August 12, 2019
Ms. Terra Greene, City Manager
City of Lexington
28 West Center Street
Lexington, NC 27292
RECEIVED/NODEQ/DWR
SUBJECT: Notice of Deficiency
NOD-2019-PC-0179 AUG 2 7 a0l9
Compliance Evaluation Inspection Water Quality
City of Lexington WW u
TP Permitting Section
NPDES Permit# NC0055786
Davidson County
Dear Ms. Greene:
On July 31,2019, Gary Hudson of this office met with Tom Johnson, Water Resources Utilities
Director and Eglantine Minerali, Laboratory Supervisor, to perform a Compliance Evaluation
Inspection on the City of Lexington wastewater treatment system. This type of inspection
consists of two basic parts: an in-office file review and an on-site inspection of the treatment
facility. The attached EPA inspection form notes the areas that were evaluated for this
inspection. The findings and observations are outlined below:
Permit
The NPDES permit became effective February 1, 2016 and expired on April 30, 2019.
Self-Monitoring Program
The monthly self-monitoring reports were reviewed for the period of August 2018 through June
2019. The facility was in complete compliance for the above review period, except for a daily
pH in January 2019.
Flow Measurement
The flow meter was calibrated on February 18, 2019.
Sludge Handling and Disposal
Sludge is wasted to the sludge holding tanks (two abandoned anaerobic digesters). The only
way that sludge can leave the wastewater treatment plant is through the compost facility, which
North Department Env Quality I ofi Resources
N
WinstonCarolina Salem Regional Officeof 1450 Hanesironmental Mill Road,SuiteDivision 300 I Water Winston Salem North Carolina 27105
NORM4 Dep Emlnearenftl ortmost 336.776.9800
•
appeared to be undersized and antiquated., It appeared that sludge solids were seriously ,
backed up and were not being processed quick enough to facilitate wasting of the activated
sludge. Our office strongly recommends that the City of Lexington improve its residual solids
management plan so that the proper amount of sludge can be wasted from the secondary
process.
Operations and Maintenance
The system appeared to be clean and well kept. With the exception of the residual solids
disposal issues, no problems were noted.
Records and Reports
All records and reports appeared to be very thorough and complete.
Effluent/Receiving Waters '
The effluent discharges into Abbotts Creek, Class WS-V and B waters in the Yadkin—Pee Dee
River Basin. The effluent appeared to be very clear on the day of the inspection.
If you have any questions concerning this report, please call Gary Hudson or me at(336) 776-
9800.
Sincerely,
CDocuSigned by:
L.?, T 5A,lcr
145B49E225C94EA...
Lon Snider
Regional Supervisor
Water Quality Regional Operations
Division of Water Resources
cc: Tom Johnson, Water Resources Utilities Director •
Central Files
'_NPDES Files J
WSRO FILES
United States Environmental Protection Agency Form Approved.
EPA Washington,D C 20460 OMB No 2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A:National Data System Coding(i.e.,PCS)
Transaction Code NPDES - yr/mo/day Inspection Type Inspector Fac Type
1 El 2 LI 3 NC0055786 111 121 19/07/31 117 18 l r.I 19 Li I 201
21IIII I I I I I III I I I I I I I I I I I I I I I I I I I I I I III I II 11 l66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved
67 I I 70 I I 71 LI 72 I N I 731
I 174731
I I I I I I 180
l Section B.Facility Data
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date s Permit Effective Date
POTW name and NPDES permit Number) 09 30AM 19/07/31 16/02/01
Lexington Regional WWTP
500 Glendale Rd Exit Time/Date Permit Expiration Date
12-00PM 19/07/31 19/04/30
Lexington NC 27292
Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data
///
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
Joseph Shaffer,28 W Center St Lexington NC 27292/Utility Plant
Supervisor/336-357-5090/3363577369 - No
Section C:Areas Evaluated During Inspection(Check only those areas evaluated)
Permit Flow Measurement III Operations&Maintenance Records/Reports
II Self-Monitoring Program II Sludge Handling Disposal II Facility Site Review II Effluent/Receiving Waters
Section D-Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Gary Hudson Division of Water Quality//336-776-9694,
/6AUG/q
Signature of Man ment Q A Revie ttec-Docusigned by. Agency/Office/Phone and Fax Numbers Date
Loti �[ SMatC- 8/16/2019
—,�cnnncnggrnern
EPA Form 3560-3(Rev 9-94)Previous editions are obsolete
Page# 1
NPDES yr/mo/day Inspection Type 1
31 NC0055786 111 121 19/07/31 117 18 i,.I
Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
Page# 2
Permit: NC0055786 Owner-Facility: Lexington RegionalWWfP
Inspection Date: 07/31/2019 Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new • 0 0 0
application'?
Is the facility as described in the permit? • 0 0 0
#Are there any special conditions for the permit'? 0 • 0 0
Is access to the plant site restricted to the general public'? III ❑ ❑ 0
Is the inspector granted access to all areas for inspection'? M 0 0 ❑
Comment: _
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit'? • 0 0 0
Is all required information readily available, complete and current'? • ❑ ❑ ❑
Are all records maintained for 3 years(lab reg required 5 years)? • 0 0 0
Are analytical results consistent with data reported-on DMRs? • 0 0 0
Is the chain-of-custody complete? • 0 0 0
Dates, times and location of sampling •
Name of individual performing the sampling •
Results of analysis and calibration III
Dates of analysis U
Name of person performing analyses •
Transported COCs •
Are DMRs complete do they include all permit parameters'? • ❑ 0 0
Has the facility submitted its annual compliance report to users and DWQ? • 0 0 0
(If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator • 0 0 0
on each shift'?
Is the ORC visitation log available and current'? • 0 Cl ❑
Is the ORC certified at grade equal to or higher than the facility classification'? • 0 0 0
Is the backup operator certified at one grade less or greater than the facility classification'? MI 0 0 0
Is a copy of the current NPDES permit available on site? II 0 0 0
Facility has copy of previous year's Annual Report on file for review'? III 0 0 0
Comment:
Influent Sampling Yes No NA NE
#Is composite sampling flow proportional'? MOOD
Is sample collected above side streams'? • ❑ ❑ ❑
' Page# 3
Permit: NC0055786 Owner-Facility: Lexington Regional WWTP
Inspection Date: 07/31/2019 Inspection Type: Compliance Evaluation
Influent Sampling Yes No NA NE
Is proper volume collected? • ❑ 0 0
Is the tubing clean? II 0 ❑ ❑
#Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 0 ❑
Celsius)?
Is sampling performed according to the permit? • 0 ❑ 0
Comment:
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional'? II 0 0 ❑
Is sample collected below all treatment units'? • ❑ 0 ❑
Is proper volume collected? III 0 ❑ ❑
Is the tubing clean'? • ❑ ❑ 0
#Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees • 0 0 0
Celsius)?
Is the facility sampling performed as required by the permit(frequency,sampling type II 0 0 0
representative)?
Comment:
Flow Measurement-Effluent Yes No NA NE
#Is flow meter used for reporting'? • 0 ❑ 0
Is flow meter calibrated annually'? U ❑ ❑ ❑
Is the flow meter operational? • ❑ ❑ ❑
(If units are separated) Does the chart recorder match the flow meter' 0 ❑ • ❑
Comment
Operations &Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping'? • ❑ ❑ ❑
Does the facility analyze process control parameters,for ex MLSS, MCRT, Settleable • 0 0 ❑
Solids, pH, DO, Sludge Judge, and other that are applicable'?
Comment:
Secondary Clarifier - Yes No NA NE
Is the clarifier free of black and odorous wastewater'? • ❑ 0 ❑
Is the site free of excessive buildup of solids in center well of circular clarifier'? • 0 ❑ 0
Page# 4
• Permit: NC0055786 Owner-Facility: Lexington Regional WWTP
Inspection Date: 07/31/2019 Inspection Type: Compliance Evaluation
Secondary Clarifier Yes No NA NE
Are weirs level'? • ❑ ❑ ❑
Is the site free of weir blockage'? • 0 ❑ ❑
Is the site free of evidence of short-circuiting'? • 0 ❑ 0
Is scum removal adequate'? • ❑ ❑ ❑
Is the site free of excessive floating sludge'? • ❑ ❑ 0
Is the drive unit operational'? • ❑ 0 ❑ .
Is the return rate acceptable(low turbulence)' ❑ ❑ ❑
Is the overflow clear of excessive solids/pin floc'? • ❑ 0 ❑
Is the sludge blanket level acceptable'?(Approximately%4 of the sidewall depth) • ❑ 0 ❑
Comment:
Aeration Basins Yes No NA NE
Mode of operation Plug flow
Type of aeration system Diffused
Is the basin free of dead spots' ❑ 0 ❑
Are surface aerators and mixers operational'? • ❑ ❑ ❑
Are the diffusers operational'? • ❑ ❑ ❑
Is the foam the proper color for the treatment process? • ❑ ❑ ❑
Does the foam cover less than 25%of the basin's surface'? II ❑ ❑ ❑
Is the DO level acceptable'? • ElEl El
Is the DO level acceptable?(1 0 to 3 0 mg/I) - • ElEl El
Comment _
Bar Screens Yes No NA NE
Type of bar screen
a Manual El
b Mechanical •
Are the bars adequately screening debris'? • ❑ 0 ❑
Is the screen free of excessive debris'? II 0 0 0
Is disposal of screening in compliance'? • ❑ ❑ 0
Is the unit in good condition'? IN ❑ ❑ ❑
Comment: - .
Page# 5
Permit: NC0055766 Owner-Facility: Lexington Regional WWTP
Inspection Date: 07/31/2019 Inspection Type: Compliance Evaluation
Pump Station -Influent Yes No NA NE
Is the pump wet well free of bypass lines or structures'? • ❑ ❑ 0
Is the wet well free of excessive grease? • ❑ 0 0
Are all pumps present? • 0 ❑ ❑
Are all pumps operable? _ • ❑ ❑ ❑
Are float controls operable? ❑ ❑ 0
Is SCADA telemetry available and operational'? 0 0 III ❑
Is audible and visual alarm available and operational'? 0 0 ❑ •
Comment
Grit Removal Yes No NA NE
Type of grit removal
a.Manual 0
b.Mechanical 111
Is the grit free of excessive organic matter'? • ❑ 0 0
Is the grit free of excessive odor? MI ❑ 0 0
#Is disposal of grit in compliance'? - - • 0 0 ❑
Comment: _
Disinfection-Liquid Yes No NA NE
Is there adequate reserve supply of disinfectant'? ❑ 0 ❑
(Sodium Hypochlonte) Is pump feed system operational'? • ❑ ❑ ❑
Is bulk storage tank containment area adequate'?(free of leaks/open drains) • 0 0 ❑
Is the level of chlorine residual acceptable'? 0 ❑ ❑
Is the contact chamber free of growth, or sludge buildup'? • ❑ ❑ ❑
Is there chlorine residual prior to de-chlorination? - • 0 ❑ 0
Comment:
De-chlorination Yes No NA NE
Type of system? Liquid
Is the feed ratio proportional to chlorine amount(1 to 1)? - • ❑ ❑ ❑
Is storage appropriate for cylinders'? 1111000
#Is de-chlorination substance stored away from chlorine containers'? • ❑ ❑ ❑
Comment
Page# 6
• Permit: NC0055766 Owner-Facility: Lexington Regional WNTP
Inspection Date: 07/31/2019 Inspection Type: Compliance Evaluation
De-chlorination Yes No NA NE
Are the tablets the proper size and type? ❑ ❑ II ❑
Are tablet de-chlorinators operational? ❑ ❑ MI ❑
Number of tubes in use?
•
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? • ❑ ❑ ❑
Are the receiving water free of foam other than trace amounts and other debris? � ❑ ❑ ❑
If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ I ❑
Comment:
Page# 7