March 23, 2018
David A. Hollis, Town Manager
Town of Leland
102 Town Hall Drive
Leland, NC 28451
Subject: Permit No. WQ0028587 MODIFICATION
Town of Leland
Brunswick Forest Collection System
Wastewater Collection System Extension
Brunswick County
Dear Mr. Hollis:
MICHAEL S. REGAN
LIND.A CULPEPPER
a,.,,,,.. r n..,w,r
In accordance with your application received February 27, 2018 we are forwarding herewith Permit No.
WQ0028587 dated March 23, 2018 to the Town of Leland (Permittee) forthe construction and operation
upon certification of the subject wastewater collection system extension. This permit shall be effective
from the date of issuance until rescinded, shall void Permit No. WQ0028587 issued March 21, 2018, and
shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered
a part of this permit and is therefore incorporated therein by reference.
This modification adds 3,602 ft of 8-inch gravity sewer to serve 103 three -bedroom residences in Phase
9 Section 4 with a flow allocation of 21,630 gpd.
Please pay particular attention to the following conditions contained within this permit:
Special Conditions:
Condition 1.1: This permit shall become voidable unless the agreement between the Town of Leland
and Brunswick County forthe collection and final treatment of wastewater is in full force
and effect. [15A NCAC 02T.0304(h)]
Condition 1.2: Each pump station shall be clearly and conspicuously posted using a weatherproof sign
with a pump station identifying name/number, address, 24-Hour Emergency telephone
number, and name of the owner/operator of the sewer system/pump station and
instructions to call the number in the event of alarm activation or other emergency.
Simplex pump stations or vacuum sewer pits serving a single-family residence may have
a placard or sticker on the control panel in lieu of a sign. [15A NCAC 02T .0305(h)(2)]
- !Nothing Compares-.,_
127 Cardinal Drive Extension, Wilmington, North Carolina 28405
Phone: 910-796-7215\ Internet: www.deg.nc.gov
An Equal Opportunity \Affirmative Action Employer —Made in part by recycled paper
DocuSign Envelope ID. 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
Standard Conditions:
Condition 11.1: This permit shall not be automatically transferable; a request must be made and
approved.
Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained
in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system
permit issued to the Permittee.
Condition 11.13: If the Permittee/Applicant holds a system -side collection system operation,
maintenance and management permit (WQCS-prefix) from the Division, then the
following applies: For all newly constructed, modified and rehabilitated pump stations,
all equipment and components shall be sealed within a corrosion -resistant coating or
encasement to the extent practicable and equivalent to the minimum design criteria
unless the permittee can demonstrate it is not practicable or another form of corrosion
resistance is employed. [15A NCAC 02T .0108 (b)]
It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate
design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina
General Statute §143-215.6A through §143-215.6C, construction of additional or replacement
wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to
the licensing board.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to
request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This
request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General
Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC
27699-6714. Unless such demands are made, this permit shall be final and binding.
If you need additional information concerning this matter, please contact Dean Hunkele at (910) 796-7215
or via e-mail at Dean.Hunkele(@ncdenr.gov.
Sincerely,
EDocuSigned by:
s 6"
E3ABA14AC7DC434...
Morella Sanchez -King, Acting Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
Cc: Adam Grady, Hanover Design Services (via email)
Bill Pinnix, Brunswick County (via email)
WIRO, Water Quality Section — NE Brunswick Regional WWTF (NC0086819) Sewer Ext. File
Central Files, Water Quality Section
PERCS Unit (via email)
Permit No. WQ0028587 Page 2 of 15
DocuSign Envelope ID: 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
Environmental
Quality
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the
TOWN OF LELAND
BRUNSWICK COUNTY
for the construction and operation upon certification of approximately 3,602 linear feet of 8-inch gravity
sewer to serve 103 three -bedroom residences as part of the Phase 9 Section 4 project, and the discharge
of 21,630 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage
system, pursuant to the application received February 27, 2018, and in conformity with 15A NCAC 2T; the
Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1,
2000 as applicable; and other supporting data subsequently filed and approved by the Department of
Environmental Quality and considered a part of this permit.
"11D:
For the continued construction and operation upon certification of approximately 3,558 linear feet of 8-
inch gravity sewer to serve 58 three -bedroom residences as part of the Phase 1 Section 4B project, and
the discharge of 12,180 gallons per day of collected domestic wastewater into the Town of Leland's
existing sewerage system, pursuant to the application received February 26, 2018.
March 1. 2018 Modification (Version 4.5)
For the continued construction and operation upon certification of approximately 9,920 linear feet of 8-
inch gravity sewer; a 75—gallon per minute pump station with duplex pumps, on -site audible and visual
high water alarms, telemetry, and a permanent generator with automatic transfer switch or an
automatically activated stand-by bypass pump as well as approximately 2893 linear feet of 4-inch force
main to serve 169 three -bedroom residences as part of the Phase 5 Section B-2 project, and the discharge
of 35,490 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage
system, pursuant to the application received January 30, 2018.
Seotember 12, 2017 Modification (Version 4.4)
For the continued construction and operation upon certification of approximately 3,599 linear feet of 8-
inch gravity to serve 75 three -bedroom residences as part of the Phase 9 Section 5 project, and the
discharge of 15,750 gallons per day of collected domestic wastewater into the Town of Leland's existing
sewerage system, pursuant to the application August 18, 2017.
Permit No. WQ0028587 Page 3 of 15
DocuSign Envelope ID. 4489DE4F-5146-4C9D-8425-AAC7203D78C0
January 19, 2017 Modification (Version 4.3)
For the continued construction and operation upon certification of approximately 4,124 linear feet of 8-
inch and 1,195 linear feet of 10-inch gravity sewer; a 372—gallon per minute pump station (#7) with duplex
pumps, on -site audible and visual high water alarms, telemetry, and a permanent generator with
automatic transfer switch or an automatically activated stand-by bypass pump as well as approximately
2,210 linear feet of 5-inch force main to directly serve 88 three -bedroom residences and the discharge of
18,480 gallons per day of collected domestic wastewater plus flow from the system below and future
service areas;
For the continued construction and operation upon certification of approximately 4,815 linear feet of 8-
inch gravity sewer; a 63—gallon per minute pump station (#8) with duplex pumps, on -site audible and
visual high water alarms, telemetry, and a permanent generator with automatic transfer switch or an
automatically activated stand-by bypass pump as well as approximately 1,350 linear feet of 3-inch force
main to serve 112 three -bedroom residences and the discharge of 23,520 gallons per day of collected
domestic wastewater;
Both systems described above are associated with the Phase 9 Section 3 project discharging into the Town
of Leland's existing sewerage system, pursuant to the application received December 19, 2016 and
additional information received on January 11" and 18t", 2017.
September 14, 2016 Modification (Version 4.2)
For the continued operation of approximately 1,560 linear feet of 8-inch to serve 28 three -bedroom
single-family residences as part of the Phase 1 Section 5 project, and the discharge of 5,880 gallons per
day of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to
the application received August 10, 2016. This system was certified complete on January 5, 2017.
April 14, 2016 Modification (Version 4.1)
For the continued construction and operation upon certification of approximately 4,423 linear feet of fl-
inch and 154 linear feet of 12-inch gravity sewer to serve 80 three -bedroom single-family residences as
part of the Phase 3 Section 3 project, and the discharge of 16,800 gallons per day of collected domestic
wastewater into the Town of Leland's existing sewerage system, pursuant to the application received
March 11, 2016.
October 26, 2015 Modification (Version 4.0)
For the continued construction and operation upon certification of approximately 5,390 linear feet of 8-
inch gravity sewer, a 52-gallon per minute pump station with 1,210 linear feet of 4-inch force main to
serve 119 three -bedroom single-family residences as part of the Phase 5 Section B-1 project, and the
discharge of 24,990 gallons per day of collected domestic wastewater into the Town of Leland's existing
sewerage system, pursuant to the application received September 10, 2015. This system was certified
complete on January 17, 2018.
Permit No. WQ0028587 Page 4 of 15
DocuSign Envelope ID: 44B9DE4F-5146-4C9D-8425-AAC7203D78Co
August 3, 2015 Modification (Version 3.9)
For the continued construction and operation upon certification of approximately 6,147 linear feet of fl-
inch, 1,201 linear feet of 10-inch, and 538 linear feet of 12-inch gravity sewer; a 108-gallon per minute
pump station with 722 linear feet of 6-inch force main to serve 220 three -bedroom single-family
residences as part of the Phase 2 Section 4 project, and the discharge of 46,200 gallons per day of
collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the
application received July 9, 2015.
June 2, 2015 Modification (Version 3.8)
For the continued operation of approximately 4,534 linear feet of 8-inch and 1,326 linear feet of 12-inch
gravity sewer to serve 101 three -bedroom single-family residences and 30 duplex units as part of the
Phase 2 Section 3 project, and the discharge of 27,510 gallons per day of collected domestic wastewater
into the Town of Leland's existing sewerage system, pursuant to the application received April 22, 2015
and additional information received on June 1, 2015. This system was certified as complete on February
11, 2016.
January 15, 2015 Modification (Version 3.7)
For the continued construction and operation upon certification of approximately 3,217 linear feet of 8-
inch gravity sewer to serve 44 three -bedroom homes as part of the Phase 2 Section 5 (Tennyson Village)
project, and the discharge of 9,240 gallons per day of collected domestic wastewater into the Town of
Leland's existing sewerage system, pursuant to the application received December 11, 2014. This system
was certified as complete on June 15, 2017.
May 23, 2014 Modification (Version 3.6)
For the continued operation of approximately 4,965 linear feet of 8-inch gravity sewer; a 90—gallon per
minute pump station with duplex pumps, on -site audible and visual high water alarms, telemetry, and a
permanent generator with automatic transfer switch as well as approximately 2,090 linear feet of 4-inch
force main to serve 96 three -bedroom single—family residences as part of the Brunswick Forest Phase 1
Section 4 project, and the discharge of 20,160 gallons per day of collected domestic wastewater into the
Town of Leland's existing sewerage system, pursuant to the application received April 15, 2014. This
system was certified as complete on March 17, 2015.
December 19, 2013 Modification (Version 3.5)
For the continued operation of approximately 1,766 linear feet of 8-inch gravity sewer to serve 43 three -
bedroom single-family residences as part of the Brunswick Forest Phase 1 Section 6B project, and the
discharge of 9,030 gallons per day of collected domestic wastewater into the Town of Leland's existing
sewerage system, pursuant to the application received November 21, 2013. This system was certified as
complete on August 6, 2014.
October 9, 2013 Modification (Version 3.4)
For the continued operation of approximately 5,685 linear feet of 8-inch gravity sewer to serve 101 three -
bedroom single-family residences and 22 three -bedroom duplex units as part of the Brunswick Forest
Phase 2 Section 2 project, and the discharge of 25,830 gallons per day of collected domestic wastewater
into the Town of Leland's existing sewerage system, pursuant to the application received August 29, 2013
and additional information received on September 4, 2013. This system was certified as complete on
August 19, 2014.
Permit No. WQ0028587 Page 5 of 15
DocuSign Envelope ID. 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
March 6, 2013 Modification (Version 3.3)
Forthe continued construction and operation upon certification of approximately 208linearfeet of 8-inch
gravity sewer to serve a medical office on Lot 10 of the South Village commercial area as part of the South
Village Lot 10 project, and the discharge of 750 gallons per day of collected domestic wastewater into the
Town of Leland's existing sewerage system, pursuant to the application received January 24, 2013, and
additional information received on January 30, 2013.
March 21, 2012 Modification (Version 3.2)
For the continued operation of approximately 4,411 linear feet of 8-inch gravity sewer, to serve 87 three -
bedroom residences (18,270 gpd), 32 three -bedroom townhomes (6,720 gpd), and 4 buildings with a total
of 16 multi -family units (3,360 gpd) as part of the Brunswick Forest Phase 2B Section 1 project, and the
discharge of 28,350 gallons per day of collected domestic wastewater into the Town of Leland's existing
sewerage system, pursuant to the applications received March 5, 2012. This system was certified as
complete on March 24, 2014.
April 21, 2011 Modification (Version 3.1)
For the continued operation of approximately 679 linear feet of 8-inch gravity sewer, to serve 13 three -
bedroom residences (70 gpd/bedroom), as part of the Brunswick Forest Phase 1 Section 6A project, and
the discharge of 1,820 gallons per day of collected domestic wastewater into the Town of Leland's existing
sewerage system, pursuant to the applications received March 30, 2011. This system was certified as
complete on June 30, 2011.
February 13, 2009 Modification (Versions 2.9 and 3.0)
For the continued operation of approximately 4,765 linear feet of 12-inch gravity sewer, 13,696 linear feet
of 8-inch gravity sewer; a 450—gallon per minute pump station with duplex pumps, on -site audible and
visual high water alarms, telemetry, and on -site generator with automatic transfer switch with
approximately 9,805 linearfeet of 8-inch force main to serve 193 three -bedroom residences, maintenance
shed with wash bay (1,650 gpd), golf course restrooms (1,000 gpd), and a country club with food service
(7,440 gpd) as part of the Brunswick Forest Phase 3B & Country Club project, and the discharge of 50,620
(reduced from 79,570) gallons per day of collected domestic wastewater into the Town of Leland's existing
sewerage system, pursuant to the applications received January 26, and 27, 2009. This system was
certified complete on August 30, 2016.
February 6, 2009 Modification (Version 2.8)
For the continued operation of approximately 3,988 linear feet of 8-inch gravity sewer to 48 three -
bedroom residences and 72 two -bedroom residences as part of the Brunswick Forest Phase 1 Section 2
Village 2-A Sewer project, and the discharge of 20,160 (reduced from 34,560) gallons per day of collected
domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application
received January 9, 2009. This system was certified as complete on May 4, 2009.
January 30, 2009 Modification (Version 2.7)
For the continued operation of approximately 13,192 linear feet of 8-inch gravity sewer, approximately
1,564 linear feet of 10-inch gravity sewer, approximately 2,531 linear feet of 12-inch gravity sewer; a 550—
gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms,
telemetry, on -site generator with automatic transfer switch with approximately 10,325 linear feet of 10-
inch force main to serve 324 single-family three -bedroom lots as part of the Brunswick Forest Phase 5A
and Phase 5 project, and the discharge of 68,040 (reduced from 116,640) gallons per day of collected
domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application
received December 22, 2008. This system was certified as complete on July 13, 2015.
Permit No. WQ0028587 Page 6 of 15
DocuSign Envelope ID: 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
October 17, 2008 Modification (Version 2.6)
Forthe continued operation of approximately4,607 linear feet of 8-inch gravity sewerto serve as a gravity
sewer outfall or interceptor line for future upstream or tributary sewer systems as part of The Villages at
Brunswick Forest project with no additional discharge of collected domestic wastewater into Town of
Leland's existing sewerage system, pursuant to the application received September 26, 2008. This system
was certified as complete on December 8, 2008 & updated May 4, 2009.
August 1, 2008 Modification (Version 2.5)
For the continued operation of approximately 599 linear feet of 8-inch gravity sewer to serve a 3,511
gallons per day medical office building as part of the South Village Phase-1 project, and the discharge of
3,511 gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage
system, pursuant to the application received June 19, 2008. This system was certified as complete on
May 4, 2009.
July 18, 2008 Modification (Version 2.4)
Forthe continued operation of approximately 1,630 linear feet of 8-inch gravity sewer to serve a 49,170
sf Grocery Store (4,920 gpd), 84,370 sf of Retail Space with no food services (8,437 gpd), a 13,225 sf
Pharmacy (1,325 gpd), a 30 space Restaurant Drive-Thru (1,500 gpd) and a 50 seat Restaurant (2,000 gpd)
as part of the East Village Phase-1 project, and the discharge of 18,182 gallon per day of collected
domestic wastewater into the Town of Leland's existing sewerage system, pursuant to the application
received June 19, 2008. This system was certified as complete on September27, 2011.
October 12, 2007 Modification (Version 2.3)
For the continued operation of approximately 1,174 linear feet of 8-inch gravity sewer to serve 62 three -
bedroom and 10 two -bedroom residences as part of the Phase 1 Section 2 Village 4-A project, and the
discharge of 14,420 (reduced from 24,720) gallons per day of collected domestic wastewater into the
Town of Leland's existing sewerage system, pursuant to the application received September 18, 2007.
This system was certified as complete on July 31, 2008 and updated May 8, 2009.
September 7, 2007 Modification (Version 2.2)
For the continued operation of approximately 2,952 linear feet of 8-inch gravity sewer to serve 72 three -
bedroom residences as part of the Phase 1 Section 2 Village 1-A project, and the discharge of 15,120
(reduced from 25,920) gallons per day of collected domestic wastewater into the Town of Leland's existing
sewerage system, pursuant to the application received July 25, 2007. This system was certified complete
on July 31, 2008.
June 8, 2007 Modification (Version 2.1)
For the continued operation of approximately 1,393 linear feet of 8-inch gravity sewer to serve Lots 1 & 2
for a bank with 10 employees (250 gpd) and an unspecified development on the other (will require
allocation to be added prior to connection) as part of the East Village Commercial Center project, and the
discharge of 250 gallons per day of collected domestic wastewater into the Town of Leland's existing
sewerage system, pursuant to the application received May 16, 2007. This system was certified as
complete on December 6, 2007.
April 20, 2007 Modification (Version 2.0)
For the continued operation of approximately 5,065 linear feet of 8-inch gravity sewer to serve 94 three -
bedroom single-family residences as part of the Brunswick Forest Phase 1 Section 3 project, and the
discharge of 19,470 (reduced from 33,840) gallons per day of collected domestic wastewater into the
Town of Leland's existing sewerage system, pursuant to the application received March 29, 2007. This
system was certified as complete on August 6, 2008.
Permit No. WQ0028587 Page 7 of 15
DocuSign Envelope ID. 4489DE4F-5146-4C9D-8425-AAC7203D78C0
April 13, 2007 Modification (Version 1.9)
For the continued operation of approximately 5,126 linear feet of 8-inch gravity sewer to serve 56 three -
bedroom single-family residences and 30 three -bedroom & 30 two -bedroom townhomes as part of the
Brunswick Forest Phase 6 Sections 1-B & 2 project, and the discharge of 22,260 (reduced from 38,610)
gallons per day of collected domestic wastewater into the Town of Leland's existing sewerage system,
pursuant to the application received March 9, 2007. This system was certified as complete on November
30, 2007.
December 22, 2006 Modification (Version 1.8)
For the continued operation of approximately 13,874 linear feet of 8-inch gravity sewer; a 387—gallon per
minute pump station with duplex pumps, on -site audible and visual high water alarms, telemetry, and on -
site generator with automatic transfer switch; as well as approximately 3,520 linear feet of 6-inch force
main to serve 193 three -bedroom residences as part of the Brunswick Forest Phase 1 Section 2 project,
and the discharge of 40,530 (reduced from 69,480) gallons per day of collected domestic wastewater into
the Town of Leland's existing sewerage system, pursuant to the application received December 1, 2006.
This system was certified as complete on May 4, 2009.
October 27, 2006 Modification (Version 1.6)
For the continued operation of approximately 1,008 linear feet of 8-inch gravity sewer to serve future
development including a sales center & wellness facility in Brunswick Forest Phase 6 Section 1-A as part
of the Brunswick Forest project and the discharge of 800 gallons per day of collected domestic wastewater
into the Town of Leland's existing sewerage system, pursuant to the application received September 15,
2006. This system was certified as complete on June 15, 2007.
May 26, 2006 Modification (Version 1.5)
For the continued operation of approximately 5,926 linear feet of 8-inch gravity sewer; a 380—gallon per
minute pump station with duplex pumps, on -site audible and visual high water alarms, telemetry, and on -
site generator with automatic transfer switch; as well as approximately 3,915 (increased from 2,821 feet
per modification issued November 3, 2006) linear feet of 5-inch force main to serve 149 three -bedroom
residences as part of the Jefferson Landing at Brunswick Forest Phase 2 (aka Phase 1 Section 1-B) project,
and the discharge of 31,290 (reduced from 53,640) gallons per day of collected domestic wastewater into
the Town of Leland's existing sewerage system, pursuant to the application originally received April 24,
2006 and subsequent modification request received September 25, 2006. This system was certified as
complete on March 27, 2007.
April 7, 2006 Modification (Version 1.4)
For the continued operation of approximately 793 linear feet of 10-inch, and 2,329 (reduced from 3,830)
linear feet of 12-inch gravity sewer to serve as a gravity sewer outfall or interceptor line for future
upstream or tributary sewer systems as part of the Brunswick Forest Phase 3A project with no additional
discharge of collected domestic wastewater into the Town of Leland's existing sewerage system, pursuant
to the application received February 16, 2006. This system was certified as complete on March 15, 2007.
March 10, 2006 Modification (Version 1.3)
For the continued operation of approximately 6,741 linear feet of 8-inch gravity sewer to serve 131 three -
bedroom residences as part of the Jefferson Landing at Brunswick Forest Phase 1 (aka Phase 1 Section
1-A) project, and the discharge of 27,510 (reduced from 47,160) gallons per day of collected domestic
wastewater into the Town of Leland's existing sewerage system, pursuant to the application received
February 14, 2006, This system was certified as complete on December 22, 2006.
Permit No. WQ0028587 Page 8 of 15
DocuSign Envelope ID. 4489DE4F-5140-4C9D-8425-AAC7203D78C0
July 21, 2005 Modification (Version 1.2)
For the continued operation of approximately 25 linear feet of 8-inch and 3,290 linear feet of 12-inch
gravity sewer to serve as a gravity sewer outfall or interceptor line for future development upstream of
the previously approved sewer listed below as part of the Brunswick Forest Phase 2 project, and with no
additional discharge of collected wastewater into the Town of Leland's existing sewerage system,
pursuant to the application received June 15, 2005. This system was certified as complete on December
8, 2008.
March 24, 2005 Original Permit (Versions 1.0 & 1.1)
For the continued operation of approximately 868 linear feet of 8-inch, 3,414 linear feet of 10-inch, and
3,141 linear feet of 12-inch gravity sewer; a 1500—gallon per minute pump station with duplex pumps, on -
site audible and visual high water alarms, telemetry/autodialer, and on -site generator with automatic
transfer switch; as well as approximately 20,650 total linear feet of 10-inch force main (dual force mains)
to serve this large residential and commercial development as part of the Brunswick Forest Phase 1
project with no discharge of wastewater into the Town of Leland's existing sewerage system, pursuant to
the application received March 11, 2005. This system was certified as complete on March 15, 2007.
From the original permit 25,257 god of commercial flow allocation remains in reserve from the October
17, 2008 modification.
This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified
conditions and limitations contained therein.
Permit Number: WQ0028587
Issued Today: March 23, 2018
DocuSigned by.
E3ABA14AC7DC434...
Morella Sanchez -King, Acting Regional Supervisor
Wilmington Regional Office
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
By Authority of the Director and The Environmental Management Commission
Permit No. WQ0028587 Page 9 of 15
DocuSign Envelope ID. 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
SUPPLEMENT TO PERMIT COVER SHEET
TOWN OF LELAND is hereby authorized to:
Construct, and then operate upon certification the aforementioned wastewater collection extension. The
sewage and wastewater collected by this system shall be treated in the NE Brunswick Regional
Wastewater Treatment Facility in accordance with Permit Number NC0086819.
Permitting of this project does not constitute an acceptance of any part of the project that does not meet
15A NCAC 2T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted
February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned
herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed
Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -
constructed project meets the appropriate design criteria and rules.
Construction and operation is contingent upon compliance with the Standard Conditions and any Special
Conditions identified below.
SPECIAL CONDITIONS
1. This permit shall become voidable unless the agreement between the Town of Leland and Brunswick
County for the collection and final treatment of wastewater is in full force and effect. [15A NCAC
02T.0304(h))
2. Each pump station shall be clearly and conspicuously posted using a weatherproof sign with a pump
station identifying name/number, address, 24-Hour Emergency telephone number, and name of the
owner/operator of the sewer system/pump station and instructions to call the number in the event
of alarm activation or other emergency. Simplex pump stations or vacuum sewer pits serving a single-
family residence may have a placard or sticker on the control panel in lieu of a sign. [15A NCAC 02T
.0305(h)(2)]
II. STANDARD CONDITIONS
1. This permit shall not be transferable. In the event there is a desire for the wastewater collection
facilities to change ownership, or there is a name change of the Permittee, a formal permit request
shall be submitted to the Division accompanied by documentation from the parties involved, and
other supporting materials as may be appropriate. The approval of this request shall be considered
on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)]
2. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum
Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for
the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and
other supporting materials unless specifically mentioned herein. [15A NCAC 02T.01101
Permit No. WQ0028587 Page 10 of 15
DocuSign Envelope ID: 44B9DE4F-5146-4C9D-8425-AAC7203D78C0 .
3. This permit shall be effective only with respect to the nature and volume of wastes described in the
application and other supporting data. [15A NCAC 02T .0110]
4. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual
permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]
a. The sewer system shall be effectively maintained and operated at all times to prevent discharge
to land or surface waters, and to prevent any contravention of groundwater standards or surface
water standards.
b. A map of the sewer system shall be developed and shall be actively maintained.
c. An operation and maintenance plan including pump station inspection frequency, preventative
maintenance schedule, spare parts inventory and overflow response has been developed and
implemented.
d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365
days per year). Pump stations that are connected to a telemetry system shall be inspected at
least once per week.
e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are
documented.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance
with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina
General Statute §143-215.1C.
h. A Grease Control Program is in place as follows:
1. For public owned collection systems, the Grease Control Program shall include at least
biannual distribution of educational materials for both commercial and residential users and
the legal means to require grease interceptors at existing establishments. The plan shall also
include legal means for inspections of the grease interceptors, enforcement for violators and
the legal means to control grease entering the system from other public and private satellite
sewer systems.
2. For privately owned collection systems, the Grease Control Program shall include at least bi-
annual distribution of grease education materials to users of the collection system by the
permittee or its representative.
3. Grease education materials shall be distributed more often than required in Parts (1) and (2)
of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows.
i. Right-of-ways and easements shall be maintained in the full easement width for personnel and
equipment accessibility.
j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three
years with exception of the map, which shall be maintained for the life of the system.
Permit No. WQ0028587 Page 11 of 15
DocuSign Envelope ID. 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
5. Noncompliance Notification:
The Permittee shall report by telephone to a water resources staff member at the Wilmington
Regional Office, telephone number (910) 796-7215, as soon as possible, but in no case more than 24
hours or on the next working day, following the occurrence or first knowledge of the occurrence of
either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any SSO and/or spill over 1,000 gallons; or
c. Any SSO and/or spill, regardless of volume, that reaches surface water
Voice mail messages or faxed information is permissible, but this shall not be considered as the initial
verbal report. Overflows and spills occurring outside normal business hours may also be reported to
the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300.
Persons reporting any of the above occurrences shall file a spill report by completing and submitting
Part I of Form CS-SSO (or the most current Division approved form) within five days following first
knowledge of the occurrence.
This report must outline the actions taken or proposed to be taken to ensure that the problem does
not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed
to show that the SSO was beyond control. [G.S. 143-215.1C(al)]
6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface waters of the State. [15A NCAC 02T.0108(b)]
Upon completion of construction and prior to operation of these permitted facilities, the completed
Engineering Certification form attached to this permit shall be submitted with the required supporting
documents to the address provided on the form. A complete certification is one where the form is
fully executed and the supporting documents are provided as applicable. Any wastewater flow made
tributary to the wastewater collection system extension prior to completion of this Engineer's
Certification shall be considered a violation of the permit and shall subject the Permittee to
appropriate enforcement actions.
If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles
of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately
filed with the applicable County's Register of Deeds office shall be submitted with the certification.
A complete certification is one where the form is fully executed and the supporting documents are
provided as applicable. Supporting documentation shall include the following:
a. One copy of the project construction record drawings (plan & profile views of sewer lines & force
mains) of the wastewater collection system extension. Final record drawings should be clear on
the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are
marked up or annotated with after construction information and show required buffers,
separation distances, material changes, etc.
Permit No. WQ0028587 Page 12 of 15
DocuSign Envelope ID: 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
b. One copy of the supporting pump station design calculations (selected pumps, system curve,
operating point, buoyancy calculations, and available storage if portable generator(s) or storage
greater than longest past three year outage reliability option selected) for any pump stations
permitted as part of this project.
c. Changes to the project that do not result in non-compliance with this permit, regulations, or the
Minimum Design Criteria should be clearly identified on the record drawings, on the certification
in the space provided, or in written summary form.
Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in
non-compliance with this permit (including pipe length increases of 10% or greater, increased flow,
pump station design capacity design increases of 5% or greater, and increases in the number/type of
connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to
the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit.
Please note that variances to the Minimum Design Criteria should be requested and approved during
the permitting process prior to construction. After -construction requests are discouraged by the
Division and may not be approved, thus requiring replacement or repair prior to certification &
activation. [15A NCAC 02T .0116]
8. Gravitysewers installed greaterthan ten percent belowthe minimum required slope perthe Division's
Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until
corrected. If there is an unforeseen obstacle in the field where all viable solutions have been
examined, a slope variance can be requested from the Division with firm supporting documentation.
This shall be done through a permit modification with fee. Such variance requests will be evaluated
on a case -by -case basis. Resolution of such request shall be evident priorto completing and submitting
the construction certification. [ 15A NCAC 02T.0105(n)]
9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of
the wastewater collection facilities. [15A NCAC 02T .0116]
10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's
Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design
Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as
applicable; and other supporting materials may subject the Permittee to an enforcement action by
the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C,
construction of additional or replacement wastewater collection facilities, and/or referral of the North
Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T
.0108(b-c)]
11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including those
as may be required by this Division, such as the construction of additional or replacement facilities.
[15A NCAC 02T .0110; 15A NCAC 02T .0108(b)]
12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes,
rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local
government agencies which have jurisdiction or obtaining other permits which may be required by
the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)]
Permit No. WQ0028587 Page 13 of 15
DocuSign Envelope ID. 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
13. If the Permittee/Applicant holds a system -side collection system operation, maintenance and
management permit (WQCS-prefix) from the Division, then the following applies: For all newly
constructed, modified and rehabilitated pump stations, all equipment and components shall be sealed
within a corrosion -resistant coating or encasement to the extent practicable and equivalent to the
minimum design criteria unless the permittee can demonstrate it is not practicable or another form
of corrosion resistance is employed. [15A NCAC 02T .0108 (b)]
Permit No. WQ0028587 Page 14 of 15
DocuSign Envelope ID: 44B9DE4F-5146-4C9D-8425-AAC7203D78C0
FAST TRACK SEWER ENGINEERING CERTIFICATION
PERMITTEE:
Town of Leland
PERMIT #:
WQ0028587
PROJECT:
Brunswick Forest Phase 9 Section 4
ISSUE DATE:
March 23, 2018
COUNTY:
Brunswick
This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of
this permit until the Division has received this Certification and all required supporting documentation.
Consequently, it should be submitted in a manner that documents the Division's receipt. Send the
required documentation to the Wilmington Regional Supervisor, Water Quality Section at the address at
the bottom.
Any wastewater flow made tributary to the wastewater collection system extension prior to completion
of this Certification shall be considered a violation of the permit and shall subject the Permittee to
appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up
until a final certification is received. A Final Certification shall be a complete set of record drawings and
design calculations regardless of whether partials have been submitted.
PERMITTEE'S CERTIFICATION
I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant
to the applicable standards & requirements, the Professional Engineer below has provided applicable
design/construction information to the Permittee, and the Permittee is prepared to operate & maintain
the wastewater collection system permitted herein or portions thereof.
Printed Name, Title Signature
ENGINEERS CERTIFICATION
Date
I, , as a duly registered Professional Engineer in the State of North Carolina,
having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the
project name and location as referenced above for the above Permittee hereby state that, to the best of
my abilities, due care and diligence was used in the observation of the construction such that the
construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the
Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12,1996
as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and
Force Mains adopted June 1, 2000 as applicable; and other supporting materials.
North Carolina Professional Engineer's Seal w/signature & date
❑ Final ❑ Partial
Certification Comments/Qualifiers:
NC DWR —Water Quality Regional Operations Section 127 Cardinal Drive Extension Wilmington, NC 28405
Wilmington Regional Office Phone: 910-796-7215 FAX: 910-350-2004
Central Files: APS _ SWP
2/28/2018
Permit Number WQ0028587 Permit Tracking Slip
Status Project Type
Program Category In review Major modification
Nnn-discharge
Permit Type
Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions
Primary Reviewer
dean.hunkele
Coastal SVVRuIe
Permitted Flow
606,473
Version Permit Classification
Z09 Individual
Permit Contact Affiliation
Facility
Major/Minor Region
Facility Name Wilmington
Brunswick Forest Collection System Minor
Location Address
Facility Contact Affiliation
County
Brunswick
Owner
Owner Type "
Owner Name
Government - Municipal
Town of Leland
Owner Affiliation
David A. Hollis
PE
102 Town Hall Dr
Dates/Events Leland NC 28451
Scheduled
Orig Issue App Received Draft Initiated Issuance
3,124/2005 2/27/2018
Regulated Activities.
DWR ;
State of North Carolina
Department of Environmental Quality
Division of Water Resources
Division of Water Resources
15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
FTA 04-16 & SUPPORTING DOCUMENTATION
Application Numbe{.""(. be completed by DwR)
All items must be completed or the application will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Town of Leland (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ® Municipal ❑ Other
3. Signature authority's name: David A. Hollis. P.E. per 15A NCAC 02T .0106(b)
Title: Town Manager
4. Applicant's mailing address: 102 Town Hall Drive
City: Leland State: NC Zip: 28451-
5. Applicant's contact information:
Phone number. 210 371-0148 Email Address: dhollis@townofleland.com
U. PROJECT INFORMATION:
1. Project name: Brunswick Forest Phase 9 Section 4
2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project
If a modification, provide the existing permit number: W00028587 and issued date:
If new construction but part of a master plan, provide the existing permit number: WQ00_
3. County where project is located: Brunswick
4. Approximate Coordinates (Decimal Degrees): Latitude: 34.173693' Longitude:-78.044403'
5. Parcel ID (if applicable): _
(or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: Adam H. Grady, PE
Firm: Hanover Design Services, PA
Mailing address: 1123 Floral Pazkwav
City: Wilmington
Phone number: 210 343-8002
License Number: 43166
RECEIVEDINCDENRIDWR
State: NC Zip: 28403-_
VEB 21 Z0lt
Email Address: agrady(andsihn.com Regionai
Water quality
secon
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: Operations gTonal Office
Wilmington Re
1. Facility Name: Northeast Brunswick Regional W WTF Permit Number: NCO086819
Owner Name: Brunswick County
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than W WTF):
I. Permit Number(s): W00028587 Downstream (Receiving) Sewer Size: 10 inch
System Wide Collection System Permit Number(s) (if applicable): WQCS_
Owner Name(s): Town of Leland
FORM: FTA 04-16 Page 1 of 5
VI. GE. NERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑No ®N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes ❑No ®N/A
If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM:_HOA) been attached?
❑ Yes ❑No ®N/A
4. Origin of wastewater: (check all that apply):
® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Commercial % Commercial
_ % Industrial (See 15A NCAC 02T _0103 (20))
Is there a Pretreatment Program in effect?, ❑ Yes ❑ No
6. Has a flow reduction been.approved under 15A NCAC 02T .0114(t)? ❑ Yes ®No
➢ If Yes, provide a copy of flow reduction approval letter
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(f))
Daily Design Flow a,b
No. of Units
Flow
Residential
210 gal/day
103
21,630 GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD ,
gal/
GPD
Total
21,630 GPD
a See 15A NCAC 02T .0114(b); (d), (e)(1) and (OM for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be
'determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 21,630 GPD (per 15A NCAC 02T .0114)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Number:
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain):
FORM: FTA 04-16 Page 2 of 5
VH. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
8
3,602
C900 (DR18)
➢ Section lI &III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity:sewer(s)
➢ ' Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains):
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees)': Latitude: 0Longitude: -
3. Design flow of the pump station: millions gallons per day (firm capacity)
4. Operational .point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) Length (feet) Material
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(1)(C)
or
0 Portable pumping unit with plugged emergency pump connection and telemetry- 15A NCAC 02T .0305(h)(1)(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by`the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)):
1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g)
15A NCAC 02T.0305(fl contains minimum separations that shall be provided for sewer systems:
® Yes [—]No
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below vertical
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer
18 inches
Reclaimed water lines horizontal - reclaimed over sewer
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water
100 feet
**Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water or tide elevation and wetlands see item IX.2
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any'building foundation
5 feet
Any basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade vertical
36 inches
➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved.
➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webnage
➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No
➢ See the Division's draft separation requirements for situations where separation cannot be meet
➢ No variance is required if the alternative design criteria specified is utilized in design and construction
➢ As built documents should reference the location of areas effected
3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes [-]No
➢ This would include Trout Buffered Streams per 15A NCAC 213.0202
4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No
➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters
➢ Information can be obtained from the 401 & Buffer Permitting Branch
5. Does project comply with 15A NCAC 02T.0105(c)(6)' (additional permits/certifications)?
® Yes ❑ No
Per 15A NCAC 02T.0105(c)(6), :directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes 0 No
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections
documented ;per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02L the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
® Yes 0 No
If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for
review. Approval of the request is required prior to submittal of the Fast Track Application and supportins documents.
2. Professional Engineer's Certification:
attest that this application for
(Professional Engineer's name from Application Item III.1.)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering,calculations; and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifie''s that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — withIn General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false .
statement, representation, or certification in an application package shall be uilt of a Class 2 misdemeanor, which may
y pp� P g g Y Y
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal signature, and date:
g g CAR0
,�, o oFEssroy,.y
2-Q SEALTr'
43166
A
3. Applicant's Certification per 15A NCAC 02T .0106 (b):
ek A,. 4AV. sF BE liouan AlanA*0C ', attest that this application for
(Signature Authority's name & title from Application Item I.3.)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject .to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition
of this permit be violated. I also understand that if all required parts of this application package are not completed and that if
all required supporting information and attachments are not included, this application package will be returned to me as
incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in'any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to'$25,000 per violation.
Signature: Date:
FORM: FTA 04-16 Page 5 of 5
1
State of North Carolina
_ A Department of Environmental Quality
r�i.libo of \Va1er Aesourccs Division of Water Resources
Flow Tracking/Acceptance for Sewer Extension Applications
(FTSE 04-16)
Entity Requesting Allocation: Town of Leland
Project Name for which flow is being requested: Brunswick Forest Ph 9 Sec 4-Park West
More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater. flow.
I. Complete this section only if, you are the, owner of the wastewater treatment plant.
a. WWTP Facility Name: NORTHEAST BRUNSWICK
b. WWTP Facility Permit #: WQ .0086819 ,
All. flows are in MGD
c.
WWTP facility's permitted flow
2.475
d.,
Estimated obligated flow not yet tributary to the WWTP
2.323
e.
WWTP facility's actual avg. flow
1.850
f
Total flow for this specific request
0.02163
g.
Total actual and obligated flows to the facility
4.1.94
h.
Percent of permitted flow used
169%
II. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
(B)
(C)
(D)=(B+C) (E)=(A-D)
Design
Obligated,
Pump
Average Daily
Approx.
Not Yet
Total Current
Station
Firm Flow* *
Current Avg.
Tributary
Flow Plus
(Name or
Capacity, *, (Firm / pt),
Daily Flow,
Daily Flow,
Obligated Available
Number)
MGD MGD
MGD
MGD
Flow Capacity***
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the, pump station divided by a peaking
factor (pi) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer):
Downstream Permit Number:
Page 1 of 6
FTSE 04-16
III. Certification Statement: .
I Ann B. Hardy, County Manager certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation of
the planned improvements identified in the planning assessment where applicable. This analysis
has been performed in accordance with local established policies and procedures using the best
available data. This certification applies to those items listed above in Sections I and II plus all
attached planning assessment addendums for which I am the responsible party. Signature of this
form indicates acceptance of this wastewater flow.
IJ,, 6. d 6L,
Signing Official Signature
Approved as to Form.
Assam unty Attorney
Z3-1$
Date
Page 2 of 6
FTSE 04-16
DWR State of North Carolina
Department of Environmental Quality
Division of Water Resources
Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications
(FTSE 04-16)
Entity Requesting Allocation: Brunswick Forest
Project Name for which flow is being requested: Brunswick Forest Phase 9 Section 4
More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater. j1ow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name:
b. WWTP Facility Permit #:
c. WWTP facility's permitted flow
d. Estimated obligated flow not yet tributary to the WWTP
e. WWTP facility's actual avg. flow
f. Total flow for this specific request
g. Total actual and obligated flows to the facility
h. Percent of permitted flow used
All flows are in MGD
II. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
Design
Pump Average Daily
Station Firm Flow**
(Name or Capacity, * (Firm / pf),
Number) MGD MGD
(B)
Approx.
Current Avg.
Daily Flow,
MGD
(C)
Obligated,
Not Yet
Tributary
Daily Flow,
MGD
(D)=(B+C)
Total Current
Flow Plus
Obligated
Flow
(E)m(A-D)
Available
Capacity***
#28 BF 0.525 0.210
0.0
0.116
0.116
0.094
427BF 0.672 0.268
0.0042
0.079
0.084
0.184
#18BF 2.160 0.864
0.180
0.292
0.472
0.392
#1MG 0.625 0.250 0.195 0.313 0.509 -0.259
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pi) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the W WTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer): TptAffj pt LeIAND
Downstream Permit Number: _ W Q r S 00 3 33
Page I of 6
FTSE 04-16
State of North Carolina
Department of Environmental Quality
Division of Water Resources
Dlvislon of water Resources Flow Tracking/Acceptance for Sewer Extension Applications
(FTSE 04-16)
Entity Requesting Allocation: Brunswick Forest
Project Name for which flow is being requested: Brunswick Forest Phase 9 Section 4
More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant
a. WWTP Facility Name:
b. WWTP Facility Permit
c. WWTP facility's permitted flow
d. Estimated obligated flow not yet tributary to the WWTP
e. WWTP facility's actual avg. flow
f. Total flow for this specific request
g. Total actual and obligated flows to the facility
h. Percent of permitted flow used
All flows are in MGD
Il. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
(B)
(C)
(D)==(B+C)
(E)�(A-D)
Design
Obligated,
Pump
Average Daily
Approx.
Not Yet
Total Current
Station
Firm
Flow**
Current Avg.
Tributary
Flow Plus
(Name or
Capacity, *
(Firm / pf),
Daily Flow,
Daily Flow,
Obligated
Available
Number)
MGD
MGD
MGD
MGD
Flow
Capacity***
# 3 Mag.
1.670
0.668
0.576
0.530
1.106
-0.438
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pf) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer): Town of Leland
Downstream Permit Number: WQCS00333
Page 1 of 6
FTSE 04-16
III. Certification Statement:
I David A. Hollis certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation of
the planned improvements identified in the planning assessment where applicable. This analysis
has been performed in accordance with local established policies and procedures using the best
available data. This certification applies to those items listed above in Sections I and II plus all
attached planning assessment addendums for which I am the responsible parry. Signature of this
form indicates acceptance of this wastewater flow.
Signing Official
Date
4V
Page 2 of 6
FTSE 04-16
PLANNING ASSESSMENT ADDENDUM (PAA)
Submit a planning assessment addendum for each pump station listed in Section H where Available
Capacity is < 0.
Pump Station (Name or Number):
Given that:
a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for
1.42 % and -0.259 MGD of the Available Capacity (E) in Pump Station
# 1 In front of Magnolia ; and that
b.
C.
Greens
The rate of activation of this obligated, not yet tributary capacity is currently approximately
0.03 8 MGD per year; and that
A funded Capital Project that will provide the required planned capacity, namely
US 17 Corridor Force Main is in design or under construction with
planned completion in 2018/2019 Budget ; and/or
d. The following applies:
The Town of Leland has issued a notice to proceed to TA Loving company to start working
on the installinton and construction of a 10 inch and 16inch sewer forcemain that will
transfere sewer from the 17 corridor and will flow into the Towns Lift Station 410 which
will bypass Lift Station # 1 and Lift Station # 3 and flow directly to the Northeast Regional
Treatment Plant.
The construction is to start in Feburary 2018
Therefore:
Given reasonably expected conditions and planning information, there is sufficient justification to
allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the
system infrastructure.
I understand that this does not relieve the collection system owner from complying with G.S. 143-
215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste
disposal system.
Signing Official
01
C]
Page 3 of 6
FTSE 04-16
PLANNING ASSESSMENT ADDENDUM (PAA)
Submit a planning assessment addendum for each pump station listed in Section R where Available
Capacity is < 0.
Pump Station (Name or Number):
Given that:
a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for
1.22 % and-4438 MGD of the Available Capacity (E) in Pump Station
# 3 Magnolia Greens ; and that
b. The rate of activation of this obligated, not yet tributary capacity is currently approximately
0.03 8 MGD per year; and that
c. A funded Capital Project that will provide the required planned capacity, namely
US 17 Corridor Force Main is in design or under construction with
planned completion in 2018/2019 Budget ; and/or
d. The following applies:
The Town of Leland has issued a notice to proceed to TA Loving company to start working
on the installinton and construction of a 10 inch and 16inch sewer forcemain that will
transfere sewer from the 17 corridor and will flow into the Towns Lift Station # 10 which
will bypass Lift Station # 1 and Lift Station # 3 and flow directly to the Northeast Regional
Treatment Plant.
The construction is to start in Feburary 2018
Therefore:
Given reasonably expected conditions and planning information, there is sufficient justification to
allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the
system infrastructure.
I understand that this does not relieve the collection system owner from complying with G.S. 143-
215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste
disposal system.
Signing Official
Page 3 of 6
FTSE 04-16
i" I". tM I 10 r(ft 12 MA i': 1 1,111AN-N-11111121 I I! I
Brunswick Forest, Phase 9, ,Section 4
Located in the Town of Leland, Brunswick County, North Carolina
Prepared for:
Funston Land & Timber, LLC
1007 Evangeline Drive
Leland, NC 28451
910-383-1425
Owner:
Funston Land & Timber, LLC
1007 Evangeline Drive
Leland, NC 28451
910-383-1425
PROJECT DESCRIPTION —
This project is for the construction of a new residential community of 103 single-family
homes on an existing tract in the previously approved development of "Brunswick
Forest" off of existing Brunswick Forest Parkway in the Town of Leland, Brunswick
County, NC. The proposed subdivision has been designed and planned to comply with all
the Town's required setbacks and technical standards for construction.
Sewer flows will drain into an existing public 8" gravity collector in Green Spring Blvd.
All runoff will drain into proposed storm sewers and into proposed stormwater wet
retention / detention pond.
For more details and further explanation of the scope and specifics of this proposed
development, please refer to the submitted plans prepared by Hanover Design Services.
MOM
15,750
SnmstA ch Foros� fl are 9 Sec a, 4
to I
T)x� = FebMar-,� W I F
F %AIARFme MMARTFP I ITII Q PI ANRWFWPMT" -Mnglp wer?-MN 17 r