Subject: NOTICE OF DEFICIENCY
NOD-2019-PC-0183
Compliance Evaluation Inspection
Town of Woodland
Wastewater Irrigation System
Permit Number WQ0004910
Northampton County
On August 15, 2019, Rick Trone, Zach Thomas, and Josh Brigham of the Raleigh Regional Office
conducted a compliance evaluation inspection of the wastewater irrigation system for Town of Woodland.
The purpose of this inspection was to ensure compliance with the subject permit. During the inspection,
the cooperation and assistance of Mr. M.E. Lassiter, and Ms. Jessica Griffey was helpful and appreciated.
This compliance evaluation inspection consisted of the following:
• Review of the permit;
• Review of the owner/facility information;
• Review of ORC logbooks, calibration documentation, Non -discharge wastewater monitoring
reports (NDMR), Non -discharge application reports (NDAR), Compliance Monitoring Forms
(G W-59) and;
• On -site inspection of treatment components and spray fields
The current permit was issued October 7, 2016 and expires on September 30, 2021. Currently, Mr.
Lassiter is designated ORC with Christopher Wheeler as backup ORC. Ms. Griffey is currently slated to
become ORC soon.
Components of the wastewater system appeared to be overall well -maintained and operational. Water in
the primary and storage lagoon was free of floating solids and plenty of freeboard was available in the
storage lagoon. The primary lagoon has a significant amount of solids and debris which reduces capacity.
D Q
,, North Carolina Department of Environmental Quality I Division of Water Resources
�/� Raleigh Regional office 1 3800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
Mr. Lassiter explained that in 2009 an issue with a peanut facility caused a large amount of debris to end
up in the pr amt ry lagoon. The Town should determine how much residual material is present and
draft a plan to address this issue (see deficiency below). The manual bar screen was in fair condition
and screenings are placed into trash receptacles. It was observed that the bar screen is largely ineffective
at catching debris due to the spacing of the bars. The Town has a metal working shop and can likely build
a better screen. This will reduce the amount of debris entering the primary pump station and the primary
lagoon. The influent flowmeter was last calibrated February 2019 by G2 Utilities. The irrigation fields
appeared to be in good condition with no evidence of ponding or runoff. The last representative soil
analyses were conducted in October 2018. The spray heads appeared to be in good condition, and portions
of the spray system were activated and appeared to have good spray patterns and coverage. The
chlorination equipment appeared to be in good condition. At the time of the inspection, the facility had
plenty of liquid hypochlorite available.
NDMR records for 2018-2019 were reviewed. The facility is monitoring the effluent as required but is
having the contract lab (Environment 1) analyze far more parameters than required by the permit resulting
in additional cost to the Town. During the inspection, the effluent sampling was discussed, and the Town
was encouraged to review Attachment A of the current permit to determine exactly which effluent
sampling parameters are required. Additionally, the town has not reported values for Total Residual
Chlorine (TRC) as required. Reviewing the Towns paperwork, it was observed that the Town is
monitoring TRC but it is unclear why these values have not been reported (see deficiency below). Several
random months of lab results were compared to NDMR forms with no discrepancies noted.
Monitoring wells 8 and 1 were observed and appeared to be in good condition. At the time of the
inspection both wells were locked and each well has signage indicating the well number. GW-59 reports
for 2018-2019 were reviewed and compared against the lab data. The current permit requires an annual
analysis for VOC's every October. The October 2018 GW-59 did not include these results as required,
however lab paperwork demonstrates wells were analyzed for VOC's. Please ensure this documentation
is included with GW-59's for future sampling events. This office has not received GW-59 reports for
the month of February 2019. The facility is not submitting certification forms (GW-59a) and lab results
with the GW-59 forms as required by the permit. Additionally, the current permit requires wells to be
sampled for Total Phosphorous (TP). The facility is currently not having the wells sampled for this
parameter. Please ensure well samples are analyzed for TP. Lastly, Monitoring Well 9 has exceedances of
groundwater standards for Chloride and Total Dissolved Solids for every month (except October 2018)
where data were reviewed. Please explain why these exceedances may be occurring in Monitoring Well 9
(see deficiencies below).
NDAR forms for 2018-2019 were reviewed. 12-month floating totals for spray Fields have not been
reported for June 2019. 12-month floating totals —Sum of this month's monthly loading and previous 11
month's monthly loading. Please ensure 12-month floating totals are included on every NDAR submitted.
The following permit condition deficiencies were noted during the August 15, 2019 compliance
inspection and records review:
III.Oaeration and Maintenance Requirements
Condition 1, which states that, "The facilities shall be properly maintained and operated at all times." The
primary lagoon has a significant amount of solids and debris which reduces capacity. Some of the
debris in the primary lagoon could be due to the large spacing in the bar screen. The Town should
determine how much residual material is present and draft a plan to address this issue.
TV. Monitoring and Reporting Re uirements
Condition 4,-which states that, "The Permittee shall monitor effluent from the subject facilities at the
frequencies and locations for the parameters specified in Attachment A." The facility is required to
sample for Total Residual Chlorine at each spray event. A records review indicates this parameter is not
being reported on form NDMR. It was however observed that the Town is taking this measurement.
Please ensure TRC is reported on form NDMR as required.
Condition I I. -Which states that, "Two copies of monitoring well sampling and analysis results shall be
submitted on a Compliance Monitoring Form (GW-59) along with attached copies of laboratory
analyses..... and one GW-59a certification form shall be submitted with each set of sampling results."
This office has not received GW-59 reports for the month of February 2019. The facility is not submitting
certification forms (GW-59a) and lab results with the GW-59 forms as required by the permit. The current
permit requires wells to be sampled for Total Phosphorous (TP). The facility is currently not having the
wells sampled for this parameter. Monitoring Well 9 has exceedances of groundwater standards for
Chloride and Total Dissolved Solids for every month (except October 2018) where data were reviewed.
Please explain why these exceedances may be occurring in Monitoring Well 9. Please ensure
monitoring well sampling documentation submitted to DWR includes laboratory analyses and the
GW-59a Certification Form. Please send February 2019 well sampling documentation (if available)
or explain why sampling was not conducted that month. Please ensure well samples are analyzed
for TP.
To prevent further action, please respond in writing to this office within 30 days upon your receipt
of this Notice of Deficiency regarding your plans or measures to be taken to address the indicated
deficiencies and other identified issues, if applicable. Please include in your response all corrective
actions already taken and a schedule for completion of any corrective actions not addressed.
If you have any questions about this inspection or this letter. please contact Rick Trone at
rick.trone_@ncdenr.gov or 919-7914200.
Rick Bolich, L.G.
Assistant Regional Supervisor
Water Quality Regional Operations
Raleigh Regional Office
Attachments: EPA Water Compliance Inspection Report
cc:
Central Files
RRO Files
_om Rance Inspection Report
Permit: Wt70004910 Effective: 10/07/16
Expiration: 09/30121
Owner: Town of Woodland
SOC: Effective:
Expiration:
Facility: Town of Woodland WWTF
County: Northampton
414 Jameson Ave
Region: Raleigh
Woodland NC 278970297
Contact Person: Marshall E. Lassiter
Title: ORC
Phone: 252-585-0411
Directions to Facility:
1-95 N to Rt 158 east towards Conway. Turn right onto Rt 258 south towards Woodland. Turn right on Rt 1557, lagoons and fields
are at the end of the road.
System Classifications: SI,
Primary ORC: Marshall E. Lassiter
Certification:
14887 Phone: 252-585-0411
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 08/15/2019 EntryTime: 10 00AM
Primary Inspector: Rick V Trone
Secondary Inspector(s):
Zachary Thomas
Reason for Inspection: Routine
Permit Inspection Type: Wastewater Irrigation
Facility Status: ❑ Compliant Not Compliant
Question Areas:
Miscellaneous Questions Treatment
Record Keeping Treatment Lagoons
Treatment Disinfection Wells
(see attachment summary)
Exit Time: 12.30PM
Phone: 919-791-4200
Inspection Type: Compliance Evaluation
Treatment Barscreen
End Use -Irrigation
Page 1 of 6
Permit; W00004910 Owner - Facility -.Town of Woodland
Inspection Date: 08115/2019 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
On August 15, 2019, Rick Trone, Zach Thomas, and Josh Brigham of the Raleigh Regional Office conducted a compliance
evaluation inspection of the wastewater irrigation system for Town of Woodland. The purpose of this Inspection was to
ensure compliance with the subject permit. During the Inspection, the cooperation and assistance of Mr. M.E. Lassiter, and
Ms. Jessica Griffey was helpful and appreciated.
This compliance evaluation inspection consisted of the following:
-Review of the permit;
-Review of the owner/facility information;
-Review of ORC logbooks, calibration documentation, Non -discharge wastewater monitoring reports (NDMR), Non -discharge
application reports (NDAR), Compliance Monitoring Fors (GW-59) and;
-On-site inspection of treatment components and spray fields
The current permit was issued October 7, 2016 and expires on September 30, 2021. Currently, Mr. Lassiter is designated
ORC with Christopher Wheeler as backup ORC. Ms. Griffey is currently slated to become ORC soon.
Components of the wastewater system appeared to be overall well -maintained and operational. Water In the primary and
storage lagoon was free of floating solids and plenty of freeboard was available in the storage lagoon. The primary lagoon has
a significant amount of sollds and debris which reduces capacity. Mr. Lassiter explained that In 2009 an Issue with a peanut
facility caused a large amount of debris to end up in the primary lagoon. The Town should determine how much residual
material Is present and draft a plan to address this issue (see deficiency below). The manual bar screen was In fair condition
and screenings are placed Into trash receptacles. It was observed that the bar screen is largely Ineffective at catching debris
due to the spacing of the bars. The Town has a metal working shop and can likely build a better screen. This will reduce the
amount of debris entering the primary pump station and the primary lagoon. The influent flowmeter was last calibrated
February 2019 by G2 Utilities. The irrigation fields appeared to be in good condition with no evidence of ponding or runoff.
The last representative soil analyses were conducted in October 2018. The spray heads appeared to be in good condition,
and portions of the spray system were activated and appeared to have good spray patterns and coverage. The chlorination
equipment appeared to be in good condition. At the time of the inspection, the facility had plenty of liquid hypochlorite
available.
NDMR records for 2018-2019 were reviewed. The facility is monitoring the effluent as required but is having the contract lab
(Environment 1) analyze far more parameters than required by the permit resulting in additional cost to the Town. During the
inspection, the effluent sampling was discussed, and the Town was encouraged to review Attachment A of the current permit
to determine exactly which effluent sampling parameters are required. Additionally, the town has not reported values for Total
Residual Chlorine (TRC) as required. Reviewing the Towns paperwork, it was observed that the Town is monitoring TRC but It
Is unclear why these values have not been reported (see deficiency below). Several random months of lab results were
compared to NDMR forms with no discrepancies noted.
Monitoring wells 8 and 1 were observed and appeared to be in good condition. Al the time of the inspection both wells were
locked and each well has signage indicating the well number. GW-59 reports for 2018-2019 were reviewed and compared
against the lab data. The current permit requires an annual analysis for VOC's every October. The October 2018 GW-59 did
not include these results as required, however lab paperwork demonstrates wells were analyzed for VOC's. Please ensure
this documentation Is included with GW-59's for future sampling events. This office has not received GW-59 reports for the
month of February 2019. The facility Is not submitting certification forms (GW-59a) and lab results with the GW-59 forms as
required by the permit. Additionally, the current permit requires wells to be sampled for Total Phosphorous (TP). The facility
is currently not having the wells sampled for this parameter, Please ensure well samples are analyzed for TP. Lastly,
Monitoring Well 9 has exceedances of groundwater standards for Chloride and Total Dissolved Solids for every month
(except October 2018) where data were reviewed. Please explain why these exceedances may be occurring in Monitoring
Well 9 (see deficiencies below).
NDAR forms for 2018-2019 were reviewed. 12-month floating totals for spray fields have not been reported for June 2019.
12-month floating totals=Sum of this month's monthly loading and previous 11 month's monthly loading. Please ensure
Page 2 of 6
Permit: W00004910 Owner - Facility:Town of woodland
Inspection auto: 081mo19 Inspection TYPO: Compliance Evaluation Reason tar Vlslt: Routine
12-month floating totals are included on every NDAR submitted.
The following permit condition deficiencies were noted during the August 15, 2019 compliance inspection and records review:
Ill. Operation and Maintenance Requirements
Condition 1, which states that, "The facilities shall be properly maintained and operated at all times." The primary lagoon has
a significant amount of solids and debris which reduces capacity. Some of the debris in the primary lagoon could be due to
the large spacing in the bar screen. The Town should determine how much residual material is present and draft a plan to
address this issue.
IV. Monitoring and Reporting Requirements
Condition 4, which states that, "The Permittee shall monitor effluent from the subject facilities at the frequencies and
locations for the parameters specified in Attachment A." The facility is required to sample for Total Residual Chlorine at each
spray event. A records review indicates this parameter is not being reported on form NDMR. It was however observed that
the Town is taking this measurement. Please ensure TRC is reported on form NDMR as required.
Condition 11, which states that, "Two copies of monitoring well sampling and analysis results shall be submitted an a
Compliance Monitoring Form (GW-59) along with attached copies of laboratory analyses.....and one GW-59a certification
form shall be submitted with each set of sampling results." This office has not received OW-59 reports for the month of
February 2019, The facility is not submitting certification forms (GW-59a) and lab results with the GW-59 forms as required
by the permit. The current permit requires wells to be sampled for Total Phosphorous (TP). The facility is currently not having
the wells sampled for this parameter. Monitoring Well 9 has exceedances of groundwater standards for Chloride and Total
Dissolved Solids for every month (except October 2018) where data were reviewed. Please explain why these exceedances
may be occurring in Monitoring Well 9. Please ensure monitoring well sampling documentation submitted to DWR Includes
laboratory analyses and the GW-59a Certification Form. Please send February 2019 well sampling documentation (if
available) or explain why sampling was not conducted that month. Please ensure well samples are analyzed for TP.
Page 3 of 6
Permit: W00004910 Owner -Facility: Town of Woodland
Inspection Date: 0811512019 Inspection Type: Compliance Evaluation Reason for Visit: Routine
TV09
Yes No NA NE
S ngle Family Drip
❑
Activated Sludge Spray, HR
0
Reuse (Quality)
❑
Activated Sludge Drip, LR
❑
Infiltration System
❑
Recycle/Reuse
❑
Lagoon Spray, LR
0
Single Family Spray, LR
0
Activated Sludge Spray, LR
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit? 0 0 1:111.
Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑
Comment: The bar screen is not listed in the permit. Bar screen is located at the main lift station.
Treatment Barscreen Yes No NA NE
Is it free of excessive debris? ■ ❑ ❑ ❑
Is disposal of screenings in compliance? M000
Are the bars spaced properly?
Is the unit in good condition? ON00
Comment: It was observed that the bar screen is larCleIV ineffective at Catching debris due to the spacing of
the bars. The Town has a metal workinci shop and can likely build a better screen. This will
reduce the amount of debris entering the primary pump station and the orimary lagoon
Treatment Disinfection
Yes No NA NE
Is the system working?
■ ❑ 0 ❑
Do the fecal coliform results indicate proper disinfection?
0El❑ ❑
Is there adequate detention time (> 30 minutes)?
M
Is the system properly maintained?
M
If gas, does the cylinder storage appear safe?
Is the fan In the chlorine feed room and storage area operable?
Is the chlorinator accessible?
0❑
If tablets, are tablets present?
a
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
0
If UV, are extra -UV bulbs available?
It UV, is the UV intensity adequate?
Page 4 of 6
Permit: WO0o04910 owner • Facility: Town of Woodland
Inspection Date: 08115/2019 Inspection Type: Compl ance Evaluation
Reason for Visit: Routine
# Is it a dual feed system?
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ■ ❑
If yes, then is there a Risk Management Plan on site? ❑ ❑ ■ ❑
If yes, then what is the EPA twelve digit ID Number? (1000- ❑ ❑ • o
If yes, then when was the RMP last updated?
Comment:
Record Keeping
Is a copy of current permit available?
1'tA--N€
Are monitoring reports present, NDMR?
■ ❑ ❑ ❑
NDAR?
• ❑ ❑ ❑
Are now rates less than of permitted flow?
■ ❑ ❑ ❑
Are (low rates less than of permitted flow?
• ❑ Cl ❑
Are application rates adhered to?
■ ❑ ❑ ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
■ O ❑ ❑
Are all samples analyzed for all required parameters?
■ ❑ ❑ ❑
Are there any 2L GW quality violations?
❑ ■ ❑ ❑
Is GW-59A certification form completed for facility?
■ O ❑ ❑
Is effluent sampled for same parameters as GW7
❑ ■ ❑ ❑
Do effluent concentrations exceed GW standards?
■ ❑ ❑ ❑
Are annual soil reports available?
❑ ❑ ■ ❑
# Are PAN records required?
■ ❑ ❑ ❑
# Did last soil report indicate a need for lime?
a ❑ • ❑
If so, has It been applied?
■ ❑ ❑
Are operational togs present?
❑■❑❑
Are lab sheets available for review?
■ ❑ ❑ ❑
Do lab sheets support data reported on NDMR?
■ ❑ ❑ ❑
Do lab sheets support data reported on GW-59s7
■ ❑ ❑ ❑
Are Operational and Maintenance records present?
■ ❑ ❑ ❑
Were Operational and Maintenance retards complete?
■❑
❑❑
Has permittee been free of public complaints in last 12 months?
■ ❑
❑ ❑
Is a copy of the SOC readily available?
■ ❑ ❑ ❑
No treatment units bypassed since last inspeclion7
❑❑■❑
Comment: See Summary,
0000
End Use-Irrl atlon
Are buffers adequate?
Yss No NA NE
Is the cover crap type specified in permit?
❑ ❑ ❑
■ ❑ ❑ ❑
Page 5 of 6
Permit: WQ0004910 Owner • Facility: Town of Woodland
Inspeetlan Date: 0811512019 Inspection Type -Compliance Evaluation
Reason for Visit: Routine
Is the crop cover acceptable?
0❑ 0 ❑
Is the site condition adequate?
N❑ ❑
Is the site free of runoff ! ponding?
Is the acreage specified in the permit being utilized?
Is the application equipment present?
Is the application equipment operational?
Is the disposal field free of limiting slopes?
11
Is access restricted and/or signs posted during active site use?
Are any supply wells within the CB?
■
Are any supply wells within 250' of the CB?
0
How close is the closest water supply well?
0 0 0
Is municipal water available in the area?
0 0 11 .
At Info only: floes the permit call for monitoring wells?
M
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
0 0 0
Are monitoring wells damaged?
0 0 ■
Comment:
Page 6 of 6