Loading...
HomeMy WebLinkAboutNCG551416_NOV-2019-PC-0613 Response_20190913XV DePte'rtnvlr ohnl egra l Qua li [Y sip Reg ...a! Oft"c e Septic System installation & Maintenance 1-888-817-1904 Ref: Bay Leaf Fire Dept. NOV2019-PC-0613 /XG 55 H/h After the initial site visit with Cory Larsen. I scheduled a re -sampling of the effluent. To address the PH, I added 4 Ibs of baking soda. Latest lab data attached shows PH at 5.7. 1 spoke to the treatment system manufacturer and to Cory Larsen. We agreed on a plan to change recirculation rates and add additional baking soda until PH is in compliance. I will re -sample in a few days. To address the fecal, I pulled and UV sleeve to examine, it had been previously cleaned in April, it did not appear dirty, but was cleaned. Also I changed to protocol during sampling so as not to create velocity in the discharge piping. Latest lab data shows fecal as ND. I believe the protocol was more responsible for this change in lab results than the cleaning. Cory J. Brantley David Brantley and Sons INC aceAnalytica( www.pecekDscme i I ANALYTICAL RESULTS Project: Bay Leaf Fire Dept Pace Project No.: 92443780 Pace Analytical Services, LLC 6701 Conference Drive Raleigh, NC 27607 (919)834.4984 Sample: EFF Lab ID: 92443780001 Collected: 09/03/19 08:30 Received: 09/03/19 09,00 Matrix- Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Clual 4500H+ pH, Electrometric EDN Analytical Method: SM 4500-H+B-2011 PH at 25 Degrees C 5.7 Std. Units 1.0 1 09/04/19 16:10 H3 Colllert-18 Fecal Coliform RAL Analytical Method: Colliert-18 Preparation Method: Colilert-18 Fecal Coliforms ND MPN1100mL 1.0 1 09/03/19 15:54 091041 19 12:44 Date: 09/06/2019 12:46 PM XC Dept of Environmental Quality SEP 13 2019 Meigh Regional Off;icc REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 4 of 9 R S ~ Z;Rt N E B a �u�i Eli , 'u1 N lwi r..... — . 9