HomeMy WebLinkAbout19951227 Ver 1_COMPLETE FILE_19951125State of North Carolina
Department of Environment,
Health and Natural Resources
Division of Environmental Management
James B. Hunt, Jr., Governor
Jonathan B. Howes, Secretary
A. Preston Howard, Jr., RE., Director
APPROVAL of 401 Water Quality Certification
Mr. Wayne Powell
Environmental Engineer
Glaxo Wellcome
P. O. box 1887
Greenville, N.C. 27835-1887
Dear Mr. Powell:
d0k
ED FE F1
November 27, 1995
Pitt County
DEM Project # 951227
FILE COPY
You have our approval to place fill material in wetlands and waters for the purpose of repairing a
washed-out NPDES discharge culvert near the intersection of US 13N/NC 11 and US 264, as you
described in your application dated 16 November 1995. After reviewing your application, we have
decided that this fill is covered by General Water Quality Certification Number 3026. This certification
allows you to use Nationwide Permit Number 3 when it is issued by the Corps of Engineers.
This approval is only valid for the purpose and design that you described in your application. If
you change your project, you must notify us and you may be required to send us a new application.
For this approval to be valid, you must follow the conditions listed in the attached certification. In
addition, you should get any other federal, state or local permits before you go ahead with your
project.
If you do not accept any of'the conditions of this certification, you may ask for an adjudicatory
hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing,
send a written petition which conforms to Chapter 150B of the North Carolina General Statutes to the
Office of Administrative Hearings, P.O. Box 27447, Raleigh, N.C. 276 1 1-7447. This certification and
its conditions are final and binding unless you ask for a hearing.
This letter completes the review of the Division of Environmental Management under Section 401
of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-1786.
Sincerely,
ton Howard, Jr. P
Attachment
cc: Wilmington District Corps of Engineers
Corps of Engineers Washington Field Office
Washington DEM Regional Office
Mr. John Domey
Central Files
951227.1tr
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post-consumer paper
Glaxo Wellcome
Glaxo Wellcome Inc.
Five Moore Drive, Research Triangle Park, NC 27709
Telephone: 919 248 2100
November 16, 1995
Mr. Henry Wicker
US Army Corps of Engineers
Washington Regulatory Field Office
P. O. Box 1000
Washington, NC 27889
Dear Mr. Wicker:
Thank you for taking the time to meet with me on November 1, 1995 to discuss the emergency
repair of a NPDES outfall structure located on Parker Creek. Please find attached an application
to perform the emergency repairs under a Nationwide Permit Number 3 (Maintenance).
If I may provide any additional information, please let me know.
Sincerely,
J. Wayne Vowel
Environmental Engineer
mbb
Attachment
Glaxo Wellcome
Glaxo Wellcome Inc.
Five Moore Drive, Research Triangle Park, NC 27709
Telephone: 919 298 2100
November 16, 1995
Water Quality Planning
Division of Environmental Management
NC Department of Environment,
Health and Natural Resources
P. O. Box 29535
Raleigh, NC 27626-0535
Attn: Mr. John Dorney
Dear Mr. Dorney:
NOV 2 1 1995
l NVIRUNMENIAL SCIENCES
Please find attached seven copies of a permit application to perform emergency repairs under a
Nationwide Permit Number 3 (Maintenance). If I may provide any additional information, please
let me know.
Sincerely,
J. Wayn Powell
Environmental Engineer
mbb
Attachments
d ...r i
DEM ID: ?J?)=A&ION ID:
Nationwide Permit Requested (Provide Nationwide Permit #): Nationwide Permit Number 3
JOINT FORM FOR
Nationwide permits that require notification to the Corps of Engineers
Nationwide permits that require application for Section 401 certification
WILMINGTON DISTRICT ENGINEER WATER QUALITY PLANNING
CORPS OF ENGINEERS DIVISION OF ENVIRONMENTAL MANACI?F------
DEPARTMENT OF THE ARMY NC DEPARTMENT OF ENVIRONMENTyE.'I
P.O. Box 1890 AND NATURAL RESOURCES
Wilmington, NC 28402-1890 P.O. Boy 29535 !' ,!
ATTN: CESAW-CO-E Raleigh, NC 27626-0535 I
Telephone (919) 251-4511 ATTN: MR. JOHN DORNEY
Telephone (919) 733-5083
WETLANDS U(Jj&
ONE (1) COPY OF THIS COMPLETED APPLICATION SHOULD BE SENT TO THE ORPSVOEjjj
SEVEN (7) COPIES SHOULD BE SENT TO THE N.C. DIVISION OF ENVIRONM AGEMENT.
PLEASE PRINT.
1. Owners Name: Glaxo Wellcome Inc.
2. Owners Address: P. 0. Box 1887 Greenville, North Carolina 27835'1887
3. Owners Phone Number (Home): (Work): (919) 707-2310
4. If Applicable: Agent's name or responsible corporate official, address, phone number:
Contact Wayne Powell, Environmental Safety
(919) 707-2310
5. Location of work (MUST ATTACH MAP). County: Pitt
Nearest Town or City:
Greenville
Specific Location (Include road numbers, landmarks, etc.): Near Intersection of US 13N/NC11 & US 264.
See attached map.
6. Name of Closest Stream/River: Parker Creek
7. River Basin:
Tar River
8. Is this project located in a watershed classified as Trout, SA, HQW, ORW, WS I, or WS H? YES [ ] NO [ ]
9. Have any Section 404 permits been previously requested for use on this property? YES [ ] NO 14
If yes, explain. None that we are aware of at this time.
10. Estimated total number of acres of waters of the U.S., including wetlands, located on project site:
Project will be performed in a manner as to have minimal impact on any wetlands
and water quality.
11. Number of acres of waters of the U.S., including wetlands, impacted by the proposed project:
Filled: N/A
Drained: NIA
Flooded:
N/A
Excavated: N/A
Total Impacted: N/A
.i
12. Description of proposed work (Attach PLANS-8 1/2" X 11" drawings only): Emergency repair of
washed-out NPDES discharge culvert.
13. Purpose of proposed work: See below.
14. State reasons why the applicant believes that this activity must be carried out in wetlands. Also, note measures
taken to minimize wetland impacts. Culvert must be repositioned at the creek's edge.
This is a maintenance/repair of an existing structure.
15. You are required to contact the U.S. Fish and Wildlife Service (USFWS) and/or National Marine Fisheries Service
(NMFS) regarding the presence or any Federally listed or proposed for listing endangered or threatened species or critical
habitat in the permit area that may be affected by the proposed project. Have you done so? YES[ ] NO [ ] N/A
RESPONSES FROM THE USFWS AND/OR NMFS SHOULD BE FORWARDED TO CORPS.
16. You are required to contact the State Historic Preservation Officer (SHPO) regarding the presence of historic
properties in the permit area which may be affected by the proposed project? Have you done so? YES [ ] NO [ ] N/A
RESPONSE FROM THE SHPO SHOULD BE FORWARDED TO CORPS.
17. Additional information required by DEM:
A. Wetland delineation map showing all wetlands, streams, and lakes on the property. N/A
B. If available, representative photograph of wetlands to be impacted by project. N/A
C. If delineation was performed by a consultant, include all data sheets relevant to the placement of the
delineation line. N/A
D. If a stormwater management plan is required for this project, attach copy. N/A
E. What is land use of surrounding property? Silvaculture
F. If applicable, what is proposed method of sewage disposal? N/A
Owner's Signature Date
13. The project is being undertaken to maintenance/repair a NPDES discharge point
into Parl.er Creek. The existing discharge culvert is undersized and will be
replacad with a larger culvert.
The cul•-ert has "washed-out" on one side and is creating an erosion problem.
The larger diameter culvert should also reduce erosion on the other side of
the extremely narrow creek.
us I ? / l
as
W. I r ?-?
'h, --
O c?
z?
O r
r
Z
Tj
r ?
rT-l -r3
z
0
O
n
2
F-T
N.C. HWY 11 B U.S. 13
? = CO
O rT)
J?
?o
Tj --C? O
rT?
a
O
n -{
O Z
r
? O n Qz
Or J
rT
rl-l
rT-l
T ?
???
r O ?
?C
? Z ?
r O
= O
v C:?
00
R1
a
O
n,
r
r,
r
O
a ?I
® F'dkhfRS CR E.? DRfDGR.: PRCJECr
LEW IS, MC,
Generc -on cctor -
Z
I II
i
I
I
I I
i
i
Til-I
p l
I, V
1.0 Function/Scope
The scope of this project includes:
1.1 Remove existing 42 inch RCP and replace with 48 inch RCP to
eliminate erosion against the creek embankment and reduce
water velocity.
1.2 Re-adjust and install existing wood deck with safety rail.
1.3 Dredge approximately 30 LF X 2 ft deep of the canal on the North
side of the 48 inch culvert to remove mounds of mud and sediment
restricting water flow.
1.4 Remove existing RipRap and install new RipRap with fabric in
dredged area.
1.5 Design and Install a salt treated bulk head on the north side of the
new 48 inch RCP.(See attached Sketch)
1.6 Fill and re-grade access road by the new 48 inch culvert. Fill
material must be soils classified SM or better and compacted in
accordance to Glaxo-Wellcome Co. Specifications.
HOWSCOPE-2-92