ceAnalytical' r wwvpacefabxcam. 1 September 25, 2009 Terry Carter Dixon Quick Coupling 332 Atando Ave Charlotte, NC 28206 RE: Project: DIXON QUICK COUPLING 9/23 Pace Project No.: 9253667 Pace Analytical Services, Inc. 2225 Riverside Dr, Asheville, NC 28804 (828)254-7176 Pace Analytical Services, Inc. 9800 ICincey Ave. Suite 100 Huntersville. NC 28078 Dear Terry Carter: Enclosed are the analytical results for sample(s) received by the laboratory on September 23, 2009. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. Inorganic Wet Chemistry and Metals analyses were performed at our Pace Asheville laboratory and Organic testing was performed at our Pace Huntersville laboratory unless otherwise footnoted. All Microbiological analyses were performed at the laboratory where the samples were received. If you have any questions concerning this report, please feel free to contact me. Sincerely, Brandon Helton brandon.heiton@pacelabs.com Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the mitten consent of Pace Analytical Services, Inc.. goo `i'.'_ (704)875-9092 Page 9 of 7 V[iI'7!!R�%Ql wwwpeoefafraoom Project_ DIXON QUICK COUPLING 9/23 Pace Project No.: 9253667 Asheville Certification IDs West Virginia Certification #: 356 Virginia Certification*: 00072 Tennessee Certification #: 2980 South Carolina Certification * 99030001 South Carolina Bioassay Certification #: 99030002 Pennsylvania Certification #: 68-03578 Connecticut Certification #: PH-0106 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 CERTIFICATIONS North Carolina Drinking Water Certification #: 37712 North Carolina Bioassay Certification #: 9 New .Jersey Certification #: NC011 Massachusetts Certification M. M-NC030 Louisiana/LELAP Certification #: 03095 Florida/NELAP Certification #: E87648 North Carolina Wastewater Certification #: 40 REPORT OF LABORATORY ANALYSIS This report shall nol be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. w Pace Analytical Services, Inc. 9800 Kincey Ave, Suite 100 Huntersville, NC 28078 (704)875.9092 Page 2 of 7 ��aceAna' Project: DIXON QUICK COUPLING 9/23 Pace Project No.: 9253667 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT I Pace Analytical Services, Inc. 9800 Kinoey Ave. Suite 100 Hurrtersville, NC 28078 , (704)875-9092 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 9253667001 SAMPLE 1 WATER TRUCK EPA 200.7 SHB 1 PASI-A 9253667002 SAMPLE 2 LOCATION #2 EPA200.7 SHB 1 PASI A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. V4 •`�.,�1i Page 3 of 7 1J S "OeAnalyfical* www.p�apei�h�aoar Project: DIXON QUICK COUPLING 9/23 Pace Project No.: 9253667 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7178 ANALYTICAL RESULTS Pace Analytical Services, Inc. 98001C1nceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Sample: SAMPLE 1 WATER TRUCK Lab ID: 9253667001 Collected: 09/23/09 10:35 Received: 09/23/09 11:35 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead ND ug/L 5.0 1 09/24/09 12,00 09/24/09 20:49 7439-92-1 Sample: SAMPLE 2 LOCATION #2 Lab ID: 9253667002 Collected: 09/23/09 10:35 Received: 09/23/09 11:35 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 145 ug/L 5.0 1 09/24/09 12:00 09/24/09 21:02 7439-92-1 Date: 09/25/2009 04:05 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. O « tp n a �\-J z Page 4 of 7 1���IceAnaVicale J tiw wPscat"conl Project: DIXON QUICK COUPLING 9/23 Pace Project No.: 9253667 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA QC Batch: MPRP/5114 Analysis Method: EPA 200.7 QC Batch Method: EPA 200.7 Analysis Description: 200.7 MET Associated Lab Samples: 9253667001, 9253667002 METHOD BLANK: 340854 Matra: Water Associated Lab Samples: 9253667001, 9253667002 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Lead ug/L ND 5.0 09/24/09 20:31 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 LABORATORY CONTROL SAMPLE: 340855 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Lead ug/L 500 504 101 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 340856 340857 MS MSD 9253667001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Lead ug/L ND 500 500 469 475 94 95 70-130 '1 SAMPLE DUPLICATE: 340858 Parameter Lead Date: 09/25/2009 04:05 PM Units ug/L 9253667002 Dup Result Result 145 144 RPD Qualifiers 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. 0 Cps Page 5 of 7 ,�Ir,l W*WPaCebb&=n QUALIFIERS Project: DVON QUICK COUPLING 9/23 Pace Project No.: 9253667 DEFINITIONS Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersviffe, NC 28D78 • (704)875-9092 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot; or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrac Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. U - Indicates the compound was analyzed for, but not detected. LABORATORIES PASI-A Pace Analytical Services -Asheville Date: 09/25R0D9 04:05 PM REPORT OF LABORATORY ANALYSIS Page 6 of 7 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. «o. Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 288D4 (828)254-7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: DIXON QUICK COUPLING 9123 Pace Project No.: 9253667 PaceAna"cal Services, Inc. 98DO Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 9253667001 SAMPLE 1 WATER TRUCK EPA 200.7 MPRP/5114 EPA 200.7 ICP14746 9253667002 SAMPLE 2 LOCATION #2 EPA 200.7 MPRP/5114 EPA 200.7 ICP14746 Date: 09/25/2009 04:05 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. .reo at` Page 7 of 7 . aceAnal1�ical' y` ..w. n■eN■h. rtnm CHAIN -OF -CUSTODY I Analytical Request Document The Chain -of -Custody Is a LEGAL DOCUMENT. All relevant fields must be completed accurately. Section A Section B section C Page: of Required Client Information: Required Project Information, Invoice Informatlon: Compare RapoA To: Attention: ^ ^ ^ O s b y /� _ { t< t Lam+ C Address 3 Copy To: Company Name: REGULATOR_ Y AGENCY bra' r NPDSS r GROUND WATER r- DRINKING WATER r UST j— RCRA r OTHER Email T Purchase Cyder No.: Para Quote eI Reference: Phone: Felt: •[CIS► Project Nam t 11t I Pace Pmjeq Slte Location .-3 4 • tC3�1 a+ C as I n Manager. . ct Roque Project Number. Pen Profile M: stelfA : 54 STATE: ;.•.,.. Regilested:AnalysisFiltared {YINj Ssetion D Matrix Codes FM RequlradCgent lalormation MATRIX r CODE e COLLECTED Preservatives S~'t Ddrlklydg Water DW water wT u O Q r dte water yyvlf Product c010111 E srAar co mpoallE fNOVCtRMB SollfSold SL ► SAMPLE ID OL c7 Wipe (A-Z, 0-9I ,-) Air AR Semple ID; MUST BE UNIQUE Tissue TS U uJ a Other O7 2 d S ' DATE TIME DATE TIME u O Pace Project No./ Lab I.D. 1 r frF-, 2 f of A1�1 3 5. 4 !S :sr B T F�; � e e 1g if 12 ADDITIONAL COMMENTS RELINCUISHEb BY I AFFILIATION DATE '; TIME ACCEPTED BY.I' AFFILIATION' DATE TIME SAMPLE CONDITIONS to l a% IS! P't UN r Pt� SAMPLERNAMEAND SIGNATURE ORIGINAL PRINT Name of SAMPLER: it r C.9%tiee a X DATE Signed SIGNATURE of SAMPLER: m F, U - MM1DD q *Important Nate: By signing this dam you am aaoepwq Pace's NET 30 day payment terns and agreeing to late charges of 1.5% per month danv impLas real raid wAhln an n.- AM_ And_iPQM. -eceip -FaceAnalyfica!' Client Name: _ t �L�- _ Project # 92 55 Sr7 Courier: ❑ Fed Ex ❑ UPS ❑ USP , Client ❑ Commercial Custody Seal on Cooler/Box Present: ❑ yes no Seat; Packing Material: ❑ Bubble Wrap []Bubble Bags None Thermometer Used T060 iCrtYV1�� �,X4pe of lce:(l I_7 Pace Other Q.Otidiiap% w Pro Due Date N/Ar intact: yes �o-r rr� a[ile�/e3"s ❑ ❑Othef � �_:. Blue n Samples on ice, cooling process has begun Biological 1— Cooler Temperature �" 4 i g-cat Tissue is Frozen: Yes No NIA Temp should be above freezing to 61C Comments: Date and lnit- f of persgrs exami contents: Chain of Custody Present: s ONO ❑NIA 1. Chain of Custody Filled Out: oYrs ❑No ❑NIA 2• Chain of Custody Relinquished: Yes ❑-No ❑NIA 3. Sampler Name & Signature on COC: es ONO ❑NIA 4. Samples Arrived within Hold Time: es ❑flo ❑NIA 5. Short Hold Time Analysis (<72hr): Dyes i7o ❑NIA 6• Rush Turn Around Time Requested: es ❑tJo :ONIA 7_ Sufficient Volume: Yes Oft ❑NIA 8. Correct -Containers Used: -Pace Containers Used: Yes es ❑lira ❑N.- ON/A ❑NfA 9. - Containers Intact: es ONO '❑NIA 10. . Filtered volume received for Dissolved tests ❑Yes ONO 11. Sample Labels match COC: -includes date/lime/ID/Analysis Matrix: Dyes o __[]N/A 12, .�� S S � rJ S�mnk r� 1_ C�.t �° I t� L1 95 7 All containers needing preservation have been checked. All containers needing preservation are found to be in with EPA recommendation. exceptions: VOA, coGrorm. TOC. O&G. WI-DRO (water) es ❑No es No Dyes ONO 't 1� 1N1A ❑N1A �'"' Z 1 J t 1[ O 13y.- L ya {. _ S I r C'r/?- �u 1�-�-.�}[ 1 t>O�compliance 111^ Initial when comp* h� YJ� ; I L r n , 1A i Samples checked for dechlorination.- ❑Yes ONO NIA 14. Headspace in VOA Vials (>6mm): ❑Yes ONO 15. Trip Blank Present: Trip Blank Custody Seals Present Pace Trip Blank Lot # (if purchased): NIA Dyes ❑Yes ONO . ONO ��A t�N/A IA 16. Client Notification/ Resolution: Field Data Required? Y / N / N/A Person Contacted: Comments/ Resolution: Date/Time: Project Manager Review:. Date: /d ­2Z —Q 15 Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office (Le out of hold, incorrect preservative, out of temp, incorrect containers) N ceAnaVical WWW48iale MWM October 26, 2009 Mr. Terry Carter Dixon Quick Coupling 332 Atando Ave Charlotte, NC 28206 RE: Project: Dixon Quick Coupling 10/22 Pace Project No.: 9255879 Dear Mr. Carter: Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Enclosed are the analytical results for sample(s) received by the laboratory on October 22, 2009. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. Inorganic Wet Chemistry and Metals analyses were performed at our Pace Asheville laboratory and Organic testing was performed at our Pace Huntersville laboratory unless otherwise footnoted. All Microbiological analyses were performed at the laboratory where the samples were received. If you have any questions concerning this report, please feel free to contact me. Sincerely, Brandon Helton brandon.heiton@pacelabs.com Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This reporl shall not be reproduced, except in hip, without the written consent of Pace Analytical Services, Inc.. p �� ♦GCp�\y �n Page 1 of 7 aceAnalyticai" WWWPW&Wm0om Project: Dixon Quick Coupling 10122 Pace Project No.: 9255879 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 CERTIFICATIONS Asheville Certification Ids West Virginia Certification #: 356 North Carolina Drinking Water Certification #: 37712 Virginia Certification M 00072 North Carolina Bioassay Certification M 9 Tennessee Certification #: 2980 New Jersey Certification #: NC011 South Carolina Certification * 99030001 Massachusetts Certification #. M-NCO30 South Carolina Bioassay Certification M 99030002 Louisiana/LEIAP Certification #: 03095 Pennsylvania Certification #: 68-03578 Florida/NELAP Certification #: E87648 Connecticut Certification #: PH-0106 North Carolina Wastewater Certification M 40 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in Tull, without the written consent of Pace Analytical Services, Inc.. . ,'.♦.C. n yo. Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 7 IeAnalyticaf ww*tpatl0ab&0= Project: Dixon Quick Coupling 10122 Pace Project No.: 9255879 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254.7175 SAMPLE ANALYTE COUNT Pace Analytical Services, Inc. 9800 ICincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 9255879001 SAMPLE 1 WATER TRUCK EPA 200.7 JMW 1 PAS! A 9255879002 SAMPLE 2 LOCATION 2 EPA200.7 JMW 1 PASIA REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, exoept in full, without the written consent of Pace Analytical Services, Inc.. Page 3 of 7 eAtWcaI wwrcpaoawmew Project: Dixon Quids Coupling 10/22 Pace Project No.: 9255879 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Pace Analytical Services, Inc. 9800 Kinsey Ave. Suite 1 OD Huntersville, NC 28078 (704)875-9092 Sample: SAMPLE 1 WATER TRUCK Lab ID: 92SN79001 Collected: 10/22/09 14.35 Received: 10/22/09 15:24 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 200.7 NET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead ND ug/i_ 5.0 1 10/23/09 14:50 10/26/09 14:25 7439-92-1 Sample: SAMPLE 2 LOCATION 2 Lab ID: 9256879002 Collected: 10/22/09 14:30 Received: 1012210915:24 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qua[ 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 56.1 ug1L 5.0 1 10/2310914:50 10126/0914:29 7439-92-1 Date: 10/26/2009 03:33 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. LM •CCp� Page 4 of 7 IcleAnalydcal W&Wpaml0moem Project: Dixon Quick Coupling 10/22 Pace Project No-: 9255879 QC Batch: MPRP/5262 QC Batch Method: EPA 200.7 Associated Lab Samples: 9255879001, 9255879002 METHOD BLANK: 355394 Associated Lab Samples: 9255879001, 9255879002 Parameter Units Lead ug/L Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: EPA 200.7 Analysis Description: 200.7 MET Matrix: Water Blank Reporting Result Limit Analyzed ND 5.0 10126/0913:47 Qualifiers Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 LABORATORY CONTROL SAMPLE: 355395 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Lead ug/L 500 498 100 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 355396 355397 MS MSD 9255481012 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc- Conc. Result Result % Rec % Rec Limits RPD Qual Lead ug/L ND 500 506 487 493 97 98 70-130 1 SAMPLE DUPLICATE: 355398 Parameter Lead Date: 10/26/2009 03:33 PM 9255481013 Dup Units Result Result ug/L ND ND RPD Qualifiers REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 5 of 7 �aveAnWical" WWWP803WM ow QUALIFIERS Project: Damn Quids Coupling 10r22 Pace Project No.: 9255879 DEFINITIONS Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes toAzobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. U - Indicates the compound was analyzed for, but not detected. LABORATORIES PASI-A Pace Analytical Services -Asheville (704)875-9092 Date: 10/26r2009 03:33 PM REPORT OF LABORATORY ANALYSIS Page 6 of 7 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. s Pace Analytical Services, Inc. n r nayi 2225 Riverside Dr. ,m' om1 Asheville, NC 28804 f (828)254-7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Dixon Quick Coupling 10/22 Pace Project No.: 9255879 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 9255879001 SAMPLE 1 WATER TRUCK EPA 200.7 MPRPI5262 EPA 200.7 ICP14883 9255879002 SAMPLE 2 LOCATION 2 EPA 200.7 MPRPI5262 EPA 200.7 ICP/4883 Date: 10/26/2009 03:33 PM . REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. .moo CLI Page 7 of 7 ' PaceAnall��+}ical e m.wn-IeE�.eem CHAIN -OF -CUSTODY 1 Analytical Request Document The Choin-0f-Custody is a LEGAL DOCUMENT. All relevant fields must be completed accurately. Section A . Section 8 Section C Pape: of Required Client Information: Required Project Information: Invoice Informatlorr. Compan • RaW To: Attention: 1358595 d Address;Copy To: Company Name REf3ULATORYACiENCY re Address: F— NPDES r GROUNDWATER r DRINKING WATER r UST ( RCRA r OTHER Email T purchase Order No.: Pace Quote Reference: R Phone; uw. "ad Nam ' Pea pmea Site Location ` -.RC aJ I Manager. SYA TE: Requested Due T: ProJad Number. Psu Promo e: C! 3 ' 19equeatea ane.jysis Fatered (YIN) Section D Matrix Codes .� 2 ' Required ClientInformaaon L 8 COLLECTED Preservatives :;:.t Dnnklna Water DW Water WT Waste Water WW Product P V COMPOGITR START COMPpaITa ENDKaaaS SoillSolid SL SAMPLE ID DII OL WF 0-9 _ W x (A-Z. Aires R Sample IDS MUST BE UNIQUE Tissue TS p w IL 1 ttt...JJJIII Other OTg U pp + FF Q dz, U m� 'W TIME = D=LK Q O av�1 N`-- Pace Pro d. DATE TIME DATE es[►: 4 act m ,-, a dr & Ie r 2. 3 4. p i 8 T ie,• 9 10 12 ADDITIONAL COMMENTS RELINOUIBHEDBYIAFFILIATION DATE, TIM4 ACCEPTEDBYIAFFILIATION'. DATE' TIME SAMPLE CONDITIONS e« try c �• ?"�'' ,.-� Cis upL SAMPLER NAME AND SIGNATURE ORIGINAL PRINT Name of SAMPLER: fir„CL 2 S SIGNATURE of SAMATE S P DMMMDlpned m y 'Important Note: By e4nlnq this form you we eccapfin Paws NET 30 day eavmenr rwrmn AM w r—im m rw. rn.m....r � S� -... ........__ __..._'Important_ - _. - _.. .... -- . -ndifioi:�1l�A R� 1e 0ipf 2Vace&alytical- Client Name?- _ �-fl - _ _ Project # 4�q 5 V30 Courier: ❑Fed Ex ❑UPS ❑ USPS Client El Commercial ❑ Pace Other :O #iof-'�'.. = y`'`` I� 4� � w — _ Custody Seal on Cooler/Box Present: ❑ yes no Seals intact: ❑ yes noroJ Q DatellA' 1701sNme .vF rlfA Packing Material: ❑ Bubble Wrap _,ell5ubble Bags ❑ None ❑Other Thermometer Used T060 / Type of Ic We Blue None IlKsamnles on ice, coolinq process has begun Cooler Temperature Ile- Biological is Frozen: Yes No NIA Date and rtials of person examining A conten t Tarnp should be above freezing to 6"C Comments: Chain of Custody Present: es ONo ❑NIA 1. Chair] of Custody Filled Out: Yes ❑No IINIA I Chain of Custody RBfinquished: es ONo ONIA 3, Sampler Name & Signature on COC: Yes ONo ❑NIA 4. Samples Arrived within Hold Time: Yes ONo ONIA 5. Short Hold Time Analysis (<72hr): OYes0ITo— ❑NIA 6. Rush Turn Around Time Requested: Iff Yes ONo ❑NIA 7. Sufficient Volume: - eADryes ONO ON/A 8. Correct Containers lased: 2Tes ONo 0:VA 9. -Pace Containers Used: Yes ONo ❑NIA Containers Intact: Yes ONo OWA 10. . Filtered volume received for Dissolved tests OYes ONo 641A 11. 9 & f A3-12ft . Sample Labels match COC: OYes f No El N/A 12. -Includes date/time/ID/Analysis Matrix: Ail containers needing preservation have been checked. s ONo ON1A 13, All containers needing preservation are found to be in es ONo ❑NIA compliance with EPA recommendation. exceptions: VOA, coliforni, TOC, 0&G, V111-ORO (water) Oyes ONo Initial when completed Samples checked for de chlorination: OYes ONo NIA 14_ Headspace in VOA Vials ( >6mm): OYes ONo RCA 15. Trip Blank Present: Oyes ONo . �!A 16. Trip Blank Custody Seals Present OYes ONo A Pace Trip Blank Lot # (if purchased)! NIA Client Notification/ Resolution: Field Data Required? Y I N I NIA Person Contacted: Date/Time: Comments/ Resolution: Project Manager Review: N[E{ _ Date: / ^/D - 00 Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office (i.e out of hold, incorrect preservative, out of temp, incorrect containers) ceAnalA(,(i! r ( . WW&Pab3hb&MM November 12, 2009 Mr. Tent' Carter Dixon Quick Coupling 332 Atando Ave Charlotte, NC 28206 RE: Project: DIXON QUICK COUPLING Pace Project No.: 9257130 Dear Mr. Carter: Pace Analytical Services, Inc. 2225 Riverside Or. Asheville, NC 28804 (828)254-7176 Pace Anaytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 Enclosed are the analytical results for sample(s) received by the laboratory on November 10, 2009. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. Inorganic Wet Chemistry and Metals analyses were performed at our Pace Asheville laboratory and Organic testing was performed at our Pace Huntersville laboratory unless otherwise footnoted. All Microbiological analyses were performed at the laboratory where the samples were received. If you have any questions concerning this report, please feel free to contact me. Sincerely, Brandon Helton brandon.helton@pacelabs.com Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical: Services, Inc.. (704)875-9092 Page 1 of 10 Pace Analytical Services, Inc. Pace Analytical Services, Inc. CeArW " 2225 Riverside Dr. 9800 KEnceyAve. Suite 100 Wimpamliftcom Asheville. NC 28804 Huntersv ilie, NC 28078 (828)254-7176 (704)875-9092 CERTIFICATIONS Project: DIXON QUICK COUPLING Pace Project No.: 9257130 Charlotte Certification IDS West Virginia Certification M 357 North Carolinabrinking Water Certification #: 37706 Virginia Certification M 00213 North Carolina Field Services Certification #: 5342 Connecticut Certification #: PH-0104 North Carolina Wastewater Certification M 12 Florida/NELAP Certification #: E87627 Pennsylvania Certification M. 68-00784 Kentucky UST Certification #: 84 South Carolina Certification #: 990060001 Louisiana/LELAP Certification M 04034 South Carolina Drinking Water Cart. #: 990060003 New Jersey Certification #: NCO12 Tennessee Certification #: 04010 Asheville Certification IDS West Virginia Certification #: 356 North Carolina Wastewater Certification #: 40 Florida/NELAP Certification #: E87648 Pennsylvania Certification #: 68-03578 Louisiana/LELAP Certification #: 03095 South Carolina Bioassay Certification #: 99030002 Massachusetts Certification M M-NCO30 South Carolina Certification #: 99030001 New Jersey Certification #: NC011 Tennessee Certification #: 2980 North Carolina Bioassay Certification #: 9 Virginia Certification #: 00072 Connecticut Certification M PH-0106 North Carolina Drinking Water Certification #: 37712 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 2 of 10 cca� w r �'�z /��Ce W*W'0W8AftCoM Project: DIXON QUICK COUPLING Pace Project No.: 9257130 Lacs ID Sample ID 9257130001 SAMPLE LOCATION 2 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Method EPA1664A EPA 200.7 EPA 9D40 SM 2540D REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Analysts CLW JMW DMN DMN Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (104)875-9092 Analytes Reported Laboratory 1 PASI-C 1 PASI-A 1 PASI-A 1 PASI-A Page 3 of 10 a Cel4lla%/fIC81 trwr�paceJa6soam Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (626)254-7176 ANALYTICAL RESULTS Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: DIXON QUICK COUPLING Pace Project No.: 9257130 Sample: SAMPLE LOCATION 2 Lab ID: 9267130001 Collected: 11/10/09 11:45 Received: 11/10/09 13:00 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664A Oil and Grease ND mg/L 5.0 1 11/11/09 08:52 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 314 ug/L 5.0 1 11/1110913:20 1111110917:26 7439-92-1 2540D Total Suspended Solids Analytical Method: SM 2540D Total Suspended Solids 102 mg/L 8.3 1 11/11/09 20.45 9040 pH Analytical Method: EPA 9040 pH 7.5 Std. knits 0.10 1 11/11/09 18:35 Date: 11/122009 02:51 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. t W H6 Page 4 of 10 ,�aceAfflocal` wwwpxaft&wm Project: DIXON QUICK COUPLING Pace Project No.: 9257130 QC Batch: WET110446 QC Batch Method: EPA 9040 Associated Lab Samples: 9257130001 SAMPLE DUPLICATE: 365174 Pa rameter Units pH Date: 11/12/2009 02:51 PM Std. Units Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NO 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: EPA 9040 Analysis Description: 9040 pH 9257130001 Dup Result Result RPD Qualifiers 7.5 7.5 0 H6 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Pace Anatytical Services, Inc. 9800 KinceyAve, Suite 100 Huntersville, NO 28078 (704)875-9092 Page 5 of 10 yAW.Pacefebao= Project: DIXON QUICK COUPLING Pace Project No.: 9257130 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA QC Batch: MPRP/5368 Analysis Method: EPA 200.7 QC Batch Method: EPA 200.7 Analysis Description: 200.7 MET Associated Lab Samples: 9257130001 METHOD BLANK: 364655 Associated Lab Samples: 9257130001 Matra: Water Blank Reporting Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Parameter Units Result Limit Analyzed Qualifiers Lead ug/L ND 5.0 11/1110916:50 LABORATORY CONTROL SAMPLE: 364656 Spike LIDS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Lead ug/L 500 523 105 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 364657 364658 MS MSD 9257127001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone, Result Result % Rec % Rec Limits RPD Qual Lead ug/L 194 500 500 648 651 91 91 70-130 0 SAMPLE DUPLICATE: 364659 Parameter Lead Date: 11/12200902:51 PM 9257127002 Dup Units Result Result ug/L 39.3 38.2 RPD Qualifiers 3 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. •9 ,N ACCOAO Page 6 of 10 Project: DIXON QUICK COUPLING Pace Project No.: 9257130 QC Batch: GCSV/6665 QC Batch Method: EPA 1664A Associated Lab Samples: 9257130001 METHOD BLANK: 364674 Associated Lab Samples: 9257130001 Parameter Units Oil and Grease mg/L LABORATORY CONTROL SAMPLE: 364675 Parameter Units Oil and Grease mg/L MATRIX SPIKE SAMPLE: 364676 Parameter Units Oil and Grease mg/L Date: 11/12/2009 02:51 PM Pace Analytical Services, Inc. 2225 Riverside Or. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: EPA 1664A Analysis Description: 1664 HEM, Oil and Grease Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 11/11/0908:51 Spike LCS LCS Cone. Result °% Rec 40 36.7 92 9257130001 Spike MS Result Conc. Result ND 48.8 43.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Pace Analytical Services, Inc. 9B00 10nceyAve. Suite 100 Huntersville, NC 2BO78 (704)875-9092 °% Rec Limits Qualifiers 78-114 MS °% Rec °% Rec Limits Qualifiers 83 78-114 Page 7 of 10 I"A l al lcQ! wrrw.p webbs.= Project: DIXON QUICK COUPLING Pace Project No.: 9257130 QC Batch: WET/10448 QC Batch Method: SM 2540D Associated Lab Samples: 9257130001 METHOD BLANK: 365279 Associated Lab Samples: 9257130001 Parameter Units Total Suspended Solids mg/L LABORATORY CONTROL SAMPLE: 365280 Parameter Units Total Suspended Solids mg/L SAMPLE DUPLICATE: 365281 Parameter Total Suspended Solids Date: 11/12/2009 02:51 PM Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis Description: 2540D Total Suspended Solids Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 11/11/0920:45 Spike LCS Conc. Result 250 260 9257130001 Dup Units Result Result mg/L 102 108 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 . (704)875-9092 LCS % Rec % Rec Limits Qualifiers 104 80-120 RPD Qualifiers 6 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 8 of 10 'rAeAnWid� QUALIFIERS Project: DVON QUICK COUPLING Pace Project No.: 9257130 DEFINITIONS Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (628)254-7176 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 ` (704)875-9D92 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit MDL -Adjusted Method Detection Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes toAzobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrb( Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. U - Indicates the compound was analyzed for, but not detected. LABORATORIES PASI-A Pace Analytical Services -Asheville PASI-C Pace Analytical Services - Charlotte ANALYTE QUALIFIERS H6 Analysis initiated more than 15 minutes after sample collection. Date: 1111W009 02:51 PM REPORT OF LABORATORY ANALYSIS Page 9 of 10 This report shall not be reproduced, except in full, without the written consent of Pace Anayticai Services, Inc.. ,y CCO� 4LE S� 1 Y C n3V1Cal f1 "w»:"O. E Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: DIXON QUICK COUPLING Pace Project No.: 9257130 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 i (704)875-9092 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 9257130001 SAMPLE LOCATION 2 EPA200.7 MPRP15368 EPA200.7 ICP/4979 9257130001 SAMPLE LOCATION 2 EPA 1664A GCSV16665 9257130001 SAMPLE LOCATION 2 EPA 9040 WEi-110446 9257130001 SAMPLE LOCATION 2 SM 2540D WETl113448 Date: 11/12/2009 02:51 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the mitten consent of Pace Analytical Services, Inc.. Page 10 of 10 �PaceAnal ical' CHAIN -OF -CUSTODY 1 Analytical Request Document The Chain -of -Custody is a LEGAL DOCUMENT. All relevant fields must be completed accurately. Section A Section 6 Section C Page: o! Required Client Information: Required Project Information: Invoice Information: t �} �'} p q '] Go any: Report To: err Attontlon• a QP 1 3 3 4 1 J 133413 XO e{ f e r r _C Address: Copy To: Company Name: REGULATORY AGENCY i. •, Crha_lot t Address: r NPDES i— GROUND WATER [" DRINKING WATER r UST 1— RCRA r OTHER E it To: Purchase Order No.: Pau Ouate K T; n Qv t C+ +ty Reference: Phone: Fax. / Project Name: QJ i Pace Pm lei �� IS or, Locatlon 3 S Ta� �o � ct( C�'s -e e t •-, Manager: , e- 5TATE: Requested Due DstslrAT: Aspkp Project Number. Peas Profile s, ! ' ReOested Analysis Filtered (YIN) Section D Matrix Codes a x Requlred0lontlnformsiYw MATRIx !CODE 8 M COLLECTED Preservatives s. Drinking Water DW 0 b Water WT WatBf � U � COMPOSITE START COMPOSITE ENG1GRAn W z PW Product SoIVSoGd SL p ex► _ O SAMPLE 1D Oil wP a Wipe (A.Z. 0-9 1; ? Air AR w a z H Sample IDS MUST BE UNtOUE Tissue TS O L) W rar D Z _ L U Other OT ii z =O A4 kTr If 0 a ry p Z _ Ci u�iv N� C C y DATE TIME PATE TIME U) # C T -T R Z [9 Z M O y 61 it pace Pro ect No./ Lab I.D. la 2 3 4 S 8 7 S 9 1e 11 12 ADDITIONAL COMMENTS RELINQUISHED BY t AFFILIATION DATE TIME ACCEPTED BY! AFFILIATION DATE TIME SAMPLE CONDITIONS C P r w-r JXOh 44c �� SS Z V /`/ ORIGINAL SAMPLER NAME AND SIGNATURE U `o a PRINT Name of SAMPLER: m F11:MM1DDlYY � SIGNATURE of SAMPLE DATE Signed : 'Important Nate; By sVrdng Wo farm you are accepting Pace's NET 30 day payment terms and agreeing to Into charges of 1.5% oar mnath fnr .nv Ynvnlr...va —Id A.Wvn a�•— ! 3ceAnalytical Client Name: " oJJ ay{ Project # g2-5'�o FS Courier ❑ Fed Ex ❑ UPS ❑ USPS [� Client ❑ Commercial ❑ Pace Other ;Optlonaf: k' Custody Seal on Cooler/Box Present. (❑ yes no Seals intact: ❑ yes no pkotF Date�l`J A R�Q� lvan-te �,�NIE�, Packing Material: ❑ Bubble Wrap Bubble Bags ❑ Nan ❑other fit, Thermometer Used T060 Type of Ice- Wet Blue None d� 1 Samples on ice, cooling process has begun Cooler Temperature Temp should be above freezing to 6°C ~� Biological Tissue is Frozen: Yes t r 1Z Comments: Date and I i W,,p e so examining contents. 0 Chain of Custody Present: Yes ❑No ❑NIA 1. Chain of Custody Felted Out: Yes ONO ❑NIA 2. Chain of Custody Relinquished: Yes ❑No ❑NIA 3. Sampler Name & Signature on COC_ Yes ONO ❑NIA 4. Samples Arrived within Hold Time: Yes ONO ❑NIA 5. Short Hold Time Analysis (<72hr): Dyes No ❑NIA 6, Rush Turn Around Time Requested: Ayes I e7f OW100 7. Sufficient Volume: r Yes ONO ❑NIA 8. Correct Containers Used: -Pace Containers Used: Yes VIYeS LINO ONO- 0NIA ❑NIA 9. Containers Intact: Yes ❑No ❑NIA 10. . Filtered volume received for Dissolved tests Dyes ONO &NIA 11. Sample Labels match COC.. -includes date/time/ID/Analysis Matrix: ❑Yes KNo ❑NIA 12, All containers needing preservalion have been checked. . All containers needing pre5.ervation are found to be in compliance with EPA recommendation. exceptions: VOA, colirorm. TOc, O&G, WI-DRO (water) Yes �l es / 0Yes ❑No ❑No ❑No ❑NIA ❑NIA 13. Initial when completed Samples checked for dechlorination: ❑Yes ❑No MA 14. Headspace in VOA Vials ( >6mm): ❑Yes ONO NIA 15, Trip Blank Present: Trip Blank Custody Seals Present Pace Trip Blank Lot # (i€ purchased): N/A Dyes Oyes ❑No . ❑No �NIA t�INIA 16. Client Notification/ Resolution: Field Data Required? Y I N I N/A Person Contacted: Comments/ Resolution: Date/Time: Project Manager Review; Bm N Date: /Z — r7 D g Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form wilt be sent to the North Carolina DEHNR Certification Office ( i.e out of hold, incorrect preservative, out of temp, incorrect containers) Pace Analytical Services, Inc. Pace Analytical Services, Inc. ,�aceAnaVical@ 2225 Riverside Dr. 9800 Kincey Ave. Suite 100 wwa,pacalab .00m Asheville, NC 28804 Huntersville, NC 28078 (828)254-7176 (704)875-9092 Project: DIXON QUICK COUPLING Pace Project No.: 9259083 Charlotte Certification IDs 9800 Kinoey Ave. - Ste 100 Huntersville, NC 28078 West Virginia Certification #: 357 Connecticut Certification #: PH-0104 Fiorida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana/LELAP Certification #: 04034 New Jersey Certification #: NCO12 North Carolina Drinking Water Certification #: 37706 Asheville Certification IDs 2225 Riverside Dr. Asheville, NC 28804 Connecticut Certification #: PH-0106 Louisiana/LELAP Certification #: 03095 Massachusetts Certification #: M-NC030 New Jersey Certification #: NC01i North Carolina Bioassay Certification #: 9 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 CERTIFICATIONS North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 Pennsylvania Certification #: 68-00784 South Carolina Certification #: 990060001 South Carolina Drinking Water Cert. #: 990060003 Tennessee Certification #: 04010 Virginia Certification #: 00213 Pennsylvania Certification #: 68-03578 South Carolina Bioassay Certification #: 99030002 South Carolina Certification #: 99030001 Tennessee Certification #: 2980 Virginia Certification #: 00072 West Virginia Certification #: 356 Florida/NELAP Certification #: E87648 REPORT OF LABORATORY ANALYSIS This report shall not tre reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. .pco a r Page 2 of 10 IeAnalytical e wwwpacehiftcam Project: DIXON QUICK COUPLING Pace Project No.: 9259083 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Pace Analytical Services, Inc. 9800 Kinoey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 9259083001 SAMPLE LOCATION NO 2 EPA 1664A CLW 1 PASI-C EPA2001 JMW 1 PASI-A SM 2540D TEE 1 PASI-A EPA 9040 DMN 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. A. Page 3 of 10 �eMalytical www.Pacalabsoom Project: DIXON QUICK COUPLING Pace Project No.: 9259083 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Sample: SAMPLE LOCATION NO 2 Lab ID: 9259083001 Collected: 12/08/09 16:50 Received: 12/09/09 08:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No_ Qual HEM, Oil and Grease Analytical Method: EPA 1664A Oil and Grease 8.4 mg1L 5.0 1 12/09/09 14:01 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 103 ug/L 5.0 1 12/10/09 10:00 12/10/09 13:59 7439-92-1 2540D Total Suspended Solids Analytical Method: SM 2540D Total Suspended Solids 24.5 mg/L 22.7 1 12/10/09 17:02 9040 pH Analytical Method: EPA 9040 pH 7.2 Std. Units 0.10 1 12/10/09 21:35 Date: 12/11/2009 02:17 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. H6 Page 4 of 10 aceAnalytical WWW..P8cgk &00M Project: DIXON QUICK COUPLING Pace Project No.: 9269083 QC Batch: GCSV/6819 OC Batch Method: EPA 1664A Associated Lab Samples: 9259083001 METHOD BLANK: 376789 Associated Lab Samples: 9259083001 Parameter Units Oil and Grease mg/L LABORATORY CONTROL SAMPLE: 376790 Parameter Units Oil and Grease mg/L MATRIX SPIKE SAMPLE: 376791 Parameter Units Oil and Grease mg1L Date: 12/11/2009 02:17 PM Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: EPA 1664A Analysis Description: 1664 ITEM, Oil and Grease Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 12/09/09 14:01 Spike LCS LCS Cone. Result % Rec 40 34.8 87 9259106005 Spike MS Result Cone. Result ND 40 37.2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 % Rec Limits Qualifiers 78-114 MS % Rec % Rec Limits Qualifiers 93 78-114 Page 5 of 10 1��alceAnalyfibale t www.pacelab&OOM I Project: DIXON QUICK COUPLING Pace Project No.: 9259083 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 26804 (828)254-7178 QUALITY CONTROL DATA QC Batch: MPRP/5512 Analysis Method: EPA 200.7 QC Batch Method: EPA 200.7 Analysis Description: 200.7 MET Associated Lab Samples: 9259083001 METHOD BLANK: 377211 Matrix: Water Associated Lab Samples: 9259083001 Blank Reporting Pace Analytical Services, Inc. 9B00 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Parameter Units Result Limit Analyzed Qualifiers Lead ug/L ND 5.0 12/1010913:52 LABORATORY CONTROL SAMPLE: 377212 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Lead ug/L 500 510 102 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 377213 377214 MS MSD 9259083001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Lead ug/L 103 500 500 607 607 101 101 70-130 0 SAMPLE DUPLICATE: 377215 Parameter Lead Date: 12/11/2009 02:17 PM 9259116001 Dup Units Result Result ug/L ND ND RPD Qualifiers REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. ,: Page 6 of 10 aceftlXical s wwvpacebb&=n Project: DIXON QUICK COUPLING Pace Project No.: 9259083 QC Batch: WET110769 QC Batch Method: SM 2540D Associated Lab Samples: 9259083001 METHOD BLANK: 377645 Associated Lab Samples: 9259083001 Parameter Units Total Suspended Solids mg/L LABORATORY CONTROL SAMPLE: 377646 Parameter Units Total Suspended Solids mg/L SAMPLE DUPLICATE: 377647 Parameter Total Suspended Solids Date: 12/11/2009 02:17 PM Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis Description: 2540D Total Suspended Solids Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28076 (7041875-9092 Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 12/10/09 17:01 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 250 236 94 80-120 9259083001 Dup Units Result Result RPD Qualifiers mg/L 24.5 25.5 4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 7 of 10 C ARaljftal` r wry PzCek arom 1 Project: DIXON QUICK COUPLING Pace Project No.: 9259083 QC Batch: VVET110767 QC Batch Method: EPA 9040 Associated Lab Samples: 9259083001 SAMPLE DUPLICATE: 377610 Parameter Units pH Date: 12/11 /2009 02:17 PM Std. Units Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Analysis Method: EPA 9040 Analysis Description: 9040 pH 9258433001 Dup Result Result RPD Qualifiers 7.4 7.4 0 H6 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. e� - ii Pace Analytical Services, Inc. 9800 KinceyAve, Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 10 1��I=Analyfical* f wrn pncel8tk&cam t QUALIFIERS Project: DIXON QUICK COUPLING Pace Project No.: 9259083 DEFINITIONS Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Hunlersville, NC 28078 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. U - Indicates the compound was analyzed for, but not detected. LABORATORIES PASI-A Pace Analytical Services - Asheville PAST-C Pace Analytical Services - Charlotte ANALYTE QUALIFIERS HB Analysis initiated more than 15 minutes after sample collection. (704)875-9092 Date: 12/11/2009 02:17 PM REPORT OF LABORATORY ANALYSIS Page 9 of 10 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. ifieh& ac6Anayical xww.pa A%bs.aam Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: DIXON QUICK COUPLING Pace Project No.: 9259083 Pace Analytical Services, Inc. , 9800 Kincey Ave. Suite 100 , Huntersville, NC 28078 • (704)875-9092 Lab ID Sample ID QC Batch Method QC Batch Analytical Method 9259083001 SAMPLE LOCATION NO 2 EPA 1664A GCSVI6819 9259083001 SAMPLE LOCATION NO 2 EPA 200.7 MPRP15512 EPA 200.7 9259083001 SAMPLE LOCATION NO 2 SM 2540D WETl10769 9259083001 SAMPLE LOCATION NO 2 EPA 9040 WET110767 Date: 12/11/2009 02:17 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Analytical Batch ICP/5110 Page 10 of 10 aceAnal ical' eww eealeh..eem CHAIN -OF -CUSTODY 1 Analytical Request Document The Chain -of -Custody Is a LEGAL DOCUMENT. All relevant fields must be completed accurately. Section A Section B Section C Page: of Required Client Information: Required Project Information: Invoice Information: Company: A Report ToAttention; 1326911 f Addre Copy,Tc: Company Nam I� REGULATORY AGENCY +Q OV1 J O r Address: NPDEs r GROUND WATER F-• DRINKING WATER r UST r— RCRA r OTHER E all To: r Purchase Order NO.: Pace Quale A 3i I r►t s Reference: Phone; F ><: + ;CA `rr jact Name; Pete Project Site LOcagon O QM' Manager. 5Ti{TE: R*qursted s a Project Number. Pace Pmflle q 3�1 J �I ( Requested Analysis Filtered (YIN) Section D Matrix Codes d z Required Client Information MATRIx !CODE 9 COLLECTED Preservatives .r Drinking Water DW z Water WT Produ,:tWaste WW Soillsolid SL L) 0 COMPOSITE START COMPOSITE END/GRAB J SAMPLE ID O1;Aa ,°�, i3 W r c (A-z, as r; I Air AR uw uj a r1 Z bi J a Sample IDs MUST BE UNIQUE Tissue TS O w -* Other OT U X O � U _ = O In�y L d r :G yy yet F s O C ry 2 U N to _ 2 2 DATE TIME DATE TIME r���)II at T 2 Z Z 2 � :J y IY Pace Project No./ Lab I.D. 1 v K sAzu c.0a. r e "T 3 rtis 4 5 S 7 e s �a 12 ADDITIONAL COMMENTS RELIN4Uk$HED BY AFFILIATION DATE TIME ACCEPTED BY 1 AFFiLIAT10N DATE TIME SAMPLE CONDITION$ try AW t1��1 ua�,G I (O d I-O� ► , �t1 r �j ���'x . +--' 'aP (.J SAMPLER NAME AND SIGNATURE ORIGINAL PRINT Nam* of SAMPLER: �,�, DATE Signed SIGNATURE of SAMPL y03 -V.A! (MMIDDIYY): 'Impartam Note: By signing this farm you are accepting Pece's NET 30 day oeymnnt In"11 end nnr..lna m Ion. 1h.—. m t n.c ^...i 1— t..—1I^.,1'^--'-'.- < rs afpre indMO*11�vir' ec T _a ceAnalytica!' Client Name:-. Project # 17Z5 7TZ'7 Courier: ❑ Fed Ex UPS LISPS Client ❑ ❑ ❑Commercial ❑ Pace Other OptionaC• Custody Seal on Cooler/Box Present: ❑ yes no Seals intact: ❑ yes no P ;g Dui Datef t to :_ Packing Material: ❑ Bubble Wrap Bubble Bags" o None _We❑Other ��_ Thermometer Used T060 Type of Ice:(;et) I Blue None /f Samnles on ice coolino process has beaun Cooler Temperature mac.. I BiologicalTissue is Frozen: Yes Na NIA Date and Initials of person examining C contents: Temp should �e above freezing to 6'C Comments: Chain of Custody Present: Yes ❑No ❑NIA 1, Chain of Custody Filled Out: es QNo ❑NrA 2_ Chain of Custody Relinquished: Yes ❑No ❑NIA I Sampler Name & Signature on COC: Yes ❑No ❑NIA 4, Samples Arrived within Hold Time: ❑Yes ❑No ❑N!A 5. A p cyfC. Ic- C E or Short Hold Time Analysis (<72hr): ❑Yes-,210 ❑NIA 6. Rush Turn Around Time Requested: e<Ye�s t]No ❑N/A 7. Sufficient Volume: Yes ❑No ❑N/A 8. Correct -Containers Used: Yes ❑No ❑N1A 9• -Pace Containers Used: Yes ❑Na. ❑N1A Containers Intact: ,,4�es ❑No ❑N/A 10. . Filtered volume received for Dissolved tests ❑Yes ❑No A 11. ' Sample Labels match COC: &a es ONo ❑NIA 12. -includes dateltime/ID/Analysis Matrix: All containers needing preservation have been checked, Yes ❑No ❑NIA 13, ' All containers needing preservation are found to be in ❑No ©N1A compliance with EPA recommendations exceptions: VOA, coliform, TOC, O&G, WI-DRO(water) ❑Yes ❑No initial.when completed Samples checked for dechforination: ❑Yes ❑No NIA 14. Headspace in VOA Vials (>6mm): Dyes ❑No 2rNIA 15. Trip Blank Present: Dyes ❑No A . Trip Blank Custody Seals Present Dyes ❑No NIA Pace Trip Blank Lot # (if purchased): NIA Client Notification/ Resolution: Field Data Required? Y / N / NIA Person Contacted: Comments/ Resolufion: Date/Time: Project Manager Review: �56,% 1 Date: 11 -1 d • O R Gl'e' Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office ( i.e out of hold, incorrect preservative, out of temp, incorrect containers) aceARayicaf. wmpsceladaccm Project: SAMPLING 11/10 Pace Project No.: 9257127 Asheville Certification IDs West Virginia Certification #: 356 Virginia Certification #: 00072 Tennessee Certification #: 2980 South Carolina Certification #: 99030001 South Carolina Bioassay Certification M 99030002 Pennsylvania Certification #: 6"3578 Connecticut Certification #: PH-0106 Pace Analytical Services, Inc. Pace Analytical Services, Inc. 2225 Riverside Dr. 9800 Kincey Ave. Suite 100 Asheville, NC 28804 Huntersville, NC 28078 (828)254-7176 (704)875-9092 CERTIFICATIONS North Carolina Drinking Water Certification #: 37712 North Carolina Bioassay Certification #: 9 New Jersey Certification* NC011 Massachusetts Certification #: M-NCO30 Louisiana/LELAP Certification #: 03095 FloridalNELAP Certification #: E87648 North Carolina Wastewater Certification M 40 REPORT OF LABORATORY ANALYSIS Page 2 of 7 This report shall not be reproduced, except in hull, without the written consent of Pace Analytical Services, Inc.. �lne`= f . aceAnaljftal' kwxrps.oarr! Project: SAMPLING 11/10 Pace Project No_: 9257127 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Ana"s Lab ID Sample ID Method Analysts Reported Laboratory 9257127001 LOADING DOCK EPA 200.7 JMW 1 PASI-A 9257127002 BEHIND WAREHOUSE EPA 200.7 JMW 1 PASI-A 9257127003 ROOF AT SHIPPING EPA 200.7 JMW 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. CCO� Page 3 of 7 f• • ® Pace Analytical Services, Inc. Pace Analytical Services, Inc. �acl a Q%j',ji1/tlJsall2225 Riverside Dr. 9800 KinceyAve. Suite 100 uwna!lcabbb&camaJr Asheville, NC 28804 Huntersville, NC 28078 (828)254-7176 (704)875-9092 ANALYTICAL RESULTS Project: SAMPLING 11/10 Pace Project No.: 9257127 Sample: LOADING DOCK Lab ID: 9257127001 Collected: 11/10/09 00:00 Received: 11/10/09 13:00 Matrix:Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 194 ug/L 5.0 1 11/11/0913:20 11/11/0916:58 7439-92-1 Sample: BEHIND WAREHOUSE Lab ID: 9257127002 Collected: 11/10/09 00.00 Received: 11/10/09 13:00 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 39.3 ug/L 5.0 1 1111110913:20 11/1110917:14 7439-92-1 Sample: ROOF AT SHIPPING Lab ID: 9257127003 Collected: 11/10/09 00:00 Received: 11/10/09 13:00 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No, Qual 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead 26.0 ug/L 5.0 1 11/1110913:20 1111110917:23 7439-92-1 Date: 11/12/2009 02:51 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. uiJ_J: Page 4 of 7 e Pace Analytical Services, Inc. Pace Services, Inc. �aceAnayicaAnalytical l 2225 Riverside Dr. 9800 Kincey Ave. Suite 100 xwwpsmwmcnm Asheville, NC 28804 Huntersville, NC 25078 (828)254-7176 (704)875r9092 QUALITY CONTROL DATA Project: SAMPLING 11/10 Pace Project No.: 9257127 QC Batch: MPRP/5368 Analysis Method: EPA 200.7 QC Batch Method: EPA 200.7 Analysis Description: 200.7 MET Associated Lab Samples: 9257127001, 9257127002, 9257127003 METHOD BLANK: 364655 Matrix: Water Associated Lab Samples: 9257127001, 9257127002, 9257127003 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Lead ug/L ND 5.0 1111110916:50 LABORATORY CONTROL SAMPLE: 364656 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Lead ug/L 500 523 105 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 364657 364658 MS MSD 9257127001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Lead ug/L 194 500 500 648 651 91 91 70-130 0 SAMPLE DUPLICATE: 364659 9257127002 Dup Parameter Units Result Result RPD Qualifiers Lead ug/L 39.3 38.2 3 Date: 11/12/2009 02:51 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in hull, without the written consent of Pace Analytical Services, Inc.. Page 5 of 7 �eAnaoicale WWWpeceftbimm QUALIFIERS Project: SAMPLING 11/10 Pace Project No.: 9257127 DEFINITIONS Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Pace Analytical Services, Inc. 9800 Kinney Ave. Suite 100 Huntersville. NC 28078 (704)875-9092 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 fisted analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. U - Indicates the compound was analyzed for, but not detected. LABORATORIES PASI-A Pace Analytical Services - Asheville Date: 11/12/2009 02:51 PM REPORT OF LABORATORY ANALYSIS Page 6 of 7 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. ,�aceAnalytical www.pecelabscom Project: SAMPLING 11110 Pace Project No.: 9257127 Pace Analytical Services, Inc. Pace Analytical Services, Inc. 2225 Riverside Dr. 9800 Kincey Ave. Suite 100 Asheville, NC 28804 Huntersville, NC 28078 (B28)254-7176 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 9257127001 LOADING DOCK EPA 200.7 MPRP/5368 EPA 200.7 ICP/4979 9257127002 BEHIND WAREHOUSE EPA 200.7 MPRPl5368 EPA 200.7 ICP/4979 9257127003 ROOF AT SHIPPING EPA 200.7 MPRP/5368 EPA 200.7 ICP/4979 Date: 11/12/200902:51 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 7 of 7 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources ,,,, : , . Gregory J; Thbrpe, Ph.D. "Acting Director Division bf Water Quality December 27, 2001 RANDALL J MULLINS PERFECTING COUPLING CO PO BOX 790068 CHARLOTTE, NC 28206 Subject: NPDES Stormwater Permit Renewal PERFECTING COUPLING CO COC Number NCG030283 Mecklenburg County Dear Permittee: APR T 0 2302 Your facility is currently covered for stormwater discharge under General Permit NCG030000. This permit expires on August 31, 2002. The Division staff is currently in the process of rewriting this permit and is scheduled to have the permit reissued by late summer of 2002. Once the permit is reissued, your facility would be eligible for continued coverage under the reissued permit. In order to assure your continued coverage under the general permit, you must apply to the Division of Water Quality (DWQ) for renewal of your permit coverage.. To make this renewal process easier, we are informing you in advance that your permit will be expiring. Enclosed you will find a General Permit Coverage Renewal Application Form. The application must be completed and returned by March 4, 2002 in order to assure continued coverage under the general permit. Failure to request renewal within this time period may result in a civil assessment of at least $250.00. Larger penalties may be assessed depending on the delinquency of the request. Discharge of stormwater from your facility without coverage under a valid stormwater NPDES permit would constitute a violation of NCGS 143-215.1 and could result in assessments of civil penalties of up to $10,000 per day. Please note that recent federal legislation has extended the "no exposure exclusion" to all operators of industrial facilities in any of the 1 I categories of "storm water discharges associated with industrial activity," (except construction activities). If you feel your facility can certify a condition of "no exposure", i.e. the facilty industrial materials and operations are not exposed to stormwater, you can apply for the no exposure exclusion. For additional information contact the Central Office Stormwater Staff member listed below or check the Stormwater & General Permits Unit Web Site at http://h2o.enr.state.nc.us/su/stormwater.htmi If the subject stormwater discharge to waters of the state has been terminated, please complete the enclosed Rescission Request Form. Mailing instructions are listed on the bottom of the form. You will be notified when the rescission process has been completed. If you have any questions regarding the permit renewal procedures please contact Mike Parker of the Mooresville Regional Office at 704-663-1699 or Bill Mills of the Central Office Stormwater Unit at (919) 733-5083, ext. 548 Sincerely, Bradley Bennett, Supervisor Stormwater and General Permits Unit cc: Central Files Mooresville Regional Office T NCDENR i i ' iJ N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Customer Service 1-800-623-7748 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality August 23, 2002 MARK N HALL PERFECTING COUPLING CO PO BOX 790068 CHARLOTTE, NC 28206 Subject: NPDES Stormwater Permit Renewal PERFECTING COUPLING CO COC Number NCG030283 Mecklenburg County Dear Permittee: In response to your renewal application for continued coverage under general permit NCG030000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: * A new Certificate of Coverage * A copy of General Stormwater Permit NCG030000 * A copy of the Analytical Monitoring Form (DMR) * A copy of a Technical Bulletin for the general permit Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Bill Mills of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 548 cc: Central Files Stormwater & General Permits Unit Files Mooresville Regional Office Sincerely, Bradley Bennett, Supervisor Stormwater and General Permits Unit NC DEPT. O AN0N'A t•-r?AL SCO"URCES AUG 2 9 2002 'ATA NCW R N. C. Division of Waler Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Customer Service 1- 800-623-7748 I*. NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Mr. Scott Clark, General Manager 332 Atando Ave. Charlotte, NC 28206 Dear Mr. Clark: Division of Water Quality Coleen H. Sullins Director April 6, 2010 Subject: Stormwater Monitoring Results Dixon Quick Coupling 332 Atando Ave. NPDES Stormwater Permit NCG NCG030000 Certificate of Coverage — NCG030283 Mecklenburg County Dee Freeman Enclosed are the monitoring results from the samples collected of the discharge from Stormwater Outfall 001 at the subject facility. The samples analyzed were grab samples collected during the sampling investigation performed on November 10, 2009, by Andrew Martin of Charlotte -Mecklenburg Storm Water Services_ This sampling investigation was conducted as part of a cooperative working agreement between Mecklenburg County and the Division of Water Quality. In addition, the inspection was conducted on behalf of the City of Charlotte in compliance with the City's NPDES Permit, NCS000240, Part II Section H. The enclosed monitoring results indicate that the stormwater discharged on November 10, 2009, contained an elevated concentration of lead compared with the benchmark values contained in Stormwater general permit NCG030000. In addition, elevated concentrations of zinc and copper were also detected as compared with the Division's benchmarks developed.for individual stormwater permits (copper - 7 µg/L; zinc - 67 µg/L). These values also exceed the applicable stream standards for toxic substances (copper - 7 µglL; zinc - 50 µg/L). Since the stormwater sample was not collected in -stream, the stream standards do not apply; however, these standards can be used to indicate the potential of your runoff to impact the receiving stream. Please review the requirements of your stormwater permit and take the required stepslactions to reduce the concentration of lead, copper, and zinc leaving your site. Through the.development and, implementation of stormwater management programs it is the Division of Water Quality's expectation that stormwater discharges at industrial sites covered by NPDES stormwater permits do not impact receiving waters. The enclosed results should be self-explanatory; however should you have any questions concerning the sampling results or have any questions regarding your permit, please do not hesitate to contact Andrew Martin with CMSWS or Ms. Marcia Allocco of the Division of Water Quality at (704) 235-2204. Sincerely, for Robert B_ Krebs, Regional Supervisor. Surface Water Protection Section Mooresville Regional Office cc: Water Quality Central Files Craig Miller, City of Charlotte Rusty Rozzelle, MCWQP Mooresville Regional Office Location: 610 Fast Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service: 1-877-623-6748 Internet http!Yportal.ncdenr.cr;'weblwq OfiE NorthCarona V17t%1r71111 Scott Clark, Dixon Quick Coupling Stormwater Sampling, Page 2 April 6, 2010 ADDENDUM The National Pollutant Discharge Elimination System (NPDES) program was established under the federal Clean Water Act and then delegated to the Division of Water Quality for implementation in North Carolina. The NPDES permitting program for stormwater discharges was established in 1990. Phase 1 focuses on site and operations planning to reduce pollutant sources. Through the NPDES permitting program industrial facilities that fall into one of the subject ten categories are required to obtain permit coverage under a general permit or an individual permit, depending upon the facilities SIC code and the industrial activity occurring at the facility. There are currently 19 active general stormwater permits in North Carolina. One condition that is applicable to both the general permits and individual stormwater permits is the requirement to develop and implement site -specific comprehensive Stormwater Pollution Prevention plans (SPPP). These plans are required to include a comprehensive evaluation of the site and operations to reduce pollutant sources and prevent pollutant discharge. Copies of the general permits and accompanying documents can be accessed from the following webpage: http://h2o.enr,state.nc.us/su/Forms_Documents.htm_ Permit text, technical bulletins, discharge monitoring forms, and a Notice of Intent [which is the application for coverage under a NPDES General Stormwater Permit] can be found on this website. The following items are a subset of permit requirements and are listed to assist you and help bring your attention to certain permitting issues, process and condition requirements of your permit_ Please see the above mentioned website to obtain a copy of the permit so you may fully comply with all the conditions therein. Failure to properly comply with conditions of the permit, like those buffeted below, is a violation(s) of the permit and subject to civil penalty assessment(s) of up to $25,000.00 per day. • Industrial facilities that fall into one of the subject ten categories are required to obtain permit coverage under a general NPDES stormwater permit or an individual NPDES stormwater permit • All persons desiring to have facilities covered by a General Permit must register with the Division of Water Quality (DWQ) by filing of a Notice of Intent (NOI) and Applicable Fees. • This Notice of Intent (NOI) must be submitted and a Certificate of Coverage issued prior to any discharge of stormwater associated with the industrial activity, process wastewater, andlor mine dewatering. • Once the Notice of Intent is received, DWQ will review and determine whether a Certificate of Coverage (COC) may be issued. If this Certificate of Coverage is issued the facility is covered by the General Permit. That is, the permittee is authorized to discharge stormwater, process wastewater, and/or mine dewatering pursuant to the type of General Permit until the permit expires or is modified or revoked. • Any other point -source discharge to surface waters of the state is prohibited unless it is an allowable non-stormwater discharge or is covered by another permit, authorization, or approval. • There are currently 19 active general permits. Permit conditions vary accordingly-, however, most of the permits have the following condition requirements (you must read your entire permit to ensure full compliance): o Development and compliance with the Stormwater Pollution Prevention Plan o Collection, reporting, and recording of Analytical Monitoring Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresviile, NC 28115 One t Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service: 1-877-623-6748 NOrthCarofina Entemet:www.ncwaterquality.org - rn `r� An Equal Opportunity 1 A`firmative Acton Employer - 30% RecycleVO% Past Consumer paper A�tuL yi`1 Scott Clark, Dixon Quick Coupling Stormwater Sampling, Page 3 April 6. 2010 o Collection, reporting, and recording of Qualitative Monitoring o Collection, reporting, and recording of Vehicle Maintenance Monitoring (if applicable) o Records — Visual monitoring shall be documented and records maintained at the facility along with the Stormwater Pollution Prevention Plan. Copies of the analytical monitoring results shall also be maintained on site. The Permittee shall retain records of all monitoring information, including all calibration and maintenance records and all original strip -chart recordings for continuous monitoring instrumentation, and copies of all reports required by this general permit for a period of at least 5 years from the date of the sample measurement, report, or application. o Expiration — The permittee is not authorized to discharge after the expiration date of the general permit. In order to receive automatic authorization to discharge beyond the expiration date, the permittee shall submit forms and fees as are required by the agency authorized to issue permits no later than 180-days prior to the expiration date. Any permittee that has not requested renewal at least 180 days prior to expiration, or any permittee that does not have a permit after the expiration and has not requested renewal at least 180 days prior to expiration, will be subject to enforcement. Failure to renew your permit is a violation. o Transfer — The Certificate of Coverage (COC) issued pursuant to this general permit is not transferable to any person expect after notice to and approval•by the Director. The Director may require modification or revocation and reissuance of the Certificate of Coverage to change the name and incorporate such other requirements as may be necessary under the Clean Water Act. The Permit is NOT transferable. o Name Change, Closure, or Facility Ownership change — Permittee is required to notify the Division in writing in the event the permitted facility is sold or closed. The Division of Water Quality views changes of name or ownership as a modification that requires the Director's approval and reissuance of the permit. Name and ownership changes require you to complete a Name/Ownership Change Form from the Division and mail it back to the Division of Water Quality along with all appropriate information. o Proper Operation and Maintenance is a requirement of the permit. Mooresville Regional office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663.60401 Customer Service:1-877-623-6748 Internet www.neNaterquality.org ne Noc6dhCarohna Naturally An Equal opportunity 1 Affirmative Action Employer - 30% Recycled110% Post Consumer paper ANALYTICAL RESULTS SHEET Name of Facility: Dixon Quick Coupling Grab: ® Composite: ❑ Sample Date(s): November 10, 2009 NPDES Permit No.: NCG030283 Sample Location: Outfall SDO #001 County: Mecklenburg Temperature 17.04 °C Fecal coliform (CFU/100 mL) <100/100 mL Dissolved Oxygen 9.48 mg/L E. Coli (MPN1100 mL) <100/100 mL Conductivity 41 µS/cm Enterococcus (MPN/100 mL) 7,2001100 mL pH 9.04 SU Ammonia -nitrogen (NH3-N) 0.13 mg1L Turbidity 7.1 NTU Total Kjeldahl Nitrogen (TKN) 0.28 mg/L Biological Oxygen Demand, 5-day (BODO 5.9 mg/L Nitrate/Nitrite-nitrogen (NO2 and NO3) 0.32 mg/L Chemical Oxygen Demand (COD) 49 mg/L Total Phosphorus (P) 0.069 mg1L Total Suspended Solids (TSS) 19 mg/L Chromium (Cr) 6.4 µg/L Total Sediment Concentration 18 mg/L Copper (Cu) 170 µg/L Oil & Grease <5.0 mg/L Lead (Pb) 61 µg/L* Total Toxic Organics (TTO) "* Zinc (Zn) 290 µg/L Denotes an exceedance of the permit benchmark values "" Did not sample for this parameter Allocco, Marcia From: Terry Carter [terry@dixonquickcoupling.com] Sent: Sunday, February 28, 2010 12:18 PM To: Allocco, Marcia; Eubanks, Ron Cc: Crystal Mccabe; Scott Clark Good Morning, The results of Lead Testing previously discussed are listed below. Sample 1A - 9.9 uglL 1.0099 mglL Sample iB - 114 ug1L / .114 mglL Taken from behind the building where the 2 drains meet and drain out the front of the loading dock. Sample 2 - 50.6 uglL 1 .0506 mglL Taken from the front of the loading dock. Sample 3 — 294 uglL 1 .294 mglL The isolated sample taken from Sample Location 2 where normal storm water samples are gathered. My plan is to take set of samples from the alley where brass is stored. They are calling for rain on Tuesday. I will send those results as soon as they are available. In the interim, if you can think of further testing that might help us please do not hesitate to contact me. Thank You, Terry Carter Dixon Quick Coupling Ph: 704-405-3523