Loading...
HomeMy WebLinkAboutNCG551115_Inspection_20190819EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NCG551115 19/08/19 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 3425 Hebron Road 3425 Hebron Rd Hendersonville NC 287397765 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:00AM 19/08/19 19/02/06 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 11:45AM 19/08/19 20/10/31 Name, Address of Responsible Official/Title/Phone and Fax Number Barbara Hudson,3425 Hebron Rd Hendersonville NC 287397765//843-683-3473/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Self-Monitoring Program Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 6826B156-9C9B-4281-B529-6295C18BBE67 9/9/2019 9/9/2019 NPDES yr/mo/day 19/08/19 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On August 19, 2019, I (Daniel Boss) conducted an inspection of the wastewater treatment system at 3425 Hebron Rd. The wastewater treatment system appeared to well maintained. I met with Barbara Hudson, Ginnie and Jean-Paul Lebosse who are all owners of the system; and Coy Holden who is an employee of Envirolink. This inspection was conducted in part due to concern from a citizen about the state of this wastewater system. I didn't see any reason to suspect that this wastewater system was having any malfunction. The septic tanks have been pumped every two years. The most recent effluent sample results were compliant from October of 2018. This facility is currently maintained by Envirolink and Mr. Holden performs monthly visits. A log book is kept on site. On the day of the inspection, the log book was missing and no one could account for the disappearance except by theft. The owner's said they will keep the log book in a more secure location going forward. NCG551115 17 (Cont.) Page#2 DocuSign Envelope ID: 6826B156-9C9B-4281-B529-6295C18BBE67 Permit:NCG551115 Inspection Date:08/19/2019 Owner - Facility: Inspection Type: 3425 Hebron Road Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Tanks have been pumped every 2 years. The requirement is for the tanks to be pumped at least every 5 years. Comment: Sand Filters (Low rate)Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re-circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Page#3 DocuSign Envelope ID: 6826B156-9C9B-4281-B529-6295C18BBE67 Permit:NCG551115 Inspection Date:08/19/2019 Owner - Facility: Inspection Type: 3425 Hebron Road Compliance Evaluation Disinfection-Tablet Yes No NA NE Number of tubes in use?1 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use?1 Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? The effluent is being sampled yearly. The most recent sampling results were within the permit limits. Comment: Page#4 DocuSign Envelope ID: 6826B156-9C9B-4281-B529-6295C18BBE67