Loading...
HomeMy WebLinkAboutWQ0024427_Variance Request_20190912 v , ROY COOPER iii,1 ''ate�1 Governor 6 �. 6?' MICHAEL S.REGAN Main- Secretary LINDA CULPEPPER NORTH CAROLINA Director Environmental Quality September 12, 2019 Mark Maynard, Manager Windsor Place Apartments, LLC 10 S. Cardinal Drive Wilmington, NC 28403 Subject: Variance Request Approval - Windsor Place Apartments Gravity Sewer Outfall Windsor Place Apartments, LLC New Hanover County Dear Mr. Maynard: The Division of Water Resources (Division) has reviewed the submitted variance request received on February 15, 2019 for the subject project, with additional information received June 23, 2019 and July 24, 2019. The Division will grant the variance requests for the installation of gravity sewer as well as manholes being located near wetland area in accordance with the provisions for alternative design under 15A NCAC 02T.0105(n): 1. Pursuant to the variance request received February 15,2019 with additional information received June 23, 2019 and July 24, 2019,from James H. Fentress,Jr., P.E. on behalf of the Windsor Place Apartments, LLC, a variance is granted for the construction and operation of approximately 65 linear feet of 8-inch gravity sewer located within wetlands,as indicated on the provided plans and supplementary documentation. 2. An alternative design is also approved for the construction of manholes MH-3 and MH-4, located immediately beside the wetlands areas as shown on the provided plans, and subject to the following requirements: a. Manholes shall be provided with a watertight frame and cover with gasket. b. Watertight pipe connections shall be provided consisting of a flexible watertight rubber boot or compression type connector. c. Structures shall be tested in accordance with ASTM C1244. d. All structures not included as part of a USACOE 404 Permit or Division 401 Certification shall maintain a separation of no less than 10 feet from wetlands. Regardless of the variance approval, in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions,the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. D A Nonmomnt Quality I Water Re 512 NorthrthCaroli SalisburyaDepart Street ent 11617ofEnvir Mail n Serviceeal Center I RaleighDivision,Northof Carolinasources 27699-1617 NORTH CAROLINA "°p"tenent IN B=0=1011191 tty 919.707.9000 Windsor Place Apartments, LLC September 12,2019 All other elements of this project shall be constructed in accordance with all applicable rules and statues including, 15A NCAC 2T; the Division of Water Resources', (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable;and the Division's Minimum Design Criteria for the Fast- Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable. Approval of the variance request does not constitute approval of the permit. If you have any questions, please contact Christyn Fertenbaugh at 919-707-3625 or via email at christyn.fertenbaugh@ncdenr.gov. Sincerely, ally for Linda Culpepper Director, Division of Water Resources by Christyn Fertenbaugh, P.E. PERCS Unit, Division of Water Resources, NCDEQ cc: James H. Fentress,Jr., P.E.,Stroud Engineering, PA(jentress@stroudengineer.com) Wilmington Regional Office,Water Quality Section (electronic copy) PERCS Files (electronic copy)