HomeMy WebLinkAboutNC0071897_Inspection_20190823EPA
United States Environmental Protection Agency
Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NC0071897 19/08/14 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Henderson's Assisted Living WWTP
74 Lotus Ln
Hendersonville NC 28792
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
11:35AM 19/08/14 16/01/01
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Shannon D James/ORC/828-697-0063/
Other Facility Data
12:15PM 19/08/14 20/11/30
Name, Address of Responsible Official/Title/Phone and Fax Number
Robert Crummie,PO Box 999 Mountain Home NC 287580999//828-676-9063/Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Operations & Maintenance Sludge Handling Disposal Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Daniel J Boss ARO WQ//828-296-4658/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
DocuSign Envelope ID: 6DB49DBD-5C94-407D-ADD6-DF9359C9E09B
8/26/2019
8/26/2019
NPDES yr/mo/day
19/08/14
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
On 8/14/2019 I (Daniel Boss) met with Shannon James (ORC) and Juanita James for a compliance
evaluation inspection of the Henderson's Assisted Living WWTP. The plant appeared to be operating
well, considering the poor condition of the facility.
There are several things in need of repair at this WWTP. The tertiary filters are not functional. The bar
screen is very dilapidated. A grease trap is needed for the facility. There is a hole in the metal wall
between the aeration basin and the aerobic digester.
NC0071897 17 (Cont.)
Page#2
DocuSign Envelope ID: 6DB49DBD-5C94-407D-ADD6-DF9359C9E09B
Permit:NC0071897
Inspection Date:08/14/2019
Owner - Facility:
Inspection Type:
Henderson's Assisted Living WWTP
Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment:
Bar Screens Yes No NA NE
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
The bar screen is rusting away.Comment:
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Type of aeration system Diffused
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin’s surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/l)
Page#3
DocuSign Envelope ID: 6DB49DBD-5C94-407D-ADD6-DF9359C9E09B
Permit:NC0071897
Inspection Date:08/14/2019
Owner - Facility:
Inspection Type:
Henderson's Assisted Living WWTP
Compliance Evaluation
Aeration Basins Yes No NA NE
DO- 1.6 mg/L; pH- 7.2; Settleable solids measured at 58% at 30min. There is a hole in the
metal between the aeration basin and the aerobic digester.
Comment:
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth)
There was some floating sludge in the clarifier. The sludge blanket was not measured but I
could see several feet down into the clarifier.
Comment:
Disinfection-Tablet Yes No NA NE
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Number of tubes in use?1
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de-chlorination?
Comment:
De-chlorination Yes No NA NE
Type of system ?Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de-chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
Page#4
DocuSign Envelope ID: 6DB49DBD-5C94-407D-ADD6-DF9359C9E09B
Permit:NC0071897
Inspection Date:08/14/2019
Owner - Facility:
Inspection Type:
Henderson's Assisted Living WWTP
Compliance Evaluation
De-chlorination Yes No NA NE
Are tablet de-chlorinators operational?
Number of tubes in use?1
Comment:
Filtration (High Rate Tertiary)Yes No NA NE
Type of operation:
Is the filter media present?
Is the filter surface free of clogging?
Is the filter free of growth?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids and filter media?
The tertiary filters are not functional.Comment:
Aerobic Digester Yes No NA NE
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Page#5
DocuSign Envelope ID: 6DB49DBD-5C94-407D-ADD6-DF9359C9E09B