Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0000484_Site Plans/Maps_20190911
8 1 7 1 6 1 5 4 3 2 1 It H G 12, E ❑@ C 191 A I SITE LOCATION MAP SCALE: 1 "=1 ,000' REFERENCE: U.S.G.S. 7.5' TOPOGRAPHIC MAP, PARKTON, NC AND RENNERT, NC. DATED 2016 NORTH VItrII111 T IVIHh' SCALE: 1 "=1000' REFERENCE: IMAGE COURTESY OF GOOGLE EARTH PRO. DATED REVISION RECORD NO DATE DESCRIPTION 04/01/2019 ISSUED FOR CONSTRUCTION A, 08/08/2019 AS -BUILT 7 6 NORTH MOUNTAIR FARMS, INC. LUMBER BRIDGE TOWNSHIP, NORTH CAROLINA APRIL 2018 97:7_\TITI10Eta 10197�:1 0 COVER SHEET 001 GENERAL NOTES 002 PROCESS & INSTRUMENTATION LEGEND SHEET 010 PROCESS FLOW DIAGRAM 011 PROCESS & INSTRUMENTATION DIAGRAM 012 PROCESS & INSTRUMENTATION DIAGRAM 013 PROCESS & INSTRUMENTATION DIAGRAM 014 PROCESS & INSTRUMENTATION DIAGRAM 015 PROCESS & INSTRUMENTATION DIAGRAM 016 PROCESS & INSTRUMENTATION DIAGRAM 017 PROCESS & INSTRUMENTATION DIAGRAM 040 HYDRAULIC PROFILE 041 HYDRAULIC PROFILE 100 EXISTING SITE PLAN 101 PROPOSED SITE LAYOUT PLAN 102 PROPOSED SITE LAYOUT PLAN — MBBR TANKS 103 PROPOSED SITE LAYOUT PLAN — ABOVEGROUND CLARIFIER 104 PROPOSED SITE LAYOUT PLAN — FEED FORWARD PUMP STATION AREA 105 PROPOSED SITE LAYOUT PLAN — FRAC TANK AREA 111 EROSION AND SEDIMENT CONTROL PLAN 112 EROSION AND SEDIMENT CONTROL PLAN DETAILS 130 EFFLUENT PIPE PLAN AND PROFILE — STA 0+00 TO 4+00 131 EFFLUENT PIPE PLAN AND PROFILE — STA 4+00 TO 9+00 132 EFFLUENT PIPE PLAN AND PROFILE — STA 9+00 TO 12+10 200 EXISTING BUILDING CONDITIONS 201 TREATMENT BUILDING PROCESS MODIFICATIONS, DEMOLITION PLAN 202 FEED FORWARD PUMPING STATION PROCESS MODIFICATIONS DEMOLITION PLAN & SECTIONS 230 TREATMENT BUILDING PROCESS MODIFICATIONS, EQUIPMENT LAYOUT 231 TREATMENT BUILDING PROCESS MODIFICATIONS SECTIONS 232 PROPOSED MBBR TANK LAYOUT SECTIONS 271 MBBR TANK No. 1 PLANS AND ELEVATIONS 272 MBBR TANK No. 2 PLANS AND ELEVATIONS 280 MISCELLANEOUS DETAILS 281 PIPE SUPPORT DETAILS 282 ELEVATED PIPE SUPPORT DETAILS 283 DAF SUPPORT DETAILS 284 STRUCTURAL MBBR STAIRS PLANS AND SECTIONS 285 STRUCTURAL MBBR STAIRS MISCELLANEOUS DETAILS 500 ELECTRICAL SITE PLAN 501 PROPOSED SINGLE LINE DIAGRAM 502 PROPOSED BLOWER BUILDING ELECTRICAL PLAN, SCHEDULES AND DETAILS 503 PROPOSED ELECTRICAL SITE PLAN AS BUILT DRAWING NO.: H G F E C 13 FRAZER, PENNSYLVANIAAW / MOUNTAIRE FARMS INC COVER SHEET (610) 407-4100 NC Firm License # C-3035 WASTEWATER TREATMENT KEG I . NET Civil & Environmental Consultants, Inc. SYSTEM UPGRADE 000 Keystone DATE: APRIL 2018 DRAWN BY: JKS A #C-4160 LICENSE 1900 Center Park Drive - suite A -Charlotte, NC 28217 LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: NTS I CHECKED BY: GPT/MDW ENGINEERING G R O U P Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: 174-540 www.cecinc.com APPROVED BY: GPTI SHEET OF 6 5 4 3 2 1 7 H GENERAL NOTES 7 0 5 4 3 2 1 H a 41 1. CONTRACTOR TO SUBMIT SHOP DRAWINGS ON ALL MAJOR EQUIPMENT PURCHASED, ALL FABRICATED STEEL ITEMS AND ALL ELECTRICAL ITEMS. 2. ALL SUBSTITUTIONS TO BE APPROVED BY ENGINEER PRIOR TO PURCHASE AND INSTALLATION. 3. ALL NEW CONSTRUCTION FERROUS METALS TO BE PAINTED PRIOR TO COMPLETION OF JOB. SURFACE PREPARATION, CLEANING, AND COATING TO BE IN STRICT ACCORDANCE WITH COATING MANUFACTURER'S RECOMMENDATIONS. COATINGS TO BE AS FOLLOWS OR ENGINEER -APPROVED EQUAL: 3.A. FABRICATED FERROUS METALS AT 6 IN AND ABOVE SUBMERGED AREAS: SURFACE PREPARATION: SSPC-SP6 COMMERCIAL BLAST; FIRST COAT TNEMIC SERIES 61-5002 BEIGE PRIMER, 8-12 MILS DFT; FINISH COAT TNEMIC SERIES 61-5001 GRAY FINISH, 8-12 MILS DFT 3. B. FABRICATED FERROUS METALS IN SUBMERGED AREAS AND TO 6 IN ABOVE: SURFACE PREPARATION: SSPC-SP10 NEAR WHITE BLAST; FIRST COAT TNEMIC SERIES 61-5002 BEIGE PRIMER, 8-12 MILS G DFT; FINISH COAT TNEMIC SERIES 61-5001 GRAY FINISH, 8-12 MILS DFT 3.C. PIPE SUPPORTS: SURFACE PREPARATION: SSPC-SP3 POWER TOOL CLEANING; FIRST COAT TNEMIC SERIES 135 CHEMBUILD, 4-6 MILS DFT; SECOND COAT TNEMIC SERIES 66 HI -BUILD EXPDXOLINE PRIMER, 4-6 MILS DFT; FINISH COAT TNEMIC SERIES 73 ENDURA-SHIELD, 2-3 MILS DFT 01 4. TANK ERECTION TO BE IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. REPAIR SHALL BE DONE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 5. CONTRACTOR TO CONDUCT LEAKAGE TESTS ON ALL WATERTIGHT STRUCTURES AND PIPELINES. CONTRACTOR TO NOTIFY OWNER WHEN WORK IS READY FOR TESTING UNDER DIRECTION OF OWNER OR ENGINEER. ALL LABOR, EQUIPMENT AND MATERIALS, INCLUDING METERS AND GAUGES SHALL BE FURNISHED BY CONTRACTOR AT HIS OWN EXPENSE. ANY STRUCTURE OR SECTION OF PIPE WHICH DOES NOT COMPLY WITH LEAKAGE TESTS, AS DETERMINED BY OWNER OR ENGINEER, SHALL BE PROMPTLY CORRECTED, REPLACED OR REPAIRED BY CONTRACTOR AT CONTRACTOR'S EXPENSE. METHODS EMPLOYED FOR CORRECTION SHALL BE APPROVED BY ENGINEER OR OWNER. LEAKAGE TESTS TO BE CONDUCTED ACCORDING TO THE FOLLOWING TEST SCHEDULE: TYPE TEST MEDIA TEST CRITERIA STRUCTURES WATER HYDROSTATIC <1/2 INCH DROP IN 24 HOURS PRESSURE PIPING WATER PRESSURE 20 PSIG FOR 12 HRS. MAINTAIN MIN 95% OVER TEST PERIOD SEWER PIPE WATER HYDROSTATIC 6 FEET HEAD MAINTAINED 4 HRS AIR PRESSURE 5 MIN AT 5 PSI CONTAINMENT PIPE WATER HYDROSTATIC 6 FEET HEAD MAINTAINED 4 HRS CHEMICAL HOSE WATER PRESSURE 20 PSIG FOR 4 HRS. MAINTAINED MIN 95% E OVER TEST PERIOD 1. ABOVEGROUND PIPE TO BE PVC TYPE L, GRADE L WITH T102 ULTRAVIOLET LIGHT INHIBITOR AND SHALL BE SCH 80, CONFORMING TO ASTM D17848 AND D1785 AS APPLICABLE. FITTINGS SHALL BE APPLICABLE WITH PIPE TYPE AND SHALL CONFORM TO ASTM D2484, D2466, Z OR D2467 AS APPLICABLE. ALL PIPING SHALL BE SOCKET UNLESS OTHERWISE NOTED FOR INSTALLATION BY SOLVENT WELDING. n C 191 A I 2. BELOW GROUND PIPE TO BE PVC C900 CELL CLASS 12454 MIN. DR 51 (80 PSI), CONFORMING TO ASTM D-1784 AS APPLICABLE. PIPE TO MEET STANDARDS OF AWWA C900-16. INTEGRAL BELL TO MEET REQUIREMENTS OF ASTM D-3139 AND ELASTOMERIC SEAL MEETING ASTM F-477. GASKET MATERIAL TO BE EPDM OR ENGINEER APPROVED EQUAL. INSTALLATION TO BE IN COMPLIANCE WITH AWWA C605. 3. CPVC PIPE TO BE TYPE IV, GRADE I CONFORMING TO MINIMUM CELL CLASS OF 23447 PER ASTM D 1784 SCH 80, CONFORMING TO ASTM F441 /F441 M AS APPLICABLE. FITTINGS SHALL BE APPLICABLE WITH PIPE TYPE AND SHALL CONFORM TO ASTM F437 OR F439 AS APPLICABLE. ALL PIPING BE SOCKET UNLESS OTHERWISE NOTED FOR INSTALLATION BY SOLVENT WELDING. 4. STEEL PIPE SHALL CONFORM TO 0.375 IN WALL, SEAMLESS, BLACK CARBON STEEL, CONFORMING TO ASTM A53/A53 M, GRADE B, TYPE E. FITTINGS TO BE STEEL, BUTT WELDED TO MATCH PIPE WALL THICKNESS CONFORMING TO ASTM A234/A234 M AND ASME B.19. FIELD WELDED JOINTS SHALL CONFORM TO AWS-03 AND ASME B31.3. 5. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDER AND SHALL CONFORM TO AWS STANDARDS. 6. STAINLESS STEEL PIPE TO BE 304 L SCHEDULE 10S, ASTM A-240 STAINLESS STEEL CONFORMING TO ASTM A-778 FOR 3" AND LARGER. PIPE 2 1/2" AND SMALLER SHALL BE SCH. 40S, SEAMLESS ASTM A-240 TYPE 304 L STAINLESS STEEL CONFORMING TO ASTM A-312. FITTINGS SHALL BE 304 L SCHEDULE 10S, ASTM A-240 ST. STEEL BUTT WELDING FITTINGS CONFORMING TO ASTM A-774. FITTINGS 2 1/2" AND SMALLER SHALL BE SCHEDULE 40S, SEAMLESS, TYPE 304 L STAINLESS STEEL SCREWED FITTINGS CONFORMING TO ASTM 403 UNLESS OTHERWISE SPECIFIED. 7. ALL S.S. PIPE FLANGES ARE TO BE SLIP ON TYPE 150 LB. AMERICAN LIGHTWEIGHT BACKUP FLANGES CONFORMING TO A536-80, WITH SLIP-ON ANGLE RINGS. ALL PIPE FITTINGS AND JOINTS ARE TO BE RATED FOR MINIMUM 150 PSI WORKING PRESSURE, WITH ASTM A-307, GRADE B HEX NUTS. 8. S.S. WELDED JOINTS TO BE FREE FROM EMBEDDED SCALE OR SLAG, WITH TENSILE STRENGTH AT WELD NOT LESS THAN PIPE, USE BUTT WELDS FOR WELDED JOINTS IN FABRICATING FITTINGS, PERFORM WELDING IN ACCORDANCE WITH AWS D 7.0 AND ANSI B31.3 HAVE ELECTRODE FOR WELDING BY SMAW PROCESS AS SPECIFIED IN ASTM CODE SECTION 11, PARK C, SFAS5, 9, ELECTRODE CLASSIFICATION COMPATIBLE WITH STAINLESS STEEL TYPE. 9. ALL THREADED JOINTS TO CONFORM TO NPT STANDARDS, JOINTS TO BE SEALED WITH TEFLON TUBE OR THREAD SEALER. 10. ALL PIPE TO BE INSTALLED ABOVE GRADE TO BE SUPPORTED. PIPE SUPPORTS TO BE GRINNELL FIG 259 PIPE STANCHIN SADDLE OR ENGINEER APPROVED EQUAL. MINIMUM PVC SUPPORT SPACING AT 5 FT INTERVALS UNLESS OTHERWISE SPECIFIED. SUPPORT SPACING AT 23 FT UNLESS OTHERWISE SPECIFIED. 11. ALL AERATION PIPING TO BE INSULATED AND JACKETED. 12. ALL VALVES TO BE DEZURIK SERIES L KNIFE GATE, OR ENGINEER -APPROVED EQUAL UNLESS OTHERWISE SPECIFIED. USE INSULATING FLANGES AND WASHERS IF CAST IRON VALVES ARE USED WITH S.S. PIPE. SEAT MATERIALS SHALL BE 304 SS. ALL VALVES LARGER THAN 12" SHALL BE GEARED. 13. CONTRACTOR TO BE RESPONSIBLE FOR PROTECTION OF EXISTING UTILITIES. 14. CONTRACTOR TO CONFIRM EXISTING SEWER DEPTH IN FIELD. REVIEW MEASURED DEPTH WITH ENGINEER TO ALLOW FOR DESIGN P -/d/&)?? REVISION RECORD NO DATE DESCRIPTION 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION /3V 08/08/2019 AS -BUILT 7 MODIFICATION IF NECESSARY. 15. COORDINATE ALL ELECTRICAL, PIPING AND INSTRUCTION TIE-INS WITH OWNER. EXISTING TREATMENT PLANT TO REMAIN IN OPERATION DURING CONSTRUCTION. 16. PLUG VALVES WHERE SPECIFIED TO BE DEZURIK ECCENTRIC PLUG VALVE, CAST IRON BODY, NBR PACKING FLANGED ASME CLASS 150, LEVER ACTUATED. 17. BUTTERFLY VALVES WHERE SPECIFIED TO BE DEZURIK BUS RESILIENT SEATED BUTTERFLY VALVE, WAFER TYPE, DI BODY, NBR SEAT AND SEAL, 316 SS SHAFT AND DISC. 18. CHECK VALVES TO BE RITE PRO CHECK RITE SS WAFER CHECK VALVES, EPDM SEAT OR ENGINEER APPROVED EQUAL. 19. REACTOR TANK SCREEN ASSEMBLES AND EFFLUENT MANIFOLD TO BE PROVIDED BY ENTEX. CONTRACTOR RESPONSIBLE FOR CONNECTING PIPING AND INSTALLATION. 20. WHERE SPECIFIED HDPE ABOVEGROUND PIPE TO BE HDPE DR17 (125 psi), MATERIALS CONFORMING TO ASTM D3350 CELL CLASSIFICATION AS APPLICABLE. PIPE TO MEET REQUIREMENTS OF ASTM F714 AND AWWA C906-15. MOLDED FITTINGS SHALL BE MANUFACTURED AND TESTED INACCORDANCE WITH ASTM D 3261. FABRICATED FITTINGS SHALL BE IN ACCORDANCE WITH AWWA C906. 21. DISCHARGE PIPE TO BE COVERED WITH SOIL AND LOOSE TAMP EVERY 20 FEET TO MINIMZE THERMAL EXPANSION. 22. THRUST BLOCKS OR RESTRAINED JOINTS TO BE INSTALLED WHEN INDICATED. SEE DRAWING 280 FOR THRUST 23. INSTALL VACUUM BREAK PIPING WHERE INDICATED. MATCH PIPE MATERIALS. SEE DEATIL 1, SHEET 232. BURIED PIPE NOTES 1. THE MINIMUM ALLOWABLE TRENCH WIDTH SHALL NOT BE LESS THAN THE OUTSIDE DIAMETER OF THE PIPES PLUS EIGHT INCHES (8"), OR 14 INCHES FOR TWO PIPES. WHERE ROCK IS ENCOUNTERED, IT SHALL BE REMOVED TO A MINIMUM DEPTH OF FOUR INCHES (4") BELOW THE PIPE BELLS. 2. INSTALL PIPE, FITTINGS, AND ACCESSORIES IN ACCORDANCE WITH DRAWINGS. 3. WHENEVER POSSIBLE, SEWERS AND SEWER MANHOLES SHOULD BE LAID AT LEAST TEN FEET (10') HORIZONTALLY FROM ANY EXISTING OR PROPOSED WATER MAIN. SHOULD LOCAL CONDITIONS PREVENT A LATERAL SEPARATION OF TEN FEET (10'), A SEWER MAY BE LAID CLOSER THAN TEN FEET (10') TO THE WATER MAIN PROVIDED THAT THE BOTTOM (INVERT) OF THE WATER MAIN SHALL BE AT LEAST EIGHTEEN (18") ABOVE THE TOP (CROWN) OF THE SEWER, AND PROVIDED THAT THE WATER MAIN AND SEWER ARE INSTALLED IN SEPARATE TRENCHES. WHERE THIS VERTICAL SEPARATION CANNOT BE OBTAINED, THE SEWER SHALL BE CONSTRUCTED OF APPROVED WATER PIPE, PRESSURE TESTED, IN PLACE, WITHOUT LEAKAGE PRIOR TO BACKFILLING. 4. WHENEVER SEWERS MUST CROSS UNDER WATER MAINS, THE SEWER SHALL BE LAID AT SUCH AN ELEVATION THAT THE TOP OF THE SEWER IS AT LEAST EIGHTEEN INCHES (18") BELOW THE BOTTOM OF THE WATER MAIN. WHEN THE ELEVATION OF THE SEWER CANNOT BE BURIED TO MEET THE ABOVE REQUIREMENTS, THE WATER MAIN SHALL BE RELOCATED TO PROVIDE THIS SEPARATION OR THE SEWER LINE SHALL BE RECONSTRUCTED WITH DUCTILE IRON PIPE, OR PRESTRESSED CONCRETE CYLINDER PIPE FOR A DISTANCE OF TEN FEET ON EACH SIDE OF THE WATER LINE AND SHOULD BE PRESSURE TESTED, IN PLACE, WITHOUT LEAKAGE PRIOR TO BACKFILLING. ONE FULL LENGTH OF WATER MAIN AND SEWER MAIN SHOULD BE CENTERED OVER THE INTERSECTION SO THAT BOTH JOINTS WILL BE AS FAR FROM EACH OTHER AS POSSIBLE. 5. THE PIPE SHALL BE LAID ON A BED OF GRANULAR MATERIAL TO PROVIDE CONTINUOUS SUPPORT FOR THE LOWER SECTION OF THE PIPE. GRANULAR BEDDING SHALL BE #67 CRUSHED STONE. IN NO CASE SHALL THE SUPPORTING OF PIPE ON BLOCKS BE PERMITTED. 6. IN ALL CASES FROM THE BOTTOM OF THE TRENCH, TO A POINT SIX INCHES (6") ABOVE THE PIPE SHALL BE BACKFILLED WITH #67 CRUSHED STONE. 7. TRENCHES SHALL BE KEPT FREE OF WATER DURING THE LAYING OF PIPE AND UNTIL THE PIPELINE HAS BEEN BACKFILLED. 8. WITH ALL PIPING, THE CONTRACTOR SHALL INSTALL A TRACING TAPE WITH THE WORDS "BURIED PIPE BELOW". THE TAPE SHALL BE INSTALLED IN SAME TRENCH AND CENTERED ABOVE THE PIPE, AND AT APPROXIMATELY ONE (1) FOOT BELOW FINISHED GRADE. THE TAPE SHALL BE LINE GUARD TYPE II DETECTABLE, OR EQUAL. 9. WHEN LAYING OF PIPE IS STOPPED AT THE END OF THE DAY, THE EXPOSED END OF PIPE SHALL BE CLOSED WITH A PLUG FITTED INTO THE PIPE, SO AS TO EXCLUDE EARTH OR OTHER MATERIAL AND PRECAUTIONS TAKEN TO PREVENT FLOTATION OF PIPE BY RUNOFF OR GROUNDWATER MIGRATION INTO TRENCH. 10. ALL BACKFILLING SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE DETAILS SHOWN ON THE DRAWINGS AND AS DESCRIBED HEREIN. ANY VARIANCES MUST BE APPROVED IN WRITING BY THE OWNER AND ENGINEER. AS BUILT DRAWING NO.: G F E FBI C 13 JW MOUNTAIRE FARMS, INC GENERAL NOTES FRAZER, PENNSYLVANIA (610) 407-4100 NC Firm License # C-3035 WASTEWATER TREATMENT KEGI.NET Civil & Environmental Consultants, Inc. 001 SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS A Kv-etone NC FIRM LICENSE 1900 Center Park Drive - suite A -Charlotte, NC 28217 LUMBER BRIDGE NORTH CAROLINA DWG SCALE: NTS CHECKED BY: GPT/MDW ENGINEERING G R O U P Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: 174-540 www.cecinc.com APPROVED BY: GPT SHEET OF 6 5 4 3 2 1 a 8 1 PIPING COMPONENT IDENTIFIERS ACK ALARM CHECK VALVE AG GLOBE (ANGLE PATTERN) H AR AIR RELIEF VALVE BCK BALL CHECK VALVE BFP BACKFLOW PREVENTER VALVE BF BUTTERFLY VALVE BA BALL VALVE BS BLIND SPACER BD BLOWDOWN VALVE CA ANGLE CHECK VALVE CD DUAL PLATE CHECK VALVE CK CHECK VALVE CL CHECK LIFT VALVE CS SWING CHECK VALVE CT TILTING DISK CID DIAPHRAGM CHECK VALVE DP DIAPHRAGM DV DELUGE VALVE EXJ EXPANSION JOINT EWS EYE WASH STATION G FB FLUSH BOTTOM FH FIRE HOSE FHC FIRE HOSE CABINET FLT FILTER FXH FLEXIBLE HOSE GA GATE VALVE GLK GREYLOCK FITTING GL GLOBE VALVE HYD HYDRANT ISD ISOLATION DAMPER ISV ISOLATION VALVE KG KNIFE GATE VALVE NC NORMALLY CLOSED ND NEEDLE VALVE NO NORMALLY OPEN OS OPEN SPACER OR ORIFICE DRAIN F PC PINCH/CLAMP PL PLUG VALVE PR PRESSURE RELIEF VALVE QCON QUICK DISCONNECT RV RELIEF VALVE RT ROOT VALVE Sc STOP CHECK VALVE SCN SCREEN SHR SHOWER SH SHUTDOWN VALVE SIL SILENCER SLG SLUICE OR SLIDE GATE SLV2 2-WAY SOLENOID VALVE SLV3 3-WAY SOLENOID VALVE SLV4 4-WAY SOLENOID VALVE SP SPECIAL SPGR SPARGER STIR STRAINER E TRP TRAP VAR VACUUM BREAKER WITH AIR RELEASE VALVE VTV VENT VALVE YG GLOBE (T-PATTERN) YSTR Y-STRAINER 7 1 VALVE AND ACCESSORIES SYMBOLS S 3-WAY VALVE 2-WAY SOLENOID 4-WAY PLUG VALVE 51 3-WAY SOLENOID AIR RELEASE/ADDITION 4-WAY SOLENOID ANGLE BLOWDOWN 6 1 5 PIPING SYMBOLS & ACCESSORIES D�hD4 BACK PRESSURE REGULATOR ANGLE VALVE CYLINDER OPEN/CLOSE BACK FLOW PREVENTER BALL VALVE 43 CYLINDER THROTTLING BALL CHECK VALVE * I BUTTERFLY VALVE DIAPHRAGM OPEN/CLOSE DIAPHRAGM VALVE DIAPHRAGM THROTTLING CHEMICAL INJECTION /CHECK VALVE ELECTRIC OPEN/CLOSE FOOT VALVE (POLYMER FEEDERS) M 4f 5f FOUR OR FIVE FUNCTION VALVE ELECTRIC THROTTLING (CHEMICAL METERING PUMP) GATE VALVE HAND CONTROL GLOBE VALVE PILOT LINE KNIFE GATE VALVE PRESSURE REGULATOR NEEDLE VALVE (SELF CONTAINED) PINCH VALVE PRESSURE REGULATOR WITH REMOTE PLUG VALVE SWING CHECK VALVE PRESSURE/VACUUM RELIEF VALVE (PSV) PRES VAC TO ATMOSPHERE WAFER CHECK PROCESS EQUIPMENT SYMBOLS U FLOAT ULTRASONIC CHEMICAL TRENCH DRAIN SWITCH SENSOR TOTE WITH D CONTAINMENT 1 0■ L7 ■ 0■ Y T DRAIN TO FLOOR DRAIN TOP ENTRY SIDE ENTRY BUCKET MIXER MIXER vwtnr 1 J CENTRIFUGAL PROGRESSING CENTRIFUGAL DIAPHRAGM SUMP PUMP CAVITY PUMP PUMP PUMP o O ID O f CHEMICAL CENTRIFUGAL ROTARY BASKET METERING BLOWER COMPRESSOR STRAINER PUMP E= flm STATIC HEAT SCREW CONVEYOR MIXER EXCHANGER CONVEYOR DOME TOP TANK FLAT TOP TANK 8 OPEN TOP TANK EQUIPMENT & COMPONENT NUMBERING CONVENTION T - 1201 SEQUENTIAL NUMBER COMPONENT IDENTIFIER EQUIPMENT EQUIPMENT WILL BE PURCHASED BY TAG NUMBER AND WILL NOT REQUIRE A MATERIAL ID. PIPING PIPING VALVES AND MISCELLANEOUS PIPING COMPONENTS COMPONENTS SUCH AS TRAPS AND STRAINERS WILL BE PURCHASED BY MATERIAL ID. THIS MATERIAL ID WILL BE SHOWN DIRECTLY BELOW THE TAG NUMBER. VALVE IDENTIFICATION V-5112 VALVE TYPE VALVE ID NUMBER EQUIPMENT NUMBERS ® BREATHER CONCENTRIC REDUCER COUPLING ® DIAPHRAGM SEAL DETONATION ARRESTOR ECCENTRIC REDUCER EJECTOR OR EDUCTOR EXPANSION JOINT ELECTRO-PNEUMATIC P CONVERTER (CURRENT TO PRESSURE) FEMALE HOSE CONNECTOR FLAME ARRESTOR FLANGE CONNECTION FLEXIBLE COUPLING FLUSH CONN. w/ QUICK COUPLING �S IN -LINE SILENCER LG LEVEL SIGHT GLASS 1 D--►���Q MAGMETER FLOWMETER WITH REDUCERS 5D 3D 4 NSTRUMENTATION SYMBOLS OX LOCALLY MOUNTED MALE HOSE CONNECTOR INSTRUMENT (X = FUNCTION, IF NEEDED) ORIFICE PLATE MAIN PANEL MOUNTED INSTRUMENT PIPING -TO -TUBING OR HOSE w/QUICK COUPLING BACK OF MAIN PANEL MOUNTED INSTRUMENT PULSATION DAMPENER e MOTOR CONTROL CENTER MOUNTED INSTRUMENT FI ROTOMETER W/ RATE SET COMPUTER INTERFACED INSTRUMENT SAFETY SHOWER/ H/HH COMPUTER DISPLAYED EYE WASH L/LL ALARMS INSTRUMENTS SHARING SIGHT FLOW INDICATOR COMMON HOUSING Co (i.e. INTEGRAL XMTR) SPRAY NOZZLE PILOT LIGHT (X = LENS COLOR) ❑T STEAM TRAP RELAY LOGIC OI INTERLOCK IN PANEL 3 INSTRUMENT IDENTIFICATION FIRST LETTER PROCESS VARIABLE SECOND LETTER MODIFIER SUCCEEDING LETTERS A ANALYSIS ALARM ALARM B BURNER BATCH C CONTROL CONTROL CONTROL D DENSITY DIFFERENTIAL DRIVE E VOLTAGE ELEMENT ELEMENT F FLOW RATIO G GAUGING (DIM) GAUGE/GLASS H HAND HIGH I CURRENT INDICATE INDICATE J POWER SCAN K TIME L LEVEL LOW/LIGHT 0 OPERATING ORIFICE P PRESSURE POINT Q QUANTITY TOTALIZE R RADIATION RECORD/PRINT S SPEED SAFETY/SWITCH SWITCH T TEMPERATURE TRANSMIT TRANSMIT U MULTI —VARIABLE MULTI —FUNCTION MULTI —FUNCTION V VIBRATION VISCOSITY VALVE W WEIGHT (FORCE) WELL X ISOLATION VIDEO RELAY/COMPUTE Y TORQUE Z POSITION ACTUATE ® THERMAL SHUT OFF VALVE R MOTOR CONTROL �THRU WALL OR FLOOR INSTRUMENTATION INSTALLATION NOTES: UNION 1. PIPING ARRANGEMENTS SHOWN ARE SCHEMATIC. INSTRUMENT LOCATIONS ARE APPROXIMATE. THEY MAY BE MOUNTED ON ADJACENT COLUMNS, WALLS OR STRUCTURE. CAUTION SHOULD BE USED TO AVOID STRUCTURAL MEMBERS THAT ARE SUBJECT TO VIBRATION. 2. ALL FIELD INSTRUMENTS NOT INTEGRAL WITH PROCESS PIPING ARE TO BE LOCATED 4'-6" FROM FLOOR OR PLATFORM UNLESS OTHERWISE NOTED. US VENT SILENCER 3. PROCESS CONNECTIONS TO FIELD MOUNTED EQUIPMENT ARE TO BE SLOPED A MINIMUM OF 1/4" PER FOOT. SLOPE TOWARD PROCESS CONNECTION FOR GASES, AWAY FROM PROCESS CONNECTIONS FOR STEAM AND LIQUID APPLICATIONS. LOW POINT DRAINS AND HIGH POINT c WELD-O-LET n THRD-O-LET OR SADDLE Y-STRAINER LINE NUMBERING CONVENTION 4"-C900 PVC-DR-001 MATERIAL ALM ALUMINUM PIPE BPT BRAIDED PLASTIC TUBING CIP CAST IRON PIPE CIS CAST IRON SOIL PIPE CM CHROME/MOLY CMH CHEMICAL HOSE CN CONCRETE CPVC CHLORINATED POLYVINYL CHLORIDE PIPE CMC CORRUGATED METAL CULVERT PIPE CMP CORRUGATED METAL PIPE CS CARBON STEEL CU COPPER DI DUCTILE IRON FRP FIBERGLASS REINFORCED PLASTIC PIPE GS GALVANIZED STEEL KLS KYNAR LINED STEEL PIPE NI NICKEL NEO NEOPRENE HOSE NLS NEOPRENE LINED STEEL PIPE FIRST NUMBER — PROCESS SECOND NUMBER — DEVICE 1 — RAW WASTEWATER 1 — VALVES 2 — PRIMARY SETTLING 2 — TANKS 3 — PUMPING STATION 3 — INSTRUMENTATION 4 — PLANT REUSE 4 — MOTOR 5 — BIOLOGICAL TREATMENT 6 — SECONDARY SETTLING 7 — SLUDGE (WAS) HANDLING PE PEP PLS POP PVC RUB RCC RCP RHS SS TEF TLS TYB TYG VENTS WILL BE PROVIDED AS SHOWN ON THE INSTRUMENT DRAWINGS. 4. ALL TUBING SHALL BE INSTALLED AS TO PRESERVE MAXIMUM CLEARANCE AND HEADROOM. ROUTING SHOULD NOT INTERFERE WITH PLANT MAINTENANCE AND OPERATIONS. 5. UNSUPPORTED AND/OR UNPROTECTED INDIVIDUAL TUBING RUNS WILL BE IN 1 1 /2" x 1 1 /2" x 1 /8" CHANNEL. CONTRACTOR TO FIELD ROUTE AND SUPPORT CHANNEL AS NECESSARY. 6. INSTRUMENT SIGNAL WIRING SHALL NOT BE RUN IN THE SAME CONDUIT AS POWER WIRING. 7. SPLICING OF INSTRUMENT SIGNAL WIRES WILL NOT BE ALLOWED. 8. SHIELDING FOR INSTRUMENT SIGNAL WIRES ARE TO BE GROUNDED AT THE CONTROL PANEL ONLY. TAG NUMBER REFERENCE EQUIPMENT COMPONENT IDENTIFIERS ABS ABSORBER CLDR CYLINDER MEL MIST ELIMINATOR XX ACT ACTIVATOR DMP DAMPER MIX MIXER ACC ACCUMULATOR DEA DEAERATOR OGN OIL GUN 4250 AER AERATOR DCB DECARBONATOR POND POND AGT AGITATOR DHU DEHUMIDIFIER PCP PRECIPITATOR AV ACTUATED VALVE DIN DEMINERALIZER PRS SLUDGE FILTER PRESS AHU AIR HANDLING UNIT DSH DESUPERHEATER PVR PULVERIZER UNIQUE NUMBER SEQUENCE ACU AIR CONDITIONING DRUM DRUM P PUMP SEQUENTIAL NUMBER PACKAGE UNIT DRY DRYER PFR PURIFIER EQUIPMENT TYPE ID NUMBER PIPE LINE GROUP SERVICE AL AIR LOCK DCOL DUST COLLECTOR RCV RECEIVER PROCESS ID NUMBER ASLD AIR SLIDE ECON ECONOMIZER RGTR REGENERATOR PIPE MATERIAL ANN ANNUNCIATOR EDR EDUCATOR RH REHEATER NOMINAL SIZE OF PIPE ATZ ATOMIZER ENG ENGINE RPD RUPTURE DISK PROCESS ID NUMBER ATM ATTEMPERATOR EJR EJECTOR SAMPLER SAMPLER 1 - INFLUENT WASTEWATER BSN BASIN EC ELECTROLYTIC CELL SPNL SAMPLE PANEL PUMPING STATION BIN BIN EVAP EVAPORATOR SCN SCREEN 2 - PRIMARY SETTLING BS BLIND SPACER EXC EXCITER SEP SEPARATOR BLO BLOWER FAN FAN SILO SILO 3 - PUMPING STATION 4 - PLANT REUSE BLR CHU BOILER CHILLER UNIT FAR FCL FLAME ARRESTOR FLUID COUPLING SLR SKID SLAKER SKID 5 - BIOLOGICAL TREATMENT CHL CHLORINATOR FDR FEEDER SKR SKIMMER HDPE DR11 (4710) CLF CLARIFIER FLT FILTER SBLO SOOT BLOWER POLYETHYLENE PIPE 6 - SECONDARY SETTLING CLW CLEARWELL GEN GENERATOR STK STACK POLYPROPYLENE LINED STEEL 7 - SLUDGE/WAS HANDLING CL COIL GSC GLAND STEAM CONDENSER STKR STACKER PIPE POLYPROPYLENE PIPE COL COLLECTOR HTR HEATER STR STRAINER POLYVINYL CHLORIDE PIPE CMP COMPRESSOR HX HEAT EXCHANGER STRC STACKER/RECLAIMER RUBBER HOSE EQUIPMENT TYPE ID NUMBER COND CONDITIONER HCL HEATING COIL SJAE STEAM JET AIR EJECTOR REINFORCED CONCRETE 1 - VALVES CDU CONDENSING UNIT HST HOIST SUMP SUMP CULVERT PIPE REINFORCED CONCRETE PIPE 2 - TANKS CONR CONDITIONER HOOD HOOD SH SUPERHEATER REINFORCED HOSE 3 - INSTRUMENTATION CONT CONTAINMENT HPR HOPPER SF SUPPLY FAN STAINLESS STEEL PIPE STAINLESS CNVR CONVEYOR HUM HUMIDIFIER TK TANK TEFLON TUBING 4 - MOTORS TEFLON LINED STEEL PIPE CLR COOLER IGN IGNITOR TWR TOWER TYGON TUBING (BRAIDED) CTW COOLING TOWER IX ION EXCHANGER TRB TURBINE TYGON TUBING (UNBRAIDED) THIRD/FOURTH NUMBER CPN CORROSION COUPON LSL LINK SEAL TGR TURNING GEAR (SEQUENTIAL ORDERING, LEFT COUP COUPLING LVR LOUVER VAR VAPOR ARRESTOR TO RIGHT/TOP TO BOTTOM) CRN CRANE LU LUBRICATOR VX VAPOR EXTRACTOR CRSH CRUSHER MH MANHOLE VAV VARIABLE AIR VOLUME 01 THROUGH 99 CYCL CYCLONE WDW WINDOW WIN WINCH SERVICE NAMES & ABREVIATIONS AC HEATING VENTILATION & AIR CONDITIONING CS CONDENSATE MAKEUP & STORAGE GH GENERATOR HYDROGEN AH ASH CONDITIONING CT CHEMICAL TREATMENT GS GENERATOR SEAL OIL AS AUXILIARY STEAM CV CONDENSER, VACUUM HB HEATER BLEED THIRD & FOURTH NUMBER AV ATMOSPHERIC VENT CW CITY WATER (POTABLE) HD HEATER DRAIN SEQUENTIAL NUMBERING BA BREATHING AIR CWR COOLING WATER RETURN HO HYDRAULIC OIL BD BLOWDOWN CWS COOLING WATER SUPPLY HR HEATER RELIEF BF BOILER FUEL DMW DEMINERALIZED WATER HV HEATER VENT BFW BOILER FEED WATER DR DRAIN LINE IA AIR INSTRUMENT AIR BG BOILER AIR AND GAS DW DRINKING WATER LS LOW PRESSURE STEAM BS BOILER STEAM ES ELECTRIC SUPPLY MW MAKEUP WATER CA COMPRESSED AIR (ES -VOLTAGE) MS MEDIUM PRESSURE STEAM CC CONTAINMENT CONDENSATE FG FUEL GAS NG NATURAL GAS CO CARBON DIOXIDE FO FUEL OIL PA PLANT AIR CH COAL HANDLING FP FIRE PROTECTION PD PLANT DRAINS CM CONDENSATE FW FIRE WATER PW PROCESS WATER CNG COMPRESSED NATURAL GAS RD ROOF DRAINS SY n. REVISION RECORD NO DATE DESCRIPTION fu Fr z� 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE t r� 04/01/2019 ISSUED FOR CONSTRUCTION FRAZER PENNSYLVANIA VIA i-f G 2 r /F M 6* 08/08/2019 AS -BUILT (610) 407-4100 4' NC Firm License # C-3035 Q, Civil & Environmental Consultants, Inc. KEGI.NET ``yr •'L��'+�Ga`Y` ey„ Keeystone NC FIRM LICENSE 1900 Center Park Drive - Suite A -Charlotte, NC 28217 ENGIN EERING GROUP #C-4604 Ph: 980.237.0373 • Fax: 980.237.0372 -4/a/Z.")/ www.cecinc.com 7 6 5 4 2 1 CONTROL VALVE ACTUATOR SYMBOLS TMANUAL OPERATOR DIAPHRAGM PRESSURE BALANCED DIAPHRAGM HANDWHEEL WITH ACTUATOR CYLINDER - PISTON M MOTOR OPERATOR E/H ELECTRO-HYDRAULIC S SINGLE SOLENOID S M SINGLE SOLENOID - MANUAL RESET S SINGLE SOLENOID - REMOTE RESET R INSTRUMENT SUPPLY (CONNECTION TO PROCESS) # # # PNEUMATIC SIGNAL SOFTWARE OR DATA LINE MECHANICAL LINK - - DOUBLE WALL PIPE SYSTEM INSULATED PIPING CAPILLARY TUBING (FILLED SYSTEM) - - - - ELECTRICAL SIGNAL INTERFACE LINK BINARY ELECTRICAL SIGNAL HYDRAULIC SIGNAL ELECTROMAGNETIC OR SONIC SIGNAL IA INSTRUMENTATION AIR SUPPLY PIPING LINE SYMBOLS PRIMARY PIPING SECONDARY PIPING EXISTING PIPING sCQ► SLOPE PIPING ► TEMPORARY PIPING - - - _01110 HEAT TRACED PIPING TIE-IN POINT OFF —PAGE CONNECTOR RS RAW SEEP RW RAW WATER SA SERVICE AIR DRAWING P403 DRAWING P404 SC STEAM CONDENSATE CONNECTOR CONNECTED TO CONNECTOR CONNECTED FROM SO SEAL OIL NUMBER DRAWING NUMBER NUMBER DRAWING NUMBER SS SANITARY SEWER STS STORM SEWER SW SERVICE WATER 101 P404 101 P403 WT WASTE WATER TREATMENT FROM T-100 TO P-100 WW WASTE WATER FROM TO EQUIPMENT EQUIPMENT NUMBER NUMBER 1 ABBREVIATIONS ATC AIR TO CLOSE H ATO AIR TO OPEN Al ANALOG INPUT AO ANALOG OUTPUT AVG AVERAGE B/EL. BOTTOM ELEVATION BLD'G. BUILDING BOG BIOGAS CENTERLINE C&R COATED & WRAPPED (BURIED SECTIONS) C.W.L. CONTROL WATER LEVEL CFM CUBIC FEET/MINUTE 0 OR DIA. DIAMETER DI DIGITAL INPUT DO DIGITAL OUTPUT DWG. DRAWING ECC. ECCENTRIC E&C E&C MANAGEMENT SERVICES INC. G EL. ELEVATION ETC ENERGIZE TO CLOSE ETO ENERGIZE TO OPEN FC FAIL CLOSE FLP FAIL IN LAST POSITION FO FAIL OPEN FRL FILTER/REGULATOR/ LUBRICATOR FLR. FLOOR FD FLOOR DRAIN GAL. GALLON(S) GPD GALLONS/DAY GPH GALLONS/HOUR GPM GALLONS/MINUTE GRAV. GRAVITY FLOW HT&I HEAT TRACE & INSULATED HI HIGH H.W.L. HIGH WATER LEVEL F HP HORSEPOWER HB HOSE BIBB I.D. INSIDE DIAMETER IA INSTRUMENT AIR IN INSTRUMENT NITROGEN INV. INVERT LO LOW LWL LOW WATER LEVEL MBG MEDIUM BTU GAS MH MANHOLE MW MANWAY NC NORMALLY CLOSED NO NORMALLY OPEN N.W.L. NORMAL WATER LEVEL O.D. OUTSIDE DIAMETER PSIG POUNDS/SQUARE INCH GAUGE R. OR RAID. RADIUS E RED. REDUCER RED'G. REDUCING SCH. SCHEDULE S.P. SET POINT S.W.H. SIDE WALL HEIGHT S.W.D. SIDE WATER DEPTH SCR SILICON CONTROLLED RECTIFIER SP.GR. SPECIFIC GRAVITY SQ. SQUARE STD. STANDARD SCFM STANDARD CUBIC FEET/ MINUTE SWP STANDARD WEIGHT (STEEL PIPE) T/EL. TOP ELEVATION TDH TOTAL DYNAMIC HEAD VAC VACUUM D V.O.V. VALVE ON VERTICAL VFD VARIABLE FREQUENCY DRIVE VS VARIABLE SPEED W.C. WATER COLUMN W.D. WATER DEPTH W.L. WATER LEVEL W.V. WORKING VOLUME XS EXTRA STRONG (STEEL PIPE) NOTES: 1. THIS IS A GENERALIZED LEGEND SHEET. THIS PROJECT MAY NOT USE ALL INFORMATION SHOWN. 2. INSTRUMENTATION SYMBOLS AND IDENTIFICATION ARE BASED ON PROCESS INDUSTRY PRACTICES (PIP) STANDARDS AS BUILT DRAWING NO.: MOUNTAIRE FARMS, INC PROCESS & INSTRUMENTATION WASTEWATER TREATMENT LEGEND SHEET SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS 002 LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: NTS CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT SHEET OF 3 2 1 EIO ■ 0 ■ Io 11111111110 0 1 7 1 6 1 0 1 1 1 0 I BISULFITE (BY CHEMICAL SUPPLIER) PROCESS WASTEWATER G(GRAVITY FLOW) IOC IJ = 111111111110 0 m o. U_ 1 0 EXISTING EQ. BASIN (330, 000 GAL.) POL YMER REAGENT I o EXISTING SORIN DAF A (800 GPM) POL YMER REAGENT _-I I EXISTING SORIN DAF B (800 GPM) POL YMER REAGENT o T-220J EXISTING SORIN DAF C (800 GPM) POLYMER REAGENT (MATCH EXISTING) (MATCH EXISTING) 0 T-2214 NEW DAF D (WORLD WATER WORKS OR ENGINEER APPROVED EQUAL) (800 GPM) REVISION RECORD NO DATE DESCRIPTION t 08/16/2018 REVISED NEW DAF NOTE zL 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE zz, 6 04/01/2019 ISSUED FOR CONSTRUCTION 08/01/2019 AS -BUILT /Zl)� 9 7 1 0 0 0 T-3201 EXISTING ABOVEGROUND SUMP ormer Existing Clarifier) L� EXISTING — MBBR FEED PUMPS Qf W J W W D Cn NC W' W J D_ D_ J Q U � g W W O U W >_ W � m NEW MBBR No. 2 EXISTING WORLD WATER WORLD DAF (2400 GPM) 2— NEW SLUDGE TRANSFER PUMP —S S S7 14k CIO '4k F-- TO LAGOON EXISTING PUMP I CONTAINMENT CURB TO TRUCK LOADING m© III w =1A TEMPORARY SLUDGE STORAGE TANK (3 FRAC TANKS) p ---------- � I TO PROCESSING PLANT NO -J � � I EXISTING PLANT ----REUSE PUMPS-------- ----- — — — — —-------- (� � —Op- BYPASS TO LAGOON V S S S S S S S S S S— -S S S S S S —S S S S S S S S S S S S S S S� PRIMARY SOLIDS C 0 (TO TRUCK/HAULING) V) �S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S SPRIMARY SOLIDS � (TO TRUCK/HAULING) J Q U � g W W O U W � W � m FA a Q a a a a LA A NEW MBBR No. 1 T1 a a a II I I a II a a a o II II II NO — NEW BLOWERS (4,200 SCFM @ 15 PSIG) FRAZER, PENNSYLVANIA (610) 407-4100 Keystone NC FIRM ET NC FIRM LICENSE ENGINEERING GROUP #C-4604 5 fl—A 'W Aw VIAVI M 7 MOUNTAIRE FARMS, INC NC Firm License C-303 WASTEWATER TREATMENT Civil & Environmental Consultants, Inc. SYSTEM UPGRADE DATE: 1900 Center Park Drive - Suite A - Charlotte, NC 28217 LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: WWW.cecinc.com APPROVED BY: 4 3 2 n PROCESS FLOW DIAGRAM APRIL 2018 DRAWN BY: CHECKED BY: AS BUILT DRAWING NO.: 010 SHEET OF JKS GPT/MDW 174-540 GPT 1 111111010 _FA 8 7 6 5 4 3 2 1 SPEED SI LAL LAH IND. 1402 H YI YA 1301 1301 1401 01 LI ZI 14IN YI YA A 11T'r" 'I An,l 1 An1 RUNNING ALARM 1301 OIT -- -- --�-- LEVEL -- -- -- -- -- RUN FAULT LI YI 30 40 PLC — — — — — —3:DIl HO — — HI _HO Ml 1:A0 ------ -7 17 G I I S/S RUNNING HS YI I I RUN IND. HOA RU I II YL HS 140241 41 42 VFD YA SPEED SI SPEED SI IND. 1403 IND. 1404 IN ZI YI YA IN rZI Y AUTO l 403 l 403 1403 AUTO 1404 14 — — — — RUN FAULT — — — — — — RUN FAULT YI YI 40 40 3 DI 1 DO 1 AI 1:A0 3 DI 1 D0 1 AI 1 A0 ...... -7 7_�__ 7 N IND. 14 3 I I HOA 1403 I RUN IND. 1404 I HOA 1404 1401 YI YA FAULT FVNR I 1402 1402 1403 1403 RUNNING AULT I RUNNING'FAULT I I F MCC-1 I MCC-1 19 ■ o■ 0■ 0■ FROM PR❑CESSING PLANT 0 VFD I I I \ I I I I LIT I I 1301 I I M LE 1301 I I T-1201 EQUALIZATION TANK VOLUME: 330,000 GAL MATERIAL: CONCRETE E-1401 AERATOR MANUFACTURER: ?? MOTOR HP: ?? °"" "' REVISION RECORD NO DATE DESCRIPTION 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE t`04/01/2019 ISSUED FOR CONSTRUCTION e, 08/01/2019 AS -BUILT 4+ a /Zo I ? 7 6 V-1102 TO DRAIN P-1402 PRIMARY DAF FEED PUMP PUMP MAN.: GORMAN RUPP PUMP MODEL: T6A-13-4 PUMP TYPE: CENT. PUMP MOTOR: 30 HP (VFD) DESIGN FLOW: 800 GPM © 68 FT (DEDICATED FLOW TO T-2201) Do- V-1103 FRAZER, PENNSYLVANIA (610) 407-4100 Keystone NC FIRM ET NC FIRM LICENSE ENGINEERING GROUP #C-4604 0 REAGENT MII YI 1404 RUNNING • V-1102 V-1103 TO DRAIN VFD YA 1404 AULT REAGENT M I PI PI � 1307 1306 TO DRAIN RUN INDFYL1405 YI 1405 RUNNING SPEED SI IND. 1405 IN ZI YI YA AUTO l 405 1405 1405 -- -- RUN FAULT -- -- -- YI 40 — — — 3:DI ITT t-1:AI 1:A0 7_7 V-1108 V-1109 P-1403 P-1404 PRIMARY DAF FEED PUMP PRIMARY DAF FEED PUMP PUMP MAN.: GORMAN RUPP PUMP MAN.: GORMAN RUPP PUMP MODEL: T6A-13-4 PUMP MODEL: T6A-13-4 PUMP TYPE: CENT. PUMP TYPE: CENT. PUMP MOTOR: 30 HP (VFD) PUMP MOTOR: 30 HP (VFD) DESIGN FLOW: 800 GPM @ 68 FT DESIGN FLOW: 800 GPM © 68 FT (DEDICATED FLOW TO T-2202) (DEDICATED FLOW TO T-2203) NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com m N HS 1405 VFD YA 1405 AULT I REAGENT- - OIT — ■ ■ 1■ RW ��.�--Do----♦---�-1 103 1 013 V-1111 V-1112 I TO PRI DAF (T-2204) 1309 I V-1115 I TO DRAIN I RW E --------+— 102 013 TO PRI DAF (T-2203) I V-1114 D RW - — — — — — — — — — — — — — — — — — — — — 4—d 101 1 012 TO PRI DAF (T-2202) V-1113 I RW ------------L- 1 100 012 C TO PRI DAF (T-2201) P-1405 PRIMARY DAF FEED PUMP AS BUILT B PUMP MAN.: GORMAN RUPP 0 PUMP MODEL: T6A-13-4 PUMP TYPE: CENT. PUMP MOTOR: 30 HP (VFD) DESIGN FLOW: 800 GPM © 68 FT (DEDICATED FLOW TO T-2204) DRAWING NO.: MOUNTAIRE FARMS, INC PROCESS & INSTRUMENTATION DIAGRAM WASTEWATER TREATMENT Oil SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT SHEET OF 3 2 1 ■ FA 7 I 6 5 4 3 2 1 H G F E Ic C 0 OIT PLC FLOW FLOW FI Q FI 30 30 30 30 1AI 1:AI I I I / / PLC RW r---- I I -------------� ------F----------- \ 104 014 TO CLARIFIER I I M I I \ \ I I ( I 1 IL I I I I I I I I I M I I I I I I I I � I 11 - J I I FLOAT SOLIDS TO FIT I I L FIT I I OFFSITE RENDERING _ _ _ _ _ _ _ 0 I I J PLANT I I �------- FE I I ---- 2301 I I I RW71�E 100 011 FROM FF PUMP (P-1402) P❑LYER FEED RW 101 1 011 FROM FF PUMP (P-1403) POLYMER FEED n V-2101 NO V-2105 / — — — — — J I V-2104 V-2106 a s PLANT A A PI AIR V-2102 V-2103 REVISION RECORD DATE DESCRIPTION 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION 08/01/2019 AS -BUILT 7 T-2201 (PRIMARY DAF 'A') MANUFACTURER: SORIN HYD LOAD RATE: 800 GPM SOLIDS LOAD RATE: ??? MATERIAL: STAINLESS STEEL Keystone ENGINEERING GROUP FIT 302 FE L 302 -------�I❑I�---- V-2107 I I I —I—lit—►--� I I I /I I I V-2111 / I ---_j I V-2110 V-2112 a s PLANT A A PI AIR V-2108 V-2109 T-2202 (PRIMARY DAF 'B') 0 MANUFACTURER: SORIN HYD LOAD RATE: 800 GPM SOLIDS LOAD RATE: ??? MATERIAL: STAINLESS STEEL SOLIDS TO UFI-bIIL RENDERING PLANT AS BUILT DRAWING NO.: OIT H G F E 0 C 0 FRAZER, PENNSYLVANIA (610) 407-4100 KEGI.NET NC- FIRMLICENSE AV NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 •Fax: 980.237.0372 MOUNTAIRE FARMS, INC WASTEWATER TREATMENT SYSTEM UPGRADE LUMBER BRIDGE, NORTH CAROLINA PROCESS &INSTRUMENTATION DIAGRAM 012 A DATE: APRIL 2018 DRAWN BY: JKS DWG SCALE: CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT WWW.cecinc.com SHEET OF 5 4 3 2 1 y ■ G ■ 9 FAL FQI r FAL FQI H 2303 2303 2304 2304 H FI FI FLOW 2303 FLOW 2304 OIT OIT FI Q FI 30 30 30 30 PLc 1:AI 1AI PLC MO 01 I 191 FIT 303 FE 303 D RW 102 1 011 FROM FF PUMP P-1404 RUN IND. HOA 2203 2203 FAULT 2203 \ RW O TO CLARIFIER 4 I 1 I 1 I � I I RW r-----------�-----t--------------- 113 014 1 TO CLARIFIER I I I I 1 M I I I I I L I I I FLOAT SOLIDS TO _______ PLANT OFFSITE RENDERING I I I '^"' J�------- I I � I V-2117 Ta�_ II V-2116 V-2118 W� I 1 _ I --Jfif`—♦--J 1 FLOAT SOLIDS TO FIT I i I I OFFSITE RENDERING PLANT PLANT A A PI 304 I I I M AIR V-2114 V-2115 RW I 1 103 1 011 ----- ►----------— — — — — — — — — — — — — — FROM FF PUMP (P-1405) V-2119 I I �—�—" til23 , c-------------------------------------------------------------------------------------- fi--------i V— 2122 V— 2124 POLYMER FEED I Q POLYMER FEED PUMP I LANT s � PI IAIR V-2120 V-2121 A A I I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ---------J FROM EXISTING FEED TANK POLYMER FEED PUMP 0 01 raI P❑LYER FEED u d" p V-2113 REVISION RECORD NO DATE DESCRIPTION Al 08/16/2018 REVISED NEW DAF NOTE A 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION A4\ 08/01/2019 AS -BUILT 7 U. T-2203 (PRIMARY DAF 'C') MANUFACTURER: SORIN HYD LOAD RATE: 800 GPM SOLIDS LOAD RATE: ??? MATERIAL: STAINLESS STEEL FRAZER, PENNSYLVANIA (610) 407-4100 Keystone FI ET INCNC FIRM LICENSE ENGINEERING GROUP #C-4604 5 0 MANUFACTURER: MOYNO MODEL: 356 TYPE: PROS. CAVITY MOTOR: 2HP TEFC FLOW RATE: T-2204 (PRIMARY DAF 'D') MANUFACTURER: SORIN OR ENGINEER APPROVED EQUAL HYD LOAD RATE: 800 GPM SOLIDS LOAD RATE: ??? MATERIAL: STAINLESS STEEL AS BUILT 0 Q2 DRAWING NO.: 'W AF/7 MOUNTAIRE FARMS, INC PROCESS & INSTRUMENTATION DIAGRAM NC Firm License # C-3035 WASTEWATER TREATMENT 013 Civil & Environmental Consultants, Inc. SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS 1900 Center Park Drive - Suite A - Charlotte, NC 28217 LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: CHECKED BY: GPT/MDW Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: 174-540 www.cecinc.com APPROVED BY: GPT SHEET OF 4 3 2 1 G 10 IIA In C a A 0 II F 5 4 3 2 1 1:1 G F E ❑c C OIT PLC LAL LAH SPEED SI SPEED SI \ SPEED SI SPEED SI IND. 3401 IND. 3402 IND. 4401 IND. 4402 03 FAL FQI 3301 3301 LI IN ZI YI YA IN ZI YI YA IN ZI YI YA IN ZI YI YA FI AUTO 3401 3401 3401 AUTO 3402 3402 3402 AUTO 4401 4401 4401 AUTO 4402 4402 4402 4303 LEVEL 3301 RUN FAULT RUN FAULT RUN FAULT RUN FAULT FLOW LI yI YI YI YI FI 30 40 40 40 440 303 303 I— — — — — — — 1AI — — — — — — — — 3:DI HO 1:AI 1:A0 — — — 3:DI HO I AI 1:A0 — — — — — — — — 3:DI— ITO 1AI —1:A0 — — 3:DI HO 1:AI — 1:A0 — — Ml — — — — I I I I I I I I RUN IND. HOA I RUN IND. HOA I RUN IND. HOA I RUN IND. HOA YL HS YL HS YL HS YL HS 3401 3401 3402 3402 4401 4401 J44O2 4402 I I VFD VFD VFD VFD I YI YA YI YA YI YA YA 3401 3401 I 3402 34024401 4401I 4402 RUNNING AULT RUNNING AULT RUNNING AULT RUNNING AULT I I I I I I I WW I I I 105 016- — — — — — - MCC-1 I MCC 1] MBBR OVERFLOW I I I RW 104 1 012/013 - FROM PRIMARY PRIMARY DAFS I ILIT I I I I I RW I 3301 113 1 013 --, i LE TO CLARIFIER I I 3301 I -------- ----------- I I I I I ---------�---� M PI 3302 I l ----���� V-3102 — I V-3101 (RELOCATED) I I I I I I I I I I I I I INSTALL NEW 10" CHECK VALVE, I I NEW 10" TEE IN VERTICAL LINE AND — — ► VALVE. MODIFY PIPING AS NEEDED FOR CHECK VALE COORDINATE TIIEv N I WITHLOWN R I I L— I I I L-------- PLC OIT I I I I WW OVERFLOW TO LAGOON I I I I I I I W -------►------T--------------------------------�----------I------------------------- 106 015 TO MBBR REACTORS I I I I I I M PI I I I I \ 3303 I I I FIT I I J 4303 V-3104 M PI FE V-3103 (RELOCATED) 4301 30 I 4303 WW ► — — V-4102 V-4103 PLANT REUSE WATER FEED V-4101 INSTALL NEW 10" CHECK VALVE, NEW 10" TEE IN VERTICAL LINE AND VALVE. MODIFY PIPING AS NEEDED FOR CHECK VALVE INSTALLATION. COORDINATE TIE—IN WITH OWNER B T-3201 P-3401 P-3402 P-4401 ABOVEGROUND SUMP MBBR FEED PUMP No. 1 MBBR FEED PUMP No. 1 PLANT REUSE PUMP No. 1 VOLUME: 17,000 GAL PUMP MAN.: GORMAN RUPP PUMP MAN.: GORMAN RUPP PUMP MAN.: GOULDS MATERIAL: STAINLESS STEEL PUMP MODEL: T10A-60S-13 PUMP MODEL: T10A-60S-13 PUMP MODEL: 66SV41 GF30 PUMP TYPE: CENT. PUMP TYPE: CENT. PUMP TYPE: CENT. PUMP MOTOR: 30 HP (VFD) PUMP MOTOR: 30 HP (VFD) PUMP MOTOR: 40 hp DESIGN FLOW: 2250 GPM @ 36 FT DESIGN FLOW: 2250 GPM @ 36 FT DESIGN FLOW: 350 GPM e t/��9 n REVISION RECORD NO DATE DESCRIPTION Q 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE Q 01/31/2019 REVIEW FOR CONSTRUCTION ISSUE 3 04/01/2019 ISSUED FOR CONSTRUCTION /4\ 08/01/2019 1 AS -BUILT 7 U. Keystone ""*� ENGINEERING GROUP I — � )1k 1105 V-4106 V-4104 P-4402 PLANT REUSE PUMP No. 1 PUMP MAN.: GOULDS PUMP MODEL: 66SV41 GF30 PUMP TYPE: CENT. PUMP MOTOR: 40 hp DESIGN FLOW: 350 GPM AS BUILT 2 Al DRAWING NO.: H G F E C 0 AV AV AIF FRAZER, PENNSYLVANIA (610) 407-4100 KEGI.NET NC- FIRMLICENSE AV NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 •Fax: 980.237.0372 MOUNTAIRE FARMS, INC WASTEWATER TREATMENT SYSTEM UPGRADE LUMBER BRIDGE, NORTH CAROLINA PROCESS &INSTRUMENTATION DIAGRAM 014 A DATE: APRIL 2018 DRAWN BY: JKS DWG SCALE: CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT WWW.C@CInc.com SHEET OF 5 4 3 2 1 mm ©. 0 � IAM 0 � 0M [am 8 7 6 5 4 3 2 1 FAL FQI FAL FQI SPEED 7 SI SPEED SI SPEED SI 5301 5301 5302 5302 IND. 5403 IND. 5404 IND. 5405 FI ZI FI FI IN ZI YI YA IN ZI YI YA IN ZI YI YA 5301 5102 5302 5105 AUTO 5403 5403 5403 AUTO 5404 5404 5404 AUTO 5405 5405 5405 01 T FLOW POSITION FLOW POSITION RUN FAULT RUN FAULT RUN FAULT 01 T FI Q ZI FI QS YI S YI S YI 30 30 10 30 30 10 30 40 30 40 30 40 tpLc 11AI 21AI 1:A0 IIAI 21AI 1:A0 11EH1 31DI HO 11AI 1:A0 11EH1 31DI HO 11AI 1:A0 11EH1 31DI 1TO IIAI 1:A0 PLc T- -7-7- I I RUN IND. HOA I RUN IND. HOA I RUN IND. HOA 1 1 I YL HS YL HS YL HS 5403 5403 5404 5404 5405 5405 HOA , HOA HS I I 5401 I I 5402 I I I YI YA / 1 YI YA YI YA 5403 5403 I 5404 54A 5405 5405 >\ I � RUNNING I RUNNING RUNNING FVR I FVR FAULT I FAULT I I FAULT I VFD I I VFD 1 VFD MCC-2 MCC-2 1 I I I I I I , BLOWER CP I I BLOWER CP I , I BLOWER CP I , I I I I I I I I I I I I I I I I I I I I I I I � I PSH I I 5304PI I I I I I I I I I 304 5I I I I I I I I I I I �1113.1 .IN WIN I , A A AI IA A I AIR JE A A A A I A A A AAA A AAA A 016 I I I V-5107 V-5108 I AIR SUPPLY (MBBR #1) I I I I I 53 6 PI I I I f V-5114 TE M I I 5306 , I 1 5303 8-ma-0 I I I � A A A A A A A AAA V-5109 V-5110 I PSH B —5403 I I 5308 PI f V-5113 53 , I TE M 08 5305 8 1 1 AIR D I I v-5111 v-� 2 A A A A A A A A AIR S O SUPPLY (MBBR #2) B-5404 , FIT 5301 I , 1 TE M FE I I 5307 V 5301 I 1 I W W I 1 B-5405 W W 106 1 014 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ►— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 109 016 FROM MBBR FEED PUMPS I V-5101 V-5102 V-5103 I WW FEED (MBBR #1) FIT 5302 5 PIPE 2 PIPE DIAMETERS DIAMETERS F E CLEAR CLEAR 5302 I WW L-- — — — — — — — — - po --- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 110 016 V-5104 V-5105 V-5106 WW FEED (MBBR #2) 5 PIPE 1 2 PIPE DIAMETERS DIAMETERS CLEAR CLEAR V-5102/5401 V-5105/5402 MBBR No. 1 PINCH VALVE 0 MBBR No. 2 PINCH VALVE 0 MAN.: ONYZ OR ENGINEER APPROVED EQUAL MAN.: ONYZ OR ENGINEER APPROVED EQUAL MODEL: 16" SERIES DEC MODEL: 16" SERIES DEC TYPE: FULL ROUND PORT TYPE: FULL ROUND PORT PORT SIZE: 16" X 10" X 10" RED.PORT PORT SIZE: 16" X 10" X 10" RED.PORT ACTUATOR: EIM ELECTRIC ACTUATOR: EIM ELECTRIC SLEEVE MAT: EPDM SLEEVE MAT: EPDM rr q. REVISION RECORD NO DATE DESCRIPTION t f J° gyp: 08/16/2018 ADDED ENGINEER APPROVED EQUAL B-5403 Q MBBR No. 1 BLOWER 1 MAN.: (EXCELSIOR OR ENGINEER APPROVED EQUAL MODEL: HE 250 CDL 700 TYPE: SCREW P.D. FLOW RATE: 4400 SCFM ® 15 PSIG MOTOR FLA: 515A @ 460V A 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE FRAZER PENNSYLVANIA I;6 2 04/01/2019 ISSUED FOR CONSTRUCTION (610) 407-4100 t' = o. ` 08ro1/2019 AS -BUILT KEGI NET 4+/t/Z,31? 0' Keystone NC FIRM LICENSE #C-4604 ENGINEERING GROUP 5 M 0 B-5404 0 520 0 AS BUILT B MBBR BLOWER MBBR No. BLOWER 0 MAN.: (7EX�C�ELSIORNGINE OR EEEU R APPROVD EQAL MAN.: EXCELSIOR OR ENGINEER APPROVED EQUAL A: H250 CDL 700 (TYP. ALL BLOWERS) TYPE: SCREW P.D. MODEL: HE 250 CDL 700 FLOW RATE: 4400 SCFM @ 15 PSIG TYPE: SCREW P.D. MOTOR FLA: 515A ® 460V FLOW RATE: 4400 SCFM © 15 PSIG MOTOR FLA: 515A ® 46 0 V .. .. .. .. .. .. .. .. .. .. .. I AV AVAV AV A NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com DRAWING NO.: MOUNTAIRE FARMS, INC PROCESS & INSTRUMENTATION DIAGRAM WASTEWATER TREATMENT 015 SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT SHEET OF 3 2 1 FA 8 1 7 0 5 4 3 2 1 H G F E AAL AAH 5309 5309 AI 5309 01 T pH/ORP AAH AAL r LAL LAH 5313 5313 5314 5314 'Al YI LI 5313 5122 OPEN 5314 pH/ORP I — DO/TEMP — LEVEr"IL AI AI ZI LI AI AI ZI LI 309 31 11 31 31 313 12 31 LAL LAH 5311 5311 YI LI 5116 OPEN 5311 DO/TEMP LEVEL 2:AI 2:AI ITT IAI 2:AI 2:AI ITO 2AI n-------------------7---1---1--------L---------4---------------------------------� A A A A 1 1"0 AIR SUPPLY LINE I I I I I 1 I I I I I I 1 pH/ORP DO/TEMP V-5121 A AT AT V-5116 S I I I I I I 1F 5309 5310 Q I V-5115 IQ D-----r-------------------------------7--- 7------- ------------------------------, I 1 FI Q A A I I I I I I I I I I 1 Q _ I SEE NOTE 23, --- ►----------------------------------�- I I I SEE SHT 001 I I V-5r1 9 I I I-----T--------- �-----------, I V— 5120 1 1 "0 AIR SUPPLY LINE I I 1 I Q I 1 i 1 i i I I I i I I pH/ORP DO/TEMP I I I I / A 5312 5313 V-5122 S I 1 1 I I I I Q I I WW I I I I I I I L-----�--� ---� ---�, I I D —t--- -- -------------J---�— 105 014 OVERFLOW (T❑ CLARIFIER) SEE 231 Q I I SEE SHTE001 ' I A A-TF I I I I W W Q I I I I 1 I I I po- -----►-----1-------------►-- i11 017 V-5125 TO SECONDARY DAF I I Q I I I I I I I I I I I I I I I I Q I I I Q 1 I I I I I I I I I I Q I I I I Q I I I 1 i I I I i Q Q I pH DO LT I I 5311 I ----------- I AE AE LE 1 Q I D CHEM FEED (DEF❑RMER) I Q 5309 5310 5 11 (BY CHEMICAL SUPPLIER) Q I V-511 11 C 111 A PLC L — I T T T T T T T T T T I I V-5117 Q � I AIR I � 107 1 015 A A A A A BLOWER #1 AIR SUPPLY I � WW 109 015— — — — — — — — — — - No ------------J I MBBR #1 WW FEED Q I I AIR 1 108 015 A A A A A A A A A A A A A A A A A A A A A 1 BLOWER #2 AIR SUPPLY I WW 110 1 015-----------------------------------------►------------------------------------------J MBBR #2 WW FEED J. Erm NO T-5201 MBBR No. 1 TANK I I I I I I .—.j V-5123 T-5202 0 AS BUILT MBBR No. 2 TANK Al MAN.: TBD MAN.: TBD TYPE: BOLTED 304SS TYPE: BOLTED 304SS VOLUME: 445,000 GALLON VOLUME: 445,000 GALLON DIAMETER: 51'-6 7/8" DIAMETER: 51'-6 7/8" HEIGHT: 35 FT (SWD @ 29 FT) HEIGHT: 35 FT (SWD @ 29 FT) REVISION RECORD DATE DESCRIPTION 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE 01/31/2019 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION 08/01/2019 AS -BUILT 7 U. Keystone "*� ENGINEERING GROUP DRAWING NO.: H G F E C 0 AV VIA A F /F MOUNTAIRE FARMS, INC PROCESS & INSTRUMENTATION DIAGRAM FRAZER, PENNSYLVANIA (610) 407-4100 NC Firm License # C-3035 WASTEWATER TREATMENT 016 KEGI.NET Civil & Environmental Consultants, Inc. SYSTEM UPGRADE A NC- FIRMLICENSE 1900 Center Park Drive - Suite A - Charlotte, NC 28217 LUMBER BRIDGE, NORTH CAROLINA DATE: APRIL 2018 DRAWN BY: JKS DWG SCALE: CHECKED BY: GPT/MDW Ph: 980.237.0373 •Fax: 980.237.0372 PROJECT NO: 174-540 WWW.cecinc.com APPROVED BY: GPT SHEET OF 5 4 3 2 1 rn H F E n Al EXISTING EXISTING FEED EXISTING EXISTING EXISTING EQUALIZATION FORWARD TRANSFER SORIN DAF SORIN DAF SORIN DAF PUMPS BASIN 'B " "C " (TYP FOR 4) REVISION RECORD NO DATE DESCRIPTION Q 08/16/2018 REVISED NEW DAF NOTE 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION Q 08/01/2019 AS -BUILT 8 7 v v v v v v v v NEW DAF 'D " (WORLD WATER WORKS OR ENGINEER APPROVED EQUAL) Al EXISTING CLARIFIER AS BUILT MOUNTAIRE FARMS, INC FRAZER, PENNSYLVANIA (610) 407-4100 NC Firm License # C-3035 WASTEWATER TREATMENT KEGI.NET Civil & Environmental Consultants, Inc. SYSTEM UPGRADE Keystone DATE: #C-4160[+ LICENSE 1900 Center Park Drive - suite A -Charlotte, NC 28217 LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: ENGINEERING G R O U P Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: www.cecinc.com APPROVED BY: 6 5 4 3 2 LEGEND A FF FINISHED FLOOR I.E. INVERT ELEVATION SL STATIC WATER LEVEL TOP TOP OF PIPE TOT TOP OF BANK WL WATER LEVEL 3.2 MGD DESIGN FLOW 2.55 MGD DESIGN DRAWING NO.: HYDRAULIC PROFILE H r F E ri. C APRIL 2018 DRAWN BY: JKS 040 A CHECKED BY: GPT/MDW 174-540 GPT SHEET OF 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 H F E n 235 235 230 230 225 - -225 225 220 wrip 220 -215 215 215 » » SCREENS 210 210 205 205 10 NEW -TO 200 200 • dEL. � d ♦ d 197-5— d ♦ d Of TO EXIST 195Dn M M 195 ff ff 190 190 185 EXISTING TRANSFER PUMPS (TYP FOR 2) NEW M B B R REACTOR TANK No. 1 NEW M B B R REACTOR TANK No. 2 EXISTING WORLD WA TERWORKS DAF AS BUILT LEGEND Al FF I.E. SL TOP TOT WL EXISTING LAGOON FINISHED FLOOR INVERT ELEVATION STATIC WATER LEVEL TOP OF PIPE TOP OF BANK WATER LEVEL 3.2 MGD DESIGN FLOW 2.55 MGD DESIGN 185 v "^ ' ? 34:�'hL��° ` 1 t d.r y -F s •�`">=«a$�•°° E ,.. p I 1 REVISION RECORD Keystone ENGIN EERING FRAZER, PENNSYLVANIA (610) 407-4100 KEGI.NET NC FIRM LICENSE #C-4604 G R O U P AJV - - JAW NC Firm License # C 3035 Civil & Environmental Consultants Inc ° 1900 Center Park Drive - Suite A -Charlotte NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 WWW.cecinc.com MOUNTAIRE FARMS INC WASTEWATER TREATMENT SYSTEM UPGRADE LUMBER BRIDGE, NORTH CAROLINA I HYDRAULIC PROFILE DRAWING NO.: 041 SHEET OF NO DATE DESCRIPTION o 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE Q 04/01/2019 ISSUED FOR CONSTRUCTION 3 08/01/2019 AS -BUILT DATE: APRIL 2018 DRAWN BY: JKS DWG SCALE: CHECKED BY: GPT/MDW PROJECT NO: 174-540 I APPROVED BY: GPTI H re- Ir 7 C L ITA 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 H 8 1 7 1 6 1 5 1 4 1 3 1 2 1 H F 1t 0 a NORTH STORY WA TER POND :.c 3B O o 0 0 0 4, O lb 0 C REFERENCE A 1. SITE MAP SUPPLIED BY CABE °o ASSOCIATES, INC. OF DOVER, v DELAWARE. �A I n N a EXISTING SPRAY IRRIGATION PUMPING STATION EXISTING 410 PVC SDR 26 - WASH DOWN LINE EXISTING 31410 STEEL - SCH 40 AIR SUPPLY LINE \ EXISTING \\\X • SANITARY • SYSTEM \ EXISTING 110 PVC EXISTING 810 PVC SDR 26 TRUCK PARKING PAD DRAIN LINE EXISTING TRUCK PARKING EXISTING 610 PVC SDR26 J TREATMENT FEED EXISTING 410 PVC DWV FEED FORWARD PUMP STATION DRAIN LINE EXISTING PUMP STATION EXISTING 12 "0 PVC SDR 26-1 YARD DRAIN EXISTING 410 PVC SDR 26 WATER MAIN i EXISTING 1810 DI PROCESSING PLANT EFFLUENT REVISION RECORD .,fl:.�" a �� ;''•",> `'jr' V�✓S�.¢di.::^ cis NO DATE DESCRIPTION t: Jb " it' 7-19-18 ADDED OVERHEAD ELECTRICAL AND POWER POLES a v:' Q 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE 04/02/2019 ISSUED FOR CONSTRUCTION 08/08/2019 AS -BUILT � U3r006`` i1 �E; �'��F9ACU:1Q"s'+yp9J 7 FRAZER, PENNSYLVANIA (610) 407-4100 Keystone KEGI.NET NC FIRM LICENSE ENGINEERING GROUP #C-4604 6 5 [1AF MOUNTAIRE FARMS, INC NC Firm License C-303 WASTEWATER TREATMENT Civil & Environmental Consultants, Inc. SYSTEM UPGRADE DATE: 1900 Center Park Drive - Suite A - Charlotte, NC 28217 LUMBER BRIDGE, NORTH CARO LI NA DWG SCALE: Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: WWW.cecinc.com APPROVED BY: 4 3 2 SCALE IN FEET 0 40 80 EXISTING SITE PLAN DRAWING NO.: APRIL 2018 DRAWN BY: JKS 1" = 40' CHECKED BY: GPT/MDW 174-540 GPT SHEET 1 100 OF F E 0 C B 0 8 1 7 1 6 1 5 1 4 1 3 1 2 1 ti H NORTH Gi> F FE 0 C R v 0 h B w m �A n A N a EXISTING LAGOON No. 3 PROPOSED 16" 0 GRAVITY DISCHARGE LINE (SEE DWG. 130 EX/s TNG SAN/7�4RY 7;QE4 TMEIVT YSTEM FEED FORWARD\ PUMP STATION (SEE SHT 202) EXISTING ANAEROBIC LAGOON No. 2 REVISION RECORD DATE DESCRIPTION 7-19-18 ADDED OVERHEAD ELECTRICAL AND POWER POLES 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE �153 'LJi 04/01/2019 ISSUED FOR CONSTRUCTION /g� a 1 08/01/2019 1 AS -BUILT p s 8 1 7 PARKING H F E 0 C \ REFERENCE y 1. SITE MAP SUPPLIED BY CABE ASSOCIATES, INC. OF DOVER, DELAWARE. SCALE IN FEET B 0 40 80 AS BUILT DRAWING NO FRAZER, PENNSYLVANIA MOUNTAIRE FARMS, INC PROPOSED SITE LAYOUT PLAN (610) 407-4100 NC Firm License # C-3035 WASTEWATER TREATMENT 101 KEG I. NET Civil & Environmental Consultants, Inc. SYSTEM UPGRADE Keystone DATE: APRIL 2018 DRAWN BY: JKSA NC- FIRM LICENSE 1900 Center Park Drive - Suite A - Charlotte, NC 28217 LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: 1" - 40' CHECKED BY: GPT/MDW ENGINEERING GROUP 4604 Ph: 980.237.0373 •Fax: 980.237.0372 PROJECT No: 174-540 WWW.cecinc.com APPROVED BY: GPT SHEET OF 6 5 4 3 2 1 7 6 I 5 4 3 2 1 H NORTH G F n h N L a h �A I ELECTRICAL BOX - <� / / / / / NEW 16"0 C900 PVC LINE FROM EXISTING ABOVEGROUND SUMP TO NEW MBBR REACTOR TANKS / / // 18"0 C900 PVC \ �-------' — \ \ OVERFLOW \ \ / // TO EXISTING CLARIFIER \ ,< \\ \ NEW 18"0 C900 PVC EFFLUENT LINE TO WORLD WATER WORKS DAF (T-6201) / / 16"0 C900 PVC INFLUENT LINE ~ II Z W w V) Lw \ \ \ _ 8" x24" SCREEN \V A\ V A\ EFFLUENT MANIFOLD ON 8"0 DRAIN \\ \ \\ \\ I SEE NOTE 19 Q \ I C 232 Lr 18"0 C900 PVC OVERFLOW f1aasda •(,^' ��l °' 4aFt'L�a�ev -'44 /Z,? p REVISION RECORD NO DATE DESCRIPTION 7-19-18 ADDED OVERHEAD ELECTRICAL AND POWER POLES 9-5-18 ADDED THRUST BLOCKS 02/06/2019 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION n� A, 1 08/01/2019 1 AS -BUILT 7 I 77NEW 18"0 C900 PVC EFFLUENT LINE TO WORLD WATER WORKS I I DAF (T-6201) 18"0 C900 PVC OVERFLOW FRAZER, PENNSYLVANIA (610) 407-4100 Keystone KEGI.NET NC FIRM LICENSE ENGINEERING GROUP #C-4604 6 I 5 N co N 14' - 0>' BLOWER (TYP SPACING) (TYP. FOR 3) I 12"x12" S.S. FLEX �C�OUPLING (TYP. FOR 3) BUTTERFLY VALVE (TYP. FOR 3) 1 "x18" REDUCER P. FOR 3� 18" S.S. AIR 0 1 1 ANIFOLD 18" S.S. AIR 18"0 ISOLATION IMANIFOLD-------- VALVES --= I1 "0 AIR LINE TO Ill EFFLUENT MANIFOLDS EXACT ROUTE TO BE DETERMINED IN THE FIELD (TYP.) FLOW METER AND PINCH VALVE LOCATED INFLUENT SCREEN IN VERTICAL LINE - 16"X72", SEE NOTE 19 ',>I 12'-0" 16_3 I I EE NOTE'CR9EN S� Q (TYP. ALL SCREENS) MBBR No. 2 I I I I I I I I I L_--J PROPOSED CONCRETE PAD FOR FUTURE BLOWER (TYP. FOR 2) I I I I I I NEW PIPE SUPPORT (SEE DETAIL SHT 300) INFLUENT SCREEN 16" x72" MBBR No. 1 " EFFLUENT MANIFOLD SEE NOTE 19 Ill 7/ 1 "0 AIR LINE TO r EFFLUENT MANIFOLDS NEW 18"0 PVC BLIND FLANGE NEW 18"0 304 SS PIPE AV F/F VIA tA NC Firm License # C Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com 4 OVERHEAD ELECTRICAL 7 232 B BLOWER BUILDING NEW AERATION GRID (TYP. OF 2) COORDINATE GRID ANCHORS WITH TANK SUPPLIER 8"x24" SCREEN ON 8"0 DRAIN C 232 18" BLIND FLANGE THRUST BLOCK (TYP.) (SEE DETAIL ON SHEET 280) REFERENCE 1. SITE MAP SUPPLIED BY CABE ASSOCIATES, INC. OF DOVER, DELAWARE. SCALE IN FEET 1 a 20 AS BUILT DRAWING NO.: MOUNTAIRE FARMS, INC PROPOSED SITE LAYOUT PLAN WASTEWATER TREATMENT MBBR TANKS SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: 1" = 10' CHECKED BY: GPT/MDW PROJECT NO: APPROVED BY: 3 2 174-540 GPT SHEET 1 102 OF H F n C 0 0 n. 7 5 0 3 2 1 H NORTH G F ■ n EXISTING 61e RAW WATER INFLUENT LINE TO DAF "C " NEW 6"0 RAW WATER INFLUENT LINE TO NEW DAF ))D)) NEW SLUDGE NEW 2"x4" RI EXISTING PA z' �C NEW CONT AREA Q Q h 0 3 0 0 U O U I O h I3 w m I y Q 0 0 0 AF.•,:: 4,:�11a, aV�) REVISION RECORD ` NO DATE DESCRIPTION �, r 09/05/2018 REVISED NEW DAF NOTE t 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE o pp s: 04/01/2019 ISSUED FOR CONSTRUCTION A7 O �� t>r.� w 4 1 ;; +.-uu�r �q 08/01 /2019 AS -BUILT a 8 7 6 nirnnninirnr rvirrinin c i i innr FRAZER, PENNSYLVANIA (610) 407-4100 Keystone KEGI.NET NC FIRM LICENSE ENGINEERING GROUP #C-4604 6 1 5 LA A F /F AWIA AW AV FIAF NC Firm License # C Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com II ivtvv ) w Sun av rvu rirt NEW 12" S.S. EFFLUENT DISCHARGE LINE TO EXISTING CLARIFIER FROM REFERENCE 1. SITE MAP SUPPLIED BY CABE ASSOCIATES, INC. OF DOVER, DELAWARE. SCALE IN FEET 0 5 10 MOUNTAIRE FARMS, INC PROPOSED SITE LAYOUT PLAN WASTEWATER TREATMENT FRAC TANK AREA SYSTEM U PG RADE DATE: APRIL 2018 DRAWN BY: JKS LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: 1" = 5' CHECKED BY: GPT/MDW PROJECT NO: APPROVED BY: 3 2 AS BUILT DRAWING NO.: 174-540 GPT SHEET 1 105 OF H G F E n C 13 0 8 I 7 I 6 I 5 I 4 3 2 LEGEND 1 H G F E n 0 h B m hA I NORTH TYPICAL \ EOUALIZATION \ BASIN \ \ \ I / � 8 APPROXIMATE LOCATION OF EXISTING DITCH / / PROPOSED SEEDING THIS AREA (SEE SHEET 112 FOR SEEDING SCHEDULE) � 195 _ ��� / �h / PROPOSED BLOWERS 195 — / O A \\ \ \ \ \ \ �Q , FILTER SOCK1 I TYPICAL ------ —_ ____-- --/ 19 `, \\S � \\ / � � � PROPOSED / MBBR \ \ \ \ TANK \\ / No.1 7,9 Cb \ APPROXIMATE \ LOCATION OF - EXISTING COL INERT \ INVERT \ \ � PROPOSED MBBR EXISTING \ O ` TANK PUMP No.2 I I \ � / \ STATION // \ LIMITS OF DISTURBANCE: 0.85 ACRES / APPROXIMATE \ \\\ / // // 7� LOCATION OF _\� 01 EXISTING NSF 'Lc _ EXISTING ��'I'�'���C� TREATMENT / \ BUILDING � _ _/%/ PROPOSED WASTEWATER / __/ PIPE Q / �/ \ 0 411 p / ( 000, eloolf I � / _ I \ I\ 0 / REVISION RECORD NO DATE DESCRIPTION C;r ;"•,{??';;ir(: £'r, F'F?ry i'-�? �?, 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE "• !R S? 04/01/2019 ISSUED FOR CONSTRUCTION -%3\ 08/08/2019 AS -BUILT FRAZER, PENNSYLVANIA (610) 407-4100 Keystone NC FI ET NC FIRM LICENSE ENGINEERING GROUP #C-4604 6 I 5 NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com 4 / I \ I \ I � J AM EXISTING CONTOUR EXISTING NATURAL GAS EASEMENT EXISTING DITCH EXISTING WASTEWATER PIPE PROPOSED LIMITS OF DISTURBANCE PROPOSED WASTEWATER PIPE PROPOSED FILTER SOCK NOTES — — — — — — 196 ------ 1. SEE SHEET 112 FOR GENERAL NOTES 2. CONTRACTOR SHALL REFER TO OTHER PLANS WITHIN THIS DRAWING SET FOR OTHER PERTINENT INFORMATION. IT IS NOT THE ENGINEER'S INTENT THAT ANY SINGLE PLAN SHEET IN THIS SET OF DOCUMENTS FULLY DEPICT ALL WORK ASSOCIATED WITH THE PROJECT. 3. THE EROSION CONTROL MEASURES INDICATED ON THIS PLAN PROTECT ADJACENT PROPERTIES & WATERWAYS FROM RUN-OFF. THE CONTRACTOR WILL BE REQUIRED TO ADD/SHIFT & RELOCATE EROSION CONTROL MEASURES AS WORK PROGRESSES. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING THEIR COMPLETED WORK PRIOR TO COMPLETE STABILIZATION & SHALL NOT RECEIVE ADDITIONAL COMPLEMENTATION. 4. TOTAL LIMITS OF DISTURBANCE = 0.85 AC BEFORE YOU D101 CALL 1-800-632-4949 N.C. ONE —CALL CENTER rr8 THE LAWI NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C-3035 REFERENCE 1. SITE MAP SUPPLIED BY CABE ASSOCIATES, INC. OF DOVER, DELAWARE. SCALE IN FEET 0 20 40 AS BUILT DRAWING NO.: MOUNTAIRE FARMS, INC EROSION AND SEDIMENT CONTROL PLAN WASTEWATER TREATMENT 111 SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: MRJ LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: 1" = 20' CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT SHEET OF 3 2 1 H G F E n C 0 0 11 7 R E 1 z 9 F E IC C 0 A REFERENCE NORTH 0 w z 0 a w w 1. BASE MAP TAKEN FROM DRAWING PREPARED BY CRAWFORD DESIGN COMPANY OF SOUTHERN PINES, NC AND LOCKLEAR, LOCKLEAR & JACOBS OF PEMBROKE, NC. PROJECT No. 17044, DATE UNKNOWN. [u TOP OF BERM nn + c�n ------------799------- -200 201 -- — — — — — — 202 - — — — — — — - F-------------203------- I— — — — -- Jnn o-5 — — — — -204— --- ------ — --------- ----------------203------------------------- --------- ---- -------------203-------- ---— — — 204 -- -- �� ��--203--- 4" PVC (ON GRADE) ----- — -------------- --20. - — ///j�--202--- _ ------------------2G - ABANDONED POWER POLE �--201-- __ —200— - -------201------- — 200- I -------199-------- / APPROXIMATE WATER LEVEL STORYWA W Ld DETENTION = Ld N I I I I I II jI I I III I j 1 I INSTALL TYPE 2 _PIlstla l0 74 RESTRAINED JOINTS. SEE DETAIL SHEET 281 I I EXISTING POWER POLE I EXISTING MANHOLE BUILDING --37� 200 z_ / -201 - ---203------- INSTALL RESTRAINED2°4--- 5 1 4 1 3 -- — — — — �T --'—`----------- —199-- --- r — --------- -- _EXISTING 16" WASTE MAIN-- JOINTS. SEE TYPE 1 / ty/1/K4 / _3 3 DETAIL. SHEET 281 �� /-�_205�3-5n /—�� x x-7 \ \\ Pl/ St 1// O/ L O / C) C WATER VALVE PI Sta + 3 INSTALL TYPE 3 i II II RESTRAINED JOINTS. / + SEE DETAIL SHEET 281 —1z E-, 7 OVA x x x I j\I �\�+ X I / \-x x x / \� 0 + I x O F_ U w Z Z Z w O m U w Ljj 210 � o + + + + + + + + + + + + + + + + + 1 O O O O N N N N M M M n � REVISION RECORD NO DATE DESCRIPTION Al 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION �2 /a\ 08/01/2019 AS -BUILT 7 11 FRAZER, PENNSYLVANIA (610) 407-4100 Keystone NC FIRM ET NC FIRM LICENSE ENGINEERING GROUP #C-4604 5 I AV AV AV A A 1A F7 NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com 210 z 0 a w w AS BUILT DRAWING NO.: MOUNTAIRE FARMS, INC EFFLUENT PIPE PLAN AND PROFILE WASTEWATER TREATMENT STATION 0+00 TO 4+00 130 SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: 1" = 20' CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT SHEET OF 3 2 1 G F E IC C 0 I.1 r n 7 0 5 4 3 2 1 I:1 G F E Ic C 10 A IT z 0 w J W REFERENCE 215 NORTH -------- ----_ ��195 ------ _--------- ------ —196---------------------- ---198-- — — — — — — — — ---------797---------------- _ --------------- \ 201200�� \� INSTALL TYPE 1 -----------------201------ '� ` RESTRAINED JOINTS. -------------------- ------------------202----------------_ SEE DETAIL SHEET 281 ------------------------------------------ --------------------204------------------ 04---------- I — EXISTING POWER ------------------_204— POLES (2) PI Sta 6+96� OIr7 Li w� w w LO 6+00 6 — -- 204-- —— — — — — — — — — — — — — — — --------------------2(1- --------20J------------------------------------------------203---- 202----- --- -- - --------201-------------------- - - -----199-------------------- \ I I I I 215 I II I I I I I N O N O O N O N LO O N O O w) O v) N O N O O N O N N O N O O N O v) N O O O O O O O O O O O O O O O O M O O O O O L0 O O L0 O L0 Q O N LO M M O N (O [O n Ln a0 a0 O O Q O N LO M M It I Q N o o n Ln a0 a0 m m Q O N Ln M M Q N o (O n Ln aD aD a) a) O O N Ln M M O L0 O O n Ln aD w m m O O N Ln M M O M (O (O n Ln a0 a0 a) a) O Q + + + + N + + + + + + + + + + + + Q + + + + N + + + + + + + + + + + + Q + + + + N + + + + � + + + + + + + + Q + + + + N + + + + L + + + + + + + + O + + + + N + + + + � + + + + + + + + Q + + + + + + + + + + + + + + + + + + + + + -4- -4- "t -4- In L0 L0 L0 O O O c0 r- r- r- r- 00 00 00 00 O 1. BASE MAP TAKEN FROM DRAWING PREPARED BY CRAWFORD DESIGN COMPANY OF SOUTHERN PINES, NC AND LOCKLEAR, LOCKLEAR & JACOBS OF PEMBROKE, NC. PROJECT No. 17044, DATE UNKNOWN. [y NO REVISION RECORD DATE DESCRIPTION 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION 08/01/2019 AS -BUILT 7 U. Keystone "*� ENGINEERING GROUP A z 0 Q I w J W \\ III II II A II I ►II \ �I I III Pl�t4 J sI I \ / Ill Jill \ / III II III II II I / II II III II II \ �� /IIIIIIII I I I I IIII \ I \ I NoN I II \ I c� 00 I III�I111 \� +o co � I I I I I I I I I I I I I I I I IIIIIIIII 1 I I I I I I I I I I I I I I I I I I I I I I I I I I II I I j I II I I C I I I I I I I I I I I I I I I IIIIIIIII I �illl�illll I j l l l j l j I I I I I�Illil II o 0 I _ SHEET 132 0 0 N AS BUILT DRAWING NO.: G F E FBI C 0 AV AV FRAZER, PENNSYLVANIA (610) 407-4100 I . NET NC FIRM LICENSE #C-4604 AV - - F7 NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 •Fax: 980.237.0372 MOUNTAIRE FARMS INC WASTEWATER TREATMENT SYSTEM UPGRADE LUMBER BRIDGE, NORTH CAROLINA EFFLUENT PIPE PLAN AND PROFILE STA. 4+00 TO 9+00 131KEG A DATE: APRIL 2018 DRAWN BY: JKS DWG SCALE: 1" = 20' CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT WWW.cecinc.com SHEET OF 5 4 3 2 1 8 7 6 5 4 3 2 1 ICI -- ©M FI NIIIIIIIIIIIIIIII n� Cl I� IIIIIIIII, 0 NORTH i 21 REVISION RECORD ';<Wsj,tt';'•^, `ter NO DATE DESCRIPTION 08/16/2018 REVISED DAF NOTE el"Int 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE i pps 5 04/01/2019 ISSUED FOR CONSTRUCTION L •. '�^ i�° 7 i `-.`;;'' cam.. ¢4" /4\ 08/08/2019 AS -BUILT 1 1 0 � 0 IIIIIIIIIIIIIIIIN �n IIIIIIIII, I� 5 0 5 10 AS BUILT DRAWING NO.: LA AV AV TREATMENT BUILDING MOUNTAIRE FARMS, INC PROCESS MODIFICATIONS hhhhh' FRAZER, PENNSYLVANIA / NC Firm License # C-3035 WASTEWATER TREATMENT EXISTING BUILDING CONDITIONS 200 (610) 407-4100 KEG I . NET Civil & Environmental Consultants, Inc. SYSTEM UPGRADE Keystone DATE: APRIL 2018 DRAWN BY: JKS A NC FIRM LICENSE 1900 Center Park Drive - Suite A - Charlotte, NC 28217 DWG SCALE: 3/16" = CHECKED BY: GPT/MDW #C-4604 LUMBER BRIDGE, NORTH CAROLINA ENGINEERING GROUP Ph: 980.237.0373 •Fax: 980.237.0372 PROJECT No: 174-540 WWW.cecinc.com APPROVED BY: GPT SHEET OF 6 5 4 3 2 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 ©w o. N. o. [am om NORTH 1 21 4,:aia,'<'aV� REVISION RECORD NO DATE DESCRIPTION 08/16/2018 REVISED NEW DAF NOTE FRAZER, PENNSYLVANIA Q 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE p Ham•, c, M 610 407 -410 0 3 04/01/2019 ISSUED FOR CONSTRUCTION K E G I. N E T Q 08/08/2019 AS-BUI LTS Ke stone NC FIRM LICENSE y #C-4604 p 4+/d zlo ENGINEERING G R O U P F7 6 5 NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com EXISTING DAF POWER AND CONTROLS SCALE: 3/16" = 1'-0" I I m 1 7 5 0 5 10 MOUNTAIRE FARMS, INC WASTEWATER TREATMENT SYSTEM UPGRADE DATE: LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: PROJECT NO: APPROVED BY: 3 2 TREATMENT BUILDING PROCESS MODIFICATIONS DEMOLITION PLAN APRIL 2018 1 DRAWN BY: 3/16" = V-0-1 CHECKED BY: AS BUILT DRAWING NO.: 201 JKS GPT/MDW 174-540 GPT SHEET OF 1 MCI I■o .o M14 .o min mo 5 1 NORTH 0 1 EX/STING 3/41� STEEL SCH 40 AIR SUPPLY TO FEED FORWARD G PUMP STA TION V- C.O. II EXIS I G CHEM/CAL L PALM J I ARrEAORAGE FD i I I I JI L_ I —�IL —J II III EXISTING CATCH BASIN II II I II I I II III I III I I I I II II III F III II I I FE II I II i I f i FD EXISTING 610 RAW WATER LINE FROM FEED FORWARD PUMP BUILDING TO EXISTING DAF I I l � ------� - -II-----I --- / I I - EXISTING 61� RAW WATER LINE FROM FEED FORWARD PUMP BUILDING TO EXISTING DAF '$" E EXISTING 1 "0 PVC SCH 40 WATER LINE TO FEED / FORWARD PUMP STATION / DISCONNECT EXISTING SLUDGE CONVEYOR. INSTALL NEW 4"0 Il EXISTING 121� PVC SOR 35 / / �y SCH 40 PVC SLUDGE PIPING I STORM DRAIN TO NEW SLUDGE PUMP. FIELD LOCATED PUMP AND PIPING. FD --4 - / 0 D �- ------------- T - - - I " NEW 3 PVC XISTING PUMP STAT/ON E SLUDGE DISCHARGE TO EXISTING TRUCK LOADING AREA 01 EXISTING TRUCK PAD NEW 2"x4" REDUCER EXISTING 12'� PVC SDR 26 DRAIN HEADER NEW SLUDGE PUMPS C I o_ 0 _ 1 0 1 EX/STING EX/STING POL YMER POL YMER l EX/STING TANK TANK I POL YMER TANK I II 0° UNIT B EXISTING EXISTING III EXISTING UNIT A UNIT 5 FEED PUMP FEED PUMPS FD I i FEED PUMI JI ---- -EE--------- II EXISTING 1215 DAF EFFLUENT HEADER MD O MD MD EXISTING 0 DAF UNIT - A O O IIIIIIIIII� �"�IIGai�' FD I 11 II C DAF UNIT - 8 XD 0 \ 0 11 TD I O I' E fi 0 0 EXISTING WORLD WATERWORKS DAF NEW 2"0" REDUCER III EXISTING ELECTR/CAL ROOM FE EXISTING BLOWER ROOM EXISTING 2 "0 SCH 80 PVC - WATER LINE �I r 1 I EX1SANG MANHOLE TO BE REMOVED I I / EXISTING 16 "0 PVC DR 35 CLARIFIER EFFLUENT TO s=� / AERATED STORAGE BASIN I I /III A ' I I I I III lul I NEW 18"0 C900 PVC OVERFLOW LINE FROM MBBR REACTOR TANKS \ A FIELD LOCATE NEW POLYMER PUMPS & TIE-IN TO —1-1 EXISTING POLYMER FEED. ROUTE LINE TO NEW FLOC TUBE. MOUNT PUMP ON 12" EXISTING PAD. I I TRANSFER I I PUMPS NEW 16"00" C900 ® PVC REDUCER Ilk _j T/ " NEW 16 0 C900 PVC DISCHARGE EXISTING 12,10 DAF I EXISTING 610 I / / LINE TO NEW MBBR REACTOR TANKS EFFLUENT HEADER I I Q1K EXISTING EXISTING PVC SDR 26 �/ EXISTING 12 "0 D. 1.FLIED FEED 7 F - _ _I PUMPS_— I �pi17D� I ] CLARIFIER DRAIN �/ BLOCK CAP AND THRUST / INSTALL NEW 10" VALVE u f / INSTALL NEW 10" TEE IN THE VERTICAL LINE 0 EXISTING SEAL / / I I AND VALVE. COORDINATE - - - - - - - - - _ WATER PUMPS I I TIE-IN WITH OWNER --------- --- - (ABANDONED) FIELD INSTALL EXISTING w �,� _ 1 "0 LINE. LOCATE /N ' / / I I THE FIELD 7 I � / NEW 12" 0 S.S. EXISTING 610 INFLUENT > EFFLUENT LINE TO SORIN DAF "C" DISCHARGE LINE will V/- in ._ Vi I� FD mills _ it-__=_ r 1 'NNI ✓, A, i= EXISTING CLARIFIER � La' / III IN VERTICAL I i -= F� >�, NEW 3"0 SCH 80 PVC ll -- - ----- - - - ---- _- - - ---- / / 1 TO FRAC TANKS 231 II i L EXISTING 4 "0 PVC SDI?2 5 WATER SERVICE ��Il I NEW 6"x10" REDUCER I" II EXISTING 610 RAW WATER I I r LEI Im t INFLUENT LINE TO EXISTING -\ 05 I 1 DAF „C _ I NEW 6"0 RAW WATER II NEW 18"00" REDUCER INFLUENT LINE TO NEW DAF "D" II NEW 18"08"x10" TEE -------------------- 0421 17 44 °��Prreraece�er+' NEW 6 FLOW METER IN VERTICAL TIE-IN NEW 6"0 INFLUENT LINE TO DAF 1 231 EXISTING WORKS WA TER WORKS DAF INFLUENT LINE (TO BE ABANDONED) 18"0 C900 PVC LINE FROM MBBR REACTOR TANKS TO - - - EXISTING WORLD WATER WORKS DAF iI- - - - - - - - - - N J - TT_ ------------------------------------- MOUNTAIRE FARMS, INC 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE FRAZER, PENNSYLVANIA 04/01 /2019 ISSUED FOR CONSTRUCTION (6 10) 4 0 7 -410 0 INC Firm License # C-3035 WASTEWATER TREATMENT �q 04/04/2019 ADDED FLOOR DRAINS AND RELOCATED SLUDGE DISCHARGE KEGLNET Civil &Environmental Consultants, Inc. SYSTEM UPGRADE KeystoneATE: 08/08/2019 AS -BUILT NC FIRM LICENSE 1900 Center Park Drive - Suite A -Charlotte, INCNC 28217 DWG SCALE: #C-4604 LUMBER BRIDGE, NORTH CAROLINA ENGINEERING G R O U P Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: www.cecinc.com APPROVED BY: 7 6 5 4 3 2 11 II INSTALL NEW 18" ISOLATION VALVE I I 'FrE VISION RECORD NO DATE DESCRIPTION 09/05/2018 REVISED NEW NOTES E I 0 _© _o MIN _n _ 0 r� o AS BUILT SCALE IN FEET 0 8 16 DRAWING NO.: TREATMENT BUILDING PROCESS MODIFICATIONS EQUIPMENT LAYOUT 230 APRIL 2018 1 DRAWN BY: JKS A 1/8" = V-0" ICHECKED BY: GPT/MDW 174-540 GPT SHEET OF 1 ©al 1 0 1 0 1 AS 1 0 1 1 1 0 I M© a In L\ 0 12" DIA. PVC DR 3. STORM DRAIN CONCRETE ENCASEM 6" MINIMUM UNDER FOOTER (TYPICAL) C I I NEW 18"0 LINE N FROM MBBR REACTOR TANKS T/FLOOR EL. 199.0, 12'-6" 12" 0 S.S. EFFLUENT DISCHARGE LINE O PROPOSED WATER WORKS DAF 12" 0 S.S. EFFLUENT DISCHARGE LINE B NEW 6"0 INFLUENT LINE FROM PUMP HOUSE 0 v�FF°z: 4,:aia,'<AaV� REVISION RECORD A3 -� NO DATE DESCRIPTION 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION 04/04/2019 RELOCATED SLUDGE DISCHARGE V.: �•e,�, 19 4„S_ ;. pay 08/08/2019 AS -BUILT A /Z")/ p 8 7 SECTION 1 SCALE : 1 /8" = V-0" 230 NEW 3" 0 S.S. SLUDGE DISCHARGE FROM NEW WORLD WATERWORKS DAF. DISCHARGE INTO EXISTING SOLIDS DISCHARGE TO TRUCK LOADING AREA 0 CA TONIC TRANSFER 4 TANK ANIONIC MIX TANK EXISTING DRAIN CONDITION UNKNOWN' SECTION 2 SCALE 3/16" = V-0" 230 n EXISTING 3" DIA. DIFJ DAF - C DRAIN EXISTING 6" DIA. PVC DWV DAF DRAIN SLOPE TO FLOOR DRAIN FRAZER, PENNSYLVANIA (610) 407-4100 Keystone KEGI .NET NC FIRM LICENSE ENGINEERING GROUP #C-4604 6 5 HYDRAULIC SCRAPER EXISTING DAF UNIT - C 12" DIA. PVC SCH 80 OFF GASSING FEED LINE MIX CHAMBER B CONDITIONER AV NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com NEW WORLD WATER WORKS DAF T/FL 199.0 0 A AL) )N SUCTION (TYPICAL) SECTION 3 SCALE 1 /8" = V-0" 230 Ivr_vv o w iNFLUEI\ LINE FROM PUMP HOUSE AS BUILT SCALE IN FEET AS BUILT MOUNTAIRE FARMS, INC WASTEWATER TREATMENT SYSTEM UPGRADE DATE: LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: PROJECT NO: APPROVED BY: 3 2 W 0 �n ■o 0 8 16 DRAWING NO.: TREATMENT BUILDING PROCESS MODIFICATIONS SECTIONS 231 APRIL 2018 DRAWN BY: JKS A 1/8" = V-0" CHECKED BY: GPT/MDW 174-540 GPT SHEET OF 1 8 7 6 5 4 3 2 1 1112.1� IF 1� � 0� CI IO IIIIIIIII� T/ GROUND CONCR TANK I i 0 ID rVVfrCbHIr- VHLVr- IV Y/ VJVV 1 YV LIILVLIYI VVlY \LIL LINE TO WORLD WATER TANK PAD WORKS DAF (T-6201) A —A SECTION 102 VALVE IL W J.J. AIM M/F\IVIr VLv -- -- -- - - - -- - ---- -- ••-• ---.•. _..-- B—B SECTION 102 ` REVISION RECORD S,K NO DATE DESCRIPTION FC j << 04/01/2019 ISSUED FOR CONSTRUCTION 08/08/2019 AS -BUILT p 1 L L blo/ J 7 `t JV`t J.J. PRESSURE TRANSDUCER PORT L C I, 7„ OVERFLOW LINE (C—C SECTION 102 VVI `1 V1\L I L TANK PAD "'M ^ ^LET CONNECTION 3REAK 3" 0 PIPE) 1 MBBR INFLUENT PIPE DETAIL 232 SCALE: 3/16" = V-0" 1)0 S.S. PIPE 1)0 x72" INFLUENT REEN JW MOUNTAIRE FARMS INC PROPOSED MBBR TANK LAYOUT FRAZER, PENNSYLVANIA SECTIONS AS BUILT DRAWING NO.: I IF �IJ �0 IC IIIIIIIII� 113 (610) 407-4100 NC Firm License # C-3035 WASTEWATER TREATMENT 232 KEG I . NET Civil & Environmental Consultants, Inc. SYSTEM UPGRADE RAD E Ke StO � e DATE: APRIL 2018 DRAWN BY: JKS A Y INI C FIRM M LICENSE 1900 Center Park Drive - Suite A - Charlotte, NC 28217 LUMBER BRIDGE, NORTH CARD LI NA DWG SCALE: 1 /8"=11_011 CHECKED BY: GPT/MDW ENGINEERING GROUP Ph: 980.237.0373 •Fax: 980.237.0372 PROJECT No: 174-540 www.cecinc.COm APPROVED BY: GPT SHEET OF 5 4 3 2 1 8 7 6 5 4 3 2 1 ©_ 1© I_ 0_ ©_ n_ 0_ 0_ o_ NORTH 1 21 C 16, 4" PRESSURE TRANSDUCER 180° N-4 16" 0 SCREEI MANIFOLD 30" SIDE MANWAY —/ MANIFOLD CONNECTION 270° N-9 N-3 REVISION RECORD NO DATE DESCRIPTION 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE pl� 2 04/01/2019 ISSUED FOR CONSTRUCTION yf 08/08/2019 AS -BUILT J .Z 9 7 N ERFLOW DRAIN FRAZER, PENNSYLVANIA (610) 407-4100 Keystone KEG I .NET NC FIRM LICENSE ENGINEERING GROUP #C-4604 6 1 5 53'-7" ELEVATION MBBR MBBR No. 1 NOZZLE SCHEDULE (T-5201) MARK SIZE TYPE MATERIAL DESCRIPTION ORIENTATION ELEVATION REMARKS N-1 16" 150 Ib FF 304 S.S. INFLUENT 135° 231.25 DOUBLE FLANGE N-2 18" 150 Ib FF 304 S.S. OVERFLOW 315° 229.94 0 N-3 16" 150 Ib FF 304 S.S. FUTURE MANIFOLD 270° 225.67 DOUBLE FLANGE N-4 18" 150 Ib FF 304 S.S. SCREEN MANIFOLD 180° 225.67 DOUBLE FLANGE N-5 16" 150 Ib FF 304 S.S. SCREEN MANIFOLD 225° 225.67 DOUBLE FLANGE N-6 8" 150 Ib FF 304 S.S. DRAIN 315° 199.00 DOUBLE FLANGE w/SYPHON N-7 10" 150 Ib FF 304 S.S. FUTURE RAS 67.5° 231.25 N-8 4" 150 Ib FF 304 S.S. PRESSURE TRANSDUCER 167.5° 199.00 DOUBLE FLANGE N-9 30" 150 Ib FF 304 S.S. SIDE MANWAY 270° 199.50 DOUBLE FLANGE NOTES: 1. FLOOR TO BE FURNISHED BY TANK MANUFACTURER TO MATCH TANK. TANK TO BE 304 STAINLESS STEEL OR ENGINEER APPROVED EQUAL. 2. TANK FOUNDATION DESIGN BY TANK MANUFACTURER. DESIGN TO BE SEALED BY NORTH CAROLINA PROFESSIONAL ENGINEER. AS BUILT MOUNTAIRE FARMS, INC NC Firm License C-303 WASTEWATER TREATMENT Civil & Environmental Consultants, Inc. SYSTEM UPGRADE DATE: 1900 Center Park Drive - Suite A - Charlotte, NC 28217 LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: WWW.cecinc.com APPROVED BY: 4 3 2 F I_ _0 FBI _0 _0 SCALE: 3/16" = 1'-0" 5 0 5 10 DRAWING NO.: MBBR TANK No. 1 PLANS & ELEVATIONS APRIL 2018 DRAWN BY: 3/16" = V-0" CHECKED BY: 271 JKS GPT/MDW 174-540 GPT SHEET OF 1 _o 7 1 6 5 4 1 3 1 2 1 1 ©= om ©m n� om 0� om NORTH I 21 180° N-3 18"0 SCREEN MANIFOLD MANIFOLD CONNECTION 270° \\\-- 30" O SIDE MANWAY N-5 N-10 PLAN VIEW REVISION RECORD 4,:aia,'<'aV° ``.�'`<at'f15;'•^•`ter NO DATE DESCRIPTION 01/11/2019 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION M� 3 08/08/2019 AS -BUILT ■ 1 0 6 INFLUENT 1 4" PRESSURE TRANSDUCER 0° N-7 18" O FEED LINE FROM MBBR No. 1 FLOW DRAIN 53'-7" ELEVATION MBBR No. 2 NOZZLE SCHEDULE (T-5202) MARK SIZE TYPE MATERIAL DESCRIPTION ORIENTATION ELEVATION REMARKS N-1 16" 150 Ib FF 304 S.S. INFLUENT 45° 229.94 ,& DOUBLE FLANGE N-2 18" 150 Ib FF 304 S.S. OVERFLOW 315° 229.94 N-3 18" 150 Ib FF 304 S.S. SCREEN MANIFOLD 180° 226.625 DOUBLE FLANGE N-4 18" 150 Ib FF 304 S.S. SCREEN MANIFOLD 225° 226.625 DOUBLE FLANGE N-5 18" 150 Ib FF 304 S.S. FUTURE MANIFOLD 270° 226.625 DOUBLE FLANGE N-6 8" 150 Ib FF 304 S.S. DRAIN 315° 199.00 DOUBLE FLANGE w/SYPHON N-7 16" 150 Ib FF 304 S.S. INFLUENT 0° 225.67 DOUBLE FLANGE N-8 10" 150 Ib FF 304 S.S. FUTURE RAS 67.5° 131.25 DOUBLE FLANGE N-9 4" 150 Ib FF 304 S.S. PRESSURE TRANSDUCER 22.5° 199.00 N-10 30" 150 Ib FF 304 S.S. SIDE MANWAY 270° 199.50 AS BUILT MOUNTAIRE FARMS, INC FRAZER, PENNSYLVANIAjXAF AF SAW (610) 407-4100 NC Firm License # C-3035 WASTEWATER TREATMENT KEGI.NET Civil & Environmental Consultants, Inc. SYSTEM UPGRADE Keystone DATE: #C-41604 LICENSE 1900 Center Park Drive - suite A -Charlotte, NC 28217 LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: ENGINEERING G R O U P Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: www.cecinc.com APPROVED BY: 6 5 4 3 2 III i F m© Mn NOTES: 1. FLOOR TO BE FURNISHED BY TANK MANUFACTURER TO MATCH TANK. TANK TO BE 304 STAINLESS STEEL OR ENGINEER APPROVED EQUAL. 2. TANK FOUNDATION DESIGN BY TANK MANUFACTURER. DESIGN TO SEALED BY NORTH CAROLINA PROFESSIONAL ENGINEER. mo Al SCALE: 3/16" = 1'-0" 5 0 5 10 DRAWING NO.: MBBR TANK No. 2 PLANS & ELEVATIONS APRIL 2018 DRAWN BY: 3/16" = V-0-1 CHECKED BY: JKS GPT/MDW 174-540 GPT SHEET 1 min 272 I, OF 8 7 0 5 4 3 2 1 ©1 01 ©1 FBI DI 0� o, SEE ' -------'SEE 0 TABLEA14' O TABLE� - I 2 f�'11�»MIN. c� c� GRADE I GRADE CV DOW ELLS ^ w I I o N I n w M o � I ' 3'-00lISQ. #4 @ 12" FOR 6" & LARGER LINES FOR 4" & SMALLER LINES PIPE SUPPORT FOOTINGS Yx4"0/4" ♦� (TYP.) X Q A 4'-010 MAX. II II Z4"x4N3/8" II II r/-W8x 17 16"x 16"x 1 /2" R (SEE DETAIL # 1) \-EXISTING-/ STRUCTURAL STEEL OR CONCRETE DETAIL NO.1 BASE & SUPPORT PLATES 44" 71(TYP.) 1 14" ill ) ( i(TYP. 5/8" ANCHOR BOLTS (TYP.) (TYP.) 1" ANCHOR BOLTS (TYP.) 1 /2" ANCHOR BOLTS --- & 3/4" DIA. HOLES & 1 1 /8" DIA. HOLES & 5/8' DIA. HOLES (4 PLACES) (4 PLACES) (2 PLACES) I — I _—_------ 6"x6"x1 /2" 10"x1 ON /2" BASE PLATE BASE PLATE 94»-1 4» 14" (TYP) (TYP.) I r (TYP. 7/8" ANCHOR BOLTS (TYP.) I 7/8" ANCHOR BOLTS - — - — - & 1 " DIA. HOLES _ & 1 " DIA. HOLES (4 PLACES) (4 PLACES) 12"x 12"x 1 /2" 16"x 16"x 1 /2" SUPPORT PLATE SUPPORT PLATE 5° X*.1 A A 18" MIN U 0 J SECTION X—X PLAN & SECTION THRUST BLOCK DETAILS f P 20"x20"x 1 /2" SUPPORT PLATE N. REVISION RECORD NO DATE DESCRIPTION 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE 04/01/2019 ISSUED FOR CONSTRUCTION �\ 08/08/2019 AS -BUILT 7 PIPE SUPPORT DETAILS N.T.S. TABLE #7 PIPE SIZE STEEL SECTION "M" 8" W5x16x9"LG. 416" 10" W5x16x9"LG. 416" 12" W6x2Ox9"LG. 45" 14" W6x24x9"LG. 5" 16" W6x24x9"LG. 416„ 18" W1Ox19x9"LG. 516" 20" W12x19x9"LG. 54" 24" W 14x3Ox9 "LG. 511 s" MAXIMUM STAINLESS STEEL PIPE SUPPORT SPACING (SCH.1 OS)200°F. NOTE: THIS TABLE IS BASED ON A MAXIMUM 1/8" DEFLECTION A MAXIMUM SPECIFIC GRAVITY OF 1.2 1" 1 2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" PIPE SPAN UNINSULATED 5'-6" 10'-0" 1 1'-0" 13'-0' 14'-6" 16'-0" 18'-0" 20'-0' 21'-0' 22'-0' 22'-0' 221-01123'-0" 23'-0' PIPE SPAN INSULATED 6'-0" 7'-0" 7'-6" 9'-6" 10'-6" 12'-0" 13'-0" 14'-6' 15'-6" 15'-6" 16'-0' 16'-6" 17'-6" 18'-0" NOTE: FOR LINED PIPE, PVC, OR FIBERGLASS SUPPORT SPACING SHALL BE AS PER MANUFACTURER'S SPECIFICATIONS. SIZE 90° BENDS 45° BENDS 22.5° BENDS TEES PLUGS A B A B A B A B C D 8" 22" 13" 12" 13" 8" 10" 13" 16" 12" 29" 18" 39" 33" 24" 30" 13" 27" 26" 35" 24" 58" FRAZER, PENNSYLVANIA (610) 407-4100 Keystone NC F I ET NC FIRM LICENSE ENGINEERING GROUP #C-4604 6 5 NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 " Fax: 980.237.0372 www.cecinc.com #5 © 12" EACH MIN. 4" FROM E r� E "EW CONCRETE PAVEMENT =PTH EQUAL TO EXISTING AVEMENT DEPTH VEMENT TO BE SAWED OR ATLY CUT PERPENDICULAR SURFACE. ROUGHEN ISTING CONCRETE FACE. —MIN. 3/4" EXISTING BASE NEW CABC BASE DEPTH EQUAL TO EXISTING DEPTH 6" MIN. 12" SCREENED GRAVEL OR CROWNED STONE SUBBASE BACKFILL (SEE NOTE 'VC SEWER PIPE ,SEE NOTE 4) CREENED GRAVEL OR RUSHED STONE EDDING. SEE NOTE 4 SEWER PIPE TRENCH AND PAVEMENT REPAIR DETAIL (CONCRETE PAVEMENT) N.T.S. 1. BACKFILL EXCAVATED AREAS WITH CRUSHED STONE UNLESS OTHERWISE NOTED. THE BACKFILL SHALL BE MADE IN 6" LAYERS AND SHALL BE COMPACTED TO AT LEAST 95% OF STANDARD DENSITY (AASHO METHOD T-99). EACH LAYER MUST BE THOROUGHLY TAMPED BY A MECHANICAL TAMP BEFORE THE NEXT LAYER IS PLACED. ALL CONCRETE PAVEMENT REPLACED SHALL MATCH EXISTING. BASE COURSE DENSITY AND SUBGRADE DENSITY SHALL BE 100%. BACKFILL SHALL BE CABC OR CONCRETE SLURRY. SEE PIPE TRENCH AND PAVEMENT REPAIR DETAIL. 2. PROVIDE MINIMUM OF 6" OF CRUSHED STONE BENEATH FOUNDATIONS AND SLABS FOR ALL STRUCTURES UNLESS OTHERWISE NOTED. 3. SEAL PIPE PENETRATIONS WITH CALPICO OR THUNDERLINE LINK SEAL EXPANDING SEAL. SEAL TO BE EPDM WITH S.S. BOLTS. 4. PIPING TO BE BEDDED WITH 1 /2" MAX. CRUSHED ROCK CONFORMING TO CABC OR GROUT, CONCRETE SLURRY OR EQUAL. 5. USE 3000 psi CONCRETE FOR SLAB REPAIR UNLESS OTHERWISE SPECIFIED BY OWNER. REBAR TO BE GRADE 60 STEEL. AS BUILT MOUNTAIRE FARMS, INC WASTEWATER TREATMENT SYSTEM UPGRADE DATE: LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: PROJECT NO: APPROVED BY: 3 2 FAI MISCELLANEOUS DETAILS APRIL 2018 DRAWN BY: NTS CHECKED BY: DRAWING NO.: 280 JKS GPT/MDW 174-540 GPT SHEET OF 1 I:1 G 10 E FBI C 13 A H 0 II 6 1 5 4 1 3 2 1 H G F E L91 C 0 A Q TYPE ONE PIPE SUPPORT APPLIES TO AN 18" DIAMETER WELDED STAINLESS STEEL PIPE WITH A 45' BEND AND A MAXIMUM THRUST OF 1,150 POUNDS. THE SUPPORT IS TO BE POSITIONED PERPENDICULAR TO THE PIPE AT THE 45' BEND 18" DIAMETER STAINLESS STEEL PIPE WITH 45` BEND PIER IFOOTING I I 1 PLAN - TYPE 1 PIPE SU 281 SCALE: 1/2"=1'-0" 18" DIAMETER STAINLESS STEEL PIPE WITH 90` BEND PIER J I I FOOTING CDCDTHRUST I I 5 � � �81 L I L TYPE TWO PIPE SUPPORT APPLIES TO AN 18" DIAMETER WELDED STAINLESS STEEL PIPE WITH A 90' BEND AND A MAXIMUM THRUST OF 2,125 POUNDS. THE SUPPORT IS TO BE POSITIONED PERPENDICULAR TO THE PIPE AT THE 90" BEND 5-0" PPORT 2 PLAN - TYPE 2 PIPE SUPPORT 281 SCALE: 1/2"=1'-0" 4 n22 nI A\Ar Trn C"rA lA 11 rc-S END PIER 2» ACE TIES ® 12" SPACING ZADE SECTION - TYPE 1 PIPE SUPPORT SCALE: 1/2"=1'-0" � REVISION RECORD �N CAR O�••..•••••.��/ NO DATE DESCRIPTION ?Q�OF Ck9 1 02-26-19 REDESIGNED TYPE 1 PIPE SUPPORT AND ADDED GENERAL NOTES 85 7 _ A 02-26-2019 8 I 7 10 nI Al Arrrn C`rA IA 11 r c-s END PIER DE GRADE TIES ® 12" SPACING SECTION - TYPE 2 PIPE SUPPORT 18" DIAMETER STAINLESS STEEL PIPE WITH 90° BEND PIER IFOOTING CD I s l s I 6 THRUST 281 I I ICD J TYPE THREE PIPE SUPPORT APPLIES TO AN 18" DIAMETER WELDED STAINLESS STEEL PIPE WITH A 90' BEND AND A MAXIMUM THRUST OF 4,200 POUNDS. THE SUPPORT IS TO BE POSITIONED PERPENDICULAR TO THE PIPE AT THE 90" BEND 7'-0" _I PLAN - TYPE 3 PIPE SUPPORT SCALE: 1/2"=1'-0" 10 nI AAlrrrn c-rA lA 11 r c-s END PIER DE RADE TIES © 12" SPACING DTING �5 x 6'-6" IG SECTION - TYPE 3 PIPE SUPPORT SCALE: 1/2"=1'-0" 281 SCALE: 1/2"=1'-0" C 1LC WITU 9 011 Unnl,� THIS FACE TYPE 1 THIS FACE TYPES 2 AND 2—#5 WITH 6" HOOK THIS FACE SET OF 3—#3 TIES © 12" O.C. MAXIMUM SPACING 18" DIAMETER PIPE ABOVE PIER 5—#6 WITH 12" HOOK THIS FACE (TYPE 1) 5—#6 WITH 9" HOOK THIS FACE (TYPES 2 AND 3) 2—#5 WITH 6" j HOOK THIS FACE j SECTION - TYPICAL PIER SCALE: 1/2"=1'-0" G F E GENERAL NOTES: 1. THESE DRAWINGS SHALL BE USED IN CONJUNCTION WITH AND COORDINATED WITH ALL OTHER DRAWINGS AND CONTRACT DOCUMENTS. 2. ALL WORK SHALL COMPLY WITH THE 2012 EDITION OF THE NORTH CAROLINA STATE BUILDING CODE AND ALL LOCAL AND STATE CODES GOVERNING THIS PROJECT. 3. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND GRADE CONDITIONS, BOTH NEW AND EXISTING, PRIOR TO THE START OF ANY WORK. IN THE EVENT OF A DISCREPANCY BETWEEN THESE D STRUCTURAL DRAWINGS AND OTHER CONTRACT DOCUMENTS OR EXISTING FIELD CONDITIONS THAT PREVENTS THE EXECUTION OF THE WORK AS DEPICTED BY THESE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 4. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE AND PROTECT ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 5. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE STRUCTURAL INTEGRITY OF ALL ADJACENT STRUCTURES AND STRUCTURAL ELEMENTS DURING CONSTRUCTION. 6. FOUNDATION DESIGN IS BASED UPON A PRESUMPTIVE ALLOWABLE SOIL BEARING PRESSURE OF 3000 PSF. CONTRACTOR SHALL VERIFY THE ACTUAL ALLOWABLE SOIL BEARING PRESSURE PRIOR TO CONSTRUCTION. 7. FOUNDATION SOILS SHALL BE EXCAVATED TO THE LINES AND GRADES SHOWN ON THE DRAWINGS. 8. UTILITY LINES SHALL NOT BE PLACED THROUGH OR BENEATH FOUNDATIONS WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. C 9. THE MINIMUM 28 DAY COMPRESSIVE STRENGTH OF ALL POURED —IN —PLACE CONCRETE SHALL BE 4000 PSI UNLESS NOTED OTHERWISE ON THESE DRAWINGS. 10. CEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM C-150, TYPE I, UNLESS NOTED OTHERWISE. 11. CONCRETE SLUMP AT THE TIME OF PLACEMENT SHALL BE 4" +/— 1". 12. PLACEMENT OF CONCRETE INCLUDING SLUMP, MECHANICAL VIBRATION, AND CALCIUM CHLORIDE CONTENT SHALL BE IN ACCORDANCE WITH ACI 301. 13. REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615 GRADE 60. 14. CONCRETE COVER OVER REINFORCING STEEL SHALL CONFORM TO THE FOLLOWING UNLESS NOTED OTHERWISE. CONCRETE CAST AGAINST THE EARTH 3" FORMED CONCRETE EXPOSED TO THE EARTH 2" CONCRETE EXPOSED TO AIR 1" B BARRY LAMBERT ENGINEERING, PC Poof 956 M O U NTAI R E FARMS, I N C BsltrIa ,NNorth Carolina 28012 "17 IFAM FRAZER, PENNSYLVANIA plaa� (704) f♦t1�10l0 (610) 407-4100 WASTEWATER TREATMENT M UCM N& 0-117115 w RD= NIL I= KEG I . NET Civil &Environmental Consultants, Inc. SYSTEM UPGRADE DATE: JANUARY 2019 DRAWN BY: Ke stone 1900 Center Park Drive - Suite A - Charlotte, NC 28217 UMBE R BRIDGE, I D E NORTH AR LI N DWG SCALE: CHECKED BY: y U G O C O ENGIN EERING GROUP Ph: 980.237.0373 • Fax: 980.237.0372 PROJECT NO: WWW.cecinc.com APPROVED BY: 5 4 3 2 DRAWING NO.: 281 BOL DRAFT 174-540 DRAFT SHEET OF 37 1 G 0 II 5 4 1 3 2 1 H C F E L�7 C a A WF L3x3xj BRA 2'-0" THICK CONCRETE F( APPROXIMATE FOOTING PLAN NOTE: CONTRACTOR MAY WELD OR B( CONNECTIONS FOR BRACING ME IF WELDS ARE USED, THERE SE A MINIMUM OF 3" OF J" FILLEI ON EACH SIDE AT EACH END c BRACING MEMBER. IF BOLTS USED, THERE SHALL BE A MIN TWO 3/4" DIAMETER ASTM A BOLTS AT EACH END OF EACH BRACING MEMBER. L3x3xj BRACING T 2'-0" THICK CONCRETE F( APPROXIMATE C 3—#8's IN LINE COLUMNS SEE I #5© SIDE ELEVATION EDGE OF FOOTING 4-1" DIAMETER ANCHOR BOLTS AT EACH COLUMN ON AN 11 j"x11 4" GAGE WITH 6%311xO'-6" PLATE EMBEDDED A MINIMUM OF 12" DIRECTION OF TYPICAL REINFORCING STEEL BASE PLATE 15"x1 "x1'-3" ON 2" NONSHRINK GROUT 3—#8's TOP AND BOTTOM IN LINE WITH COLUMNS AS SHOWN W8x31 COLUMN TYPE 4 PIPE SUPPORT SCALE: 1/4'=1'-0' REVISION RECORD •..•••••. ,�/ NO DATE DESCRIPTION • 85 7 ; ���rrrlirr►��� 03-15-2019 8 I 7 6 '--2'-0" THICK CONCRETE FOOTING WITH TYPICAL REINFORCING #5's ® 12" O.C. TOP AND BOTTOM FOOTING PLAN Keystone ENGINEERING GROUP NI TH _AN W8x31 L3x3x3 BRACIN 2'-0" THICK CONCRETE F( APPROXIMATE A FOOTING PLAN W8x31 NOTE: CONTRACTOR MAY WELD OR BOLT CONNECTIONS FOR BRACING MEMBERS. IF WELDS ARE USED, THERE SHALL BE A MINIMUM OF 3" OF J" FILLET WELD ON EACH SIDE AT EACH END OF EACH BRACING MEMBER. IF BOLTS ARE USED, THERE SHALL BE A MINIMUM OF TWO 3/4" DIAMETER ASTM A 325 H.S. BOLTS AT EACH END OF EACH BRACING MEMBER. L3x3xj BRACING TYPICAL W8x31 2'-0" THICK CONCRETE FOOTING APPROXIMATE GRADE 3—#8's IN LINE WITH — COLUMNS SEE PLAN #5@12" O.C. " PLATE FOR CONNECTION OF W8 W8x31 8" THICK PLATE TYP. N I C' I z � #5®12" O.C. i N o z I � 8'-3j„ SIDE ELEVATION c 3—#8's IN LINE WITH COLUMNS SEE PLAN EDGE OF FOOTING 4-1" DIAMETER ANCHOR BOLTS AT EACH COLUMN ON AN 11 1"x11 1" GAGE WITH 6"xj"x0'-6" PLATE EMBEDDED A MINIMUM OF 12" DIRECTION OF TYPICAL REINFORCING STEEL BASE PLATE 15"x1 "x1'-3" ON 2" NONSHRINK GROUT 3—#8's TOP AND BOTTOM IN LINE WITH COLUMNS AS SHOWN 2'-0" THICK CONCRETE FOOTING WITH TYPICAL REINFORCING #5's W8x31 COLUMN ® 12" O.C. TOP AND BOTTOM I.' TYPE 5 PIPE SUPPORT SCALE: 1/4'=1'-0' GENERAL NOTES: 1. SEE SHEET 281 FOR GENERAL NOTES IN ADDITION TO THE FOLLOWING. 2. ALL STRUCTURAL ROLLED SHAPES SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF ASTM A 292. 3. ALL MISCELLANEOUS STRUCTURAL SHAPES SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF ASTM A 36. 4. ALL WELDING SHALL CONFORM TO AWS REQUIREMENTS FOR THE TYPE OF WELD BEING MADE. 5. ALL BOLTS SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF ASTM A 325 H.S. BOLTS. AFI, FjAF WIA FRAZER, PENNSYLVANIA JA (610) 407-4100 KEGI.NET Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com 5 4 MOUNTAIRE FARMS, INC WASTEWATER TREATMENT SYSTEM UPGRADE UMBER BRIDGE, NORTH CAROLI 3 FOOTING PLAN BARRY LAMBERT ENGINEERING, PC Poet Offlce Box 956 Belmont, North Carolina 28012 paa.g (� ett�oeo M UCM W o-ms w rwa= In ism DATE: MARCH 2O19 DRAWN BY: DWG SCALE: CHECKED BY: PROJECT NO: APPROVED BY: 2 DRAWING NO.: 282 BOL DRAFT 174-540 DRAFT SHEET 1 OF 37 H G F E C a 0 7 6 I 5 4 I 3 2 1 H C F E L�7 C 0 A 0 Cn w J 0 0 Of w z w U 0 w z w U 1j" DIAMETER HOLE 4-3/4" DIAMETER EPDXY ANCHORS WITH MINIMUM EMBEDMENT OF 6" 6 EQUAL SPACES = 13'-1121" DAF SUPPORT FRAME PLAN SCALE: 1/2"=1'-0" 15'-1" 7" 13'-112" 7" 1> 2j" I 1'-9jt, I 1'-9j" I 1'-9jt, I 1'-9j't I 1'-9jt, I 1'-9jt, I 1'-9j„ I 1, 21t' 4'-0" " THICK STIFFENER PLATE TYP. W12x65 + PLATE 9j%j%CONT. 4 DIAMETER PIPE BRACE TYP. WITH 1 PLATE EACH END WELDED TO FRAME IN BOTH DIRECTIONS AT ALL CORNERS 1 SAW CUT EXISTING CONCRETE FINISHED FLOOR /FLOOR SLAB FOR INSTALLATION ELEVATION -OF NEW FOOTING �\`FL�;; CA17o�/'�'' NO DATE ,' a Cyr9 85 7 - 03-26-2019 7 4'-0" x 4'-0" x 1'-3" CONCRETE FOOTING LONGITUDINAL SECTION SCALE: 1/2"=1'-0" REVISION RECORD DESCRIPTION 10'-1j" CENTER TO CENTER OF HOLES DAF BASE WALL BOTTOM OF DAF / 1 \-W12x19 \ ;, VIN 1 TIE BEAM \ I i 4-3/4" DIAMETER EPDXY 4" DIAMETER PIPE BRACE TYP. WITHANCHO S WI H MINIMUM PLATE EACH END WELDED TO FRAME BOTH DIRECTIONS AT ALL CORNERS 71. I" EXPANSION JOINT MATERIAL AROUND PERIMETER OF ALL FOOTINGS 4'-0" x 4'-0" x 1'-3" CONCRETE FOOTING 9'-93" CENTER TO CENTER OF BEAMS TRANSVERSE SECTION SCALE: 1/2"=1'-0" NOTES: 1. THE HEIGHT OF DAF SUPPORT FRAME IS 4'-11" AT THE LOWEST POINT. CONTRACTOR SHALL ACCOUNT FOR FLOOR SLOPE AND ADJUST THE HEIGHT AT THE HIGHEST POINT ACCORDINGLY SUCH THAT F THE TOP OF THE FRAME IS LEVEL. 2. SIZE AND LOCATION OF THE PUNCHED HOLES SHOWN WERE TAKEN FROM THE DAF SHOP DRAWING. CONTRACTOR SHALL BEAR THE RESPONSIBILITY OF COORDINATING THE PUNCHED HOLES IN THE BEAM AND PLATE WITH THE REQUIREMENTS OF THE DAF. BOTTOM OF DAF 3. CONTRACTOR SHALL SAW CUT EXISTING FLOOR SLAB TO INSTALL NEW FOOTINGS AND FINISH TOP OF NEW FOOTINGS TO MATCH SURROUNDING EXISTING SLAB. W12x19 TIE BEAM 4. INSTALL"' EXPANSION JOINT MATERIAL AROUND THE PERIMETER OF ALL NEW FOOTINGS. 'I I 4-3/4" DIAMETER ASTM A 325 H.S. BOLTS TYP. TS6x6xj WITH 11%j%O'-11" CAP PLATE F11"x4"xO'-11" BASE PLATE ON 1�" NONSHRINK GROUT 4-#5's EACH WAY Keystone ENGINEERING GROUP AV A JAW FRAZER, PENNSYLVANIA (610) 407-4100 KEGI.NET Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 •Fax: 980.237.0372 www.cecinc.com 5 4 PLATE 10"x2"xO'-5" WITH 2" LONG x T6" FILLET WELDS ON THE LONG SIDE AT EACH CORNER RETURNED 1" AROUND CORNER ON SHORT SIDE OF PLATE AND 3" LONG x J" FILLET WELDS AT CENTER OF PLATE ON EACH OF THE LONG SIDES TYPICAL AT EACH END OF EACH BRACE FOR A TOTAL OF 16 PLACES W12x65 + PLATE 9"x$"xCONT. 2" THICK STIFFENER PLATE TYP. 4-3/4" DIAMETER ASTM A 325 H.S. BOLTS TYP. - TS6x6xj WITH 11 %j%O'-11 " CAP PLATE -11%j%O'-11" BASE PLATE ON 12" NONSHRINK GROUT FINISHED FLOOR ELEVATION 4-#5's EACH WAY MOUNTAIRE FARMS, INC WASTEWATER TREATMENT SYSTEM UPGRADE UMBER BRIDGE, NORTH CAROLI 3 GENERAL NOTES: 1. THESE DRAWINGS SHALL BE USED IN CONJUNCTION WITH AND COORDINATED WITH ALL OTHER DRAWINGS AND CONTRACT DOCUMENTS. 2. ALL WORK SHALL COMPLY WITH THE 2012 EDITION OF THE NORTH CAROLINA STATE BUILDING CODE AND ALL LOCAL AND STATE CODES GOVERNING THIS PROJECT. 3. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND GRADE CONDITIONS, BOTH NEW AND EXISTING, PRIOR TO THE START OF ANY WORK. IN THE EVENT OF A DISCREPANCY BETWEEN THESE STRUCTURAL DRAWINGS AND OTHER CONTRACT DOCUMENTS OR EXISTING FIELD CONDITIONS THAT PREVENTS THE EXECUTION OF THE WORK AS DEPICTED BY THESE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 4. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE AND PROTECT ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 5. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE STRUCTURAL INTEGRITY OF ALL ADJACENT STRUCTURES AND STRUCTURAL ELEMENTS DURING CONSTRUCTION. 6. FOUNDATION DESIGN IS BASED UPON A PRESUMPTIVE ALLOWABLE SOIL BEARING PRESSURE OF 3000 PSF. CONTRACTOR SHALL VERIFY THE ACTUAL ALLOWABLE SOIL BEARING PRESSURE PRIOR TO CONSTRUCTION. 7. FOUNDATION SOILS SHALL BE EXCAVATED TO THE LINES AND GRADES SHOWN ON THE DRAWINGS. 8. UTILITY LINES SHALL NOT BE PLACED THROUGH OR BENEATH FOUNDATIONS WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. 9. ALL STRUCTURAL ROLLED SHAPES SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF ASTM A 292. 10. ALL STRUCTURAL TUBE SHAPES SHALL CONFORM TO ASTM A 500 GRADE B. 11. ALL STRUCTURAL PIPE SHAPES SHALL CONFORM TO ASTM A 53 TYPE S GRADE B. 12. ALL MISCELLANEOUS STRUCTURAL SHAPES SHALL CONFORM TO ASTM A 36. 13. ALL WELDING SHALL CONFORM TO AWS REQUIREMENTS FOR THE TYPE OF WELDING BEING MADE. 14. ALL BOLTS SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF ASTM A 325 H.S. BOLTS. 15. THE MINIMUM 28 DAY COMPRESSIVE STRENGTH OF ALL POURED -IN -PLACE CONCRETE SHALL BE 4000 PSI UNLESS NOTED OTHERWISE ON THESE DRAWINGS. 16. CEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM C-150, TYPE I, UNLESS NOTED OTHERWISE. 17. CONCRETE SLUMP AT THE TIME OF PLACEMENT SHALL BE 4" +/- 1". 18. PLACEMENT OF CONCRETE INCLUDING SLUMP, MECHANICAL VIBRATION, AND CALCIUM CHLORIDE CONTENT SHALL BE IN ACCORDANCE WITH ACI 301. 19. REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615 GRADE 60. 20. CONCRETE COVER OVER REINFORCING STEEL SHALL CONFORM TO THE FOLLOWING UNLESS NOTED OTHERWISE. CONCRETE CAST AGAINST THE EARTH 3" FORMED CONCRETE EXPOSED TO THE EARTH 2" CONCRETE EXPOSED TO AIR 1" BARRY LAMBERT ENGINEERING, PC Poet Offlce Box 956 Belmont, North Carolina 28012 paa.g (� ett�oeo M UCM NIX, 0-117115 w r�a= In ism DATE: MARCH 2O19 DRAWN BY: DWG SCALE: CHECKED BY: PROJECT NO: APPROVED BY: 2 DRAWING NO.: 283 BOL DRAFT 174-540 DRAFT SHEET 1 OF 37 H G F E C 0 6 1 5 1 4 a X / X EXISTING AERA TED / \ STORAGE LAGOON 10' WIDE NATURAL GAS EASEMENT NORTH _ 1 95.9 _ NEW UTILITY TRANSFORMER 196. 195 4 / // WITH METER X \\ X 95 \\\\\ `� --- / // / / PROPOSE (SEE DR/ 197 EXISTING UTILITY Al TRANSFORMER No. \\ \\\ X / \\ \ PROPOSED 16"0 GRAVITY _ _ \ I // 195.8 F \'DISCHARGE ' DISCHARGE LINE (SEE — �\ \�j O / \ MBBR \ DWG. 130) _ 0 0 //�\ No.2 / EXISTING f �_ SANITARY TREA TMENT / SYSTEM / \ ` \ f PROPOSED PLC • ;\ \\\\ (SEE NOTE 5) \\ 197.6 -� x \ \ \ i TATIVE LAGOON ` \ \ \ \ I EXISTING EQUALIZATION BASIN FEED FORWARD PUMP STATION (SEE SHT 202) \\ 1 f •f / • / / X / / REVISION RECORD NO DATE DESCRIPTION Q01/11/2018 REVIEW FOR CONSTRUCTION ISSUE A 04/01/2019 ISSUED FOR CONSTRUCTION EXISTING TREA TMENT BUILDING \ A SCALE IN FEET 0 40 80 FRAZER, PENNSYLVANIA (610) 407-4100 KEGI.NET KeystoneNC FIRM LICENSE ENGINEERING GROUP #C-4604 196.6 x CONTRACTOR POWER RESPONSIBILITIES: C1. PROVIDE TRENCHING AND INSTALL NEW SERVICE CONDUCTORS AND CONDUITS FROM THE NEW METER MOUNTED ON TRANSFORMER TO THE PROPOSED BLOWER BUILDING. ALL TRENCHING SHALL BE PER DUKE ENERGY REQUIREMENTS. TRENCHING WILL NEED TO BE COORDINATED WITH EXISTING UNDERGROUND UTILITIES. C2. PROVIDE CONCRETE PAD FOR TRANSFORMER PER DUKE ENERGY REQUIREMENTS. UTILITY POWER RESPONSIBILITIES: U1. PROVIDE AND INSTALL TRANSFORMER AND METER ON CONTRACTOR PREPARED PLAN. U2. MAKE ALL PRIMARY AND SECONDARY CONNECTIONS AT THE TRANSFORMER. GENERAL NOTES: 1. WORK SHALL BE PERFORMED AS REQUIRED BY APPLICABLE SECTIONS OF THE NATIONAL ELECTRIC CODE, LATEST EDITION, GOVERNING LOCAL CODES, LAWS AND/OR REGULATIONS. 2. CONTRACTOR SHALL IN A WORKMAN LIKE MANNER PROVIDE A COMPLETE OPERABLE SYSTEM. OUTLINE DESCRIPTION AND DIAGRAMMATIC REPRESENTATION OF SYSTEM OPERATION AND EQUIPMENT DOES NOT LIMIT CONTRACTOR LIABILITY FOR THE INSTALLATION OF A COMPLETE AND OPERABLE SYSTEM. 3. CONTRACTOR SHALL ACQUAINT HIMSELF/HERSELF WITH WORK SHOWN ON OTHER DRAWINGS FOR THE \� \ VARIOUS CONTRACTS OF THIS PROJECT IN ORDER TO COORDINATE HIS/HER INSTALLATION. x 4. CONTRACTOR SHALL PROVIDE SUBMITTALS FOR ALL EQUIPMENT SPECIFIED ON PLANS FOR APPROVAL BEFORE CONSTRUCTION BEGINS. Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A - Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com 5. PLC PANEL LOCATED IN OPERATOR OFFICE, 2ND FLOOR OF WWTP BUILDING ELECTRICAL NOTES: 1. EXCEPT WHERE INDICATED, INSTALL A SEPARATE EQUIPMENT GROUND CONDUCTOR IN ALL CONDUIT CONTAINING 120 VOLT OR GREATER WIRING. 2. UNLESS OTHERWISE NOTED, CONDUCTORS TO BE 2#12, 1 #12 GND —3/4" CONDUIT. 3. CONDUITS ABOVE FLOOR SHALL BE SECURELY FASTENED TO BUILDING STEEL OR EQUIPMENT. 4. PROVIDE NAMEPLATES FOR ALL EQUIPMENT AND INSTRUMENTS. PROVIDE PANEL SCHEDULE FOR ALL PANELS. 5. ALL CONDUIT SHOWN DIAGRAMMATICALLY. CONDUIT ROUTING/LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL AND OTHER EQUIPMENT ELEMENTS AS REQUIRED. 6. UNDERGROUND CONDUITS SHALL BE 1" MINIMUM, PVC COATED RIGID STEEL OR SCHEDULE 40 PVC ENCASED IN CONCRETE. OUTDOOR EXPOSED CONDUIT SHALL BE PVC COATED RIGID STEEL. INDOOR CONDUIT SHALL BE SCHEDULE 40 PVC. "L DRAWING NO.: MOUNTAIRE FARMS, INC ELECTRICAL SITE PLAN WASTEWATER TREATMENT 500 SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: 1" = 40' CHECKED BY: GPT/MDW PROJECT NO: 174-540 APPROVED BY: GPT 7 C 5 4 3 E 1 G F E 01 L A PROPOSED BLOWER BUILDING ELECTRICAL PLAN (BUILDING HEIGHT SHALL BE 10' MINIMUM) 0 1 2 3 4 5 1 /2" SCALE IN FEET _ A RI / // �O �OC • S • O •2 i a AL r; • 3 44 REVISION RECORD NO DATE DESCRIPTION /�/ 01/11/2018 REVIEW FOR CONSTRUCTION ISSUE /2T 04/01/2019 ISSUED FOR CONSTRUCTION 7 I U M I O O C3 14- w oo Q< w RUNNING SPEED CMD FAULT SPEED FDBK IN AUTO RUN CMD 0o Q< w RUNNING SPEED CMD FAULT SPEED FDBK IN AUTO RUN CMD NEW PLC (LOCATED IN EXISTING TREATMENT BUILDING) 0o Q< Q RUNNING SPEED CMD pH FAULT SPEED FDBK ORP IN AUTO RUN CMD LID a LID 0 00 I a 00 1 a ltz 00 O � O g N O � O N O � O(3 N U (3 N C3 N U N (3 N L5 N U N 30 30 VFD FE FE B-5403 BLOWER 30 30 MBBR #1 MBBR #2 -OW METER FLOW METER AT PUMP HP-01 A 4X, 30A, 208V ONNECT -6,8,10 PANEL LP1 VFD BLOWER B-5404 VFD BLOWER B-5405 Q Q< Q Q Q N N N N DO LEVEL pH DO TEMP I I IORP I TEMP 0 0 0 0 0 0 OPEN/ OPEN/ OPEN/ CLOSE CLOSE CLOSE CMD CMD CMD a o- o- a_ a I N ~ 0 N N ~ 0 N N N N N I N N I I N N I I N o I j 1 j 1 p — I 1 � g — oo N N N N L5 N U C3 N j j (3 C3 N U N U N U N W W \ \ J J \ M M M m m m m M �1 U U U U w LI_ LI_ LL- LL- � AIT � AIT � AIT � AIT 30 31 31 31 m m m m N LIT ° LIT N N M 531 N N M 31 S S S AE AE LE AE AE LE 30 31 531 31 31 31 MBBR #1 MBBR #1 PINCH MBBR #1 MBBR #2 MBBR #2 PINCH MBBR #2 SOLENOID MBBR #1 MBBR #2 pH/ORP DO/TEMP MBBR #1 LEVEL MBBR LEVEL DO/TEMP MVALV�2 LEVEL VALVE SOLENOID LVE D SOLENOID VALVE V-5401 V-5402 V-5120 V-5128 NTERCONNECTION DIAGRAM N.T.S. Type Manufacturer and Catalog Number Description Volts (Watts) Remarks A COLUMBIA LXEM 4' DUST & MOISTURE RESISTANT LED 120-277 LXEM4-30LW-RFA- FIXTURE; HIGH IMPACT ACRYLIC (47) EU GASKETED ENCLOSURE SUITABLE FOR DAMP LOCATIONS; LOW WATT OUTPUT 50°C J HUBBELL LNC LED WALL MOUNT LIGHTING KIT, DIE 120-277 LNC-9LU-4K-3-3 CAST ALUMINUM HOUSING, POWDER (22) GRAY FINISH LIGHTING FIXTURE SCHEDULE FRAZER, PENNSYLVANIA (610) 407-4100 Keystone NC FIRM ET NC FIRM LICENSE ENGINEERING GROUP #C-4604 6 5 NC Firm License # C-3035 Civil & Environmental Consultants, Inc. 1900 Center Park Drive - Suite A -Charlotte, NC 28217 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com F, 120/208 V. 3 PHASE 60HZ 4 WIRE LIGHTING PANEL LP1 SCHEDULE SERVICE C/B KVA 'Z A n n n n n40 n n n n n n n n n n B C N n n n n n n n n n n n n n n n YZ KVA C/B SERVICE INDOOR LIGHTING 20A 1 2 20A INDOOR RECEPTACLES OUTDOOR LIGHTING 20A 3 4 20A OUTDOOR RECEPTACLES SPARE 20A 5 6 30PA HEAT PUMP HP-01 FIT-5301 20A 7 8 FIT-5302 20A 9 10 AIT-5309 20A 11 12 20A AIT-5312 AIT-5310 20A 13 14 20A AIT-5313 SPARE 20A 15 16 20A LIT-5314 LIT-5311 20A 17 18 20A SPARE SPARE 20A 19 20 20A SPARE MBBR #1 SOLENOID, V-5120 20A 21 22 20A MBBR #2 SOLENOID, V-5128 B-5403 COOLING FAN 20A 23 24 20A B-5404 COOLING FAN B-5405 COOLING FAN 20A 25 26 20A SPARE SPARE 20A 27 28 20A SPARE SPARE 120AI 29 301 120AISPARE PANEL MTD: SURFACE TYPE: NQOD MANUFACTURER: SQUARE `D' MAIN LUGS: PANEL LOADING SCHEDULE MAIN BREAKER: 125A FEEDER ENTRY: PHASE WATTS (KW) FEEDER SIZE: ENCLOSURE: NEMA 1 A BRANCH BREAKERS GUTTERS: TOP BOTTOM B C NO. POLES AMPS. SIDES CONNECTED LOAD SPARE TOTAL LOAD o'.j LIGHTING PANEL `LP1' SCHEDULE PROPOSED MOUNTAIRE FARMS, INC BLOWER BUILDING ELECTRICAL PLAN, WASTEWATER TREATMENT SCHEDULES AND DETAILS SYSTEM UPGRADE DATE: APRIL 2018 DRAWN BY: JKS LUMBER BRIDGE, NORTH CAROLINA DWG SCALE: CHECKED BY: GPT/MDW PROJECT NO: APPROVED BY: 3 2 DRAWING NO.: 174-540 GPT SHEET 1 G F Mal ML 502 lA OF