Loading...
HomeMy WebLinkAboutNCG050249_Inspection Report_20190819ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Consolidated Metco Inc Attention: Rick Linville 1821 Highway 19 South Bryson City, North Carolina 28713 NORTH CAROLINA Environmental Quality August 19, 2019 Subject: Compliance Evaluation Inspection Permit: NCG050000 Certificate of Coverage: NCG050249 Swain County, North Carolina Dear Mr. Linville: Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection I conducted at the subject facility on August 8, 2019. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact me at (828) 296-4500 or by email at Isaiah.reed@ncdenr.gov. Sincerel Isaiah Reed, CPSWQ, CEPSCI, MS CECI Environmental Specialist Land Quality Section Enclosure: Inspection Report eo"WK-Q�� North Carolina Department of Environmental Quality Division of Energy, Mineral and Land Resources Asheville Regional Office 12090 U.S. Highway 70 1 Swannanoa, North Carolina 28778 rvomn curourvn 828.296.4500 Compliance Inspection Report Permit: NGG050249 SOC: County: Swain Region: Asheville Contact Person: Rick Linville Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Effective: 06/01/18 Expiration: 05/31/23 Owner: Consolidated Metco Inc Effective: Expiration: Facility: Consolidated Metco Inc -Swain 1821 Hwy 19 S Inspection Date: 08/08/2019 Primary Inspector: Isaiah L Reed Secondary Inspector(s): Title: Entry Time: 02:OOPM Certification: Bryson City NC 28713 Phone: 704-226-5319 Phone: Exit Time: 03:30PM Phone: 828-296-4614 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Apparel/Printing/Paper/Leather/Rubber Stormwater Discharge CDC Facility Status: ❑ Compliant 0 Not Compliant Question Areas: Storm water (See attachment summary) Page 1 of 3 Permit: NCGO50249 Owner- Facility: Consolidated Metco Inc Inspection Date: 08/08/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On August 8, 2019 this facility was inspected for compliance. No major issues were noted during the inspection. Please see the below notes concerning the inspection: 1) The SWPPP did not correctly document the list of significant spills. The permittee is directed to modify that section of the SWPPP to be certified annually that no spills occurred. 2) The SWPPP was not reviewed and certified annually. The permittee is directed to review, update and certify the SWPPP on an annual basis as required by the NCGO50000 General Permit. 3) A qualitative monitoring report for both outfalls was not been filled out. The permittee is directed to fill out a monitoring report for each outfall. if you have any questions, please contact this office at (828) 296-4614 Page 2 of 3 Permit: NCGO50249 Owner. Facility: Consolidated Metco Inc Inspection Date: 08/08/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? N ❑ ❑ ❑ At Does the Plan include a General Location (USGS) map? 0 ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? E ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ 0 ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? 0 ❑ ❑ ❑ At Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? E ❑ ❑ ❑ # Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ At Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ 0 ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ 0 ❑ ❑ Comment: See summary for more information Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ❑ ❑ Comment: Qualitative monitoring only done for one of the two outfalls. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? N ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ 0 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ 0 ❑ ❑ Comment Page 3 of 3