Loading...
HomeMy WebLinkAbout20191084 Ver 1_17BP.5.R.88_Warren_135_Final_STR_20190814co m v O Ln M c L L 0 3: (,0 a o M O n 00 N cv O r j W \ o � � o � BENCHMARK TBM-4o BENCHTIE NAIL IN 18" OAK N 0 T E S-. TREE, 161 RIGHT OF -BL- STA. 15+33.00, EL. 219.02 // �� 1. ASSUMED LIVE LOAD = HL-93 OR ALTERNATE LOADING° 2. DESIGN FILL IS 1.0 FEET. WOODS // ���� / 3. THE EXISTING BRIDGE INDICATED ON THE PLANS IS FROM THE BEST INFORMATION AVAILABLE. SINCE THIS INFORMATION IS SHOWN FOR THE CONVENIENCE OF THE CONTRACTOR, THE CONTRACTOR SHALL HAVE NO CLAIM WHATSOEVER AGAINST THE DEPARTMENT OF TRANSPORTATION FOR ANY DELAYS OR ADDITIONAL COST INCURRED 0 / �P / BASED ON DIFFERENCES BETWEEN THE EXISTING BRIDGE SHOWN ON THE PLANS AND THE ACTUAL CONDITIONS AT THE PROJECT SITE. N Q + / 4e THE SURVEYOR SHALL CHECK THE LENGTH OF CULVERT BEFORE STAKING IT OUT TO MAKE CERTAIN THAT IT WILL PROPERLY TAKE CARE OF THE FILL. Z WOODS C / 5. THE EXISTING STRUCTURE CONSISTING OF 1 SPAN Cad 20'-8" WITH A TIMBER DECK ON STEEL I -BEAMS AND A CLEAR ROADWAY OF 17'-2" ON TIMBER CAPS ON RUBBLE MASONRY ABUTMENTS AND LOCATED AT THE POSTED SITE SHALL BE REMOVED. 6. REMOVAL OF THE EXISTING BRIDGE SHALL BE PERFORMED SO AS NOT TO ALLOW DEBRIS TO FALL INTO THE WATER. THE CONTRACTOR SHALL REMOVE THE EX STING Z PROPOSED GUARDRAIL / - BRIDGE AND SUBMIT PLANS FOR DEMOLITION IN ACCORDANCE WITH ARTICLE 402-2 OF THE STANDARD SPECIFICATIONS. (ROADWAY PAY ITEM AND DETAIL) (TYP. AS SHOWN) / / 7e THE BOTTOM OF FOOTING ELEVATIONS MAY BE LOWERED IN ORDER TO SATISFY BEARING CAPACITY AND MINIMUM EMBEDMENT REQUIREMENTS. RIP RAP CLASS II j STA.12+35.00 L 8. FOR PRECAST REINFORCED CONCRETE THREE SIDED CULVERT, SEE SPECIAL PROVISIONS. (ROADWAY ITEM) T(YPa) 9. THE PRECAST CULVERT SECTIONS AND WINGS SHALL BE DESIGNED TO HANDLE FULL DEPTH HYDROSTATIC PRESSURE IF WEEP HOLES ARE NOT UTILIZED. IF PROVIDED, WEEP HOLES SHALL BE LOCATED A MINIMUM HEIGHT OF 6 INCHES ABOVE THE NORMAL FLOW LINE AND HAVE A MAXIMUM SPACING OF 10 FEET. EXISTING BRIDGE 10. INASMUCH AS THE PAINT SYSTEM ON THE EXISTING STRUCTURAL STEEL CONTAINS LEAD, THE CONTRACTOR'S ATTENTION IS DIRECTED TO ARTICLE 107-1 OF THE PROPOSED 42'X10' - STANDARD SPECIFICATIONS. ANY COSTS RESULTING FROM COMPLIANCE WITH APPLICABLE STATE OR FEDERAL REGULATIONS PERTAINING TO HANDLING OF MATERIALS PRECAST THREE -SIDED / CONTAINING LEAD BASED PAINT SHALL BE INCLUDED IN THE BID PRICE FOR 'REMOVAL OF EXISTING STRUCTURE AT STATION 12+35.00 -L-." Fti CULVERT o / 11. FOR OTHER DESIGN DATA AND NOTES, SEE STANDARD NOTES SHEET. 0 r / 12. FOR EROSION CONTROL MEASURES,SEE EROSION CONTROL PLANS. 25 13. FOR CRANE SAFETY,SEE SPECIAL PROVISIONS / 14. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS. 15. FOR SUBMITTAL OF WORKING DRAWINGS, SEE SPECIAL PROVISIONS° Q) 16. FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS. VVOODS ,� �P� 17. FOR ASBESTOS ASSESSMENT FOR BRIDGE DEMOLITION AND RENOVATION ACTIVITIES, SEE SPECIAL PROVISIONS. WOODS 18. NO EQUIPMENT OR COMPONENTS WILL BE PLACED/STAGED IN FISHING CREEK. 19. THE BRIDGE WILL BE REMOVED FROM THE TOP DOWN, FIRST REMOVING THE ASPHALT WITH CONTAINMENT MEASURES IN PLACE TO PREVENT COMPONENTS OF THE BRIDGE FOR UTILITY INFORMATION, SEE UTILITY DECK FROM DROPPING INTO THE STREAM. THE METHOD OF CONTAINMENT WILL BE PROPOSED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER. THIS WILL BE i PLANS AND SPECIAL PROVISIONS• FOLLOWED BY REMOVAL OF THE RAIL, DECKING, GIRDERS, ETC. THE CONTRACTOR WILL THEN COMPLETELY ISOLATE THE MASONRY ABUTMENTS USING AN IMPERVIOUS DIKE LOCATION SKETCH IN THE STREAM TO ALLOW FOR COMPLETE REMOVAL OF THE ABUTMENTS. THE CONTRACTOR WILL INSTALL ADDITIONAL IMPERVIOUS DIKES IN THE STREAM AS NECESSARY TO ALLOW FOR CONSTRUCTION IN THE DRY OF THE CULVERT FOOTINGS AND FOR INSTALLATION OF THE CLASS II RIP RAP BANK STABILIZATION. ALL WORK IN THE STREAM AND ALONG THE STREAM BANKS MUST BE CONDUCTED IN THE DRY. ROADWAY DATA GRADE POINT ELEV. Cad STATION 12+35.00 -L- = 216.01 TOP OF FOOTING ELEV. Cad STATION 12+35.00 -L- = 204.00 ROADWAY SLOPES 2-1 HYDRAULIC DATA DESIGN DISCHARGE 2600 CFS FREQUENCY OF DESIGN FLOOD 2 YR. DESIGN HIGHWATER ELEV. 220.6 FT. DRAINAGE AREA 75.8 SO. MI. BASE DISCHARGE (0100) 11147 CFS BASE HIGHWATER ELEV. 229.3 FT. OVERTOPPING FLOOD DATA OVERTOPPING DISCHARGE 824 CFS FREQUENCY OF OVERTOPPING FLOOD <2 YR. OVERTOPPING FLOOD ELEV. 216.1 FT. * OVERTOPS AT STA. 12+00 -L- DRAWN BY. E, PHELPS DATE . 4/18 CHECKED BY- D. RUGGLES DATE . 4/18 DESIGN ENGINEER OF RECORD. D. RUGGLES DATE . 4/18 4c PROFILE ALONG CL OF CULVERT FOUNDATION NOTES-. 1. CARRY IN FOOTINGS FOR THE 3 SIDED CULVERT AT STATION 12+35.00 -L- AT LEAST 12"INTO ROCK WITH A MINIMUM THICKNESS AS SHOWN IN THE PLANS. TOTAL STRUCTURE QUANTITIES REMOVAL OF EXISTING STRUCTURE LUMP SUM 2 STA. 12+35.00 -L- ASBESTOS ASSESSMENT LUMP SUM CLASS A CONCRETE 61 CU, YDS. REINFORCING STEEL 7487 LBS. 42'X10' PRECAST REINFORCED CONCRETE THREE -SIDED LUMP SUM CULVERT @ STA. 12+35.00 -L- * INCLUDES CULVERT FOOTINGS AND GUARDRAIL FOOTINGS PROJECT NO. 17BPo5.Ro88 �,,•��,� cARoff%,, WARREN COUNTY 1''F 0 S /0 /�9 �''. SEAL _ STATION- 11725 o'`�NGINE`c�,• SHEET 1 OF 4 STATE OF NORTH CAROLINA SIGNATURE EXCLUDES DEPARTMENT OF TRANSPORTATION GUARDRAIL FUNCTION RALEIGH IF IMPACTED PRECAST DOCUMENT NOT CONSIDERED FINAL UNLESS ALL REINFORCED CONCRETE SIGNATURES COMPLETED Firm License No. C-1051 THREE -SIDED CULVERT 223 S. West St. 7 5 SKEW Suite 1100 Raleigh, NC 27603 T 919.380.8750 www.stewartinc.com NO. BY-. STEWART REVISIONS DATE-. NO. BY. DATE° SHEET NO. C-1 TOTAL SHEETS 5 F C N UAS I-1N-HLAUE WING FOOTING (TYPo) MnAMAIAV CTI I CI nF)C CULVERT SECTION NORMAL TO ROADWAY (ALONG SKEW) a o PLAN OF PRECAST THREE -SIDED CULVERT FOR SECTION A—A,SEE SHEET C-3o CAST —IN —PLACE WING FOOTING (TYPo) FNn FI P-\/OTTnN PRECAST OR CAST —IN —PLACE WING (TYPo) 9 ':KF 11 TPTON(; F PROJECT NO. 17BP.5.R.88 WARREN COUNTY STAT ON. 12+35.00 -L- SHEET 2 OF 4 m m SECTION A —A 52'-0" PLAN OF CONCRETE ARCH PRECAS CAST-IN-P WING CAST -IN -PLACE FOOTING 3„ PRECAST OR CAST -IN -PLACE WINGWALL OR THREE -SIDED CULVERT UNIT DETAIL "C" SEE DETAIL "C" -I F3 [-NON-SCOURABLE ROCK CAST -IN -PLACE WINGWALL FOOTING a SEE FOOTING oOoo��000O000Ooo��oo�` DETAIL oo� 000� oac� o0c] =ac---� oDo 0 N PRE, CULVERT I SECTION THRU WINGWALL CONTRACTOR SUBMITTAL OF WORKING DRAWINGS FOR PRECAST CULVERT SHAI I TN( -:I IINF WTN(.WAI I S_ DETAIL "C" tt n n 1 F� n 1 7, n r` 3,-6„ FOOTING DETAIL *ADJUST BOTTOM OF FOOTING ELEVATION AS REQUIRED TO PROVIDE l'-O" MINIMUM KEY INTO ROCK. KEYED FOOTING DETAIL SIDES OF ALL FOOTINGS SHALL BE IN CONTACT WITH NON-SCOURABLE ROCK FOR MINIMUM DIMENSION SHOWN JG *6C1 TOP & BOTTOM R RUNS) (2'-9" MIN LAP) (4) - #6C2 TOP & BOTTOM IN WINGWALL FOOTINGS (FIELD CUT AS REQUIRED) CAR �� o, SEAL 9�•' 11725 09 G I NE SIGNATURE EXCLUDES GUARDRAIL FUNCTION IF IMPACTED DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. WARREN STAT IONo SHEET 3 OF 4 17BPo5.Ro88 COUNTY 12+35.00 —L— m m F'SNlNc =R Et PLAN vl 55'-0" H CULVERT CENTER OF ARCH CULVERT SEE ROADWAY PLANS. GUARDRAIL ST LOCATIONS TO BE VERIFIED BY THE ENGINEER° 3" CLR. (TYPo) FOR BILL OF MATERIAL ONE FOOTING (2 REQU BAR NO. SIZE TYPE LENGTH WEIGHT Al 220 #4 STR 3'-6" 514 B1 48 #4 STR 19'-7" 628 REINFORCING STEEL LBS. 1142 CLASS A CONCRETE CU.YDS. 6.8 8 — #4 B1 2 6"CTSo = 3'-6„ 3" B.B.U. (TYPo) in SECTION B-B 3„ (TYPo) 0 0 #4 Al 2 6"CTSo NOTE- LAYOUT REINFORCING STEEL SHOULD BE CONDUCTED TO AVOID CONFLICT WITH ANCHOR BOLT LAYOUT FOR GUARDRAIL ATTACHMENT. AWN O0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 N I I 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 i � O i N 110 — #4 Al (�b 6" CTSo = 54'-6" FOOTING PLAN NOTE. MINIMUM LAP FOR B1 BARS IS 2'-0" B� D rI---- _ -II _u u——— — — — — —- 7" oz m cn = Z_ # Q0 Q m o @ FOR GUARDRAIL ANCHORAGE,SEE RDWY STD.862.03, 3" SHEET 7 OF 7. (TYP) F - NOTES EACH POST SHALL BE PROVIDED WITH A 1/2" X 1'-3" THREADED STEEL ROD WITH GALVANIZED NUTS AND WASHERS. INSTALL RODS ON POSTS BEFORE CONCRETE IS CAST. POSTS SHALL BE PLACED IN FINAL POSITION BEFORE CONCRETE IS CAST. PAYMENT FOR GUARDRAIL, POSTS, AND THREADED STEEL ROD WITH GALVANIZED NUTS AND WASHERS IS INCLUDED IN ROADWAY PAY ITEMS. SLAB REINFORCING STEEL MAY BE SHIFTED AS NECESSARY TO CLEAR GUARDRAIL POSTS.CARE SHOULD BE TAKEN TO KEEP THE SHIFTING OF REINFORCING STEEL TO A MINIMUM. TOP OF GUARDRAIL FOOTING TO MATCH PAVEMENT RIDING SURFACE. INSTALL JOINT SEALER BETWEEN SLAB AND PAVEMENT. NO ADDITIONAL PAYMENT WILL BE MADE FOR JOINT SEALER; THE COST OF THIS WORK TO BE DISTRIBUTED AMONG THE VARIOUS PAY ITEMS. ---------- � POST AND GUARDRAI[ ANCHOR ASSEMBLY i 7" SECTION C-C .CAR � s/o� o� °QoF�s� SEAL 11725 09 G R•RUGG�`�`�� SIGNATURE EXCLUDES GUARDRAIL FUNCTION IF IMPACTED DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED -r —1 2" 2" 1 i� INEUE; )5AKY ;IMUM OF 1/4" ) SECTION D-D PROJECT NO. WARREN STAT IONo SHEET 4 OF 4 17BPo5.Ro88 COUNTY 12+350OO —L— F O z U) r� c N L L L O U m O O O N O � j W DESIGN DATA- SPECIFICATIONS — — — — — — — — — — — — — — — — — A.A.S.H°T.O. (CURRENT) LIVE LOAD — — — — — — — — — — — — — — — — — — — — SEE PLANS IMPACT ALLOWANCE — — — — — — — — — — — — — — — — SEE A°A°S°H.T.O. STRESS IN EXTREME FIBER OF STRUCTURAL STEEL — AASHTO M270 GRADE 36 — — 20,000 LBS. PER SO. IN° — AASHTO M270 GRADE 50W — — 27,000 LBS. PER SO. IN. — AASHTO M270 GRADE 50 — — 27,000 LBS. PER SO. IN. REINFORCING STEEL IN TENSION — GRADE 60 — — — 24,000 LBS. PER SO. IN. CONCRETE IN COMPRESSION — — — — — — — — — — — — 1,200 LBS. PER SQ. INo CONCRETE IN SHEAR — — — — — — — — — — — — — — — — SEE A.A.S.H.T.O. STRUCTURAL TIMBER — TREATED OR UNTREATED EXTREME FIBER STRESS — — — 1,800 LBS. PER SO.IN. COMPRESSION PERPENDICULAR TO GRAIN OF TIMBER — — — — — 375 LBS. PER SO. IN. EQUIVALENT FLUID PRESSURE OF EARTH — — — — — 30 LBS. PER CUo FT. (MINIMUM) MATERIAL AND WORKMANSHIP - EXCEPT AS MAY OTHERWISE BE SPECIFIED ON PLANS OR IN THE SPECIAL PROVISIONS, ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE 2018 "STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES"OF THE N.C.DEPARTMENT OF TRANSPORTATION. STEEL SHEET PILING FOR PERMANENT OR TEMPORARY APPLICATIONS SHALL BE HOT ROLLED. CONCRETE - UNLESS OTHERWISE REQUIRED ON PLANS,CLASS A CONCRETE SHALL BE USED FOR ALL PORTIONS OF ALL STRUCTURES WITH THE EXCEPTION THAT- CLASS AA CONCRETE SHALL BE USED IN BRIDGE SUPERSTRUCTURES, ABUTMENT BACKWALLS, AND APPROACH SLABS, AND CLASS B CONCRETE SHALL BE USED FOR SLOPE PROTECTION AND RIP RAP. CONCRETE CHAMFERS - UNLESS OTHERWISE NOTED ON THE PLANS,ALL EXPOSED CORNERS ON STRUCTURES SHALL BE CHAMFERED 3/4"WITH THE FOLLOWING EXCEPTIONS - TOP CORNERS OF CURBS MAY BE ROUNDED TO 11/2"RADIUS WHICH IS BUILT INTO CURB FORMS, CORNERS OF TRANSVERSE FLOOR EXPANSION JOINTS SHALL BE ROUNDED WITH A 1/4"FINISHING TOOL UNLESS OTHERWISE REQUIRED ON PLANS,AND CORNERS OF EXPANSION JOINTS IN THE ROADWAY FACES AND TOPS OF CURBS AND SIDEWALKS SHALL BE ROUNDED TO A 1/4"RADIUS WITH A FINISHING STONE OR TOOL UNLESS OTHERWISE REQUIRED ON PLANS. DOWELS - DOWELS WHEN INDICATED ON PLANS AS FOR CULVERT EXTENSIONS,SHALL BE EMBEDDED AT LEAST 12"INTO THE OLD CONCRETE AND GROUTED INTO PLACE WITH 1-2 CEMENT MORTAR. STANDARD NOTES ALLOWANCE FOR DEAD LOAD DEFLECTIONS SETTLEMENTS ETC. IN CASTING SUPERSTRUCTURES - BRIDGES SHALL BE BUILT ON THE GRADE OR VERTICAL CURVE SHOWN ON PLANS. SLABS, CURBS AND PARAPETS SHALL CONFORM TO THE GRADE OR CURVE. ALL DIMENSIONS WHICH ARE GIVEN IN SECTION AND ARE AFFECTED BY DEAD LOAD DEFLECTIONS ARE DIMENSIONS AT CENTER LINE OF BEARING UNLESS OTHERWISE NOTED ON PLANS. IN SETTING FORMS FOR STEEL BEAM BRIDGES AND PRESTRESSED CONCRETE GIRDER BRIDGES, ADJUSTMENTS SHALL BE MADE DUE TO THE DEAD LOAD DEFLECTIONS FOR THE ELEVATIONS SHOWN. WHERE BLOCKS ARE SHOWN OVER BEAMS FOR BUILDING UP TO THE SLAB, THE VERTICAL DIMENSIONS OF THE BLOCKS SHALL BE ADJUSTED BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTIONS, VERTICAL CURVE ORDINATE, AND ACTUAL BEAM CAMBER. WHERE BOTTOM OF SLAB IS IN LINE WITH BOTTOM OF TOP FLANGES, DEPTH OF SLAB BETWEEN BEARINGS SHALL BE ADJUSTED TO COMPENSATE FOR DEAD LOAD DEFLECTION,VERTICAL CURVE ORDINATE,AND ACTUAL BEAM CAMBER. IN SETTING FALSEWORK AND FORMS FOR REINFORCED CONCRETE SPANS, AN ALLOWANCE SHALL BE MADE FOR DEAD LOAD DEFLECTIONS, SETTLEMENT OF FALSEWORK, AND PERMANENT CAMBER WHICH SHALL BE PROVIDED FOR IN ADDITION TO THE ELEVATIONS SHOWN. AFTER REMOVAL OF THE FALSEWORK, THE FINISHED STRUCTURES SHALL CONFORM TO THE PROFILE AND ELEVATIONS SHOWN ON THE PLANS AND CONSTRUCTION ELEVATIONS FURNISHED BY THE ENGINEER° DETAILED DRAWINGS FOR FALSEWORK OR FORMS FOR BRIDGE SUPERSTRUCTURE AND ANY STRUCTURE OR PARTS OF A STRUCTURE AS NOTED ON THE PLANS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL BEFORE CONSTRUCTION OF THE FALSEWORK OR FORMS IS STARTED. REINFORCING STEEL - ALL REINFORCING STEEL SHALL BE DEFORMED. DIMENSIONS RELATIVE TO PLACEMENT OF REINFORCING ARE TO CENTERS OF BARS UNLESS OTHERWISE INDICATED IN THE PLANS. DIMENSIONS ON BAR DETAILS ARE TO CENTERS OF BARS OR ARE OUT TO OUT AS INDICATED ON PLANS. WIRE BAR SUPPORTS SHALL BE PROVIDED FOR REINFORCING STEEL WHERE INDICATED ON THE PLANS. WHEN BAR SUPPORT PIECES ARE PLACED IN CONTINUOUS LINES, THEY SHALL BE SO PLACED THAT THE ENDS OF THE SUPPORTING WIRES SHALL BE LAPPED TO LOCK LEGS ON ADJOINING PIECES. STRUCTURAL STEEL - AT THE CONTRACTOR'S OPTION, HE MAY SUBSTITUTE 7/8" 0 SHEAR STUDS FOR THE %q"O STUDS SPECIFIED ON THE PLANS. THIS SUBSTITUTION SHALL BE MADE AT THE RATE OF 3 — 7/8" 0 STUDS FOR 4 — 3/q" 0 STUDS, AND STUD SPACING CHANGES SHALL BE MADE AS NECESSARY TO PROVIDE THE SAME EQUIVALENT NUMBER OF 7/8"0 STUDS ALONG THE BEAM AS SHOWN FOR 3/q" O STUDS BASED ON THE RATIO OF 3 — 7/8" 0 STUDS FOR 4 — %q"O STUDS. STUDS OF THE LENGTH SPECIFIED ON THE PLANS MUST BE PROVIDED. THE MAXIMUM SPACING SHALL BE 2'-0". EXCEPT AT THE INTERIOR SUPPORTS OF CONTINUOUS BEAMS WHERE THE COVER PLATE IS IN CONTACT WITH BEARING PLATE, THE CONTRACTOR MAY, AT HIS OPTION, SUBSTITUTE FOR THE COVER PLATES DESIGNATED ON THE PLANS COVER PLATES OF THE EQUIVALENT AREA PROVIDED THESE PLATES ARE AT LEAST 5/6"IN THICKNESS AND DO NOT EXCEED A WIDTH EQUAL TO THE FLANGE WIDTH LESS 2"OR A THICKNESS EQUAL TO 2 TIMES THE FLANGE THICKNESS° THE SIZE OF FILLET WELDS SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENT ANSI/AASHTO/AWS "BRIDGE WELDING CODE". ELECTROSLAG WELDING WILL NOT BE PERMITTED° WITH THE SOLE EXCEPTION OF EDGES AT SURFACES WHICH BEAR ON OTHER SURFACES,ALL SHARP EDGES AND ENDS OF SHAPES AND PLATES SHALL BE SLIGHTLY ROUNDED BY SUITABLE MEANS TO A RADIUS OF APPROXIMATELY 11/16INCH OR EQUIVALENT FLAT SURFACE AT A SUITABLE ANGLE PRIOR TO PAINTING, GALVANIZING, OR METALLIZING° HANDRAILS AND POSTS - METAL STANDARDS AND FACES OF THE CONCRETE END POSTS FOR THE METAL RAIL SHALL BE SET NORMAL TO THE GRADE OF THE CURB, UNLESS OTHERWISE SHOWN ON PLANS. THE METAL RAIL AND TOPS OF CONCRETE POSTS USED WITH THE ALUMINUM RAIL SHALL BE BUILT PARALLEL TO THE GRADE OF THE CURB. METAL HANDRAILS SHALL BE IN ACCORDANCE WITH THE PLANS. RAILS SHALL BE AS MANUFACTURED FOR BRIDGE RAILING. CASTINGS SHALL BE OF A UNIFORM APPEARANCE. FINS AND OTHER DEFORMATIONS RESULTING FROM CASTING OR OTHERWISE SHALL BE REMOVED IN A MANNER SO THAT A UNIFORM COLORING OF THE COMPLETED CASTING SHALL BE OBTAINED. CASTINGS WITH DISCOLORATIONS OR OF NON —UNIFORM COLORING WILL NOT BE ACCEPTED. CERTIFIED MILL REPORTS ARE REQUIRED FOR METAL RAILS AND POSTS. SPECIAL NOTES - GENERALLY, IN CASE OF DISCREPANCY, THIS STANDARD SHEET OF NOTES SHALL GOVERN OVER THE SPECIFICATIONS, BUT THE REMAINDER OF THE PLANS SHALL GOVERN OVER NOTES HEREON, AND SPECIAL PROVISIONS SHALL GOVERN OVER ALL. SEE SPECIFICATIONS ARTICLE 105-4. PROJECT NO. WARREN STAT ION - 17BPo5.Ro88 COUNTY 12+35.00 —L— REV. 6-16-95 EEM (,i) R G W REV. 5-7-03 RWW (,/) J T E REV. 10-1-11 MAA (,/) GM REV. 8-16-99 RWW Q) L E S REV. 5-1-06 TLA W) GM REV. 12-17 MAA P) T H C STD. NO. SN