Loading...
HomeMy WebLinkAboutWQ0041023_Application (FTSE)_20190607State of North Carolina DW- Department of Environmental Quality .-R_ Division of Water Resources Division of Water Resources I5A NCAC 02T .0300 — FAST TRACK SE" -ER SYSTEM EXTENSION APPLICATION FT,% 04-I6 & SUPPORTING DOCUMENTATION Application Number: F� _ `(d+bcromplmcdbvDWR) All items must be completed or the application rill be returned I. APPLICANT INFORLATION: I. Applicant's name; Franklin County Schools (company, municipality, I-IOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑Genera! Partnership ❑Privately -Owned Public IJtilitv ❑ Federal ® State County ❑ Municipal ❑Other 3. Signature authority's name: Dr. Larry Webb per 15A NCAC 0„T..M0 z Title: Chiefof Auxiliary Serviceti C? t7 4. Applicant's mailing address; 53 West River Road fD Cii Louisburg State. NC Zip: 27549- UQ� C 0, Y' 5. Applicant's contact information: � Z � t Phone number (919) 496-2600 Email Address: larrv_webbO fcschools.net N . II. PROJECT INFORitiIATION: O � ?; I. Project name: Louisburg Hi di School Athletic Stadium �O n 2. Application/Project Status: ® Proposed (New Permit) ❑Existing Permit. Project If a modification, provide the existing permit number: WQ00_ and issued date: If new construction but part of master plan, provide the existing permit number: WQOO 3. County where project is located: Franklin 4. Approximate Coordinates (Decimal Degrees): Latitude: 36,111317 Longitude:-78.306723 5. Parcel [D (if applicable): (or Parcel ID to closest downstream sewer) M. CONSULTANT INFORMATION: 1. Professional Engineer: Kenneth A. Loring License Number: 23953 Firm: CLH Design P.A. Mailing address: 400 Regencv Forest Dr. #120 City: Cary Slate: NC Zip: 27518- Phone number: (919) 319-6716 Email Address- rpfeifer,ii clhdesignpa.com W. WASTEWATER TREATMENT FACILITY (W«'TF) INFORMATION: 1. Facility Name; Louisburg Water Reclamation Facility Permit Number: NCO0202031 Owner Name: Karl Pernell V. RECEIVING DOWNSTREAM SEWER INFORNIATION (if different than WWTF): I. Permit Number(s): WQQ005981 Downstream (Recei%ing) Sewer Size: 24 inch Syst_rm Wide C�Ilection System Parit Number q j•iTaM1i a (ej: 1VQCS Owner Name(s); FORM: FTA 04- l 6 Page I of 5 s NIL GENERAL REQUIREMENTS I . If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached'? ❑ Yeti []No ON -A 2. If the Applicant is a Developer of lots to be sold, has a ,,y cr's Operational Aerceme[tt I+ORM D V been attached'? ❑ Yeti [:]No ON. A 3. If the Applicant is a H wners' Asti ciution as an.QperatiortalAgreemeritF RM O been attached'! ❑ Yet ❑No ON -A 4 Origin of wastewater (check all that apply), ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Residential El Car Wash Leased ❑ Retail with food preparation/service ® School ❑ Motel and' :or Motels preschool day care ❑ Medical: dental - veterinary facilities ® Food and drink facilities ❑ Church ❑ Swimming Pool 'Clubhouse ❑ Businesses offices factories ❑ Nursing Home ❑ Swimming Pool: Filter Backwash ❑ Other (Explain in Attachment) 5- Nature of wastewater: 100 °ro Domestic. Commercial " o Commercial Industrial ( ee A NCAC 0..:T_.011 lQjo ) `GIs there a Pretreatment Program in effect? ❑ Yes ❑ No 6- Has a flow reduction been approved under _0A NCAC ?T ] 4 > ❑ Yes ®No If ves rovide a com of flow reduction aPProval letter 7. Summarize wastewater generated by project: Establishment Type (see Q21.0114�1�) Daily Design Flo"°•'' \o. of Units Flow Stadiums 5 gaf-seat 2500 12500 GPD gal' GPD gal' GPD gal/ GPD gal' GPD gal, GPD 7ourl 12500 GPD a See 1AXCAC 0_ :T .01 )d 2 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses: public access facilities located near high public use areas: and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G....42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14 j shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project; 12500 GPD (per 11A NC.,AC 02T .01.14) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why; ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORNI: FTA 04- 16 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA (if Applicable) - 02T .0305 & MDC Gravity Sewers): 1. Summarize gray ity sewer to be permitted: Size (inches) Length (feet) Material 8 57 PVC Section II & III of the IVIDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes fbr gravity sewer(s) Oversizing lines to meet minimum slope requirement is not alloi%ed and a violation of the NIDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & NIDC (Pum-P Stationse'Force Mains): COMPLETE FOR EACH PUIIIP STATION INCLUDED IN THIS PROJECT - Pump station number or name: 3. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -T 3, Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) taterial 6. Power reliability in accordance with 15A NCAC 02T .U305 r I : ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ .- Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15.000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T ,0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02-r .0305(h)(1)(C): It shall be demomstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: i-TA 04.16 Page 3 of 5 Ix- SETB_1CKS & SEPARATIONS — (02B .0200 & 152k NCAC 02T .0305(f)): 1, Does the project comply with all separations found in 1; �C 0 T L. fl 305 C 15A NCAC 02T.0305 f contains minimum separations that shall be ro%ided for sever systems_ Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) Water mains (vertical -water over sewer inefudina in benched trenches) '-� inches Water mains (horizontal) I g inches Reclaimed water lines (vertical - reclaimed over sewer) 10 feet Reclaimed water lines horizontal -reclaimed over sewer) Is inches 2 legit **Any private or public water supply source, including any wells, DVS-1 waters of Class I or Class II impounded reservoirs used as a source of drinkinu water **Waters classified WS (except WS-I or WS-V), B, SA. ORW, HQW, orSB from normal 100 feel hi+zh water for tide elevation) and wetlands (see item 1X.2) **Any other stream, lake, impoundment, or ground water lowering, 50 feet ditches and surface drainage An building foundation 10 tect Anv basement 5 feet To slo a of embankment or cuts of _' feet or more vertical hei+vht 10 feet Drainage systems and interce for drains 10 feet Any swimming ools 5 feet Final earth grade (vertical 10 Feet ---� 36 inches~ !U .rC \�L_02T .5_•{ contains alternatives where separations in 02T.0305 f cannot be achieved_ **Stream classifications can be identified using the Division's LN1 y1face kVate Cias,itic io s_neb F If noncompliance with 02T_0305 t or see Section X of thi, application 2. Dares the project Comply n ith separation requirements for wetlands" (50 feet of separation) See the Division's draft separation requirements for situations where separation cannot be meta es [I No ® N No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A N--A 02B .0200'? El ®N A This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require covera�-e authorization under a t04 Nationwide or mdividual permitscr401 Water Quality Certifications? ® Yes No Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0[0; c 6) (additional permiis. certitications)'? Yes El No Per 15A NCAC 02T.0105 c 6 , directly related environmental permits or certification applications are being prepared, have nt on issuance of d been applied for, or have been obtained. Issuance of this permit i, contingeependent permits (erosion and sedimentation control plans, stormwater manaement plans, etc.). 6. Does this project include any sewer collection lines that are deemed "ltigh-priority?" Per 15A NCAC 02T.0402. ••high -priority setiver- means --any aerial sewer, sewer contacting Surface waters, siphon. or sewer Positioned parallel to streambanks that iS subjct to erosion that undermines or deteriorates the sewer. ❑Yes ®No ❑NA Il•yes, include an attachment with details for each line, including type (aerial line, size• material, and location). High priority lines shall be inspected by the perntittee or its representative at least once every six -months and inspections documented per I5A NCAC 02T.0403(a)(5) or the perrnitee's individual System -Wide Collection permit. FOR,%I: FTA 04-16 Paso 4 nt, 1 X. CERTIFICATIONS: Does tite submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Pennittin , of Pum Stations and Force Mains latest version and the Gravit Sewer 1Vlinimum Desi ztt Criteria latest version as applicable? ❑ Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. A roval of the re uest is re aired rior to submittal of the Fust Truck A rivolication and su ortin documents. 2. Professional Engineer's Certification: 1, V'9" Jr,'f LDE4 Nor (Professional Engineer's name from Application Item II1.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best Of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: i�`''•(H GAJgQl/%� ti ?oQaF**ssio;�A_ - :1 :'Q ' SEA 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, tlry G!a!a t�yllr_ C (Signature Authority's name & t °i✓tt,-7 from Application Item I.3.) that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 1 3-: 5,6 1A and 143-215-6$, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: S 38 Date- FOR-M. FtA 04-16 Page 5 of 5 NC Dept of Fnvimnmental Quallty L IA ulvh0an of WAter Resource% State of North Carolina Department of Environmental Quality Raleigh Regional ofte Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Franklin County Schools Project Name for which flow is being requested: Louisburg High School Athletic Stadium More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Louisburg Water Reclamation_ Facility b. WWTP Facility Permit #: NC0020231 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 1.37 0 0.650 0.0125 0.650 48 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station (Name or Permit Number) No. NA (A) (B) (C) (D)=(B+C) (EHA-D) Design Obligated, Average Approx. Not Yet Total Current Firm Daily Flow** Current Tributary Flow Plus Capacity, * (Firm / pl), Avg. Daily Daily Flow. Obligated Available MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.O2(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is <0. Downstream Facility Name (Sewer): Louisburg Water Reclamation Facility Downstream Permit Number: NC0020231 Page I of 6 FTSE 10-18 f certify to the best of my knowledge that the addition of the volume o stewater t e permitted in this project has been evaluated along the route to the receiving wastewater tment fac' ty and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed ab a in Sections I and II plus all attached planning assessment addendums for which I am the responsible y. Signature of this form certifies that the receiving collection system or treatment works has adequap capA ity to transport Ad treat the proposed new wastewater. Title of Signing Official rasA Dare Page2of6 FTS1 10-18 PLANNING ASSESSMENT ADDENDUM WAA) Submit a planning assessment addendum for each pump station listed in Section lI where Available Capacity is < 0. Pump Station (Name or Number) -- Given that. a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for % and MGD of the Available Capacity (E) in Pump Station ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD per year; and that c_ A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in J ; and/or d. The following applies: "There are no pump stations between the project connection point and the WWTP. _ "All flow from Project connection point is gravies flow to WWTP. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143- 215.67(a) which prohibit the introduction of any waste in excess of the capacity of the waste disposal system. Signing c—sal. iJAJ6u ' � " / Dare Page 3 of 6 FryE 10-l8 CLH design, p.a. 400 Regency Forest Drive, Suite 120 Cary, North Carolina 27518 P: 919.319.6716 www.clhdesignpa.com Letter of Transmittal June 4, 2019 CLH Project Number: 16-145 kp.i • To: NCDWR nvironmental Quality Company: NCDWR - Raleigh Regional Office Address: 1628 Mail Service Center 201 City/State/Zip: Raleigh, NC 27699-1628 (919)-791-4200 tonal Offi Phone: Method: Snail Mail Subject: Louisburg HS Athletic Stadium - Sewer Extension Permits x Originals x Specifications Applications IPrints Reports Copy of Letter Submittals Other: Copies Date Description 2 06-05-19 Copies of FTA (1 original, 1 copy) 1 06-05-19 Check for $480 1 06-05-19 USE form i 06-05-19 USGS Map 1 06-05-19 Aerial of Property Additional Remarks: Hi, Please find the sewer extension permit submittal package for Louisburg High School Athletic Stadium. Please let me know if you have any questions or comments. Thanks! Renee Pfeifer Cc: File CLH design, p.a. NCDWQ Fast -Track Application Attachment— Project Narrative Project: Louisburg HS Athletic Stadium Owner: Franklin County Schools Engineer: CLH Desigm, PA Date: 5-June-2019 NCDept4f�nv}ronfie ntal Quality JUN Zo�9 �alelgb R°glOnal 011;�,e Franklin County Schools proposes to construct Louisburg High School Athletic Stadium along Allen Lane just west of the Louisburg High School campus (201 Allen Lane). Proposed construction encompasses track and field event facilities as well as auxiliary buildings such as concessions and bathrooms for the home and visitor teams. This site proposes a small run, approximately 60-Feet, of 8" private sewer. This main ties into an existing manhole that feeds to an existing 15" sewer main. FEMA FIRM # 3720280600K & #3720280500K dated April 16, 2013 indicates that the site is located within the limits of the 100-year good plain. The new track and field stadium will have 2500 seats. The anticipated average daily flow was estimated utilizing 5-gpd for each seat in the in the stadium. ADF = [5-gpd/seat x 2500 students] = 12,500-gpd The existing, downstream, sewer main serving the campus flows to the Louisburg Water Reclamation Facility (NC 00202031) which is owned and operated by the Karl Pernell. iiL PI L -K X X: F, LU w 0) LOUMMG HIGH SCHOOL ATHWW STADIUiM LO[A Mr. NC a TE NO MB6t WN PROJECT Na I&W5 Myf KUN COUNTY QUAD AM CLH DESIGN, PA Regency Park 400 Regency Forest Drive Suite 120 Cary, North Carolina Z7518 Phone: (919) 319-6716 Fax: (919) 319-7516 Deck, Erin M From: Renee C. Pfeifer <rpfeifer@clhdesignpa.com> Sent: Thursday, August 15, 2019 11:03 AM To: Deck, Erin M; Robinson, Jason Cc: Kenneth A. Loring; Larrywebb@fcschools.net; Hannah Banks Subject: RE: [External] RE: RE: RE: Louisburg HS Athletic Stadium - sewer extension • Externai.emaD.-Dd riar dlek links or open attachments urliess you verify. Send all suspfckous email as an-attac} l ent to Hi Erin, See below our responses in red. We look forward to receiving the permit. Thanks! Renee C. Pfeifer, PLA, ASLA Principal A touch of silver now with u yourhful abound..... ever mindful as the footprint which we leave upon this ground. 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919.319.6716, ext. 4016 Twitter / Linkedln / Facebook / www.clhdesignr)a.com Please consider the environment before printing E-mail Confidentiality Notice: The information contained in this transmission is confidential and may be subject to protection under the law. The message is intended for the sale use of the individual or entity to whom it is addressed. If you are not the intended recipient, you are notified that any use, distribution or copying of the message is strictly prohibited. If you received this transmission in error, please contact the sender immediately by replying to this e-mail and delete the material from any computer. From: Deck, Erin M <erin.deck@ncdenr.gov> Sent: Thursday, August 15, 2019 9:14 AM To: Renee C. Pfeifer <rpfeifer@clhdesignpa.com>; Robinson, Jason <jason.t.robinson@ncdenr.gov> Cc: Kenneth A. Loring <kloring@cIhdesignpa.com>; Larrywebb@fcschools.net Subject: RE: [External] RE: RE: RE: Louisburg HS Athletic Stadium - sewer extension Good Morning, I am in the process of reviewing the subject application and require additional information before I can continue to draft the permit. V.1: Receiving downstream sewer information. The permit number provided is the Town of Louisburg's Land Application of Residual Solids permit. Please provide the receiving sewer system permit number. Collections Permit # WQCS00113 IX.3 is marked "N/A" however the site is located in the Tar River basin and does have multiple streams depicted on the USGS Topo map. Please indicate either "yes" or "no" for this question. Please revise to "yes". If the applicant agrees, I can make the changes on the current application and you would not have to re -submit the application. Please make the changes on the current application. Thank you! Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 Email correspondence to and from this address is subject to the Nvrth Carolina Public Records Law and may be disclosed to third parties From: Renee C. Pfeifer [mail to:rpfeifer clhdesignpa.comj Sent: Tuesday, August 13, 2019 3:30 PM To: Robinson, Jason <Lson.t.robinson ncdenr.eov> Cc: Hannah Banks <HBanks@clhdesignpa.com>; Kenneth A. Loring <klorin dhdesi n a-com>; Duane Hutchins <dhutchins thinkboomeran .com>; Cashion, Ted <ted.cashion@ncdenr•eov>; Deck, Erin M <erin-deck@ncdenr.gov> Subject: [External] RE: RE: RE: Louisburg HS Athletic Stadium - sewer extension attachments un esFo. vie; h. Send all' - ":e al� $ a0 atta 'hieii #o. t :C'i- Great news. Thanks Jason! Renee C. Pfeifer, PLA, ASLA Principal A''i c.4 ..�. } my1 7 tt. r. �� �rt1 I ly l•....! �'-(1[•„ -1 SIIY��I �i-`t i't! }1 LI rl�l-. �tll Li4 L1411t1... &',u. l7i L':u�ru! oil i ficvL1 flf�,[ 4t l: tC7; 1l' tL'Cl ut' u;'4''; 1141� iZI-W1 . 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919.319.6716, ext. 4016 Twitter / Linkedln / Facebook /www.clhdesignpa,com Piea_e consid, r the P. ironment before printing E-mail Confidentiality Notice: The information contained in this transmission is confidential and may be subject to protection under the law. The message is intended for the sole use of the individual or ent,ty to whom it is addressed. If you are not the intended recipient, you are notified that any use, distribution or copying of the message is strictly prohibited. If you received this transmission in error, please contact the sender immediately by replying to this a mail and delete the material from any computer. From: Robinson, Jason <jason.t.robinson@ncdenr.eov> Sent: Tuesday, August 13, 2019 10:19 AM To: Renee C. Pfeifer <r feifer clhdesi n a.com> Cc: Hannah Banks <HBanks@clhdesienpa.com>; Kenneth A. Loring <klorineC�clhdesignpa_com>; Duane Hutchins <dhutchins thinkboomeran .com>; Cashion, Ted <ted.cashion ncdenr. ov>; Deck, Erin M <erin.deck(@ncdenr.eov> Subject: RE:RE: RE: Louisburg HS Athletic Stadium - sewer extension HI Renee, I think we're good. We hope to issue this permit by the end of this week, or early next week. Thanks, Jason ------------ Jason T. Robinson, P.E. Raleigh Regional Office Water Quality Regional Operations Division of Water Resources, DEQ 919-791-4200 "Subscribe to Collection System & Sewer Permitting Updates" E-mail correspondence to and from t&5 address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Renee C. Pfeifer <rpfeiferPclhdesignna.com> Sent: Monday, August 12, 2019 3:07 PM To: Robinson, Jason <jason.t.robinson@ncdenr.eov> Cc: Hannah Banks <HBanks clhdesi n a.com>; Kenneth A. Loring <klorin clhdesi n a.com>; Duane Hutchins <dhutchins thinkboomeran .com> Subject: [External] RE: RE: Louisburg HS Athletic Stadium - sewer extension • External email. Donot cliciciilsla or open atta rnents unlesuniess-yola verffy. Send,all-suspidfous erna - n attadimen71d e m n ov Hi Jason, I am just following up on my email below regarding the Louisburg HS Athletic Stadium. Please let me know if you find this acceptable. Thanks! Renee Renee C. Pfeifer, PLA, ASLA Principal A touch of silver noa, with a youthful abound...... ever mindful of the footprinr which we leove upon this ground. 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919.319.6716, ext. 4016 Twitter / Linkedln / Facebook / www.clhdesignpa.com Pleas¢ conAcr the environment before printing E-mail Confidentiality Notice: The information contained in thi3 transmission is confidential and may be subject to protection under the law. The message is intended for the sole use of the individual or entity to whom it is addressed. If you are not the intended recipient, you are notified that any use, distribution or copying of the message is strictly proh bited. If you received this transmission in error, pease contact the sender immed ately by replying to this e-mail and delete the material from any computer. From: Renee C. Pfeifer Sent: Wednesday, July 31, 2019 10:41 AM To: Robinson, Jason <'ason.t.robinson ncdenr. ov> Cc: Hannah Banks <HBanksC@clhdesit=_npa.com>; Kenneth A. Loring <klorin clhdesi n a-com>; Duane Hutchins <dhutchins thinkboomeran .com> Subject: RE: RE: Louisburg HS Athletic Stadium - sewer extension Importance: High Hi Jason, I know you are out of the office this week and I'm out next week, but I wanted to follow up on the sewer comments for the Louisburg HS Athletic Stadium. The 3 small buildings you reference on the Northeast side of the stadium are considered one single building according to the North Carolina Building Code. There is no intentional fire separation between plan areas, also note that PME systems and roof structure is shared across the entire building. The area underroof is treated as an Assembly occupancy for outdoor concession patron seating, much like a porch on a building. NCSBC 2018 requires occupied outdoor areas to be included within the building area.. I have attached a building code summary sheet that includes a rendering if the building, as well as the definition from the building code on the second page of this attached document. Can you please let me know if this satisfies your concern. We would like to keep the 4" sanitary sewer line as is. I will be checking emails periodically next week, but I have copied Hannah Banks and Ken Loring in our office on this if you should have any further questions. I look forward to receiving your approval and permit. Thanks Jason! Renee Renee C. Pfeifer, PLA, ASLA Principal ,4 t3ti{;) Q)rSiivl.�r:�iill! tVil'i'i L7 `'L�i�i+i Gi • i �il.....•. e:rr� ,., ,.,lV: leave z„il;_. „ . t,,,d, 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919.319.6716, ext. 4016 Twitter / Linkedln / Facebook / www.clhdesignpa.com Please consider the environment before pr ntmr E-mail Confidentiality Notice: The information contained irI this transmission is confidential and may be subject to protection under the law. The message is intended for the sole use of the individual or entity to whom It is addressed. If you are not the intended recipient, you are notified that any use, distribution or copying of the message is strictly prohibited. If you received this transmission in error, please contact the sender immediately by replying to this a - mail and delete the material From any computer. From: Robinson, Jason <iason.t.robinson@ncdenr.sov> Sent: Thursday, July 25, 2019 5:53 PM To: Renee C. Pfeifer <rpfeifer@clhdesienoa.com>; larrywebb@fcshools.net Cc: Deck, Erin M <erin.deck(cDncdenr.gov>; Cashion, Ted <ted.cashioniancdenr.gov>; Hannah Banks <HBanks clhdesi n a.com> Subject: RE: RE: Louisburg HS Athletic Stadium - sewer extension Hi Renee, 15A NCAC 02T .0303(2) states that a sewerline may be permitted by regulation (does not require a permit) if it serves a single -building.... But if a line serves more than one building, it must be permitted. So the application should be revised to include the line that serves the home buildings, starting at the point where the 2"d building ties -in. Also, since it has to be permitted, regulations require it to be a 6" line (since it's considered a private line, public lines have to be 8"). 1 did speak with our Central Office, who issues variances, and they did say they would be amenable to a variance to allow to keep this as a 4-inch. You'd have to submit a variance request that can be found here. Last I heard it was taking a month or two for variances to be issued, but you could talk to Christyn Fertenbaugh about that, she issues the variances. She's at 919-707-3625. So either 1. The application will needs to be revised to add the additional line and change it to a 6"... or 2. The application will need to be revised to add the additional line and keep it at a 4", but a variance request would need to be submitted. Please let us know how you plan to proceed. Thanks, Jason ------------ Jason T. Robinson, P.E. Raleigh Regional Office Water Quality Regional Operations Division of Water Resources, DEQ 919-791-4200 "Subscribe to Collection System & Sewer Permittin Updates** E-mail correspondence to and from this address may be subject to the North Carolina Public Records Low and may be disclosed to third parties. From: Renee C. Pfeifer <r feifer clhdesi n a.com> Sent: Wednesday, July 24, 2019 10:53 AM To: Robinson, Jason <iason.t.robinson@ncdenr.eov>; larrywebbefcshools.net Cc: Deck, Erin M <erin.deck@ncdenr.gov>; Cashion, Ted <ted.cashion@ncdenr.gov>; Hannah Banks <HBanks@clhdesienpa.com> Subject: [External] RE: Louisburg HS Athletic Stadium - sewer extension Importance: High unless you verify. Send all SU. picloti3�errta. ias a� rP�. Hi Jason, I have attached a markup of the proposed sewer lines for better clarification as well as the updated profile that shows the 57' of proposed sewer line. The application is correct the label on the profile was incorrect. Please let me know if you have any additional questions, We look forward to receiving your approval. Thanks! Renee Renee C. Pfeifer, PIA, ASLA Principal A tobCh oi s,.1ver;?niv iN:(fl t7 yi7i;rii I've. r,;xC/jrutLn Iht ili�ir��iir 4U.��!f!! iti'l �L7tiiVt iiOU,' tIN6 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919.319.6716, ext. 4016 Twitter / Linkedln / Facebook / www,clhdesignpa.com Please consider the environment before printing E-mail Confidentiality Notice: The information contained in this transmission is confidential and may be subject to protection under the law. The message is intended for the sole use of the individual or entity to whom it is addressed. If you are not the intended recipient, you are notified that any use, distribution or copying of the message is strictly prohibited, If you received this transmission in error, please contact the sender immediately by replying to this e-mail and delete the material from any computer. From: Robinson, Jason <Lason_t.robinson@ncdenr,gov> Sent: Monday, July 22, 2019 12:06 PM To: larrywebb@fcshools.net• Renee C. Pfeifer <r feifer clhdesi n a.com> Cc: Deck, Erin M <erjn,deck ncdenr, ov>; Cashion, Ted <ted.cashion@ncdenr,pov> Subject: Louisburg HS Athletic Stadium - sewer extension Mr. Loring & Mr. Webb. We are reviewing the referenced Sewer Extension application and have some questions. We've pulled the plans from the 401/404 application (see below). Please explain where the 57' of proposed sewer line is located in reference to the new stadium? Also explain where any "laterals" are located. From what we can tell from the plans, one line serves the small building on the Southwest side of the stadium. Another line appears to serve two or three small buildings on the northeast side of the stadium. Please confirm this. We may have further questions after we get a better understanding of where the sewerlines are. 0 Jason 7. Robinson, P.E. Raleigh Regional Office Water Quality Regional Operations Division of Water Resources, DEQ 919-791-4200 '*Subscribe to Collection Collection System & Sewer Permitting lJodates& Sewer Permitting lJgdates" E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 7 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL BUILDINGS (EXCEPT 1 AND 2-FAMILY DWELLINGS & TOWNHOUSES) GROSS BUILDING AREA TABLE FLOOR EXISTING (SO FT) NEW (SO FT) SUB -TOTAL Penthouse — — .... 5th Floor 4th Floor — — .... 3rd Floor 2nd Floor — Mezzanine ---- .._ 1st Floor 6110 - -- 6110 Basement — TOTAL 6110 — 6110 STORY DESCRIPTION (A) BLDG AREA (B) TABLE 506.2 C) AREA FOR (Di ALLOWABLE N0. AND USE PER STORY AREA 4 FRONTAGE AREA PER (ACTUAL) INCREASE 15 STORY OR UNLIMITED 2.3 i 1 ASSEMBLY A3 6110 6000 10050 1 I � em.uvuoa� mid 000n, — ,!-uxc• �„ . �«+ <, ota .�_,�.�;• t-; nova 11t1A ^ ` El aom Hoed ,ar ,a dsr uw ny �•-L` SI OGL) St OCLS 11 flfLl 2018 NORTH CAROLINA BUILDING CODE CHAPTER DEFINITIONS SECTION 202 DEFINITIONS ,1REA, BUILDING. The area included within surrounding, exterior ivalls (or exterior stalls and fire walls) +CCIUsive 61, vent shafts and vouris. Areas of the building not provided with surrounding, walls shall be included in the building, area if such areas are included within the horizontal projection of the rout' or flour above.