Loading...
HomeMy WebLinkAboutNC0066788_Compliance Evaluation Inspection_20190903DocuSign Envelope ID: 2FEBA7A4-F28C-41C5-BC6F-7E8F2FE1F8D2 ROY COOPER G&v-�rr1ar K41 HAEL S. REGAN Secretary LINDA CULPEPPER i +iC f r Clark Wyatt Buncombe County Schools 175 Bingham Rd Asheville, NC 28806 NORTH CAROUNA Environmental Qual" September 03, 2019 SUBJECT: Compliance Inspection Report Fairview Elementary School NPDES WW Permit No. NCO066788 Buncombe County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Fairview Elementary School on 8/21/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0066788. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me at 828-296-4500 or via email at linda.wiggs@ncdenr.gov. Sincerely, DocuSigned by: 6C38CDE2B5CF449... Linda Wiggs Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Ec: ARO Server, LF G:\WR\WQ\Buncombe\Wastewater\Minors\Fairview Elementary 66788\Inspections\8-21-2019 Insp\20190903_NC0066788_CEI.rtf North Caro iina Department of Erv:rortmenta Quairty I Diusionof Water FesoLmes Ashev;;:e Regiona:Off:ce 1 2090 U.S. 70 1-0glm-ay I Swannsnos, NorLh Csro:ins 2377S DocuSign Envelope ID: 2FEBA7A4-F28C-41C5-BC6F-7E8F2FE1F8D2 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO066788 111 12 I 19/08/21 I17 18 I S J 19 L G] 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70 I I 71 I I 72 I r I u ty 73 I I 174 751 I I I I I I I80 I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 02:30PM 19/08/21 16/01/01 Fairview Elementary School 1355 Charlotte Hwy Exit Time/Date Permit Expiration Date Fairview NC 28730 03:20PM 19/08/21 20/12/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Clark Wyatt,175 Bingham Rd Asheville NC 28806//828-232-4244/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance 0 Facility Site Review 0 Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Linda S Wiggs ps ARO WQ//828-296-4500 Ext.4653/ Timothy H HeimI�IL ARO WQ//828-296-4665/ EW 9/4/2019 9/4/2019 Signature of Management Q A Reviewer Docusigned by: Agency/Office/Phone and Fax Numbers Date 9/4/2019 7E617A38285848C... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: 2FEBA7A4-F28C-41C5-BC6F-7E8F2FE1F8D2 NPDES yr/mo/day Inspection Type (Cont.) 1 NCO066788 I11 121 19/08/21 117 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Linda Wiggs and Tim Heim (DWR) visited the WWTP on 8/21/2019. Ms. Jessica Silver with the Buncombe County Health Department was also present. School began this week; the WWTP could be in transition due to this start up. According to the ORC logbook; soap was present in the EQ on 6/28/2019 and 7/10/2019, the digester was pumped on 7/3/2019. Aeration Basin settleability --25%. D.O. 1-1.5 mg/l. Secondary Clarifier blanket at —4.5' of 9'. WWTP was discharging during the time on site; it was slightly discolored tan and had some foam present. The foam did not persist in the stream but was observed as slightly more than a trace at the outfall. Safety remains an issue at this WWTP. The manhole associated with the effluent pipe has been fixed. Page# 2 DocuSign Envelope ID: 2FEBA7A4-F28C-41C5-BC6F-7E8F2FE1F8D2 Permit: NCO066788 Owner - Facility: Fairview Elementary School Inspection Date: 08/21/2019 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Equalization Basins Yes No NA NE Is the basin aerated? 0 ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ Are float controls operable? ❑ ❑ ❑ Are audible and visual alarms operable? ❑ ❑ ❑ # Is basin size/volume adequate? 0 ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Type of aeration system Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? 0 ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) 0 ❑ ❑ ❑ Comment: Aeration Basin settleability —25%. D.O. 1-1.5 mg/I. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ 0 ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Page# 3 DocuSign Envelope ID: 2FEBA7A4-F28C-41C5-BC6F-7E8F2FE1F8D2 Permit: NC0066788 Owner - Facility: Inspection Date: 08/21/2019 Inspection Type: Fairview Elementary School Compliance Evaluation Secondary Clarifier Yes No NA NE Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) ❑ 0 ❑ ❑ Comment: Blanket elevated. Secondary Clarifier blanket at —4.5' of 9'. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 3 Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ Comment: De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ 0 ❑ Comment: Are the tablets the proper size and type? 0 ❑ ❑ ❑ Are tablet de -chlorinators operational? 0 ❑ ❑ ❑ Number of tubes in use? 3 Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Page# 4 DocuSign Envelope ID: 2FEBA7A4-F28C-41C5-BC6F-7E8F2FE1F8D2 Permit: NC0066788 Inspection Date: 08/21/2019 Effluent Pipe Owner - Facility: Fairview Elementary School Inspection Type: Compliance Evaluation Comment: The manhole associated with the effluent pipe has been fixed. The discharge was slightly discolored tan and had some foam present. Yes No NA NE Page#