Loading...
HomeMy WebLinkAboutwq0028587_Permit (Modification)_20080718North Carolina Department of Environment and Natural Resources Divisi-on of Water Quality ,r W A TARO Michael F. Easley, Governor July 18, 2008 William Farris, Town Manager Town of Leland 102 Town Hall Drive Leland, NC 28451 William G. Ross, Jr., Secretary Coleen H. Sullins, Director Subject: Permit No. WQ0028587 MODIFICATION Town of Leland Brunswick Forest Sewer Wastewater Collection System Extension Brunswick County Dear Mr. Farris: In accordance with your application received June 19, 2008, we are forwarding herewith Permit No. WQ0028587 dated July 18, 2008, to the Town of Leland for .the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from �fhe date of issuance until rescinded, shall void Permit No. WQ0028587 issued October 12, 2007 and shall � be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference This modification adds approximately 1,630 linear feet of 8-inch gravity sewer to serve commercial development in East Village Phase-1. In addition this reduces the reserve allocation by 18,182 GPD. By copy of this permit, the Town of Leland Building Inspections Department is advised that, no certificates of occupancy are to be granted prior to the submittal of a sealed engineer's certification per Condition 6 of this permit. Please note the following standard conditions that are contained in this permit. < Condition 3: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system -permit issued to the Permittee. Condition 6: Requires-thaflhe system be properly certified upon completion of construction and- "'rior to being placed into operation. Wilmington Regional Office „,1, 1'„ 127 Cardinal Drive Extension Wilmington, NC 28405 NOnl 111CaT011lla Phone: 91 ww.ncvva / FAX: ".or 0-2004 Natur49 Internet: www.ncwaterquality.orq MY An Equal Opportunity/Affirmative Action Employer Customer Service 1-877-623-6748 50% Recycled/10% Post Consumer Paper r- Town of Leland WQ0028587 July 18, 2008 Condition 7: Regarding the installation of gravity sewer at greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until, corrected. Condition 12: Regarding Division notification should the system fail to operate including the loss of wastewater from the collection system. In addition, note Permit Condition 13 regarding the posting of pump stations with emergency contact information. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer. Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by the North Carolina -licensed Professional Engineer named in the application. It shall be the Town of Leland's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute § 143-215.6A through § 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. This permit shall become voidable unless the agreement between the Town of Leland and Brunswick County for the collection and final treatment of wastewater is in full force and effect. A stormwater management plan shall be submitted to and approved by the Wilmington Regional Office in accordance with 15A NCAC 2H .1000. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Lamont Allen at (910) 796- 7215. l y, Coleen H. Sullins Cc: David Hollis, Hanover Design Services Tim Evans, Town of Leland Building Inspections Department Jerry Pierce, Brunswick County Public Utilities WJRO Surfac-e-Water-Pro_teetion—NE_Brunswick Re9iQff(jl_-(.%COQ86819_)_S_ew�t=File Central Files, Surface Water Protection Section Pretreatment, Emergency Response and Collection Systems Unit Files 2 .t NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF MVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, other applicable Laws, Rules, and Regulations, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit; PERMISSION IS HEREBY GRANTED TO: TOWN OF LELAND BRUNSWICK. COUNTY For the construction and operation upon certification of approximately 1,630 linear feet of 8-inch gravity sewer to serve a 49,170 sf Grocery Store (4,920 gpd), 84,370 sf of Retail Space with no food services (8,437 gpd), a 13,225 sf Pharmacy (1,325 gpd), a 30 space Restaurant Drive-Thru (1,500 gpd) and a 50 seat Restaurant (2,000 gpd) as part of the East Village Phase-1 project, -and the discharge of 18,182 gallon per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received June 19, 2008. AND The continued construction and operation upon certification OR operation of the sewer infrastructure as described below and previously permitted In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit: October 12, 2007 Modification The construction and operation upon certification of approximately 1,174 linear feet of 8-inch gravity sewer to serve 62 three -bedroom and 10 two -bedroom residences as part of the Phase 1 Section 2 Village 4-A project, and the discharge of 24,720 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received September 18, 2007. September 7, 2007 Modification Construction and operation.uoon certification of approximately 2,952 linear feet of 8-inch gravity sewer to serve 72 three -bedroom residences as part of the Phase 1 Section 2 Village 1-A project, and the discharge of 25,920 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received July 25, 2007. June 8, 2007 Modification Continued operation of approximately 1,393 linear feet'of 8-inch gravity sewer to serve` Lots 1 & 2 for a bank with 10 employees (250 gpd) and an unspecified-d-veT6pment on the other (will require allocation to be added prior to connection) as part of the East Village Commercial Center project, and the discharge of 250 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received May 16, 2007. This system was certified as complete on December 6, 2007. April 20, 2007 Modification Construction and operation of approximately 5,065 linear feet of 8-inch gravity sewer to serve 94 three - bedroom single-family residences as part of the Brunswick Forest Phase 1 Section 3 project, and the discharge of 33,840 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received March 29, 2007. April 13, 2007 Modification Continued operation of approximately 5,126 linear feet of 8-inch gravity sewer to serve 56 three - bedroom single-family residences and 30 three -bedroom & 30 two -bedroom townhomes as part of the Brunswick Forest Phase 6 'Sections 1-B & 2 project, and the discharge of 38,610 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received March 9, 2007. This system was certified as complete on November 30, 2007. December 22, 2006 Modification Construction and operation upon certification of approximately 13,874 linear feet of 8-inch gravity sewer; a 387-gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms, telemetry, and on -site generator with automatic transfer switch; as well as approximately 3,520 linear feet of 6-inch force main to serve 193 three -bedroom residences as part of the Brunswick Forest Phase 1 Section 2 project, and the discharge of 69,480 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received December 1, 2006. October 27, 2006 Modification Continued operation of approximately 1,008 linear feet of 8-inch gravity sewer to serve future development including a sales center & wellness facility in Brunswick Forest Phase 6 Section 1-A as part of the Brunswick Forest project and the discharge of 800 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received September 15, 2006. This system was certified as complete on June 15, 2007. May 26, 2006 Modification Continued operation of approximately 5,926 linear feet of 8-inch gravity sewer; a 380-gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms, telemetry, and on -site generator with automatic transfer switch; as well as approximately 3,915 (increased from 2,821 feet per modification issued November 3, 2006) linear feet of 6-inch force main to serve 149 three -bedroom residences as part of the Jefferson Landing at Brunswick Forest Phase 2 (aka Phase 1 Section 1-B) project, and the discharge of 53,640 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application originally received April 24, 2006 and subsequent modification request received September 25, 2006. This system was certified as complete on March 27, 2007. 2 April 7, 2006 Modification Continued operation of approximately 793_linear feet of 10-inch, and 2,329 (reduced from 3,830) linear feet of 1.24rich gravity sewer to serve- as a gravity sewer outfall or interceptor line for future upstream or tributary sewer systems as part of the Brun, swick Forest Phase 3 project with no additional discharge of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received February 16, 2006. This system was -certified as complete on March 15, 2007. March 10, 2006 Modification Continued operation of approximately 6,741 linear feet of 8-inch gravity sewer to serve 131 three - bedroom residences as part of the Jefferson Landing at Brunswick Forest Phase 1 (aka Phase 1 Section 1-A) project, and the discharge of 47,160 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application received February 14, 2006. This system was certified as complete on December 22, 2006. JULY 21, 2005 MODIFICATION Construction and operation upon certification of approximately 25 linear feet of 8-inch and 3,290 linear feet of 12-inch gravity sewer to serve as a gravity sewer outfall or interceptor line for future development upstream of the previously approved sewer listed below as part of the Brunswick Forest Phase 2 project, and with no additional discharge of collected wastewater into the Town of Leland's existing sewerage system, pursuant to the application received June 15, 2005, March 24, 2005 Original Permit Continued operation of approximately 868 linear feet of 8-inch, 3,414 linear feet of 10-inch, and 3,141 linear feet of 12-inch gravity sewer; a 1500-gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms, telemetry/autodialer, and on -site generator with automatic transfer switch; as well as approximately 20,650 total linear feet of 10-inch force main (dual force mains) to serve this large residential and commercial development as part of the Brunswick Forest Phase 1 project with no discharge of wastewater into the Town of Leland's existing sewerage system, pursuant to the application received March 11, 2005. This system was certified as complete on March 15, 2007. From the original permit 23,368 cgpd of flow allocation remains in reserve as of the July 18 2008 modification. In summary, this permit authorizes the potential connection of 693 three -bedroom & 40 two -bedroom ,residences, a sales center, a wellness facility, a bank, a garden center, grocery store, retail space, pharmacy, restaurant drive-thru, and a restaurant for a total discharge of 312,602, gallons per day. The sewage and wastewater collected by this system shall be treated in the Northeast Brunswick Regional Wastewater Treatment Facility (Permit No. NC0086819) prior to being discharged into' the receiving stream. This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual 'system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403., If an individual permit is not required, the following performance criteria 5.bG14-be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of'the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory, and overflow response shall be developed and implemented. d. Pump stations that are not connected to a telemetry system (i.e. remote alarm system) shall be inspected by the Permittee or its representative every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected by the Permittee or its representative at least once per every six-month period of time. A general observation of the entire sewer system shall be conducted by the Permittee or its representative at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute § 143-215.1 C. h. A Grease Control Plan shall be implemented as follows: For publicly owned collection systems, the Program shall include at least bi-annual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors for new construction and retrofit, if necessary, of grease interceptors at existing establishments. The Program shall also include legal means for inspections of the grease interceptors, enforcement for violators, and the legal means to control grease entering the system from other public or private satellite sewer systems. 2. For privately owned collection systems, the Program shall include at least bi-annual distribution of educational materials to all users of the collection system by the Permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts 1 or 2 of this sub -paragraph if necessary to prevent grease -related sanitary sewer overflows. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept on file for Sections (a.) through (i.) of this rule for a minimum of three (3) years with the exception of the map, which shall be maintained for the life of the system. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 4 6. Per 15A NCAC 2T .01 16, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting docurrrents (as -built or recording drawings and pump station designs, if applicable) to the address provided -on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be cpnsidered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation Declarations and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Record drawings are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, ,etc. b. One copy of the supporting pump station design calculations (selected pumps, system curve, operating point, buoyancy calculations, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project. C. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the-number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. 7. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. 8. A copy of the construction record drawings and pump station designs, if applicable, shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes § 143- 215.6A through § 143-215. 5 10. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additionakor replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 12. NON-COMPLIANCE NOTIFICATION: The Permittee shall verbally report to a Division of Water Quality staff member at the Wilmington Regional Office, telephone number (910) 796-7215, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any failure, due to known or unknown reasons, that renders the system incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass of any wastewater directly to receiving waters from the station or sewer line. Voice mail messages or faxed information is permissible, but shall NOT be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 13. Each pump station including simplex stations shall be clearly and conspicuously posted with the telephone number and name of the owner/operator of the sewer system and instructions to call the number in the event of alarm activation. 14. The Permittee shall provide for the pump station and force main the following items: a. Pump on/off elevations located so that 2-8-pumping cycles may be achieved per hour in the pump station, b. An air relief valve located at all high points along the force main, C. A screened vent for the wet well, d. Fillets located in the wet well at the intersection of the flooring and 'sidewalls, e. Three feet of cover (minimum) over the force main or the use of ferrous material where three feet cannot be maintained, f. Sufficient devices which will protect the pump station from vandals, and g. Flood protection if the pump station is located below the 100-year flood elevation. N. Permit issued.this day: July 18, 2008 NORTH CAR INA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0028587 7 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: Town of Leland ,_• --- PERMIT #: WQ0028587 PROJECT: Brunswick Forest East Village Phase-1 ISSUE DATE:' July 18, 2008 COUNTY: Brunswick This project shall not be considered complete nor allowed to operate in accordance with Condition 6 of this permit until the Division has received this Certification and all required supporting documentation. Consequently, it should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Surface Water Protection Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial cer'tifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEERS CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. ............................................................... . North Carolina Professional Engineer's Seal w/signature & date CERTIFICATION COMMENTS OR DETAILS........................ ❑ Final ❑ Partial Comments: NC Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Wilmington Regional Office Phone: 910-796-7215 FAX: 910-350-2004 0 H cc 0 Z Z 0 a 0 CL a s Z % :a 0 LL Z a Application Number: j USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! I (to be completed by DWQ) v" vc(J c3 0 1. Owner/Permittee: i a. Town of Leland } Full Legal Name (company, municipality, HOA, utility, etc.) -- - - j1b. William B. Farris (Town Manager) Signing Official Name and Title (Please review 15A NCAC 2T.01 06 (b) for authorized i ng officialsl) ----.. __ --_ _ _ _... _..--- .- .- •-_-• _ - - ,1 c. The legal entity who will ow this system is: I_ _ ❑Individual ❑ Federal 0 MuniciPalityr ❑ State%C_o_u_nty ❑ Private Partnership ❑ Corporation ❑ Other specify. . _ �id.- 102 Town Hall Drive ,1e Leland Malling Address City If. NCli g. 28451 State Zip Code 910-371-0148 1 i. 910-371-1073 1 j. 1 Telephone Facsimile E-mail 2. ro►ect (Facility) Information: 2a. The Villages at Brunswick Forest East Village -Phase 1 12b. Brunswick Brief Project Name (permit will refer to this name) County Where Project is Located 3. Contact Person: 3a. David S. Hollis, PE, PLS Hanover Design Services P.A. Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 910-343-8002 �c. dhollis@hdsilm.com Phone Number ( E-mail 1. Project is ❑ New Modification (of an existing permit) If Modification, Permit No.: WQ 0028587 MOD �2. Owner is 0 Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) �a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) El Public Utility (Instruction C) ❑ Selling units (lots, townhomes, etc. - go to Item B(2h)) ❑ Homeowner Assoc./Developer (Instruction D) j3. Brunswick Countv Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Northeast Brunswick Regional WWTF I4b. NC 0086819 Name of WWTF WWTF Permit No. a. Town of Leland 5b. 8" KGravity c. Owner of Downstream Sewer Receiving Sewer Size I❑ Force Main Permit # of Downstream Sewer (Instruction E) 6_ The origin of this wastewater is check all that apply)_ ❑ Residential Subdivision ETRetail (Stores, shopping centers) 100 %Domestic/Commercial ❑ Apartments/Condominiums ❑ Institution % Industrial (attach ❑ Mobile Home Park ❑ Hospital ❑,School ❑Church description.) Restaurant ❑ Nursing Home (RO: contact your Regional Office ❑ Office ❑ Other (specify): Pretreatment staff) % Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: 18,182 gallons per day *Do not include future flows or previously permitted allocations 3. If the permitted flow is zero, indicate why: [] Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line II Flow has already been allocated in Permit No. II Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA 12/07 ;9. -Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for 1 the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in I Item 13(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use I data in accordance with 15A NCAC 2T .0114 (f). [4,920 GPD Lot 6 Grocery Store (49,170 sf 100GPD/1,000sf)]; [8,437GPD 1 Lot 6 Retail Stores (84,370 sf 100GPD/1,000 sf)]; [1,325 GPD Pharmacy (13,225 sf 100GPD/1,000sf)]; [1,500 GPD Lot 8 Restaurant Drive-Thru (30 space x 50 GPD)];[2,000 GPD Lot 8 Restaurant (50 seat x 40 GPD)] Total=18,182 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) - - - Size (inches) Length (feet) New Gravity or Additional F ----- -- - --- -- --- -- -- - - -- -_•-----Force _Main -------. 8 1,630 Gravity T ----------------- Q. +11. Summa...LLJ .-_ Pump Station Location ID _ (self chosen - as shown on plans/map for reference) Design Flow ! Operational Point Power Reliability Option Z (MGD) 1 GPM @TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length V` I 2 - portable generator w/MTS z 1" -Pump Station Location ID _ _ (self chosen - as shown on plans/map for reference) Flow `----- -_ Power Design Reliability Option i { (MGD) Operational Point 1 - permanent generator w/ATS; GPM @TDH + 2 - portable generator w/MTS i Force Main Size Force Main Length LL I �.. - IPump Station Location ID -_— — _ _ _ (self chosen - as shown on plans/map for reference) W I y `Power Reliability Option a Design Flow ` Y O P j(MGD) Operational Point 1 - permanent generator w/ATS; m 1 1 GPM @TDH , 2 - portable generator w/MTS Force Main Size Force Main Length 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? Yes vZNo If Yes, permit number of 2nd treatment facility I(RO - if "yes" to 6,12 please contact the Central Office PERCS Unit) 113. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force i Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as 7licable? Yes f] No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12/07 M '---._r14. Have the following ..__----------------------.._...--------------•--------._..---•--• p•------.......--------.._.._.._.._----I g permits/certifications been submitted forapproval for the system or project to be served?. Wetland/Stream Crossings - General Pbrmit or 401 Certification? ❑. Yes Q No [E�`N/A I ' Sedimentation and Erosion Control PlanZyes ❑ No Q N/A Stormwater? Zyes ❑ No [j N/A �15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: II and provide details . Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, —William B. Farris , attest that this application for The Villages at Brunswick Forest East Village -Phase 1 has been reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine nol to exceed $10,000 as well as civil penalties up -to $25 000 per violation. Signing Official Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS PPPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY Cn TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 Z aProfessional Engineer's Certification: (Signature of Design Engineer and Project Name) V 1, _David S. Hollis PE, PLS , attest that this application for_ The Villages at Brunswick Forest East Village -Phase 1 LL has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum W Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track (,) Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. David S. Hollis PE,PLS Professional Engineer Name 2b. Hanover Design Services P.A. Engineering Firm 2c. 1123 Floral Parkway Mailing Address ?d. Wilmington 2e. City ?9- 910-343-8002 i211. 910-343-9941 �21. Telephone Facsimile NC 2f. 28403 - - State Zip dhollis@hdsilm.com E-mail NC PE Seal, Signature & Date FTA 12/07 FORM WSCAS-12/07 40,�, oF WArl9Q WA1`ERSHED CLASSIFICATION ATTACHMENT > r FOR SEWER SYSTEMS Y A licaht Name ' Pro'ect Name Funston Land & Timber ,LLC The Villages at Brunswick Forest 1007 Evangeline Drive Leland, NC 28451 East Village -Phase 1 910-383-1425 Professional En ineer Name En' ineerin ' Firm Name David S. Hollis PE,PLS Hanover Dosign SorvioOG, P.A. 1123 Floral Parkway Wilmington NC, 28403 910-343-8002 Location ID Name of Waterbody' Count River Basin Waterbody Stream Index No. Waterbody Classification C2ommerciai piney Branch Brunswick Cape Fear 18-77-3-1 C•Sw ' If unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins. I certify that as a Registered Professional Engineer in the State of��"rF#='-=_=:-:===" •:'- North Carolina that I have diligently followed the Division's instructions ''"'_; °46gi!`'"$8 for classifying waterbodies and that the above classifications are j inclusive of the stated project, complete and correct to the best of my, knowledge �� �`� and belief. _.�:. -Y r_ N°= 'ii0 . -•®. i � ��_ �.fV�{%�: J � `. may, -, _ -- PE Seal, Signature and Date END OF FORM WSCAS-12/07 FORM: WSCAS-12/07 Page 1 of 1 -�.cJI Ot� �s11p COUNTY OF BRUNSWICK PUBLIC UTILITIES DEPARTMENT Jy May, 2, 2005 Mr. David Hewett, Town Manager Town of Leland 102 Town Hall Drive Leland, NC 28451 Re: Brunswick Forest Acceptance of Sewer Flow Northeast Brunswick Regional VVVVTP NPDES Permit No. NC 0086819 Dear Mr. Hewett: PO BOX 249 BOLIVIA, NC 28422 (910) 253-2657 (910) 253-4304 FAX We have received and reviewed your request for the proposed connection of Brunswick Forest, a single family subdivision and commercial area to the Town of Leland's sanitary sewer collection system (WQ 0018076). The sewer flow from this project is estimated to be 149,700 gallons per day to serve 300 single family homes, one 2 story restaurant, one 30,000 sq. ft office building and one 100,000 sq ft grocery store complex. This letter is hereby written notice of acceptance of the estimated daily sanitary sewer -flow for the above referenced project from the Town of Leland's sanitary sewer collection system into -the County's Northeast Brunswick Regional Wastewater System. The County will accept this flow for treatment; an estimated daily average daily flow of 149,700 of sanitary sewer only per the Fast Track Application for Gravity Sewers, Pump Stations and Force Mains dated March 10, 2005. The sewer flow from this project shall comply with the County's Sewer Use Ordinance at all times. If problems occur that may have a detrimental impact on the County's collection system and/or treatment facility, the Town shall notify the County's Public Utilities Department as soon as possible and provide a written record of the incident within fifteen (15) calendar days including an action plan to help prevent recurrence of the problem. If you have any questions or concerns regarding this correspondence please feel free to contact us. 'ncerely, Je Pierce, P.E. Director of Public Utilities Attachment cc: Marty Lawing, County Manager Donald Dixon, WRF Superintendent (NBWRF) Steve Hlastala, Wastewater Collection Superintendent David S. Hollis, P.E. Hanover Design Services