Loading...
HomeMy WebLinkAboutWI0700493_Other_20190819NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL NOTIFICATION OF INTENT TO CONSTRUCT OR OPERATE INJECTION WELD These wells are `permitted by rule " and do not require an individual permit when constructed in accordance wimp the rules of 15A NCAC 02C .0200. This notice must be submitted prior to construction. ,9 G� k ' 41 GEOTHERMAL AQUEOUS CLOSED -LOOP WELLS As described in 15A NCAC 02C .0222 these wells circulate potable water only or a mixture of ter at%& performance -enhancing additives as part of a geothermal heating and cooling system?,9 OR GEOTHERMAL DIRECT EXPANSION CLOSED -LOOP WELLS As described in 15A NCAC 02C .0223 these wells circulate a refrigerant gas as part of a geothermal heating and cooling system. Print Clearly or Type Information. Illegible Submi t aRls_F ill Be Returned As Incomplete DATE: Aug. 19 2019 PERMIT NO. V"" O l (to be completed by DWR) A. TYPE OF GEOTHERMAL CLOSED -LOOP WELL TO BE CONSTRUCTED (1) Aqueous (as per 15A NCAC 02C .0222): Number of wells: 3 (2) Direct Expansion (as per 15A NCAC 02C .0223) _� Number of wells: _ B. STATUS OF WELL OWNER (choose one) (1) Single Family Residence ✓ Submit this form two (2) business days prior to construction. (2) Business/Organization Submit this form 30 days prior to construction. (3) Government: State Municipal County ]a Federal _a Submit this form 30 days prior to construction. C. WELL OWNER — For single family residences list the property owner(s). For all others, list name of the business, organization, or government agency and person delegated signature authority: Justin McCotter Mailing Address: 101 Trent Villa Landing Dr. City: New Bern State: N_C Zip Code:28562 County: Craven Day Tele No.: 252-671-0756 Cell No.: EMAIL Address: Justin@slawed.com Fax No.: D. PHYSICAL LOCATION OF WELL SITE (1) Parcel Identification Number (PIN) of well site: 7-001 -8003 County: Craven (2) Physical Address (if different than mailing address): 101 Trent Villa Landing Dr. City: New Bern State: NC Zip Code: 28562 UIC/Closed-Loop Geothermal Notification (Revised 8/5/2013) Pagc I E. MAPS, PLANS, AND SPECIFICATIONS (1) Maps must be scaled or otherwise accurately indicate distances and orientations of features located within 250 feet of the injection well(s). Label all features clearly and include a north arrow. Attach a site -specific map showing the locations of the following: • Proposed injection well locations • Septic systems and associated spray irrigation • Buildings sites, drain fields, or repair areas • Property boundaries • Surface water bodies • Existing or potential sources of groundwater • Water supply wells contamination (2) Plans and specifications of the surface and subsurface construction details of the well system. F. TYPES AND CONCENTRATIONS OF ADDITIVES — List any additives that will be used and their concentrations. Only additives that the Department of Health and Human Services' Division of Public Health determines do not adversely affect human health shall be used. A list of approved additives can be found online at hgp:Hportal.ncdenr.org/web/wq/aps/gwpro. All other additives require approval prior to use. G. None WELL DRILLER INFORMATION (if known) Well Drilling Contractor's Name: Sanford Sweeting NC Well Drilling Contractor Certification No.: 2082-A A 1'ie AD M Company Name: PP esource anagement Contact Person: Jim Corvette City: Hampstead State: NC Zip Code: 28443 County: Pender Day Tele No.: 910-270-2919 EMAIL Address: Cell No.: 910-512-4890 Fax No.: 910-270-2988 H. HEAT PUMP CONTRACTOR INFORMATION Company Name: Climate Control Heating & Cooling Co., Inc. Contact Person: Mike Hadley EMAIL Address: mikehadley@geoguys.net Address: 102 Middle St City: Jacksonville Zip Code: 28546 State: NC County: Onslow Office Tele No.: 910-353-9040 Cell No.: 910-376-1100 Fax No.: 910-353-1060 UIC/Closed-Loop Geothermal Notification (Revised 8/5/2013) Pale 2 I. PROTECTION — Provide a brief description of how (1) water supply wells; (2) surface water bodies; and (3) septic systems and associated spray irrigation sites, drain fields, or repair areas within 250 feet of the proposed injection wells will be protected during construction of the wells: Uncontrolled spoils shall be contained either by berms around the affected area or by silt fence. A hole dug into the ground at or near the drilling area maybe used to contain drilling/grouting spoils if necessary. J. VARIANCE — Pursuant to 15A NCAC 02C .0241 the Director of the Division of Water Resources may grant a variance from applicable well construction or operation standards provided that: (1) use of the well(s) will not endanger human health and welfare or the groundwater; and (2) that construction or operation in accordance with the standards is not technically feasible or the proposed construction provides equal or better protection of the groundwater. Any variance request should accompany submittal of this notification to expedite evaluation of the request. The variance request form can be accessed online at hltp://pL)rtal.ncdenr.org/web/wg/aps/gwpro/Termit- gpplications K. SIGNATURES — The following section is to be completed as required below or by that person's authorized agent. 15A NCAC 02C .0211(e) requires signatures as follows: (a) for a corporation: by a responsible corporate officer; (b) for a partnership or sole proprietorship: by a general partner or the proprietor, respectively; (c) for a municipality or a state, federal, or other public agency: by either a principal executive officer or ranking publicly elected official; (d) for all others: by the well owner; (e) for any other person authorized to act on behalf of the applicant: documentation shall be submitted with the notification that clearly identifies the person, grants them signature authority, and is signed and dated by the applicant. "I hereby certify, under penalty of law, that I have personally examined and am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility offines and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurte nces in accordance with the 15A NCAC 02C 0200 Rules. Signature of Property Owner/Applicant Justin McCotter Print or Type Full Name Signature of Authorized Agent, if any Print or Type Full Name UIC/Closed-Loop Geothermal Notification (Revised 8/5/2013) Page 3 L. SUBMITTAL INSTRUCTIONS — Submit one copy of the completed notification package to the each of the following: (1) (2) The Division of Water Resources Regional Office serving the area in which the injection well facility will be located: WINSTON-SALEM ASHEVILLE Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Telephone: (828) 2964500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5043 Telephone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Telephone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 1628 Mail Service Center Raleigh, NC 27699-1628 Telephone: (919) 791-4200 Fax: (919) 571-4718 LC RALEIGH WASHINGTON FAYETTEVILLE Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Telephone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 29405 Telephone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 585 Waughtown Street Winston-Salem, NC 27107-2241 Phone: (336) 771-5000 Fax: (336) 771-4631 County Health Department in which the injection well facility will be located. A list of county health departments can be found online at http://www.ncalbd.oriz/couniy.htm. UIC/Closed-Loop Geothermal Notification (Revised 8/5/2013) Page 4 Vertical Geothermal Loop Detail SUPPLY PIPE GEOTHERMAL LOOP HEAT EXCHANGER PIPING MUST BE PRESSURE TESTED PRIOR TO INSTALLATION IN WELL. REFER TO SPECIFICATIONS FOR REQUIREMENTS. L 6° - --�-- EARTH BACKFILL RETURN PIPE POLYETHYLENE PIPE AS SPECIFIED MIN. BURY DEPTH 3'-O" 6tQQRDMT(xA&RQw3Fc BOREHOLE- DRILL SMALL AS POSSIBLE BUT NOT MORE THAN 6" 3ACKFILL ENTIRE BORE WITH THERMALLY ENHANCED GROUT AS SPECIFIED 250 FT. BORE DEPTH or as specified JLYETHYLENE FITTINGS WITH HEAT WELDED CONNECTION Climate Control Htg & Clg Jacksonville, NC 910-353-9040 Mike Hadley CGD CGI GROUT PUMP I SUCTION NOTES: (GROUT PIPE) I 10 PRESSURIZED GROUT SHALL BE PUMPED 1 FROM THE BOTTOM TO THE TOP OF BOREHOLE. DISCHARGE (GROUT PIPE) ----------- 7-TRENCH 20 BEFORE GROUTING IS PERFORMED, L CONTRACTOR SHALL VERIFY WELL DEPTH. DEPTHS SHALL BE RECORDED BY THE CONTRACTOR'S QUALITY CONTROL EMPLOYEE, KEPT AS SEPERATE LOG. IF THE DEPTH IS NOT AS SPECIFIED, GROUTING SHALL BE r STOPPED UNTIL WELL DRILLER HAS DRILLED /I THE WELL TO THE SPECIFIED LENGTH. O3 GROUT SHALL BE THERMALLY ENHANCED /y . BENTONITE GROUT, WITH A MINIMUM THERMAL �y'/ CONDUCTIVITY OF 1.0 BTU/(HR*FT* F). WELL FIELD PIPE_ GROUT METHOD W/ PUMP✓ SCALE: NOT TO SCALE 010 GROUT BOREHOLE WALL Mike Hadley, CGD CGI Climate Control Htg & Clg Co. Jacksonville, NC 910-353-9040 Proposed Vertical Geothermal Loop Field Justin McCotter 101 Trent Villa Landing Dr. New Bern, NC 28562 Trent River Min 50' from waters edge min 20' seperation \ 0 Proposed Vertical Loop Field min 50' seperation from septic system Septic Tank & Field Submitted by: Mike Hadley CGD CGI Climate Control Htg & Clg Co Jacksonville, NC 28546 910-353-9040