Loading...
HomeMy WebLinkAboutNCG551762_Final Permit_20190830ROY COOPER co"". MICHAEL S. REGAN s�rem,, LINDA CULPEPPER Duenor NORTH CAROLINA Environmental Quality August 30, 2019 Angela Del Nero, Owner 429 Dick Watson Road Deep Gap, North Carolina 28618 Subject: Issuance to Certificate of Coverage (COC) / Authorization to Construct (ATC) NPDES General Permit NCG551762 under General Permit NCG550000 Single Family Residence (SFR) 429 Dick Watson Road, Deep Gap Watauga County Dear Ms. Del Nero: In accordance with your application for discharge under the subject NPDES General Permit, the Division of Water Resources (DWR) herewith forwards a Certificate of Coverage (COC) and Authorization to Construct (ATC) permit for new facilities. We issue this permit pursuant to the requirements of North Carolina General Statue 143-215 .1, the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency (EPA) dated October 15, 2007 (or as subsequently amended). Your permit package includes: o Certificate of Coverage (COC) /Authorization to Construct (ATC) a Operation & Maintenance Instructions • A copy of Wastewater Discharge General Permit NCG550000 a A copy of the approved plans and specifications a Engineer's Certification form (to be returned to DWR upon project completion). To maintain your Certificate of Coverage (COC), you must remit an annual fee of $60, due each year on the date of this letter, to the Division of Water Resources. Please include the COC number NCG551762 on your check. Mail your Annual Fee to: NCDEQ / DWR / NPDES / SFR Permitting Attn. Wren Thedford 1617 Mail Service Center Raleigh, NC 27699-1617 DWR understands that the subject property has been judged "unsuitable" for a ground -absorption sewer system by the Watagua County Health Department. Therefore, your authorized consultant, Agri -Waste Technology, Inc., intends to upgrade/install a wastewater treatment system designed to discharge to Surface Waters of the State [in accord with plans and specifications signed by the engineer on May 14, 2019. Compliance under General Permit NCG550000 restricts discharge flow, not to exceed 1,000 gallons per day. This ATC covers treatment facilities for a four -Oh -bedroom single-family residence estimated to discharge 480 gpd (120 gallons per bedroom). j North Carolina Department of Environmental Quality � Division of Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-707-9125 Please note that you must provide regular treatment -system operation, maintenance and inspections in accord with manufacturer's recommendations and this ATC; all records, water analyses, and logs to be kept onsite available for DWR inspection [NCG550000, Section A. (2.)]. Operation and Maintenance. The Permittee is responsible to maintain all components of the approved treatment system, designed to meet Surface Water -Quality Standards. Compliance includes following the manufacturer's guidelines, conducting and documenting inspections, establishing sources for OEM spare parts and supplies, taking samples for analyses, making necessary repairs, and documenting said maintenance for the duration of the permit. Please note that the receiving stream is currently classified and governed as C; Tr +. If DWR determines that your discharge contributes to future degradation or impairment of this waterbody, an individual NPDES permit may be mandatory. Upon DWR's request, the Permittee must provide records and demonstrate regular efforts to maintain the approved treatment system. The Division recommends that the Permittee solicit manufacture -certified training, or a qualified contractor or service to regularly inspect and maintain this treatment system. Authorization to Construct (ATC) Permit. This ATC details the conditions of installation and operation. Before startup, activation requires notice to the Winston-Salem Regional Office (336-776-9800), attention Lon Snider, a minimum of three (3) days in advance of discharge. Such notification shall be made during normal office hours from 8:00 a.m. until 5:00 p.m. Monday through Friday, excluding State holidays. The attached Engineer's Certification form, must be returned to DWR by the Engineer, documenting compliance "as built" in accord with this ATC and approved plans and specifications submitted to DWR on May 14, 2019. No changes may be made without prior approval. Therefore, in accord with the application and the attached approved plans and specifications, DWR hereby authorizes the installation of an upgraded surface -water discharge treatment system described as: • new septic tank with effluent filter • Advantex AX-20 RT Pod • Recirculation pump chamber • UV disinfection • Discharge point with aeration/erosion control (riprap) Compliance with the above shall include a leakage test performed on reused tanks and proposed new tanks, or leak -certified new by the manufacture not to exceed an exfiltration rate of twenty (20) gallons per twenty-four (24) hours per 1,000 gallons of tank capacity. The Engineer's Certification shall serve as proof of compliance with this condition. Mail the completed Engineer's Certification to: DEQ / DWR/ NPDES Program 1617 Mail Service Center Raleigh, NC 27699-1617 d• The Permittee shall, for the life of the treatment facility, maintain on site a copy of the approved plans and specifications available for DWR inspection. All elbow piping must conform to the long -sweeping type. All cleanouts must be housed in meter boxes below grade. This treatment system shall be located at least 15 feet away from a dwelling, at least 100 feet from any water -supply well either on- or off -site. The system shall also be located and constructed above any applicable 100-year flood line; 50-ft setback from property lines. Upon completing construction and prior to operating this permitted facility, a North Carolina -registered engineer shall sign and submit to DWR the attached Engineer's Certification form, thereby certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Certificate of Coverage, this Authorization to Construct, and the approved plans and specifications. This ATC permit is issued in accordance with Part III, Paragraph 2 of NPDES General Permit NCG550000, and is subject to revocation unless wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in this General Permit. In the event that the facilities fail to perform satisfactorily, including creating nuisance conditions, the Permittee shall take immediate corrective action as may be required by this Division, such as the construction of additional or replacement wastewater treatment(s) or disposal facilities. Failure to abide by the requirements of this ATC permit may subject the Permittee to an enforcement action by the Division of Water Resources in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. If any parts, measurement frequencies or sampling requirements contained in this general permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the certificate of coverage shall be final and binding. This COC is not transferable except after notice to the Division of Water Resources. The Division may modify or revoke and reissue this COC. This COC does not affect your legal obligation to obtain other permits that may be required by the Division of Water Resources, the Division of Land Resources, the Coastal Area Management Act, or any other Federal or Local government. NPDES Contact. If you have any questions concerning the requirements of this Certificate of Coverage or Authorization to Construct (ATC) permit, please email Emily DelDuco [Emily.delduco@ncdenr.gov] or call her direct line [919-707-9125]. Linda Culpepper Director, Division of Water Resource Attachments: COC; Engineer's Certification form (to be signed and returned to DWR) hc: NPDES General Permit Files ec: Winston Salem Regional Office, Lon Snider/Kelli Park Kevin Davidson [mailto:kdavidson(a)aeriwaste com] STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES GENERAL PERMIT NCG550000 CERTIFICATE OF COVERAGE NCG551762 TO DISCHARGE DOMESTIC WASTEWATERS FROM SINGLE FAMILY RESIDENCES AND OTHER 100% DOMESTIC DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, the Del Nero residence is hereby authorized to discharge domestic wastewater from a facility located at 429 Dick Watson Road Deep Gap Watauga County to receiving waters designated as an unnamed tributary to Gap Creek in subbasin 05-07-01 of the New River Basin [HUC: 050500010205; Stream Index #: 10-1-23], current classified C;Tr+ waters, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II and III of General Permit No. NCG550000 as attached. This certificate of coverage shall become effective August 30, 2019 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day August 30, 2019 Culpepper, Director 7J� ivision of Water Quality By Authority of the Environmental Management Commission Angela Del Nero - 429 Dick Watson Road N NPDES Permit NCG551762 „s.�oo� Receiving Stream: UT to Gap creek Stream Class: C;Tr:+ Stream Segment: 10-1-23 Sub -Basin k: 05-07-01 River Basin: New HUC: 050500010205 SCALE 36.23390 N,-81.52220 W County: Watauga 1:20,000 NORTH CAROLINA Environmental Quality ROY COOPER MICHAEL S. REGAN I I'll LINDA CULPEPPE.R l I'll Permittee: Angela Del Nero NPDES Permit / COC Number: NCG551762 Countv: Engineer's Certification: I, Watauga a duly registered Professional Engineer in the State of North Carolina, as authorized by the Permittee to observe [ daily, part time, full time ] the construction of the project, Project Name do hereby state that to the best of my abilities, I practiced due care and diligence to observe the construction of said project such that it was advanced and completed in accordance and in compliance with the NPDES Permit, approved plans and specifications, Authorization to Construct Permit, and/or General Permit Certificate of Coverage issued by the Division of Water Resources. Signature Registration Date [Stamp] [Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $10,000, or by imprisonment not to exceed six months, or by both. [18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment not more than 5 years, or both, for a similar offense.] j �—� North Carolina Department of Environmental Quality I Division of Water Resources 1617 Mail service Center I Raleigh, North Carolina 27699-1617 919-707-9125