Loading...
HomeMy WebLinkAboutNC0056154_More Information (Received)_20190903Aqua North Carolina, Inc. 4163 Sinclair Street Denver, NC 28037 September 3, 2019 Mr. W. Corey Basinger Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Re: Bridgeport WWTP, Iredell County Compliance Evaluation Inspection Report NPDES Permit No. NC0056154 Dear Mr. Basinger: Aqua North Carolina, Inc. (Aqua) offers the following response to the items outlined in the above - referenced Compliance Evaluation Inspection Report which was issued for the inspection conducted on August 1, 2019: Flow Measurement Effluent Section . It is requested that a written response be submitted addressing the concerns regarding the location of the head measuring device for the flow measurement system. The flow meter was last calibrated/verified by the ORC on February 4, 2019. The V-notch weir was replaced following the previous inspection, however; the head measuring device location (distance upstream of the V- notch weir) still appears to be less than three times the maximum expected head on the weir (Reference: ISCO Open Channel Flow Measurement Handbook). This office requests that a third - party verification be performed to determine whether or not the head measuring device is in the proper location. Agua's Response: The location of the transducer was not changed when it was replaced. However, Aqua contacted a third party to verify the distance and calibration of the flow meter and its components. A copy of that calibration report is attached. Prior to Horizon Engineering's visit, the ORC had relocated the transducer to a location acceptable to the inspector. If you have any questions, please do not hesitate to contact me at 704-489-9404. Sincerely, Laurie Ison Area Manager Aqua North Carolina, Inc. An Aqua America Company Mt. Pleasant, N.C. 281 Flaw Meter Calibration Data Sheet Facility I arrle, . �rid� uertt a�tawav fibre t bdivi len_ city: -Momunt mou.ma Stfe N. . Utility Name. Floater Utilities Inc. Primary Crevice weir, etc.): 90 deg - notch el�`r Flow Meter Hard,. ICJ Model: 4210 Serial No.197Ft1274 Type: Bubbler X Ultrasonic Other' lPrimary Device:Comments: Level yes no Free Flaw yes no C. Turbulence yes no D. Blockage yes no E, Surface' Buildup yes no F. Properly Mounted n yes no II. liter Programmed correct - `yes_ no B, Calibration I. Calibrated with flew cut off yes no If yes; Level Before Level After Resume flog, compare measured level to meter reading. Ved y that readings agree yes >__no If no, Flow Level Before Flaw Level After C`, Check if level to flow conversion for primary device is correct: yes no , heck to see'if flow is totalized correctly; des no Calibrated by Date. * a J arrre, Time: r u