Loading...
HomeMy WebLinkAboutNCG590016_Compliance Evaluation Inspection_20190814 STATF,F �� 4T ROY COOPER - r Governor MICHAEL S.REGAN ` Secretary $ *+ LINDA CULPEPPER NORTH CARauNA Director Environmental Quality August 14, 2019 Mr. Kevin Baughn, Town Manager Town of Madison 120 N. Market Street Madison, NC 27025 SUBJECT: Compliance Evaluation Inspection Madison Water Treatment Plant General Permit - Certificate of Coverage No. NCG590016 Rockingham County Dear Mr. Yates: On August 13, 2019,Jenny Graznak and Rebecca Chandler of this office met with Kevin Yates, Operator in Responsible Charge (ORC), to perform a Compliance Evaluation Inspection at the Madison Water Treatment Plant. This type of inspection consists of two basic parts: an in- office file review and an on-site inspection of the treatment facility. The attached EPA inspection form details the areas that were evaluated during this inspection. Please note the following specific observations from the inspection: 1) It is our understanding that this facility discharges infrequently due to a reduced amount of filter backwashing and increased efficiency. Furthermore, Ms. Graznak noted that operators have been creating discharge events in order to collect samples. Please be aware that you are only required to perform sampling during normal discharge events.You may state "No Flow" on the Discharge Monitoring Report as necessary. 2) During the inspection, Ms. Graznak observed a Town of Madison pump station and sewer line/manhole directly adjacent to the plant. She discussed with Mr. Yates the option of discharging the filter backwash or perhaps just the decant from the settling ponds into the town's sewer. Please keep us posted if this is a viable option for your Town. 3) This facility stopped adding Fluoride in June 2019. Therefore, Fluoride sampling is no longer required by the Permit. If you have any questions regarding the inspection or this report, please contact Ms. Graznak or me at (336) 776-9800. D EQ � North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1 450 Hanes Mill Road,Suite 300 1 Winston-Salem,North Carolina 27103 NOAn-icJwauNn i nwmnm of enm­wiwwv �� 336,776,9800 Sincerely, DocuSiig f c.ned by: "A. l ,ider 1 B4 E225 94EA... Lon ni er Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: EPA Water Compliance Inspection Report cc: Kevin Yates, Madison WTP (mad isonwtp@townof mad ison.or ) Central Files WSRO Files United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding(i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCG590016 111 12 I 19/08/13 I17 18 I S J 19 L G ] 201 I 211111 1 1 I I I I II I I I I I I I I I I I I 1 I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- 671 70 I I 71 I I 72 I r I 73 I I 174 751 I I I I I I I80 u ty Section B: Facility Data I I i Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 11:00AM 19/08/13 17/03/01 Madison WTP 403 Lindsey Bridge Rd Exit Time/Date Permit Expiration Date Madison NC 27025 12:30PM 19/08/13 19/07/31 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data J Kevin Yates/ORC/336-427-3971/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Robert F Scott,120 N Market St Madison NC 27025/Town Manager/336-427-0221/ No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit 0 Flow Measurement Operations&Maintenance 0 Records/Reports Self-Monitoring Program 0 Facility Site Review Effluent/Receiving Waters Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Jennifer F Graznak DocuSigned by: WSRO WQ//336-776-9800/ 8/14/2019 (J PJN I.A d4/t " �,� OD2D3CE3F1 B7456... Signature of Management Q A Reviewer LL� ocuSigned by: Agency/Office/Phone and Fax Numbers Date ,�, ? 1-5,dtc 8/14/2019 EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type (Cont.) 1 31 NCG590016 I11 121 19/08/13 117 18 ICI Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) 1) It is our understanding that this facility discharges infrequently due to a reduced amount of filter backwashing and increased efficiency. Furthermore, Ms. Graznak noted that operators have been creating discharge events in order to collect samples. Please be aware that you are only required to perform sampling during normal discharge events. You may state "No Flow" on the Discharge Monitoring Report as necessary. 2) During the inspection, Ms. Graznak observed a Town of Madison pump station and sewer line/manhole directly adjacent to the plant. She discussed with Mr. Yates the option of discharging the filter backwash or perhaps just the decant from the settling ponds into the town's sewer. Please keep us posted if this is a viable option for your Town. 3)This facility stopped adding Fluoride in June 2019. Therefore, Fluoride sampling is no longer required by the Permit. Page# 2 Permit: NCG590016 Owner-Facility: Madison WTP Inspection Date: 08/13/2019 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Total Residual Chlorine, PH, Turbidity are measured in house. All other parameters are sampled by Pace Analytical. They are using an aluminum based Coagulant. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ #Are there any special conditions for the permit? ❑ ❑ 0 ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The outfall was inspected and no issues were noted. Outfall is adjacent to sewer line, FYI Flow Measurement- Effluent Yes No NA NE #Is flow meter used for reporting? ❑ 0 ❑ ❑ Is flow meter calibrated annually? ❑ ❑ 0 ❑ Is the flow meter operational? ❑ ❑ 0 ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Flow volume is estimated. Lagoons Yes No NA NE Type of lagoons? #Number of lagoons in operation at time of visit? 2 Are lagoons operated in? #Is a re-circulation line present? ❑ ❑ ❑ Is lagoon free of excessive floating materials? ❑ ❑ ❑ Page# 3 Permit: NCG590016 Owner-Facility: Madison WTP Inspection Date: 08/13/2019 Inspection Type: Compliance Evaluation Lagoons Yes No NA NE #Are baffles between ponds or effluent baffles adjustable? ❑ ❑ 0 ❑ Are dike slopes clear of woody vegetation? 0 ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? ❑ ❑ ❑ ❑ Are dikes free of seepage? 0 ❑ ❑ ❑ Are dikes free of erosion? 0 ❑ ❑ ❑ Are dikes free of burrowing animals? 0 ❑ ❑ ❑ #Has the sludge blanket in the lagoon (s)been measured periodically in multiple 0 ❑ ❑ ❑ locations? #If excessive algae is present, has barley straw been used to help control the growth? ❑ 0 ❑ ❑ Is the lagoon surface free of weeds? ❑ 0 ❑ ❑ Is the lagoon free of short circuiting? 0 ❑ ❑ ❑ Comment: This facility discharges infrequently due to a reduced amount of filter backwashing and increased efficiency. Therefore, the lagoons do not contain much water. Residuals are scheduled to be pumped out by a land application company. Page# 4