HomeMy WebLinkAboutNC0080691_NOV-2019-PC-0619_20190904ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director CERTIFIED MAIL #: 7018 0360 0002 2099 1871 RETURN RECEIPT REQUESTED Mr. Shannon V. Becker, President Aqua North Carolina, Inc. 202 Mackenan Court Cary, North Carolina 27511 Dear Mr. Becker: NORTH CAROLINA Environmental Quality 4 September 2019 Subject: Notice of Violation Compliance Evaluation Inspection Windemere WWTP NPDES Permit No. NCO080691 Iredell County Tracking #: NOV-2019-PC-0619 Enclosed is a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject facility on August 27, 2019, by Mr. Wes Bell of this Office. Please inform the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding a copy of the enclosed report. This report is being issued as a Notice of Violation (NOV) due to the failures to properly calibrate and maintain the flow meter which are violations of the subject NPDES Permit and North Carolina General Statute (G.S.) 143-215 as detailed in the Flow Measurement - Effluent Section of the attached report. Pursuant to G.S. 143-215.6A, a civil penalty of not more than twenty-five thousand dollars ($25,000.00) per violation, per day may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. Penalties may also be assessed for any damage to surface waters of the State that may result from the violations. It is requested that a written response be submitted to this Office by September 25, 2019, detailing the actions taken to address the above -noted violations. The response shall also include the actions taken (including copies of operator training SOPS, list of proper equipment, etc.) to ensure all future flow meter calibrations (at all WWTPs) will be properly calibrated and maintained. In responding, please address your comments to the attention of Mr. Wes Bell. D Q � North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 NORTH CAROLINA Da"MoM a enWmn�bl mwnq 704,663.1699 Mr. Shannon V. Becker 4 September 2019 Page Two The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192 or at wes.bellkncdenr.gov. Sincerely, DocuSigned by: A14CC681 AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosure: Inspection Report United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 15 1 3 I NCO080691 111 12 I 19/08/27 I17 18 I S I 19 I G I 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 2.0 70 71 [.. I 72 73 L_LJ74 751 I I I I I I I80 u Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 11:15AM 19/08/27 15/04/01 Windemere WWTP NCSR 1328 Heronwood Rd Exit Time/Date Permit Expiration Date Sherrills Ford INC 28673 12:40PM 19/08/27 20/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Ricky Dean Reynolds/ORC/785-307-0864/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Shannon V Becker,202 Mackenan Ct Cary NC 27511/President/919-653-5570/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Wes Bell MRO WQ//704-663-1699 Ext.2192/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger Division of Water Quality//704-2; EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: 9/4/2019 AtaccsatAFvazs... Page# NPDES yr/mo/day Inspection Type (Cont.) NCO080691 I11 121 19/08/27 117 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) FLOW MEASUREMENT - EFFLUENT SECTION cont'd: The flow meter was not programmed properly to determine flow rates from the 83 degree V-notch weir. The flow meter was currently programmed to measure flows from a 90 degree V-notch weir. Please be advised that the NPDES Permit requires the following: flow measurement devices be installed, calibrated, and maintained to ensure that the accuracy of the measurements is consistent with the accepted capability of that type of device; flow measurement devices shall be accurately calibrated a minimum of once per year; and devices selected shall be capable of measuring flows with a maximum deviation of less than 10% from the true discharge rates throughout the range of expected discharge volumes. (Permit Condition Reference: Part II, Section D.3 Flow Measurements). Following discussions with the ORC and Aqua NC staff regarding flow meter calibrations, this Office is concerned with the level of training and lack of instrumentation (proper staff gauges, etc.) used to perform these calibrations. Therefore, the Permittee must contract a third party experienced in flow meter calibrations to reprogram and calibrate this flow meter. In addition, this Office recommends a third party recalibrate all flow meters at all Aqua NC WWTPs located in the DWR/Mooresville Regional Office's territory. Page# Permit: NCO080691 Owner - Facility: Windemere WWTP Inspection Date: 08/27/2019 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Overall, the facility is adequately described in the Permit; however, the facility is not equipped with a bar screen. The facility description will need to be updated during the next Permit renewal process. The last compliance evaluation inspection by DWR staff was performed on 6/17/16. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ❑ Page# 3 Permit: NCO080691 Inspection Date: 08/27/2019 Record Keeping Owner - Facility: Windemere WWTP Inspection Type: Compliance Evaluation Yes No NA NE Comment: The records reviewed durina the inspection were oraanized and well maintained. Discharae Monitoring Reports (eDMRs) were reviewed for the period July 2018 through June 2019. No effluent limit violations were reported and all monitoring frequencies were correct. The ORC must ensure that the effluent composite sampling start and end times are documented (verify 24-hr. sampling event) and all on -site documentation is legible. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ 0 ❑ Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ 0 ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ 0 ❑ Comment: On -site field analyses (dissolved oxygen, pH, temperature, total residual chlorine) are performed under Aqua NC's laboratory certification #5035. Water Tech Labs (all permit parameters except field) has also been contracted to provide analytical support. The ORC must ensure to do initial and post calibration checks on the dissolved oxygen meter. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: The subject permit requires composite and grab effluent samples. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The wastewater treatment facility appeared to be properly operated and well maintained. Process control measurements were being documented and maintained on -site. The facility's telemetry -type alarm system functioned properly during the on -site test. Page# 4 Permit: NCO080691 Owner - Facility: Inspection Date: 08/27/2019 Inspection Type: Windemere WWTP Compliance Evaluation Equalization Basins Yes No NA NE Is the basin aerated? 0 ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? ❑ 0 ❑ ❑ Are float controls operable? 0 ❑ ❑ ❑ Are audible and visual alarms operable? 0 ❑ ❑ ❑ # Is basin size/volume adequate? 0 ❑ ❑ ❑ Comment: One of the influent pumps is in the process of being repaired/replaced. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? 0 ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) 0 ❑ ❑ ❑ Comment: The 30-minute settleability tests performed during the inspection were 870/840 ml/L with a clear supernates. The ORC/Permittee must ensure that an adequate sludge wasting program is implemented (via process control program, etc.) to maintain an appropriate solids inventory and sludge age in the aeration basins. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Page# 5 Permit: NC0080691 Owner - Facility: Inspection Date: 08/27/2019 Inspection Type: Windemere WWTP Compliance Evaluation Secondary Clarifier Yes No NA NE Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) 0 ❑ ❑ ❑ Comment: Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Down flow Is the filter media present? 0 ❑ ❑ ❑ Is the filter surface free of clogging? ❑ ❑ ❑ Is the filter free of growth? ❑ ❑ ❑ Is the air scour operational? ❑ ❑ ❑ Is the scouring acceptable? ❑ ❑ ❑ Is the clear well free of excessive solids and filter media? ❑ ❑ ❑ Comment: The air scour system for one of the tertiary filters will be repaired within the near future. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? 0 ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? 0 ❑ ❑ ❑ Comment: De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ 0 ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ 0 ❑ Comment: Are the tablets the proper size and type? 0 ❑ ❑ ❑ Are tablet de -chlorinators operational? 0 ❑ ❑ ❑ Number of tubes in use? 3 Page# 6 Permit: NCO080691 Owner - Facility: Windemere WWTP Inspection Date: 08/27/2019 Inspection Type: Compliance Evaluation De -chlorination Yes No NA NE Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? M ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: The flow meter was last calibrated/verified by the ORC/Aaua NC staff on 8/7/19. See "Summary" Section for additional comments. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The effluent appeared clear with no floatable solids or foam. The effluent is discharged into the receiving stream via submerged outfall. in the receiving stream. Aerobic Digester Yes No NA NE Is the capacity adequate? 0 ❑ ❑ ❑ Is the mixing adequate? 0 ❑ ❑ ❑ Is the site free of excessive foaming in the tank? 0 ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? M ❑ ❑ ❑ Comment: Wastewater solids are removed on an as -needed basis by a contracted company (currently Rick's Septic Tank Service). Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Yes No NA NE ❑ ■ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 7 Permit: NCO080691 Inspection Date: 08/27/2019 Standby Power Owner - Facility: Windemere WWTP Inspection Type: Compliance Evaluation Yes No NA NE Comment: The backup generator currently has to be manually activated. The Permittee must ensure that the operational issues associated with the automatic transfer of power are resolved within the near future. The generator is exercised (automatically) weekly and placed under load (by ORC) quarterly. Aqua NC contracts a company (currently Palmer Generator) to service the generator. Page#